Parker Airtek Smart Cycle Plus SCP1200 User Manual
PDF
Document
Advertisement
Advertisement
Airtek Smart Cycle Plus Models SCP1200 to SCP3000 User Guide - PUB042209 REV. B SCP 1200 - 3000 USER GUIDE Contents 1 2. 3. 4. Getting Started 1.1 Environmental & Location Considerations Dryer Installation 2.1 2.2 2.3 4 5 6 7 DP5550 Displays 9 Start-Up Procedure 4.1 4.2 3 4 Plumbing the Air Lines Electrical Connections Electrical Hook-up Controls 3.1 3 13 Smart Cycle Plus 1200 – 3000 When Operating Dryer 13 14 5. Routine Maintenance 15 6. Diagnostic Codes & Troubleshooting 16 7. Optional Control Center 18 Maintenance Charts 40 8. 8.1 8.2 Maintenance Procedures Routine Maintenance 40 41 10. Spare Parts List 79 11. Warranty and Product Registration 80 2 - REV. B SCP 1200 - 3000 USER GUIDE 1 Getting Started Before unpacking/uncrating your new dryer, inspect the carton/crate for damage. Note any damage on the freight bill. File notice of concealed damage if: (a) there are any dents in the cabinets (b) there is any sign of oil on the skid or floor (c) the refrigerant gauge shows NO pressure (Upper right side – look for hole in packing) File these claims with the carrier immediately! Otherwise, proceed with unpacking/uncrating the unit. 1.1 Environmental & Location Considerations Following these guidelines will help insure that your new dryer will provide safe and reliable service. • Unless supplied for special conditions, all SCP dryers must be located indoors in an area with an ambient temperature between 41 - 100ºF (5-37.7ºC) and free from explosive and corrosive fumes. Three (3) feet (92cm) of space must be allowed between all open grills, walls, or other objects. If the dryer is installed in a confined area, an exhaust system must be provided to eliminate re-circulation of hot atmospheric air. • High ambient temperatures affect the outlet dew point of the dryer. For every 10º of ambient temperature over 100ºF (37.7ºC) a decrease of 10% of dryer performance is encountered with air cooled dryers. The unit must not operate in an ambient of over 115ºF (46ºC). If ambient temperature conditions are over 100ºF (37.7º), water cooled dryers are recommended. • Unit must be installed indoors. 3 - REV. B SCP 1200 - 3000 USER GUIDE 2. Dryer Installation • NEVER work on unit under pressure • NEVER work on unit when power is connected • DO NOT over pressurize unit. • DO NOT pass air through the unit until it has been stabilized (operating about 15-20 minutes) 2.1 Plumbing the Air Lines The dryers are shipped ready to run. All connections are made to the outside of the cabinet • Air piping must be supported independently of the dryer. • Direction of the air flow must be observed for proper installation. • Use unions or flange joints on inlet and outlet pipe connections. • If vibration is present, flexible metal hoses must be installed to prevent the vibration from being transmitted to the dryer. • Install a bypass line and gate valves to permit isolation of the dryer from the air system. This is done to provide easy service and/or removal of the dryer without interruption of air to the system. USE TWO (2) WRENCEHS WHEN CONNECTING DRYER TO PIPING. THIS WILL PREVENT DAMAGE TO INTERNAL AIR LINES. 4 - REV. B SCP 1200 - 3000 USER GUIDE 2.2 Electrical Connections To be performed by a qualified person only. Risk of serious injury or death. Before connecting electrical power to the dryer check for correct voltage and phase at the connection box. All units must be externally grounded to protect against severe electrical shock. Service Switch (On Models SMART CYCLE PLUS 1200 to 3000) 5 - REV. B SCP 1200 - 3000 USER GUIDE 2.3 Electrical Hook-up 1. 2. 3. 4. 5. 6. 7. 8. Voltage Phase Wire Colors 115V Single Black, White, Green 230V Single Black, Red, Green 230V 3 Phase 3 Black, 1 Green 460V 3 Phase 3 Black, 1 Green 575V 3 Phase 3 Black, 1 Green Remove side cover and locate electrical box. Remove electric box cover from inside unit. Locate the wires. Locate hole on side of box, place and tighten connector, run wires through connector. Using wire connectors, connect Black to Hot wire, White to Neutral and Green to Ground wire. Refer to table above for voltage and wire colors. Make sure no bare wire is exposed; replace box cover and screw closed. Turn Service Switch “ON”. Replace side covers. Wire the dryer separately from the air compressor. The dryer must not cycle with the air compressor. Phase rotation is important if the dryer has a 3 phase condenser (SCP3000). Fans must pull air through condenser coil. Crankcase heaters are pre-wired from the factory to the line side of the compressor contactor. When power is applied to the dryer, the heater will energize. Heater must be energized for 12 hours prior to start–up and after prolonged shut down. The power must be left on at all times except when servicing. 6 - REV. B SCP 1200 - 3000 USER GUIDE 3. Controls (1) – RUN SELECT KEY: (MODE SELECTOR) Push Key to toggle through the four modes of operation (‘AUTO’ Run Mode, ‘LOAD/ UNLOAD’ Mode, ‘CYCLING’ Mode, and ‘OFF’). The Display ‘main screen’ will indicate all modes of operation along with the current Dew Point measurement. (2) – ALARM KEY: (RESET ALARMS) When the ALARM Key red ‘LED’ is flashing, the system has experienced an alarm event. The Display will indicate all alarms when they occur. Pushing the ALARM Key will attempt to clear the fault. Note with some alarms, the system will need to be restarted. (3) – DRAIN KEY: (OPERATE DRAIN) When the ‘DRAIN’ Key is pressed, the drain solenoids will operate for the programmed time duration. (see Settings, Drains). The green LED will illuminate indicating the drains are open. (4) – LOAD KEY: (VIEW LOAD %) Pushing the ‘LOAD’ Key will toggle the Display between indicating ‘Mode & Dewpoint’ (standard), and, ‘Percent of Load’ (optionally) that the dryer is experiencing. The green LED will illuminate indicating the display option is active. (5) – READ KEY: (MEASUREMENT READINGS) The ‘READ’ Key will scroll through each system measurement. (6) – SETTINGS KEY: (PROCESS VALUES) The ‘SETTINGS’ Key will scroll through each user setting (process value). The amber LED will illuminate indicating the display is active. 