User manual
VL53L1X API user manual
Introduction
The VL53L1X is a long distance ranging Time-of-Flight sensor.
The purpose of this user manual is to describe the set of functions to call to get ranging data using the VL53L1X driver. Please refer to the VL53L1X datasheet.
Figure 1. VL53L1X ranging sensor module
March 2018 DocID031478 Rev 1 1/28 www.st.com
28
1
2
Contents
Contents
3
2/28
UM2356
VL53L1X system overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Ranging API function descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Autonomous ranging description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Mandatory ranging functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Waiting for a result: polling or interrupt . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Stop a measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Timing budget and inter-measurement period . . . . . . . . . . . . . . . . . . . . . 9
Region of Interest (ROI) setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Spad array coordinates versus scene . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Optical center coordinates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
VDDIO configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
RangingMeasurementData structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Calibration functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
RefSPAD calibration function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
RefSPAD calibration procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Getting RefSPAD calibration results . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Setting RefSPAD calibration data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
DocID031478 Rev 1
4
5
6
UM2356 Contents
Offset calibration function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Offset calibration procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Getting offset calibration results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Setting offset calibration data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Cross talk calibration function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Cross talk calibration procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Crosstalk calibration distance characterization . . . . . . . . . . . . . . . . . . . 21
Getting crosstalk calibration results . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Setting crosstalk calibration data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Enable/Disable crosstalk compensation . . . . . . . . . . . . . . . . . . . . . . . . 23
Driver errors and warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Acronyms and abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
DocID031478 Rev 1 3/28
28
VL53L1X system overview
1 VL53L1X system overview
UM2356
The VL53L1X system is composed of the VL53L1X module and a driver running on the host.
Figure 2. VL53L1X system
s>ϱϯ>ϭy ƌŝǀĞƌ s>ϱϯ>ϭy^LJƐƚĞŵ s>ϱϯ>ϭy ŵŽĚƵůĞ
/Ϯ
ST delivers a software driver, referred to as the “driver” in this document.
This document describes the driver functions accessible to the host, to control the device and get the ranging data.
The driver is an implementation of a set of functions for using the VL53L1X device. It makes minimal assumptions on the OS integration and services. As such, sequencing of actions, executing/threading model, platform adaptation, and device structure allocation are not part of the driver implementation but are left open to the software integrator.
The sequencing of the function calls must follow a set of rules, defined in this document.
4/28 DocID031478 Rev 1
UM2356
2
Ranging API function descriptions
Ranging API function descriptions
This section give a functional description of the ranging and describes the API call flow that should be followed to perform a ranging measurement using the VL53L1X.
2.1 Autonomous ranging description
The sensor performs the ranging continuously and autonomously with a programmable inter-measurement period.
Ranging is done without involvement from the host which allows the host to be in a lowpower state. The host is only woken up upon measurement interrupts when a ranging is available.
It is possible to set a threshold of distance and/or signal detection criteria, then an interrupt is raised when the criteria is met.
The timing budget is defined as the programmed time needed by the sensor to perform and report ranging measurement data. During this time, the VCSEL is pulsed. An interrupt is raised or the date ready register is updated at the end of the timing budget.
The inter-measurement period is defined as the programmed time between two consecutive measurements.
Figure 3 shows the timing budget and inter-measurement period.
The host can change the default timing budget and inter-measurement period by using a
dedicated driver function described in Section 2.5.2: Timing budget and inter-measurement period .
The host can decide to change the timing budget to improve ranging accuracy or maximum distance limits.
Figure 3. VL53L1X autonomous ranging sequence and timings
3RZHU6XSSO\
;6KXW
*3,2,QWHUUXSW
'ULYHU&RPPDQG
6\VWHP6WDWH
6WDUW
5DQJLQJ
6:6WDQGE\
*HW
5DQJ
&OHDU
,QW
,QLW
5DQJLQJ
5DQJLQJ
7LPLQJ%XGJHW
,QWHU0HDVXUHPHQW
,QWHU0HDVXUHPHQW3HULRG
*HW
5DQJ
6WRS
5DQJ
5DQJLQJ
5DQJLQJ
7LPLQJ%XGJHW
,QWHU0HDVXUHPHQW 6:6WDQGE\
DocID031478 Rev 1 5/28
28
Ranging API function descriptions
2.3 API function call flows
The VL53L1X driver is used in two use cases:
• Calibration flow for device calibration
• Ranging flow used at user applications level
Calibration flow is described in
All API functions for calibration are described in Section 3: Calibration functions .
