DCS Thyristor Power Converters for DC Drive Systems 25 to 5150 A Service Manual DCS 500 DCS 600 4 2 3 1 How to use the DCS Documentation System The matrix below indicates all available product documentation and its corresponding order numbers on its left columns as well as all existing DC Drive systems on its top rows. System descriptions, Technical data and Operating instructions (as far as they are available for the corresponding drive) are the basic documents and will be delivered together with each drive. All other documentation has to be ordered separately. Language Language Operating Instructions 3ADW000055 3ADW000080 3ADW000091 (Installation) EN,DE,FR,SP EN, DE EN, DE Software description 3ADW000078 3ADW000076 3AST000953 ➂ EN EN EN Tools 3AFE61178775 CMT/DCS500 EN 5926915-1 GAD 3ADW000048 (Application blocks) 3AFY61296123 Drive Window EN EN EN EN Service Instructions 3ADW000093 3ADW000131 EN, DE EN Fieldbus 3ADW000086 3ADW000097 EN EN Others 3ADW000115 12-Pulse operation 3ADW000092 Rebuild manual 3ADW000128 Paralleling DCS Conv. 3ADW000040 12-Puls operation Language Language Language Language Language EN EN EN EN, DE DCR DCS/DCF 500B x DCS 400 x DCS 400 Easy Drive DCS 600 CraneDrive x x DCS/DCF 600 MultiDrive x x Rebuild Module x x x x x x x x x x Volume III Volume IV A IV F IV F1 Volume V D1 VF Volume V A2 - Volume VI A VI K Volume - Volume VIII F2 XI H1 VIII D1 VIII A2 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x available only for: DCS 500B / 600 drive systems EN Volume II D II F II F1 II K II F Cubicle DCS 500 Easy Drive Technical Data 3ADW000165 Language Standard Drive Module DCA 500 / DCA 520 EN, DE,FR EN, DE EN EN,DE,FR,IT,SP EN EN, DE EN, DE,FR,IT,SP EN DCA 620 Product documentation System description 3ADW000066 3ADW000072 3ADW000121 ➀ 3ADW000095 (Manual) ➁ 3ADW000139 3ADW000071 (Flyer) 3ADW000152 3ADW000173 (Flyer) DCA 600 Cubicle DCE 400 System Drive DC drive systems x x x x x x x x x x x x x x x x Status: 25.March.2002 ➀ Covers information of Technical data ➁ Covers information of Technical data, Operating Instructions, Software Description ➂ Covers information of Operating Instructions, Software Description Note: For clearness the type designation in this brochure is shown in the following way: Designation DCS 500 DCS 600 is valid for DCS 500 DCS 500B DCS 600 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Thyristor Power Converters Series DCS 500 / DCS 500B DCS 600 25 to 5150 A Service Manual Code: 3ADW 000 093 R0601 Rev F S_M_E_F.DOC EFFECTIVE: Jul. 4th, 2002 SUPERSEDES: Rev E Oct. 26th, 2001 2002 ABB Automation Products GmbH. All rights reserved. 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Safety Instructions Overview This chapter contains safety instructions which must be complied with during installation, operation and maintenance of the power converters series DCS 500 or DCS 600. If these instructions are not complied with, this may result in injuries (perhaps even with fatal) or in damage to the power converter, the motor and the driven machine. Before starting with any work whatsoever at or with this unit, you must read the information given in this chapter. Warnings Warnings provide information on states which if the specified procedure for the state concerned is not meticulously complied with may result in a serious error, in major damage to the unit, in injury to persons and even in death. They are identified by the following symbols: Danger: High Voltage! This symbol warns you of high voltages which may result in injuries to persons and/or damage to equipment. Where appropriate, the text printed adjacent to this symbol describes how risks of this kind may be avoided. ● ● ● ● All electrical installation and maintenance work on the thyristor power converter must be carried out by properly qualified staff who have been thoroughly trained in electrical engineering. The thyristor power converter and its adjacent units must be properly earthed by qualified professionals. You must NEVER perform any work on the thyristor power converter while it is still switched on. First switch the unit off, use a measuring instrument to make absolutely sure that the power converter has really been de-energized, and only then you may start with the work concerned. Due to external control circuits, there may be dangerously high voltages present at the thyristor power converter even after the line voltage has been switched off. So always work at the unit with appropriate caution! Non-compliance with these instructions may result in injury (or even death!). DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f i Safety Instructions General warning: this symbol warns you of nonelectrical risks and dangers which may result in serious or even fatal injury to persons and/or in damage to equipment. Where appropriate, the text printed adjacent to this symbol describes how risks of this kind may be avoided. ● When thyristor power converters are in use, the electric motors, power transmission elements and the driven machines are working in an extended operating range, which means they have to cope with a relatively high loading. ● You should have made sure that all units, devices and appliances used are actually suitable for this higher loading. ● If you have to operate the thyristor power converter at a rated motor voltage and/or a rated motor current significantly below the figures stated in the thyristor power converter's output data, you must take appropriate precautionary measures to protect the unit against overspeed, overload, breakage, etc., by modifying the software or hardware appropriately. ● For insulation testing, you must disconnect all cables from the thyristor power converter. You should avoid operating your unit at values other than the rated data. Non-compliance with these instructions may cause lasting damage to the thyristor power converter. ● The thyristor power converter possesses a number of automatic reset functions. When these functions are executed, the unit will be reset after an error and will then resume operation. These functions should not be used if other units and devices are not suitable for an operating mode of this kind, or if their use might entail dangerous situations. Warning of electrostatic discharge: this symbol warns you against electrostatic discharges which may damage the unit. Where appropriate, the text printed next to this symbol describes how a risk of this kind may be avoided. ii DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Safety Instructions Notes Notes supply information on states requiring particular attention, or indicate that additional information is available on a specific topic. For this purpose, the following symbols are used: CAUTION! Cautions are designed to draw your attention to a particular state of affairs. Note A note contains or refers you to additional information available on the particular topic concerned. Mains connection You can use a switch disconnector (with fuses) in the power supply of the thyristor power converter to disconnect the electrical components of the unit from the power supply for installation and maintenance work. The type of disconnector used must be a switch disconnector as per EN 60947-3, Class B, so as to comply with EU regulations, or a circuit-breaker type which switches off the load circuit by means of an auxiliary contact causing the breaker's main contacts to open. The mains disconnector must be locked in its "OPEN" position during any installation and maintenance work. EMERGENCY STOP buttons EMERGENCY STOP buttons must be installed at each control desk and at all other control panels requiring an emergency stop function. Pressing the STOP button on the CDP 31x control panel of the thyristor power converter will neither cause an emergency motor stop, nor will the drive be disconnected from any dangerous potential. To avoid unintentional operating states, or to shut the unit down in case of any imminent danger according to the standards in the safety instructions it is not sufficient to merely shut down the drive via signals „RUN“, „drive OFF“ or „Emergency Stop“ respectively „control panel“ or „PC tool“. Intended use The operating instructions cannot take into consideration every possible case of configuration, operation or maintenance. Thus, they mainly give such advice only, which is required by qualified personnel for normal operation of the machines and devices in industrial installations. If in special cases the electrical machines and devices are intended for use in non-industrial installations - which may require stricter safety regulations (e.g. protection against contact by children or similar) -, these additional safety measures for the installation must be provided by the customer during assembly. DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f iii Safety Instructions iv DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Contents VI A SERVICE MANUAL Safety Instructions Chapter 1 - Introduction How to use this manual......................................................................................................... 1-1 Contents of this manual ........................................................................................................ 1-1 Target group ......................................................................................................................... 1-2 Associated publications........................................................................................................ 1-2 Storage and transport ........................................................................................................... 1-2 Rating plate and type code ................................................................................................... 1-2 Chapter 2 - Fault Tracing Thyristors How to detect, if a thyristor is faulty....................................................................................... 2-1 A fuse is blown .......................................................................................................... 2-1 Ripple monitor ........................................................................................................... 2-1 How to find a faulty thyristor.................................................................................................. 