Contents
Achieving the Best Performance
Accessory to Medical Equipment (IEC 60601-1)
Defining the MV-5 5 Channel Multiviewer
6 Connecting the MV-5 5 Channel Multiviewer
Connecting to the MV-5 Using the RS-232 Connection
Connecting to the MV-5 Using the RS-485 Connection
Connecting to the MV-5 Using Ethernet
7 Configuring and Operating the MV-5 Locally
Configuring the MV-5 Using the Menu
Operating the MV-5 Using the Front Panel Buttons
8 Configuring and Operating the MV-5 Remotely
Using the MV-5 Multiviewer Software
11 Default Communication Parameters
Figures
Figure 1: MV-5 5 Channel Multiviewer Front Panel
Figure 2: MV-5 5 Channel Multiviewer Rear Panel
Figure 3: Connecting the MV-5 5 Channel Multiviewer
Figure 4: Local Area Connection Properties Window
Figure 5: Internet Protocol Version 4 Properties Window
Figure 6: Internet Protocol Properties Window
Figure 7: Image Position and Scaling Example
Figure 8: MV-5 Controller Software Main Window
Figure 9: Background Color Window
Figure 10: Image Properties Window
Figure 11: Advanced Properties Window
Figure 12: Device Details Window
Figure 14: Quick Access Toolbar
Figure 15: Quick Access Toolbar Icons
MV-5 - Contents i
Figure 16: Connection Method Window
Figure 20: Switching an Input to a Window
Figure 21: Windows Setup Window
Figure 22: Input Button Properties Window
ii MV-5 - Introduction
1 Introduction
Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been providing a world of unique, creative, and affordable solutions to the vast range of problems that confront video, audio, presentation, and broadcasting professionals on a daily basis. In recent years, we have redesigned and upgraded most of our line, making the best even better!
Our 1,000-plus different models now appear in 11 groups that are clearly defined by function: GROUP 1: Distribution Amplifiers; GROUP 2: Switchers and Routers;
GROUP 3: Control Systems; GROUP 4: Format/Standards Converters; GROUP 5:
Range Extenders and Repeaters; GROUP 6: Specialty AV Products; GROUP 7:
Scan Converters and Scalers; GROUP 8: Cables and Connectors; GROUP 9:
Room Connectivity; GROUP 10: Accessories and Rack Adapters and GROUP 11:
Sierra Video Products.
Congratulations on purchasing your Kramer MV-5 5 Channel Multiviewer which is ideal for:
Professional broadcasting and production studios
Presentation applications
Post production
MV-5 - Introduction 1
2 Getting Started
We recommend that you:
Unpack the equipment carefully and save the original box and packaging materials for possible future shipment
Review the contents of this user manual
i
Go to http://www.kramerelectronics.com/support/product_downloads.asp
to check for up-to-date user manuals, application programs, and to check if firmware upgrades are available (where appropriate).
2.1 Achieving the Best Performance
To achieve the best performance:
Use only good quality connection cables (we recommend Kramer highperformance, high-resolution cables) to avoid interference, deterioration in signal quality due to poor matching, and elevated noise levels (often associated with low quality cables)
Do not secure the cables in tight bundles or roll the slack into tight coils
Avoid interference from neighboring electrical appliances that may adversely influence signal quality
!
Position your MV-5 away from moisture, excessive sunlight and dust
This equipment is to be used only inside a building. It may only be connected to other equipment that is installed inside a building.
2.2 Safety Instructions
!
Caution:
There are no operator serviceable parts inside the unit
Warning:
Use only the power cord that is supplied with the unit
Warning:
Do not open the unit. High voltages can cause electrical shock! Servicing by qualified personnel only
Warning:
Disconnect the power and unplug the unit from the wall before installing
MV-5 - Getting Started 2
2.3 Recycling Kramer Products
The Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC aims to reduce the amount of WEEE sent for disposal to landfill or incineration by requiring it to be collected and recycled. To comply with the WEEE Directive,
Kramer Electronics has made arrangements with the European Advanced
Recycling Network (EARN) and will cover any costs of treatment, recycling and recovery of waste Kramer Electronics branded equipment on arrival at the EARN facility. For details of Kramer’s recycling arrangements in your particular country go to our recycling pages at
http://www.kramerelectronics.com/support/recycling/
.
2.4 Accessory to Medical Equipment (IEC 60601-1)
In the modern medical environment remote access is essential, for example, to transfer clinical data between doctors and to train to medical students. The MV-5 is certified according to the IEC 60601-1-2, Clause 2.1.3, Medical Electrical
Equipment, Part 1: General Requirements for EMC standard which is required when accessory devices are used at locations where medical personnel and patients are present.
The MV-5 constitutes an optional component that can be considered necessary and suitable as part of medical equipment or for use as part of a medical system to provide real time simultaneous video feeds to those present at the local medical environment and at remote locations. In this environment, the MV-5 can be added to the system ONLY if the connecting equipment has been evaluated and meets the IEC 60601-1-2 EMC standards. Note, that when attaching accessory devices to a digital or analog interface, they must comply with the IEC standard for which they are used: EMC Standard (IEC 60601-1-2), Information Technology equipment
(IEC 60950-1 (2ed)).
MV-5 - Getting Started 3
3 Overview
The MV-5 is a versatile, high-performance video and graphic multi-viewer for DVI signals, SD and HD analog signals up to 1920x1200@60Hz, and SDI signals up to
3G HD-SDI. The device can window up to four sources (plus a background) in any layout and output the image as SDI, DVI, component and composite video signals.
Both preprogrammed and customizable screen division is supported.
In particular, the MV-5 has:
16 inputs with rapid selection and switching
An input bandwidth of up to 3Gbps which supports standard definition, high definition and 3G high definition serial digital video signals
SMPTE 259M, 292M and 424M input compliance and support for data rates of 270Mbps, 1.4835Gbps, 1.485Gbps, 2.967Gbps and 2.97Gbps
Input-cable equalization up to 350m (1150ft) for SD signals, 140m (459ft) for
1.5GHz HD signals, and 120m (394ft) for 3GHz HD signals
SD means an NTSC or PAL compatible video format, consisting of 480 (for NTSC) or
576 (for PAL) lines of interlaced video. HD means a video format consisting of 720 active lines of progressive video or 1080 lines of progressive or interlaced video
Any format to any format cross-conversion
Any Standard to any standard cross-conversion
HDCP support on DVI inputs/outputs
Four independent chroma-key engines for each image layer
Window and image scaling, zooming (up to 1000%), and aspect ratio control
Independent layer transparency control
Brightness, contrast, color and sharpness control
Window or input label insertion
Multi-video output formats; SD-SDI (259M), HD-SDI (292M) and 3G HD-SDI
(SMPTE 424M), HDMI, HD, SD, analog and composite
Kramer re-
Klocking™ and equalization on each input—rebuilds the digital signal to travel longer distances
4 MV-5 - Overview
Flexible control options; front panel with menu LCD, Ethernet and RS-232
Screen handling buttons; freeze, size, position
16 user-definable screen layouts
A front panel lock button
The MV-5 is housed in a 19" 2U rack mountable enclosure and is fed from a
100-240 VAC universal switching power supply.
You can control the MV-5 using the front panel buttons, or remotely via:
RS-232/RS-485 serial commands transmitted by a serial controller (see
A PC connected to the Ethernet port on the device via a LAN using the
MV-5 - Overview 5
4 Defining the MV-5 5 Channel Multiviewer
Figure 1 defines the front panel of the MV-5.
3
4
5
#
1
2
6
Figure 1: MV-5 5 Channel Multiviewer Front Panel
Feature
DVI INPUTS 1~4 Buttons
WINDOWS 1~4 Buttons
SDI INPUTS 1~4 Buttons
FREEZE Button
LCD 2 Line x 20 Character
Text Display
SAVE ASPECT Button
Function
Press to select one of the DVI sources
Press to make one of the windows the upper-most window (see Section
windows is not changed
Press to select one of the SDI sources
Press to freeze and release the selected window signal
Displays the current configuration or menu
Press to turn on the Save Aspect mode whereby the window or image aspect is locked during size adjustments (see
#
7
8
9
Feature
LAYERS DEF Button
MENU Button
ENTER Navigation Pad
10 PANEL LOCK Button
11 ANALOG HD INPUTS 1~4
Buttons
12 ANALOG SD INPUTS 1~4
Buttons
13 CROP PVW Button
14
15
WINDOW
Buttons
SIZE Button
POSITION
Button
SIZE Button
ZOOMED
Buttons
POSITION
Button
16 WINDOW SELECT Button
Function
Press to set the order of priority of the window layers
Press to enter the configuration menu. When the menu is displayed, press to exit one level (see
Press Enter to enter the sub-menu or accept a parameter value. Press and hold together with the arrow keys to scroll rapidly through parameter values (see
Press and hold to lock the front panel buttons. Press and hold again to unlock the front panel buttons
Press to select one of the analog HD sources
Press to select one of the analog SD sources
Press to display a full screen preview of the selected window image. Press when zooming to show the mask of the cropped image
Press to adjust the size of the selected window (see Section
Press to adjust the position of the selected window
Press to adjust the image size within the selected window, that is, the degree of zoom
Press to adjust the image position within the selected window, that is, the image panorama
Press to step through the windows to select an active window to adjust
Figure 2 defines the rear panel of the MV-5.
Figure 2: MV-5 5 Channel Multiviewer Rear Panel
#
1
2
3
4
Feature
RGB BNC Connectors
IN 1
IN 2
IN 3
IN 4
5
6
7
8
9
ANALOG SD INPUTS BNC Connectors
RGB/COMP OUT BNC Connectors
RS-232 9-pin D-sub Serial Connector
PROGRAM Button
RS-485 3-pin Terminal Block
10 FACTORY RESET Button
11 ETHERNET RJ-45 Connector
Function
Connect to an analog HD video source
Connect to an analog HD video source
Connect to an analog HD video source
Connect to an analog HD video source
Connect to up to 12 composite, 6 YC or 3 YUV sources
Connect to an analog HD or SD acceptor
Connect to a PC/serial controller (see Section
For the use of Kramer service personnel only
Connect to an RS-485 serial controller (see Section
Press while power cycling the device to reset to factory default values (see Section
Connect to a PC via a LAN (see Section
# Feature
12 DVI IN 1 ~ 4 DVI Connectors
Function
Connect to the DVI video sources (1 to 4)
13 SDI IN 1 ~ 4 BNC Connectors
14
16
SDI OUT 1 and 2 BNC Connectors
15 BACKGROUND DVI IN Connector
DVI OUT DVI Connector
Connect to the SDI video sources (1 to 4)
Connect to the SDI video acceptors (1 and 2)
Connect to the DVI background video source (see
Connect to the DVI acceptor
17 Mains Power Connector, Fuse and Switch Plug in the power cord, switch the device on and off
5 Installing in a Rack
This section provides instructions for rack mounting the unit.
