Home LiftMaster RSL12UL Residential / Light Commercial Slide Gate Installation Guide
Add to My manuals52 Pages
advertisement
![Home LiftMaster RSL12UL Residential / Light Commercial Slide Gate Installation Guide | Manualzz Home LiftMaster RSL12UL Residential / Light Commercial Slide Gate Installation Guide | Manualzz](http://s1.manualzz.com/store/data/070111076_1-1e280224ea9c5d952120d0928e4f2803-360x466.png)
RESIDENTIAL DC
VEHICULAR SLIDE GATE OPERATOR
INSTALLATION MANUAL
OPERATOR REQUIRES A
LIFTMASTER EXTERNAL
MONITORED ENTRAPMENT
PROTECTION DEVICE BE
INSTALLED IN ALL ENTRAPMENT
ZONES
THIS PRODUCT IS TO BE INSTALLED AND
SERVICED BY A TRAINED GATE SYSTEMS
TECHNICIAN ONLY.
This model is for use on vehicular passage gates ONLY and not intended for use on pedestrian passage gates.
This model is intended for use in Class I and II vehicular slide gate applications.
• Visit LiftMaster.com to locate a professional installing dealer in your area.
•
®
and Security+ 2.0
®
accessories.
Access installation and technical support guides or register this product
1.
2.
Take a photo of the camera icon including the points ( ).
Send it in by texting the photo to 71403.
RSL12ULTECH
LiftMaster
300 Windsor Drive
Oak Brook, IL 60523
TABLE OF CONTENTS
SAFETY 2
Safety Symbol and Signal Word Review ................................................2
Usage Class ...........................................................................................3
UL325 Entrapment Protection Requirements ........................................3
Safety Installation Information ...............................................................4
Gate Construction Information ...............................................................5
Erase Gateway .....................................................................................26
Erase All Transmitter and Keypad Codes .............................................26
Erase limits ..........................................................................................26
Constant Pressure Override (CPO) ......................................................26
Gate hold open feature .........................................................................26
To Remove and Erase Monitored Entrapment Protection Devices .......26
OPERATION 27
INTRODUCTION 6
Carton Inventory ....................................................................................6
Operator Specifications ..........................................................................7
Site Preparation .....................................................................................8
INSTALLATION 9
Types of Installations .............................................................................9
Step 1 Determine Location for Operator ..............................................10
Step 2 Install the Operator ...................................................................11
Step 3 Attach the Chain .......................................................................12
Step 4 Install Entrapment Protection ...................................................13
Step 5 Earth Ground Rod .....................................................................15
Step 6 Power Wiring ............................................................................15
Step 7 Install the cover ........................................................................18
ADJUSTMENT 19
Adjust the Limits and Automatic Force ................................................19
Manual Adjustments ............................................................................19
Enter Manual Setup Mode ...................................................................20
Reversal Force Dial ..............................................................................20
Set the Limits .......................................................................................20
Automatic Force ...................................................................................21
Fine Tune the Limits ............................................................................21
Fine Tune the Force .............................................................................21
Obstruction Test .................................................................................21
Control board overview ........................................................................27
Reset Switch ........................................................................................28
Manual Disconnect ..............................................................................28
Operator alarm .....................................................................................28
Remote control ....................................................................................28
ACCESSORY WIRING 29
External control devices .......................................................................29
Locks ...................................................................................................30
Miscellaneous wiring ...........................................................................30
MAINTENANCE 31
Important Safety Instructions ..............................................................31
Maintenance Chart ...............................................................................31
Batteries ...............................................................................................32
Drive Train ...........................................................................................32
TROUBLESHOOTING 33
Diagnostic Codes .................................................................................33
Diagnostic Codes Table .......................................................................34
Control Board LEDs .............................................................................36
Troubleshooting Chart .........................................................................37
APPENDIX 40
Dual gate settings ................................................................................40
Step 6 Solar Panel(s) ...........................................................................41
Manual Adjustments with a Remote Control .......................................45
DUAL GATE SETUP 22
Wired ...................................................................................................22
Wireless ...............................................................................................22
WIRING DIAGRAM 46
PROGRAMMING 24
Remote Controls (Not Provided) .........................................................24
LiftMaster Internet Gateway (not provided) .........................................26
REPAIR PARTS 47
ACCESSORIES 48
WARRANTY 50
SAFETY
Safety Symbol and Signal Word Review
When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of Serious Injury or Death if you do not comply with the warnings that accompany them. The hazard may come from something mechanical or from electric shock.
Read the warnings carefully.
When you see this Signal Word on the following pages, it will alert you to the possibility of damage to your gate and/or the gate operator if you do not comply with the cautionary statements that accompany it. Read them carefully.
IMPORTANT NOTE:
BEFORE attempting to install, operate or maintain the operator, you must read and fully understand this manual and follow all safety instructions.
DO NOT attempt repair or service of your gate operator unless you are an Authorized
Service Technician.
MECHANICAL
ELECTRICAL
WARNING: This product can expose you to chemicals including lead, which are known to the State of California to cause cancer or birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
.
2
SAFETY
Usage Class
Class I - Residential Vehicular Gate Operator
A vehicular gate operator (or system) intended for use in garages or parking areas associated with a residence of one-to four single families.
Class II - Commercial/General Access Vehicular
Gate
A vehicular gate operator (or system) intended for use in a commercial location or building such as a multi-family housing unit (five or more single family units), hotel, garages, retail store, or other buildings accessible by or servicing the general public.
Class III - Industrial/Limited Access Vehicular
Gate
A vehicular gate operator (or system) intended for use in an industrial location or building such as a factory or loading dock area or other locations not accessible by or intended to service the general public.
Class IV - Restricted Access Vehicular Gate
Operator
A vehicular gate operator (or system) intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel.
UL325 Entrapment Protection Requirements
• A minimum of two independent* monitored entrapment protection devices are required to be installed at each entrapment zone
• Every installation is unique. It is the responsibility of the installer to install external monitored entrapment protection devices in each entrapment zone
• This vehicular slide gate operator will operate only after installation of a minimum of two independent* monitored entrapment protection devices in each direction: two in the open direction and two in the close direction.
• Entrapment protection device types include inherent
(built into the operator), monitored external photoelectric sensors or monitored external edge sensors
• This operator is provided with an inherent entrapment protection device built into the operator that serves as one of the two independent devices
* Independent - the same type of device shall NOT be used for both entrapment protection devices.
IMPORTANT SAFETY
INSTRUCTIONS
To reduce the risk of INJURY or DEATH:
• READ AND FOLLOW ALL INSTRUCTIONS.
• NEVER let children operate or play with gate/door controls. Keep the remote control away from children.
• ALWAYS keep people and objects away from the gate/door. NO ONE SHOULD
CROSS THE PATH OF THE MOVING GATE/DOOR.
• Test the gate/door operator monthly. The gate/door MUST reverse on contact with an object or reverse when an object activates the noncontact sensors. After adjusting the force or the limit of travel, retest the gate/door operator. Failure to adjust and retest the operator properly can increase the risk of INJURY or
DEATH.
• Use the emergency release ONLY when the gate/door is closed. Use caution when using this release when the gate/door is open. Weak or broken springs may cause the gate/door to fall rapidly, causing severe INJURY or DEATH.
• KEEP GATES/DOORS PROPERLY OPERATING AND BALANCED. Read the gate/door manufacturer's owner’s manual. An improperly operating or balanced gate/door could cause severe INJURY or DEATH. Have a qualified service person make repairs to gate/door hardware. Have trained gate/door systems technician make repairs to cables, spring assemblies, and other hardware.
•
• The entrance is for vehicles ONLY. Pedestrians MUST use separate entrance.
SAVE THESE INSTRUCTIONS.
3
SAFETY
Safety Installation Information
1. Vehicular gate systems provide convenience and security. Gate systems are comprised of many component parts. The gate operator is only one component. Each gate system is specifically designed for an individual application.
2. Gate operating system designers, installers and users must take into account the possible hazards associated with each individual application. Improperly designed, installed or maintained systems can create risks for the user as well as the bystander. Gate systems design and installation must reduce exposure to potential hazards.
3. A gate operator can create high levels of force in its function as a component part of a gate system. Therefore, safety features must be incorporated into every gate system design. Specific safety features include:
• Edges Sensors (contact)
• Guards for Exposed Rollers
• Photoelectric Sensors
• Screen Mesh
• Instructional and Precautionary Signage
4. Install the gate operator only when: a. The operator is appropriate for the construction and the usage class of the gate.
b. All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 6 feet (1.8 m) above the ground to prevent a 2-1/4 inches (6 cm) diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position.
c. All exposed pinch points are eliminated or guarded, and guarding is supplied for exposed rollers.
5. The gate operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening. The pedestrian access opening shall be designed to promote pedestrian usage. Locate the pedestrian access such that persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate.
6. The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment.
7. The gate must be properly installed and work freely in both directions prior to the installation of the gate operator.
8. Permanently mounted access controls intended for users to activate, must be located at least 6 feet (1.8 m) away from any moving part of the gate and where the user is prevented from reaching over, under, around or through the gate to operate the controls. Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use. Exception: Emergency access controls only accessible by authorized personnel (e.g. fire, police) may be placed at any location in the line-of-sight of the gate.
9. For a gate operator utilizing a Stop and/or Reset button, it must be located in the line-of-sight of the gate. Activation of the reset control shall not cause the operator to start.
10. A minimum of two (2) WARNING SIGNS shall be installed in the area of the gate. Each warning sign is to be visible by persons located on the side of the gate on which the sign is installed.
11. For a gate operator utilizing a non-contact sensor: a. See Install Entrapment Protection section for placement of noncontact sensor for each type of application.
b. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the gate is still moving.
c. One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable by a moving gate or barrier.
12. For a gate operator utilizing a contact sensor such as an edge sensor: a. One or more contact sensors shall be located where the risk of entrapment or obstruction exists, such as at the leading edge, trailing edge and post mounted both inside and outside of a vehicular horizontal slide gate.
b. A hard wired contact sensor shall be located and its wiring arranged so the communication between the sensor and the gate operator is not subject to mechanical damage.
c. A wireless device such as one that transmits radio frequency (RF) signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstruction. A wireless device shall function under the intended end-use conditions.
4
SAFETY
Gate Construction Information
Vehicular gates should be installed in accordance with ASTM F2200: Standard Specification for Automated Vehicular Gate Construction. For a copy, contact ASTM directly at 610-832-9585 or www.astm.org.
1.
General Requirements
1.1
1.2
1.3
1.4
1.5
1.6
1.7
Gates shall be constructed in accordance with the provisions given for the appropriate gate type listed, refer to ASTM
F2200 for additional gate types.
Gates shall be designed, constructed and installed to not fall over more than 45 degrees from the vertical plane, when a gate is detached from the supporting hardware.
Gates shall have smooth bottom edges, with vertical bottom edged protrusions not exceeding 0.50 inches (12.7 mm) when other than the exceptions listed in ASTM F2200.
The minimum height for barbed tape shall not be less than 8 feet (2.44 m) above grade and for barbed wire shall not be less than 6 feet (1.83 m) above grade.
An existing gate latch shall be disabled when a manually operated gate is retrofitted with a powered gate operator.
A gate latch shall not be installed on an automatically operated gate.
Protrusions shall not be permitted on any gate, refer to ASTM
F2200 for Exceptions.
1.8
Gates shall be designed, constructed and installed such that their movement shall not be initiated by gravity when an automatic operator is disconnected, in accordance with the following.
1.8.1
Vehicular horizontal slide gate shall not result in continuous, unimpeded movement in either lineal direction of its travel.
1.9
For pedestrian access in the vicinity of an automated vehicular gate, a separate pedestrian access shall be provided or available. The pedestrian access shall be installed in a location such that a pedestrian shall not come in contact with a moving vehicular access gate during the entire path of travel of the vehicular gate. A pedestrian gate shall not be incorporated into an automated vehicular gate panel.
2.
2.1
3.
Vehicular Horizontal Slide Gates
3.1
The following provisions shall apply to Class I, Class II and Class III vehicular horizontal slide gates:
3.1.1
All weight bearing exposed rollers 8 feet (2.44 m), or less, above grade shall be guarded or covered.