2-2 Converters size C1 and C2/C2b (25...1000 A)........................................................... 2-2 Blown fuses ............................................................................................................... 2-2 Converters size A5, C3 and C4 (900...5150 A) .......................................................... 2-3 Blown fuses ............................................................................................................... 2-3 Ripple monitor ........................................................................................................... 2-3 Chapter 3 - Handling the Semiconductors General Instruction how to handle the Semiconductors ........................................................ 3-1 Chapter 4 - Exchange of Thyristors for Sizes C1/C2/C2b Installation of thyristor modules in converters size C1/C2/C2b (25...1000 A) ........................ 4-1 Required Tools .......................................................................................................... 4-1 Remove faulty thyristor modules................................................................................ 4-1 Install new thyristor modules...................................................................................... 4-2 Thyristor module location........................................................................................... 4-3 Module terminals ....................................................................................................... 4-8 Chapter 5 - Exchange of Thyristors for Size A5 Installation of "Disc Type" thyristor in converters size A5 (900...2000 A)............................... 5-1 Required Tools .......................................................................................................... 5-1 Find faulty thyristor .................................................................................................... 5-2 Remove faulty thyristor .............................................................................................. 5-3 Install new thyristor .................................................................................................... 5-4 Chapter 6 - Exchange of Thyristors for Size C3 Installation of "Disc Type" thyristor in converters size C3 (900...2000 A) .............................. 6-1 Required Tools .......................................................................................................... 6-1 Remove faulty thyristor .............................................................................................. 6-2 Find faulty thyristor .................................................................................................... 6-2 DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f v Contents Install new thyristor.................................................................................................... 6-3 Fasten the clamp ....................................................................................................... 6-3 Chapter 7 - Exchange of Thyristors for Size C4 Installation of "Disc Type" thyristor in converters size C4 (2050...5150 A) ............................ 7-1 Required Tools .......................................................................................................... 7-1 Find faulty thyristor .................................................................................................... 7-2 Install new thyristor.................................................................................................... 7-3 Chapter 8 - Compatibility of SDCS-PIN-2 boards Description of SDCS-PIN-20xB boards ................................................................................. 8-1 Hardware coding ....................................................................................................... 8-1 Snubber circuit........................................................................................................... 8-1 Compatibility of SDCS-PIN-20x boards ..................................................................... 8-2 Compatibility of SDCS-PIN-20x and SDCS-PIN-2x boards........................................ 8-2 Change SDCS-PIN-2x boards ................................................................................... 8-3 Chapter 9 - Preventive Maintainance Recommended regular maintenance .................................................................................... 9-1 Air Filters ................................................................................................................... 9-1 Cooling air pressure switch in converter modules type C4......................................... 9-1 Fan ............................................................................................................................ 9-1 Heatsink .................................................................................................................... 9-1 Internal high current connections in converters type C4 ............................................ 9-2 Relays and electrical connections.............................................................................. 9-2 Appendix A - Spare Parts List vi DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Chapter 1 - Introduction How to use this manual The purpose of this service manual is to provide detailed information on how to service power converters from the DCS 500 or DCS 600 series. Note: If it is not mentioned explicitly all details given in this Service Manual will be valid for both,series DCS 500 and series DCS 600! Contents of this manual Chapter 1 - Introduction This chapter informs about the contents and the use of this manual as well as the boundary conditions applying and the thyristor power converter rating plate. Chapter 2 - Fault Tracing Thyristors This chapter describes how to detect and select a faulty thyristor. Chapter 3 - Handling the Semiconductors This chapter describes the handling of thyristors and thyristor modules. Chapter 4 - Exchange of Thyristors of Sizes C1/C2/C2b This chapter describes the exchange of thyristors in converters sizes C1/C2. Chapter 5 - Exchange of Thyristors of Size A5 This chapter describes the exchange of thyristors in converters size A5. Chapter 6 - Exchange of Thyristors of Size C3 This chapter describes the exchange of thyristors in converters size C3. Chapter 7 - Exchange of Thyristors of Size C4 This chapter describes the exchange of thyristors in converters size C4. Chapter 8 - Compatibility of SDCS-PIN-2 boards This chapter describes the compatibility, utilization and removing/mounting of power interface boards PIN-2x/PIN-20x. Chapter 9 - Preventive Maintainance This chapter describes the measures for preventive maintenance of the thyristor converters. Appendix A - Spare Parts list The Appendix A contains the spare parts list of the converters. DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f VI A 1 - 1 Chapter 1 - Introduction Target group This manual is designed to help those responsible for planning, installing, starting up and servicing the thyristor power converter. These people should possess • basic knowledge of physics and electrical engineering, electrical wiring principles, components and symbols used in electrical engineering, and • basic experience with DC drives and products. Associated publications The DCS 500 or DCS 600 documentation includes the following: Technical Data DCS Thyristor Power Converter Operating Instructions System Description DCS 500 and DCS 500B System Description DCS 600 CAUTION! The thyristor power converter weighs quite a lot and should therefore not be held by the front cover. Please put the unit down only on its back (sizes C1 to C3). Always use due care when handling the unit, so as to avoid injuries or damage. Storage and transport If the unit had been in storage prior to installation or is transported to another location, care must be taken to ensure that the environmental conditions are complied with (see "System Descriptions"). Rating plate and type code For purposes of identification, each thyristor power converter is fitted with rating plates, stating the type code and the serial number, which serve for each unit's individual identification. The type code contains information on the characteristics and the configuration of the unit. Figure 1-1 VI A 1 - 2 Example of a rating plate DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Chapter 1 - Introduction System Des. Rev. OEM D C S 5 0 1 B 0 9 0 0 - 5 1 - 2 1 0 2 0 5 0 - 0 0 0 0 0 0 0 0 0 DC Drives Type S = Standard F = Fieldexciter Product family 50 = DCS500 converter module 60 = DCS600 converter module Bridge type 1 = single (2-Q) 2 = double (4-Q) Version (Salestyp) B = modules with SDCS-CON-2 - = for all DCS600/DCF600 Type (Rated DC 4-Q-current (IP00)) Rated AC voltage 4 = 220...400V 5 = 415...500V 6 = 525...600V 7 = 660...690V 8 = 700...830V 9 = 800...999V 1 = 1190V Frequency 1 = 50/60 Hz Power connection (C4 or A7) - = no option (size C1...A6) R = on the right L = on the left Option Softwaretyp 15 = Multidrive 18 = Crane drive 21 = OEM Control panel 0 = no panel P = panel included Fieldexciter 0 = no field exciter 1 = SDCS-FEX1 2 = SDCS-FEX2.. Fan voltage 0 = standard 5 = 400-500V only size A6/7 6 = 525-690V only size A6/7 Communication boards 0 = no communication board 5 = SDCS-COM5-board A = SDCS-AMC-DCx-board C = SDCS-AMC-DC-Clasx-board Coated version 0 = no coating X = coated version Special Options UL-approval 0 = standard module with UL-certificaion U = modification for UL-certification (C3, A6/7) Interfaces 0 = no fieldbus module included Current measurement modification 0 = no modification C = CMA-2 included M = Paralleling Master converter S = Paralleling Slave converter Voltage measurement modification 0 = no modification 5 = PIN=51 modified for 500 V 6 = PIN=51 modified for 600 V 7 = PIN=51 modified for 700 V 8 = PIN=51 modified for 800 V 9 = PIN=51 modified for 1000 V A = PIN-51 modified for 235V B = PIN-51 modified for 120V C = PIN-51 modified for 70V D = PIN-51 modified for 40V X = Galvanic Isolation Special Customer Software 000= Standard Design revision Thyristor type (only for disc types) 1 = ABB Lenzburg 2 = Eupec Design rev. index only used for internal informations Figure 