10 MV-5 - Installing in a Rack
6 Connecting the MV-5 5 Channel Multiviewer
You can use your MV-5 to switch four of the 16 inputs (four HD, four SD, four DVI, and four SDI), to four outputs (two SDI, a DVI and an HD). The four inputs are combined in a customizable format and then combined with a user-selectable background.
i
Always switch off the power to all devices before connecting them to your MV-5. After connecting your MV-5, connect its power and then switch on the power to each device.
MV-5 - Connecting the MV-5 5 Channel Multiviewer 11
12
Figure 3: Connecting the MV-5 5 Channel Multiviewer
To connect the MV-5 5 Channel Multiviewer as illustrated in the example in
1. Connect up to four HD video sources, (for example, component video players) to the RGB IN BNC connectors.
MV-5 - Connecting the MV-5 5 Channel Multiviewer
2. Connect up to 12 composite, six YC or three YUV SD video sources, (for example, component and CV composite video players) to the Analog SD
INPUTS BNC connectors.
3. Connect the RGB/Comp OUT BNC connectors to an analog HD or SD video acceptor, (for example, an RGB/YUV video recorder).
4. Connect up to four DVI sources, (for example, computer graphics sources) to the DVI In connectors.
5. Connect up to four SDI sources, (for example, a 3G HD-SDI camera and an
SDI player) to the SDI In BNC connectors.
6. Connect the SDI Out BNC connectors to up to two SDI acceptors (for example, an HD-SDI non-linear editor).
7. Connect a DVI source, (for example, a computer graphics source) to the
Background DVI In connector.
8. Connect the DVI Out connector to a DVI acceptor, (for example, a display).
9. If required, connect a controller to the:
Ethernet connector (see Section
10. Connect the power cord and power the device on.
MV-5 - Connecting the MV-5 5 Channel Multiviewer 13
6.1 Connecting to the MV-5 Using the RS-232 Connection
You can connect to the MV-5 via an RS-232 connection using, for example, a PC.
Note that a null-modem adapter/connection is not required.
To connect to the MV-5 via RS-232:
Connect the RS-232 9-pin D-sub rear panel port on the MV-5 unit via a
9-wire straight cable (only pin 2 to pin 2, pin 3 to pin 3, and pin 5 to pin 5 need to be connected) to the RS-232 9-pin D-sub port on your PC
6.2 Connecting to the MV-5 Using the RS-485 Connection
6.2.1 Connecting via RS-485
You can operate the MV-5 via the RS-485 port from a distance of up to 1200m
(3900ft) using any device equipped with an RS-485 port (for example, a PC).
To connect a device with an RS-485 port to the MV-5:
Connect the A (+) pin on the RS-485 port of the PC to the A (+) pin on the
RS-485 port on the rear panel of the MV-5
Connect the B (
–) pin on the RS-485 port of the PC to the B (–) pin on the
RS-485 port on the rear panel of the MV-5
Connect the G pin on the RS-485 port of the PC to the G pin on the RS-485 port on the rear panel of the MV-5
If you are using shielded cable, connect the shield only to the G pin of device 1
6.3 Connecting to the MV-5 Using Ethernet
You can connect to the MV-5 via Ethernet using either of the following methods:
Directly to the PC using a crossover cable (see
Via a network hub, switch, or router, using a straight-through cable (see
14 MV-5 - Connecting the MV-5 5 Channel Multiviewer
6.3.1 Connecting the Ethernet Port Directly to a PC
You can connect the Ethernet port of the MV-5 directly to the Ethernet port on your
PC using a crossover cable with RJ-45 connectors.
i
This type of connection is recommended for identifying the MV-5 with the factory configured default IP address.
After connecting the MV-5 to the Ethernet port, configure your PC as follows:
1. Click Start > Control Panel > Network and Sharing Center.
2. Click Change Adapter Settings.
3. Highlight the network adapter you want to use to connect to the device and click Change settings of this connection.
The Local Area Connection Properties window for the selected network
adapter appears as shown in Figure 4 .
Figure 4: Local Area Connection Properties Window
MV-5 - Connecting the MV-5 5 Channel Multiviewer 15
4. Click on Internet Protocol Version 4 (TCP/IPv4) to highlight the selection.
5. Click Properties.
The Internet Protocol Properties window relevant to your IT system appears
16
Figure 5: Internet Protocol Version 4 Properties Window
6. Select Use the following IP Address for static IP addressing and fill in the
details as shown in Figure 6 .
You can use any IP address in the range 192.168.1.1 to 192.168.1.255
(excluding 192.168.1.39) that is provided by your IT department.
MV-5 - Connecting the MV-5 5 Channel Multiviewer
Figure 6: Internet Protocol Properties Window
7. Click OK.
8. Click Close.
6.3.2 Connecting the Ethernet Port via a Network Hub or Switch
You can connect the Ethernet port of the MV-5 to the Ethernet port on a network hub or using a straight-through cable with RJ-45 connectors.
MV-5 - Connecting the MV-5 5 Channel Multiviewer 17
7 Configuring and Operating the MV-5 Locally
This section describes:
Configuring the MV-5 using the Menu (see
Operating the MV-5 using the front panel buttons (see
When the MV-5 is powered on, the device performs a self test. If the test is successful, the Window/Input list is displayed, an example of which is shown below.
WIN1 WIN2 WIN3 WIN4
DVI1 SDI2 AnH3 SDI3
This initial state is the Main mode which is the default Window input configuration.
You can control and adjust window and image geometry using the front panel buttons from the Main mode without entering the Menu. In the Main mode, pressing one of the four Windows buttons (the selected button lights yellow) gives this window the highest priority (1) and places this window of top of the other windows. All other widows retain their layer order but the priority of each drops by one.
In the Main mode, using the Inputs buttons, you can switch the input or freeze layer 1, not the other layers. Pressing the priority 1 layer Window button causes the layer to become invisible (subsequent layers all increase their priorities by 1) and the Window button no longer lights.
In the Main mode, layer priority is set by the order in which the Windows buttons are pressed.
In order to manage other layers without changing all layer priorities, you need to invoke the Adjustment mode.
18 MV-5 - Configuring and Operating the MV-5 Locally
Pressing any of the following buttons puts the device into the Adjustment mode:
Layers Def
Window Select
Window Size or Position
Zoomed Size or Position
Menu
The device remains in Adjustment mode as long as one of these buttons is lit red.
Note: In the Adjustment mode, pressing Windows buttons does not affect layer priorities, but only selects a window to adjust, that is, it makes this window active.
(If the selected window was initially invisible it remains invisible while it is being adjusted.)
It is possible to modify multiple parameters immediately following one another. For example, if the Window size is modified, you can press another button immediately in order to modify the Window position. It is also possible to modify the same parameter for another Window without returning to Main mode.
To return to the Main mode (that is, the default window input configuration), press any of the buttons listed above that light red. Following this, initial window priorities are restored and the initial Window button will again light only if the Window priorities were not specifically changed while in the Layer Def mode.
Using the Layer Def button, you can then set the priority of any layer (0 to make it invisible.
MV-5 - Configuring and Operating the MV-5 Locally 19
7.1 Configuring the MV-5 Using the Menu
The menu is displayed on the character display when the Menu button is pressed.
Navigation through the menu is performed as follows:
Menu
—Enter the Menu or move up one level in the menu hierarchy
Enter
—Enter the selected parameter or accept the displayed parameter/value
Up (▲)—scroll up through the Menu/parameter/value list
Down (▼)—scroll down through the Menu/parameter/value list
Left (◄)—decrement the current value or move left through the options list
Right (►)—increment the current value or move right through the options list
The main menu comprises the following sections:
Load Setup Sub-menu (see Section
Save Current Setup Sub-menu (see Section
Input Configuration Sub-menu (see Section
Output Configuration Sub-menu (see Section
Window Configuration Sub-menu (see Section
Input Signal Status Sub-menu (see Section
System Parameters Sub-menu (see Section
7.1.1 Load Setup Sub-menu
The Load Setup sub-menu allows you to load one of the 16 preset configurations.
To load a setup:
1. Press Menu.
The Menu button lights and the current setup is displayed.
2.
Use the up (▲) and down button (▼) to navigate to the Load Setup submenu.
20 MV-5 - Configuring and Operating the MV-5 Locally
3.
Use the left (◄) and right (►) buttons to select the required preset to load.
4. Press Enter.
The selected preset is loaded and the display changes to indicate the current setup.
5. Press Menu to exit the setup.
The display changes to show the default Window-Input configuration.
7.1.2 Save Current Setup Sub-menu
The Save Current Setup sub-menu allows you to save the current setup to one of the 16 presets.
To save the current configuration to a preset:
1. Press Menu.
The last used sub-menu is displayed.
2.
Use the up (▲) and down button (▼) to navigate to the Save Current Setup sub-menu.
3.
Use the left (◄) and right (►) buttons to select the required preset to which you want to save the current setup.
4. Press Enter.
The current setup is saved and the display changes to indicate the current setup.
5. Press Menu to exit the setup.
The display changes to show the default Window-Input configuration.
7.1.3 Input Configuration Sub-menu
The Input Configuration sub-menu allows you to assign SD input buttons to specified connectors, set analog HD input formats, and set the analog HD pixel phase.
MV-5 - Configuring and Operating the MV-5 Locally 21
22
Parameter
Assign Analog SD
Button 1 (or 2, 3 or
4) to:
Description
Assigns one of the four analog SD input buttons to the selected input format
Analog HD INP1
(or 2, 3 or 4)
Format:
Analog HD INP 1
(or 2, 3 or 4) Pixel
Phase:
Analog HD INP 1
(or 2, 3 or 4) Horiz
Start:
Analog HD INP 1
(or 2, 3 or 4)
Vertical Start:
Assigns one of the four analog HD input buttons to the selected input format
Assigns the position for sampling analog HD input signal
Adjusts the horizontal start for an HD or graphic input signal
Adjusts the vertical start for an HD or graphic input signal
DVI INP 1 (or 2, 3,
4 or BackGround)
HDCP capability)
Assigns HDCP capability for each DVI input individually
Values
CV1, CV2, CV3, CV4, CV5, CV6, CV7,
CV8, CV9, CV10, CV11, CV12, YC1,
YC2, YC3, YC4, YC5, YC6, YUV1,
YUV2, YUV3
Default
—CV1
RGBHV, RGBS, RGsB, YUV BiSync,
YUV TriSync
Default
—RGBHV
0 to 31
Default
—0
-100 to 100
Default
—0
-50 to 50
Default
—0
YES, NO
Default
—YES
To set an analog HD input to an input format (for example, Input 2 to format
RGBS):
1. Press Menu.
The last used sub-menu is displayed.
