LEDJ LEDJ556A Spectra Flood 18HEX10 PRO Exterior Fixture Manual
Add to My manuals16 Pages
The Ledj LEDJ556A Spectra Flood 18HEX10 PRO is a professional exterior fixture with 18 x 10W six-color LEDs, delivering a smooth wash of color. Controllable via the on-board menu system or DMX, it's ideal for illuminating signage, facades, landscapes, and more.
advertisement
Spectra Flood 18HEX10 PRO
Exterior Fixture
User Manual
Order code: LEDJ556A
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE YOUR INITIAL START-UP!
• Before your initial start-up, please make sure that there is no damage caused during transportation.
• Should there be any damage, consult your dealer and do not use the equipment.
• To maintain the equipment in good working condition and to ensure safe operation, it is necessary for the user to follow the safety instructions and warning notes written in this manual.
• Please note that damages caused by user modifications to this equipment are not subject to warranty.
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modification to the equipment.
• Never let the power cable come into contact with other cables. Handle the power cable and all mains voltage connections with particular caution!
• Never remove warning or informative labels from the unit.
• Do not open the equipment and do not modify the unit.
• Do not connect this equipment to a dimmer pack.
• Do not switch the equipment on and off in short intervals, as this will reduce the system’s life.
• Do not expose to flammable sources, liquids or gases.
• Always disconnect the power from the mains when equipment is not in use or before cleaning! Only handle the power-cable by the plug. Never pull out the plug by pulling the power-cable.
• Make sure that the available mains supply voltage is between 100~240V AC, 50/60Hz.
• Make sure that the power cable is never crimped or damaged. Check the equipment and the power cable periodically.
• If the equipment is dropped or damaged, disconnect the mains power supply immediately and have a qualified engineer inspect the equipment before operating again.
• If your product fails to function correctly, stop use immediately. Pack the unit securely (preferably in the original packing material), and return it to your Prolight dealer for service.
• Only use fuses of same type and rating.
• Repairs, servicing and power connection must only be carried out by a qualified technician. THIS UNIT CONTAINS
NO USER SERVICEABLE PARTS.
• This lighting fixture is for professional use only - it is not designed for or suitable for household use. The product must be installed by a qualified technician in accordance with local territory regulations. The safety of the installation is the responsibility of the installer. The fixture presents risks of severe injury or death due to fire hazards, electric shock and falls.
• Warning! Risk Group 2 LED product according to
EN 62471. Do not view the light output with optical instruments or any device that may concentrate the beam.
• WARRANTY: One year from date of purchase.
OPERATING DETERMINATIONS
If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc.
Do not endanger your own safety and the safety of others!
Incorrect installation or use can cause serious damage to people and/or property.
Please note: These fixtures are intended for stage lighting and entertainment applications only, and are not intended for extended periods of use, including but not limited to house-light, industrial or architectural applications and should only be operated with short duty cycles.
www.prolight.co.uk
Spectra Flood 18HEX10 PRO User Manual
2
Product overview & technical specifications
Spectra Flood 18HEX10 PRO Exterior Fixture
The exterior Spectra Flood 18HEX10 PRO features 18 x 10W six-colour LEDs, delivering a smooth wash of colour, ranging from intense, rich saturated hues through to pastel shades. Controllable via the on-board 4 button LED menu system for auto, static colour or master/slave modes, with the option of DMX control for larger installations. Signage and facade features can be illuminated along with landscapes, and the simple daisy chain connection of power and DMX means that installation time and cost is reduced. The heavy-duty alloy enclosure is convection cooled for silent running and features TRUE1 and 5-Pin DMX inputs and outputs to facilitate a problem-free, rental ready connection.