1-2 Type code DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f VI A 1 - 3 Chapter 1 - Introduction The technical data and specifications are valid as of going to press. ABB reserves the right to make subsequent alterations. If you have any questions concerning your drive system, please contact your local ABB agent. VI A 1 - 4 DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Chapter 2 - Fault Tracing Thyristors How to detect, if a thyristor is faulty Thyristor problems can be noticed by two ways: A fuse is blown This is an indication, that a strong overcurrent has happened due to one of the following reasons: - An internal short circuit between the phases (line side) because of a defect thyristor (short circuit inside a thyristor from anode to cathode). - An internal short circuit between the phases (line side) because of circulating current in a 4-Q converter (malfunction of the control electronics, no thyristor defect). - An external short circuit at the DC terminals of the converter without sufficient impedance. - A commutation fault during inverting mode operation (active braking with high current, high EMF and with low AC voltage). Ripple monitor The ripple monitor indicates, that the ripple of the DC current is much higher than normal. In such a case, most often one thyristor does not work. It´s missing current contribution causes a deep dip in the direct current. The structure of the current loop, the current controller will force the other thyristors to compensate the dip by a certain overcurrent in order to keep the average current constant. Such a compensation results in a ripple monitoring fault during motoring mode operation with α ≤ 90°. During braking or inverting mode operation most often fuses are blown. The reason for a currentless thyristor may be: - A fuse has disconnected one of the six thyristors. This is possible only for converters with 900...5150 A (six internal branch fuses). A converter with three external fuses stops working completely at once when one of the three AC input fuses interrupts a phase input of the converter. - A thyristor does not get firing pulses. - The current controller may be totally mismatched to the DC load. - The AC mains network is causing that fault message. In this case, asymmetrical phase shift, uneven phase voltage or critical designed power factor correction equipment or harmonic reduction equippment can be the reason. DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f VI A 2 - 1 Chapter 2 - Fault Tracing Thyristors How to find a faulty thyristor If a blown fuse is suspected in the converter, the problem is caused most often by a faulty thyistor. To make sure, that a thyristor is the reason and needs to be exchanged fault tracing must be done in two different ways, depending on the size of the converter. In general, make sure, that all safety instructions, given within this manual or within the safety instructions, related to the machine or the application itself, are obeyed. Converters size C1 and C2/C2b (25...1000 A) These converters require semiconductor fuses in the 3 AC lines. - The converter must be disconnected from the mains. - One motor armature cable should be disconnected from the converter. Blown fuses - Using the OHM function of a normal multimeter, measurements must be made from each AC terminal to each DC terminal (U1 to C1, V1 to C1, W1 to C1, U1 to D1, V1 to D1 and W1 to D1; see Figure 4-3). Normally, every measurement should show high resistance (> 1 kΩ). Target: find a short circuit, indicated by low resistance ( <1 Ω ) (destroyed thyristor). - If the converter is designed with half-bridge thyristor modules, then a module consists of two antiparallel thyristors. In this case it is sufficient to know which thyristor pair or module has a defective thyristor because the complete module must be replaced. - After a thyristor module is replaced, the above mentioned measurement should be done another time to make sure that all faulty thyristors have been detected! Note VI A 2 - 2 The RC circuit could also cause 0 Ω result for a short time. The measurement, showing less resistance than 1 Ω should be made a second time with test leads applied to the terminals with the opposite polarity; if this measurement shows the same result, one or two thyristors located in that path are faulty; they need to be replaced. DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Chapter 2 - Fault Tracing Thyristors Converters size A5, C3 and C4 (900...5150 A) These converters are equipped with fuses in the branches of the power part. - The converter must be disconnected from the mains. Blown fuses - In case of a blown fuse, the faulty thyristor or the faulty pair of thyristors are already isolated at one side from the others and therefor the faulty branch is known (see Figure 4-4). - The OHM test should be performed, when the thyristor is still clamped. Outside the converter a special thyristor clamping device is needed. - For 4-Q converters with antiparallel thyristors: The selection of a forward or reverse thyristor is done during the disassembly. Continue with related chapter 5, 6 or 7 Find faulty thyristor - After a thyristor was replaced, the OHM test should be done another time to make sure that all faulty thyristors have been detected! If the motor is still connected to the converter the result of the measurement may be wrong. Ripple monitor If the ripple monitor fault occured, the fault tracing must be adapted to the reasons listed before: - Check the fuses and the thyristors, according to the statements before. - If the power section seems to be ok, but still one or more thyristors don´t take current, something went wrong in between the firing pulse generation and the thyristor´s gate; in this case check: • Is a firing pulse present on the primary side of the firing pulse transformer? • Is a firing pulse present on the secondary side of the firing pulse transformer? • Is the firing pulse transfered to the gate of the thyristor? Are there all electrical connections still healthy? • Can the thyristor be fired with the applied firing pulse? Is the pulse form of the firing pulse identical at all measuring positions? - Check the settings of the current controller. - Check the AC mains network by taking recordings of the line voltage and current at all 3 phases at the same time. DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f VI A 2 - 3 Chapter 2 - Fault Tracing Thyristors VI A 2 - 4 DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Chapter 3 - Handling the Semiconductors General Instruction how to handle the Semiconductors Thyristor modules, busbars and fuses have to be mounted with the correct torque using a torque screw driver or torque wrench. Disc type thyristors in converters size C3 (900...2000 A DC) are normally mounted using a dial gauge, for repair reasons, they can be mounted using a torque wrench. In converters sizes A5 (900...2000 A DC) and C4 (2050...5150 A DC) the mounting force is indicated by an indicating spring welded to the mounting clamp, which is inside the unit. Always mark suspected damaged components clearly after removing them from the circuit, to avoid confusion with "good" components. When removing a damaged semiconductor, write down how and where it was installed (direction, location and connected gate leads). Check that the new and old component have the same type designation or that the new component can replace the old one. A semiconductor can be replaced by different compatible semiconductor according to the codes in the manufacturers' table. Semiconductor components are high-precision products. All unnecessary used tools and objects might damage the easily dented and scratched surfaces of the semiconductors. 1. Keep new semiconductors as long as possible in their original packages. 2. Use protective gloves if possible. 3. Clean work area and hands frequently. 4. Use good illumination. DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f VI A 3 - 1 Chapter 3 - Handling the Semicinductors VI A 3 - 2 DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Chapter 4 - Exchange of Thyristors for Sizes C1/C2/C2b Installation of thyristor modules in converters size C1/C2/C2b (25...1000 A) Required Tools All DCS 500 and DCS 600 size C1/C2/C2b are equipped with thyristor modules. In order to keep the operating temperature of the semiconductor module low, the joint between the heat sink and the module should have a good heat conducting ability. The electrical conductivity of the connectors must also be good. For this reason the following instructions must be observed with particular care. Special tools or material needed in addition to standard tools for the exchange of thyristor modules: - torque spanner: mounting torques for thyristor module to heat sink and elelectrical connections see table “Nominal mounting torques for thyristor modules” in this chapter; - screws are metric type; use appropriate nuts - tissue paper / solvent - thermal joint compound: type BERULUB FZ1 E3 (grease) Manufacturer: ABB Service: Carl Bechem GmbH, 58089 Hagen GHSN 390 011 P 0051 Before the work is started, disconnect the converter from the power supply completely, then check the voltage free condition and make sure, everythingis located in an electrical and mechanical safe condition! Remove faulty thyris- tor modules - Tilt out the electronics casing. Remove the gate leads from the faulty thyristor module and mark the position of the trigger connections on the cable. Remove only as many parts as is needed around the faulty module. If the current transformer must be removed, mark the position and the connections! Remove the faulty thyristor module and mark it. DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f VI A 4 - 1 Chapter 4 - Exchange of Thyristors for Sizes C1/C2/C2b Install new thyristor modules - Remove old thermal joint compound (grease) from the heat sink. Preparation of the heat sink: if the area is clean, spread out the heat-conducting compound with a rubber spatula or by hand. If the area is dirty, clean the heat sink surface with tissue paper. Clean the mounting surfaces with an appropriate solvent (e.g. ethanol). - Apply a thin coat of thermal joint compound to the new module. Spread the thermal joint compound evenly by moving the module forward and backward on the heat sink. - Tighten the clamping screws by hand until the screw heads touch the bottom of the module. Then tighten the screws to 2.5 Nm torque. If the module is mounted using four screws, tighten the screws crosswise. - Tighten the screws to nominal torque (see Table below). - Reinstall the busbars; make sure, the correct torque is applied and reconnect all cables. Thyristor module Nominal mounting torques Size Type Electrical connections Module to heat sink 20 mm block SKKT….. 