2.
Use the up (▲) and down button (▼) to navigate to the Input Configuration sub-menu.
3. Press Enter.
The Assign Analog SD Button 1 format is displayed.
4.
Use the up (▲) and down button (▼) to navigate to the HD Input 2 Format selection.
5.
Use the left (◄) and right (►) buttons to select the RGBS format.
6. Press Menu.
The current setup is saved and the display changes to the Input
Configuration sub-menu.
7. Press Menu again to exit the setup.
The display changes to show the default Window-Input configuration.
MV-5 - Configuring and Operating the MV-5 Locally
7.1.4 Output Configuration Sub-menu
The Output Configuration sub-menu allows you to set the output video characteristics, such as, output standard, background mode and HDCP support.
Parameter Description Values
Outp. Standard:
OutpStand Mode:
Analog output
Format:
Sets the signal output format
Sets the output standard mode
Sets the analog output format
480i/60, 576i/50, 720p/50, 720p/59, 720p/60,
1080i/50, 1080i/59, 1080i/60, 1080p/23,
1080p/24, 1080p/25, 1080p/29, 1080p/30,
1080p/50, 1080p/59, 1080p/60, 1080psf/23,
1080psf/24, 1080psf/25, 1080psf/29,
1080psf/30, 640x480/60, 640x480/72,
640x480/75, 640x480/85, 800x600/60,
800x600/72, 800x600/75, 800x600/85,
1024x768/60, 1024x768/70, 1024x768/75,
1024x768/85, 1152x864/75,
1280x768/60rducBL, 1280x768/60,
1280x768/75, 1280x768/85, 1280x960/60,
1280x768/85, 1280x1024/60, 1280x1024/75,
1360x768/60, 1366x768/60,
1400x1050/60rducBL, 1400x1050/60,
1400x1050/75, 1440x900/60rducBL,
1440x900/60, 1440x900/75, 1440x900/85,
1600x1200/60, 1680x1050/60rducBL,
1680x1050/60, 1920x1200/60rducBL
Default
—480i/60
Forced Standard, Auto byDVI BackGrnd
Default
—Forced Standard
RGBHV, RGBS, RGsB, YUV BiSync, YUV
TriSync
Default
—RGBHV
Analog SDTV
Format:
BackGround Color
B-value:
Sets the analog SDT format
BackGround Mode: Sets the background
BackGround Color
R-value:
BackGround Color
G-value: mode
Sets the background red color value
Sets the background green color value
RGBHV or YUV, 3 CVBS, YC and CVBS, , YUV
TriSync
Default
—RGBHV
Colored Background, DVI Input BackGrnd
Default
—Colored Background
0 to 255
Default
—0
0 to 255
Default
—0
Sets the background blue color value
0 to 255
Default
—0
No Signal Handle
Mode:
RGB Analog
Output Sync Mode
RGB Analog
Output H Sync
Position
Sets the operation when no input signal is present
Black Screen, Blue Screen, Remove Window,
Freeze Last Picture
Default
—Black Screen
Sets Analog Output Sync
Mode
Sets Analog Output H
Sync Position (in pixels)
CEA Standard, Inverse 1, Inverse 2
Default
—CEA Standard
–75 to 75
Default
—0
MV-5 - Configuring and Operating the MV-5 Locally 23
Parameter
RGB Analog
Output V Sync
Position
DVI Output HDCP mode
Description
Sets Analog Output V
Sync Position (in lines)
Assigns DVI Output
HDCP mode
Values
–1 to 7
Default
—0
Follow Output, Follow Input, HDCP on Output:
“ON”, HDCP on Output: “OFF”
Default
—Follow Input
HDCP is the High-bandwidth Digital Content Protection system which is designed for protecting AV content from being copied. The DVI inputs (four for windows and one for the background) can accept HDCP protected signals. In order to meet all
HDCP requirements and to support the multi-window features of the MV-5, there are various methods for handling different cases involving of input and output
HDCP encrypted signals.
24
Using the Output Configuration Sub-menu, it is possible to select the following
HDCP output modes:
1. Follow Input. If at least for one active window which carries an HDCP protected DVI input signal is selected, then on the DVI output HDCP encryption is turned on and simultaneously all others outputs (SDI and
Analog) are forced to mute in order to meet HDCP license requirements. If a window with a DVI input with HDCP protection is selected, then in the case of the Main Mode of the MV-5, (that is, when the LCD shows WIN1, WIN2,
WIN3, WIN4), then a small label appears to the left of WINx showing two vertically placed symbols c and p, (content protection). In order to indicate the same HDCP status for the background DVI input, a different label is used which looks like a triangle at the bottom left hand side of the LCD.
If the DVI output of the MV-5 is connected to a video acceptor that does not support HDCP, then all output formats that do not carry the HDCP protected input signal are available, but not those outputs which do carry the HDCP protected signal (for example, DVI, SDI and Analog). This output window is either black or entirely removed from the output image depending on the setting of the parameter NO SIGNAL HANDLE MODE in the Output
Configuration Sub-menu.
The Follow Input setting signifies that the output HDCP encryption is turned on (SDI and Analog are muted in this case) or off depending on the
MV-5 - Configuring and Operating the MV-5 Locally
presence or absence of HDCP on all active DVI inputs, and if the sink does not support HDCP, then this window is muted (removed) from the output image.
2. Follow Output. If the video acceptor (for example, a monitor) is HDCP capable, then independently of the presence or absence of an HDCP protected input signal, HDCP encryption on the DVI output is turned on (but in this case, the SDI and analog outputs are available only if HDCP is absent on all DVI inputs).
If the video acceptor does not support HDCP, the HDCP encryption on the
DVI output is turned off and simultaneously all DVI inputs become HDCP non-capable. In this case, the responsibility for content protection remains completely on the source, as it sees its video acceptor (that is, the MV-5 DVI input) as not being HDCP capable. All other outputs (SDI and analog) are available.
3. HDCP on output: ON. The HDCP encryption on the DVI output is turned on, independently of the presence or absence of HDCP protected input signals.
This mode can be used to protect content created on the MV-5 from being copied on the DVI output.
4. HDCP on output: OFF. The HDCP encryption on the DVI output is turned off and simultaneously all five DVI inputs become HDCP non-capable. In this case, the responsibility for content protection remains completely on the source, as it sees its video acceptor (that is, the MV-5 DVI input) as not being HDCP capable. All other outputs (SDI and analog) are available.
To select the RGsB format for Analog HD output:
1. Press Menu.
The last used sub-menu is displayed.
2.
Use the up (▲) and down button (▼) to navigate to the Output Configuration sub-menu.
3. Press Enter.
The Output Standard: message is displayed.
MV-5 - Configuring and Operating the MV-5 Locally 25
26
4. Use the up (▲) and down button (▼) to navigate to the Analog HD output
FORMAT: option.
5.
Use the left (◄) and right (►) buttons to select the RGsB option.
6. Press Enter.
The current setup is saved.
7. Press Menu.
The display changes to the Output Configuration sub-menu.
8. Press Menu again to exit the menu.
The display changes to show the default Window-Input configuration.
To select the DVI input as the background signal:
1. Press Menu.
The last used sub-menu is displayed.
2.
Use the up (▲) and down button (▼) to navigate to the Output Configuration sub-menu.
3. Press Enter.
The Output Standard: message is displayed.
4.
Use the up (▲) and down button (▼) to navigate to the BackGrnd MODE: option.
5. Use the left (◄) and right (►) buttons to select the DVI INPUT
BACKGROUND option.
6. Press Enter.
The current setup is saved.
7. Press Menu to exit the sub-menu.
The display changes to the Output Configuration sub-menu.
8. Press Menu again to exit the menu.
The display changes to show the default Window-Input configuration.
MV-5 - Configuring and Operating the MV-5 Locally
7.1.5 Window Configuration Sub-menu
The Window Configuration sub-menu allows you to set the window characteristics, such as, contrast and image transparency.
Parameter
Brightness:
Contrast:
Color:
Description
Sets the brightness of the window
Sets the contrast of the window
Sets the color of the window
Values
-50% to 50% in 1% increments
Default
—0
50% to 150%
Default
—100
50% to 150%
Default
—100
Sharpness:
Border Color
R-Value:
Sets the contrast of the window 0% to 150% in 10% increments
Default
—0
Border Thickness: Sets the border width of the window 0 to 20
Default
—0
Sets the red value of the window 0 to 255
Default
—0
Border Color
G-Value:
Border Color
B-Value:
Sets the green value of the window
Sets the blue value of the window
0 to 255
Default
—0
0 to 255
Default
—0
Keyer:
Keyer Y Threshold
Min:
Controls the Keyer engine in the selected window
Sets the minimum threshold for the Y value
Disabled, Enabled
Default
—Disabled
0 to 255
Default
—0
Keyer Y Threshold
Max:
Keyer U Threshold
Min:
Keyer U Threshold
Max:
Keyer V Threshold
Min:
Keyer V Threshold
Max:
Image
Transparency:
Test
Label Mode:
Label Position:
Sets the maximum threshold for the
Y value
Sets the minimum threshold for the
U value
Sets the test signal for the selected window
0 to 255
Default
—0
0 to 255
Default
—0
Sets the maximum threshold for the
U value
Sets the minimum threshold for the V value
Sets the maximum threshold for the
V value
0 to 255
Default
—0
0 to 255
Default
—0
0 to 255
Default
—0
Sets the image transparency for the selected Window
0 to 255
Default
—0
No Test Signal, Color Bars
100%, Split Bars 100%, Ramp
100%
Sets the label mode for the selected window
Sets the label position for the selected window
No Window Label, Black WND
Label, White WND Label, Black
Inp Label, White Inp Label,
Default
—No Window Label
Bottom Left, Bott Center, Bott
Right, Top Left, Top Center,
Top Right
Default
—Bottom Left
MV-5 - Configuring and Operating the MV-5 Locally 27
28
The keyer engine allows you to overlay one image on top of another. A keyed image is one image that is superimposed over another, such that portions of the top image are made transparent (keyed out) so that the background image can show through. The keyer settings allow you to vary the color(s) that are keyed out.
Window labeling allows you to turn on or off an identifying label that appears in the border of a window. For a label to be displayed, the border must be turned on and also must be of a contrasting color to the label text.