3.1.2
All openings shall be designed, guarded, or screened from the bottom of the gate to the top of the gate or a minimum of 6 ft.
(1.83 m) above grade, whichever is less, to prevent a 2 1⁄4 in.
(57 mm) diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position. The gate panel shall include the entire section of the moving gate, including any back frame or counterbalance portion of the gate.
3.1.3
A gap, measured in the horizontal plane parallel to the roadway, between a fixed stationary object nearest the roadway, (such as a gate support post) and the gate frame when the gate is in either the fully open position or the fully closed position, shall not exceed
2-1/4 inches (57 mm). Exception: All other fixed stationary objects greater than 16 in. (406 mm) from the gate frame shall not be required to comply with this section.
3.1.4
Positive stops shall be required to limit travel to the designed fully open and fully closed positions. These stops shall be installed at either the top of the gate, or at the bottom of the gate where such stops shall horizontally or vertically project no more than is required to perform their intended function.
3.1.5
All gates shall be designed with sufficient lateral stability to assure that the gate will enter a receiver guide, refer to ASTM F2200 for panel types.
3.2
The following provisions shall apply to Class IV vehicular horizontal slide gates:
3.2.1
All weight bearing exposed rollers 8 feet (2.44 m), or less, above grade shall be guarded or covered.
3.2.2
Positive stops shall be required to limit travel to the designed fully open and fully closed positions. These stops shall be installed at either the top of the gate, or at the bottom of the gate where such stops shall horizontally or vertically project no more than is required to perform their intended function.
2.2
2.3
2.4
Specific Applications
Any non-automated gate that is to be automated shall be upgraded to conform to the provisions of this specification.
This specification shall not apply to gates generally used for pedestrian access and to vehicular gates not to be automated.
When the gate operator requires replacement, the existing gate shall be upgraded to conform to the provisions of this specification.
When the gate of an automated gate system requires replacement, the new gate shall conform to the provisions of this specification.
5
INTRODUCTION
Carton Inventory
NOT SHOWN: Documentation Packet, Chain #41 - 30 feet, Eye Bolt Kit
Operator
Cover
LiftMaster Monitored Retro-Reflective Photoelectric Sensor Model LMRRUL
5 ft. Edge sensor kit
Warning Signs (2) and Warranty Card
Battery 12 Vdc 7AH
6
INTRODUCTION
Operator Specifications
Usage Classification
Main AC Supply
System Operating Voltage
Accessory Power
Solar Power Max
Maximum Gate Weight
Minimum Gate Travel Distance
Maximum Gate Travel Distance
Maximum Gate Travel Speed
Maximum Daily Cycle Rate
Maximum Duty Cycle
Operating Temperature
Expansion Board
External Entrapment Protection Device Inputs (noncontact and/or contact)
Class I & II
120 Vac, .5 Amps (6.5 Amps including Accessory Outlets)
12 Vdc Battery Run / Battery Backup
12 Vdc, 500mA max. for ON + SW (switched)
12 Vdc at 30 watts max.
800 lbs (363.6 kg)
25 feet (7.62 m)
50 feet (15.24 m)
12 inches/second
120 cycles/day
Continuous
Without Heater: -20°C to 60°C (-4°F to 140°F)
With Optional Heater: -40°C to 60°C (-40°F to 140°F)
Optional
Main board - up to 2 close entrapment protection devices and 1 open entrapment protection device.
Expansion board - up to 3 entrapment protection devices configurable to either close or open and up to 4 edge sensors using wireless edge sensor kit model LMWEKITU.
MOUNTING FOOTPRINT
20-3/8" (51.75 cm)
15-3/16" (38.57 cm)
7.49" (19.02 cm)
13.65" (34.67 cm)
10-1/2" (26.67 cm)
7
INTRODUCTION
Site Preparation
Check the national and local building codes BEFORE installation.
Conduit and Concrete Pad
Trench and install conduit. Before trenching, contact underground utility locating companies. Conduit must be UL approved for low and high voltage. Consider the operator placement BEFORE installing the pad or post.
Safety
Entrapment protection devices are required to protect against any entrapment or safety conditions encountered in your gate application. Install a warning sign (two provided) on the inside and outside of the property, where easily visible.
Warning Sign
Concrete Pads
Gate
Gate must be constructed and installed according to ASTM F2200 standards (refer to page 4). Gate must fit specifications of operator
(refer to specifications).
Additional Accessories
The vehicle loops allow the gate to stay open when vehicles are obstructing the gate path. Suggested for vehicles 14 feet (4.27 m) or longer. Vehicle loops are not required but are recommended. Before installing your Access Control
Device(s) be sure to complete a site survey and determine the best device for your site needs.
Access Control
Device
Vehicle Loops
Outside Property
SAFETY CATCH ROLLERS
Install catch rollers with safety covers on the side of a post or wall with a minimal distance of half an inch between the rollers and gate
DO NOT use a gate catch post.
Because the coasting distance may vary due to changes in temperature, it is NOT recommended to install a catch post in front of the gate's path.
To do so will cause the gate to hit the post in certain instances.
8
INSTALLATION
• To AVOID damaging gas, power or other underground utility lines, contact underground utility locating companies BEFORE digging more than 18 inches (46 cm) deep.
• ALWAYS wear protective gloves and eye protection when changing the battery or working around the battery compartment.
Types of Installations
Standard Installation
Operator
Rear Installation
Gate Rail Stop
(Inside Property)
Operator
Gate Rail Stop
(Inside Property)
Gate Rail Stop Gate Rail Stop
9
INSTALLATION
Step 1 Determine Location for Operator
Check the national and local building codes before installation.
Standard Installation
1. The gate operator should be installed near the front roller of the gate. Lay out the concrete pad.
2. Install the electrical conduit.
3. Pour a concrete pad (reinforced concrete is recommended).
Gate
1" - 2" (2.5 - 5.1 cm)
1/2" (1.8 cm)
Front Gate Roller
Conduit
Location
Conduit
24" (61 cm)
(Pad)
Rear Installation
1. The gate operator should be installed near the back of the gate in the OPEN position. Lay out the concrete pad.
2. Install the electrical conduit.
3. Pour a concrete pad (reinforced concrete is recommended).
Gate in Open Position
1" - 2" (2.5 - 5.1 cm)
Back of Gate
1/2" (1.8 cm)
Conduit
Location
24" (61 cm)
(Pad)
Conduit
6" Above Ground
Below the frost line. Check all national and local codes.
6" Above Ground
Below the frost line. Check all national and local codes.
10
INSTALLATION
Step 2 Install the Operator
Attach the operator to the concrete pad with appropriate fasteners. The gate operator should be installed near the front roller of the gate or near the back of the gate (in the OPEN position). The space between the gate and the output sprocket must be a minimum of 4 inches (10.2 cm).
Mounting Footprint
.63"
(1.6 cm)
4 Concrete Anchors
1/2" x 3 1/2
(1.27 cm x 8.89 cm )
7.49"
(19 cm)
13.65" (34 cm)
4" (10 cm)
Chain Location
Operator
11
INSTALLATION
Step 3 Attach the Chain
Standard Installation
DO NOT run the operator until instructed.
1. Manually open the gate and line up the front bracket so the chain will be level with the idler pulley and parallel to the ground. Weld the front bracket in this position.
2. Manually close the gate and line up the rear bracket so the chain will be level with the idler pulley and parallel to the ground. Weld the rear bracket in this position.
3. Route the chain through the operator.
4. Connect the chain to the brackets using the eye bolt hardware. Chain should not be too tight or have excessive slack.
NOTE: The chain should have no more than 1 inch (2.5 cm) of sag for every 10 feet (3 m) of chain length.
Idler Pulley
Rear Bracket
Rear Installation
DO NOT run the operator until instructed.
NOTE: This installation will require two extra idler pulleys. Make sure all exposed pinch points are guarded. Refer to Gate Construction
Information on page 5.
1. Move the back pulley to the bottom hole in the operator.
2. Manually close the gate and align the bottom bracket so the chain will be level with the bottom idler pulley and parallel to the ground.
Weld the bottom bracket in this position.
3. Align the top bracket so the chain will be level with the top idler pulley and parallel to the ground. Weld the upper bracket in this position.
4. Route the chain through the operator.
5. Connect the chain to the brackets using the eye bolt hardware.
Chain should not be too tight or have excessive slack.
NOTE: The chain should have no more than 1 inch (2.5 cm) of sag for every 10 feet (3 m) of chain length.
12
Front Bracket
Idler Pulley MUST have safety cover.
INSTALLATION
To prevent SERIOUS INJURY or DEATH from a moving gate:
• ALL gate operator systems REQUIRE two independent entrapment protection systems for each entrapment zone.
• Entrapment protection devices MUST be installed to protect anyone who may come near a moving gate.
• Entrapment protection devices MUST be located to protect in BOTH the open and close gate cycles.
• Locate entrapment protection devices to protect between moving gate and RIGID objects, such as posts, walls, pillars, columns, or operator itself.
Step 4 Install Entrapment Protection
Entrapment protection MUST be installed according to the following UL
325 requirements:
• Slide gate operators require a minimum of two external monitored entrapment protection devices to function; one in the open direction and one in the close direction.
• Every installation is unique. It is the responsibility of the installer to ensure that ALL entrapment zones are protected with an external monitored entrapment protection device, protecting both the open and close gate cycles.
• LiftMaster monitored external entrapment protection devices
MUST be used with LiftMaster operators to meet UL325 requirements, see Accessories .
• Test ALL entrapment protection devices after completing installation of the operator. For testing instructions, refer to the manual provided with your entrapment protection device.
Definitions
ENTRAPMENT: The condition when a person is caught or held in a position that increases the risk of injury.
SLIDE GATE ENTRAPMENT ZONE: An entrapment zone exists if at any point during travel, the gap between the gate and any opposing fixed edge or surface such as posts, walls, pillars, columns or operator itself, is less than 16" (406 mm) in a location up to 6 ft. (1.8 m) above grade.
Illustrations provided by DASMA Gate Systems Safety Guide
Illustration is for example only; your site may have additional entrapment zones which MUST be protected.
Public Side
Pedestrian gate located near the slide gate.
Make sure a separate pedestrian entrance is available and the path is clearly designated.
6' (1.8 m) minimum
Place warning signs on both sides of the gate in clear view
Gap between vertical bars MUST be less than 2-1/4" (57 mm)
Interior posts, non-pinch rollers (2x)
Edge sensor
Edge sensor
Left hand gate opening
Earth ground
Photoelectric sensor (open direction)
Photoelectric sensor (open direction)
Edge sensor
Photoelectric sensor
(close direction)
Photoelectric sensor
(close direction)
Secure Side
Any gap larger than 2-1/4" (57 mm) between gate and fixed objects MUST be protected.
Install edge sensors where gap between post and gate creates a draw in zone.
Take a photograph of the complete installation site for your records
13
INSTALLATION
Wire Entrapment Protection Devices
There are three options for wiring external entrapment protection devices depending on the specific device and how the device will function. Refer to the manual included with your entrapment protection device for more information. These entrapment protection device inputs are for monitored devices, which include pulsed photoelectric sensors, resistive edge sensors, and pulsed edge sensors.
Only one monitored entrapment protection device may be wired to each input.
Additional entrapment protection devices may be wired to the expansion board.
Control Board
CLOSE EYES/INTERRUPT
(2 Terminals) The CLOSE EYES/INTERRUPT input is for photoelectric sensor entrapment protection for the close direction. When an obstruction is sensed during gate closing the gate will open to the full open position and resets the Timer-to-Close. This input will be disregarded during gate opening.
CLOSE EDGE
(2 Terminals) The CLOSE EDGE input is for edge sensor entrapment protection for the close direction. When an obstruction is sensed during gate closing the gate will reverse to the full open position, disengaging the Timer-to-Close. This input will be disregarded during gate opening.
OPEN EYES/EDGE
(2 Terminals) The OPEN EYES/EDGE input is for photoelectric sensor or edge sensor entrapment protection for the open direction. When an obstruction is sensed during gate opening the gate will reverse for 4 seconds then stop. This input will be disregarded during gate closing.
