Spectra Flood 18HEX10 PRO

Exterior Fixture

User Manual

Order code: LEDJ556A

Safety advice

WARNING

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL

CAREFULLY BEFORE YOUR INITIAL START-UP!

• Before your initial start-up, please make sure that there is no damage caused during transportation.

• Should there be any damage, consult your dealer and do not use the equipment.

• To maintain the equipment in good working condition and to ensure safe operation, it is necessary for the user to follow the safety instructions and warning notes written in this manual.

• Please note that damages caused by user modifications to this equipment are not subject to warranty.

CAUTION!

TAKE CARE USING

THIS EQUIPMENT!

HIGH VOLTAGE-RISK

OF ELECTRIC SHOCK!!

IMPORTANT:

The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modification to the equipment.

• Never let the power cable come into contact with other cables. Handle the power cable and all mains voltage connections with particular caution!

• Never remove warning or informative labels from the unit.

• Do not open the equipment and do not modify the unit.

• Do not connect this equipment to a dimmer pack.

• Do not switch the equipment on and off in short intervals, as this will reduce the system’s life.

• Do not expose to flammable sources, liquids or gases.

• Always disconnect the power from the mains when equipment is not in use or before cleaning! Only handle the power-cable by the plug. Never pull out the plug by pulling the power-cable.

• Make sure that the available mains supply voltage is between 100~240V AC, 50/60Hz.

• Make sure that the power cable is never crimped or damaged. Check the equipment and the power cable periodically.

• If the equipment is dropped or damaged, disconnect the mains power supply immediately and have a qualified engineer inspect the equipment before operating again.

• If your product fails to function correctly, stop use immediately. Pack the unit securely (preferably in the original packing material), and return it to your Prolight dealer for service.

• Only use fuses of same type and rating.

• Repairs, servicing and power connection must only be carried out by a qualified technician. THIS UNIT CONTAINS

NO USER SERVICEABLE PARTS.

• This lighting fixture is for professional use only - it is not designed for or suitable for household use. The product must be installed by a qualified technician in accordance with local territory regulations. The safety of the installation is the responsibility of the installer. The fixture presents risks of severe injury or death due to fire hazards, electric shock and falls.

• Warning! Risk Group 2 LED product according to

EN 62471. Do not view the light output with optical instruments or any device that may concentrate the beam.

• WARRANTY: One year from date of purchase.

OPERATING DETERMINATIONS

If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc.

Do not endanger your own safety and the safety of others!

Incorrect installation or use can cause serious damage to people and/or property.

Please note: These fixtures are intended for stage lighting and entertainment applications only, and are not intended for extended periods of use, including but not limited to house-light, industrial or architectural applications and should only be operated with short duty cycles.

www.prolight.co.uk

Spectra Flood 18HEX10 PRO User Manual

2

Product overview & technical specifications

Spectra Flood 18HEX10 PRO Exterior Fixture

The exterior Spectra Flood 18HEX10 PRO features 18 x 10W six-colour LEDs, delivering a smooth wash of colour, ranging from intense, rich saturated hues through to pastel shades. Controllable via the on-board 4 button LED menu system for auto, static colour or master/slave modes, with the option of DMX control for larger installations. Signage and facade features can be illuminated along with landscapes, and the simple daisy chain connection of power and DMX means that installation time and cost is reduced. The heavy-duty alloy enclosure is convection cooled for silent running and features TRUE1 and 5-Pin DMX inputs and outputs to facilitate a problem-free, rental ready connection.

IP65

RATED

• 18 x 10W six-colour LEDs (RGBWAUV)

• Beam angle: 40°

• 1,770 Lux @ 2m (full on)

• Refresh rate: 1kHz, 3kHz, 6kHz or 12kHz selectable

• DMX channels: 1/6/7/8 or 12 selectable

• Static colour, colour change, colour fade, auto and master/slave modes

• 0 - 100% dimming

• 4 dimming curves with two dimming response times: Linear, square law, inverse square law and S-curve