7 - REV. B SCP 1200 - 3000 USER GUIDE (7) – YES / UP KEY: (YES & UP) When the ‘YES / UP’ Key is pressed, the controller will either increment up or toggle depending on which user setting is selected in the ‘SETTINGS menu. Note the SETTINGS Key amber LED will now flash. To save the ‘new’ process value setting, press the SETTINGS Key again – a message ‘ARE YOU SURE?’ will display (answer either YES or NO, the LED will stop flashing. (8) – NO / DOWN KEY: (NO & DOWN) When the ‘NO / DOWN’ Key is pressed, the controller will either decrement up or toggle depending on which user setting is selected in the ‘SETTINGS menu. Note the SETTINGS Key amber LED will now flash. To save the ‘new’ process value setting, press the SETTINGS Key again – a message ‘ARE YOU SURE?’ will display (answer either YES or NO, the LED will stop flashing. (9) – MULTI COLORS INDICATOR: These LED’s will illuminate in RED, AMBER and GREEN. They represent a ‘visual’ indication as to dryer loading. If all the LED’s are RED, this is the worst possible state (a combination of very bad dew point and or overloaded. The other side of the spectrum would be only one GREEN LED illuminated; indicating less then (<10%) ten percent capacity is being utilized and all is OK. (10) – MAINTENANCE MONITOR: The controller will remind the user to perform maintenance on the dryer every six month. The Display will indicate (and the ALARM LED will flash), the statement “CHANGE FILTER.” IMPORTANT – The user should change the coalescing filter on a regular basis. Also do all other recommended maintenance (see maintenance section of the Operating Manual) at this time. To reset the ‘Maintenance Monitor’ at the completion of the maintenance procedures, push the ALARM Key and when the “HAS FILTER BEEN CHANGED? (YES / NO)” message is in the Display, press the ‘YES’ Key. Pressing the YES Key will reset the Change Filter timing for six months. Selecting the ‘NO’ key will exit the menu and the message will repair again in 8 hours. OTHER FEATURES: On ‘power-up’ the Display will indicate the system configuration (System Operating Code #, CFM Range and Firmware Revision) for three seconds. 8 - REV. B SCP 1200 - 3000 USER GUIDE (11) Air Inlet & Outlet PSI Gauges. Indicates that unit is pressurized. Unit MUST be depressurized and bypassed before any service work is done on air system. Excessive pressure drop (more than 5 PSIG) across dryer indicates water may be freezing in the evaporator. 3.1 DP5550 Displays Power On Screen – Displayed for 3 seconds after power-on or reset [4] 1500-3000 CFM 1.0.4.9x/Dec 1 2009 Model and Size Firmware Rev/Date Main Display - System OFF SYSTEM OFF Press Run Select Main Display - System Running, No Alarms Press the RUN SELECT key to cycle thru the operating modes AUTO MODE (L) Operating Mode DEW POINT:36°FOperating Dew Point Operating Modes “SYSTEM OFF” “AUTO MODE (L)” (L) = load/Unload Mode, (C) = Cycling Mode “LOAD/UNLOAD MODE” “CYCLING MODE” Main Display - System Running, with Warning Alarms HIGH INLET TEMP Alarm Description(s) Operating Dew Point DEW POINT:36°F Warning Alarms “HIGH DEW POINT” “DRAIN FAULT” “HIGH CONDENSER TEMP.” “HIGH INLET TEMP” “HIGH DIFF PRESSURE” “BAD SENSOR WARNING” “CHANGE FILTER” 9 - REV. B SCP 1200 - 3000 USER GUIDE Note: if more than one alarm condition exists, then the top line of the display will automatically cycle thru all active alarms. Main Display - System Shutdown Due To Critical Alarm HIGH DISCHARGE PRES. Alarm Description Shutdown status Alarm Shutdown Critical Alarms “DRYER OVERLOAD” “BAD SENSOR SHUTDOWN” “LOW SUCTION PRESSURE” “HIGH DISCHARGE PRES.” “HIGH SUPERHEAT” “EVAPORATOR FROZEN” “EMERGENCY STOP” “BAD PUMPDOWN” “SYSTEM FAULT” Press the ALARM key to reset all alarms AUTO MODE (L) Alarm Shutdown Press the RUN SELECT key to restart the dryer after an alarm Note: if more than one alarm condition exists, then the top line of the display will automatically cycle thru all active alarms. Read System Parameters Press the READ key to cycle thru the system parameter values Dew point Parameter Description 36°F Parameter Value Dew Point Temp. Superheat Temp. Suction Temperature Suction Pressure Discharge Pressure 0 thru 200°F 0 thru 100°F 0 thru 200°F 0 thru 600 psi 0 thru 600 psi 10 - REV. B SCP 1200 - 3000 USER GUIDE Inlet Temperature Condenser Temperature 0 thru 200°F 0 thru 200°F Note: The parameter value will display “FAULT!” if the sensor input is invalid Settings Menu - User Settings Press the SETTINGS key to cycle thru the user settings TARGET DEW POINT? 36°F Setting Description User Settings DefaultSettings TARGET DEW POINT? 38 oF 36 thru 50 °F DRAIN DURATION? 2 secs 1 thru 30 seconds DRAIN CYCLE? 60 mins 0 thru 60 minutes MAX CONDENSER TEMP? 100°F 0 thru 125°F MAX INLET TEMP? 101°F 0 thru 125°F TEMPERATURE UNITS? °F °F, °C PRESSURE UNITS? psi psi, kPa, bars NETWORK ADDRESS? 1 1 thru 247 Changing the User Settings TARGET DEW POINT? Setting Description 36°F Use the UP and DOWN keys to change the setting Press the SETTINGS key when finished TARGET DEW POINT? Select YES or NO to confirm YES selected, store setting NO selected, restore previous setting ARE YOU SURE? New Setting Saved Setting NOT Saved! 11 - REV. B SCP 1200 - 3000 USER GUIDE Load Display Press the LOAD key to display the dryer load percentage Dryer Load 67% Clearing the Maintenance Timer Press the ALARM RESET key to reset the maintenance timer and alarm HAS FILTER BEEN REPLACED? (YES/NO) Press YES to reset the timer to 6 months (after maintenance has been performed) Press NO to reset the timer to 8 hours (until maintenance has been performed) 12 - REV. B SCP 1200 - 3000 USER GUIDE 4. Start-Up Procedure There should be NO air flow through the dryer before or during start-up. It is recommened that the dryer be installed with bypass piping to better service the unit. 4.1 Smart Cycle Plus 1200 – 3000 1. After electrical connection (Refer to Section 3), apply power. 2. After power has been applied the control panel should say “OFF” and the crankcase heater will now start heating. THE CRANKCASE HEATER MUST BE SWITCHED ON 12 HOURS BEFORE STARTING THE DRYER. Failure to comply with this rule may cause serious damage to the compressor. 3. Remove side panel from unit. 4. Some units are shipped with the refrigeration service valve tagged. These tagged service valves must not be opened until the dryer is ready to be started and the main power is permanently applied. Only tagged service valves must be opened. 5. Locate tagged service valves and remove end cap from valve stem. (Fig. 3 below) 13 - REV. B SCP 1200 - 3000 USER GUIDE 6. Using a refrigeration service or small crescent wrench, turn the valve stem counterclockwise until it stops. Occasionally, it may be necessary to re-tighten the packing nut (turn clockwise) if a leak is noticed. The valve will now be fully opened. (Fig. 3) 7. Replace cap. 8. Once the crankcase heater has been pre-heated, pressure the RUN SELECT button on the control panel to start the dryer. 9. If the storage conditions were adverse (for example very cooled) the refrigeration compressor may make a loud metallic hammering noise. If this happens, turn the dryer off at the panel and wait 60 seconds. Then turn the dryer back on. Repeat this procedure until the refrigeration compressor runs smoothly. The dewpoint should start to drop towards the set point. Do not pass air through the dryer until it is stabilized. (Unit cycles 2 – 3 times) 10. With the dryer turned on from the control panel, and is stabilized, you can now introduce compressed air to the dryer. 11. Check the automatic drain for proper operation. Drain should open at regular intervals based on the drain control settings. Clean Y-Strainer on drains after the first 4 hours of operation. (See Section 5.0, Fig. 4) 12. 