3 Nm 5 Nm 34 mm block SKKT….. 5 Nm 5 Nm 34 mm block TT….. 6 Nm 6 Nm 50 mm block SKKT….. 9 Nm 5 Nm 50 mm block TT….. 12 Nm 6 Nm 50 mm block (single thyrist.) SKET….. 9 Nm 5 Nm 50 mm block (single thyrist.) TZ….. 12 Nm 6 Nm 60 mm block TT425/TT570 12 Nm 6 Nm Table 4-1 Nominal mounting torques for thyristor modules VI A 4 - 2 DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Chapter 4 - Exchange of Thyristors for Sizes C1/C2/C2b Thyristor module location for: DCS 501 0100 to 0140 for: DCS 501 0200 to 0520 V14/V11 4 2 1 3 2 4 1 3 2 4 V13/V16 V11/V14 1 3 3 1 V16/V13 4 2 3 1 V12/V15 4 2 3 1 2 4 V12/V15 for: DCS 501 0680 ... 1000 for: DCS 501 0700 1 b d a b d 2 2 c a c V14/V11 V16/V13 V12/V15 1 V11 V14 A K K AK AK A A 1 d b 2 a K c a b d 2 c 1 V12 AK V15 1 b d a b d 2 2 c a c 1 V13 V16 Figure 4-1 Location of thyristor modules in DCS 501/6010100...1000 units Note: This drawing is only for showing the location of the modules, the module size can be different! DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f VI A 4 - 3 Chapter 4 - Exchange of Thyristors for Sizes C1/C2/C2b for: DCS 50x 0025 to 0075 and DCS 502 0100 to 0140 for: DCS 502 0200 to 0520 V11/V24 V14/V21 4 2 V16/V23 3 1 4 2 V12/V25 3 1 4 2 V14/V21 1 3 4 2 2 4 3 1 3 1 V15/V22 V12/V25 1 3 4 2 2 4 3 1 V16/V23 V13/V26 2 4 1 3 2 4 V13/V26 1 3 2 4 V24/V11 c a 2 b d c a 2 1 2 c 1 V25 1 b d b d K V23 K V12 1 b d c c a 1 2 c a b d 2 2 2 b a A d A b A 1 V13 c a 1 V22 V15 c a 1 2 AK c a AK c 2 AK AK 2 2 AK b d AK b a K K V14 K V24 1 d V22/V15 b A a d A c b A d V11 a V26/V13 1 b 2 d for: DCS 502 0680 ... 1000 V21 1 a 3 1 V15/V22 for: DCS 502 0700 d 4 2 2 4 K 1 3 V11/V24 1 3 V21/V14 V23/V16 V25/V12 c 1 V26 V16 Figure 4-2 Location of thyristor modules in DCS 50x/60x-0025...0075 units DCS 502/602-0100...0700 units DCS 502/602-0680...1000 units Note: This drawing is only for showing the location of the modules, the module size can be different! VI A 4 - 4 DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Chapter 4 - Exchange of Thyristors for Sizes C1/C2/C2b POWER INTERFACE BOARD Units with U1 0025 to SDCS-PIN-1x / -2x 0075 ADC T51 S1 V1 Units with 0100 to 0350 ADC W1 1000/1 1500/1 X3:1 S2 T52 S1 1500/1 X4:3 S2 G K P2 S2 P1 600/1 * 1.4 T53 K (S1) 1000/1 1500/1 K T51 S1 X4:1 T53 S1 G L (S2) X3:3 S2 1 Units with 0450 to 0520 ADC * 2330/1 for units with 0700 ADC T51 K (S1) L (S2) T53 S1 P2 S2 P1 600/1 * G K G K 2 V11 V14 G K 3 1.3 G K 4 1.3 G K 1.6 G K G K 5 1.5 V13 V16 G K 6 G G FORWARD 1.5 K G K REVERSE G 1.2 K K V15 V12 1.2 G K K Snubber circuit Snubber circuit G 1.4 G K Snubber circuit G K 1.6 R 57 X22:1 3 O C1 D1 Basic drawing / not all elements are shown Figure 4-3 Basic drawing of DCS 501/601 units with SDCS-PIN-1x/-2x DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f VI A 4 - 5 Chapter 4 - Exchange of Thyristors for Sizes C1/C2/C2b POWER INTERFACE BOARD Units with 0025 to 0075 ADC SDCS-PIN-1x / -2x U1 V1 Units with 0100 to 0350 ADC W1 Units with 0450 to 0520 ADC * 2330/1 for units with 0700 ADC T51 S1 T51 K (S1) 1000/1 1500/1 X3:1 S2 T52 S1 L (S2) T51 S1 P2 S2 P1 600/1 * X3:3 1500/1 X4:1 S2 X4:3 T53 S1 T53 K (S1) 1000/1 1500/1 S2 L (S2) T53 S1 P2 S2 P1 600/1 * G 1 K G G G 2 K 2.4 G K 1.3 G K G 3 K K K 6 K 1.6 G K V14 V21 G 2.6 K 1.5 G K 2.2 G K V13 V16 G 2.3 K 1.2 G K 2.5 G K 2.6 V26 G FORWARD G K 1.5 G K 2.1 V24 2.4 G 5 K V11 1.3 G 4 1.4 K 2.2 2.1 V23 G REVERSE K 1.2 G K V22 V25 1.4 Snubber circuit Snubber circuit G K V12 2.3 G K V15 2.5 G K 1.6 Snubber circuit R 57 X22:1 O 3 Basic drawing / not all elements are shown Figure 4-4 VI A 4 - 6 D1 C1 Basic drawing of DCS 502/602 units with SDCS-PIN-1x/-2x DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f X12: 11,12 Figure 4-5 5 7 15 4 14 16 6 HWCOD3 HWCDD5 UA - UU UV VW UA + NC DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f ACOD2 ACOD1 15 13 1k5 12,14 GNDI 0V + 48 V1 FORWARD 4,2 SR2 10 11 BZP6 8,6 REVERSE 9 BZP5 SR1 5 7 BZP4 +48 V1 4 5 BZP3 820R W80 1k5 W81 HW-coding 3k3 W82 Firing pulse channels 6 3 2 3 1 AC/DC voltage measuring circuits BZP2 NC W10 1 0V Armature current measuring resistances BZP1 X13: 1 2 HWCIN4 8,13 GNDI ANTC 3 9,10 STWA IDC Control board IDCM 5M / 6M X6: X5: 19 17 31 29 3 1 35 33 11 9 27 25 19 17 31 29 3 1 35 33 11 9 27 25 K G K G K G K G K G K G K G K G K G K G K G K G 1.6 2.5 1.4 2.3 1.2 2.1 2.6 1.5 2.4 1.3 2.2 1.1 POWER INTERFACE BOARD SDCS-PIN-20xB 6 x 15 Ω D1 3 1 3 1 3 1 C1 W1 V1 U1 6 x 0.1 µF 6A F103 F102 F101 X22: X4: X3: G K G K G K G K G K G K C1 (+) 1.5 2.2 1.3 2.6 1.1 2.4 R57 V15 V22 V13 V26 V11 V24 S2 S1 P1 N/1 T51 P2 S2 S1 P1 N/1 T53 P2 U1 V1 W1 only in case of 4-Q converters PE 1.2 2.5 1.6 2.3 1.4 2.1 G V12 V25 V16 V23 V14 V21 D1 (-) K G K G K G K G K G K Chapter 4 - Exchange of Thyristors for Sizes C1/C2/C2b Typical armature circuit of DCS 50x/60x with SDCSPIN-20xB VI A 4 - 7 Chapter 4 - Exchange of Thyristors for Sizes C1/C2/C2b Module terminals The next figures show a few examples and terminals of thyristor modules. The terminals of modules are also stamped or marked by a sticker. AK K A K1G1 K2 G2 K AK A K2 G2 K1 G1 SKKT27...SKKT106 Note: This drawing is not valid for the types SKKT.…B… Terminals of half-bridge thyristor modules 3 K5 G4 3 A AK K2 G2 K SKKT132,162 Figure 4-7 A K1 G1 G4 K5 2 K7 G6 1 AK K K1 G1 K7 G6 G2 2 1 K2 Figure 4-6 TT162 Terminals of half-bridge thyristor modules AK K A K1 G1 K2 G2 K A 34 AK AK K K2 G2 A G1 K1 SKKT210, SKKT250, TT250...AK34 Figure 4-8 VI A 4 - 8 Terminals of half-bridge thyristor modules DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Chapter 4 - Exchange of Thyristors for Sizes C1/C2/C2b 2 1 4 5 d a 1 2 b c 2 1 4 5 TZ425 or SKET 400 Figure 4-9 (A) 3 Terminals of single thyristor modules (K) (AK) 2 1 5G 4K 6G 7K 4K 5G 3 2 1 7K 6G TT425, 570 Figure 4-10 Terminals of half bridge thyristor modules DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f VI A 4 - 9 Chapter 4 - Exchange of Thyristors for Sizes C1/C2/C2b VI A 4 - 10 DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Chapter 5 - Exchange of Thyristors for Size A5 Installation of "Disc Type" thyristor in converters size A5 (900...2000 A) Required Tools All DCS 500 and DCS 600 converters sizes A5/C3/C4 are equipped with disk type thyristors. The structure of the "Disc type" semiconductor component is such that it requires a certain compression force to operate. The prevention of overheating of the component essentially depends on a well heat dissipation between the semiconductor and the conducted heat sink. It is thus important that all joints have good thermal and electrical conduction. Special tools or material needed in addition to standard tools for the exchange of thyristor modules: - Torque spanner for electrical connections: 13 Nm (M8) 25 Nm (M10) 50 Nm (M12) - Screws are metric type; use appropriate nuts. - 17 mm ring spanner for fuse and busbar connections. - 17 mm ring spanner for press clamp. - Tissue paper / solvent (e.g. ethanol). - Thermal joint compound: type BECHEM-RHUS SU 2 (grease) Manufacturer: ABB Service: - Disassembly tool Note: Carl Bechem GmbH, 58089 Hagen GHSN 390 001 P 0001 3ADT 621 023 P1 For more detailed information about the wiring of the power part, see manual Technical Data. Therefore strict observance of the build in instructions given below is of utmost importance. Make sure that the new component can replace the old one in accordance with the spare part list (see Appendix A). Semiconductors and heat sinks are to be handled carefully to avoid scratches and other damage. Avoid touching the contact surfaces. Do not lift the semiconductor with the gate wire. Do not lift the semiconductor unit touching the current contact surfaces. Do not damage the welding flange or the contact surface. Before you start work, disconnect the converter completly from the power supply then check the voltage free condition and make sure, everything is located in an electrically and mechanically safe condition! DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f VI A 5 - 1 Chapter 5 - Exchange of Thyristors for Size A5 Find faulty thyristor 1. Find the defective branches by performing an OHM test (both polarities) between U1, V1, W1 and C1, D1 (see figure 5-1) C1 (+) branching fuse U1 V1 W1 branch D1 (-) Figure 5-1 Basic B6-bridge with branching fuses 2. Disconnect the branch fuses of the defective branches. 3. Find the defective thyristors by performing an OHM test (both polarities) over their heat sinks. 4. In a 4-quadrant converter change both thyristors clamped between the same heatsinks at once. Note: Because “Disc Type” semiconductors need a certain compression force to operate properly a measurement outside the clamped heat sinks might be wrong. To be sure change only one thyristor, clamp the heat sinks again and repeat step three. VI A 5 - 2 DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Chapter 5 - Exchange of Thyristors for Size A5 Remove faulty thyris- 1. Remove the screws of the DC – busbars and branch fuses pretor venting the stack to be prized open. Note: It depends on the location of the defective thyristor which DC – busbar and fuses have to be disconnected. 2. Write down the direction and location of the thyristors to be removed and mark their gate leads. 3. Remove the gate leads if possible. 4. Loosen the mounting clamp (see figure 5-3) at the top of the thyristor stack. Attention: While loosen the mounting clamp the indicating spring must be pulled out a little, otherwise the spring will be damaged! 5. Attach the disassembly tool at the faulty thyristor and prize open the upper and lower heat sinks (see figure 5-2). 