Close Photoelectric Sensors
Close Edge
Open Photoelectric Sensors OR Open Edge
Expansion Board (not provided)
EYE ONLY and COM
Open or Close Direction Photoelectric Sensors, the functionality is based on the switch settings (located next to the terminals)
Switch set to CLOSE: gate reverses fully when an obstruction is sensed
Switch set to OPEN: gate reverses 4 seconds when an obstruction is sensed
EYE/EDGE and COM
Open or Close Direction Photoelectric Sensors or Edge Sensor, the functionality is based on the switch settings (located next to the terminals)
Switch set to CLOSE: gate reverses fully when an obstruction is sensed
Switch set to OPEN: gate reverses 4 seconds when an obstruction is sensed
Photoelectric Sensors
Photoelectric
Sensors
OR
Edge
Sensor
14
INSTALLATION
Step 5 Earth Ground Rod
Use the proper earth ground rod for your local area. The ground wire must be a single, whole piece of wire. Never splice two wires for the ground wire. If you should cut the ground wire too short, break it, or destroy its integrity, replace it with a single wire length.
1. Install the earth ground rod within 3 feet (.9 m) of the operator.
2. Run wire from the earth ground rod to the operator.
NOTE: If the operator is not grounded properly the range of the remote controls will be reduced and the operator will be more susceptible to lightning and surge damage.
To operator
Check national and local codes for proper depth
Step 6 Power Wiring
To reduce the risk of SEVERE INJURY or DEATH:
• ANY maintenance to the operator or in the area near the operator
MUST NOT be performed until disconnecting the electrical power (AC or solar and battery) and locking-out the power via the operator power switch. Upon completion of maintenance the area MUST be cleared and secured, at that time the unit may be returned to service.
• Disconnect power at the fuse box BEFORE proceeding. Operator
MUST be properly grounded and connected in accordance with national and local electrical codes.
NOTE: The operator should be on a separate fused line of adequate capacity.
• ALL electrical connections MUST be made by a qualified individual.
• DO NOT install ANY wiring or attempt to run the operator without consulting the wiring diagram.
• ALL power wiring should be on a dedicated circuit and well protected.
The location of the power disconnect should be visible and clearly labeled.
• ALL power and control wiring MUST be run in separate conduit.
The operator can be wired for either 120 Vac or a solar panel (not provided). Follow the directions according to your application. The battery is charged in the circuit by the integrated transformer. The operator requires one 7AH battery (provided) or one 33AH battery. The 33AH application requires the 33AH wire harness (Model K94-37236).
For dual gate applications, power will have to be connected to each operator. Main power supply and control wiring MUST be run in separate conduits.
All control wiring used to connect external devices to Class 2 circuits of the operator must be (QPTZ) Power-Limited Circuit Cables, Type CL2, CL2P,
CL2R, or CL2X or other cable with equivalent or better electrical, mechanical, and flammability ratings.
SOLAR APPLICATIONS: For solar applications refer to Solar Panels section in the Appendix. Follow the directions according to your application.
15
INSTALLATION
Power wiring
1. Turn off the AC power from the main power source circuit breaker.
2. Run the AC power wires to the operator.
3. Unplug the transformer.
4. Remove the junction box cover.
5. Run the AC power wires through the knockout in the bottom of the electrical box.
6. Connect the green wire to the earth ground rod and AC ground using a wire nut.
NOTE: The earth ground rod can be grounded to the chassis.
7. Connect the white wire to NEUTRAL using a wire nut.
8. Connect the black wire to HOT using a wire nut.
9. Replace the junction box cover. Ensure the wires are not pinched.
10. Plug in the transformer.
11. Turn ON AC power to the operator.
AMERICAN WIRE
GAUGE (AWG)
18
16
14
12
10
MAXIMUM WIRE LENGTH
DIRECT PLUG-IN
TRANSFORMER (120
VAC)
EXTERNAL PLUG-IN
TRANSFORMER (24 VAC)
150 feet (46 m)
1150 feet (351 m)
1850 feet (564 m)
2950 feet (899 m)
NOTE: Use copper conductors ONLY.
250 feet (76 m)
400 feet (122 m)
600 feet (183 m)
1,000 feet (305 m)
Junction Box Cover
16
INSTALLATION
7AH battery
1. Unplug the transformer.
2. Unplug the J15 plug labeled BATT on the control board by squeezing the plug and pulling it from the control board. This disconnects the ac/dc power to the control board.
3. Connect the red wire from the J15 plug to the positive (+) terminal of the battery.
4. Connect the black wire from the J15 plug to the negative (-) terminal of the battery.
5. Plug the J15 plug back into the control board. This will power up the control board.
NOTE: You may see a small spark when plugging the
J15 plug into the board.
6. Plug in the transformer.
Red (+)
Solar Wires
Black(-)
J15 Plug
7AH Battery
33AH battery
To use a 33AH battery in place of the 7AH battery, follow the instructions below. The 33AH application requires the 33AH wire harness (Model K94-37236).
1. Unplug the transformer.
2. Unplug the J15 plug labeled BATT on the control board by squeezing the plug and pulling it from the control board. This disconnects the ac/dc power to the control board. Discard this J15 plug and harness.
3. Connect one end of the red (+) wire from the new 33AH wire harness kit to the red wire from the new J15 plug as shown.
Connect the other end of the red (+) wire to the positive (+) terminal on the battery as shown.
4. Connect one end of the black (-) wire from the new 33AH wire harness kit to the black wire from the new J15 plug as shown.
Connect the other end of the black (-) wire to the negative (-) terminal on the battery as shown.
5. Reconnect the new J15 plug to the control board.
NOTE: You may see a small spark when plugging the J15 plug into the board.
6. Plug in the transformer.
Red (+)
Red (+) wire from new wire harness kit
Solar Wires
Black(-)
J15 Plug
(New wire harness
Model
K94-37236)
Black(-) wire from new wire harness kit
33AH Battery
17
INSTALLATION
Step 7 Install the Cover
Before installing the cover, follow the instructions in the Adjustment section to adjust the limits and force.
1. Slide the cover over the operator.
2. Align the hole in the cover with the threaded hole in the operator's chassis and secure the cover with the provided 5/16-18 screw.
The basic installation is complete.
5/16"-18
(.79 cm)
Screw
18
ADJUSTMENT
Adjust the Limits and Automatic Force
To reduce the risk of SEVERE INJURY or DEATH:
• Without a properly installed safety reversal system, persons
(particularly small children) could be SERIOUSLY INJURED or
KILLED by a moving gate.
• Too much force on gate will interfere with proper operation of safety reversal system.
• NEVER increase force beyond minimum amount required to move gate.
• NEVER use force adjustments to compensate for a binding or sticking gate.
• If one control (force or travel limits) is adjusted, the other control may also need adjustment.
• After ANY adjustments are made, the safety reversal system MUST be tested. Gate MUST reverse on contact with an object.
Manual Adjustments
Your operator is designed with electronic controls to make travel limit and force adjustments easy. The adjustments allow you to program where the gate will stop in the open and close position. The limit setup
LEDs (located next to the SET OPEN and SET CLOSE buttons) indicate the status of the limits, refer to the table to the right.
The limits can be set using the control board (below) or a remote control
(refer to Limit Setup with a Remote Control in the Appendix). Setting the limits with a remote control requires a 3-button remote control programmed to OPEN, CLOSE, and STOP.
NOTE: While setting the limits, all entrapment protection devices will be disconnected, and the OPEN and CLOSE Test buttons can be used to move the gate as needed. During the Automatic Force Setup, all entrapment protection devices will be reconnected, and the gate will automatically open and close
NOTE: The TEST buttons on the control board will not work until the limits have been set and the required entrapment protection devices are installed.
SET OPEN
LED
OFF
BLINKING
BLINKING
ON
ON
SET CLOSE
LED
OFF
LIMIT SETUP LEDS
OPERATOR
MODE
NORMAL
MODE
BLINKING
ON
BLINKING
ON
MANUAL
SETUP
MANUAL
SETUP
MANUAL
SETUP
MANUAL
SETUP
EXPLANATION
Limits are set
Limits are not set
Open limit is not set
Close limit is not set
Limits are set
19
ADJUSTMENT
Enter Manual Setup Mode
NOTE: For dual gate applications, the limits will have to be set for each operator. The gate MUST be attached to the operator before setting the limits and force. Disconnect biparting gates before setting limits. Pay special attention if magnetic locks are installed.
NOTE: While setting the Limits, all entrapment protection devices will be disconnected, and the Remote Control buttons can be used to move the gate as needed. During the Automatic Force Setup, all entrapment protection devices will be reconnected, and the gate will automatically open and close.
For slide gate applications, the open limit and closed limit must be set up at least four feet apart.
1.
To enter manual set up mode, make sure that both SET OPEN and
SET CLOSE LEDs are flashing. If they are not flashing, press and release both the SET OPEN and SET CLOSE buttons.
Reversal Force Dial
2.
The REVERSAL FORCE DIAL is set to minimum at the factory. You will be able to adjust the force setting after the initial Manual Setup.
Once initial limits have been set, the REVERSAL FORCE dial on the
Control Board is used to fine tune the force where wind or environmental changes may affect the gate travel. See Fine Tune the
Force below.
All Settings 1-10: Automatically increase the force due to gate wear or temperature changes
Set the Limits
3.
Press and hold the MOVE GATE buttons to jog the gate to the desired OPEN position. Release the MOVE GATE button when the desired OPEN limit is reached.
4.
Press and release the SET OPEN button to save the limit.
5.
Press and hold the MOVE GATE buttons to jog the gate to the desired CLOSE position. Release the MOVE GATE button when the desired CLOSE limit is reached.
6.
Press and release the SET CLOSE button to save the limit.
7.
Upon successfully setting the limits for your gate setup, the Manual
Setup Mode will exit.
1 2
6
3
5
4
20
ADJUSTMENT
Automatic Force
Once manual setup mode has been exited, all entrapment protection devices will reconnect and become operational. The operator will enter a forcesensing operation by automatically moving the gate. The operator will begin a pre-warning audible alert before automatically moving the gate for a full cycle (open and close). During movement, the operator will continue with an audible alert. At successful completion of the automatic force setup, the audible alert turns off and the Diagnostic display will read ‘00’. The operator is now ready for normal operation.
If the automatic force setup does not complete successfully, the operator will reenter Manual Setup Mode. Return to Step 1 of Manual Adjustments.
NOTE: If the gate stops or reverses before reaching the fully open or closed position, increase the force by turning the force control slightly clockwise. See
Fine Tune the Force below.
Fine Tune the Limits
To adjust the limits, start at Step 1 of the Manual Adjustment section.
Fine Tune the Force
Based on the length and weight of the gate it may be necessary to make additional force adjustments. The force setting should be high enough that the gate will not reverse by itself nor cause nuisance interruptions, but low enough to prevent serious injury to a person. The force setting is the same for both the open and close gate directions.
Once the initial limits have been set, the REVERSAL FORCE DIAL on the control board is used for fine tuning the force where wind or environmental changes may affect the gate travel.
1.
Enter manual set up mode: press and release both the SET OPEN and SET CLOSE limit buttons. Both Limit LEDs will turn on solid (see Limit LED table above). The operator will beep once. This will cause all entrapment protection devices to be disconnected.
2.
Adjust the reversal force dial for the installation. The REVERSAL FORCE DIAL is set to minimum at the factory.
All Settings 1-10: Automatically increase the force due to gate wear or temperature changes.
3.
Exit setup mode by pressing and releasing both the SET OPEN and SET CLOSE buttons. Limit LEDs will turn off. All entrapment protection devices will reconnect and become operational.
4.
Perform the “Obstruction Test” after every limit and force setting adjustment.
Note: Automatic Force Setup will not run if only the force setting was changed
Obstruction Test
The operator is equipped with an inherent (built in to the operator) obstruction sensing device. If the gate encounters an obstruction during motion, the gate reverses all the way to the limit. The following procedure will test ONLY the inherent (built in to the operator) obstruction sensing device:
1.
Open and close the gate with the TEST BUTTONS, ensuring that the gate is stopping at the proper open and close limit positions.
2.
Place an object between the open gate and a rigid structure. Make sure that any external entrapment protection devices will NOT be activated by the object.