Figure 4. VL53L1X calibration flow tĂŝƚĞǀŝĐĞŽŽƚĞĚ;Ϳ
ĂƚĂ/Ŷŝƚ;Ϳ
^ƚĂƚŝĐ/Ŷŝƚ;Ϳ
WĞƌĨŽƌŵZĞĨ^ƉĂĚDĂŶĂŐĞŵĞŶƚ;Ϳ
WĞƌĨŽƌŵKĨĨƐĞƚĂůŝďƌĂƚŝŽŶ;Ϳ
WĞƌĨŽƌŵyƚĂůŬĂůŝďƌĂƚŝŽŶ;Ϳ
'ĞƚĂůŝďƌĂƚŝŽŶĂƚĂ;Ϳ
^ĂǀĞƉĂƌƚĐĂůŝďƌĂƚŝŽŶĚĂƚĂ
<ĞLJ
,ŽƐƚĐĂůůƐKƉƚŝŽŶĂůĚƌŝǀĞƌĨƵŶĐƚŝŽŶ
,ŽƐƚĂĐƚŝŽŶ
UM2356
6/28 DocID031478 Rev 1
UM2356 Ranging API function descriptions
Ranging flow is described in
Figure 5. VL53L1X ranging flow
<ĞLJ
,ŽƐƚĂĐƚŝŽŶ
,ŽƐƚĐĂůůƐĚƌŝǀĞƌ
ĨƵŶĐƚŝŽŶ
ĂƚĂƌĞƐƵůƚ ƌŝǀĞƌŝŶƚĞƌŶĂů
ĂĐƚŝŽŶ
,ŽƐƚĐĂůůƐKƉƚŝŽŶĂů
ĚƌŝǀĞƌĨƵŶĐƚŝŽŶƐ tĂŝƚĞǀŝĐĞŽŽƚĞĚ;Ϳ
ĂƚĂ/Ŷŝƚ;Ϳ
^ƚĂƚŝĐ/Ŷŝƚ;Ϳ
KƉƚŝŽŶĂůĂŶĚͬŽƌ^ĞƚĂůŝďƌĂƚŝŽŶ
ĨƵŶĐƚŝŽŶƐĐĂůů
^ƚĂƌƚDĞĂƐƵƌĞŵĞŶƚ;Ϳ
,ŽƐƚƉŽůůŝŶŐŵŽĚĞ
WŽůůŝŶŐͬ ŝŶƚĞƌƌƵƉƚ
'ĞƚDĞĂƐƵƌĞŵĞŶƚĂƚĂZĞĂĚLJ;Ϳ
ŚĞĐŬƐ ŝŶƚĞƌƌƵƉƚƐƚĂƚƵƐ ƌŝǀĞƌƉŽůůŝŶŐŵŽĚĞ tĂŝƚDĞĂƐƵƌĞŵĞŶƚĂƚĂZĞĂĚLJ;Ϳ
WŽůůƐŽŶ ŝŶƚĞƌƌƵƉƚƐƚĂƚƵƐ
/ŶƚĞƌƌƵƉƚŵŽĚĞ
/ŶƚĞƌƌƵƉƚƌĞĐĞŝǀĞĚ
'ĞƚZĂŶŐŝŶŐDĞĂƐƵƌĞŵĞŶƚĂƚĂ;Ϳ
ĂƚĂ ůĞĂƌ/ŶƚĞƌƌƵƉƚŶĚ^ƚĂƌƚDĞĂƐƵƌĞŵĞŶƚ;Ϳ ůĞĂƌƐ ŝŶƚĞƌƌƵƉƚ
ŶĂďůĞƐŶĞdžƚ ƌĂŶŐŝŶŐ
ŽŶƚŝŶƵĞ
͍
^ƚŽƉDĞĂƐƵƌĞŵĞŶƚ;Ϳ
KEd/Eh
DocID031478 Rev 1 7/28
28
Ranging API function descriptions
2.4 Mandatory ranging functions
UM2356
The following sections shows the API functions required to perform system initialization, before starting a measurement.
The
VL53L1_DataInit()
function is called once. It performs device initialization.
It is called once and only once after the device is brought out of reset.
The
VL53L1_StaticInit()
function allows loading of the device settings that are specific for a given use case.
2.4.4
The
VL53L1_StartMeasurement()
function must be called to start a measurement.
Waiting for a result: polling or interrupt
There are three ways to know that ranging data are available:
1.
The host can call a polling function to wait until ranging data are available,
The function
VL53L1_WaitMeasurementDataReady()
polls on the device interrupt status until ranging data are ready.
This function blocks all other operations on the host as long as the function is not completed, because an internal polling is performed.
2. The host can poll on a function to ask if the ranging data are available,
The host can poll on the function
VL53L1_GetMeasurementDataReady()
to know if new ranging data are ready.
