CPS Products TRSA30 | R134A and R1234YF Refrigerant Scavenger Machine Owner's Manual
CPS Products TRSA30 | R134A and R1234YF is a refrigerant recovery unit designed to recover contaminated R-134a and R-1234yf from mobile air conditioning systems. It features a 2/3 HP 2-cylinder oil-less compressor, a small high side volume that eliminates the need for a pump down system, and an ignition-proof design for use with Class A2L refrigerants. The unit also includes an integrated tank overfill sensor cord, an easy-to-carry handle, and indicator lights for tank overfill and high-pressure activation.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
TRSA30 Scavenger Refrigerant
Recovery Unit
FOR USE ON CONTAMINATED R-134a AND R-1234yf MOBILE
AIR CONDITIONING SYSTEMS.
CERTIFIED BY INTERTEK (ITS) TO MEET SAE J2851 & UL1963
OPERATION MANUAL
73-256 TRSA30 Manual REV 1.indd 1 2018-08-14 3:39:21 PM
GENERAL INFORMATION
Table of Contents
General Information 2-5
Introduction 2
3 General Safety Instructions
Specifications
Unit Layout
4
5
Operation 6-11
Refrigerant Recovery
Particle Filter Maintenance
6-7
8
Trouble Shooting Chart 9
Warranty 10
Introduction
Congratulations on your purchase of the all new TRSA30 Scavenger Refrigerant Recovery unit. The TRSA30 is especially designed to recover contaminated R-134a or R-1234yf for
Mobile A/C systems. The TRSA30 utilizes 2/3 HP 2 cylinder oil-less compressor.
Features:
• Service hose with Low Side couplers for R-134a and R-1234yf system hook-up
• CPS’s exclusive 1 HP 2-cylinder Oil-less compressor
• Small High Side volume eliminates pump down system
• Ignition proof design for use with Class A2L refrigerants
• Integrated tank overfill sensor cord to connect to float built into the CRX430TS
recover tank.
• Easy to carry handle
• Indicator Lights for Tank Overfill and High Pressure activation.
• High Pressure cutout switch
• Integrated Low Side Pressure Gauge
This manual contains important information on the proper procedures for operating this equipment. Please pay close attention to the: Safety Information, Warnings, and
Cautions provided throughout this manual.
ALWAYS REMEMBER “ SAFETY FIRST ”
2
73-256 TRSA30 Manual REV 1.indd 2 2018-08-14 3:39:21 PM
GENERAL INFORMATION
General Safety Instructions
ONLY QUALIFIED SERVICE PERSONNEL SHOULD OPERATE THIS UNIT. SOME COUN-
TRIES MAY REQUIRE THE USER TO BE LICENSED. PLEASE CHECK WITH YOUR LOCAL
GOVERNMENT AGENCY.
DANGER The recovery tank used with this unit contains liquid refrigerant. Overfilling of the recovery tank may cause a violent explosion resulting in severe injury or even death. weight.
CAUTION -
As a minimum, use a scale to continuously monitor the recovery tank
DANGER Avoid breathing refrigerant vapors and lubricant vapor or mist. Breathing high concentration levels may cause heart arrhythmia, loss of consciousness, or even cause suffocation.
DANGER - ELECTRICAL SHOCK
HAZARD Always disconnect power source when servicing this equipment.
DANGER - EXPLOSION RISK recover flamable refrigerants.
related injuries.
Do not
All hoses may contain liquid refrigerant under pressure. Contact with refrigerant may cause frostbite or other
Wear proper personal protective equipment such as safety goggles and gloves. When disconnecting any hose, please use extreme caution.
CAUTION handle with care when moving and using this refrigerant recovery equipment to avoid damaging the refrigerant tubing and components ,or increasing the risk of a leak.
CAUTION To reduce the risk of fire, avoid the use of extension cords thinner than NO. 14 awg. (2,5mm 2 ) to prevent the overheating of this cord please keep length to a minimum.
CAUTION Do not use this equipment in the vicinity of spilled or open containers of gasoline or other flammable substances.
Make certain that all safety devices are functioning property before operating the equipment.
CAUTION: R-1234yf is a Class A2 flammable refrigerant. Do not recover other flammable besides R-1234yf. Minimize leakage when recovering these refrigerants.
USE IN A WELL VENTILATED AREA.
3
73-256 TRSA30 Manual REV 1.indd 3 2018-08-14 3:39:21 PM
GENERAL INFORMATION
73-256 TRSA30 Manual REV 1.indd 4
4
2018-08-14 3:39:21 PM
GENERAL INFORMATION
Unit Layout
Discharge port
Inlet port with filter
Inlet Pressure
Gauge
Handle
73-256 TRSA30 Manual REV 1.indd 5
5
Tank Overfill
Sensor Cord
Hard Wired
Power Cord
Ignition
Proof Switch
Air Intake
Louver
2018-08-14 3:39:21 PM
OPERATION
REFRIGERANT RECOVERY
IMPORTANT: Before starting the recover of the refrigerant, a refrigerant identifier should be used to determine the type and purity of the refrigerant. Failure to properly identify the refrigerant could potentially expose the user to danger from flammable refrigerants and health hazards from toxic refrigerants. Cross contamination of refrigerants can also occur and would require special handling of the refrigerant.