4.2 Restart dryer using this procedure after maintenance, power outage or prolonged periods of shutdown. When Operating Dryer 1. 2. 3. 4. 5. 6. 7. 8. Turn dryer On and Off at control panel only. Keep power to unit at all times except when servicing. Start dryer prior to allowing air flow through unit. Clean condenser when necessary. Maintain ambient temperature between 41-100ºF (5-37.7ºC) Keep inlet temperature under 101ºF (38ºC) Check and clean Y-strainer regularly. NEVER allow dryer to cycle ON/OFF with air compressor. 14 - REV. B SCP 1200 - 3000 USER GUIDE 5. Routine Maintenance The air cooled condenser must be kept clean. Inspect on a regular basis for dirt or debris that might accumulate. Remove any debris immediately. It is recommended that the drain and solenoid be checked weekly for proper functioning. The Y-strainer should be checked and screen cleaned monthly. (Fig. 4) It is not advisable to tamper with the other adjustments unless you are familiar with refrigeration. The controls interact with each other and, although the effect of an adjustment may not be immediately obvious, it will affect the dryer’s performance. CHARGE LIQUID REFRIGERANT ONLY, DO NOT CHARGE WITH VAPOR! • • • See tag for correct refrigerant charge. Unit needs to be pulled into vacuum 500 micron (minimum) The full charge might not be accepted. If this occurs, the unit can be started and then the remainder of the charge should be slowly metered into the suction side (Suction side is always the inlet to compressor side). 15 - REV. B SCP 1200 - 3000 USER GUIDE 6. Diagnostic Codes & Troubleshooting CODE CONDITION TIMEOUT SHUTDOWN HIGH DEW POINT 11 Actual dew-point is 15ºF above the target setting 2 seconds No Auto DRYER OVERLOAD 12 Dew Point > Set Point +40ºF 10 minutes YES MANUAL BAD SENSOR SHUTDOWN 13 Dew Point, Suction Temp, Suction Pressure, or Discharge Pressure is reading out of range 2 seconds YES MANUAL LOW PRESSURE 14 Suction PSI < Set point during compressor on 5 seconds YES MANUAL HIGH PRESSURE 15 Discharge Pressure > High Setting, or Switch is open while compressor is on 1 Seconds YES MANUAL HIGH SUPERHEAT! (Semi-Hermetic) 16 Compressor is running. Superheat Calculation is >40ºF and Suction temperature >75ºF 40 minutes no Auto HIGH SUPERHEAT! (Hermetic) 16 Compressor is running. Superheat Calculation is >40ºF and Suction temperature >75ºF 40 minutes YES MANUAL DRAIN FAULT 17 Drain switch is closed for too long See Note 1 No Auto FROZEN EVAP! ALARM RESET 18 Dew-Point <= 20ºF 10 minutes YES MANUAL HIGH CONDENSER TEMP 21 Ambient/Water temperature is higher than setting 60 seconds No Auto HIGH INLET TEMP 22 Inlet temperature is higher than setting 60 seconds No Auto HIGH DIFFERENTIAL PRESSURE SWITCH 23 Input from PSID switch is closed 2 seconds No Auto EMERGENCY STOP 24 E-Stop switch is opened or internal fuse is blown 2 seconds YES MANUAL BAD PUMP DOWN 25 Pressure switch remains open for 1 minute after shutdown, or cycles more than 8 times per hour 1 hour (see description) YES MANUAL BAD SENSOR WARNING 26 Inlet, or Condener temperature is reading out of range 2 seconds No Auto NON-RECOVERABLE SYSTEM FAULT 27 Dryer is not configured or configuration has been corrupted 1 Seconds YES MANUAL CHANGE FILTER 28 Timer has timed out 6 months or 8 hours No MANUAL Note 1 - Timeout is Drain Duration setting +10 seconds 16 - REV. B SCP 1200 - 3000 USER GUIDE ALARM FAULTCODE CAUSE REMEDY 11 1) Thermal load is too high. 2) Condenser is dirty. 1) Reduce compressed air quantity and/or inlet temperature. 2) Clean condenser. 12 1) Thermal load is too high. 2) Unloader valve not closing. (Temperature on the copper lines of each side of the valve will be equal) 3) Compressor will not start, no hum. 4) Compressor will not start, hums but trips overload. 1) Reduce compressed air quantity and/or inlet temperature. 2) Replace valve internals (Repair Kit). 3) Check for: Service switch in OFF position, loose or improper wiring, overload tripped, bad starter. 4) Check for: Loose or improper wiring or voltage, overload tripped, bad starter or compressor failure. 13 1) Sensor connection is loose or disconnected. 2) Sensor is defective. 1) Identify which sensor (scroll thru control panel readings to find faulty sensor) & tighten connections. 2) Identify which sensor (scroll thru control panel readings to find faulty sensor) & replace. 14 1) Refrigerant leak. 2) Low pressure switch defective. 3) Suction line solenoid not opening. 4) Liquid line solenoid not opening. 1) Locate leak. Repair and recharge. 2) Replace. 3) Replace valve internals (Repair Kit) or coil. 4) Replace valve internals (Repair Kit) or coil. HIGH PRESSURE 15 1) Condenser dirty / blocked. 2) Fan pressure switch defective. 3) Fan motor defective. 4) Ambient temperature too high. 5) High pressure switch defective. 6) Low water flow. 7) Water valve defective. 8) Liquid line valve or coil defective. 1) Clean condenser. 2) Replace. 3) Replace motor. 4) Improve room ventilation. 5) Replace. 6) Fix water supply. 7) Replace. 8) Replace valve internals (Repair Kit) or coil. HIGH SUPERHEAT 16 1) Refrigerant leak. 2) Defective superheat probe. 3) Poor contact of superheat probe. 4) Faulty expansion valve. 1) Locate leak. Repair and recharge. 2) Replace. 3) Tighten probe to refrigerant line. 4) Replace. DRAIN FAULT 17 1) Valve strainer clogged. 2) Drain valve clogged. 3) Solenoid defective. 4) Level sensor defective. 1) Clean. 2) Dis-assemble and clean. 3) Replace. 4) Replace. FROZEN EVAP! 18 1) Unloader valve not opening. Defective valve or coil. 1) Replace valve internals (Repair Kit) or coil. HIGH CONDENSER TEMP 21 1) Ambient too high. 1) Improve room ventilation. HIGH INLET TEMP 22 1) Inlet air temperature too high. 1) Clean air compressor aftercooler and or improve room ventilation. HIGH DIFFERENTIAL PSI 23 1) Coalescing filter is dirty. 2) Excessive compressed air flow. 1) Change filter (see serial sticker for part #). 2) Reduce flow. EMERGENCY STOP 24 1) E-stop switch is opened. 2) Internal fuse blown. 3) E-stop jumper is disconnected. 1) Close switch. 2) Replace. 3) Replace. BAD PUMP DOWN 25 1) Suction valve not fully closing. 2) Unloader valve stuck open. 3) Compressor is defective. 1) Replace valve internals (Repair Kit). 2) Replace valve internals (Repair Kit). 3) Replace. BAD SENSOR WARNING 26 1) Sensor connection is loose or disconnected. 2) A sensor is defective. 1) Check/tighten connections. 2) Identify which sensor & replace. NON-RECOVERABLE SYSTEM FAULT 27 1) Not programmed properly. 1) Consult factory for settings and programming instructions. CHANGE FILTER 28 1) Filter is dirty. 