Trane IC-IH 039, IC-IH 059 Installation Operation & Maintenance
PDF
Documento
Anúncio
Anúncio
Installation Operation Maintenance Airfinity Rooftop units Models IC - Cooling only IH - Heat pump 20 - 135 kW R410A Refrigerant November 2020 RT-SVX056D-GB Confidential and proprietary Trane information Original instructions Table of Contents General Information .......................................................................................... 4 Foreword.................................................................................................... 4 Warnings and Cautions............................................................................. 4 Safety Recommendations......................................................................... 4 Reception................................................................................................... 4 Loose Parts Inventory................................................................................ 4 Warranty..................................................................................................... 4 Refrigerant................................................................................................. 4 Maintenance Contract............................................................................... 5 Storage....................................................................................................... 5 Training...................................................................................................... 5 Unit Model Number Description....................................................................... 6 IC - IH General Data............................................................................................ 8 Unit Operating Principle................................................................................... 18 Installation......................................................................................................... 19 Reception of Units .................................................................................. 19 Roof Curb Installation............................................................................. 19 Installing the Unit.................................................................................... 20 Unit overall view...................................................................................... 21 Dimensions/Weights/Clearances............................................................ 22 Connection of Duct Network.................................................................. 22 Condensate Drain Piping........................................................................ 22 Filter Installation...................................................................................... 23 Supply plug fan airflow adjustment...................................................... 23 Supply fan Airflow measurement option.............................................. 24 Gas Pipework Installation....................................................................... 24 Smoke outlet features............................................................................. 25 General Electrical Recommendations.................................................... 25 Installer-Supplied Components.............................................................. 25 Electrical Connections............................................................................. 26 Operating Map.................................................................................................. 27 Cooling mode.......................................................................................... 27 Heating mode.......................................................................................... 27 ERC Cooling mode.................................................................................. 28 ERC Heating mode.................................................................................. 28 2 © 2020 Trane RT-SVX056D-GB Table of Contents Options.............................................................................................................. 29 Fresh air hood and grill installation....................................................... 29 Building Pressurization Control.............................................................. 29 Hot Water Coil (HWC).............................................................................. 31 Electric Heater.......................................................................................... 31 Heat Recovery Module............................................................................ 32 Burner module......................................................................................... 36 Energy Recovery Circuit (ERC)............................................................... 36 Assembly procedure of fan block.......................................................... 36 ERC fan module installation................................................................... 37 Controls............................................................................................................. 38 CH536 + module extension..................................................................... 38 Control Hardware Modules.................................................................... 38 Service Terminal....................................................................................... 38 CO2 sensor............................................................................................... 39 CO2 sensor maintenance........................................................................ 39 Fire Thermostat ....................................................................................... 39 Clogged Filter Detector .......................................................................... 39 Smoke Detector ...................................................................................... 39 Other accessories available.................................................................... 39 Alarm and Warnings................................................................................ 39 Customer option module................................................................................. 40 Customer option module........................................................................ 40 Operation with a conventional thermostat........................................... 40 Economizer control................................................................................. 41 Operation........................................................................................................... 42 Test Procedures....................................................................................... 42 Gas Burner first start............................................................................... 43 ERC first start and contro........................................................................ 43 Maintenance...................................................................................................... 44 End-user Routine Maintenance ............................................................. 44 Service Technician Maintenance ............................................................ 44 Troubleshooting Alarm and Warnings .................................................. 44 Recommended service routine frequencies................................................... 45 Maintenance routine........................................................................................ 46 Additional services........................................................................................... 47 RT-SVX056D-GB 3 General information Foreword These instructions are given as a guide to good practice in the installation, start-up, operation, and maintenance by the user, of Trane Airfinity rooftop units. They do not contain full service procedures necessary for the continued successful operation of this equipment. The services of a qualified technician should be employed through the medium of a maintenance contract with a reputable service company. Read this manual thoroughly before unit start-up. Units are assembled, pressure tested, dehydrated, charged and tested in accordance with factory standard before shipment. Warnings and Cautions Warnings and Cautions appear at appropriate sections throughout this manual. Your personal safety and the proper operation of this machine require that you follow them carefully. The constructor assumes no liability for installations or servicing performed by unqualified personnel. WARNING! Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION! Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices or for equipment or property-damage-only accidents. Reception On arrival, inspect the unit before signing the delivery note. Specify any visible damage on the delivery note, and send a registered letter of protest to the last carrier of the goods within 7 days of delivery. Notify the local TRANE sales office at the same time. The delivery note must be clearly signed and countersigned by the driver. Any concealed damage shall be notified by a registered letter of protest to the last carrier of the goods within 7 days of delivery. Notify the local TRANE sales office at the same time. Important notice: No shipping claims will be accepted by TRANE if the above mentioned procedure is not respected. For more information, refer to the general sales conditions of your local TRANE sales office. Note: Unit inspection in France. Delay to send registered letter in case of visible and concealed damage is only 72 hours. Loose Parts Inventory Check all the accessories and loose parts that are shipped with the unit against the shipping list. Included in these items will be the all kind of sensors, thermostat and electrical diagrams, service literature, which are placed inside the control panel and/or indoor section for shipment. Warranty 1. The maximum allowable pressures for system leak testing on low and high pressure side are given in the chapter “Installation”. Insure to do not exceed test pressure by using appropriate device. Warranty is based on the general terms and conditions of the manufacturer. The warranty is void if the equipment is repaired or modified without the written approval of the manufacturer, if the operating limits are exceeded or if the control system or the electrical wiring is modified. Damage due to misuse, lack of maintenance or failure to comply with the manufacturer’s instructions or recommendations is not covered by the warranty obligation. If the user does not conform to the rules of this manual, it may entail cancellation of warranty and liabilities by the manufacturer. 2. Disconnect the main power supply before any servicing on the unit. Refrigerant 3. Service work on the refrigeration system and the electrical system should be carried out only by qualified and experienced personnel. 4. To avoid any risk, it is recommended to place the unit on an area with restricted access. Safety Recommendations To avoid death, injury, equipment or property damage, the following recommendations should be observed during maintenance and service visits: 4 Consult the addendum to Manuals for units with refrigerant, for conformity to the Pressure Equipment Directive (PED) 97/23/EC and Machinery Directive 2006/42/EC. RT-SVX056D-GB General information Maintenance Contract It is strongly recommended that you sign a maintenance contract with your local Service Agency. This contract provides regular maintenance of your installation by a specialist in our equipment. Regular maintenance ensures that any malfunction is detected and corrected in good time and minimizes the possibility that serious damage will occur. Finally, regular maintenance ensures the maximum operating life of your equipment. We would remind you that failure to respect these installation and maintenance instructions may result in immediate cancellation of the warranty. Storage Take precautions to prevent condensate formation inside the unit’s electrical components and motors when: a. The unit is stored before it is installed; or, b. The unit is set on the roof curb and temporary auxiliary heat is provided in the building. Isolate all side panel service entrances and base pan openings (e.g., conduit holes, Supply Air and Return Air openings, and flue openings) to minimize ambient air from entering the unit until it is ready for start-up. Do not use the unit’s heater as temporary heat without completing the start-up procedures detailed under “Unit Start-Up”. • U nits charged with refrigerant should not be stored where temperatures exceed 68°C. • A t least every three months, attach a gauge and manually check the pressure in the refrigerant circuit. • If the refrigerant pressure is below 13 bar at 20°C (or 10 bar at 10°C), call a qualified service organization or Trane Sales Office. The Trane Company will not assume responsibility for equipment damage resulting from accumulation of condensate on the unit electrical components. Training To assist you in obtaining the best use of it and maintaining it in perfect operating condition over a long period of time, the manufacturer has at your disposal a refrigeration and air conditioning service school. The principal aim of this is to give operators and technicians a better knowledge of the equipment they are using, or that is under their charge. Emphasis is particularly given to the importance of periodic checks on the unit operating parameters as well as on preventive maintenance, which reduces the cost of owning the unit by avoiding serious and costly breakdown. RT-SVX056D-GB 5 Unit Model Number Description Digit 1 - Manufacturing location E = Epinal France Digit 2 - Unit Model I = Airfinity Digit 3 - Unit type C = Cooling only H = Reversible Heat pump Digit 4-5-6 Unit Nominal Capacity 021 = 20 kW Heat Pump only 031 = 30 kW Heat Pump only 038 = 38 kW 039 = 39 kW 040 = 40 kW 041 = 40 kW Heat Pump only 048 = 48 kW Cooling only 049 = 49 kW 050 = 50 kW 051 = 50 kW Heat Pump only 058 = 58 kW Cooling only 059 = 59 kW 060 = 60 kW 061 = 60 kW Heat Pump only 063 = 63 kW Cooling only 064 = 64 kW 065 = 65 kW 071 = 64 kW Heat Pump only 074 = 74 kW 075 = 75 kW 084 = 84 kW 085 = 85 kW 100 = 100 kW 110 = 110 kW 130 = 130 kW Digit 7 - Efficiency level A = Adaptive Frequency Drive S = Standard efficiency Digit 8 - Refrigerant A = R410A Factory full refrigerant charge 8 = R410A Factory refrigerant pre charge Digit 9 - Unit voltage E = 400 V - 3 Ph - 50 Hz Digit 10 - Design Sequence Digit 11 - Design Sequence Digit 12 - Auxiliary Heat X = Without W = Hot water coil E = Electric heater M = Modulating burner Digit 13 - Gas type X = Without 1 = Propane gas 2 = Natural gas (G20) 3 = Natural gas (G25) 6 Digit 14 - Airflow configuration D = Down Supply & Down Return H = Horizontal Supply & Horizontal Return I = Down Supply & Horizontal Return J = Horizontal Supply & Down Return Digit 15 - Available static pressure 1 = Standard External Static Pressure 2 = High External Static Pressure Digit 16 - Operating map (cooling mode) A = Standard ambient L = Low ambient Digit 17 - Free cooling (Economizer) A = Temperature control B = Enthalpy control X = Without (full recirculation) Digit 18 - Heat Recovery Module X = Without R = Configured for Rotary Wheel B = Configured for Rotary wheel high airflow T = Energy Recovery Circuit fan AC U = Energy Recovery Circuit fan EC Digit 19 - Dehumidification X = Without A = Dehumidification control Digit 20 - Outdoor coil treatment B = Without E = With Digit 21 - Indoor coil treatment 1 = Without 2 = With Digit 22 - Filtration A = G4 (50 mm) filters B = G4 (50 mm) + F7 (100 mm) filters C = G4 (50 mm) + F9 (100 mm) filters D = F5 (50 mm) + F7 (100 mm) filters Digit 23 - Temperature Zone sensor X = Without A = Duct-mounted zone sensor B = Wall mounted zone sensor Digit 24 - Room User Interface X = Without A = Wall-mounted interface THP05 B = Conventional thermostat Digit 25 - C02 sensor X = Without 1 = CO2 sensor duct-mounted 2 = CO2 sensor wall-mounted Digit 26 - Smoke detector X = Without 1 = With RT-SVX056D-GB Unit Model Number Description Digit 27 - Airflow Measurement X = Without A = Airflow measurement and display Digit 38 - Service User Interface X = Without 1 = Service terminal PGD (supplied loose) Digit 28 - Dirty filter detection X = Without 1 = With Digit 39 - Fire Thermostat X = Without 1 = With Digit 29 - Network protection relay X = Phase reversal protection A = Phase reversal and asymmetry protection Digit 40/41/42/43 - Not used Digit 30 - Literature Language B = Spanish C = German D = English E = French J = Italian P = Polish V = Portuguese Digit 44 - Condenser Guard grill X = Without A = With condenser guard grill Digit 45 - Export Packaging X = Without A = With export packaging Digit 46 - Special design X = Standard S = Special design Digit 31 - Building Pressurization Control X = Without 1 = Barometric relief damper 2 = Exhaust Fan AC 3 = Exhaust Fan EC 4 = Configured for Return roofcurb Digit 32 - not used Digit 33 - External Customer Input/Output X = Without 1 = With Digit 34 - Multi-Rooftop Control X = Without C = With Tracer Concierge Comfort T = With Tracer Concierge Comfort with Display (Recommended) Digit 35 - Communication interface X = Without 1 = ModBus communication interface 2 = LonTalk® communications interface 3 = BACnet (MSTP) Digit 36 - RFI filter X = RFI filter 1 = High performance Digit 37 - Compressor Starter Type X = Across the line A = Soft starter RT-SVX056D-GB 7 IC - IH General Data Table 1 – Single compressor circuit IC - IH 039 IC - IH 049 IC - IH 059 IC - IH 064 IC - IH 074 IC - IH 084 Cooling Mode Net Cooling Capacity (1) kW 41 51 57 65 81 87 Total Power Input (1) kW 13.0 16.9 20.3 24.8 26.5 30.5 kW 37.9 47.4 53.5 62.8 70.7 78.4 kWm 11.7 14.8 17.6 20.4 20.6 23.7 Heating Mode Net Heating Capacity (1) Power Input (1) Electric Heater Number of capacity step Nb 2 2 2 2 2 2 Capacity Steps (1) kW 12,5 / 12,5 12,5 / 12,5 12,5 / 25 12,5 / 25 12.5 / 25 12.5 / 25 400 / 3 /50 Electrical Data (2) (3) Main Power Supply V/Ph/Hz 400 / 3 /50 400 / 3 /50 400 / 3 /50 400 / 3 /50 400 / 3 /50 Unit Max Amps A 37 43 52 61 66 73 Unit Start Up Amps (without soft starter) A 124 154 171 183 199 238 Unit Start Up Amps (with soft starter) A 92 109 123 132 144 169 Maximum Short Circuit rating for 0,3 sec kA 15 15 15 15 15 15 Sirco 125A Sirco 125A Sirco 125A Sirco 125A Sirco 125A Sirco 125A 50 50 50 50 50 50 Sirco 250A Sirco 250A Sirco 250A Sirco 250A Sirco 250A Sirco 250A mm2 150 150 150 150 150 150 Electric Heater A 36.1 36.1 54.1 54.1 54.1 54.1 Outdoor fan: Low Ambient A 3.6 3.6 3.6 3.6 1.6 1.6 Indoor fan: Oversized A 0.0 0.0 0.0 0.0 0.0 7.4 Exhaust Fan (70pa) A 0.6 0.6 0.6 0.6 1.2 1.2 Exhaust Fan (150pa) A 1.0 1.0 1.0 1.0 2.0 2.0 Return Roofcurb A 5.3 5.3 5.3 9.0 10.6 10.6 Heat Recovery (not included current for oversized fan) A 7.5 7.5 7.5 7.5 7.5 7.5 Gas burner (staged) A 0.4 0.4 0.5 0.5 0.5 0.5 Gas burner (modulating) A 0.3 0.3 0.4 0.4 0.5 0.5 ERC (compressor + exhaust fans) A 7.9 7.9 7.9 7.9 11.7 11.7 Frame1 Frame1 Frame1 Frame1 Frame2 Frame2 2 Disconnect switch std unit Max power cable cross section (Standard unit) mm2 Disconnect switch unit with option (heat recovery, Exhaust fan, Return Fan,Auxiliary heat) Max power cable cross section (unit with option-Heat recovery, Exhaust fan, Return fan, Auxiliary heat) Electrical data of options (2) (3) Frame Frame Compressor Number of Circuits # 2 2 2 2 2 Number of Compressor per Circuits # 1 1 1 1 1 1 Scroll Scroll Scroll Scroll Scroll Scroll SH184-4 Type Model ZP83KCE TFD 522 ZP104KCE TFD 455 ZP122KCE TFD 455 ZP143KCE TFD 455 SH161-4 Max Amps per Compressor A 14.3 17.1 20.1 24.5 25.1 32.2 Locked Rotor Amps per Compressor A 101.0 128.0 139.0 146.0 158.0 197.0 Oil & Refrigerant Oil quantity per compressors OIL58E/OIL57E (6) l 1.8 2.5 2.5 2.5 3.3 3.6 Oil quantity ckt1/ckt2 OIL58E/OIL57E (6) l 1.8/1.8 2.5/2.5 2.5/2.5 2.5/2.5 3.3/3.3 3.6/3.6 Refrigerant charge per circuit (ckt1/ckt2) IH kg 8.0/8.0 8.5/8.5 8.5/8.5 8.5/8.5 N/A N/A Refrigerant charge per circuit (ckt1/ckt2) IC kg 6.0/6.0 6.0/6.0 8.0/8.0 8.0/8.0 11.0/11.0 11.0/11.0 Fins & Tubes Fins & Tubes Outdoor Coil Type Fins & Tubes Fins & Tubes Fins & Tubes Fins & Tubes 5/16" 5/16" 5/16" 5/16" 5/16" 5/16" Face Area Inches m2 2.046 2.046 2.046 2.046 2.502 2.502 Rows/Fin Series #/FPF 2 or 3 / 192 3 / 192 3 / 192 3 / 192 3 / 192 3 / 192 48.0 48.0 48.0 48.0 48.0 48.0 Tube Size Number of Tubes in the height Indoor Coil Type Fins & Tubes Fins & Tubes Fins & Tubes Fins & Tubes Fins & Tubes Fins & Tubes 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" Face Area Inches m2 1.8 1.8 1.8 1.8 2.4 2.4 Rows/Fin Series #/FPF 3 / 168 3 / 168 3 / 168 3 / 168 4 / 168 4 / 168 48.0 48.0 48.0 48.0 48.0 48.0 35.0 35.0 35.0 35.0 35.0 35.0 Fins&Tubes-HWC01 Fins&Tubes-HWC02 Tube Size Number of Tubes in the height Drain Connection No./Size mm Hot Water Coil Type Fins&Tubes-HWC01 Fins&Tubes-HWC01 Fins&Tubes-HWC01 Fins&Tubes-HWC02 3/8'' 3/8'' 3/8'' 3/8'' 3/8'' 3/8'' Face Area Inches m2 0.769 0.769 0.769 0.769 0.769 1.087 Rows/Fin Series #/FPF 2 / 144 2 / 144 2 / 144 2 / 144 2 / 144 2/144 25.0 25.0 25.0 25.0 25.0 25.0 Tube Size Number of Tubes in the height 8 RT-SVX056D-GB IC - IH General Data Table 1 – Single compressor circuit (continued) IC - IH 039 IC - IH 049 IC - IH 059 IC - IH 064 IC - IH 074 IC - IH 084 Indoor Fan Standard Type Model Minimum Airflow Nominal Airflow Maximal Airflow Number Diameter m3/h m3/h Motor Max Amps per fan Motor RPM at nominal flow rate (Eurovent condition) Available Static Pressure at nominal flow rate Plug Fans Plug Fans Plug Fans Plug Fans Plug Fans K3G500PA2371 K3G500PB3301 K3G500PB3301 K3G500PA2371 K3G500PA2371 6560.0 8000.0 8880.0 10300.0 12400.0 13360.0 8200.0 10000.0 11100.0 12400.0 15500.0 16700.0 10660.0 13000.0 14430.0 16120.0 20150.0 21710.0 # 1.0 1.0 1.0 1.0 2.0 2.0 mm 500.0 500.0 500.0 500.0 500.0 500.0 m3/h Drive Type Motor Power (Eurovent condition) Plug Fans K3G500PA2371 EC Motors EC Motors EC Motors EC Motors EC Motors EC Motors kW 0.9 1.4 2.0 2.6 2.1 2.6 A 5.3 5.3 9.0 9.0 5.3 5.3 RPM 1247.5 1502.3 1675.8 1851.0 1321.0 1425.8 Pa 250.0 250.0 250.0 250.0 250.0 250.0 Oversized Type Model Minimum Airflow Nominal Airflow Maximal Airflow Number Diameter m3/h m3/h Plug Fans Plug Fans Plug Fans Plug Fans Plug Fans Plug Fans K3G500PA2371 K3G500PA2371 K3G500PB3301 K3G500PB3301 K3G500PA2371 K3G500PB3301 6560 8000 8880 10300 12400 13360 m3/h 8200 10000 11100 12400 15500 16700 10660 13000 14430 16120 20150 21710 # 1 1 1 1 2 2 mm 500 500 500 500 500 500 Drive Type EC Motors EC Motors EC Motors EC Motors EC Motors EC Motors kW 0.9 1.4 2.0 2.6 2.2 2.7 A 5.3 5.3 9.0 9.0 5.3 9.0 RPM 1247.5 1502.3 1675.8 1851.0 1321.0 1422.8 Pa 500 500 500 500 500 500 Axial / Below / AC Axial / Below / AC Axial / Below / AC Axial / Below / AC Axial / Below / AC Axial / Below / AC A6D630AN0101 A6D630AN0101 A6D630AN0101 A6D630AN0101 A8D800A10105 A8D800A10105 9262.0 9258.7 9256.4 9252.3 14321.0 14317.8 # 1.0 1.0 1.0 1.0 1.0 1.0 Diameter mm 630.0 630.0 630.0 630.0 800.0 800.0 Motor Power per fan kW 0.6 0.6 0.6 0.6 0.89 0.89 A 1.2 1.2 1.2 1.2 2.2 2.2 rpm 910.0 910.0 910.0 910.0 686.0 686.0 Axial / Below / EC Axial / Below / EC Axial / Below / EC Axial / Below / EC Axial / Below / EC Axial / Below / EC A3G800AS3905 A3G800AS3905 A3G800AS3905 A3G800AS3905 A3G800AS3905 A3G800AS3905 9262.0 9258.7 9256.4 9252.3 14321.0 14317.8 # 1.0 1.0 1.0 1.0 1.0 1.0 Diameter mm 690.0 690.0 690.0 690.0 690.0 690.0 Motor Power per fan kW 1.95 1.95 1.95 1.95 1.95 1.95 A 3.0 3.0 3.0 3.0 3.0 3.0 rpm 910.0 910.0 910.0 910.0 686.0 686.0 Length mm 3010 3010 3010 3010 3890 3890 Width mm 2250 2250 2250 2250 2250 2250 Height mm 1565 1565 1565 1565 1585 1585 IC Operating Weight (Downflow Without Auxiliary Heat) kg 938 955 992 992 1280 1292 IC Shipping Weight (Downflow Without Auxiliary Heat) kg 994 1011 1048 1048 1340 1352 IH Operating Weight (Downflow Without Auxiliary Heat) kg 988 1005 1016 1016 1310 1322 IH Shipping Weight (Downflow Without Auxiliary Heat) kg 1044 1061 1072 1072 1370 1382 Hot Water Coil kg 48 48 48 48 59 59 Electric Heater kg 22 22 22 22 26 26 Gas Burner: staged kg 76 76 90 90 116 116 Gas Burner: modulating condensing kg 76 76 90 90 116 116 Energy Recovery Module kg 375 375 375 375 455 455 Exhaust Fan kg 24 24 24 24 39 39 Return Roofcurb Down kg 380 380 380 390 470 470 Return Roofcurb Horizontal kg 280 280 280 290 350 350 Downflow Adjustable Roofcurb kg 150 150 150 150 170 170 Multidirectional Roofcurb kg 190 190 190 190 220 220 Motor Power (Eurovent condition) Motor Max Amps per fan Motor RPM at nominal flow rate (Eurovent condition) Available Static Pressure at nominal flow rate Outdoor Fan Standard Ambient Type Model Nominal Airflow Number of fan / ckt Motor Max Amps per fan Motor RPM m3/h Low Ambient Type Model Nominal Airflow Number Motor Max Amps per fan Motor RPM m3/h Physical Data for Standard Unit (4) Options Extra Weight (4) RT-SVX056D-GB 9 IC - IH General Data Table 1 – Single compressor circuit (continued) IC - IH 039 Energy Recovery Module (ERM) IC - IH 049 IC - IH 059 IC - IH 064 IC - IH 074 IC - IH 084 m3/h m3/h 9500 9500 9500 9500 9500 9500 18000 18000 18000 18000 18000 18000 2500 2500 2500 2500 2500 2500 Exchanger Wheel Diameter mm 1200.0 1200.0 1200.0 1200.0 1200.0 1200.0 Exhaust Air Fan Diameter mm 400.0 400.0 400.0 400.0 400.0 400.0 Exhaust Air Fan Motor Power kW 3.4 3.4 3.4 3.4 3.4 3.4 Length x Width x Height mm 1750x1180x1510 1750x1180x1510 1750x1180x1510 1750x1180x1510 1750x1180x1510 250x1180x1530 kg 375.0 375.0 375.0 375.0 375.0 455.0 PCH045 PCH045 PCH065 PCH065 PCH080 PCH080 kW 8,50 - 42,0 8,50 - 42,0 12,40 - 65,0 12,40 - 65,0 16,40 - 82 16,40 - 82 kW 8,97 - 40,45 8,97 - 40,45 13,40 - 62,93 13,40 - 62,93 17,77 - 80,03 17,77 - 80,03 0,90 - 4,45 0,90 - 4,45 1,31 - 6,88 1,31 - 6,88 1,74 - 8,68 1,74 - 8,68 Max Exhaust Air @ ESP=400Pa Max Fresh Air @ Wheel PD=300Pa m3/h Min Wheel Airflow Weight Gas Burner Gas burner type - Premium modulating Thermal output (Hi) [Min-Max] Useful heat output [Min-Max] Gas Flow [Min-Max] (5) m3/h Flue gas emission Carbon monoxide - CO - (0% of O2) (5) Nitrogen oxides - NOx - (0% of O2) (5) CO2 max (5) ppm <5 <5 <5 <5 <5 <5 mg/KWh -ppm 19 - 33 19 - 33 22 - 39 22 - 39 18 - 32 18 - 32 9.1 9.1 9.1 9.1 9.1 9.1 % Gas Connection Pipe Diameter UNI/ISO 228/1-G 3/4" UNI/ISO 228/1-G 3/4" UNI/ISO 228/1-G 3/4" UNI/ISO 228/1-G 3/4" UNI/ISO 228/1-G 3/4" UNI/ISO 228/1-G 3/4" Energy Recovery Circuit (ERC) Cooling Mode Net Cooling Capacity (ERC only) kW 15.4 15.6 15.7 15.9 21.3 21.3 ERC Compressor Power Input kW 3.7 3.7 3.7 3.7 4.1 4.1 ERC Exhaust Fans Power Input kW 0.5 0.5 0.5 0.5 0.9 0.9 Total ERC Power Input kW 4.2 4.2 4.2 4.2 5 5 Net Cooling Capacity (ERC + IH standard) kW 61.3 72.1 77.8 85.5 107.9 114.6 Total Power Input (ERC + IH standard) kW 17.5 21.5 25.3 29.9 32.9 36.6 Net Heating Capacity (ERC only) kW 15.0 15 15 15 21 21.1 ERC Compressor Power Input kW 2.4 2.3 2.3 2.3 2.7 2.7 ERC Exhaust Fans Power Input kW 0.5 0.5 0.5 0.5 0.9 0.9 Total ERC Power Input kW 2.9 2.8 2.8 2.8 3.6 3.6 Net Heating Capacity (ERC + IH standard) kW 53.6 63.3 69.5 79.3 93.3 100.3 Total Power Input (ERC + IH standard) kW 14.2 17.2 19.9 22.8 24.4 27.2 Heating Mode Exhaust Fans & air management (7) Number of Exhaust Fans Exhaust Air Fans Type Exhaust Air Fans Model 1 1 1 1 2 2 Axial / AC Axial / AC Axial / AC Axial / AC Axial / AC Axial / AC W4D450CO1401 W4D450CO1401 W4D450CO1401 W4D450CO1401 W4D450CO1401 W4D450CO1401 mm 450 450 450 450 450 450 Minimum Fresh Air % 20 20 20 20 20 20 Maximum Recommended Fresh Air (compared to max airflow) % 50 41 37 33 51 47 Maximum Fresh Air (building pressurisation issues to be considered) % 100 100 100 100 100 100 Maximum Return Air Pressure Drop (without Return Roofcurb) Pa 100 100 100 100 100 100 Maximum Additional Air Pressure Drop (indoor coil) Pa 10 15 15 20 20 20 Exhaust Air Fans Diameter Oil & Refrigerant (7)(6) ERC Circuit Refrigerant Charge ERC Circuit Oil Quantity kg 2.3 2.3 2.3 2.3 2.7 2.7 l 1.24 1.24 1.24 1.24 1.24 1.24 mm 3010x2250x1565 3010x2250x1565 3010x2250x1565 3010x2250x1565 3890x2250x1585 3890x2250x1585 kg 1117 1134 1145 1145 1484 1496 Dimensiond and weights (7)(6) Length x Width x Height (ERC + IH standard) Weight (ERC + IH standard) (1) (2) (3) (4) (5) (6) Indicative performances. For detailled performances, consult order write up (OWU). U nder 400V/50Hz/3Ph. E lectrical & system data are indicative and subject to change without notice. Please refer to unit nameplate data. Indicative data. For details consult lifting and handling instructions in document package shipped with the unit. V alue referenced to Gas G20 - for other refer to burner IOM manual. O IL058E or OIL057E are European reference for POE oil and can be mixed in any proportion with OIL00078 or OIL00080 (same oil with US reference on compressor nameplate). (7) IH unit only. (8) The ERM data is only for Digit -18 R. 10 RT-SVX056D-GB IC - IH General Data Table 2 – Dual compressor circuit IC - IH 040 IC - IH 050 IC - IH 060 IC - IH 065 IC - IH 075 IC - IH 085 IC - IH 100 IC - IH 110 IC - IH 130 Cooling Mode Net Cooling Capacity (1) kW 44 54 61 72 82 88 104 113 133 Total Power Input (1) kW 13.5 17.3 20.0 23.8 27.2 30.1 34.3 40.4 50.7 Heating Mode Net Heating Capacity (1) Power Input (1) kW 38.5 48.8 54.9 63.7 72.3 77.0 92.2 103.8 125.3 kWm 11.8 15.0 17.1 19.4 21.2 23.2 26.9 31.3 39.0 Electric Heater Number of capacity step Nb 2 2 2 2 2 2 2 2 2 Capacity Steps (1) kW 12.5 / 12.5 12.5 / 12.5 12.5 / 25 12.5 / 25 12.5 / 25 12.5 / 25 25 / 37.5 25 / 37,5 25 / 37,5 400 / 3 /50 Electrical Data (2) (3) V/Ph/Hz 400 / 3 /50 400 / 3 /50 400 / 3 /50 400 / 3 /50 400 / 3 /50 400 / 3 /50 400 / 3 /50 400 / 3 /50 Unit Max Amps Main Power Supply A 42 48 54 63 73 72 92 104 123 Unit Start Up Amps (without soft starter) A 78 91 111 126 160 159 203 223 244 Unit Start Up Amps (with soft starter) A 63 73 87 100 124 123 158 174 193 Maximum Short Circuit rating for 0,3 sec kA 15 15 15 15 15 15 15 15 15 Sirco 125A Sirco 125A Sirco 125A Sirco 125A Sirco 125A Sirco 125A Sirco 125A Sirco 160A Sirco 160A 50 50 50 50 50 50 50 95 95 Sirco 250A Sirco 250A Sirco 250A Sirco 250A Sirco 250A Sirco 250A Sirco 315A Sirco 315A Sirco 315A mm2 150 150 150 150 150 150 240 240 240 90.2 Disconnect switch std unit Max power cable cross section (Standard unit) mm2 Disconnect switch unit with option (heat recovery, Exhaust fan, Return Fan, Auxiliary heat) Max power cable cross section (unit with option-Heat recovery, Exhaust fan, Return fan, Auxiliary heat) Electrical data of options (2) (3) Electric Heater A 36.1 36.1 54.1 54.1 54.1 54.1 90.2 90.2 Outdoor fan: Low Ambient A 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 0.0 Indoor fan: Oversized A 0.0 0.0 0.0 1.2 0.0 7.4 0.0 9.0 9.0 Exhaust Fan (70pa) A 0.6 0.6 0.6 0.6 1.2 1.2 1.2 1.2 1.2 Exhaust Fan (150pa) A 1.0 1.0 1.0 1.0 2.0 2.0 2.0 2.0 2.0 18.0 Return Roofcurb A 5.3 5.3 5.3 9.0 10.6 10.6 10.6 10.6 Heat Recovery (not included current for oversized fan) A 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 Gas burner (staged) A 0.4 0.4 0.5 0.5 0.5 0.5 0.5 0.5 0.5 Gas burner (modulating) A 0.3 0.3 0.4 0.4 0.5 0.5 0.6 0.6 0.6 ERC (compressor + exhaust fans) A 7.9 7.9 7.9 7.9 11.7 11.7 16.3 16.3 16.3 Frame1 Frame1 Frame1 Frame1 Frame2 Frame2 Frame3 Frame3 Frame3 Frame Frame Compressor Number of Circuits # 2 2 2 2 2 2 2 2 2 Number of Compressor per Circuits # 2 2 2 2 2 2 2 2 2 Scroll Scroll Type Model Scroll Scroll Scroll Scroll Scroll Scroll Scroll ZP42K5E TFD 422 ZP54K5E TFD 422 ZP61K5E TFD 422 ZP72KCE TFD 422 ZP83KCE TFD 422 ZP91KCE TFD 422 ZP104KCE TFD455 ZP122KCE TFD ZP143KCE TFD 455 455 Max Amps per Compressor A 6.9 8.4 9.7 12.1 14.3 13.9 17.1 20.1 24.5 Locked Rotor Amps per Compressor A 43.0 51.5 67.1 75.0 101.0 101.0 128.0 139.0 146.0 Oil quantity per compressors OIL58E/OIL57E (6) l 1.2 1.2 1.2 1.8 1.8 1.8 2.5 2.5 2.5 Oil quantity ckt1/ckt2 OIL58E/OIL57E (6) Oil & Refrigerant l 2.5/2.5 2.5/2.5 2.5/2.5 3.5/3.5 3.5/3.5 3.5/3.5 5.0/5.0 5.0/5.0 5.0/5.0 Refrigerant charge per circuit (ckt1/ckt2) IH kg 8.5 / 8.5 8.5 / 8.5 9.0 / 9.0 9.0 / 9.0 11.0 / 11.0 11.0 / 11.0 14.0 / 14.0 14.0 / 14.0 14.0 / 14.0 Refrigerant charge per circuit (ckt1/ckt2) IC kg 6.0/6.0 6.0/6.0 8.5/8.5 8.5/8.5 11.0/11.0 11.0/11.0 14.0/14.0 14.0/14.0 14.0/14.0 Fins & Tubes Fins & Tubes Outdoor Coil Type Fins & Tubes Fins & Tubes Fins & Tubes Fins & Tubes Fins & Tubes Fins & Tubes Fins & Tubes 5/16" 5/16" 5/16" 5/16" 5/16" 5/16" 5/16" 5/16" 5/16" Face Area Inches m2 2.046 2.046 2.046 2.046 2.502 2.502 3.128 3.128 3.128 Rows/Fin Series #/FPF 2 or 3 / 192 2 or 3 / 192 3 / 192 3 / 192 3 / 192 3 / 192 3 / 192 3 / 192 3 / 192 48.0 48.0 48.0 48.0 48.0 48.0 60.0 60.0 60.0 Tube Size Number of Tubes in the height Indoor Coil Type Fins & Tubes Fins & Tubes Fins & Tubes Fins & Tubes Fins & Tubes Fins & Tubes Fins & Tubes Fins & Tubes Fins & Tubes 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" Face Area Inches m2 1.8 1.8 1.8 1.8 2.4 2.4 3.0 3.0 3.0 Rows/Fin Series #/FPF 3 / 168 3 / 168 3 / 168 4 / 168 4 / 168 4 / 168 4 / 168 4 / 168 4 / 168 48.0 48.0 48.0 48.0 48.0 48.0 60.0 60.0 60.0 mm 35.0 35.0 35.0 35.0 35.0 35.0 35.0 35.0 35.0 Fins&TubesHWC01 Fins&TubesHWC01 Fins&TubesHWC01 Fins&TubesHWC01 Fins&TubesHWC02 Fins&TubesHWC02 Fins&TubesHWC02 Fins&TubesHWC02 Fins&TubesHWC02 Tube Size Number of Tubes in the height Drain Connection No./Size Hot Water Coil Type Inches m2 3/8'' 3/8'' 3/8'' 3/8'' 3/8'' 3/8'' 3/8'' 3/8'' 3/8'' Face Area Tube Size 0.769 0.769 0.769 0.769 1.087 1.087 1.087 1.087 1.087 Rows/Fin Series #/FPF 2 / 144 2 / 144 2 / 144 2 / 144 2/144 2/144 2/144 2/144 2/144 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 Number of Tubes in the height RT-SVX056D-GB 11 IC - IH General Data Table 2 – Dual compressor circuit (continued) IC - IH 040 IC - IH 050 IC - IH 060 IC - IH 065 IC - IH 075 IC - IH 085 IC - IH 100 IC - IH 110 IC - IH 130 Plug Fans Plug Fans Plug Fans Plug Fans Plug Fans Plug Fans Plug Fans Plug Fans Plug Fans Indoor Fan Standard Type Model Minimum Airflow Nominal Airflow Maximal Airflow Number Diameter m3/h m3/h 6960.0 8480.0 9680.0 10960.0 12560.0 13360.0 15840.0 17280.0 20400.0 8700.0 10600.0 12100.0 13700.0 15700.0 16700.0 19800.0 21600.0 25500.0 11310.0 13780.0 15730.0 17810.0 20410.0 21710.0 25740.0 28080.0 33150.0 # 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 mm 450.0 450.0 450.0 450.0 500.0 500.0 500.0 500.0 500.0 EC Motors m3/h Drive Type Motor Power (Eurovent condition) Motor Max Amps per fan Motor RPM at nominal flow rate (Eurovent condition) Available Static Pressure at nominal flow rate K3G450PA2371 K3G450PA2371 K3G450PA2371 K3G450PA2371 K3G500PA2371 K3G500PA2371 K3G500PB3301 K3G500PB3301 K3G500PB3301 EC Motors EC Motors EC Motors EC Motors EC Motors EC Motors EC Motors EC Motors kW 1.1 1.2 1.4 2.2 2.3 2.6 3.3 3.9 5.7 A 4.7 4.7 4.7 4.7 5.3 5.3 9.0 9.0 9.0 RPM 1091.8 1242.4 1332.2 1573.4 1357.9 1425.8 1586.7 1681.8 1941.5 Pa 250.0 250.0 250.0 250.0 250.0 250.0 250.0 250.0 250.0 Plug Fans Plug Fans Plug Fans Plug Fans Plug Fans Plug Fans Plug Fans Plug Fans Plug Fans Oversized Type Model Minimum Airflow Nominal Airflow Maximal Airflow Number Diameter m3/h m3/h 6960 8480 9680 10960 12560 13360 15840 17280 20400 m3/h 8700 10600 12100 13700 15700 16700 19800 21600 25500 11310 13780 15730 17810 20410 21710 25740 28080 33150 # 2 2 2 2 2 2 2 3 3 mm 450 450 450 500 500 500 500 500 500 EC Motors Drive Type Motor Power (Eurovent condition) Motor Max Amps per fan Motor RPM at nominal flow rate (Eurovent condition) Available Static Pressure at nominal flow rate K3G450PA2371 K3G450PA2371 K3G450PA2371 K3G500PA2371 K3G500PA2371 K3G500PB3301 K3G500PB3301 K3G500PB3301 K3G500PB3301 EC Motors EC Motors EC Motors EC Motors EC Motors EC Motors EC Motors EC Motors kW 1.1 1.2 1.4 2.1 2.3 2.7 3.3 3.2 4.5 A 4.7 4.7 4.7 5.3 5.3 9.0 9.0 9.0 9.0 RPM 1091.8 1242.4 1332.2 1281.1 1357.9 1422.8 1586.7 1294.9 1470.6 Pa 500 500 500 500 500 500 500 500 500 Axial / Below / AC Axial / Below / AC Axial / Below / AC Axial / Below / AC Axial / Below / AC Axial / Below / AC Axial / Below / AC Axial / Below / AC Axial / Below / AC Outdoor Fan Standard Ambient Type Model Nominal Airflow m3/h A8D800A10105 A8D800A10105 A8D800A10105 A8D800A10105 A8D800A10105 A8D800A10105 A8D800A10105 A8D800A10105 A6D800AH0101 13694.0 13687.1 13681.4 13674.7 14321.0 14317.8 14865.3 14859.9 # 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 Diameter mm 800.0 800.0 800.0 800.0 800.0 800.0 800.0 800.0 800.0 Motor Power per fan kW 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 1.44 A 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.9 rpm 686.0 686.0 686.0 686.0 686.0 686.0 686.0 686.0 900.0 Axial / Below / EC Axial / Below / EC Axial / Below / EC Axial / Below / EC Axial / Below / EC Axial / Below / EC Axial / Below / EC Axial / Below / EC Axial / Below / EC Number of fan / ckt Motor Max Amps per fan Motor RPM 19628.3 Low Ambient Type Model Nominal Airflow m3/h A3G800AS3905 A3G800AS3905 A3G800AS3905 A3G800AS3905 A3G800AS3905 A3G800AS3905 A3G800AS3905 A3G800AS3905 A3G800AS3905 13694.0 13687.1 13681.4 13674.7 14321.0 14317.8 14865.3 14859.9 # 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 Diameter mm 690.0 690.0 690.0 690.0 690.0 690.0 690.0 690.0 930.0 Motor Power per fan kW 1.95 1.95 1.95 1.95 1.95 1.95 1.95 1.95 1.95 A 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 rpm 686.0 686.0 686.0 686.0 686.0 686.0 686.0 686.0 900.0 Number Motor Max Amps per fan Motor RPM 19628.3 Physical Data for Standard Unit (4) Length mm 3010 3010 3010 3010 3890 3890 3890 3890 3890 Width mm 2250 2250 2250 2250 2250 2250 2250 2250 2250 Height mm 1565 1565 1565 1565 1585 1585 1890 1890 1890 IC Operating Weight (Downflow Without Auxiliary Heat) kg 1050 1062 1092 1129 1311 1317 1533 1537 1537 IC Shipping Weight (Downflow Without Auxiliary Heat) kg 1106 1118 1148 1185 1371 1377 1593 1597 1597 IH Operating Weight (Downflow Without Auxiliary Heat) kg 1100 1112 1116 1153 1342 1348 1566 1570 1570 IH Shipping Weight (Downflow Without Auxiliary Heat) kg 1156 1168 1172 1209 1402 1408 1626 1630 1630 Options Extra Weight (4) 12 Hot Water Coil kg 48 48 48 48 59 59 65 65 65 Electric Heater kg 22 22 22 22 26 26 29 29 29 Gas Burner: staged kg 76 76 90 90 118 118 118 118 118 Gas Burner: modulating condensing kg 76 76 90 90 118 118 138 138 138 535 Energy Recovery Module kg 375 375 375 375 455 455 535 535 Exhaust Fan kg 24 24 24 24 39 39 43 43 43 Return Roofcurb Down kg 380 380 380 390 470 470 470 470 490 Return Roofcurb Horizontal kg 280 280 280 290 350 350 350 350 370 Downflow Adjustable Roofcurb kg 150 150 150 150 170 170 170 170 170 Multidirectional Roofcurb kg 190 190 190 190 220 220 220 220 220 RT-SVX056D-GB IC - IH General Data Table 2 – Dual compressor circuit (continued) IC - IH 040 Energy Recovery Module (ERM) IC - IH 050 IC - IH 060 IC - IH 065 IC - IH 075 IC - IH 085 IC - IH 100 IC - IH 110 IC - IH 130 m3/h m3/h m3/h 9500 9500 9500 9500 9500 9500 10000 10000 10000 18000 18000 18000 18000 18000 18000 28000 28000 28000 2500 2500 2500 2500 2500 2500 3900 3900 3900 Exchanger Wheel Diameter mm 1200.0 1200.0 1200.0 1200.0 1200.0 1200.0 1500.0 1500.0 1500.0 Max Exhaust Air @ ESP=400Pa Max Fresh Air @ Wheel PD=300Pa Min Wheel Airflow Exhaust Air Fan Diameter mm 400.0 400.0 400.0 400.0 400.0 400.0 400.0 400.0 400.0 Exhaust Air Fan Motor Power kW 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 Length x Width x Height mm Weight kg 1750x1180x1510 1750x1180x1510 1750x1180x1510 1750x1180x1510 2250x1180x1530 2250x1180x1530 2250x1180x1835 2250x1180x1835 2250x1180x1835 375.0 375.0 375.0 375.0 455.0 455.0 535.0 535.0 535.0 Gas Burner Gas burner type - Premium modulating Thermal output (Hi) [Min-Max] Useful heat output [Min-Max] Gas Flow [Min-Max] (5) PCH045 PCH045 PCH065 PCH065 PCH080 PCH080 PCH105 PCH105 PCH105 kW 8,50 - 42,0 8,50 - 42,0 12,40 - 65,0 12,40 - 65,0 16,40 - 82 16,40 - 82 21,0 - 100,0 21,0 - 100,0 21,0 - 100,0 kW m3/h 8,97 - 40,45 8,97 - 40,45 13,40 - 62,93 13,40 - 62,93 17,77 - 80,03 17,77 - 80,03 22,77 - 97,15 22,77 - 97,15 22,77 - 97,15 0,90 - 4,45 0,90 - 4,45 1,31 - 6,88 1,31 - 6,88 1,74 - 8,68 1,74 - 8,68 2,22 - 10,58 2,22 - 10,58 2,22 - 10,58 Flue gas emission Carbon monoxide - CO - (0% of O2) (5) Nitrogen oxides - NOx (0% of O2) (5) CO2 max (5) ppm <5 <5 <5 <5 <5 <5 <5 <5 <5 mg/KWh -ppm 19 - 33 19 - 33 22 - 39 22 - 39 18 - 32 18 - 32 23 - 41 23 - 41 23 - 41 % 9.1 9.1 9.1 9.1 9.1 9.1 9.1 9.1 9.1 UNI/ISO 228/1-G 3/4" UNI/ISO 228/1-G 3/4" UNI/ISO 228/1-G 3/4" UNI/ISO 228/1-G 3/4" UNI/ISO 228/1-G 3/4" UNI/ISO 228/1-G 3/4" UNI/ISO 228/1-G 3/4" UNI/ISO 228/1-G 3/4" UNI/ISO 228/1-G 3/4" Gas Connection Pipe Diameter Energy Recovery Circuit (ERC) Cooling Mode Net Cooling Capacity (ERC only) kW 15.5 15.7 15.8 16 21.3 21.4 26.5 26.7 27 ERC Compressor Power Input kW 3.7 3.7 3.7 3.7 4.1 4.1 5.9 5.9 5.9 ERC Exhaust Fans Power Input kW 0.5 0.5 0.5 0.5 0.9 0.9 0.9 0.9 0.9 Total ERC Power Input kW 4.2 4.2 4.2 4.2 5 5 6.8 6.8 6.8 Net Cooling Capacity (ERC + IH standard) kW 64.6 76.1 84.5 93 111.3 115.5 137.5 147.7 170 Total Power Input (ERC + IH standard) kW 17.7 21.3 23.9 28.9 33.4 36.4 42.4 48.4 59.1 Heating Mode Net Heating Capacity (ERC only) kW 15 15 14.9 15 21.1 21.1 27 27 27 ERC Compressor Power Input kW 2.4 2.3 2.3 2.3 2.7 2.7 3.9 3.9 3.8 ERC Exhaust Fans Power Input kW 0.5 0.5 0.5 0.5 0.9 0.9 0.9 0.9 0.9 Total ERC Power Input kW 2.9 2.8 2.8 2.8 3.6 3.6 4.8 4.8 4.7 Net Heating Capacity (ERC + IH standard) kW 54.2 64.7 70.9 80.3 94.7 100 120.8 132.9 154.8 Total Power Input (ERC + IH standard) kW 14.3 17.3 19.9 21.9 24.7 26.4 31.6 35.4 42.8 Exhaust Fans & air management (7) Number of Exhaust Fans Exhaust Air Fans Type Exhaust Air Fans Model Exhaust Air Fans Diameter 1 1 1 1 2 2 2 2 2 Axial / AC Axial / AC Axial / AC Axial / AC Axial / AC Axial / AC Axial / AC Axial / AC Axial / AC W4D450CO1401 W4D450CO1401 W4D450CO1401 W4D450CO1401 W4D450CO1401 W4D450CO1401 W4D450CO1401 W4D450CO1401 W4D450CO1401 mm 450 450 450 450 450 450 450 450 Minimum Fresh Air % 20 20 20 20 20 20 20 20 450 20 Maximum Recommended Fresh Air (compared to max airflow) % 47 39 34 30 50 47 41 38 32 Maximum Fresh Air (building pressurisation issues to be considered) % 100 100 100 100 100 100 100 100 100 Maximum Return Air Pressure Drop (without Return Roofcurb) Pa 100 100 100 100 100 100 100 100 100 Maximum Additional Air Pressure Drop (indoor coil) Pa 10 15 25 25 20 20 20 25 25 Oil & Refrigerant (7)(6) ERC Circuit Refrigerant Charge ERC Circuit Oil Quantity kg 2.3 2.3 2.3 2.3 2.7 2.7 3.4 3.4 3.4 l 1.24 1.24 1.24 1.24 1.24 1.24 1.24 1.24 1.24 Dimensions and weights (7)(6) Length x Width x Height (ERC + IH standard) Weight (ERC + IH standard) mm kg 3010x2250x1565 3010x2250x1565 3010x2250x1565 3010x2250x1565 3890x2250x1585 3890x2250x1585 3890x2250x1585 3890x2250x1585 3890x2250x1585 1229 1241 1245 1282 1516 1522 1751 1755 1755 (1) (2) (3) (4) (5) (6) Indicative performances. For detailled performances, consult order write up (OWU). Under 400V/50Hz/3Ph. Electrical & system data are indicative and subject to change without notice. Please refer to unit nameplate data. Indicative data. For details consult lifting and handling instructions in document package shipped with the unit. Value referenced to Gas G20 - for other refer to burner IOM manual. OIL058E or OIL057E are European reference for POE oil and can be mixed in any proportion with OIL00078 or OIL00080 (same oil with US reference on compressor nameplate). (7) IH unit only. (8) The ERM data is only for Digit -18 R. RT-SVX056D-GB 13 IC - IH General Data Table 3 – Single circuit IC 038 IH 038 IC 048 IH 048 IC 058 IC 063 Cooling Mode Net Cooling Capacity (1) kW 41 40 50 50 61 69 Total Power Input (1) kW 14.0 13.41 16.6 17.6 20.7 25.1 Electric Heater Number of capacity step Nb 2 2 2 2 2 2 Capacity Steps (1) kW 12,5 / 12,5 12,5 / 12,5 12,5 / 12,5 12,5 / 12,5 12,5 / 25 12,5 / 25 400 / 3 /50 Electrical Data (2) (3) Main Power Supply V/Ph/Hz 400 / 3 /50 400 / 3 /50 400 / 3 /50 400 / 3 /50 400 / 3 /50 Unit Max Amps A 37 37 45 45 54 63 Unit Start Up Amps (without soft starter) A 124 124 156 156 173 185 Unit Start Up Amps (with soft starter) A 88 88 111 111 125 134 Maximum Short Circuit rating for 0.3 sec kA 15 15 15 15 15 15 Disconnect switch std unit Max power cable cross section (Standard unit) Sirco 125A mm2 50 Disconnect switch unit with option (heat recovery, Exhaust fan, Return Fan, Auxiliary heat) Max power cable cross section (unit with option-Heat