• Variable strobe

• Bracket allows for multiple rigging or floor standing applications

• Quick release omega clamp included

• 4 push button menu with LED display

• Menu lock prevents unwanted operation

• PowerCON TRUE1 compatible Seetronic input/output

• IP rated 5-Pin XLR input/output

• Convection cooled

B

W

A

UV

40° - Lux

FULL ON

R

G

7080

1748

3284

740

3880

2200

N/A

Specifications Spectra Flood 18HEX10 PRO

Power consumption 85W

Power supply

Dimensions

100~240V, 50/60Hz

270 x 320 x 150mm

IP rating

Weight

Order code

IP65

4.4kg

LEDJ556A

1770

437

821

185

970

550

N/A

787

193

365

81

430

243

N/A

443

108

204

45

243

138

N/A

282

70

130

30

154

88

N/A

40°

320mm

0m 1m 2m

150mm

3m 4m 5m www.prolight.co.uk

Spectra Flood 18HEX10 PRO User Manual

3

Technical specifications

03 05 07

02 02

01 04 06 08 01

01 - Hanging bracket

02 - Hanging bracket adjustment knobs

03 - IP rated power input www.prolight.co.uk

04 - IP rated power output

05 - LED display

06 - Function buttons

07 - IP rated DMX input

08 - IP rated DMX output

Spectra Flood 18HEX10 PRO

In the box:

1 x fixture &

1 x power cable

User Manual

4

Operating instructions

d - - -

S L A u d 0 0 1 d 5 1 2

1 - C h

6 - C h

7 - C h

8 - C h

1 2 C h

DMX address/channel mode y E S

N O

Master/slave mode

MENU

A U Й O y E S

N O

Auto modes p r o

P r 0 1

P r 0 2

P r 1 6

C o 0 0

C o 4 1

S P 0 1

S p f L

Built-in static colour

F S 0 0 ~ F 5 9 9

Built-in programs

C o L r r 0 0 0 g 0 0 0 b 0 0 0 u 0 0 0

A 0 0 0

I 0 0 0 r 2 5 5 g 2 5 5 b 2 5 5 u 2 5 5

A 2 5 5

I 2 5 5

Dimming mode www.prolight.co.uk

Spectra Flood 18HEX10 PRO User Manual

5

S e t

C u r d I s p f r e q f a I L

L o C

ј

F A C t

C u - 1

C u - 2

C u - 3

C u - 4

Dimming curve

F A S t

S L O

Dimming speed selection

F - 0 1

F - 0 3

F - 0 6

F - 1 2

PWM Frequency

O F F

H O L d

DMX fail

0 N

O F F

Display lock y E S

N O

Factory settings

I n F o

V e r V x . x Software version n o r t E n p - r t -

- H I -

Temperature detection

L I f e x x x h Fixture hours www.prolight.co.uk

Spectra Flood 18HEX10 PRO User Manual

6

Operating instructions

DMX mode:

To select the DMX address, press the “MENU” button on the rear of the unit to show

d---

on the

LED display. Then press “ SETUP” and

d001

will appear. Now use the “UP” and “DOWN” buttons to select the DMX address between 001-512.

To exit out of any of the above options, press the “MENU” button.

DMX channel mode:

Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating a show. In this mode you will be able to control each individual trait of the fixture and each fixture independently. To access the DMX channel mode, press the “MENU” button on the rear of the unit to show

d001

on the LED display. Now press the “SETUP” button to show

--CH

on the

LED display and use the “UP” and “DOWN” buttons to select between 1, 6, 7, 8 and 12 channels.

To exit out of any of the above options, press the “MENU” button.

1 channel mode:

Channel Value

000-015

016-020

021-025

026-030

031-035

036-040

041-045

046-050

051-055

056-060

061-065

1

066-070

071-075

076-080

081-085

086-090

091-095

096-100

101-105

106-110

111-115

116-120

121-125

126-130

131-135

Function

No function

Red

Flame Red

Deep Orange

Amber

Deep Yellow

Medium

Yellow

Lime Green

Chartreuse Green

Bright Green

Lawn Green

Green

Neon Green

Slime Green

Harlequin Green

Spring Green

Seafoam Green

Light Blue

Medium Blue

Blue

Deep Blue

Deep Purple

Purple

Dark Violet

Colour preset

Channel Value

136-140

141-145

146-150

151-155

156-160

161-165

1

166-170

171-175

176-180

181-185

186-190

191-195

196-200

201-205

206-210

211-215

216-255

Function

Violet

Magenta

Fuchsia Pink

Hot Pink

Crimson

Scarlet Red

Candy Red

White

Pastel Pink

Pastel Baby Pink

Mint Green

Pastel Mint Green

Pastel Blue

Pastel Baby Blue

Ice White

Amber

UV

Colour preset www.prolight.co.uk

Spectra Flood 18HEX10 PRO User Manual

7

6 channel mode:

2

3

4

5

6

Channel Value

1

Function

000-255 Red (0-100%)

000-255 Green (0-100%)

000-255 Blue (0-100%)

000-255 White (0-100%)

000-255 Amber (0-100%)

000-255 UV (0-100%)

7 channel mode:

5

6

7

2

3

4

Channel Value

1

Function

000-255 Master Dimmer (0-100%)

000-255 Red (0-100%)

000-255 Green (0-100%)

000-255 Blue (0-100%)

000-255 White (0-100%)

000-255 Amber (0-100%)

000-255 UV (0-100%)

8 channel mode:

6

7

8

3

4

5

Channel Value

1

Function

000-255 Master Dimmer (0-100%)

2

000-010 No function

011-255 Speed (slow-fast)

000-255 Red (0-100%)

000-255 Green (0-100%)

000-255 Blue (0-100%)

000-255 White (0-100%)

000-255 Amber (0-100%)

000-255 UV (0-100%)

Operating instructions

12 channel mode:

3

141-145

146-150

151-155

156-160

161-165

166-170

171-175

176-180

181-185

186-190

091-095

096-100

101-105

106-110

111-115

116-120

121-125

126-130

131-135

136-140

Channel Value

1 000-255

000-010

2

011-255

000-015

016-020

021-025

026-030

031-035

036-040

041-045

046-050

051-055

056-060

061-065

066-070

071-075

076-080

081-085

086-090

Spring Green

Seafoam Green

Light Blue

Medium Blue

Blue

Deep Blue

Deep Purple

Purple

Dark Violet

Violet

Magenta

Fuchsia Pink

Hot Pink

Crimson

Scarlet Red

Candy Red

White

Pastel Pink

Pastel Baby Pink

Mint Green

Function

Master Dimmer (0-100%)

No function

Strobe (slow-fast)

No function

Red

Flame Red

Deep Orange

Amber

Deep Yellow

Medium Yellow

Yellow

Lime Green

Chartreuse Green

Bright Green

Lawn Green

Green

Neon Green

Slime Green

Harlequin Green

Colour preset www.prolight.co.uk

Spectra Flood 18HEX10 PRO User Manual

8

Operating instructions

12 channel mode (cont):

7

8

9

5

6

10

11

Channel Value

191-195

196-200

3(cont.)

201-205

206-210

211-215

216-255

000-015

016-031

032-047

4

048-063

064-079

080-095

096-111

112-127

128-143

144-159

160-175

176-191

192-207

12

208-223

224-239

240-255

000-255

000-255

000-255

000-255

000-255

000-255

000-255

000-036

037-073

074-110

111-147

148-184

185-221

222-255

Jump 3

Jump 4

Jump 5

Jump 6

Jump 7

Jump 8

Fade 1

Fade 2

Fade 3

Fade 4

Function

Pastel Mint Green

Pastel Blue

Pastel Baby Blue

Ice White

Amber

UV

No function

Jump 1

Jump 2

Fade 5

Fade 6

Fade 7

Speed (slow-fast)

Red (0-100%)

Green (0-100%)

Blue (0-100%)

White (0-100%)

Amber (0-100%)

UV (0-100%)

No function

Dimmer Fast

Dimmer Slow

Linear Curve

Square Curve

Inv. Square curve

S-Type Curve

Colour preset

Programs

Hold value for 2 seconds.

www.prolight.co.uk

Spectra Flood 18HEX10 PRO User Manual

9

Operating instructions

Slave mode:

To set the slave unit, press the “MENU” button on the rear of the unit to show

SLav

on the LED display, press “ SETUP” then us the “ UP” and “ DOWN” buttons to select

yEs

or

NO

. To exit out of any of the above options, press the “MENU” button.

Auto mode:

To access auto mode, press the “ MENU ” button on the rear of the unit to show AU Й O use the “UP” and

“DOWN” buttons to choose yES or NO on the LED display. The unit will now run through its built-in programs. To exit out of any of the above options, press the “ MENU ” button.

Built-in programs:

To select a built-in static colour, press the “ MENU ” button on the rear of the unit until it shows press the “ SETUP ” button to show

Pro

Pr01 then press “ SETUP ” again to show CoOO.

Use the “UP” and

“DOWN” buttons to select the static colour required CoOO ~ Co41.