This function does not block other operations. It is the preferred and recommended method if the sensor is used in polling mode.
3. The host can wait for a physical interrup t
An alternative and preferred way to get the ranging status is to use the physical interrupt output: by default, GPIO1 is pulled down when new ranging data are ready.
This pin is an output pin only, there is no input interrupt pin on this device.
The
Vl53L1_GetRangingMeasurementData() can be used to get ranging data.
When calling this function to get the device ranging results, a structure called
VL53L1_RangingMeasurementData_t is returned.
This structure is described in Section 2.6: RangingMeasurementData structure .
8/28 DocID031478 Rev 1
UM2356
2.4.6
Ranging API function descriptions
Clear source of interrupt
The interrupt must be cleared by calling the driver function:
VL53L1_ClearInterruptAndStartMeasurement() after reading the ranging data
To get consistent results, it is mandatory to call this function after getting the ranging measurement.
If this function is not called, the next ranging will start and the results will be updated. But, the data ready status flag will not be updated, and the physical interrupt pin will not be cleared.
The host can decide to stop the measurement by calling the
VL53L1_StopMeasurement()
function.
If the stop request occurs during a range measurement, then the measurement is aborted immediately.
2.5.1
2.5.2
Wait for boot
The
VL53L1_WaitDeviceBooted()
function ensures that the device is booted and ready.
This function is optional. It is a blocking function because there is an internal polling. This function should not be blocking for more than 4 ms, assuming 400 kHz I2C and 2 ms latency per transaction.
Timing budget and inter-measurement period
Timing budget is the time required by the sensor to perform one range measurement.
The
VL53L1_SetMeasurementTimingBudgetMicroSeconds() is the function to be used.
The minimum and maximum timing budgets are [20 ms, 1000 ms]
Example:
Status = VL53L1_SetMeasurementTimingBudgetMicroSeconds(&VL53L1Dev,
66000 ); sets the timing budget to 66 ms.
The function
VL53L1_GetMeasurementTimingBudgetMicroSeconds() gets the programmed timing budget.
The inter-measurement period is the delay between two ranging operations.
An inter-measurement period can be programmed. When a ranging completes, the device waits for the end of the programmed inter-measurement period before resuming the next ranging. In the inter-measurement period, the sensor is in a low-power state.
The
VL53L1_SetInterMeasurementPeriodMilliSeconds() is the function to be used.
DocID031478 Rev 1 9/28
28
Ranging API function descriptions
Note:
Note:
UM2356
Example:
Status = VL53L1_SetInterMeasurementPeriodMilliSeconds(&VL53L1Dev,
1000 ); sets the inter-measurement period to 1 s.
The function
VL53L1_GetInterMeasurementPeriodMilliSeconds() gets the programmed inter-measurement period.
If the inter-measurement period is shorter than the timing budget, once the device completes the ranging, the next ranging starts immediately.
The timing budget and inter-measurement period should not be called when the sensor is ranging. The user has to stop the ranging, change these parameters, and restart ranging.
Distance mode is a parameter provided to optimize the internal settings and tunings to get the best ranging performances depending on the ranging distance required by the application and the ambient light conditions.
The benefit of changing the distance mode is detailed in
Possible distance modes
Short
Medium
Long (default)
Table 1. Distance modes
Maximum distance Benefit / comments
Better ambient immunity Up to 1.3 m
Up to 3 m
Up to 4 m Maximum distance
The function to use is
VL53L1_SetDistanceMode() .
The user can call
VL53L1_GetDistanceMode() to get the programmed distance mode.
The driver uses two parameters to qualify the ranging measurement: signal and sigma.
If signal or sigma are outside the limits, the ranging is flagged as invalid (note that
RangeStatus is different than zero).
Applicable limits are:
• Sigma: VL53L1X_CHECKENABLE_SIGMA_FINAL_RANGE
Sigma is expressed in mm and is the estimation of the standard deviation of the measurement.
• Signal: VL53L1X_CHECKENABLE_SIGNAL_RATE_FINAL_RANGE
The signal rate measurement, expressed in MCPS, represents the amplitude of the signal reflected from the target and detected by the device.
10/28 DocID031478 Rev 1
UM2356 Ranging API function descriptions
Table 2 gives the default limit states and values.
Limit ID
Sigma
Signal
Table 2. Default limit states and values
Default limit state Default limit value Associated RangeStatus
Enabled
Enabled
15 mm
1 Mcps
1
2
If the user disables the limit checks, the ranging values will no longer be filtered and an incorrect measurement could be returned by the sensor. In this case, RangeStatus 1 and 2 will never be reported.
Changing limit default settings should be done with care, as the side effects can be important.