6. Remove the thyristors. Attention: To centre the thyristors spring pins are used. The pins are inlayed into all lower heat sinks. Open the gap wide enough that the thyristor and the pins are not damaged while removing the thyristor! Mounting clamp View from the right View from the left Disassembly tool Front view Figure 5-2 How to use the disassembly tool DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f VI A 5 - 3 Chapter 5 - Exchange of Thyristors for Size A5 Install new thyristor 1. Ensure that the new thyristor is of the correct type (see Appendix A). Keep the semiconductor and its surroundings clean. If necessary clean them with a piece of tissue paper moistened with solvent. Note: Do not touch the polished surfaces of the thyristor. 2. Clean the polished surfaces of the semiconductor with a piece of tissue paper moistened with solvent. Dry all surfaces. Spread a thin layer of heat conducting paste on both sides of the thyristor, if necessary use a rubber spatula. 3. Connect the gate leads if possible. 4. Clean all parts with tissue paper moistened with solvent, witch have had or will have contact with the thyristor or each other (lower / upper heat sink). Do not clean the surfaces of grease too thoroughly, because the aluminium surfaces will oxidise in a few seconds. Dry all surfaces. 5. Centre the thyristors by means of the spring pins. Note: Be sure that the thyristor is installed in the right direction. Do not pinch or cut the gate leads or any other cable. 6. Turn the thyristor so that the gate leads point in the right direction. Loose condition Insulating plate In- sulating tube TORQUE INDICATING SPRING Heatsink Correct torque Figure 5-3 VI A 5 - 4 Aluminium spring with welded indicating spring DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Chapter 5 - Exchange of Thyristors for Size A5 7. Tighten the nuts of the mounting clamp by hand so that the clamp is in parallel with the contact surface of the heat sinks. Note: The indicating spring is a very sensitive instrument and must be handled with care. 8. Tighten each nut in turn, half a turn at a time with the help of a ring spanner until the indicating spring clicks into position “correct torque” (see figure 5-3). Do not tighten the screws any further. Note: The correct torque is indicated by means of the welded indicating spring. 9. Perform an OHM test to make sure the thyristor is ok. 10. Reconnect the DC – busbars, branch fuses and all other dismantled parts. 11. Perform an OHM test between U1, V1, W1 and C1, D1 to make sure the power part is ok. U1 V1 right stack left stack rear W1 front front rear V24 V11 V14 V21 V13 V26 V23 V16 V22 V15 V12 V25 View from the left Figure 5-4 Front view View from the right Location of thyristors in frame A5 (4-Q bridge) DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f VI A 5 - 5 Chapter 5 - Exchange of Thyristors for Size A5 U1 V1 left stack rear right stack front front rear V11 V14 V13 V16 V15 V12 View from the left Figure 5-5 VI A 5 - 6 W1 Front view View from the right Location of thyristors in frame A5 (2-Q bridge) DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Chapter 5 - Exchange of Thyristors for Size A5 W1 V1 U1 D1 (-) C1 (+) Figure 5-6 Location of branch fuses frame A5 DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f VI A 5 - 7 Chapter 5 - Exchange of Thyristors for Size A5 VI A 5 - 8 DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Chapter 6 - Exchange of Thyristors for Size C3 Installation of "Disc Type" thyristor in converters size C3 (900...2000 A) Required Tools All DCS 500 and DCS 600 converters sizes A5/C3/C4 are equipped with disk type thyristors. The structure of the "disc type" semiconductor component is such that it requires a certain compression force to operate. The prevention of overheating of the component essentially depends on a well heat dissipation between the semiconductor and the conducted heat sink. It is thus important that all joints have good thermal and electrical conduction. Special tools or material needed in addition to standard tools for the exchange of thyristor modules: - Torque spanner: mounting torques and forces for disc type thyristors see Table 6-1 electrical connections: 13 Nm (M8) 25 Nm (M10) 50 Nm (M12) - Screws are metric type; use appropriate nuts. - 13 mm nut for thyristor fixing with 20 mm max outer diameter. - Tissue paper / solvent (e.g. ethanol). - Molikote (MSO2 ). - Thermal joint compound: type BECHEM-RHUS SU 2 (grease) Manufacturer: ABB Service: Note: Carl Bechem GmbH, 58089 Hagen GHSN 390 001 P 0001 For more detailed information about the wiring of the power part, see publication Technical Data. Therefore strict observance of the build in instructions given below is of utmost importance. Different press clamps are used, depending on the size of the semiconductor. Make sure that the new component can replace the old one in accordance with the spare part list (see Appendix A). Before you start work, disconnect the converter completly from the power supply then check the voltage free condition and make sure, everything is located in an electrically and mechanically safe condition! DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f VI A 6 - 1 Chapter 6 - Exchange of Thyristors for Size C3 Remove faulty thyris- - Remove the plastic cover in front of the heat sinks; the screws are accessible, if the SDCS-PIN-x1 boards will be unfastened; tor there is no need to disconnect the electrical connections at the PIN-x1 boards. - Remove the fuse, connected to that thyristor (pair) which needs to be exchanged. - Disconnect the lead of a snubber capacitor connected to the heat sink; if the very right or left plastic cover is fixed at the heat sink, which needs to be removed remove the screw. - If you have a 2 quadrant converter: • Loosen the screws, which keep the press clamp and the heat sink in position; remove the heat sink, mark the direction of the thyristor and the positition of the gate leads, then remove the thyristor. - If you have a 4-quadrant type converter: • Always start working at that thyristor which is part of the reverse bride (V21, V22 a.s.o.) loosen the screws, which keep the press clamp and the heat sink in position; remove the heat sink, mark the direction of the thyristor and the positition of the Gate leads, then remove the thyristor. Find faulty thyristor VI A 6 - 2 - Perform the OHM test with both polarities. Use the DC terminal of the antiparallel thyristors connected as one measuring point and the remaining heat sink as the other. Case a) If this test indicates high resistance, the remaining thyristor is all right healthy and the one already removed should be marked and needs to be replaced. Case b) If this test indicates low resistance, the remaining thyristor is faulty and needs to be replaced. Remove it in the way described above. The other thyristor is ok! - In case a) of the OHM test described above mount a new thyristor at the position of the reverse bridge. - In case b) of the OHM test described above a new thyristor for the forward bridge and afterwards the thyristor of the reverse bridge which was removed first have to be mounted. DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Chapter 6 - Exchange of Thyristors for Size C3 Install new thyristor - Ensure that the new thyristor is of the correct type (see Appendix A). Keep the semiconductor and its surroundings clean. If necessary clean them with a piece of tissue paper moistened with solvent. Make sure the insulator of the thyristor and the connections are fine. Note: Do not touch the polished surfaces of the thyristor. - Clean the polished surfaces of the semiconductor with a piece of tissue paper moistened with solvent. Dry all surfaces. Spread a thin layer of heat conducting paste on both sides of the thyristor, if necessary use a rubber spatula. - Clean all parts with tissue paper moistened with solvent, witch have had or will have contact with the thyristor or each other (bottom of upper heat sink, busbar on both sides and upper side of the DC and AC busbar). Do not clean the surfaces of grease too thoroughly, because the aluminium surfaces will oxidise in a few seconds. Dry all surfaces. - Connect the gate leads if possible. - Place the thyristor with the right direction into the guiding tool. Spread the head conducting paste by turning the thyristor 90° left and right. Note: Do not pinch or cut the gate leads or any other cable. - Turn the thyristor so that the gate leads point in the right direction. Fasten the clamp - Spread a thin layer of Molikote (MSO2) on the thread and under the lower side of the head of each of the srews, keeping the heat sink by means of the press clamp in place. Spread Molikote also on the side of the washers, which comes in contact with the screw. Spread a thin layer of heat conducting paste on the bottom of the heat sink with a rubber spatula. Place the busbar and the heat sink above the thyristor and fix them with the press clamp. Tighten the clamping screws by hand until the screw heads touch the bottom of the module. Molikote DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f VI A 6 - 3 Chapter 6 - Exchange of Thyristors for Size C3 - Find the required torque from the table below. Tighten the screws alternatively 1/4 turn at a time until the correct torque is reached. Converter type Torque / Nm Force / kN Press clamp 400 V - 500 V DCS x0x-0900-4(5) 5,5 - 6 8 - 12 SLZF 89A DCS x0x-1200-4(5) 5,5 - 6 8 - 12 SLZF 89A DCS x0x-1500-4(5) 11,5 - 12 14,4 - 24 SLZF 89B DCS x0x-2000-4(5) 11,5 - 12 14,4 - 24 SLZF 89B 10 - 15 SLZF 89A 14,4 - 24 SLZF 89B 600 V - 690 V DCS x0x-0900-6(7) 7,5 - 8 DCS x0x-1500-6(7) 11,5 - 12 Table 6-1 Mounting torques and forces for disc type thyristors - In case of a 4-quadrant type converter: • Perform the OHM test with both polarities another time to make sure, the thyristor, which was used for the reverse bridge, is definitly healthy. • If this test indicates high resistance, the thyristor is healthy and can be used. • If this test indicates low resistance, the thyristor of the reverse bridge is faulty and needs to be replaced: remove it again mount a new one as described above. - Install in the fuse(s). - Connect the lead of the snubber capacitor, if it was removed before. - Reconnect all parts, which were removed before: • plastic covers, etc. VI A 6 - 4 DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Chapter 6 - Exchange of Thyristors for Size C3 P2 P2 T51 T53 P1 P1 Direction of the thyristors F11 F14 F13 F16 Indicator F15 F12 Connect