3.
Run the gate in the close direction. The gate should stop and reverse upon contact with the object. If the gate does not reverse off the object, reduce the force setting by turning the force control slightly counter-clockwise. The gate should have enough force to reach both the open and close limits, but MUST reverse after contact with an object.
4. Repeat the test for the open direction.
Test the operator after any adjustments are made.
21
1
1
2
3
DUAL GATE SETUP
Dual Gate Setup-Wired
There are two options for dual gate communication: wired or wireless. Follow the directions according to your application. Do not use wired and wireless communication simultaneously.
Wired dual gate applications will have a longer battery standby time than wireless applications.
Before digging, contact local underground utility locating companies. Use
PVC conduit to prevent damage to cables.
DUAL GATE WIRE TYPE (SHIELDED TWISTED PAIR CABLE)
1. Disconnect ALL power to the operator and unplug the J15 plug from the control board.
22AWG up to 200 feet (61 m) 18AWG - 200-1000 feet (61-305 m)
Wire must be rated at 30 Volt minimum
2. Trench across driveway to bury the shielded twisted pair cable.
3. Connect the wires from the shielded twisted pair cable to the Com Link terminals on the primary gate operator control board.
NOTE: We recommend that all accessories and board configurations are set on the primary operator.
4. Route the shielded twisted pair cable to the secondary gate operator's control board.
5. Connect the wires from the shielded twisted pair cable to the Com Link terminals on the secondary control board (Com Link A to Com Link A and Com Link B to Com Link B). Ground the shield of the cable to the chassis ground of one operator.
6. Connect ALL power to the operator and plug the J15 plug into the control board.
Com Link Data A
Com Link Data B
Com Link Data A
Com Link Data B
Dual Gate Setup-Wireless
To activate the wireless feature:
1. Choose an operator to be the network primary operator. All wireless accessories will need to be programmed to the primary operator.
NOTE: We recommend that all accessories and board configurations are set on the primary operator.
2. Press and release the LEARN button on the primary operator. The green XMITTER LED will light.
NOTE: The operator will time out of programming mode after 180 seconds.
3. Press and release the LEARN button again on the primary operator. The yellow NETWORK LED will light.
4. Press and release the OPEN test button to assign this operator as network primary.
5. Press and release the LEARN button on the second operator. The green XMITTER LED will light.
6. Press and release the LEARN button again on the second operator. The yellow NETWORK LED will light.
7. Press and release the CLOSE test button to assign this operator as network second.
Both operators will beep and the yellow NETWORK LEDs will turn off indicating programming is successful.
To deactivate the wireless feature (Erasing the wireless feature will also erase any learned transmitters and keypads):
1. Press and release the LEARN button on either operator. The green XMITTER LED will light.
2. Press and release the LEARN button again on the same operator. The yellow NETWORK LED will light.
3. Press and hold the LEARN button for 5 seconds. The yellow NETWORK LED will blink (operator will beep) then turn off indicating successful deactivation.
4. Repeat the steps for the other operator.
22
DUAL GATE SETUP
Pro per ty e
Pr op erty
Bipart delay/synchronized close
The LOCK/BIPART DELAY switch is used only with dual gate applications and serves two functions:
• BIPART DELAY
SWING GATE APPLICATIONS: The BIPART DELAY is used in applications where a mag-lock, solenoid lock, or decorative overlay would require one gate to close before the other. The operator with the LOCK/BIPART DELAY switch ON will delay from the close limit when opening and be the first to close from the open limit.
SLIDE GATE APPLICATIONS: Not applicable, set to OFF.
• SYNCHRONIZED CLOSE
The BIPART DELAY is also used in applications where one gate travels a longer distance than the other. To synchronize the closing of the gates, set the LOCK/BIPART DELAY switch to ON for both operators.
23
PROGRAMMING
Remote Controls (Not Provided)
A total of 50 Security+ 2.0
® remote controls or KPW250 keypads and 2 keyless entries (1 PIN for each keyless entry) can be programmed to the operator. When programming a third keyless entry to the operator, the first keyless entry will be erased to allow the third keyless entry to be programmed. When the operator’s memory is full it will exit the programming mode and the remote control will not be programmed. The memory will need to be erased before programming any additional remote controls.
NOTE: If installing an 86LM to extend the range of the remote controls DO NOT straighten the antenna.
The operator can learn remote controls on a single frequency of either
315 MHz, 390.0 MHz, or 433.92 MHz (where available). The default frequency will be 315 MHz. This can be changed prior to learning remote controls. Any remote controls learned will need to be erased before the frequency can be changed.
Change Frequency
1. Press and release the LEARN button (operator will beep and green
XMITTER LED will light). NOTE: The display will show what frequency is currently selected.
2.
Use the MOVE GATE buttons to select the desired frequency.
F1 = 315 MHZ (default)
F2 = 390 MHz
F3 = 433.92 MHz (where available)
3. Follow the steps below to learn a remote control to lock in the selected frequency.
There are 3 different options for programming the remote control depending on how you would like the remote control to function. Choose a programming option:
OPTION
Single button as OPEN only
Single button (SBC) as
OPEN, CLOSE, and STOP
DESCRIPTION
Program a single button on the remote control for open only. The Timer-to-Close can be set to close the gate.
Program one remote control button as an open, close, and stop.
PROGRAMMING STEPS
1. Press and release the LEARN button (operator will beep and green
XMITTER LED will light).
NOTE: The operator will time out of programming mode after 30 seconds.
2. Press the OPEN button.
3. Press the remote control button that you would like to program.
1. Press and release the LEARN button (operator will beep and green
XMITTER LED will light).
NOTE: The operator will time out of programming mode after 30 seconds.
2. Press the remote control button that you would like to program.
Three separate buttons as
OPEN, CLOSE, and STOP
Program each remote control button as an open, close, and stop.
1. Press and release the LEARN button (operator will beep and green
XMITTER LED will light).
NOTE: The operator will time out of programming mode after 30 seconds.
2. Press the OPEN, CLOSE, or STOP button, depending on the desired function.
3. Press the remote control button that you would like to program.
24
PROGRAMMING
The operator will automatically exit learn mode (operator will beep and green XMITTER LED will go out) if programming is successful. To program additional Security+ 2.0
® remote controls or remote control buttons, repeat the programming steps above.
NOTICE: This device complies with Part 15 of the FCC rules and Industry Canada’s license-exempt RSSs. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device must be installed to ensure a minimum 20 cm (8 in.) distance is maintained between users/bystanders and device.
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules and Industry Canada ICES standard. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
25
PROGRAMMING
LiftMaster Internet Gateway (not provided)
To program the operator to the LiftMaster Internet Gateway:
Using the learn button on the operator's control board
1.
Connect the Ethernet cable to the LiftMaster Internet Gateway and the router.
2.
Connect power to the LiftMaster Internet Gateway.
3.
Create an online account by visiting www.myliftmaster.com.
4.
Register the LiftMaster Internet Gateway.
5.
Use an internet enabled computer or smartphone to add devices. The
LiftMaster Internet Gateway will stay in learn mode for three minutes.
6.
Press the Learn button twice on the primary operator (the operator will beep as it enters learn mode). The LiftMaster Internet Gateway will pair to the operator if it is within range and the operator will beep if programming is successful.
Using the reset button on the operator
1.
Connect the ethernet cable to the LiftMaster Internet Gateway and the router.
2.
Connect power to the LiftMaster Internet Gateway.
3.
Create an online account by visiting www.myliftmaster.com.
4.
Register the LiftMaster Internet Gateway.
5.
Use an internet enabled computer or smartphone to add devices. The
LiftMaster Internet Gateway will stay in learn mode for three minutes.
6.
Ensure gate is closed.
7.
Give the operator an OPEN command.
8.
Within 30 seconds, when the gate is at the open limit press and release the reset button 3 times (on primary gate) to put primary operator into
High Band Learn Mode (the operator will beep as it enters learn mode). The LiftMaster Internet Gateway will pair to the operator if it is within range and the operator will beep if programming is successful.
The status as shown by the LiftMaster Internet Gateway app will be either
“open” or “closed”. The gate operator can then be controlled through the
LiftMaster Internet Gateway app.
Erase Gateway
Note: Doing this will erase all wireless learned devices including transmitters, keypads and any wireless dual gate programming.
1.
Press and release the LEARN button on either operator. The green
XMITTER LED will light.
2.
Press and release the LEARN button again on the same operator. The yellow NETWORK LED will light.
3.
Press and hold the LEARN button for 5 seconds. The yellow
NETWORK LED will blink (operator will beep) then turn off indicating devices have been successfully erased.
Erase All Transmitter and Keypad Codes
1. Press and release the LEARN button (operator will beep and green
XMITTER LED will light).
2. Press and hold the LEARN button again until the green XMITTER LED flashes and then release the button (approximately 6 seconds). All remote control codes are now erased.
Erase Limits
1. To erase the limits, press and hold the SET OPEN and SET CLOSE buttons simultaneously (5 seconds) until both the SET OPEN and SET
CLOSE LEDs blink rapidly and the operator beeps.
2. Release the buttons and the SET OPEN and SET CLOSE LEDs will blink slowly indicating the limits will need to be set.
Constant Pressure Override (CPO)
Constant Pressure Override is for use with KPW5 and KPW250 keypads
(not provided). The KPW5/KPW250 wireless commercial keypads are security keypads and can only be programmed to ONE gate operator (see the KPW5/KPW250 manual for complete programming instructions).
The Constant Pressure Override feature is intended to temporarily override a fault in the entrapment protection system, in order to operate the gate until the external entrapment protection device is realigned or repaired. Use the feature only in line of sight of the gate when no obstructions to travel are present. External entrapment protection devices include LiftMaster monitored photoelectric sensors and LiftMaster monitored wired and wireless edge sensors. Be sure to repair or replace these devices promptly if they are not working properly.
To use Constant Pressure Override:
1. Enter a valid 4-digit PIN.
2. Press and hold # for 5 seconds to enter CPO. Continue to hold # to keep the operator in motion. A continuous tone will sound until limit is met and/or # is released.
3. The operator will stop when either the operator reaches a limit or the user releases #.
Gate Hold Open Feature
The gate hold open feature will disable the timer and keep the gate at the open limit. The gate hold open feature can be activated through the Reset
Button as described on Page 29 or through the KPW5 and KPW250 keypads (not provided).
To use the gate hold open feature:
1. Enter a valid 4-digit PIN when the gate is at the Open Limit and the timer is running
2. The Operator will chirp indicating the timer is canceled.
To restart the gate:
1. Re-enter the 4-digit PIN
2. Activate a Hard input or a programmed remote
To Remove and Erase Monitored Entrapment
Protection Devices
1. Remove the entrapment protection device wires from the terminal block.
2. Press and release the SET OPEN and SET CLOSE buttons simultaneously. The SET OPEN and SET CLOSE LEDs will turn on
(entering learn limit mode).
3. Press and release both SET OPEN and SET CLOSE buttons again to turn off the SET OPEN and SET CLOSE LEDs (exiting learn limit mode).
26
OPERATION
Control Board Overview
1 SET OPEN Button: The SET OPEN button sets the OPEN limit. See Adjustment section.
2 SET CLOSE Button: The SET CLOSE button sets the CLOSE limit. See Adjustment section.
3 MOVE GATE Buttons: The MOVE GATE buttons will either open or close the gate when the operator is in Manual Setup mode. See Adjustment section.
4 BATT FAIL:
• When AC power is OFF and battery voltage is critically low the gate will latch at a limit until AC power is restored or batteries voltage increases.
• Option select switch set to OPEN forces gate to automatically open and then latch at the OPEN limit until AC power is restored or battery voltage increases.
• Option select switch set to CLOSE forces gate to latch at CLOSE limit if at CLOSE limit or on next CLOSE command until AC power restored or battery voltage increases.
• Constant pressure on a hard command input overrides to open or close the gate.