The limit change effects on the standard deviation and maximum ranging distances are
Limit ID
Sigma
Signal
Table 3. Signal and sigma limit change effects
Action
Effect on standard deviation
Effect on maximum ranging distance
Increase limit
Decrease limit
Increase limit
Decrease limit
-
+
+
-
+
-
-
+
VL53L1X_SetLimitCheckEnable()
and
VL53L1X_GetLimitCheckEnable()
are used to enable/disable a limit.
The limit value is set using
VL53L1X_SetLimitCheckValue()
and
VL53L1X_GetLimitCheckValue()
.
One example of the signal limit setting is to enable a signal check and set the limit to 0.4 MCps:
Status = VL53L1X_SetLimitCheckEnable(&VL53L1Dev,
VL53L1X_CHECKENABLE_SIGNAL_RATE_FINAL_RANGE, 1);
Status = VL53L1X_SetLimitCheckValue(&VL53L1Dev,
VL53L1X_CHECKENABLE_SIGNAL_RATE_FINAL_RANGE, 0.40*65536);
DocID031478 Rev 1 11/28
28
Ranging API function descriptions UM2356
2.5.5 Thresholds
The device can be configured to operate in distance and/or signal threshold detection mode.
The ranging data is reported to the host when the pre-configured criteria are matched.
Detection mode
Detection mode allows selection of the filtering conditions:
• 0: no filter (default value, standard ranging mode)
• 1: filter on distance criteria only
Distance detection mode, based on thresholds:
Distance detection mode (through the CrossMode parameter) defines the distance criteria:
• 0: below a certain distance: "threshold low"
– If object distance > distance low or no object found: no report
– If object distance < distance low and object found: report
• 1: beyond a certain distance: "threshold high"
– If object distance < distance high or no object found: no report
– If object distance > distance high and object found: report
• 2: out of a distance range (min/max), "out of window"
– Distance low < detected distance < distance high: no report
– Distance low > detected distance > distance high: report
• 3: Within a distance range (min/max), "inside window"
– Distance low > detected distance > distance high: no report
– Distance low < detected distance < distance high: report
Distance low is the minimum configured distance in millimeters.
Distance high is the maximum configured distance in millimeters.
No target
This is an alternate detection mode. In the standard use case, if no target is detected, no ranging is reported. Using no target detection mode (setting IntrNoTarget to 1) allows an interrupt to be generated when no target is present.
API function
VL53L1_SetThresholdConfig() is the function to use.
The VL53L1_DetectionConfig_t structure contains all parameters to be set.
12/28 DocID031478 Rev 1
UM2356
2.5.6
Ranging API function descriptions
Example:
Detectionconfig.DetectionMode = 1
Detectionconfig.Distance.CrossMode = 3
Detectionconfig.IntrNoTarget = 0
Detectionconfig.Distance.High = 1000
Detectionconfig.Distance.Low = 100
Status = VL53L1_SetThresholdConfig(&VL53L1Dev, & detectionConfig
);
This function is used to program the device to report ranging only when an object is detected within 10 cm and 1 m (as in this example).
The function
VL53L1_GetThresholdConfig() allows the programmed report threshold configuration to be obatined.
Region of Interest (ROI) setting
The receiving SPAD array of the sensor includes 16x16 SPADs which cover the full field of view (FoV). It is possible to program a smaller region of interest (ROI), with a smaller number of SPADs, to reduce the FoV.
To set a ROI different than the default 16x16 one, the user can call the
VL53L1_SetUserROI()
function.
The ROI is a square or rectangle defined by two corners: top left and bottom right.
Four coordinates are used to localize these two corners on the full SPAD array:
• TopLeftX
• TopLeftY
• BotRightX
• BotRightY
These coordinates are part of the VL53L1_UserRoi_t structure.
The user has to define the ROI coordinate values in the structure, and call the driver function to apply the ROI change.
The minimum ROI size is 4x4.
An example of an ROI setting is given in
DocID031478 Rev 1 13/28
28
Ranging API function descriptions
Figure 6. VL53L1X ROI setting example
7RS/HIW<
%RW5LJKW< hƐĞƌZŽŝ
UM2356
ϬϭϮϯϰϱϲϳϴϵϭϬϭϭϭϮϭϯϭϰϭϱ yy/^
The VL53L1_UserRoi_t structure contains the coordinates of an ROI:
• TopLeftX: 8 bit integer that gives the top left x coordinate [0;15]
• TopLeftY: 8 bit integer that gives the top left y coordinate [0;15]
• BotRightX: 8 bit integer that gives the bottom right x coordinate [0;15]
• BotRightY: 8 bit integer that gives the bottom right x coordinate [0;15]
Example to set one ROI (based on
) :
VL53L1_UserRoi_t roiConfig; roiConfig.TopLeftX = 9; roiConfig.TopLeftY = 13; roiConfig.BotRightX = 14; roiConfig.BotRightY = 10; status = VL53L1_SetUserROI(&VL53L1Dev, &roiConfig);
14/28 DocID031478 Rev 1
UM2356
2.5.7
Ranging API function descriptions
Spad array coordinates versus scene
Figure 7 shows the coordinates of an object in the SPAD array compared to the location in
the FoV.
