MAJOR TECH MT668 Temperature and Humidity Data Logger Instruction manual
Major Tech MT668 is a compact and reliable data logger designed to accurately measure and record temperature and humidity readings over an extended period. With its large memory capacity of 32,000 readings, it ensures continuous data collection for various applications, including environmental monitoring, food storage, and scientific research.
Advertisement
Advertisement
INSTRUCTION MANUAL
MT668
TEMPERATURE & HUMIDITY
DATA LOGGER
2
Contents
Page no
1. Features...........................................................................................4
2. Description.......................................................................................4
3. LED Status Guide...............................................................................5
4. Specifications...................................................................................6
4.1. Safety Precautions....................................................................6
4.2. Temperature............................................................................6
4.3. Dew Point Temperature..............................................................6
4.4. General....................................................................................7
5. Battery Replacement.........................................................................7
6. Sensor Reconditioning.......................................................................7
3
4
1. FEATURES
Ÿ Memory for 32,000 readings (16 000 temperature and 16 000 humidity readings)
Ÿ Dew point indication
Ÿ Status Indication
Ÿ USB Interface
Ÿ User-Selectable Alarm
Ÿ Analysis software
Ÿ Multi-mode to start logging
Ÿ Long battery life
Ÿ Selectable measuring cycle:
2s, 5s, 10s, 30s, 1m, 5m, 10m, 30m, 1hr, 2hr, 3hr, 6hr, 12hr, 24hr
2. INSTRUMENT LAYOUT
1 - Protective cover
2 - USB connector to PC port
3 - Start button
4 - RH and Temperature sensors
5 - Alarm LED (red/yellow)
6 - Record LED (green)
7 - Mounting clip LED STATUS GUIDE
3. LED STATUS GUIDE
LEDs
REC ALM
Indication
Both LED lights OFF
Logging not active or Low
Battery
REC ALM One green flash every 10 sec*
Ÿ Logging, no alarm condition**
Green double flash every
10 sec*.
Ÿ Delayed start
Action
Start logging. Replace the battery and download the data
To start, hold the start button until Green and
Yellow LED flash
REC
REC
ALM
ALM
Red single flash every 10 sec*
Logging will stop automatically. No data
Ÿ Logging, low alarm for
RH*** battery and download the
Red double flash every 10 data.
sec*
Ÿ Logging, high alarm for
RH***
Red single flash every 60 seconds.
Ÿ Low Battery****
Yellow single flash every 10 Download the data.
sec*
Ÿ Logging, low alarm for
TEMP***
Yellow double flash every
10 sec*
Ÿ Logging, high alarm for TEMP***
Yellow single flash every
60 seconds.
Ÿ Logger memory full
* To save power, the logger's LED flashing-cycle can be changed to
20s or 30s via the supplied software.
** To save power, alarm LEDs for temperature and humidity can be disabled via the supplied software.
Ÿ *** When both temperature and relative humidity readings exceed alarm
5
6 level synchronously, LED status indication alternate every cycle. For example: If there is only one alarm, the REC LED blinks for one cycle and alarm LED will blink for next cycle. If there are two alarms, REC
LED will not blink. First alarm will blink for first cycle and the next alarm will blink for next cycle.
**** When the battery is low, all operations will be disabled automatically.
NOTE: Logging automatically stops when the battery weakens
(logged data will be retained). The supplied software is required to restart logging and to download logged data.
***** To use the delay function. Run the data logger Graph software, click on the computer icon on the menu bar (2nd from left) or select
LOGGER SET from the LINK pull-down menu. The Setup window will appear, and you will see there are two options: Manual and Instant.
If you select the Manual option, after you click the Setup button, the logger will not start logging immediately until you press the yellow button in logger's housing.
4. SPECIFICATIONS
4.1. Relative Humidity
Function
Overall Range
Accuracy (0 to 20 and 80 to 100%)
Accuracy (20 to 40 and 60 to 80%)
Accuracy (40 to 60%)
Range
0 to 100%
±5.0%
±3.5%
±3.0%
4.2. Temperature
Function Range
Overall Range
Accuracy (-40 to +14°F) and
(104 to 158°F)
-40 to 70°C (-40 to 158°F)
Accuracy (-40 to -10°C) and (40 to 70°C) ±2°C
Accuracy (-10 to +40°C) ±1°C
±3.6°F
Accuracy (14 to 104°F) ±1.8°F
4.3. Dew point Temperature
Function
Overall Range
Accuracy (25°C, 40 to 100%RH)
Range
-40 to 70°C (-40 to 158°F)
±2.0°C (±4.0°F)
4.4. General
Function Range
Operating temperature -35 to 80°C (-31 to 176°F)
Battery type 3.6V lithium (1/2AA) (SAFT LS14250, Tadiran
TL-5101 or equivalent)
Battery life
Dimensions/Weight
1 year (typ.) depending on logging rate, ambient temperature & use of Alarm LEDs
101 x 25 x 23mm / 172g
5. BATTERY REPLACEMENT
Only use 3.6V lithium batteries. Before replacing the battery, remove the model from the PC. Follow diagrammatic and explanation steps 1 through 4 below:
1. With a pointed object (e.g. a small screwdriver or similar), open the casing. Lever the casing off in the direction of the arrow.
2. Pull the data logger from the casing.
3. Replace/Insert the battery into the battery compartment observing the right polarity. The two displays briefly light up for control purposes
(alternating, green, yellow, green).
4. Slide the data logger back into the casing until it snaps into place. Now the data logger is ready for programing.
NOTE:
Leaving the model plugged into the USB port for longer than necessary will cause some of the battery capacity to be lost.
WARNING: Handle lithium batteries carefully, observe warnings on battery casing. Dispose of in accordance with local regulations.
6.SENSOR RECONDITIONING
Over time, the internal sensor may be compromised because of pollutants, chemical vapors, and other environmental conditions which can lead to inaccurate readings. To recondition the internal sensor, please follow the procedure below:
Bake the Logger at 80°C (176°F) at <5%RH for 36 hours followed by 20-
30°C (70-90°F) at>74%RH for 48 hours (for re-hydration)
If permanent damage to the internal sensor is suspected, replace the
Logger immediately to insure accurate readings.
7
MAJOR TECH
(PTY) LTD
South Africa Australia
www.major-tech.com
www.majortech.com.au
[email protected]
[email protected]
Download
Advertisement