1) Check and replace if necessary (see serial sticker for filter part #). HIGH DEW POINT DRYER OVERLOAD BAD SENSOR SHUTDOWN (Dewpoint, Suction Temp, Discharge psi or Suction psi) LOW PRESSURE 17 - REV. B SCP 1200 - 3000 USER GUIDE 7. Optional Control Center 18 - REV. B SCP 1200 - 3000 USER GUIDE PREFACE: This document is intended to make familiar, the Control Center functionality. The “manual”, can serve as a handy guide to quickly move through the operations of the dryer it is controlling. It is not intended to replace the more comprehensive, specific “dryer manual” that will show all other aspects of operation and safety. It is IMPORTANT that both manuals be referenced for complete dryer understanding. MENU TREE a. STARTUP NULL SCREEN--------------------------------------------------------------------[ 4 ] • PRE-SETUP • STARTUP • CHANGE MODES b. MAIN SCREEN------------------------------------------------------------------------------[ 5 ] • DISPLAY ORIENTATION • TYPICAL SCREEN DISPLAYS c. EVENTS-------------------------------------------------------------------------------------[ 6 ] • EMERGENCY STOP • STANDBY • DEWPOINT OPTION (not installed) • ACTIVE ALARMS • DEWPOINT ALARMS • NO FLOW d. REVIEW ALARM LOG (“J” Series Menus)--------------------------------------------------[ 6 ] e. DISPLAY SENSOR VALUES (“K” Series Menus)-------------------------------------------[ 8 ] • FLOW METER (4-20Ma/1 to 5 volt INPUT) MAIN MENU 1 DEWPOINT SETTINGS (“D” Series Menus)--------------------------------------------------[ 9 ] • DEWPOINT SETPOINT 2. SETUP MENU (“E” Series Menus)----------------------------------------------------------[ 10 ] • COMPANY INFORMATION-----------------------------------------------------------------[ 10 ] PHONE & www MESSAGE • PRODUCT INFORMATION-----------------------------------------------------------------[ 10 ] TYPE OF DRYER & SN# FACTORY DEFAULTS GO TO “NULL” STATE CALIBRATION MENU (“H” Series Menus) INLET PRSSURES REHEATER PRESSURE OUTLET PRESSURE DISCHARGE PRESSURE SUCTION PRESSURE ELEMENT DP SETTINGS FLOW RANGE SETTINGS • DRAINS SETUP MENU (“I” Series Menus)----------------------------------------------[ 12 ] #1 DEMAND or TIMED OPERATIONS 19 - REV. B SCP 1200 - 3000 USER GUIDE #1 INTERVAL (Timed) #1 DURATION #1 AUTOTEST #2 DEMAND or TIMED OPERATIONS #2 INTERVAL (Timed) #2 DURATION #2 AUTOTEST • COMMUNICATON MENU (“F” & “G” Series Menus)--------------------------------------[ 12 ] ADJUST CLOCK STAR WATCH – Host to Control: YES MODEM SETUP MODEM ENABLE MODEM TEST MODEM RESET (Reprogram) VIEW MODEM SETTINGS 3. SENSOR SETTINGS (“C” Series Menus)---------------------------------------------------[ 14 ] • P1: LOW INLET PRESSURE • P1: HIGH INLET PRESSURE • P2: REHEATER PRESSURE • P3: OUTLET PRESSURE • P4: DISCHARGE PRESSURE • P5: SUCTION PRESSURE • P6: SEPARATOR DP • FLOW 4. TEMPERATURE SETTINGS (“B” Series Menus)--------------------------------------------[ 15 ] • T1: DRYER INLET SETPOINT • T2: PRECOOLER SEPOINT • T3: DRYER OUTLET SETPOINT • T4: REFRIGERANT SETPOINT • T5: SUCTION SETPOINT • T6: AMBIENT/H2O SETPOINT 5. VIEW ALARMS (“A” Series Menus)--------------------------------------------------------[ 15 ] • HIGH DEWPOINT • LOW FLOW • (E1/E2) DEWPOINT PROBE FAULT (OPEN OR SHORT) • MOTOR OVERLOAD • (E3) SUPERHEAT OUT OF RANGE • (E4) LOW DEWPOINT • (E5) DRYER OVERLOAD • (E6) LOW FREON OR OIL PRESSURE • (E7) HIGH FREON PRESSURE • (W1) LOW AIR-IN PSI • (W2) HIGH AIR-IN PSI • (W4) HIGH INLET AIR TEMP • (W5) HIGH AMBIENT/H2O TEMP • (W6) DRAIN FAULT • MODEM FAULT 20 - REV. B SCP 1200 - 3000 USER GUIDE 1. Up Arrow 2. Down Arrow 3. Set 4. Reset Alarm 5. Load/Un-Load 6. Thermal Bank 7. Auto Run 8. Drain Test 9. Display Values 10. Review Alarm Log Scroll Menu Up or Increment Value Scroll Menu Down or Decrement Value Enter Menu Selection, Enter Program Mode or Save to Memory Back-up Menu Level or Clear ‘Resetable’ Alarm Load/Un-Load Mode Selector Thermal Bank Mode Selector Auto Mode Selector – Automatically Sequences to Demand (#5 or #6) Operates Both Drain System for Programmed Duration Enters Sensor Menus – Indicates Current Values (Series ‘K’ Screens) Enters Historical Log of Alarm Event (Series ‘J’ Screens) 21 - REV. B SCP 1200 - 3000 USER GUIDE a. STARTUP NULL SCREEN-----------------------------------------------------------------Upon initialization, the display shows the “type” of dryer the Control Center is configured to control. An example: Company REFRIG DRYER (R404A) S/N B00001 V2.12IR4 This is a fixed configuration. Once assigned to a dryer: the Control Center will never be changed to any of the other configurations. Note that the Control Center Serial Number, Refrigerant Type and Firmware Version are also displayed on the null, initialization screen. PRE-SETUP Prior to starting up the dryer, the DISPLAY VALUES button may be selected to view groupings of sensors (use the up/down arrows to scroll through the list) Depress the Display Values button a second time, or the Alarm RESET button to return to the Main Screen. Also, all of the other screens and menus can be viewed by using the up/down arrows. Simply position any particular menu choice into view and advance a menu level by depressing the SET button. Returning to the Main Screen can be achieved at any time by depressing the Alarm RESET button. These screens may be viewed at any time, and at any state of operation. The Main Screen of the Fan Inactive System prior to start-up (run mode) is the NULL Screen above, when returning to the Main Screen from viewing any of the above Pre-Startup procedures. STARTUP TO START the dryer, select any of three main operating modes by depressing their button. • AUTO Mode (normal operations) dryer will automatically sequence between the Load/Un-Load and Thermal Bank modes as required by demand. • LOAD/UN-LOAD Mode (cycling operation), or • THERMAL BANK Mode (cycling operation including compressor including OFF). CHANGING MODES The dryer can change modes of operation by simply depressing the any desired mode button. To return the dryer to an INACTIVE (SYSTEM OFF-STANDBY) state, depress, the “current mode” button as is indicated by the Mode Pilot indicator (LED). 22 - REV. B SCP 1200 - 3000 USER GUIDE b. MAIN SCREEN--------------------------------------------------------------DISPLAY ORIENTATION There are several informational indications displayed on the Main Screen. They are displayed on the four lines of the LCD. 1. The first line is the “message” line. If all is normal, this line will indicate ALL SYSTEMS OK, or else it will indicate an alarm; for example, HIGH DEWPOINT. If more than one alarm is active, this message line will “scroll” between any and all messages. 2. The second line is the “mode” line. This line will indicate the dryers operations: • SYSTEM INACTIVE (NULL), • EMERGENCY STOP, • AUTO RUN MODE • LOAD/UN-LOAD MODE, • THERMAL BANK MODE, • SYSTEM OFF, and • ALARM SHUT DOWN 3. 