To set the Window Border Color Red value:
1. Press Menu.
The last used sub-menu is displayed.
2.
Use the up (▲) and down button (▼) to navigate to the Window
Configuration sub-menu.
3. Press Enter.
The Window Configuration Contrast option is displayed.
4. Using the Windows buttons, select the window to be modified.
The selected window is displayed.
5. Use the up (
▲) and down button (▼) to navigate to the Color R-Value option.
6.
Use the left (◄) and right (►) buttons to select the red value.
7. Press Enter.
The current setup is saved.
8. Press Menu to exit the sub-menu.
The display changes to show the Window Configuration sub-menu.
9. Press Menu again to exit the menu.
The display changes to show the default Window-Input configuration.
Note: Setting the Window border color green and blue values is performed in the same manner.
MV-5 - Configuring and Operating the MV-5 Locally
7.1.6 Input Signal Status Sub-menu
The Input Status sub-menu displays the input states and is read-only.
Parameter
Window 1 (or 2, 3 or 4) Input:
Signal:
DVI Background Input:
Signal:
Description
Displays the input currently selected for each window and the signal detected
Displays the signal currently detected on the DVI
Background input
7.1.7 System Parameters Sub-menu
The System Parameters sub-menu allows you to view the current firmware version, serial number, serial port parameters, and to view and edit the Ethernet port parameters.
Version
Parameter
MV-5 HW Revision FW
MV-5 Serial Number
Serial Port Baud Rate
Ethernet IP address
Ethernet Subnet Mask
Ethernet IP Gateway
Description
Hardware revision firmware number and version
MV-5 device TCP/IP address
MV-5 device network mask
MV-5 network gateway
DHCP Enable
Machine Identification
Number
Enables and disables automatic IP addressing
Ethernet UDP Port Number Sets the TCP UDP port number.
One item for three lowest significant digits; second item for 2 highest significant digits
Ethernet TCP Port Number Sets the TCP port number.
One item for three lowest significant digits; second item for 2 highest significant digits
LCD Sleep Mode
Brightness:
Sets the LCD display sleep mode brightness
LCD Operating Brightness: Sets the LCD display brightness
Sets the device ID that determines the position of the MV-5 on the RS-485 bus
Default: 5000
0% to 100%
Default
—100
0% to 100%
Default
—100
1 to 15
Default
—1
Values
X
X.X..XXXX
XXXXXXXXX
115200
Default
192.168.1.39
Any valid address
Default
255.255.0.0
Any valid mask
Default
0.0.0.0
Any valid gateway address
OFF, ON
Default: OFF
Default: 50000
MV-5 - Configuring and Operating the MV-5 Locally 29
7.2 Operating the MV-5 Using the Front Panel Buttons
This section describes:
Assigning inputs to windows (see
Setting window layer priority (see
Changing the size and aspect ratio of a window (see
Adjusting the position of a window (see
Adjusting the image zooming degree inside a window (see
Adjusting the image panorama inside a window (see
Freezing and releasing the output (see
Locking and unlocking the front panel buttons (see
Resetting the device to factory defaults (see
7.2.1 Assigning Inputs to Windows
To assign an input to the top-layer window when its button is lit, (for
example, DVI Input 3 to Window 2):
Press DVI Inputs button 3.
The DVI Inputs button 3 lights and DVI Input 3 is assigned to Window 2
To assign an input to a non top-layer window when its button is not lit, (for
example, SDI Input 1 to Window 4) without affecting the layer priorities:
1. Press Windows Select button.
The Windows Select button lights red.
2. Press Windows button 4.
The Windows button 4 lights.
3. Press SDI Inputs button 1.
The SDI Inputs button 1 lights and SDI Input 1 is assigned to Window 4.
4. Press the Windows Select button.
The Windows Select button no longer lights.
30 MV-5 - Configuring and Operating the MV-5 Locally
7.2.2 Setting Window Layer Priority
Each window can be assigned a layer priority.
To assign a window a layer priority (for example, Window 3 to priority 1):
1. Press the Layers Def button.
The Layers Def button lights and a window and its current priority are displayed.
2. Press the Windows button 3.
The Windows button 3 lights.
3.
Use the left (◄) and right (►) arrow buttons to cycle through to priority 1.
4. Press the Layers Def button to save the changes.
The button no longer lights, Window 3 is set to priority 1 and the display returns to the Window/Input selection.
7.2.3 Changing the Size and Aspect Ratio of a Window
You can change the size and aspect ratio of each window independently. Window size can be adjusted from 10% to 100% (full screen) of the screen size.
There are two ways to change the windows size:
Adjusting the horizontal and vertical window size separately (thereby possibly altering the window aspect ratio).
Locking the aspect ratio and adjusting the horizontal and vertical sizes together.
When the window aspect ratio is locked, (for example, at 100%), then any change to the window size leaves the output screen aspect ratio the same. This can be used in a situation where for example, the output monitor connected to the MV-5 has a screen aspect ratio of 16:9, (that is, 1.77) and the window aspect ratio is set to 75%. The resulting aspect ratio of this window will be 1.77 x 0.75 = 1.33 (that is,
4:3). If there is a need to correctly represent a 4:3 format, (for example, PAL) on a
16:9 screen, the window aspect ratio must be set to about 75%, and visa versa; to
MV-5 - Configuring and Operating the MV-5 Locally 31
represent HD video format (16:9) on an SDTV monitor (4:3), set the aspect ratio to about 133%.
The broad range of aspect ratio adjustment on the MV-5 allows for a wide range of different PC graphic input and output resolutions.
In addition to adjusting the size of the window, it is also possible to adjust the size of the image within the window. If a window image is not zoomed and Save Image
Aspect Ratio is not active (see
), then changing the window size or
aspect ratio results in the window image changing its size and aspect ratio to match the window changes.
If it is necessary to retain the window image size and aspect ratio independent of any change in size or aspect ratio of the window, then turn on Save Image Aspect
Ratio.
The example shown in Figure 7 illustrates image position and scaling.
32
Figure 7: Image Position and Scaling Example
“In” has been set to 300,150 as its top-left source coordinate, with a size of 750,400.
“Out” has been set to 50,50 (that is, close to the top left) with a size of 250,300. The MV-5 ensures that the whole of the source (of size 750 by 400) is scaled to the required output (of size 250 x 300).
To adjust the horizontal and vertical size of a window separately:
1. Press the Window Size button.
The Window Size button lights.
2. If the Save Aspect button is lit, press the button to turn it off.
MV-5 - Configuring and Operating the MV-5 Locally
3. Press the required Window button.
The selected Window button lights.
4.
Use the left (◄) and right (►) buttons to adjust the window width, and use the up (▲) and down button (▼) to adjust the window height.
The size changes in real-time.
5. Press the Window Size button.
The button no longer lights.
To change the size of a window and aspect ratio of a window, (for example,
Window 2, size 90% and aspect ratio 80%):
1. Press the Window Size button.
The Window Size button lights.
2. Press the Save Aspect button.
The Save Aspect button lights.
3. Press the Windows button 2.
The Windows button 2 lights.
4.
Use the left (◄) and right (►) arrow buttons to decrease or increase respectively the horizontal size until 90% is displayed.
5.
Use the up (▲) and down (▼) arrow buttons to increase or decrease respectively the vertical size until 80% is displayed.
6. Press the Window Size button to save the changes.
The button no longer lights, the window size is set and the display returns to the Window/Input selection.
7.2.4 Adjusting the Position of a Window
The horizontal and vertical position of each window can be modified.
To adjust the position of a window:
1. Press the Window Position button.
The Window Position button lights.
MV-5 - Configuring and Operating the MV-5 Locally 33
2. Select the required window by pressing one of the Windows buttons.
The selected Windows button lights.
3. Use the left (◄) and right (►) arrow buttons to move the window horizontally, and the up (▲) and down (▼) arrow buttons to move the window vertically.
The display changes in real-time.
4. Press the Window Position button.
The button no longer lights.
7.2.5 Zooming into an Image in a Window
If an input image contains an area that is essential and must be displayed in the output window while the rest of the image can be discarded, you can use Image
Zooming to accomplish this. Image Zooming provides adjustment of image size relative to the Window size.
You can change the Image size and aspect ratio independently inside each window relative to the window size and aspect ratio. The image size (that is, the zooming) is adjustable between 100% (the Image just fits the Window) to 1000%
(10 times the original Image size). If the window size or aspect ratio changes then the Image size changes in such a manner that the Image remains the same inside within the window.
There are two ways to change the Image size and aspect ratio (Zoom):
The horizontal and vertical Image sizes (Zoom) can be adjusted separately.
In this mode, the Image aspect ratio conforms to the Window; changes to the
Window cause the same changes to the Image.
Locking the Image aspect ratio while zooming the Image. To engage this mode turn on Save Image Aspect Ratio by pressing the Zoomed Size button and then pressing the Save Aspect button (the button lights red). It is then possible to adjust the Image Size (simultaneously the horizontal and vertical zoom) using only one parameter (Image Size) and the aspect ratio remains constant but can be adjusted independently. If the Aspect Ratio (by default) is set to 100% and changes are made to the Image Size, the Image aspect ratio follows that of the input-signal aspect ratio.
34 MV-5 - Configuring and Operating the MV-5 Locally
Note: When using the locked Image aspect ratio mode, changing the Window aspect ratio can cause essential parts of the Image to be cropped.
You can use the Crop PVW button to provide easier and more precise zooming adjustment. If this button is pressed in Main mode (the button lights red), the toplayer window is adjusted to conform to the exact size of the output screen.
Pressing any of the Window or Zoomed buttons causes the border mask of the cropped image to appear on the fitted image. It is then possible to adjust the
Window or Zoomed Size and Position to see which part of the image will be visible in the window and which part will be discarded.
This function can be used only for the top-layer window. To adjust other windows in the Main mode, you must first select the required Window using the Windows buttons, that is, to move the required layer to the top.
In the event that something important suddenly appears in the image, the Crop
PVW button can be used not only to see the cropping mask, but also to quickly revert to a full-screen in the window. The Crop PVW button must be pressed while the device is in Main mode. Pressing this button again returns the MV-5 to the initial windows Sizes and Positions.
To adjust the horizontal and vertical Image size (Zoom) within a Window:
1. Press the Zoomed Size button.
The Zoomed Size button lights.
2. If the Save Aspect button is lit, press it to turn it off.
3. Select the required Window by pressing the relevant Window button.
The selected Window button lights.
4.
Use the left (◄) and right (►) buttons to adjust the Image width, and the up
(▲) and down buttons (▼) to adjust the Image height relative to the Window width and height respectively. If required, press the Crop PVW button to check the image cropping using the mask border.