wiring of snubber circuits !! Front view Figure 6-1 View from the left Location of thyristors in modules size C3 DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f VI A 6 - 5 Chapter 6 - Exchange of Thyristors for Size C3 Thyristors only in the case of 4-Q converters Figure 6-2 VI A 6 - 6 Location of thyristors in modules size C3 Note: Removed fuses, busbars and upper parts of heat sinks DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Chapter 7 - Exchange of Thyristors for Size C4 Installation of "Disc Type" thyristor in converters size C4 (2050...5150 A) Required Tools All DCS 500 and DCS 600 converters sizes A5/C3/C4 are equipped with disk type thyristors. The structure of the "Disc type" semiconductor component is such that it requires a certain compression force to operate. The prevention of overheating of the component essentially depends on a well heat dissipation between the semiconductor and the conducted heat sink. It is thus important that all joints have good thermal and electrical conduction. Special tools or material needed in addition to standard tools for the exchange of thyristor modules: - Torque spanner for electrical connections: 13 Nm (M8) 25 Nm (M10) 50 Nm (M12) - Screws are metric type; use appropriate nuts. - 17 mm ring spanner for fuse and busbar connections. - 24 mm ring spanner for press clamp. - Tissue paper / solvent (e.g. ethanol). - Thermal joint compound: type BECHEM-RHUS SU 2 (grease) Manufacturer: ABB Service: - Disassembly tool: Note: Carl Bechem GmbH, 58089 Hagen GHSN 390 001 P 0001 DCF 1066721 P1 For more detailed information about the wiring of the power part, see publication Technical Data. Therefore strict observance of the build in instructions given below is of utmost importance. Make sure that the new component can replace the old one in accordance with the spare part list (see Appendix A). Thyristors are always mounted in the same direction, independent of current, voltage, number of quadrants (2-Q or 4-Q) version or left or right side connection. Semiconductors and heat sinks are to be handled carefully to avoid scratches and other damage. Avoid touching the contact surfaces. Do not lift the semiconductor with the gate wire. Do not lift the semiconductor unit by touching the current contact surfaces. Do not damage the welding flange or the contact surface. Before you start work, disconnect the converter completly from the power supply then check the voltage free condition and make sure, everything is located in an electrically and mechanically safe condition! DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f VI A 7 - 1 Chapter 7 - Exchange of Thyristors for Size C4 Find faulty thyristor - Find the defective branch(es) by performing an OHM test (both polarities) between U1, V1, W1 and C1, D1 (see Figure 5-1). - Remove the screws of the left and right branch fuses. Remove the busbar, leading to the AC connection, too (not necessary at 2-quadrant converters, left version!). - If you have a 4-quadrant converter: • Remove the screws of the DC busbar either above or below the blown fuse. Note: the connection is made with a screw socket, which may fall down, if the last screw is removed. • Put a small piece of isolator (paper, cardboard, plastic, etc.) between the DC busbar and the heat sink. • Perform the OHM test with both polarities between the DC busbar and the heat sink as the second measuring point. • Now perform the OHM test with both polarities between the isolated heat sink and the heat sink, which was connected to the fuse as the second measurement point. • Depending on the result, the thyristor located between the measuring terminals of the first test or the second one needs to be removed. Remove faulty thyris- - If the thyristor is partly covered by a fuse, loosen the screws and tor move the fuse some centimeters up or down; fix the fuse. - Remove the gate leads if possible. - Loosen the mounting clamp (see Figure 7-2) at the top of the thyristor stack. Attention: While loosen the mounting clamp the indicating spring must be pulled out a little, otherwise the spring will be damaged! - Attach the disassembly tool at the faulty thyristor and prise open the upper and lower heat sinks (see Figure 7-1). The copper bars need not be loosened . - Remove the thyristor. VI A 7 - 2 DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Chapter 7 - Exchange of Thyristors for Size C4 Mounting clamp View from the right View from the left Disassembly tool Front view Figure 7-1 Install new thyristor How to use the disassembly tool (at a left thyristor stack of a converter) - Ensure that the new thyristor is of the correct type (see Appendix A). Keep the semiconductor and its surroundings clean. If necessary clean them with a piece of tissue paper moistened with solvent. Note: Do not touch the polished surfaces of the thyristor. - Clean the polished surfaces of the semiconductor with a piece of tissue paper moistened with solvent. Dry all surfaces. Spread a thin layer of heat conducting paste on both sides of the thyristor, if necessary use a rubber spatula. - Connect the gate leads if possible. - Clean all parts with tissue paper moistened with solvent, witch have had or will have contact with the thyristor or each other (lower / upper heat sink). Do not clean the surfaces of grease too thoroughly, because the aluminium surfaces will oxidise in a few seconds. Dry all surfaces. - Push the thyristor until it snaps into its mounting clamp. Note: Be sure that the thyristor is installed in the right direction. Do not pinch or cut the gate leads or any other cable. - Turn the thyristor so that the gate leads point in the right direction. DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f VI A 7 - 3 Chapter 7 - Exchange of Thyristors for Size C4 Loose condition Insulating plate In- sulating tube TORQUE INDICATING SPRING Heatsink Correct torque Figure 7-2 Aluminium spring with welded indicating spring - Tighten the nuts of the mounting clamp by hand so that the clamp is in parallel with the contact surface of the heat sinks. Note: The indicating spring is a very sensitive instrument and must be handled with care. - Tighten each nut in turn, half a turn at a time with the help of a ring spanner until the indicating spring clicks into position “correct torque” (see Figure 7-2). Do not tighten the screws any further. Note: The correct torque is indicated by means of the welded indicating spring. - Perform an OHM test to make sure the thyristor is ok. - Reconnect the DC / AC – busbars, branch fuses and all other dismantled parts. - Perform an OHM test between U1, V1, W1 and C1, D1 to make sure the power part is ok. VI A 7 - 4 DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Chapter 7 - Exchange of Thyristors for Size C4 V11 V21 V21 V11 V24 V14 V14 V 24 V13 V 23 V23 V 13 V26 V16 V16 V26 V15 V25 V25 V15 V22 V12 V12 V22 Assemb ly C4 Busba rs o n th e ri ght (fr ont o f the module) Figure 7-3 A ssembly C4 B usbars on the left ( front of th e mod ule ) Location of thyristors in size C4 (4-Q bridge) V11 V11 V14 V 14 V 13 V13 V16 V 16 V15 V15 V12 V12 A ssemb ly C4 B usba rs o n th e right ( front o f the module ) Figure 7-4 Assemb ly C4 Busba rs o n th e left (fr ont o f th e mod ule ) Location of thyristors in frame C4 (2-Q bridge) DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f VI A 7 - 5 Chapter 7 - Exchange of Thyristors for Size C4 VI A 7 - 6 DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Chapter 8 - Compatibility of SDCS-PIN-2 boards Description of SDCSPIN-20xB boards - In general the SDCS-PIN-20xB board has the same features as its predecessors (SDCS-PIN-20xA/20x or SDCS-PIN-2x). - It is used for all DCS converters Module sizes C1 (≥ 100A), C2 and C2b regardless of software version and function (armature or field supply). - Converters equipped with the SDCS-PIN-20xB/20xA/20x boards can be identified by serial number. Every serial number is divided into two parts by a letter. With the SDCS-PIN20xB/20xA/20x the serial number looks like 1234567B1234567. For the SDCS-PIN-2x an A is used. - There are two types of SDCS-PIN-20xB boards: • SDCS-PIN-205B for converters with a incoming voltage of 400V/500V • SDCS-PIN-206B for converters with a incoming voltage of 600V - The advantage of the SDCS-PIN-20xB/20xA/20x is the replacement of 6 other boards plus a small RC network. Thus the spare part handling becomes easier. Hardware coding On the SDCS-PIN-20xB resistors are used for hardware coding of the module, zero current detection and current scaling. In a new converter the resistors are already cut according to application. If the SDCS-PIN-20xB board is used as spare part all resistors are still uncut. The resistors have to be cut according to the table ‘Settings of the SDCS-PIN-20xB board’ as described in the manual Technical Data. Snubber circuit The incoming AC voltage is connected to the SDCS-PIN-20xB board via integrated fuses. The snubber circuit (RC network) is integrated as well and connected in parallel to the thyristors. This configuration leads to lower losses thus to a higher efficiency of the converter. Before larger converters had external RC networks. These are no longer needed. DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f VI A 8 - 1 Chapter 8 - Compatibility of SDCS-PIN-2 boards Compatibility of SDCS-PIN-20x boards The SDCS-PIN-20xB boards replaces SDCS-PIN-20xA and SDCSPIN-20x boards, but not vice versa. Note: SDCS-PIN-20xA replaces SDCS-PIN-20x, but not vice versa. UAC 400V/500V 600V IDC 100A-350A 405A-520A 700A 610A-1000A 100A-270A 405A/450A Type C1/C2 C2 C2 C2b C1/C2 C2 9 9 9 9 SDCS-PIN-205B 9 9 SDCS-PIN-206B 9 SDCS-PIN-21 9j SDCS-PIN-22 9 SDCS-PIN-23 9j SDCS-PIN-24 9k SDCS-PIN-25 9 9 9 SDCS-PIN-205A/205 9 9 SDCS-PIN-206A/206 9: possible - : not possible j together with SDCS-PIR-21 k together with RC network Table 8-1 Compatibility of SDCS-PIN-2xx boards Compatibility of SDCS-PIN-20x and SDCS-PIN-2x boards Converters 100A ≤ IDC ≤ 350A and UAC: 400V/500V - SDCS-PIN-21 or - SDCS-PIN-205B/205A/205 can be used as spare parts. Converters 405A ≤ IDC ≤ 520A and UAC: 400V/500V - SDCS-PIN-22 together with SDCS-PIR-21 or - SDCS-PIN-205B/205A/205 can be used as spare parts. Converters IDC = 700A and UAC: 400V/500V (type C2) - SDCS-PIN-25 together with RC network (possible only