• Critically low battery is less than 11.5 V
5 BIPART DELAY Switch: The LOCK/BIPART DELAY switch is used only for dual gates. See Bipart Delay section.
6 LEARN Button: The LEARN button is for programming remote controls and the network.
7 TIMER-TO-CLOSE dial: The TIMER-TO-CLOSE (TTC) dial can be set to automatically close the gate after a specified time period. The TTC is factory set to OFF. If the TTC is set to the OFF position, then the gate will remain open until the operator receives another command from a control. Rotate the TIMER-
TO-CLOSE dial to the desired setting. The range is 0 to 180 seconds, 0 seconds is OFF.
NOTE: Any radio command, single button control, or CLOSE command on the control board prior to the TTC expiring will close the gate. The TTC is reset by any signals from the open controls, loops, close edges, and close photoelectric sensors (IR’s).
8 REVERSAL FORCE dial: The REVERSAL FORCE dial fine tunes the force. See Adjustment section.
9 TEST BUTTONS: The TEST BUTTONS will operate the gate (OPEN, STOP and CLOSE).
10 STATUS LEDs: The STATUS LEDs indicate the status of the operator. See Status LED Chart in the Troubleshooting section.
11 DIAGNOSTICS Display: The diagnostics display will show the operator type, firmware version, and codes. The operator type will display as "SL" followed by a "12" which indicates the operator type as RSL12UL. The firmware version will show after the operator type, example "1.2".
12 BACKDRIVE Switch: Set to MANUAL will allow the gate to be manually pushed open or closed if there is a loss of AC and battery power. Set to
SECURE makes the gate difficult to push open or closed if there is a loss of AC and battery power.
1 2 4 5 6 9
3
11
10
7 8
27
12
OPERATION
Reset Switch
The reset switch is located on the front of the operator and serves several functions.
Toggling the reset switch will stop a moving gate during a normal open/ close cycle, like a stop button. The operator does not need to be reset after doing this. The reset switch will disable the gate in the present position and will energize the solenoid lock for two minutes and disable the maglock for two minutes.
Reset/Disconnect
Reset/Disconnect
Manual Disconnect
Press the reset switch to RESET/DISCONNECT. Release the handle on the operator arm to allow the gate to be opened and closed manually. On a dual gate application the handle must be released on both operators. To resume normal function tighten the handle by pushing it down.
Operator Alarm
If a contact sensor detects an obstruction twice consecutively the alarm will sound (up to 5 minutes) and the operator will need to be reset. When the inherent force of the operator detects the following twice consecutively, the alarm will sound up to 5 minutes and the operator will need to be reset.
A. The gate is hitting an obstruction.
B. The gate does not meet specifications.
C. Debris is on the gate's track such as mud, rocks, dirt, etc.
D. The gate has one or more broken axles or wheels.
E. The gate wheel is off the gate rail.
Remove any obstructions. Press the reset button to shut off the alarm and reset the operator. After the operator is reset, normal functions will resume.
The operator alarm will beep 3 times with a command if the battery is low.
A
C
E
B
D
Remote control
Single Button Control (SBC) Functionality
Once the remote control has been programmed the operator will operate as follows:
When gate is in the closed position, activation of the remote control button will open the gate. During the open cycle another activation of the remote control will stop the gate and the next activation of the remote control will close the gate.
When the gate is in the open position, activation of the remote control button will close the gate. If the remote control is activated while the gate is closing, the gate will stop and the next activation will open the gate.
28
ACCESSORY WIRING
All control wiring used to connect external devices to Class 2 circuits of the operator must be (QPTZ) Power-Limited Circuit Cables, Type CL2, CL2P,
CL2R, or CL2X or other cable with equivalent or better electrical, mechanical, and flammability ratings.
External Control Devices
NOT TO BE USED AS ENTRAPMENT PROTECTION
EXIT (2 Terminals)
This input is a soft open command (maintained switch does not override external safeties and does not reset alarm condition). Used for exit probe, telephone entry, external exit loop detector, or any device that would command the gate to open.
• Opens a closed or closing gate and holds open an open gate, if maintained, pauses Timer-to-Close at OPEN limit.
SHADOW (2 Terminals)
This input is used for external shadow loop detector when loop is positioned under the swing of the gate.
• Holds open gate at open limit
• Only active when the gate is at the OPEN limit, disregarded at all other times
• Pauses Timer-to-Close at OPEN limit
INTERRUPT (2 Terminals)
This input is used for an external interrupt loop detector when loop is on the outside of the gate.
• Holds open gate at open limit
• Stops and reverses a closing gate to open limit
• Pauses Timer-to-Close at OPEN limit, activates quick close and antitailgate features when enabled on the expansion board
Access control device wiring
Loop wiring
Exit
Com
Control board
Control board
Exit
Com
Shadow
Com
Interrupt
Com
Access Control Device
Interrupt Loop
Exit Loop
29
ACCESSORY WIRING
Locks
Maglock (2 Terminals, N.C. and COM)
Relay contact output, Normally - closed (N.C.) output for maglocks.
Relay activates prior to motor activation and during motor run. Relay is off when motor is off.
CONTROL BOARD
Miscellaneous wiring
Three button control station (4 Terminals)
• OPEN and COM: Opens a closed gate. Hard open (maintained switch overrides external safeties and resets alarm condition). If maintained, pauses Timer-to-Close at OPEN limit. Opens a closing gate and holds open an open gate (within line-of-sight).
• CLOSE and COM: Closes an open gate. Hard close (maintained switch overrides external safeties and resets alarm condition within line-of-sight)
• STOP and COM: Stops a moving gate. Hard stop (maintained switch overrides Open and Close commands and resets alarm condition). If maintained, pauses Timer-to-Close at OPEN limit. Overrides Open and Close commands (within line-of-sight).
Fire department input (2 Terminals)
Acts as hard open.
Maintained input overrides (ignores) external safeties (photoelectric sensor and edge), pauses Timer-to-Close momentary input logic as single button control and safeties remain active, re-enables Timer-to-Close.
Accessory power 12 VDC, max 500 mA (4 Terminals)
• SWITCHED: Switched ON with gate motion and at the open limit when
Timer-to-Close is active. Turns off 5 seconds after motion.
• UNSWITCHED: 12 Vdc voltage out to power accessories, always ON.
MAGLOCK
NOT
PROVIDED
MAIN CONTROL BOARD
Three Button Control Station
Open
Close
Stop
N.C.
Com
Fire Dept
Com
Fire Department
MAIN CONTROL BOARD
Accessory Power Switched
Com (-)
Acc power +12 Vdc
Com (-)
Acc power +12 Vdc
Accessory Power Unswitched
30
MAINTENANCE
IMPORTANT SAFETY INSTRUCTIONS
To reduce the risk of SEVERE INJURY or DEATH:
• READ AND FOLLOW ALL INSTRUCTIONS.
• ANY maintenance to the operator or in the area near the operator
MUST NOT be performed until disconnecting the electrical power
(AC or solar and battery) and locking-out the power via the operator power switch. Upon completion of maintenance the area MUST be cleared and secured, at that time the unit may be returned to service.
• Disconnect power at the fuse box BEFORE proceeding. Operator
MUST be properly grounded and connected in accordance with national and local electrical codes.
NOTE: The operator should be on a separate fused line of adequate capacity.
• NEVER let children operate or play with gate controls. Keep the remote control away from children.
• ALWAYS keep people and objects away from the gate. NO ONE
SHOULD CROSS THE PATH OF THE MOVING GATE.
• The entrance is for vehicles ONLY. Pedestrians MUST use separate entrance.
• TEST THE GATE OPERATOR MONTHLY.
The gate MUST reverse on contact with an object or reverse when an object activates the noncontact sensors. After adjusting the force or the limit of travel, retest the gate operator. Failure to adjust and retest the gate operator properly can increase the risk of INJURY or DEATH.
• Use the manual disconnect release ONLY when the gate is NOT moving.
• KEEP GATES PROPERLY MAINTAINED. Read the owner’s manual.
Have a qualified service person make repairs to gate hardware.
• ALL maintenance MUST be performed by a Trained Gate Systems
Technician.
• Activate gate ONLY when it can be seen clearly, is properly adjusted and there are no obstructions to gate travel.
•
• To reduce the risk of FIRE or INJURY to persons use ONLY
LiftMaster part 29-NP712 for replacement batteries.
SAVE THESE INSTRUCTIONS.
• ALWAYS wear protective gloves and eye protection when changing the battery or working around the battery compartment.
Maintenance Chart
Disconnect all power (AC, solar, battery) to the operator before servicing.
The operator's AC Power switch ONLY turns off AC power to the control board and DOES NOT turn off battery power. ALWAYS disconnect the batteries to service the operator.
DESCRIPTION TASK CHECK AT LEAST ONCE EVERY
MONTH 6 MONTHS 3 YEARS
X Entrapment Protection Devices Check and test inherent (built into the operator) and external devices for proper operation
Warning Signs
Manual Disconnect
Make sure they are present and replace if worn or broken, see
Check and test for proper operation
Accessories
Drive Chain and Sprockets
Belt and Pulley
Gate
Check for excessive slack and lubricate
Check for excessive slack, wear or damage
Inspect for wear or damage; ensure it still complies with ASTM F2200, see
Accessories
Electrical
Chassis Mounting Bolts
Operator
Batteries
Check all for proper operation
Inspect all wire connections
Check for tightness
Inspect for wear or damage
Replace
X
X
X
X
X
X
X
X
X
X
NOTES:
• Severe or high cycle usage will require more frequent maintenance checks.
• Limits may have to be reset after any major drive chain adjustments.
• If lubricating chain, use only lithium spray. Never use grease or silicone spray.
• It is suggested that while at the site voltage readings be taken at the operator. Using a digital voltmeter, verify that the incoming voltage to the operator is within ten percent of the operator’s rating.
31
MAINTENANCE
Batteries
Batteries will degrade over time depending on temperature and usage. The operator alarm will beep 3 times with a command if the battery is low. Batteries do not perform well in extremely cold temperatures. For best performance, the batteries should be replaced every 3 years. Use only LiftMaster part
29-NP712 for replacement batteries. The batteries contain lead and need to be disposed of properly.
The operator comes with one 7AH battery. One 33AH Battery (A12330SGLPK), with 33AH Battery Harness (K94-37236) may be used in place of the 7AH battery.
Drive Train
Over time, the drive chain on the operator will stretch and need to be tightened. To tighten the drive chain adjust either of the two chain eye bolts.
NOTE: The chain should have no more than 1 inch of sag for every 10 feet of chain length.
32
TROUBLESHOOTING
To protect against fire and electrocution:
• DISCONNECT power (AC or solar and battery) BEFORE installing or servicing operator.
For continued protection against fire:
• Replace ONLY with fuse of same type and rating.
Diagnostic Codes
NOTE: When cycling or disconnecting power (ac/dc) to the control board, it is recommended that you unplug the J15 plug.
DIAGNOSTICS DISPLAY OPEN, CLOSE, & STOP BUTTONS
To View the Codes
The codes will show on the diagnostic display.
...then press and hold the
CLOSE button...
...then press and hold the
OPEN button until "Er" shows on the display.
Press and hold the
STOP button...
The operator will show the code sequence number followed by the code number:
CODE SEQUENCE NUMBER
The first number shown is the most recent code (example:
"01"). The display will show the sequence of codes that occurred starting with "01" and going up to code "20".
A SECOND
LATER....
CODE NUMBER
The second number shown after the code sequence number is the code itself (31-99, example"
"31"). Refer to the chart on the following page for an explanation of each code.
DIAGNOSTICS
To Scroll Through the Saved Codes
Press the OPEN button to cycle to the most recent code ("01").
Press the CLOSE button to cycle to the oldest code (up to "20").
The operator will only keep track of up to 20 codes, then will start saving over the oldest codes as new codes occur.
To Exit
Press and release the STOP button to exit. The display will also time out after two minutes of inactivity.
To Reset the Code History
1. Press and hold the STOP button for six seconds. The display will show
"Er" then "CL" alternately for six seconds.
2. Release the STOP button. The code history has now been reset and the display will show "- -" until a new code occurs.
3. Press and release the STOP button to exit.
33
TROUBLESHOOTING
Diagnostic Codes Table
Some codes are saved in the code history and some are not. If a code is not saved it will briefly appear on the display as it occurs, then disappear.