IP65
RATED
• 18 x 10W six-colour LEDs (RGBWAUV)
• Beam angle: 40°
• 1,770 Lux @ 2m (full on)
• Refresh rate: 1kHz, 3kHz, 6kHz or 12kHz selectable
• DMX channels: 1/6/7/8 or 12 selectable
• Static colour, colour change, colour fade, auto and master/slave modes
• 0 - 100% dimming
• 4 dimming curves with two dimming response times: Linear, square law, inverse square law and S-curve
• Variable strobe
• Bracket allows for multiple rigging or floor standing applications
• Quick release omega clamp included
• 4 push button menu with LED display
• Menu lock prevents unwanted operation
• PowerCON TRUE1 compatible Seetronic input/output
• IP rated 5-Pin XLR input/output
• Convection cooled
B
W
A
UV
40° - Lux
FULL ON
R
G
7080
1748
3284
740
3880
2200
N/A
Specifications Spectra Flood 18HEX10 PRO
Power consumption 85W
Power supply
Dimensions
100~240V, 50/60Hz
270 x 320 x 150mm
IP rating
Weight
Order code
IP65
4.4kg
LEDJ556A
1770
437
821
185
970
550
N/A
787
193
365
81
430
243
N/A
443
108
204
45
243
138
N/A
282
70
130
30
154
88
N/A
40°
320mm
0m 1m 2m
150mm
3m 4m 5m www.prolight.co.uk
Spectra Flood 18HEX10 PRO User Manual
3
Technical specifications
03 05 07
02 02
01 04 06 08 01
01 - Hanging bracket
02 - Hanging bracket adjustment knobs
03 - IP rated power input www.prolight.co.uk
04 - IP rated power output
05 - LED display
06 - Function buttons
07 - IP rated DMX input
08 - IP rated DMX output
Spectra Flood 18HEX10 PRO
In the box:
1 x fixture &
1 x power cable
User Manual
4
Operating instructions
d - - -
S L A u d 0 0 1 d 5 1 2
1 - C h
6 - C h
7 - C h
8 - C h
1 2 C h
DMX address/channel mode y E S
N O
Master/slave mode
MENU
A U Й O y E S
N O
Auto modes p r o
P r 0 1
P r 0 2
P r 1 6
C o 0 0
C o 4 1
S P 0 1
S p f L
Built-in static colour
F S 0 0 ~ F 5 9 9
Built-in programs
C o L r r 0 0 0 g 0 0 0 b 0 0 0 u 0 0 0
A 0 0 0
I 0 0 0 r 2 5 5 g 2 5 5 b 2 5 5 u 2 5 5
A 2 5 5
I 2 5 5
Dimming mode www.prolight.co.uk
Spectra Flood 18HEX10 PRO User Manual
5
S e t
C u r d I s p f r e q f a I L
L o C
ј
F A C t
C u - 1
C u - 2
C u - 3
C u - 4
Dimming curve
F A S t
S L O
Dimming speed selection
F - 0 1
F - 0 3
F - 0 6
F - 1 2
PWM Frequency
O F F
H O L d
DMX fail
0 N
O F F
Display lock y E S
N O
Factory settings
I n F o
V e r V x . x Software version n o r t E n p - r t -
- H I -
Temperature detection
L I f e x x x h Fixture hours www.prolight.co.uk
Spectra Flood 18HEX10 PRO User Manual
6
Operating instructions
DMX mode:
To select the DMX address, press the “MENU” button on the rear of the unit to show
d---
on the
LED display. Then press “ SETUP” and
d001
will appear. Now use the “UP” and “DOWN” buttons to select the DMX address between 001-512.
To exit out of any of the above options, press the “MENU” button.
DMX channel mode:
Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating a show. In this mode you will be able to control each individual trait of the fixture and each fixture independently. To access the DMX channel mode, press the “MENU” button on the rear of the unit to show
d001
on the LED display. Now press the “SETUP” button to show
--CH
on the
LED display and use the “UP” and “DOWN” buttons to select between 1, 6, 7, 8 and 12 channels.
To exit out of any of the above options, press the “MENU” button.