Press the “ SETUP ” button again to confirm the setting and use the “UP” and “DOWN” buttons to select the flash speed F500 ~ F599 .

To access the built-in programs, press the “ MENU ” button on the rear of the unit until it shows Pro on the LED display. Press “ SETUP ” and use the “UP” and “DOWN” buttons to choose the required program Pr02 ~ Pr16 . Press the “ SETUP ” button to confirm the setting and use the “UP” and

“DOWN” buttons to choose the speed SP01 ~ SPfL . Press the “ SETUP ” button again to confirm the setting and use the “UP” and “DOWN” buttons to select the flash speed F500 ~ F599 . To exit out of any of the above options, press the “ MENU ” button.

Colour mix mode:

To access the colour mix mode press “MENU” until

CoLr

shows on the LED display. Now press the

“SETUP” button and use the “UP” and “DOWN” buttons to select either red (r) green (

9

), blue (

b

), White

( u ) , Amber ( A ) and UV ( l ) . Now use the “UP” and “DOWN” buttons to select the brightness between

r.000

~

r.255

.

Value: 000 - 255 (000 = low brightness, 255 = high brightness)

To exit out of any of the above options, press the “MENU” button.

Dimming Curve Settings

To enter the dimming curve settings, press the “MENU” button on the rear of the unit to show

Set.

Then use the “ UP” and “ DOWN” buttons to select

Cur.

Use the “ UP” and “ DOWN” buttons to select one of four dimming curves.

Cu-1

(linear)

Cu-2

( square law)

Cu-3

(inv square law)

Cu-4

(S-Curve

).

To exit out of any of the above options, press the “MENU” button.

Dimming Speed Settings

To enter the dimming speed settings, press the “MENU” button on the rear of the unit to show

Set.

Then press the “SETUP” button on the rear of the unit to show

Cur.

Then use the “ UP” and “ DOWN” buttons and select

disp.

Press the “ SETUP ” button then use the “ UP” and “ DOWN” buttons to select

Fast

or

sLo.

To exit out of any of the above options, press the “MENU” button.

www.prolight.co.uk

Spectra Flood 18HEX10 PRO User Manual

10

Frequency Settings

To enter the dimming speed settings, press the “MENU” button on the rear of the unit to show

Set.

Then press the “SETUP” button on the rear of the unit to show

freq

, press “ SETUP” again then use the “ UP” and “ DOWN” buttons to select between

f-01, f-03, F-06

and

F-12.

To exit out of any of the above options, press the “MENU” button.

Lock Settings

If a menu selection has not been made for 30 seconds, the screen will lock automatically. Press “MENU” and “SETUP” for 3 seconds to unlock. In the unlocked state, press “MENU” and “SETUP” at the same time to lock quickly. To access the lock setting, press “MENU” button on the rear of the unit to show

SEt.

Press “ SETUP” and use the “ UP” and “ DOWN” buttons to select

LOCј

. Then press “ SETUP” and use the “ UP” and “ DOWN” buttons to select

ON

or

OFF.

To exit out of any of the above options, press the “MENU” button.

Factory reset:

Press the “MENU” button to show

SEt,

Press “ SETUP” and use the “UP” and “DOWN” buttons to find

FACt.

Press “ ENTER” then use the “UP” and “DOWN” buttons to select

yEs

or

NO.

The unit will now have reset to factory settings.

Information:

Press the “MENU” button to show

Info

press “SETUP” and use the “UP” and “DOWN” buttons to find

ver

(software version),

tEnp

(temperature information) and

LIfE

(fixture hours). Press “SETUP” in any of these menus and the relevant information will be displayed. Please see below chart for temperature information codes.

Nor When shown on the unit, temperature detection is normal.

-rt-

-Hi-

When shown on the unit, the unit temperature is too low and will automatically go into protection mode.

When shown on the unit, the unit temperature is too high and will automatically go into protection mode.

www.prolight.co.uk

Spectra Flood 18HEX10 PRO User Manual

11

DMX setup

Setting the DMX address:

The DMX mode enables the use of a universal DMX controller. Each fixture requires a “start address” from 1- 512. A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address. For example, a fixture that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100, would read data from channels: 100,101,102,103,104,105 and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in the chain starts at 107.

DMX 512:

DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions form the controller to the fixture.

DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT”

XLR terminals located on all DMX fixtures (most controllers only have a data “out” terminal).

DMX linking:

DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller, as long as all fixtures and the controller are DMX compliant.