The size changes in real-time.
MV-5 - Configuring and Operating the MV-5 Locally 35
5. Press the lit Zoomed Size button.
The button no longer lights.
To change the size and aspect ratio of the Image inside a window, (for
example, Window 2, Image size 200% and aspect ratio 120%):
1. Press the Zoomed Size button.
The Zoomed Size button lights.
2. Press the Save Aspect button.
The Save Aspect button lights.
3. Press Windows button 2.
The selected Windows button lights.
4.
Use the left (◄) and right (►) arrow buttons to decrease or increase respectively the size until 200% is displayed.
5. Use the up (▲) and down (▼) arrow buttons to increase or decrease respectively the aspect ratio until 120% is displayed. If required, press the
Crop PVW button to check the image cropping using the mask border.
6. Press the Zoomed Size button to save the changes.
The button no longer lights, the Image size and aspect ratio are set and the display returns to the Window/Input selection.
7.2.6 Adjusting the Position of the Image Inside a Window
– Panning
If an Image has been zoomed, (that is, horizontal or vertical values of the Image size are greater than 100%), then cropping takes place. You can pan the Image inside the Window in order to reveal the essential portion of the Image.
To adjust the position of the image inside a window (panning):
1. Press the Zoomed Position button.
The Zoomed Position button lights.
2. Press the required Window button to select it.
The Window button lights and the window is selected.
36 MV-5 - Configuring and Operating the MV-5 Locally
3.
Use the left (◄) and right (►) buttons to move the Image horizontally, and use the up (▲) and down button (▼) to move the Image vertically. If required, press the Crop PVW button to check the image cropping using the mask border.
The position changes in real-time.
4. Press the Zoomed Position button.
The button no longer lights.
7.2.7 Freezing and Releasing the Output
To freeze and release an Image in a Window:
1. If you want to preserve the Window layer priority, press the Window Select
Button.
2. Select the required Window to freeze.
3. Press the Freeze button.
The Freeze button lights and the Image freezes.
4. Press the Freeze button again.
The button no longer lights and the Image is no longer frozen.
5. If the Window Select button is lit, press the button to cancel the Window selection.
To freeze and release the background image:
1. Press the Menu button.
The Menu button lights.
2. Press the Freeze button.
The Freeze button lights and the background image freezes.
3. Press the Menu button.
The Menu button no longer lights but the background image remains frozen.
4. To release the background image press the Menu button.
The Menu button lights.
MV-5 - Configuring and Operating the MV-5 Locally 37
5. Press the lit Freeze button.
The button no longer lights and the background image is released.
6. Press the Menu button.
The Menu button no longer lights.
7.2.8 Locking and Unlocking the Front Panel Buttons
To lock and unlock the front panel buttons:
Press and hold the unlit Panel Lock button.
The LED lights and the front panel buttons are locked.
Press and hold the lit Panel Lock button.
The LED no longer lights and the front panel buttons are unlocked
Note: When the front panel is locked it is still possible to operation the device remotely.
7.2.9 Resetting the Device to Factory Default Configuration
To reset the device to the factory default configuration:
1. Turn the device off.
2. Press and hold the Reset button on the rear panel of the device.
3. While holding the button depressed, turn the device on.
4. Hold the button depressed until the Window/Input is displayed.
5. Release the button.
The configuration is reset to the factory default.
38 MV-5 - Configuring and Operating the MV-5 Locally
8 Configuring and Operating the MV-5
Remotely
This section describes:
The Multiviewer main window (see
The Menu bar (see
The Quick Access Toolbar (see
Using the MV-5 Multiviewer Software (see
Kramer offers free control software that enables you to operate the MV-5 remotely via a PC or serial controller using serial commands (see
Multiviewer software can be downloaded from www.kramerelectronics.com
.
The MV-5 can be operated remotely using the Kramer MV-5 Multiviewer software via the:
RS-232 serial port (see
RS-485 serial port (see
Ethernet port (see
The Multiviewer software requires the following:
Windows™ XP, Vista or Windows™ 7
Microsoft .Net Framework version 3.5
To install the Multiviewer software, download and then run the setup file. After installation, running the Controller software for the first time displays a window
similar to that shown in Figure 8 .
MV-5 - Configuring and Operating the MV-5 Remotely 39
8.1 The Multiviewer Main Window
Figure 8: MV-5 Controller Software Main Window
1
#
2
3
4
5
6
7
Feature Function
Menu Bar
Quick Access Toolbar
Windows Position
Operate and configure the device using the Menu Bar options (see
Operate and configure the device using the quick access toolbar buttons (see
Modify window size and position by dragging and dropping individual windows (see
Layer Order
Click and drag layers to rearrange the order of visibility
(see
Switch Windows Buttons Click on a button to select a window (see
Status:
Disconnected/Connected
Switch Inputs Buttons
Indicates whether the software is connected to or disconnected from the device (see
Click on an input button to switch the input to the selected window (see
Note: Unless the device is in off-line mode (by pressing the Take button), when a change is made on the device (for example, a different output is selected), the change is reflected almost immediately in the main window of the Controller
Software. Similarly, if a change is made in the Controller Software, the change is reflected almost immediately on the device.
40 MV-5 - Configuring and Operating the MV-5 Remotely
8.2 The Menu Bar
The menu bar options are shown in the table below.
Note: Any actions that are not valid are grayed out.
Menu Bar
Option
FILE
Sub Menu Description
DEVICE
Open
Save
Open an existing configuration
Save the current configuration
Exit
Exit the MV-5 Controller software
Connect/Disconnect Connect to or disconnect from the device (see
Take/Update
Press Take to put the device in off-line mode. Press Update to implement waiting changes and return the device to on-line mode (see
Firmware Upgrade
Update the device firmware (see
Device Details
Retrieve and display the device details, such as, model, unit name, version, and so on (see
DISPLAY
Output Resolution
Set the output resolution
Background Source
Set the background source: Colored, DVI Input
Background Color
Set the background color (see
Background Freeze
Freezes and releases the background: Off, On
SETUP
ABOUT
Image Properties
Sets the image properties, such as, brightness, contrast and labeling (see
Advanced Properties Sets the advanced image properties, such as, output standards and LCD brightness (see
Refresh
Store
Retrieves full information from the device to update the screen
Stores the current configuration in a memory preset
Recall
Recalls the configuration from a memory preset
Displays the Multiviewer Software and Kramer company details (see
8.2.1 Setting the Background Color
You can assign a preset or custom color to the background.
To modify the background color:
1. From the Menu bar, click Display > Background Color.
The Color window appears as shown in Figure 12 .
MV-5 - Configuring and Operating the MV-5 Remotely 41
Figure 9: Background Color Window
2. Select either a predefined color or define a custom color.
3. Click OK.
The background color is set.
8.2.2 Setting the Image Properties
You can set the image properties, such as, brightness, contrast and border color.
To modify the image properties:
1. From the Menu bar, click Display > Image Properties.
The Image Properties window appears as shown in Figure 10 .
42 MV-5 - Configuring and Operating the MV-5 Remotely
Figure 10: Image Properties Window
2. Select the required window to modify.
3. Modify the properties as required.
4. Click Close.
The image properties for the selected window are set.
Field
Window
Brightness
Contrast
Color
Sharpness
Transparency
Border Thickness
Border Color
Label Mode
Label Position
Description
Selects the window for which you want to change the properties
Sets the brightness of the window
Sets the Contrast of the window
Sets the color of the window
Sets the sharpness of the window
Sets the transparency of the window
Sets the border width of the window
Sets the border color of the window
Enables/disable the border label and adjusts the label properties,
(Label Disabled, Black Window Label, White Window Label, Black
Video Input Label, White Input Video Label)
Sets the position of the label in the border, (Top left, top middle, top right, bottom left, bottom middle, bottom right)
MV-5 - Configuring and Operating the MV-5 Remotely 43
8.2.3 Setting the Output Advanced Properties
You can set the output properties, such as, HD and SD formats, and output when there is no signal input.
To modify the image properties:
1. From the Menu bar, click Display > Advanced Properties.
The Advanced Properties window appears as shown in Figure 11 .
Figure 11: Advanced Properties Window
2. Modify the properties as required.
3. Click Close.
The output properties are set.
44
Field Description
Output Standard Mode Selects the output between Forced Output Standard and Auto
Defined by DVI Background Input
Analog HD Output Format Sets analog HD output format, (RGBHV, RGBS, RGsB, YUV bisync, YUV tri-sync)
Analog SD Output Format Sets the analog SD output format, (YUV SD, 3 outputs CVBS, YC and one CVBS)
No Signal Handle Mode
LCD Brightness
Sleep Mode Brightness
Sets the output when no input is present, (freeze last image, Blue screen, Black screen, Remove window)
Sets the brightness of the LCD backlighting
Sets the brightness of the LCD backlighting when the device is in sleep mode
MV-5 - Configuring and Operating the MV-5 Remotely
8.2.4 Updating the Firmware
To update the firmware:
1. Download the latest firmware file from http:www.kramerelectronics.com
.
2. Click Device > Firmware Upgrade.
3. Browse to the firmware file that you downloaded.
!
4. Click Upload.
The device firmware is loaded.
Note: Do not interrupt the uploading process or the device may be rendered inoperable.
5. When the process is complete, reboot the device.
8.2.5 Changing the Device Details
From this window you can change the device name and its IP communication parameters.
To change the device details:
1. From the Menu bar, click on Device.
The Device Details window appears as shown in Figure 12 .
MV-5 - Configuring and Operating the MV-5 Remotely 45
Figure 12: Device Details Window
2. Modify the parameters as required. For each modified parameter, click Set
Value.
3. Click Close.
Note: If you modify any of the IP parameters you must reconnect to the device with the new parameters.
8.2.6 Displaying the MV-5 Software Version Number
To display the MV-5 Software version number:
1. From the Menu bar, click About.
The About MV-5 Multiviewer Controller window appears as shown in
46 MV-5 - Configuring and Operating the MV-5 Remotely
Figure 13: About MV-5 Window
2. Click OK to close the window.
8.3 The Quick Access Toolbar
The Quick Access Toolbar is shown in Figure 14 and described in the table below.
Figure 14: Quick Access Toolbar
Feature
Open an existing project
Description
Save the current project
Connects to and disconnects from the device (see
Press Take to enable multiple off-line changes to be made. Press
Update to implement the changes (see
Freezes and releases the top window
Sets the visibility of the active window
Sets the window zoom parameters
Sets the chroma key properties
Figure 15: Quick Access Toolbar Icons
MV-5 - Configuring and Operating the MV-5 Remotely 47
8.3.1 Connecting to the Device
To connect to the device:
1. Click the Connect button.
The Connection Method window shown in Figure 16 appears.