4. The third line is the “process” line. INITIALIZING, POWERSAVE ACTIVE or may be blank for all other normal operations. The forth line is dedicated to the current DEWPOINT value. TYPICAL SCREEN DISPLAYS----------------------------------------------------------------------------Below is a sampling of typical display screens; showing some of the possible system operations. ALL SYSTEMS OK AUTO RUN MODE POWERSAVE ACTIVE DEWPOINT 34ºF (1ºC) MOTOR OVERLOAD ALARM SHUTDOWN DEWPOINT 39ºF (4ºC) ALL SYSTEMS OK SYSTEMS OFF DEWPOINT 65ºF (18ºC) COMPRESSOR WILL CONTINUE TO RUN UNTIL RUMPDOWN IS COMPLETE STARWATCH ACTIVE AUTO RUN MODE DEWPOINT 33ºF (0ºC) 23 - REV. B SCP 1200 - 3000 USER GUIDE c. EVENT--------------------------------------------------------------------------------------EMERGENY STOP At any time the dryer’s E-STOP pushbutton is depressed, the dryer will immediately “stop” operations (all output will be de-energized except for COMMON ALARM dry output relay and MODEN relay). To restart the dryer, the flashing mode (AUTO RUN, LOAD/UNLOAD or THERMAL BANK) selector must be re-selected. Note – the E-STOP pushbutton must be rotated and pulled “out” to its normal position before the re-start can be invoked. ACTIVE ALARMS EMERGENCY STOP! DEWPOINT 35ºF (2ºC) ALARM SHUT DOWN When a “shut-down” alarm occurs, the dryer will “stop operating and will require a Manual Reset (see VIEW ALARMS section). Once the alarm has been reset and if the alarm condition has been cleared, the system may be re-started. The current mode LED will be flashing. When the mode selector button is depressed, the system will restart and LED will stop flashing and remain illuminated. LOW FREON/OIL PSI ALARM SHUT DOWN DEWPOINT 35ºF (2ºC) IMPORTANT All screens from section (d.) forward to the end of this manual are indicated with an alphanumeric indication in the upper left corner of the display as a screen ID. The CONTR d. REVIEW ALARM LOG (“J” Series Menus)------------------------------------------------------------When the Review Alarm Log pushbutton is depressed, the “J” series screens will be displayed. Each “J” screen shows the status of a possible alarm. The UP/DOWN arrow will allow scrolling through 16 different alarm conditions. The number appearing next the “DAYS SINCE LAST”, indicated the last time that the alarms condition has occurred. A zero (0) indicates the current date. For example, 365 would indicate exactly one year since the occurrence of any particular alarm. If “---“ is indicated, that means the selected alarm has never happened. All screens from section (d.) forward to the end of this manual are indicated with an alphanumeric indication in the upper left corner of the display as a screen ID. The CONTROL CENTER will display these ID’s as any given screen is selected within the menu tree. Please make note of any particular screen ID when communicating with a support representatives, which may be in question. When an alarm is tripped, the “COMMON ALARM RELAY” (K16) will energize if the “ALARM OUT” is ENABLED. 24 - REV. B SCP 1200 - 3000 USER GUIDE There is a form “C” dry contact available for the user on K16 (see schematic). To “DISABLE” the ALARM OUT from energizing the Common Alarm relay, use the SET and UP/DOWN arrow buttons to disable any given alarm. All alarms are factory default to “ENABLED”. The used can program anyone, any combination, or all alarms to activate the Common Alarm relay. J1 ALARM LOG HIGH DEWPOINT DAYS SINCE LAST: 1 ALARM OUT: YES J2 ALARM LOG LOW FLOW DAYS SINCE LAST: 25 ALARM OUT: YES J3 ALARM LOG DP PROBE DEFAULT DAYS SINCE LAST: 365 ALARM OUT: YES J4 ALARM LOG MOTOR OVERLOAD DAYS SINCE LAST: --ALARM OUT: YES J5 ALARM LOG E3: HI SUPERHEAT DAYS SINCE LAST: --ALARM OUT: YES J6 ALARM LOG E4: DRYER OVERLOAD DAYS SINCE LAST: --ALARM OUT: YES J7 ALARM LOG E5: LOW PRESSURE DAYS SINCE LAST: --ALARM OUT: YES LOW REFRIGERANT/OIL PRESSURE NOTE IF MULTIPLE COMPRESSORS – SEE ACTIVE ALARMS HIGH REFRIGERANT PRESSURE 25 - REV. B J8 ALARM LOG E6: LOW PRESSURE DAYS SINCE LAST: 0 ALARM OUT: YES J9 ALARM LOG E7: HIGH PRESSURE DAYS SINCE LAST: --ALARM OUT: YES SCP 1200 - 3000 USER GUIDE J11 ALARM LOG W2: HIGH AIR-IN PSI DAYS SINCE LAST: --ALARM OUT: ENABLED J12 ALARM LOG W3: CHANGE FILTER DAYS SINCE LAST: --ALARM OUT: YES COALESCER ELEMENT DIFFERENTIAL PRESSURE J13 ALARM LOG W4: HIGH AIR-IN ºF DAYS SINCE LAST: --ALARM OUT: YES J14 ALARM LOG W5: HIGH AMBIENT/H2O DAYS SINCE LAST: --ALARM OUT: YES J15 ALARM LOG E9: DRAIN FAULT DAYS SINCE LAST: --ALARM OUT: YES J16 ALARM LOG MODEM FAULT DAYS SINCE LAST: 1 ALARM OUT: YES E. DISPLAY SENSOR VALUES (“K” Series Meus)------------------------------------------------The DISPLAY VALUE pushbutton is a quick way to view groupings of sensor values. The UP/DOWN arrows will scroll through the 7 possible groups of the “K” series screen. K1 Superheat 12ºF T4: Refrig 130ºF P4: Discharge 100 psi P5: Suction 96 psi R TYPE: R404A K2 Superheat T5: Suction P5: Suction 26 - REV. B 12ºF 100ºF 100 psi SCP 1200 - 3000 USER GUIDE K3 Dewpoint 33ºF T1: Inlet P1: Inlet T6: Ambient/H2O of 100ºF 100 psi 54ºF K4 P1: Inlet P1: Outlet P6: Filter Element NOTE IF NOT “OK” = CHANGE FILTER WILL BE INDICATED 100 psi 98 psi OK K5 T1: Inlet T3: Outlet 100ºF 90ºF K6 T6: Ambient/H2O of 67ºF P4: Discharge 250 psi -Flow 10000 scfm K7 T1: Inlet T3: Outlet PI: Inlet P3: Outlet 100ºF 90ºF 100 psi 98 psi K8 Auxiliary #1 Auxiliary #2 Flow K9 Power: Current: Speed: Frequency: CUSTOM ENGINEERED UNITS NOTE Auto-Sequence “Time” can be selected between 1 & 72 hours. (See Compressor Menu’s R1 – R5 to ENABLE or DISABLE by pressing the SET. K10 COMPRESSORS Timer: C1: STNDBY C3: ONLINE DISABLED 75 DISABLED 10.4 Kw 12.4 A 13000 RPM 45 Hz 23:59 h:m C2: ONLINE C4: DISABL FLOW METER: All Control Center’s come standard with flow sensor input capabilities. Simply “hook-up” a 4-20mA loop, or a 1 to 5 volt signal to the appropriate flow input (see schematic/wiring diagram)and activate the FLOW ENABLE in the SETUP screens. The loop may be powered by the Control Center or powered externally. The FLOW measurement is displayed in the “K6” screen only if enabled. Refer to schematic for configuring panel to “current/voltage” only if enabled. Call support for details or questions. 27 - REV. B SCP 1200 - 3000 USER GUIDE 1. DEW POINT MENU----------------------------------------------------------------------------------DEWPOINT MENU Press SET to Select DEWPOINT – The dryer will attempt to deliver a dew point relative to the DEWPOINT SET POINT value. The range for this setting can be selected between 34ºF (1ºC) to 50ºF (10ºC). When the dew point indicated is at the set point value or less, the panel LCD display will give a message: POWERSAVE ACTIVE D1 DEWPOINT Value: Set Point: 36ºF 34ºF 2. SETUP MENU-------------------------------------------------------------------------------------------Screen series: “E”, “F”, “G”, “R” and “I” are within the set-up selections. SETUP MENU Press SET to Select E2 PRODUCT INFORMATION Press SET to select E2 CT (404A) REFRIG AIR DRYER Serial # B00000 Firmware Rev. 2.38 E3 COMMUNICATIONS MENU Press SET to Select E4 DRAIN SETUP MENU Press SET to select 28 - REV. B SCP 1200 - 3000 USER GUIDE E5 CALIBRATION MENU E6 ALARM REPORTING MENU M1 ALARM #1 HIGH DEWPOINT RELAY PAGER Yes N/A M4 RELAY Yes ALARM #2 FLOW/AUX PAGER N/A ALARM #3 DP PROBE FAULT RELAY PAGER Yes N/A REMOTE N/A REMOTE N/A M7 ALARM #4 MOTOR