recovery, Exhaust fan, Return fan, Auxiliary heat) Sirco 250A mm2 150 Electric Heater A 36.1 36.1 36.1 36.1 36.1 36.1 Outdoor fan: Low Ambient A 0.8 0.8 1.6 0.8 1.6 1.6 Indoor fan: Oversized A 0.0 0.0 0.0 0.0 0.0 0.0 Exhaust Fan (AC) A 0.6 0.6 0.6 0.6 0.6 0.6 Exhaust Fan (EC) A 5 5 5 5 5 5 Return Roofcurb A 5.3 5.3 5.3 5.3 5.3 5.3 Heat Recovery (not included current for oversized fan) A 7.5 7.5 7.5 7.5 7.5 7.5 Gas burner (staged) A 0.4 0.4 0.4 0.4 0.4 0.4 Gas burner (modulating) A 0.3 0.3 0.3 0.3 0.3 0.3 Frame 1 Frame 1 1 Frame Frame Frame 1 Frame 1 Compressor Number of Circuits # 1 1 1 1 1 Number of Compressor per Circuits # 2 2 2 2 2 2 Scroll Scroll Scroll Scroll Scroll Scroll Type Model ZP83KCE TFD 422 ZP83KCE TFD 422 ZP104KCE TFD455 ZP83KCE TFD 422 ZP122KCE TFD 455 ZP143KCE TFD 455 Max Amps per Compressor A 14.3 14.3 17.1 17.1 20.1 24.5 Locked Rotor Amps per Compressor A 101 101 128 128 139 146 Oil & Refrigerant Oil quantity per compressors OIL58E/OIL57E (6) l 1.8 1.8 2.5 2.5 2.5 2.5 Oil quantity OIL58E/OIL57E (6) l 3.5/3.5 3.6 5.0/5.0 5.0 5.0/5.0 5.0/5.0 kg 4.33 4.33 7.44 7.44 7.20 7.70 MCHE Fins & Tubes MCHE Fins & Tubes MCHE MCHE 2.92 2.92 Refrigerant charge per circuit Outdoor Coil Type Tube Size Face Area Inches m2 Rows/Fin Series #/FPF Number of Tubes in the height 5/16” 2.92 2.05 5/16” 2.92 3 / 192 2.92 3 / 192 128 (96-32) 48 128 (96-32) 48 128 (96-32) 128 (96-32) Fins & Tubes Fins & Tubes Indoor Coil Type Fins & Tubes Fins & Tubes Fins & Tubes Fins & Tubes 3/8" 3/8” 3/8" 3/8” 3/8" 3/8" Face Area Inches m2 1.812 1.812 1.812 1.812 1.812 1.812 Rows/Fin Series #/FPF 3 / 168 3 / 168 3 / 168 3 / 168 3 / 168 3 / 168 48 48 48 48 48 48 35 35 35 35 35 35 Fins & Tubes Fins & Tubes Tube Size Number of Tubes in the height Drain Connection No./Size mm Hot Water Coil Type Fins & Tubes Fins & Tubes Fins & Tubes Fins & Tubes 3/8" 3/8” 3/8" 3/8” 3/8" 3/8" Face Area Inches m2 0.769 0.769 0.769 0.769 0.769 0.769 Rows/Fin Series #/FPF 2 / 144 2 / 144 2 / 144 2 / 144 2 / 144 2 / 144 25 25 25 25 25 25 Tube Size Number of Tubes in the height Indoor Fan Standard Type Model Plug Fans Plug Fans Plug Fans Plug Fans Plug Fans K3G500PA2371 K3G500PA2371 K3G500PA2371 K3G500PB3301 K3G500PB3301 6240 6240 7200 7200 8880 10300 7800 7800 9000 9000 11100 12400 16120 Nominal Airflow m3/h m3/h Maximal Airflow m3/h 10140 10140 11700 11700 14430 # 1 1 1 1 1 1 mm 500 500 500 500 500 500 Minimum Airflow Number Diameter Drive Type Motor Power (Eurovent condition) Motor Max Amps per fan 14 Plug Fans K3G500PA2371 EC Motors EC Motors EC Motors EC Motors EC Motors EC Motors kW 0.93 0.93 1.15 1.15 1.91 2.59 A 5.3 5.3 5.3 5.3 9 9 RT-SVX056D-GB IC - IH General Data Table 3 – Single circuit (continued) Motor RPM at nominal flow rate (Eurovent condition) Available Static Pressure at nominal flow rate IC 038 IH 038 IC 048 IH 048 RPM 1221 1176 1362 1385 Pa 250 250 250 250 IC 058 IC 063 250 250 Oversized Type Model Minimum Airflow Nominal Airflow Maximal Airflow Number Diameter Plug Fans Plug Fans Plug Fans Plug Fans Plug Fans Plug Fans K3G500PA2371 K3G500PA2371 K3G500PA2371 K3G500PA2371 K3G500PB3301 K3G500PB3301 6560 6240 8000 7200 8880 10300 m3/h 8200 7800 10000 9000 11100 12400 10660 10140 13000 11700 14430 16120 # 1 1 1 1 1 1 mm 500 500 500 500 500 500 m3/h m3/h Drive Type Motor Power (Eurovent condition) Motor Max Amps per fan Motor RPM at nominal flow rate (Eurovent condition) Available Static Pressure at nominal flow rate EC Motors EC Motors EC Motors EC Motors EC Motors EC Motors kW 0.929 0.929 1.15 1.15 1.91 2.59 A 5.3 5.3 5.3 5.3 9 9 RPM 1221 1176 1362 1385 1632 1829 Pa 500 500 500 500 500 500 Outdoor Fan Standard Ambient Type Axial / Below / AC Axial / Below / AC Axial / Below / AC Axial / Below / AC A8D800A10105 A8D800A10105 A8D800A10105 A8D800A10105 A8D800A10105 A8D800A10105 14543 14543 12078.5 12078.5 12078.5 12078.5 # 1 1 2 2 2 2 Diameter mm 800 800 800 800 800 800 Motor Power per fan kW 0.89 0.89 0.89 0.89 0.89 0.89 A 2.22 2.22 2.22 2.22 2.22 2.22 rpm 686 686 686 686 686 686 Model Nominal Airflow / ckt Number of fan / ckt Motor Max Amps per fan Motor RPM Axial / Below / AC Axial / Below / AC m3/h Low Ambient Type Axial / Below / EC Axial / Below / EC Axial / Below / EC Axial / Below / EC A3G800AS3905 A3G800AS3905 A3G800AS3905 A3G800AS3905 A3G800AS3905 A3G800AS3905 7433 7433 12078 12078 12078 120278 # 1 1 2 2 2 2 Diameter mm 800 800 800 800 800 800 Motor Power per fan kW 1.95 1.95 1.95 1.95 1.95 1.95 A 3 3 3 3 3 3 rpm 686 686 686 686 686 686 Length mm 2830 2830 2830 2830 2830 2830 Width mm 2250 2250 2250 2250 2250 2250 Height mm 1565 1565 1565 1565 1565 1565 IC Operating Weight (Downflow Without Auxiliary Heat) kg 864 949 924 1033 935 935 IC Shipping Weight (Downflow Without Auxiliary Heat) kg 920 1005 980 1089 991 991 Hot Water Coil kg 48 48 48 48 48 48 Electric Heater kg 22 22 22 22 22 22 Gas Burner: modulating condensing kg 76 76 76 76 90 90 Energy Recovery Module kg 375 375 375 375 375 375 Exhaust Fan kg 24 24 24 24 24 24 Return Roofcurb Down kg 380 380 380 380 380 390 Return Roofcurb Horizontal kg 280 280 280 280 280 290 Downflow Adjustable Roofcurb kg 150 150 150 150 150 150 Multidirectional Roofcurb kg 190 190 190 190 190 190 m3/h m3/h 9500 9500 9500 9500 9500 9500 18000 18000 18000 18000 18000 18000 2500 2500 2500 2500 2500 2500 1200 1200 1200 1200 1200 1200 Model Nominal Airflow Number Motor Max Amps per fan Motor RPM Axial / Below / EC Axial / Below / EC m3/h Physical Data for Standard Unit Options Extra Weight (4) Energy Recovery Module (ERM) Max Exhaust Air @ ESP=400Pa Max Fresh Air @ Wheel PD=300Pa Min Wheel Airflow m3/h Exchanger Wheel Diameter mm Exhaust Air Fan Diameter mm 400 400 400 400 400 400 Exhaust Air Fan Motor Power kW 3.35 3.35 3.35 3.35 3.35 3.35 Length x Width x Height mm 1750x1180x1510 1750x1180x1510 1750x1180x1510 1750x1180x1510 1750x1180x1510 1750x1180x1510 kg 375 375 375 375 375 375 PCH065 PCH065 kW 8,50 - 42,0 8,50 - 42,0 8,50 - 42,0 8,50 - 42,0 12,40 - 65,0 12,40 - 65,0 kW 8,97 - 40,45 8,97 - 40,45 8,97 - 40,45 8,97 - 40,45 13,40 - 62,93 13,40 - 62,93 1,31 - 6,88 1,31 - 6,88 Weight Gas Burner Gas burner type - Premium modulating Thermal output (Hi) [Min-Max] Useful heat output [Min-Max] Gas Flow [Min-Max] (5) PCH045 m3/h 0,90 - 4,45 PCH045 0,90 - 4,45 Flue gas emission Carbon monoxide - CO - (0% of O2) (5) Nitrogen oxides - NOx - (0% of O2) (6) CO2 max (5) Gas Connection Pipe Diameter ppm <5 <5 <5 <5 mg/KWh -ppm 19 - 33 19 - 33 22 - 39 22 - 39 % 9.1 9.1 9.1 9.1 UNI/ISO 228/1-G 3/4” UNI/ISO 228/1-G 3/4” UNI/ISO 228/1-G 3/4" UNI/ISO 228/1-G 3/4" (1) (2) (3) (4) (5) (6) Indicative performances. For detailled performances, consult order write up (OWU). Under 400V/50Hz/3Ph. Electrical & system data are indicative and subject to change without notice. Please refer to unit nameplate data. Indicative data. For details consult lifting and handling instructions in document package shipped with the unit. Value referenced to Gas G20 - for other refer to burner IOM manual. OIL058E or OIL057E are European reference for POE oil and can be mixed in any proportion with OIL00078 or OIL00080 (same oil with US reference on compressor nameplate). (7) The ERM data is only for Digit -18 R. RT-SVX056D-GB 15 IH General Data Table 4 – AFD IH 021 IH 031 IH 041 IH 051 IH 061 IH 071 Cooling Mode Net Cooling Capacity (1) kW 20 30 40 50 60 64 Total Power Input (1) kW 4.6 8.0 10.6 14.7 20.1 22.9 Heating Mode Net Heating Capacity (1) kW 20 30 40 50 59 59 Power Input (1) kW 5.3 7.9 11.4 14.6 18.2 18.2 Electric Heater Number of capacity step Nb 2 2 2 2 2 2 Capacity Steps (1) kW 12.5 / 12.5 12.5 / 12.5 12.5 / 12.5 12.5 / 12.5 12.5 / 25 12.5 / 25 Electrical Data (2) (3) Main Power Supply V/Ph/Hz 400 / 3 /50 400 / 3 /50 400 / 3 /50 400 / 3 /50 400 / 3 /50 400 / 3 /50 Unit Max Amps A 35 35 46 46 50 50 Unit Start Up Amps (= Unit Max Amps - only 1 compressor with VFD) A 35 35 46 46 50 50 Maximum Short Circuit rating for 0,3 sec kA 15 15 15 15 15 15 Max power cable cross section (Standard unit) mm2 50 50 50 50 50 50 Max power cable cross section (unit with option-Heat recovery, Exhaust fan, Return fan, Auxiliary heat) mm2 150 150 150 150 150 150 Disconnect switch std unit Sirco 125A Sirco 125A Sirco 125A Sirco 125A Sirco 125A Sirco 125A Disconnect switch unit with option (heat recovery, Exhaust fan, Return Fan,Auxiliary heat) Sirco 250A Sirco 250A Sirco 250A Sirco 250A Sirco 250A Sirco 250A Electrical data of options (2) (3) Electric Heater A 36.1 36.1 36.1 36.1 54.1 54.1 Outdoor fan: Low Ambient A 0.8 0.8 1.6 1.6 1.6 1.6 Indoor fan: Oversized A 0.6 0.6 4.3 4.3 0.0 0.0 Exhaust Fan (AC fan) 0.6 0.6 0.6 0.6 0.6 0.6 Exhaust Fan (EC fan) A A 5.2 5.2 5.2 5.2 5.2 5.2 Return Roofcurb A 5.3 5.3 5.3 5.3 5.3 5.3 Heat Recovery (not included current for oversized fan) A 7.5 7.5 7.5 7.5 7.5 7.5 Gas burner (modulating) A 0.3 0.3 0.3 0.3 0.3 0.3 # Frame S1 Frame S1 Frame S1 Frame S1 Frame S1 Frame S1 Number of Circuits # 1 1 1 1 1 1 Number of Compressor per Circuits # 1 1 1 1 1 1 Scroll Scroll Scroll Scroll Scroll Scroll Scroll Model (drive/compressor) # CDS803/VZH088 CDS803/VZH088 CDS803/VZH117 CDS803/VZH117 CDS803/VZH117 CDS803/VZH117 Crank Case Heater W 84 84 84 84 84 84 Electrical data of options (2) (3) A # # # # # # Locked Rotor Amps per Compressor A # # # # # # Oil quantity per compressors OIL58E/OIL57E (6) l 3.8 3.8 4.1 4.1 4.1 4.1 Oil quantity OIL58E/OIL57E (6) l 3.8 3.8 4.1 4.1 4.1 4.1 kg 12 12 14 14 14 14 Fins & Tubes Frame Frame Compressor + Drive Type Oil & Refrigerant Refrigerant charge per circuit Outdoor Coil Type # Fins & Tubes Fins & Tubes Fins & Tubes Fins & Tubes Fins & Tubes Tube Size Inches 5/16" 5/16" 5/16" 5/16" 5/16" 5/16" Face Area m2 2.502 2.502 2.952 2.952 2.952 2.952 #/FPF 3 / 192 3 / 192 3 / 192 3 / 192 3 / 192 3 / 192 # 48 48 48 48 48 48 Fins & Tubes Rows/Fin Series Number of Tubes in the height Indoor coil # Fins & Tubes Fins & Tubes Fins & Tubes Fins & Tubes Fins & Tubes 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" Face Area Inches m2 1.841 1.841 1.841 1.841 1.841 1.841 Rows/Fin Series #/FPF 3 / 168 3 / 168 4 / 168 4 / 168 4 / 168 4 / 168 # 48 48 48 48 48 48 mm 35 35 35 35 35 35 Fins & Tubes Type Tube Size Number of Tubes in the height Drain Connection No./Size Hot Water Coil Type # Fins & Tubes Fins & Tubes Fins & Tubes Fins & Tubes Fins & Tubes Tube Size Inches 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" Face Area m2 0.769 0.769 0.769 0.769 0.769 0.769 #/FPF 2 / 144 2 / 144 2 / 144 2 / 144 2 / 144 2 / 144 # 25 25 25 25 25 25 Rows/Fin Series Number of Tubes in the height Indoor Fan Standard Type # Plug Fans Plug Fans Plug Fans Plug Fans Plug Fans Plug Fans Model # K3G450PA2371 K3G450PA2371 K3G450PA2371 K3G500PA2371 K3G500PB3301 K3G500PB3301 Minimum Airflow m3/h 3088 4632 6176 7720 9264 9573 Nominal Airflow m3/h 3860 5790 7720 9650 11580 11966 Maximal Airflow m3/h 5018 7527 10036 12545 15054 15556 # 1 1 1 1 1 1 mm 450 450 450 500 500 500 Number Diameter Drive Type Motor Power (Eurovent condition) Motor Max Amps per fan Motor RPM at nominal flow rate Available Static Pressure at nominal flow rate 16 # EC Motors EC Motors EC Motors EC Motors EC Motors EC Motors kW 0.220 0.452 0.822 1.200 1.848 1.998 A 4.7 4.7 4.7 5.3 9 9 RPM 831 1145 1465 1411 1650 1699 Pa 250 250 250 250 250 250 RT-SVX056D-GB IH General Data Table 4 – AFD (continued) IH 021 IH 031 IH 041 IH 051 IH 061 IH 071 Oversized Type Plug Fans Plug Fans Plug Fans Plug Fans Plug Fans Plug Fans # K3G450PA2371 K3G450PA2371 K3G500PA2371 K3G500PB3301 K3G500PB3301 K3G500PB3301 Minimum Airflow m3/h 3088 4632 6176 7720 9264 9573 Nominal Airflow m3/h 3860 5790 7720 9650 11580 11966 Maximal Airflow m3/h 5018 7527 10036 12545 15054 15556 # 1 1 1 1 1 1 mm 450 450 500 500 500 500 Model Number Diameter Drive Type Motor Power (Eurovent condition) Motor Max Amps per fan Motor RPM at nominal flow rate Available Static Pressure at nominal flow rate # EC Motors EC Motors EC Motors EC Motors EC Motors EC Motors kW 0.220 0.452 0.691 1.226 1.848 1.998 A 4.7 4.7 5.3 9 9 9 RPM 831 1145 1148 1408 1650 1699 Pa 500 500 500 500 500 500 Outdoor Fan Standard Ambient Type Axial / Below / AC Axial / Below / AC Axial / Below / AC Axial / Below / AC # A8D800A10105 A8D800A10105 A8D800A10105 A8D800A10105 A8D800A10105 A8D800A10105 m3/h 14566 14560 24910 24897 24884 24879 # 1 1 2 2 2 2 Diameter mm 800 800 800 800 800 800 Motor Power per fan kW 0.89 0.89 0.89 0.89 0.89 0.89 A 2.22 2.22 2.22 2.22 2.22 2.22 rpm 686 686 686 686 686 686 Model Nominal Airflow / ckt Number of fan / ckt Motor Max Amps per fan Motor RPM Axial / Below / AC Axial / Below / AC Low Ambient Type Axial / Below / EC Axial / Below / EC Axial / Below / EC Axial / Below / EC # A3G800AS3905 A3G800AS3905 A3G800AS3905 A3G800AS3905 A3G800AS3905 A3G800AS3905 m3/h 14566 14560 24910 24897 24884 24879 # 1 1 2 2 2 2 Diameter mm 800 800 800 800 800 800 Motor Power per fan kW 1.95 1.95 1.95 1.95 1.95 1.95 A 3 3 3 3 3 3 rpm 686 686 686 686 686 686 Length mm 2830 2830 2830 2830 2830 2830 Width mm mm 2250 2250 2250 2250 2250 2250 1565 1565 1565 1565 1565 1565 Operating Weight (Without Auxiliary Heat) kg 884 884 966 966 966 966 Shipping Weight (Without Auxiliary Heat) kg 940 940 1022 1022 1022 1022 Hot Water Coil kg 48 48 48 48 48 48 Electric Heater kg 22 22 22 22 26 26 Gas Burner: modulating condensing kg 76 76 76 76 90 90 Energy Recovery Module kg 375 375 375 375 375 375 Exhaust Fan (EC) kg 24 24 24 24 24 24 Exhaust Fan (AC) kg 81 81 81 81 81 81 Return Roofcurb Down kg 380 380 380 380 390 390 Return Roofcurb Horizontal kg 280 280 280 280 290 290 Downflow Adjustable Roofcurb kg 150 150 150 150 150 150 Multidirectional Roofcurb kg 190 190 190 190 190 190 Model Nominal Airflow Number Motor Max Amps per fan Motor RPM Axial / Below / EC Axial / Below / EC Physical Data for Standard Unit (4) Height Options Extra Weight (4) Energy Recovery Module (ERM) Max Exhaust Air @ ESP=400Pa m3/h 9500 9500 9500 9500 9500 9500 Max Fresh Air @ Wheel PD=300Pa m3/h 18000 18000 18000 18000 18000 18000 Min Wheel Airflow m3/h 2500 2500 2500 2500 2500 2500 Exchanger Wheel Diameter mm 1200 1200 1200 1200 1200 1200 Exhaust Air Fan Diameter mm 400 400 400 400 400 400 Exhaust Air Fan Motor Power kW 3.4 3.4 3.4 3.4 3.4 3.4 Length x Width x Height mm 1750x1175x1575 1750x1175x1575 1750x1175x1575 1750x1175x1575 1750x1175x1575 1750x1175x1575 kg 396 396 396 396 396 396 Weight Gas Burner Gas burner type - modulating condensing Thermal output (Hi) [Min-Max] Useful heat output [Min-Max] # PCH045 PCH045 PCH045 PCH045 PCH065 PCH065 kW 8,50 - 42,0 8,50 - 42,0 8,50 - 42,0 8,50 - 42,0 12,40 - 65,0 12,40 - 65,0 kW 8,97 - 40,45 8,97 - 40,45 8,97 - 40,45 8,97 - 40,45 13,40 - 62,93 13,40 - 62,93 m3/h 0,90 - 4,44 0,90 - 4,44 0,90 - 4,44 0,90 - 4,44 1,31 - 6,88 1,31 - 6,88 Carbon monoxide - CO - (0% of O2) (5) ppm <5 <5 <5 <5 <5 <5 Nitrogen oxides - NOx - (0% of O2) (5) mg/KWh 33 33 33 33 39 39 CO2 max (5) % 9.1 9.1 9.1 9.1 9.1 9.1 Gas Connection Pipe Diameter # UNI/ISO 228/1 G3/4" UNI/ISO 228/1 G3/4" UNI/ISO 228/1 G3/4" UNI/ISO 228/1 G3/4" "UNI/ISO 228/1 G3/4""" "UNI/ISO 228/1 G3/4""" Gas Flow [Min-Max] (5) Flue gas emission (1) (2) (3) (4) (5) (6) Indicative performances. For detailled performances, consult order write up (OWU). Under 400V/50Hz/3Ph. Electrical & system data are indicative and subject to change without notice. Please refer to unit nameplate data. Indicative data. For details consult lifting and handling instructions in document package shipped with the unit. Value referenced to Gas G20 - for other refer to burner IOM manual. OIL058E or OIL057E are European reference for POE oil and can be mixed in any proportion with OIL00078 or OIL00080 (same oil with US reference on compressor nameplate). (7) The ERM data is only for Digit -18 R. RT-SVX056D-GB 17 Unit Operating Principle This section describes the overall flow chart principle for Airfinity. Detailed information for a given order is supplied with order package documentation. Figure 1 – Example of Typical Refrigerant System Schematic & Oil Lube Circuit Schematic 18 RT-SVX056D-GB Installation General information: The installation must conform to all local standards and regulations. Reception of Units Unit Handling The unit is supplied on wooden blocks. It is recommended to check the machine’s condition upon reception. There are two ways to handle the unit: 1. Handle the machine using a forklift, in accordance with applicable safety regulations. Handling of the unit is prohibited unless forks are longer than the length of the unit (not recommended as there is a risk of damage if not done carefully). 