LiftMaster System Installed System Informational
External Entrapment
Protection
Inherent Entrapment
Protection
Code Meaning
00
Normal Operation
31
34
35
36
53
54
60
61
62
63
64
40
41
42
43
44
45
46
50
37
38
3A
Main control board has experienced an internal failure.
Absolute Position Encoder Error, not getting position information from encoder
Max-Run-Time Exceeded Error
Product ID Error
Product ID Failure
Hard Stop Limit (Arm 1)
Invalid Force Setting Change
Battery overvoltage
Battery overcurrent
No battery at boot up
Exit Loop Error
Shadow Loop Error
Interrupt Loop Error
Wireless edge battery low
Run-Distance Error
Brownout occurred
Wireless Second Operator Communication Error
Minimum number of monitored entrapment protection devices not installed.
CLOSE EYE/INTERRUPT held more than 3 minutes
CLOSE EDGE held more than 3 minutes
OPEN EYE/EDGE held more than 3 minutes
CLOSE EYE/INTERRUPT held more than 3 minutes
Solution
No Action Required
Disconnect all power, wait 15 seconds, then reconnect power (reboot). If issue continues, replace main control board.
Check APE assembly and wiring connections. Replace the APE assembly if necessary.
Check for an obstruction, then reprogram the limits.
Was the control board just replaced? If so, erase limits, enter limit setup mode and set limits. If not, disconnect all power, wait 15 seconds, then reconnect power before changing product ID harness.
Unplug product ID harness then plug back in. Disconnect all power, wait
15 seconds, then reconnect power before replacing product ID harness.
Limit may be set too tightly against a non-resilient hard stop (re-adjust limit). Operator may be at end of travel (re-adjust mounting).
Reversal Force Dial Setting was changed outside of Manual Setup Mode.
Return the dial to the previous setting to clear the code or enter and exit
Manual Setup Mode for the change to take effect.
Too much voltage on the battery. Check harness. Make sure there is NOT a 24V battery on a 12V system.
Possible short of the battery charge harness. Check harness. Make sure you do NOT have a 12V battery on a 24V system.
Check battery connections and installation. Replace batteries if depleted to less than 20V on a 24V system or less than 10V on a 12V system.
Make sure there is NOT a single 12V battery on a 24V system.
Failure or missing loop (SHORT or OPEN - LiftMaster Plug-in Loop
Detector only) Check loop wiring throughout connection. May be a short in the loop, or an open connection in the loop.
Replace batteries in wireless edge.
The limits are less than the minimum requirement or longer than what was learned. Check limit positions and proper switch function. Rundistance can be re-learned by setting the handing again.
AC/DC board supply dipped below allowable level. Review power supply and wiring. If rebooting, ensure enough time for discharge of power to force a fresh boot.
Check the second operator for power. If OFF, restore power and try to run the system. If powered, deactivate the wireless feature and then re-learn the second operator.
Review monitored entrapment protection device connections. Slide gate operators require a minimum of two external safety devices; one in the close and one in the open direction.
Saved
NO
NO
YES
YES
YES
YES
NO
NO
YES
YES
YES
YES
YES
YES
YES
YES
NO
Check wired input on main control board; check for alignment or obstruction.
Check wired input on expansion board; check for alignment or obstruction.
34
YES
YES
TROUBLESHOOTING
Code Meaning
65 CLOSE EYE/EDGE held more than 3 minutes
66
67
68
OPEN EYE/EDGE held more than 3 minutes
Wireless edge triggered more than 3 minutes
Wireless edge loss of monitoring
69 Wireless edge triggered
70
71
72
73
74
75
80
81
82
83
84
91
93
99
CLOSE EYE/INTERRUPT triggered, causing reversal, preventing close, or resetting TTC
CLOSE EDGE triggered, causing reversal, NO preventing close, or canceling TTC
OPEN EYE/EDGE triggered, causing reversal or preventing opening
CLOSE EYE/INTERRUPT triggered, causing reversal, preventing close, or resetting TTC
CLOSE EYE/EDGE triggered, causing reversal and preventing close or canceling TTC
OPEN EYE/EDGE triggered, causing reversal or preventing opening
Close input (EYE/EDGE) communication fault from other operator
Open input (EYE/EDGE) communication fault from other operator
Close input (EYE/EDGE) communication fault
(expansion board)
Open input (EYE/EDGE) communication fault
(expansion board)
Non-monitored device detected on the wireless safety system
Force Reversal (Operator 1)
RPM / STALL Reversal (Operator 1)
Normal Operation
Solution
Check wired input for wiring issue or obstruction.
Check wireless edge inputs.
IF an obstruction occurred, no action required. If an obstruction did NOT occur, check inputs and wiring.
IF an obstruction occurred, no action required. If an obstruction did NOT occur, check alignment, inputs, and wiring on main control board
IF an obstruction occurred, no action required. If an obstruction did NOT occur, check alignment, inputs, and wiring on expansion board.
Check inputs and communication method between operators, either wired bus or radio. Ensure operator is powered. May have to erase the wireless communication and reprogram the two operators.
Check the connections between the main board and the expansion board.
Non-monitored contact closure devices are not supported. Make sure connected devices are monitored. Check edges for proper orientation and resistive end cap connection.
Check for obstruction. If no obstruction, check that the mechanical assembly is engaged and free to move. See section on Limit and Force
Adjustment, and Obstruction Test.
Check for obstruction. If no obstruction, check the operator wiring and that the mechanical assembly is engaged and free to move. Replace APE assembly.
No action required
Saved
YES
YES
NO
NO
NO
YES
YES
YES
YES
YES
YES
35
TROUBLESHOOTING
Control Board LEDs
INPUT
POWER
BATT
CHARGING
TIMER
GATE
MOVING
ACC PWR
OVLD
OFF
ON
OFF
ON
OFF
ON
MEDIUM BLINK (1 blink per second)
STATUS LEDS
OFF state
AC charger or Solar power available
Not charging
Three stage battery charging
The timer is disabled
The timer is enabled
The timer is running
FAST BLINK (2 blinks per second)
FASTEST BLINK (8 blinks per second)
OFF
ON
The timer is paused
The timer is canceled
MEDIUM BLINK (1 blink per second)
FASTEST BLINK (8 blinks per second)
BATT LOW OFF
ON
MEDIUM BLINK (1 blink per second)
OFF
ON
The gate is stopped
The gate is opening or closing
Operator is in E1 (single entrapment)
The operator is in E2 (double entrapment)
No battery error
Battery low
Battery critically low
Accessory power is okay
Accessory overload protector opened
STATUS LEDS
OPEN, CLOSE,
STOP INPUT
FIRE DEPT INPUT
EXIT
SHADOW
CLOSE
EYES/INTERRUPT
CLOSE EDGE
OPEN EYES/EDGE
LOCK
INPUT LEDS
OFF
ON
BLINK
OFF
ON
BLINK
OFF
ON
ON
BLINK
OFF
ON
BLINK
OFF
ON
BLINK
OFF
INPUT LEDS
Input inactive
ON
BLINK
Input active
Input active on other operator or expansion board
OFF
ON
BLINK
OFF
Input inactive
Input active
Input active on other operator
Input inactive
Input active
Input active on other operator
Input inactive
Input active
Input active on other operator
Input inactive
Input active
Input active on other operator
Input inactive
Input active
Input active on other operator
Input inactive
Input active
Input active on other operator
Maglock relay inactive
Maglock relay active
36
TROUBLESHOOTING
Troubleshooting Chart
SYMPTOM
Operator does not run and diagnostic display not on.
Control board powers up, but motor does not run.
Gate moves, but cannot set correct limits.
Gate does not fully open or fully close when setting limits.
Operator does not respond to a wired control/command
(example: Open,
Close, SBC, etc.)
Operator does not respond to a wireless control or transmitter
Gate stops during travel and reverses immediately.
Gate opens, but will not close with transmitter or
Timer-to-Close.
POSSIBLE CAUSES a. No power to control board b. Open fuse c. If on battery power only, low or dead batteries d. Defective control board a. Reset switch is stuck b. Stop button active or jumper not in place for stop circuit c. If on battery power only, low or dead batteries d. Open or Close input active e. Entrapment Protection Device active f. Vehicle loop detector or probe active g. Defective control board a. Gate does not move to a limit position b. Gate is too difficult to move c. Limits are set too close (slide gate applications only) a. Gate does not move to a limit position b. Gate is too difficult to move a. Check Open and Close command input LEDs b. Stop button is active c. Reset button is stuck d. If on battery power only, low or dead batteries e. Entrapment Protection Device active f. Vehicle loop detector or vehicle probe active a. Check XMITTER LED when wireless control is active b. Stop button is active c. Reset button is stuck d. Poor radio reception a. Control (Open, Close) becoming active b. Vehicle loop detector active c. Low battery voltage a. Open control active b. Vehicle loop detector active c. Loss of AC power with AC FAIL set to OPEN d. Low battery with LOW BATT set to OPEN e. Fire Dept input active f. Timer-to-Close not set g. Close Entrapment Protection Device active
SOLUTIONS a. Check AC and battery power b. Check fuses c. Charge batteries by AC or solar power or replace batteries d. Replace defective control board a. Check reset switch b. Check Stop button is not “stuck on”, or verify that the stop button is a normally closed circuit, or put a jumper on the stop circuit.
c. Charges batteries by AC or solar power or replace batteries d. Check all Open and Close inputs for a “stuck on” input e. Check all Entrapment Protection Device inputs for a “stuck on” sensor f. Check all vehicle detector inputs for a “stuck on” detector g. Replace defective control board a. Use manual disconnect, manually move gate, and ensure gate moves easily limit to limit. Repair gate as needed.
b. Gate must move easily and freely through its entire range, limit to limit. Repair gate as needed.
c. Ensure the gate moves at least four feet between the OPEN limit and the CLOSE limit.
a. Use manual disconnect, manually move gate, and ensure gate moves easily limit to limit. Repair gate as needed.
b. Gate must move easily and freely through its entire range, limit to limit. Repair gate as needed.
a. Check all Open and Close inputs for a “stuck on” input b. Check Stop button is not “stuck on” c. Check Reset button d. Charges batteries by AC or solar power or replace batteries e. Check all Entrapment Protection Device inputs for a “stuck on” sensor f. Check all vehicle detector inputs for a “stuck on” detector a. Activate wireless control and check XMITTER LED is on. Relearn wireless control/transmitter to control board. Replace wireless control as needed.
b. Check Stop button is not “stuck on” c. Check Reset button d. Check if similar wired control operates correctly. Check if wireless controls works properly when within a few feet of operator. Check operator’s antenna and antenna wire. Check other wireless controls or devices.
a. Check all Open and Close inputs for an active input b. Check all vehicle detector inputs for an active detector c. Battery voltage must be 11.5 Vdc or higher. Charge batteries by
AC or solar power or replace batteries a. Check all Open inputs for an active input b. Check all vehicle detector inputs for an active detector c. Check AC power and AC Fail option setting d. Check if AC power is available. If no AC power, then running on batteries and battery voltage must be 11.5 Vdc or higher. Charge batteries by AC or solar power or replace batteries.
e. Check Fire Dept input f. Check Timer-to-Close (TTC) setting g. Check all Entrapment Protection Device inputs for an active sensor
37
TROUBLESHOOTING
SYMPTOM
Gate closes, but will not open.
POSSIBLE CAUSES a. Vehicle loop detector active b. Low battery with LOW BATT option set to
CLOSE
Obstruction in gate's path does not cause gate to stop and reverse.
Photoelectric sensor does not stop or reverse gate.
a. Force adjustment needed a. Incorrect photoelectric sensor wiring b. Defective photoelectric sensor
SOLUTIONS a. Check all vehicle detector inputs for an active detector b. Check if AC power is available. If no AC power, then running on batteries and battery voltage must be 11.5 Vdc or higher. Charge batteries by AC or solar power or replace batteries.
a. Refer to the Adjustment section to conduct the obstruction test and perform the proper force adjustment that is needed.
Edge Sensor does not stop or reverse gate.
Alarm sounds for 5 minutes or alarm sounds with a command.
Alarm beeps three times with a command.
On dual-gate system, incorrect gate opens first or closes first.
Alarm beeps when running.