To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the

DMX addressing. For example; a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a

DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.

Also remember that DMX cable must be daisy chained and cannot be split.

DATA cable (DMX cable) requirements (for DMX operation):

This fixture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit.

Further DMX cables can be purchased from all good sound and lighting suppliers or Pro Light Concepts dealers.

Please quote:

LEDJ 1m Interior -

Exterior DMX cable

LEDJ 1m Exterior

DMX cable

LEDJ 2m Exterior

DMX cable

LEDJ 5m Exterior

DMX cable

LEDJ 10m Exterior

DMX cable

Order code: LEDJ91 Order code: LEDJ141 Order code: LEDJ142 Order code: LEDJ143 Order code: LEDJ144

LEDJ 1m Exterior

Power cable

LEDJ 2m Exterior

Power cable

LEDJ 5m Exterior

Power cable

LEDJ 10m Exterior

Power cable

LEDJ Spectra Series

End Cap Set

Order code: LEDJ146 Order code: LEDJ147 Order code: LEDJ148 Order code: LEDJ149 Order code: LEDJ93 www.prolight.co.uk

Spectra Flood 18HEX10 PRO User Manual

12

DMX setup

Notice:

Be sure to follow the diagrams below when making your own cables.

Do not connect the cables shield conductor to the ground lug or allow the shield conductor to come in contact with the XLRs outer casing. Grounding the shield could cause a short circuit and erratic behaviour.

Pin Configuration

3-Pin 5-Pin

Pin 1 - Ground

Pin 2 - Negative

Pin 3 - Positive

Pin 4 - N/C

Pin 5 - N/C

3-Pin XLR female

DMX 512

3-Pin XLR output

1

2

3

GROUND

DMX +

DMX –

DMX 512

3-Pin XLR input

3

1

2

3-Pin XLR male

DMX 512

5-Pin XLR output

DMX 512

5-Pin XLR input

1 2

5 4

3

DMX –

N/C

GROUND

DMX +

N/C

3

2

1

4 5

Line termination:

When longer runs of cable are used, you may need to use a terminator on the last unit to avoid erratic behaviour.

Using a cable terminator will decrease the possibilities of erratic behaviour.

(3-pin - Order ref: CABL90,

5-pin - Order ref: CABL89)

3-Pin

1

3

2

1 ground

3 hot

5-Pin XLR male

2 cold 2 cold

3 hot

1 ground

5-Pin XLR female

1 ground

2 cold

3 hot

5 N/C

4 N/C

5 N/C

4 N/C

3 hot

1 ground

2 cold

Termination reduces signal transmission problems and interference. It is always advisable to connect a DMX terminal, (resistance 120

Ohm 1/4W) between pin 2

(DMX-) and pin 3 (DMX+) of the last fixture.

5-Pin

1

2

3

4

5

5-pin XLR DMX connectors:

Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-pin XLR fixtures may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a

3-pin line a cable adaptor must be used. The diagram below details the correct cable conversion.

5-pin XLR (female)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

Pin 4: N/C

Pin 5: N/C

3-pin XLR (male)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

3-pin XLR (female)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

5-pin XLR (male)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

Pin 4: N/C

Pin 5: N/C www.prolight.co.uk

Spectra Flood 18HEX10 PRO User Manual

13

Multiple fixture power linking

Power linking:

This fixture provides power linking via the power output on the rear allowing multiple units to be connected together. The maximum number of fixtures that can be connected is 20 fixtures @ 240V or 10 fixtures @ 120V (including the first fixture). After the maximum number of fixtures are connected a new power run will need to be started.

Please note: Caution should be used when power linking other fixtures to the Spectra Flood 18HEX10 as the power consumption of other fixtures will vary. Fixtures fitted with lamps often require 2/3 times more current on startup, these may require their own power source.

www.prolight.co.uk

Spectra Flood 18HEX10 PRO User Manual

14

WEEE notice

Correct Disposal of this Product

(Waste Electrical & Electronic Equipment)

(Applicable in the European Union and other European countries with separate collection systems)

This marking shown on the product or its literature, indicates that it should not be disposed of with other household wastes at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.

Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take this item for environmentally safe recycling.

Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes for disposal.

www.prolight.co.uk

Spectra Flood 18HEX10 PRO User Manual

15

www.prolight.co.uk

Spectra Flood 18HEX10 PRO User Manual

16

advertisement

Related manuals

Download PDF

advertisement