- Home
- Home security & automation
- Carbon monoxide (CO) detectors
- gascliptech
- Multi-Gas Clip Simple
- User Guide
gascliptech Multi-Gas Clip Simple User Guide
Add to My manuals2 Pages
gascliptech Multi-Gas Clip Simple is a personal safety device designed to detect hydrogen sulfide (H2S), carbon monoxide (CO), oxygen (O2), and combustible gases (LEL). With its 24-month lifespan, it provides continuous protection against these hazardous gases. The device features visual, vibrating, and audible alarms to alert you in case of unsafe gas levels. The Multi-Gas Clip Simple is easy to operate and can be activated with a simple press of a button. It also offers auto-zeroing functionality to ensure accurate readings.
advertisement
Battery Information
This detector is designed so that the battery won’t need charging or replacing during the life of the detector.
Detector Life Countdown
Once activated, the detector will display 24 months of life remaining. Detector will continue to countdown and display months remaining until 30 days remain. Display will then show days remaining until end of life.
Additional Questions?
For additional information on the Multi Gas Clip Simple gas detector regarding programming, bump testing, calibrating, etc., please refer to the
Multi Gas Clip Simple User’s Manual . The manual and other helpful videos
& information are available for viewing or download at www.gascliptech.com.
Contact Information
Gas Clip Technologies, Inc.
305 W. FM 1382, Suite 540
Cedar Hill, TX 75104 USA
Phone: +1.972.775.7577
Fax: +1.972.775.2483
Toll Free: 1.877.525.0808
E-mail: [email protected]
Website: www.gascliptech.com
A
SS
EM
BLED IN U
SA
Portable gas detectors you can count on
MGC-S QSG v1.03
Portable gas detectors you can count on
Multi Gas Clip
Simple
Quick-Start Guide
READ FIRST BEFORE OPERATION
The Multi Gas Clip Simple is a personal safety device designed to detect the presence of hydrogen sulfide (H2S), carbon monoxide (CO), oxygen (O2) and combustible gases (LEL). Before operation, ensure that you have been properly trained on the use of the detector and the appropriate actions to take in the event of an alarm condition.
1 2
Display Components
3
6
4
5
Icon
1
2
3
4
5
6
Description
Alarm Condition
Life Remaining
Calibration/Test Mode
Battery Indicator
Gas Readings
Gas Identifiers
When a Gas Reading (5) exceeds its alarm threshold, the detector will go into visual, vibrating and audible alarm. On the display, the icon will appear beside the Alarm Condition (1) and the associated Gas Identifier (6) will flash off and on continuously.
Warning - Users must familiarize themselves with the icons in both alarm and non-alarm states.
Warning - If the display is missing icons, or cannot be clearly read, discontinue use and contact Gas Clip Technologies.
Warning - The IR LEL sensor will not detect hydrogen (H2) or acetylene
(C2H2) gases however, due to their cross-sensitive nature, the CO sensor will go into alarm well below 10% LEL.
Sensor
H
2
S
CO
O
2
LEL
Factory Default Alarms
LOW HIGH
10 ppm 15 ppm
35 ppm 200 ppm
19.5%
10%
23.5%
20%
TWA
10 ppm
35 ppm
STEL
15 ppm
50 ppm
Turning On the Detector
Once activated, the detector will run continuously for 24 months. To activate, press and briefly hold down the power/menu button. The detector will begin to display Gas Readings (5) immediately. Each Gas Identifier (6) will show a chasing “0” for the Gas Reading (5) while it is stabilizing and self-testing. Once all Gas Identifiers (6) have completed the warm up and stabilization sequence, <65 seconds, the detector is ready to detect all applicable gases.
Display will show:
Stabilizing Fully operational
Warning - Before each use, check that all sensor and alarm ports are clear of any debris or obstructions.
Bump Testing and Calibrating
These operations can be performed manually or automatically using the
MGC Simple Clip Dock . Refer to the Multi Gas Clip Simple User’s Manual for instructions.
Auto Zeroing
Continuously hold down the power/menu button to auto zero the detector.
Display will show “ZERO” and count down from 3 to 1, followed by “ZERO OK”.
Release button when display shows “ZERO OK”. The display will change to
“AUTO ZERO”. Wait a few seconds, then press the button briefly when display shows “APPLY GAS”. Detector has been successfully auto zeroed.
Warning - DO NOT auto zero the detector in a combustible atmosphere.
Warning - DO NOT auto zero in temperatures above 104°F
(40°C) or below 32°F (0°C).
advertisement