in converters with an A in their serial number) or - SDCS-PIN-205B/205A/205 can be used as spare parts (possible in converters with an A or B in their serial number). In an A converter do not connect the RC network. Note: In a B converter only SDCS-PIN205B/205A/205 boards are usable, because the RC network is missing. Converters 610A ≤ IDC ≤ 1000A and UAC: 400V/500V (type C2b) only - SDCS-PIN-205B can be used as spare part. Converters 100A ≤ IDC ≤ 270A and UAC: 600V - SDCS-PIN-23 - SDCS-PIN-206B/206A/206 can be used as spare parts. Converters IDC = 405A/450A and UAC: 600V - SDCS-PIN-24 together with SDCS-PIR-21 or - SDCS-PIN-206B/206A/206 can be used as spare parts. Note: In addition to above mentioned limitations make sure that the resistors are cut properly according to the table ‘Settings of the SDCS-PIN-20xB board’ as described in the manual Technical Data. Especially when a board is reused! VI A 8 - 2 DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Chapter 8 - Compatibility of SDCS-PIN-2 boards Change SDCS-PIN-2x boards The converter is equipped with a SDCD-PIN-21/22/23/24 board: - Make sure, electrical and mechanical safety is obtained! - Mark the cables connected to U1, V1, W1 and C1, D1. Mark the plugs connected to X22, X3 and X4. - Disconnect all cables and plugs. - Remove the SDCS-PIN-2x board. Note: If the converter is equipped with a SDCS-PIR-21 there is no need to remove this board separately, because it is mounted on the SDCS-PIN-2x board. - Make sure that the resistors on the new board are cut properly according to the table ‘Settings of the SDCS-PIN-20xB board’ as described in the manual Technical Data. - Install the new SDCS-PIN-20xB board. Note: SDCS-PIN-205B replaces SDCS-PIN21/23 and SDCSPIN-206B replaces SDCS-PIN-22/24. - Reconnect all cables and plugs. The converter is equipped with a SDCD-PIN-25 board: - Make sure, electrical and mechanical safety is obtained! - Mark the cables connected to U1, V1, W1 and C1, D1. Mark the plugs connected to X22, X3 and X4. - Disconnect all cables and plugs. - Remove the SDCS-PIN-25 board. Note: The additional RC network is not needed anymore. Due to safety reasons remove the cables marked U1 – C14, V1 – C16, W1 – C12, C1 – R15 and D1 – R12. - Make sure that the resistors on the new board are cut properly according to the table ‘Settings of the SDCS-PIN-205B board’ as described in the manual Technical Data. - Install the new SDCS-PIN-205B board. Note: SDCS-PIN-205B replaces SDCS-PIN25. - Reconnect all cables and plugs. DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f VI A 8 - 3 Chapter 8 - Compatibility of SDCS-PIN-2 boards VI A 8 - 4 DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Chapter 9 - Preventive Maintainance WARNING! Before performing any maintenance the chapter ‘Safety Instructions’ at the beginning of this manual and within the corresponding Operating Instructions must be followed. Negligence of these instructions can cause injury or death. Recommended regular maintenance The DCS requires very little maintenance if installed in an appropriate environment. An annual check for dust accumulation and corrosion inside the module / cabinet is recommended. Air Filters When air filters are used, the filters should be checked regularly depending on environmental conditions. Clocked up filters prevent the proper cooling of the drive. Wash dirty filters with water (60°C) and detergent. Cooling air pressure switch in converter modules type C4 The cooling air pressure switch must be checked regularly. The following actions have to take place: - Make sure electrical safety is performed. - Open the module's door and hold it in position to prevent any movement. - Repeat it with the cabinet’s door. - Switch on the drive and try to turn the motor. - The air pressure switch is ok when the converter is switched off by error “F50 NO C FAN”; crosscheck this result with the module’s door closed. Fan The lifetime of the cooling fan is about 20.000 to 40.000 hours depending on the converter type. The actual lifetime depends on the usage of the DCS and the ambient temperature. Fan failure can be predicted by means of increasing noise from its bearings and a gradual rise of the heatsink temperature. If the DCS operates in a critical part of the process it is recommended to replace the fan once the above mentioned symptoms appear. Heatsink The DCS will run into overtemperature faults if the heatsinks are not clean. In an appropriate environment the heatsinks should be checked and cleaned annually. Use compressed air to remove the dust from the heatsinks (the air flow must be from bottom to top). Fan rotation caused by the compressed air must be stopped in order to prevent damage. Additionally use a vacuum cleaner to clean the dust from the air inlet and outlet. DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f VI A 9 - 1 Chapter 9 - Preventive Maintainance Internal high current connections in converters type C4 The thyristors together with the heatsinks are stacked. Every single thyristor is connected to the DC+ and DC- busbars via flexible copper busbars. These busbars consist of 10 layers of preshaped sheet copper. This construction is able to compensate for small changes in length caused by temperature rise when current is flowing. The screw fixings between heatsink and flexible copper busbar have to withstand different types of mechanical stress. Therefore each fixing needs to be checked for correct torque. This check should be done regularly, e.g. annually or together with all the other work to be done for preventive maintenance. Actions: - Make sure all supply voltages are switched off, most important the supply for the power part (armature), for the electronic power part (SDCS-POW-1), for the converter fan and for other auxiliaries! - Open the cabinet’s and module’s door; if needed secure them. - Set a latching torque spanner to 25 Nm (18 lb-ft); a 17 mm nut is needed too. - Check the torque of the screws marked within Figure 9-1 at the end of this chapter: - Apply the torque spanner to the screw and turn right until the right torque is indicated. - Don’t loosen the screws by a left hand turn! - Put on a new marking, if appropriate. Relays and electrical connections Relays should be checked for proper function and all connections should be inspected and checked for tightness. Any signs of corrosion, especially at ground components, must be removed. VI A 9 - 2 DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Chapter 9 - Exchange of Thyristors 25 - 700 A Screws to be checked: Screws to be checked: Screws to be checked: Screws to be checked (located behind the busbar): Figure 9-1: Power part of a converter module type C4 DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f VI A 9 - 3 Chapter 9 - Preventive Maintainance VI A 9 - 4 DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Appendix A - Spare Parts List Item 2.10 to Item 3.60 Common Electronic Parts 2.10 COMMON PARTS FOR CONV. DCS500B/DCF500Bxxxx-xx-21..(CON-2) DESCRIPTION QTY CODE TYPE/DATA NOTES Control board DCS500 B 1 3ADT220072R4 SDCS-CON - 2 Power supply board 1 3ADT220090R3 SDCS-POW-1 COAT with actual software21.xxx 2.20 COMMON PARTS FOR CONV. DCS600 / DCF600xxxx-xx-15.MultiDrive; 18.Crane SW DESCRIPTION QTY CODE TYPE/DATA NOTES Control board +AMC-DC Board 1* 3ADT220072R5 SDCS-CON-2+AMC-DC w.act. SW.15.xxx+AMC-DC-Board. Control board +AMC-C-Clas1. 1* 3ADT220072R7 Control b.+AMC-DC Crane 1* 3ADT220072R22 CON-2-18+AMC DC Control b.+AMC-C-Clas1/Crane 1* 3ADT220072R20 CON-2-18+AMC-C Power supply board 1 3ADT220090R3 SDCS-POW-1 COAT SDCS-CON-2+AMC-C w.act.SW.15.xxx+AMC-C-Board. Crane SW18+AMC-DC; incl.Fee Crane SW18+AMC-C;incl.Fee *) Select only one Board 2.30 Interface Boards; Panels for DCS500B/DCS600 Modules / Cabinets DESCRIPTION QTY CODE TYPE/DATA NOTES *)DI/DO connection board 1* 3BSE005176R1 SDCS-IOB-21 24V DC-48V DC *)DI/DO connection board 1* 3BSE005177R1 SDCS-IOB-22 115V AC *)DI/DO connection board 1* 3BSE005178R1 SDCS-IOB-23 230V AC AI/AO connection board 1 3BSE004086R1 SDCS-IOB-3 Communication Board/DCS500B 1 3ADT220059R1 SCDS-COM-5 separate; only for DCS500B AMC-Communic. Board DCS600 1 3ADT309900R1 AMC-DC Board without Software f. DCS600 AMC-Communic. Board DCS600 1 3BSE017192R1 Control Panel 1 3ADT220071R5 CDP312 Rev.F I/O Extension Board 1 3BSE005851R1 SDCS-IOE-1 Adapt. Board /Analog Tacho 1 3ADT300600R1 PS 5311- SET AMC-DC_Clas1-Board without Software f. DCS600 For DCS500B & DCS600 *) Select only one Board DCR-Kit contains: 2Q 4Q 2.40 PARTS FOR DCR REBUILD KITS, 12 PULSE AND PARALLELING DCS CONV. 2Q 4Q CODE TYPE/DATA DESCRIPTION Cooling fan 1 1 DCA0017670P1 CN52B2 Pulse Interface Board 1 1 DCF1154914R1 SDCS-REB-1 DCR for DCR500B/600 Type Pulse Amplifier Board 1 1 DCF1192115R1 SDCS-REB-2 DCR Pulse Distribution Board 1 1 3ADT309300R1 SDCS-REB-3 DCR Power Supply for REB-2 2 2 DCE8920037P1 NPSM-01 230V//24V DC// 2A DCR SDCS- PIN- 41A and PIN-51 see item 19.00 - 38.00 or below Pulstransformer Board 1 2 3BSE004939R1 SDCS-PIN-41 A Power interface board 1 1 3BSE004940R1 SDCS-PIN-51 Current Measurement Aid 1 1 3ADT220090R22 SDCS-CMA-2-Coat Paralleling Interface Board 1 1 1 3ADT311200R1 SDCS-PAR-1 Paralleling Master Conv. Paralleling Interface Board 2 1 1 3ADT311300R1 SDCS-PAR-2 Paralleling Slave Conv. DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f for 400V up to 1000V AC 12 Pulse and Paralleling Converter VI A A - 1 Appendix A- Spare Parts List 2.50 2-PHASE FIELD EXCITERS DESCRIPTION QTY CODE TYPE/DATA Integrated uncontr. 6 A; FEX-1 1 DCA0012317R1 SDCS-FEX-1 Integrated single 16 A; FEX-2 1 DCA0012325R1 SDCS-FEX-2 A Sep. compl. Unit; incl. Thyristor M. Control Board DCF503A0050 1 3ADT312400R2 SDCS-FEX-32A Control Board f. DCF503A0050 Thyristor/Diode Module 1Q 50A 2 DCA0003270P1 SKKH 57/16 E Control Board DCF504A0050 1 3ADT312400R1 SDCS-FEX-31A Thyristor modules 4Q 50A 2 DCA0011132P1 SKKT42/16E Ext. DCF503A0050; 1Q 50 A 1 3ADT209019R1 DCF503A0050 Complete unit DCF503A0050 Ext. DCF504A0050; 4Q 50 A 1 3ADT209019R2 DCF504A0050 Complete unit DCF504A0050 3.10 Coated Boards for DCS500B see item 2.10 DESCRIPTION QTY CODE NOTES Sep. compl. Unit; incl. Diode M. for DCF503-0050 Control Board f.DCF504A0050 for DCF504-0050 TYPE/DATA NOTES Control board DCS500 B 1 3ADT220072R12 SDCS-CON - 2-21-coat with actual software21.xxx Power supply board 1 3ADT220090R3 3.20 SDCS-POW-1 COAT Repl. for DCA0012279R0001 Coated Boards for DCS600 / DCF600 see item 2.20 Control board +AMC-DC Board 1* 3ADT220072R9 Control board +AMC-C-Clas1. 