1 channel mode:
Channel Value
000-015
016-020
021-025
026-030
031-035
036-040
041-045
046-050
051-055
056-060
061-065
1
066-070
071-075
076-080
081-085
086-090
091-095
096-100
101-105
106-110
111-115
116-120
121-125
126-130
131-135
Function
No function
Red
Flame Red
Deep Orange
Amber
Deep Yellow
Medium
Yellow
Lime Green
Chartreuse Green
Bright Green
Lawn Green
Green
Neon Green
Slime Green
Harlequin Green
Spring Green
Seafoam Green
Light Blue
Medium Blue
Blue
Deep Blue
Deep Purple
Purple
Dark Violet
Colour preset
Channel Value
136-140
141-145
146-150
151-155
156-160
161-165
1
166-170
171-175
176-180
181-185
186-190
191-195
196-200
201-205
206-210
211-215
216-255
Function
Violet
Magenta
Fuchsia Pink
Hot Pink
Crimson
Scarlet Red
Candy Red
White
Pastel Pink
Pastel Baby Pink
Mint Green
Pastel Mint Green
Pastel Blue
Pastel Baby Blue
Ice White
Amber
UV
Colour preset www.prolight.co.uk
Spectra Flood 18HEX10 PRO User Manual
7
6 channel mode:
2
3
4
5
6
Channel Value
1
Function
000-255 Red (0-100%)
000-255 Green (0-100%)
000-255 Blue (0-100%)
000-255 White (0-100%)
000-255 Amber (0-100%)
000-255 UV (0-100%)
7 channel mode:
5
6
7
2
3
4
Channel Value
1
Function
000-255 Master Dimmer (0-100%)
000-255 Red (0-100%)
000-255 Green (0-100%)
000-255 Blue (0-100%)
000-255 White (0-100%)
000-255 Amber (0-100%)
000-255 UV (0-100%)
8 channel mode:
6
7
8
3
4
5
Channel Value
1
Function
000-255 Master Dimmer (0-100%)
2
000-010 No function
011-255 Speed (slow-fast)
000-255 Red (0-100%)
000-255 Green (0-100%)
000-255 Blue (0-100%)
000-255 White (0-100%)
000-255 Amber (0-100%)
000-255 UV (0-100%)
Operating instructions
12 channel mode:
3
141-145
146-150
151-155
156-160
161-165
166-170
171-175
176-180
181-185
186-190
091-095
096-100
101-105
106-110
111-115
116-120
121-125
126-130
131-135
136-140
Channel Value
1 000-255
000-010
2
011-255
000-015
016-020
021-025
026-030
031-035
036-040
041-045
046-050
051-055
056-060
061-065
066-070
071-075
076-080
081-085
086-090
Spring Green
Seafoam Green
Light Blue
Medium Blue
Blue
Deep Blue
Deep Purple
Purple
Dark Violet
Violet
Magenta
Fuchsia Pink
Hot Pink
Crimson
Scarlet Red
Candy Red
White
Pastel Pink
Pastel Baby Pink
Mint Green
Function
Master Dimmer (0-100%)
No function
Strobe (slow-fast)
No function
Red
Flame Red
Deep Orange
Amber
Deep Yellow
Medium Yellow
Yellow
Lime Green
Chartreuse Green
Bright Green
Lawn Green
Green
Neon Green
Slime Green
Harlequin Green
Colour preset www.prolight.co.uk
Spectra Flood 18HEX10 PRO User Manual
8
Operating instructions
12 channel mode (cont):
7
8
9
5
6
10
11
Channel Value
191-195
196-200
3(cont.)
201-205
206-210
211-215
216-255
000-015
016-031
032-047
4
048-063
064-079
080-095
096-111
112-127
128-143
144-159
160-175
176-191
192-207
12
208-223
224-239
240-255
000-255
000-255
000-255
000-255
000-255
000-255
000-255
000-036
037-073
074-110
111-147
148-184
185-221
222-255
Jump 3
Jump 4
Jump 5
Jump 6
Jump 7
Jump 8
Fade 1
Fade 2
Fade 3
Fade 4
Function
Pastel Mint Green
Pastel Blue
Pastel Baby Blue
Ice White
Amber
UV
No function
Jump 1
Jump 2
Fade 5
Fade 6
Fade 7
Speed (slow-fast)
Red (0-100%)
Green (0-100%)
Blue (0-100%)
White (0-100%)
Amber (0-100%)
UV (0-100%)
No function
Dimmer Fast
Dimmer Slow
Linear Curve
Square Curve
Inv. Square curve
S-Type Curve
Colour preset
Programs
Hold value for 2 seconds.
www.prolight.co.uk
Spectra Flood 18HEX10 PRO User Manual
9
Operating instructions
Slave mode:
To set the slave unit, press the “MENU” button on the rear of the unit to show
SLav
on the LED display, press “ SETUP” then us the “ UP” and “ DOWN” buttons to select
yEs
or
NO
. To exit out of any of the above options, press the “MENU” button.
Auto mode:
To access auto mode, press the “ MENU ” button on the rear of the unit to show AU Й O use the “UP” and
“DOWN” buttons to choose yES or NO on the LED display. The unit will now run through its built-in programs. To exit out of any of the above options, press the “ MENU ” button.
Built-in programs:
To select a built-in static colour, press the “ MENU ” button on the rear of the unit until it shows press the “ SETUP ” button to show
Pro
Pr01 then press “ SETUP ” again to show CoOO.