Maglock not working correctly.
a. Incorrect edge sensor wiring b. Defective edge sensor a. Double entrapment occurred (two obstructions within a single activation) a. Low battery a. Incorrect Bipart switch setting a. Expansion board setting b. Constant pressure to open or close is given a. Maglock wired incorrectly
Solenoid lock not working correctly.
a. Solenoid wired incorrectly a. Check photoelectric sensor wiring. Retest that obstructing photoelectric sensor causes moving gate to stop, and may reverse direction.
b. Replace defective photoelectric sensor. Retest that obstructing photoelectric sensor causes moving gate to stop, and may reverse direction.
a. Check edge sensor wiring. Retest that activating edge sensor causes moving gate to stop and reverse direction.
b. Replace defective edge sensor. Retest that activating edge sensor causes moving gate to stop and reverse direction.
a. Check for cause of entrapment (obstruction) detection and correct. Press the reset button to shut off alarm and reset the operator.
a. Check if AC power is available. If no AC power, then running on batteries and battery voltage must be 11.5 Vdc or higher. Charge batteries by AC or solar power or replace batteries a. Change setting of both operator’s Bipart switch settings. One operator should have Bipart switch ON (operator that opens second) and the other operator should have Bipart switch OFF
(operator that opens first).
a. Pre-warning is set to "ON" b. Constant pressure to open or closed is given a. Check that Maglock is wired to N.C. and COM terminals. Check that Maglock has power (do not power maglock from control board accessory power terminals). If shorting lock’s NO and
COM wires does not activate Maglock, then replace Maglock or
Maglock wiring (refer to Wiring Diagrams).
a. Check that Solenoid is wired to N.O. and COM terminals. Check that Solenoid has power (do not power solenoid from control board accessory power terminals). If shorting lock’s NC and
COM wires does not activate Solenoid, then replace Solenoid lock or Solenoid wiring (refer to Wiring Diagrams).
a. Learn the limits Switched (SW)
Accessory power remaining on.
Accessories connected to Switch
(SW) Accessory power not working correctly, turning off, or resetting.
a. In limit setup mode a. Normal behavior a. Move accessory to accessory power "ON"
38
TROUBLESHOOTING
SYMPTOM
Accessories connected to
Accessory power not working correctly, turning off, or resetting.
Solar operator not getting enough cycles per day.
POSSIBLE CAUSES a. Accessory power protector active b. Defective control board a. Insufficient panel wattage b. Excessive accessory power draw c. Old batteries d. Solar panels are not getting enough sunlight
Solar operator, insufficient standby time.
a. Insufficient panel wattage b. Excessive accessory power draw c. Battery capacity too low
SOLUTIONS a. Disconnect all accessory powered devices and measure accessory power voltage (should be 11.5 – 17.5 Vdc). If voltage is correct, connect accessories one at a time, measuring accessory voltage after every new connection.
b. Replace defective control board a. Add more solar panels b. Reduce the accessory power draw by using LiftMaster low power accessories c. Replace batteries d. Relocate the solar panels away from obstructions (trees, buildings, etc.) a. Add more solar panels b. Reduce the accessory power draw by using LiftMaster low power accessories c. Use batteries with higher amp hour (AH) rating
39
APPENDIX
Dual Gate Settings
NOTE: We recommend that all accessories and board configurations are set on the primary operator.
Main control board Accessories
FEATURE PRIMARY OPERATOR SECONDARY OPERATOR
ACCESSORY
Timer-to-
Close
Set the TTC dial to desired setting
OFF
Remote Controls
Bi-Part
Delay
Switch
Bi-Part Delay: ON (will open last and close first)
Tandem Mode: OFF
Synchronized Close: ON
Bi-Part Delay: OFF (will open first and close last)
Tandem Mode: OFF
Synchronized Close: ON
LiftMaster Internet
Gateway
Garage and Gate
Monitor
PRIMARY OPERATOR
Program remote controls 1 to 50 to the primary operator.
Program to primary operator.
Program to primary operator.
SECONDARY
OPERATOR
Program remote controls 51 to 100 to the secondary operator
40
APPENDIX
Step 6 Solar Panel(s)
SOLAR PANELS ARE NOT PROVIDED. SEE ACCESSORIES
Solar Application requirements:
• A minimum of one 10W solar panel (Model SP10W12V).
• A maximum of three 10W solar panels in parallel (Model SP10W12V).
• Battery Harness (Model K94-37236).
• One 7AH battery or one 33AH battery
• A heater cannot be used with a solar application.
Solar Zones
Solar panel recommendations are based upon the average solar radiation and the temperature effects on batteries in the given zones as shown on the map below. Local geography and weather conditions may require additional solar panels. Solar powered gate operator installations are not supported in northern climates due to cold weather and a reduced number of hours of sunlight during the winter months. The cycles/day ratings are approximations.
Ratings vary based on gate construction, installation, and temperature. Solar panels cannot be installed in areas that experience long periods of heavy fog, lake effect snow, or rain.
Solar zones
1
2
3
ZONE 1 (6 Hours of Sunlight/Day): Ideal for solar application
ZONE 2 (4 Hours of Sunlight/Day):
Recommended for solar application
ZONE 3 (2 Hours of Sunlight/Day): Success of solar application will depend on type of gate operator and location of the solar panel
NOT AVAILABLE
NOT AVAILABLE
1
2
3
1
41
APPENDIX
Solar usage guide
NOTE: For additional details and specifications on solar usage, please refer to liftmaster.com.
Typical System Standby Battery Current Consumption (mA)
System voltage
Control board with no radios programmed
One or more LiftMaster ® remote controls programmed myQ ® device or wireless dual gate programmed
Expansion board
Per loop detector LOOPDETLM (up to 3 loop detectors can be plugged in to the expansion board)
Add up current draw by feature and accessory to determine total current draw
NOTE: The use of photoelectric sensor heaters (models LMRRUL and LMTBUL) is NOT recommended in solar applications.
12V
4.2 mA
+1.5 mA
+3.9 mA
+18.5 mA
+6.6 mA
10W SOLAR
PANEL
20W SOLAR
PANEL (Two
10W 12V panels in parallel)
30W SOLAR
PANEL
(Three 10W
12V panels in parallel)
BATTERY
CURRENT
DRAW
(mA)
100
6
25
30
100
200
6
25
6
25
30
50
30
100
200
50
50
50
47
19
50
50
50
33
7AH batteries
33
27
26
21
ZONE 1
Two 7AH batteries
50
50
50
48
20
36
31
29
24
11
50
50
50
50
50
SOLAR GATE CYCLES PER DAY
ZONE 2
33AH batteries
50
50
27
13
50
50
50
50
50
50
50
38
33
31
26
7AH batteries
19
15
13
37
32
30
12
46
40
39
20
Two 7AH batteries
22
17
15
11
47
41
40
20
50
50
50
41
14
50
50
50
50
24
50
47
45
25
33AH batteries
23
28
17
12
7AH batteries
ZONE 3
Two 7AH batteries
33AH batteries
15
11
19
14
13
19
15
13
29
24
23
16
12
11
35
30
28
10
All numbers are estimates. Actual results may vary.
42
APPENDIX
Position
The location of the panel(s) is critical to the success of the installation. In general, the panel(s) should be mounted using the provided angle bracket facing due south . The solar panel(s) should be mounted in an area clear of all obstructions and shade from buildings and trees. If the panel(s) is not casting a shadow, the battery is not being charged.
NOTE: Tall trees or buildings that do not shade the solar panel(s) in the summer could shade the solar panel(s) during the winter months when the sun sits lower in the sky.
Sun’s position
AMERICAN
WIRE
GAUGE
(AWG)
16
MAXIMUM WIRE LENGTH
20 WATTS OF
PANELS
235 (71.6 m)
40 WATTS OF
PANELS
115 (35.1 m)
60 WATTS OF
PANELS
80 (24.4 m)
14
12
10
375 (114.3 m)
600 (182.9 m)
940 (286.5 m)
190 (57.9 m)
300 (91.4 m)
475 (144.8 m)
Chart assumes: copper wire, 65°C, 5% drop, 30V nominal
125 (38.1 m)
200 (61 m)
315 (96 m)
TIP: The area around the solar panel(s) should be clear of shadows or obstructions to the sun for a 180° arc east to west.
South
Summer Sun Height
Winter Sun Height
Up to 15°
180°
South
TIP: To optimize the system for winter operation the angle can be increased an additional 15° (solar panel(s) sits more vertical).
Installation
Solar panel(s) MUST be installed facing south. Use a compass to determine direction. Below are general instructions for installing the solar panel(s). Your installation may vary slightly depending on the solar panel purchased.
1. Position the mounting bracket on the mounting surface. Mark and drill holes.
2. Secure the solar panel to the mounting bracket using the hex bolts, hex nuts and washers provided.
3. Secure the solar panel to the mounting surface using lag screws provided.
Mounting Surface
Mounted Panel
Must Face South
43
Mounting Surface
APPENDIX
Wire the Batteries
Solar panel applications require the Solar Harness Kit model K94-37236, see Accessories .
To “BATT DC POWER” input on control board
To “BATT DC POWER” input on control board
To “BATT DC POWER” input on control board
ONE 7AH BATTERY
Wire the Solar Panels
10W APPLICATION
IN PARALLEL
To Solar Panels
Black jumper wire for two 7AH battery connections
Red jumper wire for two 7AH battery connections
Fuse
To Solar Panels
Red wire for
33AH battery connections To Solar Panels
Black wire for
33AH battery connections
TWO 7AH BATTERIES
IN PARALLEL
ONE 33AH BATTERY
20W APPLICATION
IN PARALLEL
30W APPLICATION
IN PARALLEL
To Battery(ies) To Battery(ies) To Battery(ies) To Battery(ies) To Battery(ies)
10W 10W 10W 20W
10W 10W
10W
Proceed to the Dual Gate section (if applicable) or proceed to the Adjustment section.
44
10W 20W
APPENDIX
Manual Adjustments with a Remote Control
To set the limits using a remote control, first you will need a 3-button remote control that has been programmed for OPEN, CLOSE, and STOP. Refer to the Programming section.
Enter Manual Setup Mode
NOTE: For dual gate applications the limits will have to be set for each operator. The gate MUST be attached to the operator before setting the limits and force.
8.
Press and release the CLOSE button on the remote control again to set the close limit.
9.
Upon successfully setting Limits for your gate setup, the manual setup mode will exit.
NOTE: While setting the Limits, all entrapment protection devices will be disconnected, and the Remote Control buttons can be used to move the gate as needed. During the Automatic Force Setup, all entrapment protection devices will be reconnected, and the gate will automatically open and close.
Refer to the Adjustment section and follow the instructions for Fine Tune the Force and Obstruction Test .
Perform the "Obstruction Test" after every limit and force setting adjustment.
Adjust the limits
Ensure the gate is closed.
If the limits have already been set the operator will exit the Manual Setup
Mode after resetting each limit.
1. To enter manual set up mode, make sure that both SET OPEN and
SET CLOSE LEDs are flashing. If they are not flashing, press and release both the SET OPEN and SET CLOSE buttons.
Set the Close Limit Only
1. Press and release the SET OPEN and SET CLOSE buttons simultaneously to enter Manual Setup Mode.
Reversal Force Dial
2.
The REVERSAL FORCE DIAL is set to minimum at the factory. You will be able to adjust the force setting after the initial Manual Setup.
2. Press and hold the CLOSE button on the remote control until the gate reaches the desired close position. The gate can be jogged back and forth using the OPEN and CLOSE buttons on the remote control.
Once initial limits have been set, the REVERSAL FORCE dial on the
Control Board is used to fine tune the force where wind or
3. Once the gate is in the desired close position, press and release the
STOP button on the remote control.
environmental changes may affect the gate travel.
4. Press and release the CLOSE button on the remote control again to set the close limit.
Settings 1-10: Automatically increase the force due to gate wear or temperature changes.
When the close limit is set properly the operator will automatically exit
Manual Setup Mode and enter Automatic Force Setup Mode.
Set the Limits
Set the Open Limit Only
3.
Press and hold the OPEN or CLOSE button on the remote control until the gate reaches the desired open position. The gate can be jogged back and forth using the OPEN and CLOSE buttons on the remote control.