Figure 7. VL53L1X coordinates vs scene
Due to assembly tolerances, the optical center of the device can vary. The optical center of the device is measured for each part. The optical center coordinates are stored in the device
NVM.
The user has access to the optical center coordinates by calling:
VL53L1_GetCalibrationData()
. The returned structure VL53L1_CalibrationData_t contains a substructure VL53L1_optical_centre_t which contains the two coordinates
(expressed in the SPAD number):
• x_centre
• y_centre
The host can use these two coordinates to better align the ROI to the optical center.
DocID031478 Rev 1 15/28
28
Ranging API function descriptions UM2356
As described in the datasheet, the user can select two modes for a VDDIO value of 1V8 or
2V8 modes.
The selection of the mode is made directly in the code though a compilation key called
USE_I2C_2V8 k.
If this compilation key is defined, the system will go into 2V8 mode, otherwise, it will be kept in the default 1V8 mode.
The VL53L1_RangingMeasurementData_t structure is composed of:
• TimeStamp : not implemented, please ignore it.
• StreamCount : this 8-bit integer counter increments at each range. The value starts at
0, increments to 255, and then increments from 128 to 255.
• RangingQualityLevel : not implemented, please ignore it.
• SignalRateRtnMegaCps : this value is the return signal rate in MegaCountPer Second
(MCPS). It is a 16.16 fix point value.To obtain a real value it should be divided by
65536.
• AmbientRateRtnMegaCps : this value is the return ambient rate (in MCPS). It is a
16.16 fix point value, which is effectively a measure of the infrared light. To obtain a real value it should be divided by 65536.
• EffectiveSpadRtnCount : this 16 bit integer returns the effective SPAD count for the current ranging. To obtain a real value it should be divided by 256.
• SigmaMilliMeter : this 16.16 fix point value is an estimation of the standard deviation of the current ranging, expressed in millimeters. To obtain a real value it should be divided by 65536.
• RangeMilliMeter : this 16 bit integer give the range distance in millimeters.
• RangeFractionalPart : not implemented, please ignore it.
• RangeStatus : this 8 bit integer gives the range status for the current measurement. A
value of 0 means the ranging is valid (refer to Table 4 ).
16/28 DocID031478 Rev 1
UM2356 Ranging API function descriptions
Value
0
1
2
4
5
7
8
14
Table 4. Range status
RangeStatus string Comment
VL53L1_RANGESTATUS_RANGE_VALID Ranging measurement is valid
VL53L1_RANGESTATUS_SIGMA_FAIL
Raised if sigma estimator check is above the internal defined threshold
VL53L1_RANGESTATUS_SIGNAL_FAIL
Raised if signal value is below the internal defined threshold
VL53L1_RANGESTATUS_OUTOFBOUNDS_
FAIL
Raised when phase is out of bounds
VL53L1_RANGESTATUS_HARDWARE_FAIL Raised in case of HW or VCSEL failure
VL53L1_RANGESTATUS_WRAP_TARGET_
FAIL
Wrapped target, not matching phases
VL53L1_RANGESTATUS_PROCESSING_
FAIL
Internal algorithm underflow or overflow
VL53L1_RANGESTATUS_RANGE_INVALID The reported range is invalid
DocID031478 Rev 1 17/28
28
Calibration functions UM2356
To benefit from the full performance of the device, the VL53L1X driver includes calibration functions that should be run once at the customer production line.
Calibration procedures have to be run to compensate the part-to-part parameters and the presence of the cover glass that may affect the device performance.
Calibration data stored in the host have to be loaded into theVL53L1X at each startup using a dedicated driver function.
Three calibrations are needed: RefSPAD, offset, and crosstalk.
The order the calibration functions are called is important: RefSPAD should be called first, offset second, and crosstalk third.
The three calibration functions can be done sequentially one after another, or individually.
When run individually, the previous step data have to be loaded before running the current calibration.
The number of SPADs is calibrated during the final module test at ST. This part-to-part value is stored in the NVM and automatically loaded into the device during boot.
This calibration allows adjustment of the number of SPADs to optimize the device dynamic.
However, adding a cover glass on top of the module may affect this calibration. We recommend that the customer performs this calibration again in the final product application.