2. Use a lifting beam correctly adjusted to fit the unit (recommended). Roof Curb Installation Roof curbs are available as an accessory for “downflow” units to support the unit and ensure the water tightness between the rooftop and the roof. Four types of roofcurbs are available: the standard version to allow the installation of the unit on a flat roof with different return flow patterns (return roofcurb down, return roofcurb horizontal, multidirectional roofcurb) and the adjustable version for a slope roof installation (adjustable roofcurb down). The roofcurb characteristic is given in roofcurb submittal drawings sent with the unit. Figure 2 - Roofcurb down The units are supplied on the truck but are not unloaded. A lifting lug is provided on each corner of the unit’s base to facilitate handling. 4 shackles and 4 slings are required. Use a lifting beam to prevent the cables pressing too hard on top of the unit during lifting. Important: For unit to fit on the roof curb the wooden blocks must be removed. Lifting and moving Instructions Specific lifting method is recommended as follows: 1 - The units are supplied with four lifting points 2 - Slings and spreader bar to be provided by rigger and attached to the four lifting points. 3 - Minimum rated lifting capacity (vertical) of each sling and spreader bar shall be no less than the unit shipping weight. 4 - Caution: The unit must be lifted with the utmost care. Avoid shock load by lifting slowly and evenly. 5 - Remove slings and spreader bars when installation is completed. Figure 3 - Roofcurb multidirectional assembly The detailed handling, lifting instructions including all weights and sling lengths are given on the specific drawings and instructions shipped with the unit. RT-SVX056D-GB 19 Installation Instructions for the roofcurb assembly and installation with curb dimensions are provided with each roofcurb kit. In order to insure watertighness of the roofcurb assembly, it is important to respect the schematics below and to consult the booklet for roofcurb assembly shipped with the roofcurb module. Be sure that gasket is positioned on the roofcurb and without damage before unit positioning. To avoid any property damage or personal injury, it is the installer’s responsibility to make sure that the installation will not impair the function of this curb, or the unit to be installed; and that the roofcurb and unit must be completely sealed, preventing any water or air leakage damage. Installing the Unit The structure accommodating the unit(s) must be designed to support the equipment in operation, as a minimum. Refer to submittals drawings supplied with the unit for dimensions, weight and clearance requirement around unit. Unit support Install the unit on a flat foundation strong enough to support unit loading and level (within 5 mm across the length and width of the unit).If the unit is to be roof mounted check the building codes for weight distribution requirements Location and clearances Choose a location that will enable air to circulate freely in the condenser coil and allow air to be discharged above the fans. The clearance distances for air circulation and maintenance are indicated in the submittals drawings. Figure 4 - Waterproofing 4 Placing and rigging The rooftop units are designed to be installed outdoor and must be positioned horizontally (vertical air discharge off the condenser). 3 1 Slab mount 2 For ground level installation, the unit base should be adequately supported and hold the unit near level. In areas where snowfall is common, the unit must be elevated enough to ensure that the bottom of the outdoor coil is above the height of the expected snow accumulation. 1. 2. 3. 4. Roofcurb Roof membrane Seal Rooftop Where severely cold temperatures are a consideration, elevation of the unit is again recommended to ensure that defrost water does not create an ice build up that will interfere with unit operation. In addition, runoff water from roofs, etc... must not be allowed to fall on the outdoor coil; any blockage of airflow through the coil can be detrimental to unit operation and reliability. The manufacturer suggests that the bottom of the outdoor coil be raised 30cm above grade or roof to prevent possible ice build-up problems. The unit frame structure is not designed to be supported by four points (mounting on spring isolators for instance). The unit must therefore rest on its whole base. 20 RT-SVX056D-GB Installation Unit overall view Figure 5 - Indoor section Embedded control solutions Trane controller with embedded energy saving functionalities. Centralized control panel for easy access and service. Remote service terminal provided as an option. EC Plug Fan Compact, quiet and more efficient compared to traditional axial fans. Rail system for easy access and maintenance. Double skin panel Double wall and thick glass wool insulation provided as standard with all units, for higher indoor air quality. Sloped drain pan Non-corrosive sloped drain for improved condensate management, thus preventing formation of microbial agents that lead to poor air quality. Epoxy coating High quality Epoxy coating on fin & tube heat exchanger prevents corrosion and extends unit lifetime Fresh air hood Foldable for easy transportation and installation High Quality Air Filtration Two rails for wide range of filtration up to F9, capable of meeting local regulations Economizer with intelligent control Provided as standard with the every Airfinity™ unit, the economizer permits free cooling when conditions are favorable, saving up to 20% on annual energy consumption. Figure 6 - Outdoor section for AFD Unit Drive Box . Drive: compact and paired with the compressor. RFI filters: proposed as an option to achieve certain EMC emission level. Cooling fan: located down behind the front panel to ensure proper drive cooling. Grids with filters: located behind the grids to ensure clear air entering. High efficiency scroll compressor Delivers high performance in part load thanks to capacity modulation. RT-SVX056D-GB Easy- access panels Can be removed eassily using a common turnkey (no screws!). Prevents corrosion and missing components after service. 21 Installation Dimensions/Weights and Clearance Attaching horizontal ductwork to unit This information is supplied in the document package shipped with the unit. -A ll conditioned air ductwork should be insulated to minimize heating and cooling duct losses. Use minimum of 5cm of insulation with a vapor barrier. The outside ductwork must be weather proofed between the unit and the building. Connection of Duct Network Supply and return openings have curb flanges provided for easy duct installation. It is recommended to insulate the circumference of the curb after the unit is mounted to prevent condensation. CAUTION! All ductwork must be run and attached to the curb flanges before the unit is set into place. Guidelines for ductwork construction - Connections to the unit should be made with 7.5cm canvas connectors to minimize noise and vibration transmission. - Elbows with turning vanes or splitters recommended to minimize air noise and resistance. - The first elbow in the ductwork leaving the unit should be no closer than 60cm from the unit, to minimize noise and resistance. Figure 7 - Supplied trap 1 3 -W hen attaching ductwork to a horizontal unit, provide a flexible watertight connection to prevent noise transmission from the unit to the ducts. The flexible connection must be indoors and made out of heavy canvas. Note: Do not draw the canvas taut between the solid ducts. Condensate Drain Piping Each unit is equipped with a diameter 35 mm male drainage connector. A P trap is supplied and must be connected to the drainage as shown in Figure 7. Slope the drainage pipe down at least 1% to ensure an adequate condensate flow. Check all the condensate drainage pipe fittings comply with the applicable construction regulations and waste disposal standards. Figure 8 - Drain piping location 1:1Unit : unitdrain drain pan pan 2:2:ERC pan ERC drain drain pan 3:3Modulating : Modulating burner burner ½condensates ’’ drain connection 2 210 57 130 110 1. Panel enclosure 2. Atmosphere pressure 3. Static drain 3 22 1 2 RT-SVX056D-GB Installation Filter installation Figure 10 - Hot water coil Pressure Drop Access to the filter cells is done via the filter access door. Filter support can be slided laterally. Hot Water Coil Pressure Drop 300.0 Each unit is shipped with this available filter combination: 250.0 G4 Pressure (Pa) G4+F7 G4+F9 F5+F7 F7+F9 combination is not allowed 200.0 150.0 Size 21-71 100.0 Size 74-130 50.0 The number and the size of the filter cells are determined by the frame of the unit. Each unit has 2 rails of filter. 0.0 0 5000 10000 15000 20000 25000 30000 Airflow (m3/h) per rail Figure 11 - Electrical heater coil Pressure Drop Frame 1: 6 filters of 500x625 Electrical Heater coil pr. drop Frame 2: 8 filters of 500x625 60.0 Frame 3: 12 filters of 500x500 There is 3 different types of filters which are place on rails of 50 mm or 100 mm upstream of the indoor coil. Figure 9 - Filter Pressure Drop G4 - Frame 1 250.0 G4 - Frame 2 G4 - Frame 3 30.0 Size 74-130 20.0 Size 21-71 0.0 0 5000 10000 15000 20000 25000 30000 Aiflow m3/h G4+F7 - Frame 1 200.0 G4+F7 - Frame 2 G4+F7 - Frame 3 Pressure drop [Pa] 40.0 10.0 Clean Filter Pressure Drop G4+F9 - Frame 1 150.0 G4+F9 - Frame 2 G4+F9 - Frame 3 100.0 F5+F7 - Frame 1 F5+F7 - Frame 2 F5+F7 - Frame 3 50.0 0.0 Pressure (Pa) 50.0 0 5000 10000 15000 20000 25000 30000 Airflow [m³/h] Supply plug fan airflow adjustment 1)Order write up (OWU) indicate design airflow, supply and design air pressure drop. 2)Verify on site supply fan airflow. It should match OWU design airflow. 3)If on site airflow is different from OWU design airflow the actual supply and design air pressure drop should be different from design values, Trane service technician should be mandated to perform air flow adjustment and optimization. Recommended clog filter switch delta pressure value is 200 Pa with a maximum of 250 Pa according to available static pressure. RT-SVX056D-GB 23 Installation Supply fan Airflow measurement option The airflow measurement option when selected is associated with an air differential pressure sensor which measures the pressure difference before the inlet nozzle and inside the inlet nozzle. Unit air flow can be calculated on the basis of the differential pressure (difference in pressure of the static pressures) in keeping with the following equation: Qv in [m3/h] and ∆p in [Pa] N number of fans k takes into account the specific nozzle characteristics. Connection on the unit side is accomplished via a premounted T tube connector. This tube connector is suited for pneumatic hoses with an internal diameter of 4 mm. It is recommended to install one expansion valve as close as possible to each installed unit. The piping must be self-supporting before the final branch connection to the unit. Allow for a dust trap (filter) upstream of the connection to the unit. Search for gas pipe leaks using tensio-active product such as “Teepol” or “1000 bulles” or another equivalent method. Soapy water must not be used. WARNING! Never use a flame to search for leaks. The required gas pressures at the unit’s inlet connection are specified in table «Marking Category of gas section in different countries» CAUTION! The piping must not exert any stress on the branch connection to the burner. The heating system must be isolated by the gas stop valve on the gas supply piping during the pressure tests, as soon as the pressure exceeds 0.060 bar (60 mbar). If pressure greater than 0.060 bar is applied to the gas valve inlet the unit may be damaged. In this case it is mandatory to add a pressure reducer. Connect condensation pipe for modulating burner. 2 stages burner is not supposed produce condensate and the small amount of condensate possibly produced in particular working conditions will in case evaporate Figure 12 - Typical Gas Supply pipework k factors: Fan diameter 400 450 500 k-factor 188 240 281 KEY According to the option chosen, airflow or fan RPM can be read directly on the optional display or should be determined by connecting a pressure drop meter to the pre mounted T connector. Setup is -20%/+30% variation versus factory setting (190m3h-1/kW @ 250 Pa). Gas Pipework Installation 1 2 3 4 5 6 7 8 Main burner gas solenoid valve Pilot burner gas solenoid valve Pressure stabiliser Safety gas solenoid valve Gas filter (small section) Anti-vibration joint Gas filter (large section) Gas valve Installation of gas piping (to be performed by the contractor) The installation rules for public buildings shall be followed: refer to the brochure in the “Journal Officiel” number 1477-1 (France only). The gas supply piping and the gas stop valve shall be dimensioned to guarantee the gas supply pressure at the unit’s inlet when it is functioning at full capacity. 