Use the “UP” and
“DOWN” buttons to select the static colour required CoOO ~ Co41.
Press the “ SETUP ” button again to confirm the setting and use the “UP” and “DOWN” buttons to select the flash speed F500 ~ F599 .
To access the built-in programs, press the “ MENU ” button on the rear of the unit until it shows Pro on the LED display. Press “ SETUP ” and use the “UP” and “DOWN” buttons to choose the required program Pr02 ~ Pr16 . Press the “ SETUP ” button to confirm the setting and use the “UP” and
“DOWN” buttons to choose the speed SP01 ~ SPfL . Press the “ SETUP ” button again to confirm the setting and use the “UP” and “DOWN” buttons to select the flash speed F500 ~ F599 . To exit out of any of the above options, press the “ MENU ” button.
Colour mix mode:
To access the colour mix mode press “MENU” until
CoLr
shows on the LED display. Now press the
“SETUP” button and use the “UP” and “DOWN” buttons to select either red (r) green (
9
), blue (
b
), White
( u ) , Amber ( A ) and UV ( l ) . Now use the “UP” and “DOWN” buttons to select the brightness between
r.000
~
r.255
.
Value: 000 - 255 (000 = low brightness, 255 = high brightness)
To exit out of any of the above options, press the “MENU” button.
Dimming Curve Settings
To enter the dimming curve settings, press the “MENU” button on the rear of the unit to show
Set.
Then use the “ UP” and “ DOWN” buttons to select
Cur.
Use the “ UP” and “ DOWN” buttons to select one of four dimming curves.
Cu-1
(linear)
Cu-2
( square law)
Cu-3
(inv square law)
Cu-4
(S-Curve
).
To exit out of any of the above options, press the “MENU” button.
Dimming Speed Settings
To enter the dimming speed settings, press the “MENU” button on the rear of the unit to show
Set.
Then press the “SETUP” button on the rear of the unit to show
Cur.
Then use the “ UP” and “ DOWN” buttons and select
disp.
Press the “ SETUP ” button then use the “ UP” and “ DOWN” buttons to select
Fast
or
sLo.
To exit out of any of the above options, press the “MENU” button.
www.prolight.co.uk
Spectra Flood 18HEX10 PRO User Manual
10
Frequency Settings
To enter the dimming speed settings, press the “MENU” button on the rear of the unit to show
Set.
Then press the “SETUP” button on the rear of the unit to show
freq
, press “ SETUP” again then use the “ UP” and “ DOWN” buttons to select between
f-01, f-03, F-06
and
F-12.
To exit out of any of the above options, press the “MENU” button.
Lock Settings
If a menu selection has not been made for 30 seconds, the screen will lock automatically. Press “MENU” and “SETUP” for 3 seconds to unlock. In the unlocked state, press “MENU” and “SETUP” at the same time to lock quickly. To access the lock setting, press “MENU” button on the rear of the unit to show
SEt.
Press “ SETUP” and use the “ UP” and “ DOWN” buttons to select
LOCј
. Then press “ SETUP” and use the “ UP” and “ DOWN” buttons to select
ON
or
OFF.
To exit out of any of the above options, press the “MENU” button.
Factory reset:
Press the “MENU” button to show
SEt,
Press “ SETUP” and use the “UP” and “DOWN” buttons to find
FACt.
Press “ ENTER” then use the “UP” and “DOWN” buttons to select
yEs
or
NO.
The unit will now have reset to factory settings.
Information:
Press the “MENU” button to show
Info
press “SETUP” and use the “UP” and “DOWN” buttons to find
ver
(software version),
tEnp
(temperature information) and
LIfE
(fixture hours). Press “SETUP” in any of these menus and the relevant information will be displayed. Please see below chart for temperature information codes.
Nor When shown on the unit, temperature detection is normal.
-rt-
-Hi-
When shown on the unit, the unit temperature is too low and will automatically go into protection mode.
When shown on the unit, the unit temperature is too high and will automatically go into protection mode.
www.prolight.co.uk
Spectra Flood 18HEX10 PRO User Manual
11
DMX setup
Setting the DMX address:
The DMX mode enables the use of a universal DMX controller. Each fixture requires a “start address” from 1- 512. A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address. For example, a fixture that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100, would read data from channels: 100,101,102,103,104,105 and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in the chain starts at 107.