48
Figure 16: Connection Method Window
2. Select the required method of connection radio button:
For Ethernet, enter the IP address and Port number of the device. To set the default IP address and Port number, press the Default button
For a serial connection, select the required Com port and baud rate from the drop-down lists
For a USB connection, select the required USB connection from the drop-down list
3. Click Connect.
If the connection is successful, the main window shown in Figure 8 appears.
If the connection is not successful, a Timeout error message appears.
MV-5 - Configuring and Operating the MV-5 Remotely
8.4 Using the MV-5 Multiviewer Software
8.4.1 Windows Position
The windows can be manually manipulated in size and position in the Window
Position area.
Figure 17: Windows Position
To change the size of a window:
Click, hold and drag the required window handle
To change the position of a window:
Click, hold and drag anywhere in the window
8.4.2 Window and Input Buttons
The switching configuration can be modified by clicking on the Windows and
Inputs buttons.
MV-5 - Configuring and Operating the MV-5 Remotely 49
Figure 18: Switch Buttons
3
4
5
6
7
8
1
2
# Feature
A
WINDOW Buttons
(A to D)
1
DVI INPUT 3
DVD Icon
3
Input Button
DVI INPUT 3
Function
Layer identifier (A to D)
Click to select a window to assign to an input (see
Input number (1 to 4)
Currently selected input for this window
The input icon assigned to this window (see
Input number
Click to select one of the 16 inputs
The input label assigned to this button (see
8.4.3 Device Status
The device status can be one of the following states:
Online
—the device is updated in real-time by the application, and changes to settings on the device are reflected almost immediately in the software
Online in take mode
—changes made in the application are only implemented on the device when the Update button is pressed
50 MV-5 - Configuring and Operating the MV-5 Remotely
8.4.4 Changing the Layer Order
You can modify the order in which the windows are arranged. The top layer is on
the right and the bottom layer on the left. In Figure 19 layer A is on top and layer C
is at the bottom.
Figure 19: Layer Order
To change the window layer order:
1. Click and hold on the layer that you want to move.
2. Drag the layer to the right or left into the required position and release.
The layer is placed in the required position.
8.4.5 Implementing Multiple Actions At Once
To implement multiple actions at once:
1. Press the Take button to put the device in off-line mode.
The button changes to the Update button and the device is in off-line mode.
2. Initiate the required actions, such as, switching and layer order changes.
3. Press the Update button.
The button changes to the Take button and all actions are executed.
MV-5 - Configuring and Operating the MV-5 Remotely 51
8.4.6 Switching an Input to a Window
To switch an input to a window:
1. Click on the required window button.
The window is selected, promoted to the top layer (if it wasn’t already) and
the button changes to a solid color as shown in Figure 20 .
52
Figure 20: Switching an Input to a Window
2. Click on the required Inputs button.
The input is assigned to the previously selected window and the button changes to a solid color.
MV-5 - Configuring and Operating the MV-5 Remotely
8.4.7 Changing a Window Setup
To change a window setup:
1. Right-click on the relevant Windows button.
2. The Window Setup window appears as shown in Figure 21 .
Figure 21: Windows Setup Window
3. From the Connect to Input drop-down list, select the required input.
4. Click the Freeze icon to freeze this window.
5. Click the Visibility icon to modify the visibility of this window.
MV-5 - Configuring and Operating the MV-5 Remotely 53
6. In the Size fields, adjust the width and height percentage size of the window relative to the full image.
This adjusts the size of this window.
Note: Checking the Image Aspect Enable box locks the width and height settings.
With this box checked you can change only the size and aspect ratio of the image.
7. If the Image Aspect Enable box is checked, adjust the size and aspect ratio percentages of the image.
8. In the Position fields, enter the x and y position percentage for the window relative to the original position.
This adjusts the position of this window.
9. Click OK.
The Window setup is changed.
8.4.8 Changing Input Button Properties
To change the properties of an input button:
1. Right-click on the relevant input button.
The Input Properties window appears as shown in Figure 22 .
54 MV-5 - Configuring and Operating the MV-5 Remotely
Figure 22: Input Button Properties Window
2. In the Label text box, enter the required button label.
Note: The label is limited to 10 characters.
3. Select the required icon from the list or click on the Select icon from file button and browse to the required file. The icon image should be no larger than 32 x 32 pixels and one of the following formats: BMP, JPG, GIF, PNG,
TIF, ICO.
4. Click OK.
The input button characteristics are changed.
MV-5 - Configuring and Operating the MV-5 Remotely 55
9 Upgrading the Firmware
The firmware can be uploaded either using the Web pages (see
by using the K-Upload Software. The instructions for using the K-Upload
Software can be found in the
“Upgrading the MV-5 Firmware Using the K-Upload
Software
” document available for download from http://www.kramerelectronics.com .
56 MV-5 - Upgrading the Firmware
10 Technical Specifications
INPUTS:
OUTPUTS:
JITTER:
DATA RATE:
HDMI BANDWIDTH:
COMPLIANCE WITH
HDMI STANDARD:
SUPPORTED OUTPUT
RESOLUTIONS:
4 RGB/Component HD on 20 BNC connectors
12 Analog SD on BNC connectors (12CV / 6YC / 3YC
B
C
R
)
5 DVI-D (1 as a dedicated background) on 5 DVI-I Molex 24-pin
(F) connectors
4 SDI on 4 BNC connectors
1 RGB/Component HD on 5 BNC connectors
1 DVI-D on a DVI-I Molex 24-pin (F) connector
2 SDI on 2 BNC connectors
Better than 0.2UI
Up to 2.97Gbps
Up to 6.75Gbps data rate (2.25Gbps per graphic channel)
HDCP (DVI inputs/outputs)
POWER
CONSUMPTION:
CONTROLS:
OPERATING
TEMPERATURE:
STORAGE
TEMPERATURE:
HUMIDITY:
DIMENSIONS:
WEIGHT:
INCLUDED
ACCESSORIES:
480i/60, 576i/50, 720p/50, 720p/59, 720p/60, 1080i/50,
1080i/59, 1080i/60, 1080p/23, 1080p/24, 1080p/25, 1080p/29,
1080p/30, 1080p/50, 1080p/59, 1080p/60, 1080psf/23,
1080psf/24, 1080psf/25, 1080psf/29, 1080psf/30, 640x480/60,
640x480/72, 640x480/75, 640x480/85, 800x600/60,
800x600/72, 800x600/75, 800x600/85, 1024x768/60,
1024x768/70, 1024x768/75, 1024x768/85, 1152x864/75,
1280x768/60rducBL, 1280x768/60, 1280x768/75, 1280x768/85,
1280x960/60, 1280x768/85, 1280x1024/60, 1280x1024/75,
1360x768/60, 1366x768/60, 1400x1050/60rducBL,
1400x1050/60, 1400x1050/75, 1440x900/60rducBL,
1440x900/60, 1440x900/75, 1440x900/85, 1600x1200/60,
1680x1050/60rducBL, 1680x1050/60, 1920x1200/60rducBL
100
240V AC, 50/60Hz, 57VA
Front panel buttons, RS-232, Ethernet
0° to +40°C (32° to 104°F)
–40°C to +70°C (–40° to 158°F)
10% to 90%, RHL non-condensing
19” x 9.45” x 2U (W, D, H)
2.8kg (6.17lbs) approx.
Power cord, rack ”ears”
Specifications are subject to change without notice at http://www.kramerelectronics.com
MV-5 - Technical Specifications 57
11 Default Communication Parameters
RS-232
Baud Rate:
Data Bits:
115,200
8
Stop Bits:
Parity:
Command Format: ASCII
Protocol example (Output 1 to Input 1): #AV 1>1<CR>
Ethernet
1
None
IP Address:
TCP Port #:
UDP Port #:
192.168.1.39
5000
50000
58 MV-5 - Default Communication Parameters
12 Default EDID
The MV-5 has a non-modifiable, preprogrammed EDID stored on each input.
Monitor
Model name............... MV-5
Manufacturer............. KMR
Plug and Play ID......... KMR1200
Serial number............ 505-708980100
Manufacture date......... 2011, ISO week 255
Filter driver............ None
-------------------------
EDID revision............ 1.3
Input signal type........ Digital
Color bit depth.......... Undefined
Display type............. RGB color
Screen size.............. 520 x 320 mm (24.0 in)
Power management......... Standby, Suspend, Active off/sleep
Extension blocs.......... 1 (Reserved - 0x00)
-------------------------
DDC/CI................... Not supported
Color characteristics
Default color space...... Non-sRGB
Display gamma............ 2.20
Red chromaticity......... Rx 0.674 - Ry 0.319
Green chromaticity....... Gx 0.188 - Gy 0.706
Blue chromaticity........ Bx 0.148 - By 0.064
White point (default).... Wx 0.313 - Wy 0.329
Additional descriptors... None
Timing characteristics
Horizontal scan range.... 30-83kHz
Vertical scan range...... 56-76Hz
Video bandwidth.......... 170MHz
CVT standard............. Not supported
GTF standard............. Not supported
Additional descriptors... None
Preferred timing......... Yes
Native/preferred timing.. 1280x720p at 60Hz (16:10)
Modeline............... "1280x720" 74.250 1280 1390 1430 1650 720 725 730 750 +hsync +vsync
Standard timings supported
720 x 400p at 70Hz - IBM VGA
640 x 480p at 60Hz - IBM VGA
640 x 480p at 75Hz - VESA
800 x 600p at 60Hz - VESA
800 x 600p at 75Hz - VESA
1024 x 768p at 60Hz - VESA
1024 x 768p at 75Hz - VESA
1280 x 1024p at 75Hz - VESA
1280 x 1024p at 60Hz - VESA STD
1600 x 1200p at 60Hz - VESA STD
1152 x 864p at 75Hz - VESA STD
Report information
Date generated........... 14-Jul-14
Software revision........ 2.60.0.972
Data source.............. Real-time 0x0100
Operating system......... 6.1.7601.2.Service Pack 1
Raw data
00,FF,FF,FF,FF,FF,FF,00,2D,B2,00,12,01,01,01,01,FF,15,01,03,80,34,20,78,EA,B3,25,AC,51,30,B4,26,
10,50,54,A5,4B,00,81,80,A9,40,71,4F,01,01,01,01,01,01,01,01,01,01,01,1D,00,72,51,D0,1E,20,6E,28,
55,00,07,44,21,00,00,1E,00,00,00,FF,00,35,30,35,2D,37,30,38,39,38,30,31,30,30,00,00,00,FC,00,4D,
56,2D,35,00,00,00,00,00,00,00,00,00,00,00,00,FD,00,38,4C,1E,53,11,00,0A,20,20,20,20,20,20,01,C2
MV-5 - Default EDID 59
13 Kramer Protocol 3000
The MV-5 can be operated using serial commands from a PC, remote controller or touch screen using the Kramer Protocol 3000.