24 RT-SVX056D-GB Installation WARNING Hazardous Voltage! If pressure is higher than 60mbar, a presure reducer must be installed at a distance of at least 10m and no pressure stabiliser must be fitted between the pressure reducer and the heater, but leaving the gas filter. Disconnect all electric power, including remote disconnects before servicing. Follow proper lockout/ tagout procedures to ensure the power can not be inadvertently energized. Failure to disconnect power before servicing could result in death or serious injury. Important! 10m During the installation, we recommend to tighten the nut fastening the external gas supply pipe without exceeding the tightening torques shown below: - Ø 3/4’’: 150 Nm; Do not allow conduit to interfere with other components, structural members or equipment. Control voltage (230 V) wiring in conduit must be separate from conduit carrying low voltage (<30V) wiring. To prevent control malfunctions, do not run low voltage wiring (<30V) in conduit with conductors carrying more than 30 volts. Smoke outlet features CAUTION! Unit is shipped with an outlet adaptor for connection to exhaust pipe. If there is no exhaust pipe used, a terminal feature located on the accessories should be installed. Inverters are equipped with integrated filters. They are not compatible with insulated neutral load earthing arrangements. Note: Exhaust pipe material has to be chosen carefully to avoid corrosion. WARNING! Hazardous Voltage with Capacitor! Max 60 mbar Pressure reducer Figure 13 - Exhaust gas terminal installation 1: Exhaust pipe adaptor with gasket 2: Terminal parts installation General Electrical Recommendations Electrical Parts When reviewing this manual keep in mind. - All field-installed wiring must be in accordance with local regulations, CE directives and guidelines. Be sure to satisfy proper equipment grounding requirements according CE - The following standardized values - Maximum Amps Short Circuit Amps - Starting Amps are displayed on unit nameplate. - All field-installed wiring must be checked for proper terminations, and for possible shorts or grounds. Note: always refer to wiring diagrams shipped with unit or unit submittal for specific electrical schematic and connection information. RT-SVX056D-GB Disconnect all electric power, including remote disconnects and discharge all motor start/run and AFD (Adaptive Frequency TM Drive) capacitors before servicing. Follow proper lockout/tagout procedures to ensure the power cannot be inadvertently energized. Any contact with electric components, even after the unit has been switched off, can cause serious injury or death. Wait at least 5 minutes after switching off the unit, until the current dissipates. • For variable frequency drives or other energy storing components provided by Trane or others, refer to the appropriate manufacturer’s literature for allowable waiting periods for discharges capacitors. Verify with an appropriate voltmeter that all capacitors have discharged. • DC bus capacitors retain hazardous voltages after input power has been disconnected. Follow proper lockout/ tagout procedures to ensure the power cannot be inadvertently energized After disconnecting input power, wait five (5) minutes for units which are equipped with EC fans and wait twenty (20) minutes for units which are equipped with variable frequency drive (0V DC) before touching any internal components. Failure to follow these instructions could result death or serious injury. Installer-Supplied Components Customer wiring interface connections are shown in the electrical schematics and connection diagrams that are shipped with the unit. The installer must provide the following components if not ordered ith the unit: • Power supply wiring (in conduit) for all field-wired connections. • A ll control (interconnecting) wiring (in conduit) for field supplied devices. • Circuit breakers. 25 Installation Grounding Be sure to ground the unit and differential protection should be suited for industrial machinery with current leak which can be higher than 300 mA (several motors and frequency drives). Figure 14 - Supply Power wiring layout to avoid hot areas CAUTION! To avoid corrosion, overheating or general damage, at terminal connections of power supply wiring, unit is designed for copper mono-conductors only. In case of multiconductor cable, an intermediate connection box must be added. For cable with alternative material, bi-material connecting devices are mandatory. Cable routing inside control panel should be made case by case by installer. WARNING Ground Wire! All field-installed wiring must be completed by qualified personnel. All field-installed wiring must comply with local codes and regulations. Failure to follow this instruction could result in death or serious injury. All power supply wiring must be sized and selected accordingly by the project engineer in accordance with local codes and regulations. Example of wiring layout of supply power to avoid hot area WARNING! The Warning Label which is displayed on the equipment and shown on wiring diagrams and schematics. Strict adherence to these warnings must be observed. Failure to do so may result in personal injury or death. CAUTION! After completion of wiring, check all electrical connections, and ensure all connections are tight. Replace and secure all electrical box covers and access doors before leaving unit or connecting power to circuit supplying unit. CAUTION! Units must not be linked to the neutral wiring of the installation. Units are compatible with the following neutral operating conditions: Scroll compressors TNS IT TNC TT Standard** Special Special Standard* * Differential protection should be suited for industrial machinery with current leak which can be higher than 300 mA (several motors and frequency drives). Neutral wire not distributed. ** Neutral wire not distributed Electrical Connections The electric panel is located on the length of the indoor section behind the plug fan section. The unit is designed to run with 400V (+/-10%) - 50 Hz (+/-1%) - 3 ph. 2 glands are available on each unit to be able to connect the unit to the main supply either from the side or from the bottom. CAUTION! Be sure that layout of electrical conduit is remote enough from hot components (burner, electrical heater...). 26 Proper phasing of the electrical power wiring is critical for proper operation and reliability of the scroll compressor and fans. Proper rotation of the scroll compressor must be established before the unit is started. This is accomplished by confirming that the electrical phase sequence of the power supply is correct. The motor is internally connected for clockwise rotation with the inlet power supply phased A, B, C. The direction of rotation may be reversed by interchanging any two of the line wires. It is this possible interchange of wiring that makes a phase sequence indicator necessary if the operator is to quickly determine the phase rotation of the compressor motor. The “ABC” indicator on the face of the phase indicator will glow if phase is ABC for terminals L1, L2, and L3. Oil Injection Valve: This is specific for Scroll compressor with variable frequency drive (VFD). Compressor drive: In case of replacement, configuration will be done by Trane service. There is no human interface and the configuration is done via RS485 Modbus. Drive cabinet is cooled by a fan on the bottom behind the door. Air entering from the bottom through a grid with filter and leaving from the top through a grid with filter. Filter maintenance: clean or change the drive filters if necessary. RT-SVX056D-GB Operating Map Cooling mode Operating map at cooling mode Operating map of cooling mode Ambient temperature (°C) 50 45 40 35 30 25 20 15 10 5 0 -5 -10 -15 -20 Low ambient Maximum Outdoor Temperature (@ Eurovent) = 46°C Minimum Outdoor Temperature = -15°C Maximum Indoor Coil Entering Temperature = 35°C Minimum indoor Coil Entering Temperature = 15°C Standard ambient Low ambient 10 15 20 25 30 Return air mix temperature (°C) 35 40 Heating mode Operating map at heating mode Operating map of heating mode Maximum Outdoor Temperature (@ Eurovent) = 20°C Minimum Outdoor Temperature = -15°C Maximum Indoor Coil Entering Temperature = 26°C Minimum indoor Coil Entering Temperature = 5°C Ambient temperature (°C) 25 20 15 10 5 0 -5 -10 -15 -20 0 5 10 15 20 Return air mix temperature (°C) 25 30 ERC Cooling mode Operating map - cooling mode 35 Return air temperature (°C) Minimum Return Air Mix Temperature = 18°C Maximum Return Air Mix Temperature = 33°C Minimum Return Air Temperature = 20°C Maximum Return Air Temperature = 31°C 30 25 20 15 15 RT-SVX056D-GB 17 19 21 23 25 27 29 Return air mix temperature (°C) 31 33 35 27 Operating Map ERC Heating mode Operating map - heating mode 25 Return air temperature (°C) Minimum Return Air Mix Temperature = 18°C Maximum Return Air Mix Temperature = 24°C Minimum Return Air Temperature = 10°C Maximum Retrun Air Temperature = 26°C 20 15 5 10 15 20 Return air mix temperature (°C) 25 30 Auxillary Heating mode Ambient temperature (°C) Operating map of an auxiliary heater 28 25 20 15 10 5 0 -5 -10 -15 -20 -25 Operating map of an auxiliary heater Maximum Outdoor Temperature (@ Eurovent) = 20°C Minimum Outdoor Temperature = -20°C Maximum Indoor Coil Entering Temperature = 26°C Minimum indoor Coil Entering Temperature = 5°C 0 5 10 15 20 Return air mix temperature (°C) 25 30 RT-SVX056D-GB Options Free cooling economizer unit is supplied with economizer and fresh air hood as a standard feature. Fresh air percentage can vary from 0 to 100%. An economizer consists of: • A motorized damper with separate fresh air and return air sections. • A fresh air hood with a grill delivered folded in the unit. • All necessary sensors for free cooling operation. The mechanical opening of the damper is managed by the actuator which is adjusted by Trane controller. Damper is activated in free cooling mode and may be further controlled by temperature control with return and outdoor air sensors or by enthalpy control with addition to temperature sensor of return and outdoor humidity sensor. Building Pressurization Control Barometric Relief The barometric relief allows to minimize overpressure in the building caused by the introduction of fresh air. This option is typically installed when fresh air intake is below 25% of the nominal air flow and when the return air pressure drop is below 25Pa. Barometric damper is available as option into economizer option on downflow and not compatible with heat recovery module unit only. When the pressure of the building increase, the dampers open and relieve air to the outside. If the return air duct pressure drop is higher than the building overpressure, the dampers will not open. Fresh air hood installation If the return air duct pressure drop is lower than the building overpressure, the dampers will open and relieve air outside of the building. Figure 15 - Fresh air hood assembly steps Figure 16 - Barometric relief Step 1 Step 2: Position side flange with corner on the outside Step 3: lift up the hood vertically to insert it Step 4 Caution: In case of ERC, installation of ERC module has to be made prior to fresh air hood. RT-SVX056D-GB 29 Options Exhaust Fans The exhaust axial fans are used to minimize the overpressure in the building caused by the introduction of fresh air. This option is typically used when the fresh air intake needed is between 40 to 50% of the nominal air flow or when the return air duct pressure drop is higher than 25Pa (<70Pa or 150Pa according to option selected). This option includes hoods, gravity dampers and axial fans. Optional service Terminal allow to adjust exhaust fans start and stop value according to fresh air damper position. When the supply air fan is ON, the exhaust fans turn on whenever the position of the fresh air dampers meet or exceed the exhaust fan set point. (If the potentiometer is set at 40%, the exhaust fans will start when the fresh air dampers will meet or exceed 40% opening). Configured for Return roofcurb (ESP=250 PA) 2 types of return roofcurbs modules have been developped (downflow and horizontal flow) in order to minimize overpressure in the buildng caused by the introduction of fresh air when there is a significant pressure drop in the return duct (250 Pa maximum) and when supply fan is not enough to overcome both supply and return external static pressure. The module is fully controlled and powered by the rooftop control. The assembly detail is given in the submittal shipped with the document package sent with the unit. Figure 18 - Return roofcurb downflow Operation • When the exhaust fans are OFF : - The barometric dampers open when the air pressure inside the building increases. As the building pressure increases, the pressure in the unit return section also increases, opening the dampers and relieving the air. - If return air pressure drop>building overpressure (∆P>Pb – Patm) → barometric damper is closed. - If return air pressure drop<building overpressure (∆P< Pb – Patm) → barometric damper opens and a maximum of 25% of the nominal airflow can be exhausted. Figure 19 - Return roofcurb horizontal flow • When the exhaust fans turn ON : - Around 50% of airflow can be exhausted, depending on the pressure drop in the return air duct. - The two fans work always together, on stage ON-OFF. - Each fan has two speeds, which makes 2 configurable speeds by changing the wiring on site. - The exhaust fan is started when fresh air dampers meet or exceed a preset percentage of fresh air. Configured for Return roofcurb (ESP=250 PA) Figure 17 - Exhaust fan Exhaust Fan EC The exhaust fans EC are used to minimize overpressure in the building caused by the introduction of fresh air. This option is typically used when large fresh air intake needed (40 to 50% of the nominal airflow) or when the return air duct pressure drop is higher than 70Pa. This option includes hoods, gravity dampers and EC Exhaust fans. Exhaust fans speed has to be adjusted during the commissioning using the optional service Terminal to balance building pressure. 