Lithonia Lighting Security Lighting Installation Instructions
Lithonia Lighting Security Lighting offers reliable dusk-to-dawn illumination for outdoor areas. Designed for simple installation on walls or poles, it features a compact fluorescent lamp for energy-efficient operation. The fixture's durable construction and adjustable photocell ensure long-lasting performance and customized light control. Enhance safety and security around your property with this dependable lighting solution.
Advertisement
Advertisement
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
IMPOR T ANT SAFETY INSTRUCTIONS
INSTALLATION
INSTRUCTIONS
TDD65L 120
Dusk-to-Dawn Area Light
Compact Fluorescent
WARNING: FAILURE TO FOLLOW THESE INSTRUCTIONS AND WARNINGS MAY RE-
SULT IN DEATH, INJURY, OR SIGNIFICANT PROPERTY DAMAGE - For your protection, read and follow these warnings and instructions carefully before installing or maintaining this fixture. These instructions do not attempt to cover all installation and maintenance situations. If you do not understand these instructions or additional information is required, contact Lithonia Lighting or your local Lithonia
Lighting distributor.
WARNING: RISK OF ELECTRIC SHOCK - To avoid electric shock, serious injury, or death, be certain that all electrical power is disconnected from the supply branch circuit conductors before installing or maintaining this fixture. This product must be installed and maintained in accordance with the applicable installation codes by a person familiar with the construction and operation of the product and the hazards involved.
WARNING: RISK OF PERSONAL INJURY - This product may have sharp edges. Wear gloves to prevent cuts or abrasions when removing from carton, handling, installing and maintaining this product. Lithonia Lighting assumes no responsibility for claims arising out of improper or careless installation or handling of this product.
RISK OF FIRE - Lamps are hot. Keep combustible material away from hot parts.
TROUBLESHOOTING
If this fixture fails to operate properly, check to make sure:
• The correct lamp is properly installed.
• The fixture is wired correctly.
• The lamp is not faulty.
• The fixture is grounded correctly.
• The line voltage at the fixture is correct.
CAUTION
Observe lamp manufacturer's recommendations and restrictions on lamp operations, including but not limited to ballast type, burning position, and cycling. Use ANSI rated lamps only.
Maintenance : For optimum performance, periodically clean reflector and lens with a soft, damp cloth.
Important : DO NOT use abrasive materials, glass cleaner or other solvents on lens or paint. Use only mild, soapy water.
RISK OF FIRE - Observe lamp manufacturer’s warnings, recommendations and restrictions on lamp operation and maintenance.
LOCATION: Select a location on a structurally sound wall or pole 8 to 24 feet off the ground. The fixture should be located at least 18” below any overhangs or other structural details. Installation of the fixture in any other position than what is indicated within the supplied instructions will void all warranties.
IMPORTANT SAFETY
INSTRUCTIONS
• This fixture must be wired in accordance with the National Electrical Code and applicable local codes and ordinances.
Figure 1
• Do not install a damaged fixture.
MOUNTING
1. Slide lower arm portion (6) into mounting bracket (5).
Securely mount this lower section arm assembly to the pole or wall using the 4 lag screws and washers provided (4). Route the supply wire through arm and secure per the National Electrical Code and all applicable local codes.
2. Mount the upper section of the arm (2) to the fixture head using the 3 1/8” bracket and 5/16” screws (1).
Install the green ground screw to the underside of the mounting strap.
3. After making wiring connections (described below), slide the upper portion of the arm (2) over the lower portion being careful to align the holes in both arms.
Secure the 2 pieces using the 2 nuts, 4 washers, and
3/16-24 round head bolts.
• Proper grounding is required to ensure personal safety. Be certain green lead from the fixture is connected to supply ground.
WIRING
• Use code compliant connectors for all electrical connections.
Caution: Check that voltage is compatible with fixture ballast (120V). Use code compliant connectors (not provided) for all electrical connections. Connect the black fixture lead to the black supply lead; white fixture lead to the white supply lead; the supply ground lead to the green ground screw (provided) on arm
• ALL work should be done by a qualified bracket.
electrician.
LENS, LAMP, and PHOTOCELL INSTALLATION
• WARNING: NEVER connect or disconnect any component while power supply is
1. Install the reflector/lens assembly (9). Secure with the two 5/8” screws
(8) to the corresponding holes in the socket support bracket. See fig. 1.
engaged.
DELIVERY : Upon receipt of fixture and accessories (packed separately), thoroughly inspect for any freight damage. All damage should be re-
DISCONTINUED
you have received the correct merchandise.
firmly seated.
9)
2. Prior to installing the lamp (10) in the fixture, check to make sure that all power is disconnected. Ensure that the lamp source and wattage corresponds with the fixture label. To properly seat the lamp into the fixture, screw the lamp securely into the socket. Back the lamp out one to two turns and then screw the lamp back into the socket, making sure
SAVE THESE INSTRUCTIONS
1999 © Acuity Lighting Group, Inc., Rev B 2/11/09
RJ521315CF INST SHT TDDCFL
Download
Advertisement