FAULT RELAY PAGER Yes N/A REMOTE N/A M10 ALARM #1 E3: HI SUPERHEAT RELAY PAGER Yes N/A REMOTE N/A M13 REMOTE N/A M16 ALARM #6 E4: LOW DP/PUMPDOWN RELAY PAGER REMOTE Yes N/A N/A M19 ALARM #8 E6: LOW PRESSURE RELAY PAGER Yes N/A ALARM #7 E5: DRYER OVERLOAD RELAY PAGER Yes N/A M22 REMOTE N/A 29 - REV. B REMOTE N/A SCP 1200 - 3000 USER GUIDE M25 ALARM #9 E7: HIGH(REFRIG)PRESSURE RELAY PAGER REMOTE Yes N/A N/A M28 ALARM #10 W1 : LOW AIR-IN PSI RELAY PAGER REMOTE Yes N/A N/A M31 ALARM #11 W2: HIGH AIR-IN PSI RELAY PAGER Yes N/A REMOTE N/A M34 ALARM #12 W3: CHANGE FILTER RELAY PAGER REMOTE Yes N/A N/A M37 ALARM #13 W4: HIGH AIR-IN ºF M40 ALARM #14 W5: HIGH AMBIENT/H20 RELAY PAGER REMOTE Yes N/A N/A M43 ALARM #15 E9: DRAIN FAULT RELAY PAGER Yes N/A M46 CALIBRATION MENU. Each of the transducers in the system has their ranges set in the “H” series screens. It is important that the value indicated in the screens match the maximum range of the transducer span. If while servicing the dryer, and a different ranged transducer is replacing a factory installed transducer, make certain a corrected value for maximum range is entered in the appropriate screen. 30 - REV. B RELAY Yes H1 ALARM #16 MODEM FAULT PAGER N/A REMOTE N/A REMOTE N/A ENGLISH / METRIC SELECT UNITS: (ENGLISH) SCP 1200 - 3000 USER GUIDE H2 METRIC PRESSURES: BAR OR KP H3 INLET PRESSURE ACTUAL: 93 PSI OFFSET [ 0 psi ] FULLSCALE 200 PSI H4 ACTUAL: OFFSET FULLSCALE INLET PRESSURE 93 PSI [ 0 psi ] 200 PSI H5 Outlet Pressure Actual: Offset: Fullscale 0 psi [ 0 psi ] 200 psi H6 Outlet Pressure Actual: Offset: Fullscale 0 psi 0 psi [ 200 psi ] H7 Discharge Pressure Actual: Offset: Fullscale 3 psi 0 psi [ 600 psi ] H8 Discharge Pressure Actual: 0 psi Offset: 0 psi Fullscale [ 600 psi ] H9 Suction Pressure Actual: Offset: Fullscale 0 psi [ 0 psi ] 600 psi H10 Suction Pressure Actual: 0 psi Offset: 0 psi Fullscale [ 600 psi ] 31 - REV. B SCP 1200 - 3000 USER GUIDE H11 Flow Actual: Offset: Fullscale: OPEN [ 0 scfm ] 100 scfm H12 Flow Actual: Offset: Fullscale: OPEN 0 scfm [100 scfm] H13 AUX #1 Actual: Offset: Fullscale: OPEN [0] 100 H14 AUX #1 Actual: Offset: Fullscale: OPEN 0 [ 100 ] H15 AUX #2 Actual: Offset: Fullscale: OPEN [0] 100 H16 AUX #2 Actual: Offset: Fullscale: OPEN 0 [ 100 ] System Drains- (E & I Series Menus) - Each of the two (2) drain controls can be programmed to be either a `TIMED’ or `DEMAND’ drains. • • • If Timed is selected, the drain will activate to the “Interval” time setting for the period of time indicated in the `Duration’ time setting. If DEMAND is selected, the drain will operate for the period of time indicated in the `Duration’ time setting, when a drain input signal is sensed from the demand drain float. A DRAIN FAULT Alarm can occur if float doesnot respond as expected. When a fault is detected, the drain solenoid will be `pulsed’ for ten minutes in attempt to clear the faulted drain. The `Auto Test’ feature will operate the drain for the period of time indicated in the Duration setting at the specifiedInterval. This feature is intended to prevent sediment buildup by activating the drain periodically and `blowing out’ any possible debris. E4 DRAIN SETUP MENU Press SET to Select I 1 Drain #1 Type Interval (m:s): Duration: 32 - REV. B [ DEMAND ] 10 :00 2 Sec SCP 1200 - 3000 USER GUIDE I 2 Drain #1 Type Interval (m:s): Duration: DEMAND [10]:00 2 Sec I 3 Drain #1 Type Interval (m:s): Duration: DEMAND 10:[00] 2 Sec I 4 Drain #1 Type Interval (m:s): Duration: DEMAND 10:00 [2] Sec I 5 Drain #1 On Delay (m:s) Auto Test (h:m) [0:05] 12:00 I 6 Drain #1 On Delay (m:s) Auto Test (h:m) 0:05 [12]:00 I 7 Drain #1 On Delay (m:s) Auto Test (h:m) I 8 Drain #2 Type: Interval (m:s): Duration: 0:05 12:[00] TIMED 10:00 2 sec I 9 Drain #2 Type: Interval (m:s): Duration: TIMED [ 10 ]: 00 2 sec I 10 Drain #2 Type: Interval (m:s): Duration: TIMED 10:[ 00 ] 2 sec 33 - REV. B SCP 1200 - 3000 USER GUIDE I 11 Drain #2 Type: Interval (m:s): Duration: TIMED 10:00 [ 2 ] sec I 12 Drain #2 On Delay (m:s) Auto Test (h:m) [ 0: 05 ] 12:00 I 13 Drain #1 On Delay (m:s) Auto Test (h:m) [ 0: 05 ] 12:00 I 14 Drain #2 On Delay (m:s) Auto Test (h:m) [ 0: 05 ] 12:00 3. SENSOR SETTINGS-------------------------------------------------------------------------------------SENSOR SETTINGS Press SET to select C1 P1 LOW INLET Value: Alarm Set: C2 P1 HIGH INLET Value: Alarm Set: C3 100 psi 101 psi P4 DISCHARGE Value: Alarm Set: 34 - REV. B 100 psi 50 psi 240 psi 350 psi SCP 1200 - 3000 USER GUIDE C4 FLOW INPUT ENABLE (If Value indicates Fault = No sensor) P5 SUCTION Value: Alarm Set: 100 psi 30 psi C5 FLOW SENSOR Enabled : [ NO ] VALUE: OPEN Alarm Set: 0 scfm FLOW ALARM SET POINT C6 Enabled : VALUE: Alarm Set: FLOW SENSOR C7 Enabled : VALUE: AUX #1 SENSOR NO FAULT [ 0scfm ] C8 AUX #1 ALARM Low Alarm : [0] High Alarm: 100 Delay (m:s): 00.05 C9 AUX #1 ALARM Low Alarm : 0 High Alarm: [ 100 ] Delay (m:s): 00.05 C10 AUX #1 ALARM Low Alarm : 0 High Alarm: 100 Delay (m:s): [ 00.05 ] C11 AUX #2 SENSOR Enabled : [NO] C12 AUX #2 ALARM Low Alarm : High Alarm: Delay (m:s): Value: [ 0] 100 00.05 35 - REV. B [ NO ] OPEN SCP 1200 - 3000 USER GUIDE C13 AUX #2 ALARM Low Alarm : High Alarm: Delay (m:s): 0 [ 100 ] 00.05 C14 AUX #2 ALARM Low Alarm : 0 High Alarm: 100 Delay (m:s): [ 00.05 ] 4. TEMPERATURE SETTINGS---------------------------------------------------------------------------------TEMPERATURE SETTINGS Press SET to select B1 T1: DRYER INLET Value: Alarm Set: B2 T3: DRYER OUTLET Value: Alarm Set: B3 86ºF 120ºF T4: REFRIG. Value: Alarm Set B3 72ºF 120ºF 87ºF 130ºF T4: REFRIG. Value: Alarm Set 87ºF 130ºF 5. VIEW ALARMS-----------------------------------------------------------------------------------------------VIEW ACTIVE ALARMS Press SET to select 36 - REV. B SCP 1200 - 3000 USER GUIDE ACTIVE ALARMS Press UP/DOWN to View active alarms Press RESET to A3a SYSTEM SHUTDOWN – Requires a manual reset. A1 ACTIVE ALARMS HIGH DEWPOINT (Self-Resetting) Press RESET to EXIT A2 ACTIVE ALARMS LOW FLOW (Self-Resetting) Press RESET to EXIT A3 ACTIVE ALARMS E1: DP PROBE OPEN Press RESET to Clear A3b SYSTEM SHUTDOWN – Requires a manual reset. A3 ACTIVE ALARMS E2: DP PROBE SHORT Press RESET to Clear A4 SYSTEM SHUTDOWN – Requires a manual reset. A4 ACTIVE ALARMS MOTOR OVERLOAD Press RESET to Clear A5a SYSTEM SHUTDOWN – Requires a manual reset. A5 ACTIVE ALARMS E3: SUPERHEAT HIGH Press RESET to Clear A5b SYSTEM SHUTDOWN – Requires a manual reset. A5 ACTIVE ALARMS E3: SUPERHEAT LOW Press RESET to Clear A6 A6 SYSTEM SHUTDOWN – Requires a manual reset. ACTIVE ALARMS E4: LOW DEWPOINT Press RESET to Clear 37 - REV. B SCP 1200 - 3000 USER GUIDE A7 SYSTEM SHUTDOWN Requires a manual reset. A7 ACTIVE ALARMS ES: DRYER OVERLOAD Press RESET to Clear A8 SYSTEM SHUTDOWN Requires a manual reset. A8 ACTIVE ALARMS E6: LOW REFRIG/ OIL PSI Press RESET to Clear A9 SYSTEM SHUTDOWN Requires a manual reset. A9 ACTIVE ALARMS E7: HIGH REFRIG PSI Press RESET to Clear A10 ACTIVE ALARMS W1: LOW AIR-IN PSI (Self