1. Connect the TRSA30’s discharge (OUT) port to the vapor port of the 30# DOT recover using the provided discharge refrigerant hose.
2. Connect the TRSA30 to the mobile A/C system using the provided low side service hose. Connect the low side service hose to the unit’s inlet (IN) port. Connect either the R134a or R1234yf Low Side Coupler to the end of the service hose. Connect coupler to mobile A/C system low side port.
3. Connect the Yellow Overfill Sensor Cord to the float built into the 30# DOT recovery tank. Plug the unit’s power cord into a suitable 115V power source.
All connections should be done as shown in Diagram-1.
4. Open the vapor valve on the recovery tank.
5. Start unit by pushing main power switch to the “ON” position. Open the Manual Low
Side Coupler.
6. Monitor the A/C system pressure. Once the integrated low side gauge reaches 20”
HG vacuum, turn the unit off. Disconnect the Low Side Coupler from the AC service port.
7. Close the vapor valve on the recovery tank.
8. Disconnect the discharge hose from the TRSA30 discharge port. A small amount of pressurized refrigerant will be released.
6
73-256 TRSA30 Manual REV 1.indd 6 2018-08-14 3:39:21 PM
OPERATION
73-256 TRSA30 Manual REV 1.indd 7
7
2018-08-14 3:39:21 PM
OPERATION
Routine Filter Maintenance
Filter Maintenance: The· unit is equipped with a 100-mesh screen filter. This filter should be checked periodically. A partially clogged filter will slow recovery rate.
Check filter cartridge as follows:
1. Use a 5/8” socket or boxed end wrench to remove IN port as shown in Figure 2.
2. Remove suction port-filter cartridge as shown in Figure 3.
3. Clean cartridge or replace with new cartridge. (CPS #CRXF3)
4. Inspect O-ring. Re-lubricate with compressor oil or equivalent.
5. Place filter cartridge back into suction port fitting.
6. Hand tighten this assembly back onto compressor IN port
7. Use 5/8” socket or boxed end wrench to tighten 1/8 of a turn. Do not over tighten;
O-ring damage may occur.
8. Check connection for leaks.
FILTER DRIER REPLACEMENT IS NOW COMPLETE
Service Parts and Repairs Cautionary Statement
This unit uses ignition proof components thus all service parts for this unit must be
CPS certified and the repair work be done by CPS factory authorized service centers and personnel. This is to minimize the risk of ignition due to incorrect parts or improper service.
8
73-256 TRSA30 Manual REV 1.indd 8 2018-08-14 3:39:22 PM
OPERATION
Trouble Shooting Chart
Problem: The unit will only pull down to 0 pressure or a slight vacuum.
Solution:
Check all LO side connections for possible leaks. If problem persists, check vacuum level directly on the compressor inlet port.
Solution:
Check pressure differential at 400 PSIG discharge pressure. At 400 PSIG, the unit should pull a minimum of a 5” hg. vacuum. If compressor looses its capability of meeting this differential, the compressor seals may need to be replaced.
Problem: HP Red LED lights up, unit starts for a few minutes then shuts off.
Solution:
The high pressure switch has activated. Make sure the discharge valve and recovery tank valve(s) are open. Check for any other restrictions on the discharge port of the unit. Correct restriction. Restart the unit.
Problem: TOS Red LED lights up and the unit shuts off or will not start.
Solution:
1. Check to make sure TOS cord is properly plugged into the recovery tank float.
2. Check tank weight to verify that the tank is full. Empty or replaced tank.
Problem: The unit recovers at a very slow pace.
Solution:
Check for restrictions on the suction side connections. Make sure manifold valves are open. Overtighted hose connections can collapse the rubber gaskets causing a restriction.
73-256 TRSA30 Manual REV 1.indd 9
9
2018-08-14 3:39:22 PM
WARRANTY
CPS ® Products, Inc. guarantees that all products are free of manufacturing and material defects to the original owner for one year from the date of purchase. If the equipment should fail during the guarantee period it will be repaired or replaced (at our option) at no charge. This guarantee does not apply to equipment that has been altered, misused or solely in need of field service maintenance. All repaired equipment will carry an independent
90-day warranty. This repair policy does not include equipment that is determined to be beyond economical repair.
CPS Products, Inc.
CPS Products, Inc. North America
1010 East 31st Street, Hialeah, Florida 33013, USA
Tel: 305-687-4121, 1-800-277-3808, Fax: 305-687-3743
E-mail: [email protected]
Website: www.cpsproducts.com
CPS Canada
1324 Blundell Road, Mississauga, Ontario L4Y 1M5
Tel: 905-615-8620, Fax: 905-615-9745
E-mail: [email protected]
CPS Products N.V
Krijgsbaan 241, 2070 Zwijndrecht, Belgium
Tel: (323) 281 30 40, Fax: (323) 281 65 83
E-mail: [email protected]
CPS Australia PTY. LTD.
109 Welland Avenue, Welland, South Australia 5007
Tel: +61 8 8340 7055, Fax: +61 8 8340 7033
E-mail: [email protected]
73-256 TRSA30 Manual REV 1.indd 10
10
2018-08-14 3:39:22 PM
NOTES