The same algorithm running at FMT is applied when this function is called. The algorithm searches through the three possible types of SPAD:
1.
Non attenuated SPAD
2. SPAD attenuated by a factor of 5
3. SPAD attenuated by a factor of 10
The number and type of SPAD is selected to avoid internal signal saturation.
Note:
A dedicated function is available for this operation:
VL53L1_PerformRefSpadManagement(&VL53L1Dev)
This function must be called first in the calibration procedure.
18/28 DocID031478 Rev 1
UM2356 Calibration functions
3.1.3
3.1.4
The user has to ensure that there are no targets closer than 5 cm from the sensor during the calibration.
It is better to perform this calibration in low IR light conditions (indoor).
The time to perform this calibration is only few milliseconds.
The
VL53L1_PerformRefSpadManagement function has to be called after the
VL53L1_DataInit()
and
VL53L1_StaticInit() functions are called. Refer to
Figure 4: VL53L1X calibration flow
.
When the calibration function is called, the RefSPAD calibration is performed and the new
RefSPAD parameters are applied at the end.
Getting RefSPAD calibration results
The function
VL53L1_GetCalibrationData()
allows all calibration data to be obtained.
The returned structure VL53L1_CalibrationData_t also contains a substructure called
VL53L1_customer_nvm_managed_t which contains the eight RefSPAD calibration parameters:
• ref_spad_man__num_requested_ref_spads : this value is between 5 and 44. It gives the number of SPADs selected.
• ref_spad_man__ref_location : this value can be
– non attenuated SPAD
– SPAD attenuated by a factor of 5
– SPAD attenuated by a factor of 10
• Six additional parameters gives the good SPAD maps for the location selected.
After factory calibration, these calibration data have to be stored in the host memory and loaded at each device start up to avoid redoing the calibration. Either the user stores the entire structure VL53L1_CalibrationData_t or stores the eight parameters (to save memory space).
Setting RefSPAD calibration data
At each start up, after a hard reset, the user can load the RefSPAD calibration data from the host memory. The
VL53L1_SetCalibrationData()
has to be called after the
VL53L1_DataInit()
and
VL53L1_StaticInit() functions are called. Refer to
Figure 5: VL53L1X ranging flow
If the user has optimized the calibration data storage during the calibration, it is recommended to get the entire calibration structure by calling
VL53L1_GetCalibrationData()
, modifying the eight parameters described in
Section 3.1.3: Getting RefSPAD calibration results , and calling
VL53L1_SetCalibrationData()
.
DocID031478 Rev 1 19/28
28
Calibration functions UM2356
Soldering the device on the customer board or adding a cover glass can introduce an offset in the ranging distance. This part-to-part offset has to be measured and compensated during the offset calibration.
Note:
A dedicated function is available for this operation:
VL53L1_PerformOffsetSimpleCalibration(&VL53L1Dev,
CalDistanceMilliMeter)
The argument of the function is the offset calibration distance in millimeters.
Offset calibration has to be performed before crosstalk calibration and after RefSPAD optimization is done (calibration done or RefSPAD parameters loaded).
3.2.3
The customer has to use a calibrated chart, placed at a given distance
(
CalDistanceMilliMeter
) to perform the offset calibration.
Details of the recommended setup are given in
Chart
Table 5. Offset calibration set up
Chart distance
(
CalDistanceMilliMeter)
Gray target
(17 % reflectance at 940 nm)
Recommended value: 140 mm
Ambient conditions
Dark
(no IR contribution)
When the calibration function is called, the offset calibration is performed and the offset correction is applied at the end.
Getting offset calibration results
The function
VL53L1_GetCalibrationData()
allows all calibration data to be obtained.
The returned structure VL53L1_CalibrationData_t also contains a substructure called
VL53L1_customer_nvm_managed_t which contains the main offset calibration result: algo__part_to_part_range_offset_mm.
The customer can load the offset calibration data after the
VL53L1_DataInit()
and
VL53L1_StaticInit() functions are called, by using
VL53L1_SetCalibrationData()
.
However, it is better to call
VL53L1_GetCalibrationData()
, modify the parameter described in
Section 3.2.3: Getting offset calibration results
(algo__part_to_part_range_offset_mm) and call
VL53L1_SetCalibrationData()
.
20/28 DocID031478 Rev 1
UM2356 Calibration functions
Crosstalk (xtalk) is defined as the amount of the return signal received on the sensing array which is due to VCSEL light reflection inside the protective window (cover glass) added on top of the module for aesthetic and protective reasons.
Depending on the cover glass quality, the amount of the return signal can be significant and can affect the sensor performance. The VL53L1X has a built-in correction that allows for this crosstalk phenomenon to be compensated.