30 RT-SVX056D-GB Options Installation: • The Exhaust fan module is delivered dismounted on the same pallet than the main unit. (See fig ….) • The Exhaust module as to be installed on the exhaust section. (See fig…) • The exhaust module electrical wiring has to be connected to the main unit. (See fig) Exhaust fan speed setting: • Step 1 : adjust the unit fan speed @ the nominal flow rate using the optional service terminal. • Step 2 : adjust the exhaust fans speed using optional service terminal to reach right amount of exhaust air. Table 5 - Ethylene glycol percentage Ethylene glycol percentage Freezing point (%) (°C) 10 -4 20 -10 Water connections dimensions and characteristics Figure 21 - Hot water coil view and connections Outlet Inlet Hot Water Coil (HWC) Water inlet/outlet connection 1”1/2 ISO 228/1 Figure 20 - Hot water coil location in the unit The hot water coil is factory mounted and placed in the discharge section. Two holes are provided to connect the hot water coil. The tubes for entering and leaving water are equipped with a threaded female connection. Figure 22 Hot Water Coil Pressure Drop Pa 160 140 120 100 HW2 80 60 HWC applies when additional heat is required. Hot water comes from external boiler or other device. HWC provides heating with a coil located after the indoor coil and offer full modulation heating control through the use of a 3 ways valve. Control is based on mixed air temperature and zone temperature. Factory setting is given to heat pump operation. Hot water is called in addition. Priority can be switched on site. Antifreeze protection opens the 3 ways valve when the coil temperature is closed to the freezing point (2°C). In antifreeze mode, unit operating, indoor fan is stopped and unit locked out in manual reset. Fresh air damper is closed and the modulating valves open. The freeze protection works with manual reset. Important notice: it is important that the pump circulating hot water is permanently working to avoid water to freeze in the coil. Otherwise, in order to prevent water from freezing in the coil during unoccupied period or shutdown limited period, it is recommended to use ethylene glycol. The service of a water treatment specialist is recommended as water used can cause scaling deposits, erosion or corrosion. Insulate and proceed to heater wire installation on all the water piping likely to be exposed to freezing temperatures in order to avoid freeze up of the coil and heat losses. The water distribution network must be fitted with vents in places where air is likely to be trapped. RT-SVX056D-GB 40 HW1 20 0 0 1 2 3 4 5 6 7 8 9 10 m3/h Electric Heater Electric heaters are fitted on the supply fan discharge. Heaters have two heating stages and provided with two types of overheat thermostats: • Automatic reset thermostats which stop the electric heater when the air temperature rises to 65°C. Automatic reset at 32°C. • The manual reset thermostat which stops the unit when the air temperature rises to 128°C. Figure 23 - Heater onto unit and heater detail 31 Options Heat Recovery Module Figure 24 Energy Recovery Module is a module that transfers heat (cool or warm) from exhaust air to fresh air. It is an addon module that includes a heat exchanger, exhaust fan, filters and dampers, heat exchanger: rotary wheel. The module is shipped separately and connected to the rooftop on jobsite The module is fully controlled and powered by the rooftop itself. Free cooling mode is still available. Assembly of the module should be done according to the below instructions and with the help of submittal and electrical drawings shipped with the unit. Figure 25 32 RT-SVX056D-GB Options Figure 26 Figure 27 Figure 28 RT-SVX056D-GB 33 Options Figure 29 Figure 30 Figure 31 34 RT-SVX056D-GB Options Figure 32 Figure 33 Figure 34 Electrical wiring of ERM module to the unit RT-SVX056D-GB 35 Options Burner module Figure 37 - Cooling mode COOLING MODE PCH : premix burner with a condensing heat exchanger Figure 35 - Modulating (PCH) gas valves and variable speed combustion blower FRESH AIR HX + combustion chamber 100% stainless steel EXHAUST AIR Flue gas outlet Condensate water Drain pipe on PCH not on PRH Natural Gas (G20 / G25) Or LPG (G31) RETURN AIR SUPPLY AIR Air Modulating (PCH) or staged (PRH) gas valves & variable speed combustion blower Energy Recovery Circuit (ERC) « Exhaust » coil (Condenser) « Recovery » coil (Evaporator) The ERC consists of an additional refrigeration circuit which recovers the energy in the exhaust air to preheat or pre-cooled the fresh air. The ERC includes a compressor, heat exchanger coils and exhaust fan. Cold air coming form the building causes refrigerant condensation in the “Exhaust” coil, then refrigerant is expanded and conveyed to “Recovery” coil. Mix air is precooled through refrigerant evaporation in “Recovery” coil. Figure 36 - Heating mode Figure 38 - Thermodynamic heat recovery HEATING MODE «Recovery» Coil «Exhaust» Coil Filter/Drier FRESH AIR Barometric Dampers EXHAUST AIR 4 Way Valve Exhaust Fans TXV (Thermostatic eXpansion Valve) SUPPLY AIR RETURN AIR « Recovery » coil (Condenser) « Exhaust » coil (Evaporator) Hot air coming from the building causes refrigerant evaporation in the “exhaust” coil. Then refrigerant is compressed and conveyed to “Recovery “ coil and mix air is preheated through refrigerant condensation in “Recovery” coil. 36 HP switch HP/LP sensor Compressor Assembly procedure of fan block All ERC specific electrical components are located in the electrical box. Electrical connections of exhaust fan must be performed on site. RT-SVX056D-GB Options ERC fan module installation The module is screwed on the main unit pallet Figure 39 - ERC Installation process 8) Install the Weather hood is mounted once the unit is installed on the roof 7) Screw the module to the unit 2) Lift module using dedicated lifting lugs 9) Plug in the exhaust fans’ connector through the dedicated hand hole 1) Unscrew module from pallet Modulating (PCH) gas valves & variable speed combustion blower 4) Approach module to the exhaust section of the unit 3) Apply sealings to the box frame 5) Handle shaped frame helps positioning of the module 6) Position the module on the dedicated support rail RT-SVX056D-GB 37 Controls CH536 + module extension Service Terminal Control Hardware Modules The service terminal is an option to the customer, easily plugged to unit through cable. The controller is composed of six different buttons and a graphical display. This view of plug-and-play service and the controller allows personal service to read and modify some parameters of the device as setpoints (cooling and heating), airflow, alarm and warning display. The main CH536 module allows the control of the heat pump, the indoor EC fan and the outdoor fan. 3 extension module can be used : - 1 module for auxiliary heat, economizer enthalpy, exhaust fan and for ERP. - 1 module for heat recovery. - 1 extension module to manage customer options. Figure 40 - CH536 main module It includes scrolling menus and explanation of full text. Figure 42 - Optional display Alarm Prog Esc Up Enter Down Control Hardware Bus This diagram is for information. For details refer to wiring diagram shipped with the unit. Figure 41 - Control Hardware Bus 38 RT-SVX056D-GB Controls Zone temperature source CO2 sensor maintenance The zone temperature source are summarized in the table below by hierarchy order. This CO2 sensor has excellent stability and requires no maintenance. In most environments the recommended calibration interval is five years. A trained service technician can use a portable CO2 meter to certify sensor calibration. If, when checking the sensor, the reading differs too much from the reference value, the sensor can be recalibrated in the field. A calibration kit, software, and calibration gases are required. If certified accuracy is required, the sensor must be calibrated against accurate and traceable calibration gases in a laboratory. Consult Trane BAS for further details. Source Condition 1. BAS BAS command enabled & Value in validity range [-10°C; +50°C] 2. Zone Temp Sensor Ad-hoc Config enabled & Value in validity range [-10°C; +50°C] 3. Zone Temp THS04 THS04 installed & Ad-hoc Config enabled & Value in validity range [-10°C; +50°C] 4. Conventional Thermostat Ad-hoc config enabled 4. Return Air Temp Value in validity range [-10°C; +50°C] Fire thermostat U12 is the dedicated I/O. Optional fire thermostat should be configured if present according to wiring diagram. CO2 sensor Clogged filter detector CO2 sensor can be either in air return duct or wall mounted. It maintains a CO2 concentration below a preset value to ensure acceptable comfort. This device is mounted in the filter section. The sensor measures the difference in pressure before and after the filter section. The information is sent to the optional service terminal or the BMS. Controls the opening of the fresh air damper of the economizer. The outside air damper will modulate in order to maintain the CO2 concentration below the setpoint. To open damper it should combine the amount of desired fresh air and the free cooling mode to modulate from 0 to 100% maximum opening of the dampers. It is possible to preset a minimum opening during commissioning. The CO2 sensor is set for 0-10V analog outputs and provide sensing of carbone dioxide over a range of 0-2000 ppm. The sensor requires a 24 VDC power supply. Consult wiring diagram supplied with the unit for details. The resolution of analog outputs reaches 10 ppm CO2. The information is then sent to the controller CH536 to control the opening position of the fresh air damper. Avoid locating the duct sensor on surfaces with an uncooled, unheated area behind them or in “dead” spot behind doors or in corners. The CO2 wall mounted sensor should be placed on a flat surface, 1.4 m from the floor in an area of the room where there is free air circulation. Smoke Detector This device is used to detect smoke in the air stream. It includes a factory mounted detector located in the control panel. When smoke is detected, it shuts off the unit. Other accessories available -D TS : duct mounted wired temperature sensor The duct mounted sensor - mainly for unit with auxliary heat - must be installed away of any duct singularities and generally at 2 m of any duct elbow or duct inside element both upstream and downstream. -T ZS01 : wall mounted wired temperature sensor -T HP05 : wall mounted thermostat Refer to separate documentation for more information. Alarm and Warnings Alarms stop the unit or reduce the heating/cooling capacity. Alarm can be either manual reset (requires human intervention to re-start the unit) or automatic reset. Warning run the unit in fall-back mode. Example : if outdoor air humidity sensor is not working, the economizer runs in dry-bulb mode. Events are accessible through optional local service terminal which display the current events and display history of past events (up to 99 alarms and 99 warnings). RT-SVX056D-GB 39 Customer option module Operation with a conventional thermostat For Customer option module refer to wiring diagram supplied with the unit for detailed information. Customer option module For unit with variable speed controller: Input/Output are defined with the optional service terminal. Outputs are only with dry contacts. Mechanical cooling command compressor start and stop use CMP1 input List of I/Os through universal pins Mechanical heating command compressor start and stop use CMP1+O Emergency Stop External Auto / Off Takes precedence over THP05 Circuit1 Disable In both modes, the modulation of the compressor speed will be automatically adjusted based on return air temperature measure and cooling/heating setpoint. Circuit2 Disable Compressor 1A Disable Compressor 1B Disable Compressor 2A Disable CMP1 W1 CMP2 W2 Y1 Compressor 2B Disable CpCOe Occupancy Sensor Customer options Timed Override occupied initiate Y2 O X2 G Timed Override occupied terminate • C1 = Call for one compressor Aux. Heat Disable External Control (Digital In) O Unit Electrical Box Mech to Aux Heating changeover • C3 = Call for one compressor • C2 = Call for one compressor • C4 = Call for one compressor • O = Switchover Valve (On=cooling ; Off=Heating (HP)) Pressurize override • X1 = Call for Aux. Heat 1 Purge override • X2 = Call for Aux. Heat 2 • G = Call for supply fan Exhaust override • F = 0 – 10V signal to control supply fan speed Conventional Thermostat • R = 24VAC power to thermostat CMP2 * Conventional Thermostat For overall wiring, consult wiring diagram supplied with the unit. CMP3 * Conventional Thermostat CMP4 * Conventional Thermostat SOV * Conventional Thermostat AuxHeat1 * Conventional Thermostat AuxHeat2 * Conventional Thermostat IDFan * Conventional Thermostat open = OFF / closed = ON CMP1 * Active Unit Mode Conv Th O control OFF Inactive - Auto Active enabled Heat Active disabled Cool Active disabled Firestat The main module should be configured with the appropriate I/O. 40 RT-SVX056D-GB Customer option module Economizer control Opening Airflow Damper Demand Control Ventilation The mechanical opening of the damper is managed by the actuator which is adjusted by Trane controller. In Free cooling mode, fresh air flow can be adjusted thru optional terminal but the maximum opening airflow damper minimum position is set at 50% by default and maximum factory setting is 95%. At installation, Minimum Fresh Air Percentage during occupied time have to be adjusted. The 10 I/O for economizer allow 4 strategies for Demand control ventilation #1: Fixed Ventilation (design ventilation) It is based on design occupancy of the zone. Occupied standby setpoint = 0.6L/s per m2 (ASHRAE62.1) x Surface Occupied setpoint = 4.72L/s per person (ASHRAE62.1) x DesignOccupants# + Occupied standby setpoint #2: Occupancy-based ventilation – requires an occupancy sensor During occupied hours, depending on occupancy sensor, we can switch between 2 setpoints no people detected: Occupied Standby Setpoint = 0.6L/s per m2 x Surface people detected: Occupied Setpoint = 4.72L/s per person x DesignOccupants# + Occupied Standby Setpoint #3: CO2-based ventilation – requires a space CO2 level information (sensor or BAS) Modulates between Occupied setpoint and Occupied Standby setpoint with Damper control. Emergency Ventilation override Three possible external requests, with following priority order 1. Pressurize 2. Purge 3. Exhaust When those override modes are activated, heating or cooling are turned OFF. If they were ON, the emergency stop mode is used. Those override modes can be activated through local request or BAS. Emergency override command: 1. 2. 3. 4. 5. 