DMX 512:
DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions form the controller to the fixture.
DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT”
XLR terminals located on all DMX fixtures (most controllers only have a data “out” terminal).
DMX linking:
DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller, as long as all fixtures and the controller are DMX compliant.
To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the
DMX addressing. For example; a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a
DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.
Also remember that DMX cable must be daisy chained and cannot be split.
DATA cable (DMX cable) requirements (for DMX operation):
This fixture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit.
Further DMX cables can be purchased from all good sound and lighting suppliers or Pro Light Concepts dealers.
Please quote:
LEDJ 1m Interior -
Exterior DMX cable
LEDJ 1m Exterior
DMX cable
LEDJ 2m Exterior
DMX cable
LEDJ 5m Exterior
DMX cable
LEDJ 10m Exterior
DMX cable
Order code: LEDJ91 Order code: LEDJ141 Order code: LEDJ142 Order code: LEDJ143 Order code: LEDJ144
LEDJ 1m Exterior
Power cable
LEDJ 2m Exterior
Power cable
LEDJ 5m Exterior
Power cable
LEDJ 10m Exterior
Power cable
LEDJ Spectra Series
End Cap Set
Order code: LEDJ146 Order code: LEDJ147 Order code: LEDJ148 Order code: LEDJ149 Order code: LEDJ93 www.prolight.co.uk
Spectra Flood 18HEX10 PRO User Manual
12
DMX setup
Notice:
Be sure to follow the diagrams below when making your own cables.
Do not connect the cables shield conductor to the ground lug or allow the shield conductor to come in contact with the XLRs outer casing. Grounding the shield could cause a short circuit and erratic behaviour.
Pin Configuration
3-Pin 5-Pin
Pin 1 - Ground
–
–
Pin 2 - Negative
Pin 3 - Positive
Pin 4 - N/C
Pin 5 - N/C
3-Pin XLR female
DMX 512
3-Pin XLR output
1
2
3
GROUND
DMX +
DMX –
DMX 512
3-Pin XLR input
3
1
2
3-Pin XLR male
DMX 512
5-Pin XLR output
DMX 512
5-Pin XLR input
1 2
5 4
3
DMX –
N/C
GROUND
DMX +
N/C
3
2
1
4 5
Line termination:
When longer runs of cable are used, you may need to use a terminator on the last unit to avoid erratic behaviour.
Using a cable terminator will decrease the possibilities of erratic behaviour.
(3-pin - Order ref: CABL90,
5-pin - Order ref: CABL89)
3-Pin
1
3
2
1 ground
3 hot
5-Pin XLR male
2 cold 2 cold
3 hot
1 ground
5-Pin XLR female
1 ground
2 cold
3 hot
5 N/C
4 N/C
5 N/C
4 N/C
3 hot
1 ground
2 cold
Termination reduces signal transmission problems and interference. It is always advisable to connect a DMX terminal, (resistance 120
Ohm 1/4W) between pin 2
(DMX-) and pin 3 (DMX+) of the last fixture.
5-Pin
1
2
3
4
5
5-pin XLR DMX connectors:
Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-pin XLR fixtures may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a
3-pin line a cable adaptor must be used. The diagram below details the correct cable conversion.
5-pin XLR (female)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
3-pin XLR (male)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
3-pin XLR (female)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
5-pin XLR (male)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C www.prolight.co.uk
Spectra Flood 18HEX10 PRO User Manual
13
Multiple fixture power linking
Power linking:
This fixture provides power linking via the power output on the rear allowing multiple units to be connected together. The maximum number of fixtures that can be connected is 20 fixtures @ 240V or 10 fixtures @ 120V (including the first fixture). After the maximum number of fixtures are connected a new power run will need to be started.
Please note: Caution should be used when power linking other fixtures to the Spectra Flood 18HEX10 as the power consumption of other fixtures will vary. Fixtures fitted with lamps often require 2/3 times more current on startup, these may require their own power source.
www.prolight.co.uk
Spectra Flood 18HEX10 PRO User Manual
14
WEEE notice
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries with separate collection systems)
This marking shown on the product or its literature, indicates that it should not be disposed of with other household wastes at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take this item for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes for disposal.
www.prolight.co.uk
Spectra Flood 18HEX10 PRO User Manual
15
www.prolight.co.uk
Spectra Flood 18HEX10 PRO User Manual
16
advertisement