This section describes:
Kramer Protocol 3000 syntax (see Section
Kramer Protocol 3000 commands (see Section
13.1 Kramer Protocol 3000 Syntax
13.1.1 Host Message Format
Start Address (optional)
#
device_id@
Body
Message
13.1.2 Simple Command
Delimiter
CR
Start
#
Command string with only one command without addressing:
Body
Command SP
Parameter_1,Parameter_2,…
Delimiter
CR
13.1.3 Command String
Formal syntax with commands concatenation and addressing:
Start Address
#
device_id@
Body
Command_1
Parameter1_1,Parameter1_2,…|
Command_2
Parameter2_1,Parameter2_2,…|
Command_3
Parameter3_1,Parameter3_2,…|…
Delimiter
CR
13.1.4 Device Message Format
Start Address (optional)
~
device_id@
Body
Message delimiter
CR LF
60 MV-5 - Kramer Protocol 3000
13.1.5 Device Long Response
Echoing command:
Start Address (optional)
~
device_id@
Body
Command SP [
Param1 ,Param2 …] result
CR = Carriage return (ASCII 13 = 0x0D)
LF = Line feed (ASCII 10 = 0x0A)
SP = Space (ASCII 32 = 0x20)
13.1.6 Command Terms
Delimiter
CR LF
Command
A sequence of ASCII letters ('A'-'Z', 'a'-'z' and '-').
Command and parameters must be separated by at least one space.
Parameters
A sequence of alphanumeric ASCII characters ('0'-'9','A'-'Z','a'-'z' and some special characters for specific commands). Parameters are separated by commas.
Message string
Every command entered as part of a message string begins with a message
starting character and ends with a message closing character.
Note: A string can contain more than one command. Commands are separated by a pipe ( '|' ) character.
Message starting character
'#'
– For host command/query
'~'
– For device response
Device ID (Optional, for K-NET)
K-NET Device ID followed by '@'
Query sign
'?' follows some commands to define a query request.
Message closing character
CR
– For host messages; carriage return (ASCII 13)
CRLF
– For device messages; carriage return (ASCII 13) + line-feed (ASCII 10)
MV-5 - Kramer Protocol 3000 61
Command chain separator character
When a message string contains more than one command, a pipe ( '|' ) character separates each command.
Spaces between parameters or command terms are ignored.
13.1.7 Entering Commands
You can directly enter all commands using a terminal with ASCII communications software, such as HyperTerminal, Hercules, etc. Connect the terminal to the serial or Ethernet port on the Kramer device. To enter CR press the Enter key.
( LF is also sent but is ignored by command parser).
For commands sent from some non-Kramer controllers like Crestron, some characters require special coding (such as, /X##). Refer to the controller manual.
13.1.8 Command Forms
Some commands have short name syntax in addition to long name syntax to allow faster typing. The response is always in long syntax.
13.1.9 Chaining Commands
Multiple commands can be chained in the same string. Each command is delimited by a pipe character (“|”). When chaining commands, enter the message
starting character and the message closing character only once, at the beginning of the string and at the end.
Commands in the string do not execute until the closing character is entered.
A separate response is sent for every command in the chain.
13.1.10 Maximum String Length
64 characters
62 MV-5 - Kramer Protocol 3000
13.2 Kramer Protocol 3000 Commands
13.2.1 Common Commands
Command
#
BUILD-DATE?
ETH-PORT
ETH-PORT?
FACTORY
HELP
LOCK-FP
LOCK-FP?
MACH-NUM
MODEL?
NAME
NAME?
NAME-RST
NET-DHCP
NET-DHCP?
NET-GATE
NET-GATE?
NET-IP
NET-IP?
NET-MAC?
NET-MASK
NET-MASK?
PROT-VER?
PRST-RCL
RESET
SN?
UPGRADE
VERSION?
Description
Protocol handshaking
Read device build date
Change protocol Ethernet port
Query protocol Ethernet port
Reset to factory default configuration
List of commands
Lock front panel
GET Lock front panel
Set Machine number
Read device model
Set machine (DNS) name
Query machine (DNS) name
Reset machine name to factory default (DNS)
Set DHCP mode
Query DHCP mode
Set Gateway
Query Gateway
Set IP address
Query IP address
Query MAC address
Set subnet mask
Query subnet mask
Read device protocol version
Read saved preset list (see Note below)
Reset device
Read device serial number
Execute firmware upgrade
Read device firmware version
13.2.2 Device Specific Commands
Set Command syntax
Y Control_Type=0, Function#, Param
For example:
#Y 0,212,1
MV-5 - Kramer Protocol 3000 63
Device response:
~id=01Y Control_Type=0,Function#,Param
For example:
~01@Y 0,212,1
Get Command syntax
Y Control_Type=1, Function
For example:
#Y 1,200
Device response:
~id=01Y Control_Type=1, Function, Param
For example:
~01@Y 1,200,3
The following table lists the MV-5
“Y commands”. If a parameter in the table is given as multidimensional vector (for example, IN_FRMT[4] - has the dimension =
4), this signifies that there are four different parameters each of which reflect a state of the same feature for different inputs or different windows. In order to address the required input or window, one more parameter must be added to the
“Y command”- the fourth for “Set Command” and third for “Get Command”. For example “#Y 0,103,25,2” signifies “Set Command, function = 103 (Pixel Latch
Phase = PX_PHS[2]), Value = 25, only for Analog HD INPUT # 3 (as here additional parameter A = 2, this corresponds to INPUT # = A + 1). Another example: “#Y 0,303,-50,0” - signifies “Set Command, function = 303 (Window H size = HSZ_H[0]), Value = -50, only for WINDOW # 1 (as here additional parameter A = 0, this corresponds to WINDOW # = A + 1). The Notes column indicates whether the additional parameter is related to a window or to an input.
Description
Analog HD Input format
Function #
100
Parameter
IN_FRMT[4]
Value
0
1
2
3
Notes
RGBHV (additional parameter defines HD input
RGBS
RGsB
YUV (bi-sync or tri-sync auto definition)
64 MV-5 - Kramer Protocol 3000
Description
Horizontal start pixel
Function #
101
Vertical start line 102
103
Parameter
H_STRT[4]
Pixel latch phase
SD button input assignment
DVI inputs
HDCP capability
104
105
V_STRT[4]
PX_PHS[4]
SDBTN[4]
HDCP_IN[5]
Output Video
Resolution
200
MV-5 - Kramer Protocol 3000
OUT_RSL 0
1
2
3
8
9
10
11
4
5
6
7
12
13
14
15
14
15
16
17
10
11
12
13
18
19
20
4
5
6
7
0
1
2
3
8
9
0
1
Value
[-100:+100]
[-50:+50]
[0:31]
Notes
Additional parameter defines analog HD input
Additional parameter defines analog HD input
Additional parameter defines analog HD input
Analog CV1 input
Analog CV2 input
Analog CV3 input
Analog CV4 input
Analog CV5 input
Analog CV6 input
Analog CV7 input
Analog CV8 input
Analog CV9 input
Analog CV10 input
Analog CV11 input
Analog CV12 input
Analog YC1 input
Analog YC2 input
Analog YC3 input
Analog YC4 input
Analog YC5 input
Analog YC6 input
Analog YUV1 input
Analog YUV2 input
Analog YUV3 input
DVI input# is HDCP capable
DVI input# is HDCP non-capable
Additional parameter defines DVI
Input. HDCP_IN[4]
– for DVI background input
480i/60
576i/50
720p/50
720p/59
720p/60
1080i/50
1080i/59
1080i/60
1080p/23
1080p/24
1080p/25
1080p/29
1080p/30
1080p/50
1080p/59
1080p/60
65
Top Layer fit in the screen
Description
Cropping
Preview
Analog HD output format
66
CROP_PVW
Parameter
OUT_HD_FR
MT
202
201
Function #
0
1
2
3
49
50
51
52
45
46
47
48
53
54
0
1
36
37
38
39
32
33
34
35
40
41
42
43
44
24
25
26
27
20
21
22
23
28
29
30
31
Value
16
17
18
19
2
Notes
1080sf/23
1080sf/24
1080sf/25
1080sf/29
1080sf/30
640x480/60
640x480/72
640x480/75
640x480/85
800x600/60
800x600/72
800x600/75
800x600/85
1024x768/60
1024x768/70
1024x768/75
1024x768/85
1152x864/75
1280x768/60 reduced blanking
1280x768/60
1280x768/75
1280x768/85
1280x960/60
1280x960/85
1280x1024/60
1280x1024/75
1360x768/60
1366x768/60
1400x1050/60 reduced blanking
1400x1050/60
1400x1050/75
1440x900/60 reduced blanking
1440x900/60 reduced blanking
1440x900/75
1440x900/85
1600x1200/60
1680x1050/60 reduced blanking
1680x1050/60
1920x1200/60 reduced blanking
Normal windows size and position
Top Layer window Image is fit in the screen
The cropping border arises
RGBHV
RGBS
RGsB
YUV bi-sync
MV-5 - Kramer Protocol 3000
Description
Analog SD output format
Background image source
Background color RED
Background color GREEN
Background color BLUE
Background freeze
Analog Output
Sync mode Only For
720p, 1080i,
1080p in case of
RGBHV
Output Format
Function #
203
204
205
206
207
208
209
RGB Out Hsync position
RGB Out Vsync position
DVI OUTPUT
HDCP
MODE
210
211
212
Parameter
OUT_SD_FR
MT
BG_MODE
BG_RED
BG_GREEN
BG_BLUE
BG_FRZ
OUT_SNC_M
ODE
OUT_H_POS
OUT_V_POS
1
2
[-75;75]
[-1;7]
HDCP_OUT 0
1
1
2
0
Value
4
0
1
[0:255]
[0:255]
[0:255]
0
1
0
DVI OUTPUT
HDCP
STATUS
213
Window input source
SELECT
300
MV-5 - Kramer Protocol 3000
2
3
OUT_STATUS 0
WND_INP[4]
3
0
1
2
3
1
2
Notes
YUV tri-sync
YUV SD
Three outputs CVBS
YC and one CVBS
Colored background field
DVI background input
Active only if BG_MODE = 0
Active only if BG_MODE = 0
Active only if BG_MODE = 0
No freeze background
Freeze background
Analog output sync meets the CEA
Standard
RGBHV format (H - pos, V - pos)
INVERS1: H- neg, V - neg
INVERS2: H- neg, V - neg, H advanced
H sync position (for RGBHV,
RGBS, RGsB)
V sync position (for RGBHV,
RGBS, RGsB)
DVI Output HDCP "FOLLOW
INPUT"
DVI Output HDCP "FOLLOW
OUTPUT"
HDCP on Output "ON"
HDCP on Output "OFF"
Output forced to non-encrypted
(NO HDCP)
MV-5 tries to set HDCP link, but acceptor don't support HDCP.