Crosstalk calibration is used to estimate the amount of correction needed to compensate the effect of a cover glass added on top of the module.
3.3.1 Cross calibration function
Note:
A dedicated function is available for this operation:
VL53L1_PerformSingleTargetXTalkCalibration(&VL53L1Dev,
XtalkCalDistance);
One argument of the function is the crosstalk calibration distance in millimeters.
This function must be called in third place in the calibration flow, after the offset compensation is done (calibration done or offset parameters loaded).
3.3.2 Cross calibration procedure
The cross talk calibration should be conducted in a dark environment, with no IR contribution.
When the calibration function is called, the crosstalk calibration is performed and the crosstalk correction is applied at the end.
Chart
Table 6. Crosstalk calibration set up
Chart distance
(
XtalkCalDistance )
Gray target
(17 % reflectance at 940 nm)
As defined in
Section 3.3.3: Crosstalk calibration distance characterization
Ambient conditions
Dark
(no IR contribution)
The crosstalk calibration distance needs to be characterized by the user, as it depends on the system environment, mainly the cover glass material and optical properties, and the air gap value (distance between the sensor and the cover glass).
Figure 8: VL53L1X crosstalk calibration distance definition shows the crosstalk effect on the
ranging curve. From a given distance, the effect of the crosstalk is predominant, and the sensor starts to under-range.
DocID031478 Rev 1 21/28
28
Calibration functions
3.3.4
3.3.5
UM2356
Figure 8. VL53L1X crosstalk calibration distance definition
ZĂŶŐŝŶŐ
ĚŝƐƚĂŶĐĞ
/ĚĞĂů
ZĂŶŐŝŶŐĐƵƌǀĞ
ZĂŶŐŝŶŐĐƵƌǀĞ
ǁŝƚŚyƚĂůŬĐŽŵƉĞŶƐĂƚĞĚ
yƚĂůŬ
ĐĂůŝďƌĂƚŝŽŶ
ĚŝƐƚĂŶĐĞ
ZĂŶŐŝŶŐĐƵƌǀĞ
ǁŝƚŚyƚĂůŬĞĨĨĞĐƚ
dĂƌŐĞƚ
ĚŝƐƚĂŶĐĞ
The crosstalk calibration distance corresponds to the maximum ranging distance achievable reported by the sensor when the cover glass is present (see
This maximum ranging distance is one argument of the crosstalk calibration driver function.
The ranging curve with crosstalk corrected is the ranging result when the crosstalk compensation is applied (when crosstalk calibration is completed or after crosstalk calibration data are loaded).
Getting crosstalk calibration results
The function
VL53L1_GetCalibrationData()
allows all calibration data to be obtained.
The returned structure VL53L1_CalibrationData_t also contains a substructure called
VL53L1_customer_nvm_managed_t which contains the crosstalk calibration result: algo__crosstalk_compensation_plane_offset_kcps.
Setting crosstalk calibration data
The customer can load the crosstalk calibration data after the
VL53L1_DataInit()
and
VL53L1_StaticInit() functions are called, by using
VL53L1_SetCalibrationData()
It is recommended to call
VL53L1_GetCalibrationData()
, modify the algo__crosstalk_compensation_plane_offset_kcps parameter in the
VL53L1_customer_nvm_managed_t substructure, and then call
VL53L1_SetCalibrationData() to apply the crosstalk compensation.
22/28 DocID031478 Rev 1
UM2356
3.3.6
Note:
Calibration functions
Enable/Disable crosstalk compensation
The function to call to enable or disable the crosstalk compensation is:
VL53L1_SetXTalkCompensationEnable().
VL53L1_SetXTalkCompensationEnable(&VL53L1Dev, 0);
// disables the crosstalk compensation.
V53L1_SetXTalkCompensationEnable(&VL53L1Dev, 1);
// enables the crosstalk compensation.
This function does not perform any crosstalk calibration or data loading, it just enables the crosstalk compensation. It has to be called before starting ranging, with the optional function calls.
DocID031478 Rev 1 23/28
28
Driver errors and warnings
4 Driver errors and warnings
UM2356
The driver error is reported when any driver function is called. Possible values for driver errors are described in
Please note that warnings exist to inform the user that some parameters are not optimized.
The warnings are not blocking points for the host.