Resetting) Press RESET to Exit A11 ACTIVE ALARMS W2: HIGH AIR-IN PSI (Self Resetting) Press RESET to Exit A12 ACTIVE ALARMS W3: COALESCER PSID Press RESET to Clear A15a Drain #1 FAILURE A13 ACTIVE ALARMS W4: HIGH AIR-IN ºF (Self Resetting) Press RESET to Exit A14 ACTIVE ALARMS W5: HIGH AMBIENT/H2O (Self Resetting) Press RESET to Exit A15 38 - REV. B ACTIVE ALARMS DRAIN FAULT-1 (Self Resetting) Press RESET to Exit SCP 1200 - 3000 USER GUIDE A15 ACTIVE ALARMS DRAIN FAULT-2 (Self Resetting) Press RESET to Exit A16 ACTIVE ALARMS MODEM FAILURE A15b Drain #2 FAILURE A16 Drain Requires a manual reset. Press RESET to Clear ACTIVE ALARMS No Active Alarms Press RESET to EXIT COMPRESSOR MENU Press SET to Select Auto-Sequence “Time” can be selected between 1 & 72 hours. NOTE: When set to “TEST”, units will sequence STANDBY COMPRESSOR every 3 minutes (also see the K10 Menu in DISPLAY VALUES). SELECT “ENABLE or DISABLE” R4 COMPR #1 COMPR #2 COMPR #3 COMPR #4 R1 COMPR #1 COMPR #2 COMPR #3 COMPR #4 [ ENABLED ] ENABLED ENABLED DISABLED R2 COMPR #1 COMPR #2 COMPR #3 COMPR #4 ENABLED [ ENABLED ] ENABLED DISABLED R3 COMPR #1 COMPR #2 COMPR #3 COMPR #4 ENABLED ENABLED [ ENABLED ] DISABLED ENABLED ENABLED ENABLED [ DISABLED ] R5 AUTO-SWITCH TIME: 24 Hrs 39 - REV. B SCP 1200 - 3000 USER GUIDE 8. Maintenance Charts The maintenance chart below indicates the components that should be checked while performing routine maintenance on the dryer. The chart also indicates how often a specific check should be done. Description of Service Required Component Filtration Operation Week Month 6 Months Year Coalescing Filter Element Dryer Condensing Coil (AC units) Dryer Condenser (WC units)* Dryer Drain Line Y-Strainer Dryer High Pressure Switch Dryer Low Pressure Switch* Dryer Fan Control Switches (AC units) Dryer Compressor Oil Level Filtration Service recommended every: Drain Solenoid Check Replace * The condenser should be cleaned only if the unit is running abnormally high discharge pressure. Contact the factory for verification prior to proceeding with this maintenance item. 8.1 Maintenance Procedures Before performing any maintenance on the machine ensure that air pressure is vented from the system. Also make sure that personnel performing the mainte nance have read the maintenance section of the manual. Some of the maintenance tasks will require the refrigeration system to run, but when not required, turn the unit off before proceeding. Upon completion of the maintenance tasks be sure that the machine has been properly reassembled prior to restarting and reintroducing air. 40 - REV. B SCP 1200 - 3000 USER GUIDE 8.2 Routine Maintenance This section covers the various components that require periodic maintenance and/or replacement. Coalescing Filter Element The coalescing filter element should be check Bi-Annually. On units with the standard control panel, check the pressure drop across the unit by using air pressure gauges upstream and downstream of the dryer using the closest possible gauges to the dryer. If it is determined that there is a high pressure drop across the machine, remove the filter element from the machine and inspect it. If the filter is dirty, replace it. Ensure that air pressure is removed from the machine prior to removing the filter element. On units that have the Control Center option installed the filter differential can be checked on the control board. The coalescing element should be changed annually. To change the filter element: • • • • • • • • De-pressurize the dryer. Remove the bolts that secure the filter housing cover. Remove the wing nut that secures the filter cap to the element. Remove the filter cap. Remove the existing element from the housing. Install the replacement element. Reinstall the filter cap and wing nut Reinstall the filter cover. Condensing Coil (Air Cooled Units) The condensing coil should be cleaned weekly. Ensure that air pressure is removed from the system prior to cleaning the condenser. The condenser can be cleaned by using a vacuum or compressed air. If the condenser is not clean after it is blown out with compressed air or vacuumed, contact the factory for assistance. Condenser (Water Cooled Units) The water cooled condenser should be checked and cleaned annually if necessary. To check the condenser, water flow to the condenser should be shut off, air flow to the machine should be shut off, and the unit should be taken out of a run mode. The end bonnets then need to be removed exposing the tube side of the condenser. The tube side should be inspected for any debris and cleaned. If soft deposits are found they can be cleaned using a pneumatic tube cleaning gun which forces plugs down the tubes. Some have a brush between two rubber plugs and others are specially designed plugs which scrape the tube walls as they travel down the tube. If scale is found special equipment is required to clean the tubes. These cleaning systems utilize a flexible shaft which rotates a brush as it is fed 41 - REV. B SCP 1200 - 3000 USER GUIDE down the tube, they can also simultaneously flush out the tubes with water. There is a wide variety of brushes and tools available that attach to the shaft to clean both soft and hard deposits. Drain Line Y-Strainer (See Section 5.0, Fig. 4) The drain line y-strainer should be cleaned weekly. Air flow and air pressure should be removed from system before proceeding. To clean the y-strainer: • Turn the ball valve on the strainer assembly to the closed position • Remove threaded cap at the end of the ball valve assembly. • Clean the screen inside of the cap by rinsing it under water. • Reinstall the screen and cap • Return the ball valve to the open position High Pressure, Low Pressure, & Fan Control (AC units only) The refrigeration pressure switches should be checked monthly to ensure that they are adjusted to the proper settings. Please refer to the applicable electrical drawings for your unit. Compressor Oil Level The oil level in the compressor should be checked daily. The refrigeration system should never need oil unless the system is leaking or has been recently repaired. If it is determined that the system needs oil, do the following: • Run the dryer for a minimum of 2 minutes, if there is not a visible level of oil in the sight glass, proceed to the next step, if there is an oil level, DO NOT add oil to the system. • Using the appropriate oil pump add the proper oil (POE forR134 and R404 refriger ant) using the Schrader valve on the suction side of the compressor. • Add oil until there is a visible level in the sight glass with the compressor running. 