4.
Once the gate is in the desired open position, press and release the
STOP button on the remote control.
5.
Press and release the OPEN button on the remote control again to set the open limit.
1. Press and release the SET OPEN and SET CLOSE buttons simultaneously to enter Manual Setup Mode.
2. Press and hold the OPEN button on the remote control until the gate reaches the desired open position. The gate can be jogged back and forth using the OPEN and CLOSE buttons on the remote control.
3. Once the gate is in the desired open position, press and release the
STOP button on the remote control.
6.
Press and hold the CLOSE or OPEN button on the remote control until the gate reaches the desired close position. The gate can be jogged back and forth using the OPEN and CLOSE buttons on the remote control.
4. Press and release the OPEN button on the remote control again to set the open limit.
When the open limit is set properly the operator will automatically exit
Manual Setup Mode and enter Automatic Force Setup Mode.
7.
Once the gate is in the desired close position, press and release the
STOP button on the remote control.
3-Button Remote Control programmed for OPEN, CLOSE, and STOP
DIAGNOSTICS
45
WIRING DIAGRAM
To protect against fire and electrocution:
• DISCONNECT power (AC or solar and battery) BEFORE installing or servicing operator.
For continued protection against fire:
• Replace ONLY with fuse of same type and rating.
Black
Red
To J25
Antenna
Coaxial Antenna Cable
DIAGNOSTICS
J25
AC & BATT FAIL
BACKDRIVE
CONTROL BOARD
Jumper Wire
+
+
-
+
+
-
N.C.
-
+
-
+
-
+
-
+
Photoelectric Sensors
Photoelectric Sensors
Primary/Secondary link to other gate operator
Shielded
Twisted
Pair Cable
Ground the shield of the cable to the chassis ground of each operator.
Red
Black
Blue
Yellow
Transformer
Accessory Power
Outlets
12V 7AH Battery
Red
Black
Product ID
Piezo
Alarm
Blocking
Diode
-
+ -
+
To Pin 2
To Pin 6
To Pin 1
To Pin 5
Reset Switch
Run
Stop/Reset
One, two, or three 10W Solar Panels wired in parallel (30W maximum)
EXPANSION BOARD (Optional)
1/8 HP 12 Vdc
Motor
APS Encoder
Loop
Detector
Wireless edge
Eye
Edge or Eye
Edge or Eye
Heater
N.C.
Input Power Connection
Jumper Wire
Field Wiring
Wire Loop
Wire Loop
Field Wiring
Wire Loop
46
Timing Belt, 3M
K16-GT2-9
Gear Reducer Pulley and Motor Pulley
K17-37318
Motor ,
1/8 HP, 12 Vdc
K76-37253
REPAIR PARTS
APS Encoder , 12V
K76-34697-3
Alarm with harness
K76-37298
NOT SHOWN
29-NP712 Battery, 7AH, 12 Vdc
K74-30762 Two 7AH batteries
K94-37267 Battery Harness (for 7AH batteries)
K94-37236 Battery Harness (for 33AH batteries)
K1A6408 APE Assembly with plastic tray, RPM board with mounting hardware
K94-37259 Wiring Harness with product ID
1941240D #41 Chain (10 feet)
1950307 #41 Master Link
K77-36764 Hardware: Chain Eye-bolts with Nuts, Chain Bracket (2),
Crank Handle
Q003 Chain Bolt
Gear Reducer
K32-34701-5
Reset Switch
K180A0357
Output Sprocket
K15-41B16GKEH
Idler Pulley with hardware
Q013
Chassis
K73-37060
Electrical Box
K77-37319
Operator Cover with labels
K77-37857 (Gray)
Antenna
K77-36541
Main Board with heat sink
K1D8389-1CC
Dust Guard
K13-34729
120V receptacle assembly
K76-37016
Plug-in Transformer
APOW3
47
ACCESSORIES
Entrapment Protection
LiftMaster monitored through beam photoelectric sensor
Model LMTBUL
LiftMaster monitored retro-reflective photoelectric sensor
Model LMRRUL
LiftMaster Monitored Commercial Protector
System ®
Models CPS-UN4 and CPSUN4G
LiftMaster monitored wireless edge kit
(transmitter and receiver)
Model LMWEKITU
Remote Controls
LiftMaster offers a variety of LiftMaster remote controls to satisfy your application needs. Single-button to 4-button, visor or key chain. The following remote controls are compatible with operators manufactured by LiftMaster after 1993. Contact your authorized LiftMaster dealer for additional details and options.
3-button remote control
The 3-button remote control can be programmed to control the operator. Includes visor clip.
Model 893MAX
3-button mini-remote control
The 3-button remote control can be programmed to control the operator. Includes key ring and fastening strip.
Model 890MAX
Security+ 2.0
® learning remote controls
One button can control a gate operator and the other(s) can control garage door(s). It can also be programmed to
Security+ ® or Security+ 2.0
® code format.
Models 892LT and 894LT
LiftMaster monitored wireless edge transmitter
Model LMWETXU
Keyless entry
Enables homeowner to operate gate operator from outside by entering a 4-digit code on a specially designed keypad.
Model 878MAX
Large profile monitored edge (82 ft. roll)
Model L50
Large profile ends kit (10 pair)
Model L50E
Small profile monitored edge (82 ft. roll)
Model S50
Small profile ends kit (10 pair)
Model S50E
Plastic channel
8 ft. (2.4 m) for both small and large profile edges (pack of 10).
Model L50CHP
Aluminum channel
10 ft. (3.1 m) for both small and large edge profiles (pack of 8).
Model L50CHAL
Edge cutting tool
Model ETOOL
LiftMaster large profile monitored edges (4ft., 5ft., 6ft.)
Model L504AL, L505AL, L506AL
LiftMaster small profile monitored edges (4ft.,5ft., 6ft.)
Model S504AL, S505AL, S506AL
Wraparound round monitored edge (4 ft., 5 ft., 6 ft.)
Models WR4, WR5, WR6
Wraparound square monitored edge (4 ft.,5 ft., 6 ft.)
Models WS4, WS5, WS6
48
ACCESSORIES
Miscellaneous
Remote antenna extension kit
The remote antenna extension kit allows the antenna to be remotely installed.
Model 86LM
Commercial access control receiver
Access control receiver for up to 1,000 devices (any combination of remote controls and wireless keyless entries).
Model STAR1000
LiftMaster ® Internet Gateway
Internet enabled accessory which connects your gate operator to your WiFi network and allows you to monitor and control gate operators and lighting accessories enabled by myQ ® technology.
Model 828LM
Expansion board
Additional programming features including external loops, plug-in loops, auxiliary relays, and inputs for additional controls and entrapment protection devices.
Model K1D8387-1CC
Mounting stand
For Model RSL Slide. Ideal to raise slide operator higher above the ground for snow and other applications.
Model MSLM
Plug-in loop detector
Low power. Conveniently plugs into existing control board. Not to be used as entrapment protection.
Model LOOPDETLM
Loop detector
Low power loop detectors mounted and wired separately inside control box. LiftMaster low power accessory. Not to be used as entrapment protection.
Model LD7LP
Vehicle sensing probe
The vehicle sensing probe is buried in the ground and can detect a car as it approaches and will then open the gate.
Model CP4
Solar panel kit
This kit is to replace or add a solar panel to the operator application. 60W maximum for 24 Vdc operators and 30W maximum for 12 Vdc operators.
Requires a 33AH battery harness.
Models SP10W12V (10 Watt, 12V) and SP20W12V
(20 Watt, 12V)
Magnetic gate lock
Outdoor magnetic lock, transformer, junction box, mounting plate and hardware. Not for use with Solar
Applications. Must be powered separately.
Model MG1300
Heater
The heater keeps the gearbox and batteries at a suitable temperature when the outside temperature is below -4°F (-20°C). The thermostat MUST be set between 45°F and 60°F (7°C and 15.5°C) to ensure proper gate operation. The heater can be powered by
110 to 250 Vac.
Model HTR
Wire harness
Between main control board and expansion board.
Model K94- 34778
40-39235-1
Wireless commercial keypad
Durable wireless keypad with blue LED backlight metal keypad, zinc-alloy metal front cover and 5 year 9V lithium battery. Security+ 2.0
® compatible.
Model KPW250
Warning sign
Model 40-39235
Batteries
Gate access system batteries replace or upgrade the gate operator batteries. Two identical 12 Vdc batteries are required for each gate operator. Do not mix 7AH and
33AH batteries within a gate operator.
7AH batteries
Standard 7 AMP-Hour Battery, 12 Vdc, to replace original batteries provided with operator. Reuse existing harnesses.
Models 29-NP712 (1) and K74-30762 (2)
33AH batteries
Upgrade 33 AMP-Hour Battery, 12 Vdc. Ideal for solar applications and extended battery backup. Two required.
Model A12330SGLPK
Universal solar wire harness kit
For 7AH and 33AH applications.
Model K94-37236
49
WARRANTY
Three Year Limited Warranty
LiftMaster warrants to the first purchaser of this product, for the structure in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of THREE years from the date of purchase. The proper operation of this product is dependent on your compliance with the instructions regarding installation, operation, maintenance and testing. Failure to comply strictly with those instructions will void this limited warranty in its entirety.
If, during the limited warranty period, this product appears to contain a defect covered by this limited warranty, call 1-800-528-2806 , toll free, before dismantling this product. Then send this product, pre-paid and insured, to our service center for warranty repair. You will be advised of shipping instructions when you call. Please include a brief description of the problem and a dated proof-of purchase receipt with any product returned for warranty repair. Products returned to Seller for warranty repair, which upon receipt by Seller are confirmed to be defective and covered by this limited warranty, will be repaired or replaced (at Seller’s sole option) at no cost to you and returned pre-paid. Defective parts will be repaired or replaced with new or factory-rebuilt parts at Seller’s sole option.
ALL IMPLIED WARRANTIES FOR THE PRODUCT, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE THREE YEAR LIMITED WARRANTY PERIOD SET FORTH ABOVE, AND
NO IMPLIED WARRANTIES WILL EXIST OR APPLY AFTER SUCH PERIOD. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. THIS LIMITED WARRANTY DOES NOT COVER NON-DEFECT DAMAGE, DAMAGE CAUSED BY
IMPROPER INSTALLATION, OPERATION OR CARE (INCLUDING, BUT NOT LIMITED TO ABUSE, MISUSE, FAILURE TO PROVIDE REASONABLE AND
NECESSARY MAINTENANCE, UNAUTHORIZED REPAIRS OR ANY ALTERATIONS TO THIS PRODUCT), LABOR CHARGES FOR REINSTALLING A
REPAIRED OR REPLACED UNIT, OR REPLACEMENT OF BATTERIES.
THIS LIMITED WARRANTY DOES NOT COVER ANY PROBLEMS WITH, OR RELATING TO, THE GATE OR GATE HARDWARE, INCLUDING BUT NOT
LIMITED TO THE GATE SPRINGS, GATE ROLLERS, GATE ALIGNMENT OR HINGES. THIS LIMITED WARRANTY ALSO DOES NOT COVER ANY
PROBLEMS CAUSED BY INTERFERENCE. ANY SERVICE CALL THAT DETERMINES THE PROBLEM HAS BEEN CAUSED BY ANY OF THESE ITEMS
COULD RESULT IN A FEE TO YOU.
UNDER NO CIRCUMSTANCES SHALL SELLER BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES ARISING IN CONNECTION
WITH USE, OR INABILITY TO USE, THIS PRODUCT. IN NO EVENT SHALL SELLER’S LIABILITY FOR BREACH OF WARRANTY, BREACH OF
CONTRACT, NEGLIGENCE OR STRICT LIABILITY EXCEED THE COST OF THE PRODUCT COVERED HEREBY. NO PERSON IS AUTHORIZED TO
ASSUME FOR US ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF THIS PRODUCT.
Some states do not allow the exclusion or limitation of consequential, incidental or special damages, so the above limitation or exclusion may not apply to you. This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
50
APPENDIX
51
300 Windsor Drive
Oak Brook, IL 60523
LiftMaster.com
© 2022, The Chamberlain Group LLC. - All Rights Reserved