Table 7. Bare driver errors and warnings descriptions
-6
-7
-8
-10
-14
-16
Error value
0
-1
-4
-5
-22
-23
-24
-28
-29
-30
API error string Occurrence
VL53L1_ERROR_NONE
VL53L1_ERROR_CALIBRATION_WARNING
VL53L1_ERROR_INVALID_PARAMS
VL53L1_ERROR_NOT_SUPPORTED
VL53L1_ERROR_RANGE_ERROR
VL53L1_ERROR_TIME_OUT
VL53L1_ERROR_MODE_NOT_SUPPORTED
VL53L1_ERROR_CALIBRATION_WARNING
VL53L1_ERROR_INVALID_COMMAND
VL53L1_ERROR_REF_SPAD_INIT
VL53L1_ERROR_XTALK_EXTRACTION_FAIL
VL53L1_ERROR_XTALK_EXTRACTION_SIGMA_
LIMIT_FAIL
VL53L1_ERROR_OFFSET_CAL_NO_SAMPLE_
FAIL
VL53L1_WARNING_REF_SPAD_CHAR_NOT_
ENOUGH_SPADS
TOO_HIGH
VL53L1_WARNING_REF_SPAD_CHAR_RATE_
VL53L1_WARNING_REF_SPAD_CHAR_RATE_
TOO_LOW
No error
Invalid calibration data
Invalid parameter is set in a function
Requested parameter is not supported in the programmed configuration
Interrupt status is incorrect
Ranging is aborted due to timeout
Requested mode is not supported
Supplied buffer is larger than I2C supports
Command is invalid in current mode
An error occurred during reference SPAD calibration
Thrown when crosstalk calibration function has no successful samples to compute the crosstalk. In this case there is not enough information to generate new crosstalk parameter information. The function will exit and leave the current crosstalk parameters unaltered.
Thrown when crosstalk calibration function has found that the sigma estimate is above the maximal limit allowed. In this case the crosstalk sample is too noisy for measurement. The function will exit and leave the current crosstalk parameters unaltered.
Thrown when offset calibration function has found no valid ranging.
Thrown if there are less than five good SPADs available. Ensure calibration setup is in line with ST recommendations.
Thrown if the final reference rate is greater than the upper reference rate limit - default is 40 Mcps. Ensure calibration setup is in line with ST recommendations.
Thrown if the final reference rate is less than the lower reference rate limit - default is 10 Mcps. Ensure calibration setup is in line with ST recommendations.
24/28 DocID031478 Rev 1
UM2356 Driver errors and warnings
Error value
-31
-32
-33
-34
-41
Table 7. Bare driver errors and warnings descriptions (continued)
API error string Occurrence
VL53L1_WARNING_OFFSET_CAL_MISSING_
SAMPLES
VL53L1_WARNING_OFFSET_CAL_SIGMA_
TOO_HIGH
VL53L1_WARNING_OFFSET_CAL_RATE_
TOO_HIGH
VL53L1_WARNING_OFFSET_CAL_SPAD_
COUNT_TOO_LOW
VL53L1_ERROR_NOT_IMPLEMENTED
Thrown if there is less than the requested number of valid samples. Ensure offset calibration setup is in line with ST recommendations.
Thrown if the offset calibration range sigma estimate is too high. Ensure offset calibration setup is in line with ST recommendations.
Thrown when signal rate is greater than a limit and sensor is saturating. Ensure offset calibration setup is in line with ST recommendations.
Thrown when not enough SPADS can be used.
Ensure offset calibration setup is in line with ST recommendations.
Function called is not implemented
DocID031478 Rev 1 25/28
28
Acronyms and abbreviations
5 Acronyms and abbreviations
Acronym/ abbreviation
Table 8. Acronyms and abbreviations
Definition
I2C
NVM
SPAD
VCSEL
FMT
API
Inter-integrated circuit (serial bus)
Non volatile memory
Single photon avalanche diode
Vertical cavity surface emitting laser
Final Module Test
Application Programming Interface
UM2356
26/28 DocID031478 Rev 1
UM2356
Date
07-Mar-2018
Table 9. Document revision history
Revision Changes
1 Initial release
Revision history
DocID031478 Rev 1 27/28
28
UM2356
IMPORTANT NOTICE – PLEASE READ CAREFULLY
STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, enhancements, modifications, and improvements to ST products and/or to this document at any time without notice. Purchasers should obtain the latest relevant information on
ST products before placing orders. ST products are sold pursuant to ST’s terms and conditions of sale in place at the time of order acknowledgement.
Purchasers are solely responsible for the choice, selection, and use of ST products and ST assumes no liability for application assistance or the design of Purchasers’ products.
No license, express or implied, to any intellectual property right is granted by ST herein.
Resale of ST products with provisions different from the information set forth herein shall void any warranty granted by ST for such product.
ST and the ST logo are trademarks of ST. All other product or service names are the property of their respective owners.
Information in this document supersedes and replaces information previously supplied in any prior versions of this document.
© 2018 STMicroelectronics – All rights reserved
28/28 DocID031478 Rev 1