6. Normal Pressurize Depressurize Purge Shutdown Fire Table 6 - Override mode Override mode Pressurize Purge Exhaust (Depressurize) Smoke Detector Shutdown (Emergency Stop/ Firestat) ID Fan ON - Full Speed ON - Full Speed OFF OFF OFF OA Damper Open 100% Open 100% Close 0% Open 100% Close 0% Exhaust Fan OFF ON ON OFF OFF Heat/Cool OFF OFF OFF OFF OFF RT-SVX056D-GB 41 Operation Test Procedures Operating pressures Operating checklist before start-up • Review submittals for rooftop and accessories as well as main wiring diagrams and options shipped with the unit • Unit is level, with sufficient clearance all round • Duct network is correctly sized according to the unit configuration, insulated, and water-tight • Condensate drainage line is correctly sized, equipped with a trap, and sloped • Filters are in position, of correct size and quantity and clean • Wiring is correctly sized and connected in accordance with wiring diagrams • Power supply lines are protected by recommended fuses and correctly earthed • Thermostat is correctly wired and positioned • Unit is checked for refrigerant charge and leaks • Indoor and outdoor fans rotate freely and are fixed on shafts • Supply fan rotation speed is set • Access panels and doors are replaced to prevent air entering and risks of injury After the unit has operated in cooling mode for a short period of time, install pressure gauges on the gauge ports of the discharge and suction line valves. WARNING! If any operating checks must be performed with the unit operating, it is the technician’s responsibility to recognize any possible hazards and proceed in a safe manner. Failure to do so could result in severe personal injury or death due to electrical shock or contact with moving parts. Power-up initialization CAUTION! Before proceeding with any test procedure or operation, make sure that crankcase heaters have been energized for at least 8 hours. Starting the unit in cooling mode Before start-up, ensure that all power cables are tightened. Note: Always route refrigerant hoses through the port hole provided and ensure that the compressor access panel is in place. Final installation checklist • Are all power cables tightened? Check torque of power cables contact ! • Is the condenser fan and indoor blower operating correctly, i.e. correct rotation and without undue noise? • Are the compressors operating correctly and has the system been checked for leaks? • Have the voltage and running currents been checked to determine if they are within limits? • Have the air discharge grilles been adjusted to balance the system? • Has the ductwork been checked for air leaks and any condensation? • Has the air temperature rise been checked? • Has the indoor airflow been checked and adjusted if necessary? • Has the unit been checked for tubing and sheet metal rattles or any unusual noises? • Are all covers and panels in place and properly fastened? To keep the unit operating safely and efficiently, the manufacturer recommends that a qualified service technician check the entire system at least once each year, or more frequently if conditions warrant. Upon power initialization, the control performs selfdiagnostic checks to insure that all internal controls are functioning. It checks the configuration parameters against the components connected to the system. Verify that the unit airflow rate is adjusted. 42 RT-SVX056D-GB Operation Gas Burner first start The PCH burner are supplied with factory settings according to model number gas selection. They are tested for the gas specified on the burner nameplate. However it is required to - Check the gas category - Check the gas intake pressure on the gas valve -P erform the combustion analysis to verify that the level of flue gases corresponds to the data contained in general data table or in manufacturer IOM manual. Premix burner working cycle 1. H eat request signal coming from CH536 2. B urner fan starts to pre-wash combustion chamber 3. E V1 and EVP gas valves open to allow gas to feed pilot burner 4. S tart up electrode gives ignition sparks on pilot burner 5. E V2 main gas valve opens to gas feed main burner 6. C ombustion starts thanks to pilot flame ignition 7. P ilot and main burners work together for a shor time, then the electronic boards close EVP and stops the pilot Figure 44 - Premix burner of working cycle When turned on for the first time, the pilot burner may not ignite due to air kept in gas hose. There is the need to reset the equipment and repeat the operation until gas hose is purged and it ignites. Consult electrical drawing and supplier IOM shipped with the unit. Figure 43 - Example of PCH burner Interface panel Table 7 - Marking Category of gas section in different countries CATEGORY II2Esi3P II2H3B/P II2H3B/P II2HS3B/P II2L3B/P II2H3P I2E( S ) I2E( R ) II2ELwLs3B/P II2E3P II2ELL3B/P I3P I2H G20 G25 G31 25 37 FR mbar 20 DK, FI, GR, SE, NO, IT, CZ, EE, LT, SI, AL, MK, BG, RO, HR, TR mbar 20 - 30 AT, CH mbar 20 mbar 25 - 50 HU - - NL mbar - 25 30/37/50 ES, GB, IE, PT, SK mbar 20 - 37 BE < 70kW mbar 20 25 - BE > 70kW mbar 20 25 - PL mbar 20 - 37 PCH Red 3 digit LCD display Module status (rdy, On, Off, Fxx...) 3 levels menu: - I/O (Input/Output) - PAR (parameters) - Flt (Faults) ERC first start and control - C heck ERC compressor rotation P ower indoor fans and set to design supply air flow S et return roofcurb fans (if present) to design air flow P ower exhaust fans and check correct rotation. In both heating and cooling mode, ERC compressor has priority to start. -E RC compressor is not authorised to start when indoor air temperature is outside its operating map or fresh air rate is under 20%. -O utside operating conditions, ERC doesn’t start and unit control is as usual - When ERC becomes available its compressor gets loading priority. LU mbar 20 - 30/37/50 DE mbar 20 20 50 BE mbar - - 37 LV mbar RT-SVX056D-GB 20 - - 43 Maintenance End user Routine Maintenance Some of the periodic maintenance functions for the unit can be undertaken by the end user. This includes replacing (disposable) or cleaning (permanent) air filters, cleaning unit cabinet, cleaning the condenser coil, and carrying out a general unit inspection on a regular basis. WARNING! Disconnect the power supply before removing access panels to service the unit. Failure to disconnect power before attempting any servicing can result in severe injury or death. Air filters It is very important for the central duct system air filters and drive box filters to be kept clean. These should be inspected at least once a month when the system is in constant operation (in new buildings, the filters should be checked every week for the first four weeks). If disposable-type filters are used, they should only be replaced with ones of the same type and size. The economizer fresh air filter should be inspected (washed if needed) at least once a month. Note: Do not attempt to clean disposable filters. Permanent filters can be cleaned by washing with a mild detergent and water. Ensure that the filters are thoroughly dry before reinstalling them in the unit (or duct system). • • • Unit duct connections, to ensure they are physically sound and sealed to the unit casing Unit mounting support, to ensure that it is sound The unit, to ensure there is no obvious deterioration Before the heating season, your service technician may examine the following areas of your unit: • The unit, to ensure that the condenser coil can receive the required airflow (that the condenser fan grille is not obstructed) • The control panel wiring, to verify that all electrical connections are tight, and that wire insulation is intact Troubleshooting Alarm and Warnings The optional control display has the ability to provide the service personnel with some unit diagnostics and system status information. 1. Step the system through all of the available modes, and verify operation of all outputs, controls, and modes. If a problem in operation is noted in any mode, proceed to troubleshooting search. 2. Refer to the individual component test procedures if other microelectronic components are suspect. 3.In addition review carefully the components which can lead to the alarm: temperature sensor, zone temperature sensor, clogged filter switch Note: Replace permanent filters when required or at least annually if washing fails to clean them, or they show signs of deterioration. Be sure to use the same type and size as were originally installed. Condenser coil Unfiltered air circulates through the unit’s condenser coil and can cause the coil’s surface to become clogged with dust, dirt, etc. To clean the coil, brush the coil surface in the direction of the fins with a soft bristled brush. Keep all vegetation away from the condenser coil area. Hot water coil (option) Stop the unit. Do not disconnect the main supply to the unit. This will permit the anti-frost protection to continue to operate, and avoid water to freeze-up in the coil. Service Technician Maintenance Before the cooling season, your service technician may examine the following areas of your unit: • Filters, for cleaning or replacement • Motors and drives system components • Economizer gaskets, for replacement if necessary • Condenser coils, for cleaning • Safety controls, for mechanical cleaning • Electrical components and wiring, for replacement and tightening of connections as necessary • Condensate drain, for cleaning 44 RT-SVX056D-GB Recommended service routine frequencies As a commitment to our customers, we have created a wide service network staffed with experienced factory authorized technicians. At Trane we offer all the benefits of after sales service direct from the manufacturer and we are committed to our mission statement to provide efficient customer care. We would be delighted to discuss your individual requirement with you. For further information regarding Trane maintenance agreements please contact your local TRANE sales office. RECOMMENDED YEARLY SERVICE ROUTINE FREQUENCIES Year Commissioning 500 / 1000 hr Visit 1 X X Annual Maintenance Inspection Visit XX 2 X XXX 3 X XXX 4 X XXX 5 X XXX 6 X XXX 7 X XXX 8 X XXX 9 X XXX 10 X XXX +10 Every year 3 Every year This timetable is applicable to units operating in normal conditions with an average of 4000 hours per year. If operating conditions are abnormally severe, an individual timetable must be made for that unit. RT-SVX056D-GB 45 Maintenance routine Commissioning Annual Maintenance - - Check installation of equipment/pre-commission. Configure unit control module. Calibrate controls. Check operational set points and performance. Check operation of all safety devices. Megger the motor compressor windings. Check unit operation. Record operating temperatures pressures, amperages and voltage. - Carry out leak test. - Fill the start up log sheet and review with the operator. Gas Heat - Check operation of gas train components. Check burner sequence of operation. Check combustion blower assembly. Check gas pressure to unit. Inspect flame condition. Carry out flue gas analysis. Electric Heat - Inspect all electrical connections. - Verify correct operation of heating elements. Hot Water/Steam - Inspect valves and traps. - Verify operation of heating. 500/1000 hours visit - Visit at the end of running in period. - Replace compressor oil on all circuit’s. - Replace liquid line drier cores on each circuit (if applicable). - Carry out leak test. - Inspect contacts and tighten terminals. - Record operating pressures, amperages and voltage. - Check condition of evaporator & condenser coils. - Check operation of machines/compare conditions of operation against original commissioning data. - Fill out the 500/1000 hours visit log sheet and review with the operator. - Carry out flue gas analysis ( Gas Heating ). - Log book to be stamped validating 500/1000hr. visit. - C heck operational set points and performance. C alibrate controls. C heck operation of all safety devices. Inspect contacts & tighten terminals. M egger the motor compressor windings. R ecord operating pressures, amperages and voltage. C arry out leak test. C heck configuration of unit control module. R eplace line drier cores on each circuit (if applicable). C arry out system analysis. C hange the oil as required based upon results of the Trane laboratory analysis. L ubricate motors/dampers/bearings (where applicable). C heck condition of evaporator & condenser coils. C heck operation of machines/compare conditions of operation against original commissioning data. C omplete annual maintenance visit log sheet and review with the operator. Gas Heat - C heck operation of gas train components. C heck burner sequence of operation. C heck combustion blower assembly clean if required. C heck gas pressure to unit. Inspect flame condition. C arry out flue gas analysis. Electric Heat - Inspect all electrical connections. -V erify correct operation of heating elements. Hot Water/Steam - Inspect valves and traps. -V erify operation of heating. - Inspect coil. Inspection visit - Carry out leak test. Inspect contacts and tighten terminals. Record operating pressures, amperages and voltage. Check condition of evaporator & condenser coils. Check operation of machines/compare conditions of operation against original commissioning data. - Carry out flue gas analysis ( Gas Heating ). - Complete log sheet and review with the operator. 46 RT-SVX056D-GB Additional services Oil analysis Trane Oil Analysis is a predictive tool used to detect minor issues before they become major problems. It also reduces failure detection time and allows planning for appropriate maintenance. Oil changes can be reduced by half resulting in lower operating costs and a lower impact on the environment. Refrigerant analysis This Service includes a thorough analysis for contamination and solution upgrade. It is recommended that this analysis be performed every six months. Trane Select Agreements Trane Select Agreements are programs tailored to your needs, your business and your application. They offer four different levels of coverage. From preventive maintenance plans to fully comprehensive solutions, you have the option of selecting the coverage that best suits your requirements. 5 years motor-compressor warranty This Service will provide a 5 years part and labor warranty for the motor compressor only. This Service is only available for units covered by a 5 years Maintenance Contract. Energy enhancement With Trane Building Advantage you can now explore cost effective ways to optimize the energy efficiency of your existing system and generate immediate savings. Energy management solutions are not only for new systems or buildings. Trane Building Advantage offers solutions designed to unlock energy savings in your existing system. EC fans NOTE: If the built-in device is switched off for a long time in a dry environment it is important to do this run one hour at full speed at least every four month. If the built-in appliance is shut down for a long time period in a humid environment (e.g. outdoors), it is important to run it for at least three hours at full speed every month, so that the bearings are in movement and that the condensate having possibly entered the interior can evaporate. RT-SVX056D-GB 47 Trane - by Trane Technologies (NYSE: TT), a global climate innovator - creates comfortable, energy efficient indoor environments for commercial and residential applications. For more information, please visit trane.com or tranetechnologies.com. Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. RT-SVX056D-GB November 2020 Supersedes RT-SVX056C-GB (December 2017) Confidential and proprietary Trane information © 2020 Trane ">
/
Download
Apenas um lembrete amigável. Você pode visualizar o documento aqui mesmo. Mas o mais importante, nossa IA já o leu. Ele pode explicar coisas complexas em termos simples, responder às suas perguntas em qualquer idioma e ajudá-lo a navegar rapidamente, mesmo nos documentos mais longos ou complicados.
Anúncio