Encryption turn OFF
HDCP active (monitor supports
HDCP)
DVI output HDCP is ACTIVE, but
SDI and
Analog outputs are disabled
DVI1 input (additional parameter defines a window)
DVI2 input
DVI3 input
DVI4 input
67
Description
Window Input
Resolution
(READ ONLY)
INP_RES[0] - window 1
INP_RES[1] - window 2
INP_RES[2] - window 3
INP_RES[3] - window 4
INP_RES[4] - reflects background input status
68
Parameter
INP_RSL[5]
Function #
301
3
4
5
12
13
14
15
8
9
10
11
Value
4
5
6
7
0
1
2
6
7
22
23
24
25
18
19
20
21
26
27
28
29
30
12
13
14
15
8
9
10
11
16
17
Notes
SDI1 input
SDI2 input
SDI3 input
SDI4 input
Analog HD1 input
Analog HD2 input
Analog HD3 input
Analog HD4 input
Analog SD1 button
Analog SD2 button
Analog SD3 button
Analog SD4 button
480i/60 INP_RSL[4] - background
576i/50
720p/50
720p/59
720p/60
1080i/50
1080i/59
1080i/60
1080p/23
1080p/24
1080p/25
1080p/29
1080p/30
1080p/50
1080p/59
1080p/60
1080sf/23
1080sf/24
1080sf/25
1080sf/29
1080sf/30
640x480/60
640x480/72
640x480/75
640x480/85
800x600/60
800x600/72
800x600/75
800x600/85
1024x768/60
1024x768/70
MV-5 - Kramer Protocol 3000
Description
Window priority 302 definition
Function # Parameter
W_PRIO[4]
Window H size
Window V size
Window aspect 305
303
304 enable
WSZ_H[4]
WSZ_V[4]
W_ASP_EN[4] 0
[-90:0]
[-90:0]
1
0
1
2
3
4
39
40
41
42
35
36
37
38
43
44
45
46
51
52
53
54
47
48
49
50
55
56
Value
31
32
33
34
MV-5 - Kramer Protocol 3000
Notes
1024x768/75
1024x768/85
1152x864/75
1280x768/60 reduced blanking
1280x768/60
1280x768/75
1280x768/85
1280x960/60
1280x960/85
1280x1024/60
1280x1024/75
1360x768/60
1366x768/60
1400x1050/60 reduced blanking
1400x1050/60
1400x1050/75
1440x900/60 reduced blanking
1440x900/60 reduced blanking
1440x900/75
1440x900/85
1600x1200/60
1680x1050/60 reduced blanking
1680x1050/60
1920x1200/60 reduced blanking
UNIDENTIFIED INPUT SIGNAL
NO INPUT SIGNAL
Window disappears
Upper (top) layer window
Window after upper layer
Next window
Lower layer window, can be overlapped by all others
If WSZ_H = 0 - window width fit in the screen 100%
If WSZ_H = -90 - window width =
10% of screen
width. Step = 1%
If WSZ_V = 0 - window height fit in the screen 100%;
If WSZ_V = -90 - window height =
10% screen height.
Step = 1%
H and V window sizes are defined independently
by WSZ_H and WSZ_V
Parameter WSZ_H affects simultaneously H and
V window size, but the relation between H and V
69
Window V position
Image H size
Image V size
70
Description
306
307
Window Aspect ratio
Window H position
Function # Parameter
WIN_ASP[4]
WPOS_H[4]
308
309
310
WPOS_V[4]
IMSZ_H[4]
IMSZ_V[4]
Value
[-75:75]
[0:1000]
[0:1000]
[0:900]
[0:900]
Notes
sizes is defined by next parameter:
WIN_ASP
If WIN_ASP = 0 - window aspect is equal to original screen aspect (100%), namely:
Real window WIDTH(%) = WSZ_H
+ 100;
HEIGHT(%) = WSZ_H + 100
If WIN_ASP > 0 then as above, window WIDTH(%) = WSZ_H +
100, but the height is reduced accordingly the formula :
HEIGHT(%)= (WSZ_H+100) * 100 /
/ (WIN_ASP + 100) (window is like letterbox)
If WIN_ASP < 0 then window
HEIGHT(%) = WSZ_H + 100, but the width is reduced accordingly the formula
:WIDTH(%) =
(WSZ_H+100) * (100 + WIN_ASP) /
100
(window is like pillarbox)
Defines X coordinate of top left corner of window
normalized relatively screen width
(Step = 0.1%)
represented in percent of screen width * 10
Defines Y coordinate of top left corner of window
normalized relatively screen height. Step = 0.1% represented in percent of screen height * 10
Defines H size of image relatively window H size
(i.e. H ZOOM) Step = 1% If
IMSZ_H = 0 then image is exactly fits to window width.
If IMSZ_H > 0 then real
IM_WIDTH(%) = (IMSZ_H + 100) window WIDTH
Image is cropped. If IMSZ_H = 900, then set maximal H ZOOM = 1000%
Defines V size of image relatively window V size
(i.e. V ZOOM) Step = 1% If
IMSZ_V = 0 then
MV-5 - Kramer Protocol 3000
Description
Image aspect enable
Image Aspect ratio
Image position
H relatively window (H panorama)
Image position
V relatively window (Vertical panorama)
314
312
313
311
Function # Parameter
IM_ASP_EN[4
]
0
1
Value
[-50:100 ] IM_ASP[4]
IMPOS_H[4] [0:1000]
Window border thickness
Window border color R
Window border color G
Window border color B
Window image brightness
Window image contrast
Window image color
315
316
317
318
319
320
321
MV-5 - Kramer Protocol 3000
IMPOS_V[4] [0:1000]
BRD_THKN[4] [0:20]
BRD_RED[4] [0:255]
BRD_GREEN[
4]
[0:255]
BRD_BLUE[4] [0:255]
BRIGHT[4] [-50:50]
CONTRAST[4] [-50:50]
COLOR[4] [-100:50]
Notes
image is exactly fits to window height.
If IMSZ_V > 0 then real
IM_HEIGHT(%)=(IMSZ_V + 100) In this case the image is cropped.
H and V image sizes are defined independently
by IMSZ_H and IMSZ_V
Parameter IMSZ_H affects simultaneously
H and V image size, but the relation between
H and V sizes is defined by parameter: IM_ASP
If IM_ASP = 0 - image aspect is equal to original input image aspect (100%)
If IM_ASP = -50 then aspect= 0.5 of original
If IM_ASP = +100 then aspect = 2.0 of original
Defines shift of image to the left with cropping
of image left side, measured in percent of original image width.
Step = 0.1%.
Allows image H panorama in case of ZOOM
Defines shift of image to the bottom with
cropping of image bottom side, measured in percent of original image height.
Step = 0.1%.
Allows image V panorama in case of ZOOM
If BRD_THKN = 0 then border is
OFF
If BRIGHT = 0 then default brightness (100%)
If CONTRAST = 0 then default contrast (100%)
If COLOR = 0 then default color(100%).
If SHARP = 0 - no sharpness,
71
Window Label
Mode
Label Position
TEST signal
Description
Window image sharpness
Window freeze image
Window keyer enable
Window keyer threshold Y min
Window keyer threshold Y max
Window keyer threshold U min
Window keyer threshold U max
Window keyer threshold V min
Window keyer threshold V max
Window image transparency
Function #
322
323
324
325
326
327
328
329
330
331
Parameter
SHARP[4]
Value
[0:15]
FREEZE[4] 0
1
KEYER_EN[4] 0
1
YKEY_MIN[4] [0:255]
YKEY_MAX[4]
UKEY_MIN[4]
UKEY_MAX[4]
VKEY_MIN[4]
VKEY_MAX[4]
W_TRNSP[4]
[0:255]
[0:255]
[0:255]
[0:255]
[0:255]
[0:255]
332
333
334
LBL_MODE[4]
LBL_POS[4]
TEST[4]
0
1
0
1
2
3
4
5
0
1
2
3
2
3
4
Notes
if = 15, then max sharpness 150%
Step = 10%
No freeze window image
Freeze window image
Keyer disable
Keyer enable
If W_TRNSP = 0 then window image is non-transparent. If W_TRNSP > 0 then the transparency increases and if it equal to 255 then image disappears
Label Disabled
BLACK Label attributed to specific window
WHITE Label attributed to specific window
BLACK Label corresponds to video input
WHITE Label corresponds to video input
Bottom left location of label
Bottom center location
Bottom right location
Top left
Top center
Top right
No TEST signal; Input signal is selected for window, if available
COLOR BARS 100%
Split COLOR BARS 100%
Y RAMP 100 %
72 MV-5 - Kramer Protocol 3000
Description
Window input
HDCP
STATUS (READ
ONLY)
Function #
335
WND_HDCP[4] for background
No input signal handle mode
LCD brightness
400
401
LCD brightness in sleep
Panel Lock
402
403
Parameter
WND_HDCP[5
]
Value
0
1
2
NOSIG_HNDL 0
LCD_BRGHT
LCD_SLEEP
PLOCK
1
2
3
[-100:0]
[-100:0]
0
1
Notes
Source is not protected HDCP or this input
is forced to be HDCP incompatible
Input HDCP is active, but the window is removed or blanked due to HDCP mode settings
Input HDCP is active and this window is present on output image (HDCP monitor only)
BLACK SCREEN
BLUE SCREN
Remove window
Freeze last picture
LCD brightness while keyboard activated
If LCD_BRGHT=0 - brightness =
100%
LCD brightness in sleep mode
(after 2 min
keyboard is non-activated)
No Lock FP
Lock Panel
MV-5 - Kramer Protocol 3000 73
For the latest information on our products and a list of Kramer distributors, visit our Web site where updates to this user manual may be found.
We welcome your questions, comments, and feedback.
Web site: www.kramerelectronics.com
E-mail: [email protected]
!
SAFETY WARNING
Disconnect the unit from the power supply before opening and servicing
Rev: 4 P/N: 2900- 300134
ดาวน์โหลด