42 - REV. B SCP 1200 - 3000 USER GUIDE Maintenance Log Service Performed Date Parts Replaced 43 - REV. B Initials SCP 1200 - 3000 USER GUIDE Maintenance Log Service Performed Date Parts Replaced 44 - REV. B Initials SCP 1200 - 3000 USER GUIDE 9. Associated Drawings 45 - REV. B SCP 1200 - 3000 USER GUIDE 46 - REV. B SCP 1200 - 3000 USER GUIDE 47 - REV. B SCP 1200 - 3000 USER GUIDE 48 - REV. B SCP 1200 - 3000 USER GUIDE 49 - REV. B SCP 1200 - 3000 USER GUIDE 50 - REV. B SCP 1200 - 3000 USER GUIDE 51 - REV. B SCP 1200 - 3000 USER GUIDE 52 - REV. B SCP 1200 - 3000 USER GUIDE 53 - REV. B SCP 1200 - 3000 USER GUIDE 54 - REV. B SCP 1200 - 3000 USER GUIDE 55 - REV. B SCP 1200 - 3000 USER GUIDE 56 - REV. B SCP 1200 - 3000 USER GUIDE 57 - REV. B SCP 1200 - 3000 USER GUIDE 58 - REV. B SCP 1200 - 3000 USER GUIDE 59 - REV. B SCP 1200 - 3000 USER GUIDE 60 - REV. B SCP 1200 - 3000 USER GUIDE 61 - REV. B SCP 1200 - 3000 USER GUIDE 62 - REV. B SCP 1200 - 3000 USER GUIDE 63 - REV. B SCP 1200 - 3000 USER GUIDE 64 - REV. B SCP 1200 - 3000 USER GUIDE 65 - REV. B SCP 1200 - 3000 USER GUIDE 66 - REV. B SCP 1200 - 3000 USER GUIDE 67 - REV. B SCP 1200 - 3000 USER GUIDE 68 - REV. B SCP 1200 - 3000 USER GUIDE 69 - REV. B SCP 1200 - 3000 USER GUIDE 70 - REV. B SCP 1200 - 3000 USER GUIDE 71 - REV. B SCP 1200 - 3000 USER GUIDE 72 - REV. B SCP 1200 - 3000 USER GUIDE 73 - REV. B SCP 1200 - 3000 USER GUIDE 74 - REV. B SCP 1200 - 3000 USER GUIDE 75 - REV. B SCP 1200 - 3000 USER GUIDE 76 - REV. B SCP 1200 - 3000 USER GUIDE 77 - REV. B SCP 1200 - 3000 USER GUIDE 78 - REV. B SCP 1200 - 3000 USER GUIDE 10. Spare Parts List STD. MODEL (scfm) Replacement parts 1200 1500 2000 2500 *DP16255 (AC) DP16240-4-1 (WC) DP16260-4 DP16280-4 3000 Compressor 460V/3PH/60Hz DP16292-404 Fan motor 460V/1PH/60Hz (460V Dryers) *DP18184 DP18192 DP205-16-M Fan motor starter contactor N/A ES5003-5 Starter overload relay N/A ES5001-2.4 Fan blade *DP18158-B DP18185-B DP205-16-B Fan guard *DP18158-G DP18184-G DP205-16-G Condenser coil (Air-Cooled) *DP14407-C DP14422-1-C DP205-16 Water regulating valve (watercooled only) Suction line solenoid valve DP38110 DP38115 N/A DP38120 DP32121 DP32126-H Suction line solenoid coil N/A DP32084-C DP32301 Unloader solenoid valve DP32100-H DP32110-H DP32115-H Liquid line solenoid valve DP32086-1 DP32100-H Unloader/liquid line solenoid coil Expansion valve DP32110-H DP32301 DP32301 DP34185-404 Refrigerant suction filter DP28305 Refrigerant liquid line drier DP28135 DP34201-4 DP33011-4 DP28315-B (replaceable core) DP28135 DP28315-C (replaceable core) Fan #1 pressure switch DP40080 Fan #2 pressure switch DP40081 DP40051 (AC) / DP401030 (WC) High refrigerant pressure switch DP40026 (AC) / DP401030 (WC) Low refrigerant pressure switch Dual air pressure gauge Electronic controller Dew point temperature probe DP33012-4 DP42100-P DP42100-P DP5550 DP5550 DP5060-P12 DP5060-P15-1 DP5060-P18 DP5060-P18 DP5060-S DP5060-S Air inlet temperature probe DP5060-T15 DP5060-P15 Ambient or Water temperature probe DP5060-T15 DP5060-P15 Superheat probe TP2455 TP2455 Demand drain level sensor DP6060-S DP6060-S Replacement filter element Refrigerant pressure transducer JE1600-C10 JE1600-C10 Upper Drain solenoid valve #1 TP8002 TP8002 Lower Drain solenoid valve #2 TP8002-1 TP8003 JE3000-C10 TP8005-1 TP8005-1 TP8101-1P N/A Actuated drain ball valve TP6605-5 KP5025-S Valve strainer screen Compressor contactor (3) JE1000-C10 ES5035 N/A ES5035 ET0150 Transformer (Control) * Starting with serial # 120602860 and higher. 79 - REV. B DP5060-P18 ES5050 SCP 1200 - 3000 USER GUIDE 11. Warranty and Product Registration 80 - REV. B Worldwide Filtration Manufacturing Locations North America Europe Asia Pacific Filtration & Separation/Balston domnick hunter Filtration & Separation Castle Hill, Australia +61 2 9634 7777 www.parker.com/australia Compressed Air Treatment Haverhill, MA 978 858 0505 www.parker.com/balston Finite Airtek Filtration Airtek/domnick hunter/Zander Lancaster, NY 716 686 6400 www.parker.com/faf Finite Airtek Filtration/Finite Oxford, MI 248 628 6400 www.parker.com/finitefilter Engine Filtration & Water Purification Racor Modesto, CA 209 521 7860 www.parker.com/racor Holly Springs, MS 662 252 2656 www.parker.com/racor Beaufort, SC 843 846 3200 www.parker.com/racor Racor – Village Marine Tec. Gardena, CA 310 516 9911 desalination.parker.com Parker Sea Recovery Carson, CA 310 637 3400 www.searecovery.com Hydraulic Filtration Hydraulic Filter Metamora, OH 419 644 4311 www.parker.com/hydraulicfilter Laval, QC Canada 450 629 9594 www.parkerfarr.com Process Filtration domnick hunter Process Filtration Oxnard, CA 805 604 3400 www.parker.com/processfiltration Madison, WI 608 824 0500 www.scilog.com Phoenixville, PA 610 933 1600 www.parker.com/processfiltration Aerospace Filtration Velcon Filtration Colorado Springs, CO 719 531 5855 www.velcon.com Compressed Air Treatment Gateshead, England +44 (0) 191 402 9000 www.parker.com/dhfns Parker Gas Separations Etten-Leur, Netherlands +31 76 508 5300 www.parker.com/dhfns Hiross Zander Padova Business Unit Padova, Italy +39 049 9712 111 www.parker.com/hzd Hiross Zander Essen Business Unit Essen, Germany +49 2054 9340 www.parker.com/hzd Engine Filtration & Water Purification Racor Dewsbury, England +44 (0) 1924 487 000 www.parker.com/rfde Racor Research & Development Stuttgart, Germany +49 (0)711 7071 290-10 www.parker.com/rfde Hydraulic Filtration Hydraulic Filter Arnhem, Holland +31 26 3760376 www.parker.com/hfde Urjala Operation Urjala, Finland +358 20 753 2500 www.parker.com/hfde Australia China Shanghai, China +86 21 5031 2525 www.parker.com/china India Navi Mumbai, India +91 22 651 370 8185 www.parker.com/india Parker Fowler Bangalore, India +91 80 2783 6794 www.johnfowlerindia.com Japan Tokyo, Japan +81 45 870 1522 www.parker.com/japan Parker Techno Osaka, Japan +81 66 340 1600 www.techno.taiyo-ltd.co.jp Korea Hwaseon-City +82 31 359 0852 www.parker.com/korea Singapore Jurong Town, Singapore +65 6887 6300 www.parker.com/singapore Thailand Bangkok, Thailand +66 2186 7000 www.parker.com/thailand Condition Monitoring Centre Latin America Parker Kittiwake Sao Paulo, Brazil +55 12 4009 3500 www.parker.com/br Norfolk, England +44 (0) 1842 763 299 www.parker.com/hfde West Sussex, England +44 (0) 1903 731 470 www.kittiwake.com Parker Procal Peterborough, England +44 (0) 1733 232 495 www.kittiwake.com Process Filtration domnick hunter Process Filtration Birtley, England +44 (0) 191 410 5121 www.parker.com/processfiltration Parker Comercio Ltda. Filtration Division Pan American Division Miami, FL 305 470 8800 www.parker.com/panam Africa Aeroport Kempton Park, South Africa +27 11 9610700 www.parker.com/africa Parker Twin Filter BV Zaandam, Netherlands +31(0)75 655 50 00 www.twinfilter.com ©2013 Parker Hannifin Corporation. Product names are trademarks or registered trademarks of their respective companies Parker Hannifin Corporation Finite Airtek Filtration Division 4087 Walden Avenue Lancaster, NY 14086 phone 716 686 6400 www.parker.com/faf PUB042209 REV B ">
/
Download
Just a friendly reminder. You can view the document right here. But most importantly, our AI has already read it. It can explain complex things in simple terms, answer your questions in any language, and help you quickly navigate even the longest or most compilcated documents.
Advertisement