1* 3ADT220072R11 CON-2+AMC-C-coat Power supply board 1 3ADT220090R3 SDCS-POW-1 COAT Repl. for DCA0012279R0001 3.30 CON-2+AMC-DC-coat w.act. SW.15.xxx+AMC-DC-Board. w.act.SW.15.xxx+AMC-C-Board. Coated Interface Boards; Panels for DCS500B / DCS600 Modules / Cabinets *)DI/DO connection board 1* 3ADT220090R14 SDCS-IOB-21-coat 24V DC-48V DC *)DI/DO connection board 1* 3ADT220090R13 SDCS-IOB-22-coat 115V AC *)DI/DO connection board 1* 3ADT220090R23 SDCS-IOB-23-coat 230V AC AI/AO connection board 1 3ADT220090R20 SDCS-IOB-3-coat Communication Board 1 3ADT220090R26 SCDS-COM-5-coat I/O Extension Board 1 3ADT220090R25 SDCS-IOE-1-coat Adapt. Board /Analog Tacho 1 3ADT220090R29 PS 5311- coat 3.40 separate Coated Boards for DCR Rebuild Kits and 12 PULSE-Systems See item 2.30 Pulse Interface Board 1 1 3ADT220090R9 SDCS-REB-1-coat Coated Board for DCR Coated Board for DCR Pulse Amplifier Board 1 1 3ADT220090R34 SDCS-REB-2-coat Pulstransformer Board 1 2 3ADT220090R5 SDCS-PIN-41 A-coat Power interface board 1 1 3ADT220090R6 SDCS-PIN-51-coat for 400V up to 1000V AC Current Measurement Aid 1 1 3ADT220090R22 SDCS-CMA-2-coat 12 Pulse and Paralleling Converter 3.50 Coated Boards for 2-PHASE FIELD EXCITERS see item 2.50 Integrated single 16 A; FEX-2 1 3ADT220090R19 SDCS-FEX-2 A-coat Control Board DCF503A0050 1 3ADT220090R37 SDCS-FEX-32A-coat Coat. Contr. Board DCF503A.. Sep. compl. Unit; coated Vers. Control Board DCF504A0050 1 3ADT220090R36 SDCS-FEX-31A-coat Coat. Contr. Board DCF504A.. Ext. DCF503A-0050; 1Q 50 A 1 3ADT209019R0101 DCF503A0050-Coat Complete unit DCF503A0050 Ext. DCF504A0050; 4Q 50 A 1 3ADT209019R0102 DCF504A0050-Coat Complete unit DCF504A0050 VI A A - 2 DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Appendix A - Spare Parts List 3.60 Coated Boards for 25A - 5150A Modules Power interface board 1 1 3ADT220090R27 Power interface board 1 1 3ADT220090R35 SDCS-PIN 205B-Coat 100A - 1000A/400/500V Mod. SDCS-PIN-11-coat Power interface board 1 1 3ADT220090R38 SDCS-PIN 206B-Coat 110A,270A and 450A/600V M. Power interface board 1 1 3ADT220090R6 Puls transformer board 1 2 3ADT220090R5 SDCS-PIN-51-coat 25A; 50A and 75A Mod. for 400V up to 1000V AC SDCS-PIN-41 A-coat 900A - 5150A *) Select only one Board DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f VI A A - 3 Appendix A- Spare Parts List Item 4.00 to 10.00 Modules DCS500B / DCS600 Size C1 25A----140A 4.00 Common Parts for C1, C2, C2b and C3 Modules DESCRIPTION 2Q 4Q CODE TYPE/DATA Temperature Sensor (R57) 1 1 DCA0012139P1 KTY 10-6 M4 NOTES (C1-C3 / 550mm cable) Fuse F101; F102 and F103 on PIN205B and PIN206B see Modules from 100A to 1000A; item 8.00 - 18.00 Module contains: 2Q 4Q 4.10 25 A (400V-500V) CONVERTER DESCRIPTION 2Q 4Q CODE TYPE/DATA Thyristor modules 3 6 DCA0008018P1 SKKT27/16E * Power interface board 1 1 3ADT306100R1 SDCS-PIN-11 Semiconductor fuses 3 3 DCZ9838767P1 170M1564 Cooling fan 1 1 DCA0017670P1 CN52B2 DCF501,502B, DCF 601, 602 (1) (1) If used as a spare part for DCF... the resistors R113/R116/R119 must be removed. For further information see "Technical Data" * DCS500/DCS600 Thyr. Modules SKKT 27 / 16E are not identical to Thyr. Modules SKKT 27 B/16E used for DCS400 Converter Modules Module contains: 2Q 4Q 5.00 50 A (400V-500V) CONVERTER DESCRIPTION 2Q 4Q CODE TYPE/DATA Thyristor modules 3 6 DCA0011132P1 SKKT42/16E * Power interface board 1 1 3ADT306100R1 SDCS-PIN-11 Semiconductor fuses 3 3 DCZ9838791P1 170M1566 Cooling fan 1 1 DCA0017670P1 CN52B2 NOTES DCF501,502B, DCF 601, 602 (1) (1) If used as a spare part for DCF... the resistors R113/R116/R119 must be removed. For further information see "Technical Data" * DCS500/DCS600 Thyr. Modules SKKT 42 / 16E are not identical to Thyr. Modules SKKT 42 B/16E used for DCS400 Converter Modules Module contains: 2Q 4Q 6.00 50 A (600V) CONVERTER DESCRIPTION 2Q 4Q CODE TYPE/DATA Thyristor modules 3 6 DCA0011906P1 SKKT57/20E * Power interface board 1 1 3BSE005716R1 SDCS-PIN-12 Semiconductor fuses 3 3 DCZ9838791P1 170M1566 Cooling fan 1 1 DCA0017670P1 CN52B2 NOTES changed Oct.2001 * DCS500/DCS600 Thyr. Modules SKKT 57 / 16E are not identical to Thyr. Modules SKKT 57 B/16E used for DCS400 Converter Modules Module contains: 2Q 4Q 7.00 75 A (400V-500V) CONVERTER DESCRIPTION 2Q 4Q CODE TYPE/DATA Thyristor modules 3 6 DCA0011914P1 SKKT57/16E * Power interface board 1 1 3ADT306100R1 SDCS-PIN-11 Semiconductor fuses 3 3 DCA0012686P1 170M1568 Cooling fan 1 1 DCA0017670P1 CN52B2 NOTES DCF501,502B, DCF 601, 602 (1) (1) If used as a spare part for DCF... the resistors R113/R116/R119 must be removed. For further information see "Technical Data" * DCS500/DCS600 Thyr. Modules SKKT 57 / 16E are not identical to Thyr. Modules SKKT 57 B/16E used for DCS400 Converter Modules VI A A - 4 DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Appendix A - Spare Parts List Module contains: 2Q 4Q 8.00 100 A (400V-500V) CONVERTER DESCRIPTION 2Q 4Q CODE TYPE/DATA NOTES Thyristor modules 3 6 DCA0011931P1 SKKT 106/16E * Power interface board 1 1 3ADT312500R1 SDCS-PIN 205B Repl. SDCS PIN-21 and PIN205 Fuse F101- F103 on PIN205B 3 3 3BSC770010R0101 KTK-R6A/660V for PIN205B; min.QTY 10pcs Semiconductor fuses 3 3 DCA0012694P1 170M3815 Cooling fan 1 1 DCA0012678P1 W2E143-AA09-25 * DCS500/DCS600 Thyr. Modules SKKT 106 / 16E are not identical to Thyr. Modules SKKT 106 B/16E used for DCS400 Converter Modules Module contains: 2Q 4Q 9.00 110 A (600V) CONVERTER DESCRIPTION 2Q 4Q CODE TYPE/DATA NOTES Thyristor modules 3 6 DCA0011922P1 SKKT72/20E Power interface board 1 1 3ADT312500R2 SDCS-PIN 206B Repl. SDCS PIN-23 and PIN206 Fuse F101- F103 on PIN206B 3 3 3BSC770010R0101 KTK-R6A/660V for PIN206B; min.QTY 10pcs Semiconductor fuses 3 3 DCA0012694P1 170M3815 Cooling fan 1 1 DCA0012678P1 W2E143-AA09-25 Module contains: 2Q 4Q 10.00 140 A (400V-500V) CONVERTER DESCRIPTION 2Q 4Q CODE Thyristor modules 3 6 TYPE/DATA DCA0011931P1 SKKT 106/16E * NOTES Power interface board 1 1 3ADT312500R1 SDCS-PIN 205B Repl. SDCS PIN-21 and PIN205 Fuse F101- F103 on PIN205B 3 3 3BSC770010R0101 KTK-R6A/660V for PIN205B; min.QTY 10pcs Semiconductor fuses 3 3 DCA0012694P1 170M3815 Cooling fan 1 1 DCA0012678P1 W2E143-AA09-25 * DCS500/DCS600 Thyr. Modules SKKT 106 / 16E are not identical to Thyr. Modules SKKT 106 B/16E used for DCS400 Converter Modules DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f VI A A - 5 Appendix A- Spare Parts List Item 11.00 to 17.10 Modules DCS500B / DCS600 Size C2 200A----520A Module contains: 2Q 4Q 11.00 200 A (400V-500V) CONVERTER DESCRIPTION 2Q 4Q CODE TYPE/DATA NOTES Thyristor modules 3 6 DCA0011931P1 SKKT 106/16E * Power interface board 1 1 3ADT312500R1 SDCS-PIN 205B Repl. SDCS PIN-21 and PIN205 Fuse F101- F103 on PIN205B 3 3 3BSC770010R0101 KTK-R6A/660V for PIN205B; min.QTY 10pcs Semiconductor fuses 3 3 3ADC770024P9 170M3816 Cooling fan 1 1 DCA0012171P1 W2E200-HH38-06 * DCS500/DCS600 Thyr. Modules SKKT 106 / 16E are not identical to Thyr. Modules SKKT 106 B/16E used for DCS400 Converter Modules Module contains: 2Q 4Q 12.00 250 A (400V-500V) CONVERTER DESCRIPTION 2Q 4Q CODE Thyristor modules 3 6 TYPE/DATA DCA0011931P1 SKKT 106/16E * NOTES Power interface board 1 1 3ADT312500R1 SDCS-PIN 205B Repl. SDCS PIN-21 and PIN205 Fuse F101- F103 on PIN205B 3 3 3BSC770010R0101 KTK-R6A/660V for PIN205B; min.QTY 10pcs Semiconductor fuses 3 3 3ADC770024P10 170M3817 Cooling fan 1 1 DCA0012171P1 W2E200-HH38-06 * DCS500/DCS600 Thyr. Modules SKKT 106 / 16E are not identical to Thyr. Modules SKKT 106 B/16E used for DCS400 Converter Modules Module contains: 2Q 4Q 13.00 270 A (600V) CONVERTER DESCRIPTION 2Q 4Q Thyristor modules 3 6 CODE TYPE/DATA DCA0011957P1 SKKT132/20E NOTES Power interface board 1 1 3ADT312500R2 SDCS-PIN 206B Repl. SDCS PIN-23 and PIN206 Fuse F101- F103 on PIN206B 3 3 3BSC770010R0101 KTK-R6A/660V for PIN206B; min.QTY 10pcs Semiconductor fuses 3 3 DCA0003547P1 170M3819 Cooling fan 1 1 DCA0012171P1 W2E200-HH38-06 Module contains: 2Q 4Q 14.00 350 A (400V-500V) CONVERTER DESCRIPTION 2Q 4Q CODE Thyristor modules 3 6 changed in Oct.2001 TYPE/DATA NOTES DCA0011965P1 SKKT 162 / 16E alt.TT162N16KOF - GHSN610178P2 Power interface board 1 1 3ADT312500R1 SDCS-PIN 205B Repl. SDCS PIN-21 and PIN205 Fuse F101- F103 on PIN205B 3 3 3BSC770010R0101 KTK-R6A/660V for PIN205B; min.QTY 10pcs Semiconductor fuses 3 3 DCA0012708P1 170M5810 Cooling fan 1 1 DCA0012171P1 W2E200-HH38-06 Module contains: 2Q 4Q 15.00 450 A (400V-500V) CONVERTER DESCRIPTION 2Q 4Q CODE Thyristor modules 3 6 TYPE/DATA DCA0011973P1 SKKT250/16E NOTES alt.TT250N16KOF-GHSN610089P2 Power interface board 1 1 3ADT312500R1 SDCS-PIN 205B Repl. SDCS PIN-21 and PIN205 Fuse F101- F103 on PIN205B 3 3 3BSC770010R0101 KTK-R6A/660V for PIN205B; min.QTY 10pcs Semiconductor fuses 3 3 DCA0012716P1 170M6811 Cooling fan 1 1 DCA0012171P1 W2E200-HH38-06 VI A A - 6 DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Appendix A - Spare Parts List Module contains: 2Q 4Q 16.00 450 A (600V) CONVERTER DESCRIPTION 2Q 4Q CODE TYPE/DATA NOTES Thyristor modules 3 6 DCA0011981P1 SKKT210/20E Power interface board 1 1 3ADT312500R2 SDCS-PIN 206B Repl. SDCS PIN-23 and PIN206 Fuse F101- F103 on PIN206B 3 3 3BSC770010R0101 KTK-R6A/660V for PIN206B; min.QTY 10pcs Semiconductor fuses 3 3 DCA0012716P1 170M6811 Cooling fan 1 1 DCA0012171P1 W2E200-HH38-06 Module contains: 2Q 4Q 17.00 520 A (400V-500V) CONVERTER DESCRIPTION 2Q 4Q CODE TYPE/DATA alt.TT250N18KOF NOTES Thyristor modules 3 6 DCA0011973P1 SKKT250/16E Power interface board 1 1 3ADT312500R1 SDCS-PIN 205B Repl. SDCS PIN-21 and PIN205 Fuse F101- F103 on PIN205B 3 3 3BSC770010R0101 KTK-R6A/660V for PIN205B; min.QTY 10pcs Semiconductor fuses 3 3 DCA0012716P1 170M6811 Cooling fan 1 1 DCA0012171P1 W2E200-HH38-06 Module contains: 2Q 4Q 17.10 700 A (400V-500V) CONVERTER DESCRIPTION 2Q 4Q CODE Thyristor 6 12 TYPE/DATA alt.TT250N16KOF-GHSN610089P2 NOTES 3ADC340041P1 TZ425N16KOF SKET400/16E - DCA 0011990P1 Power interface board 1 1 3ADT312500R1 SDCS-PIN 205B Repl. SDCS PIN-21 and PIN205 Fuse F101- F103 on PIN205B 3 3 3BSC770010R0101 KTK-R6A/660V for PIN205B; min.QTY 10pcs Semiconductor fuses 3 3 DCA0012724P1 170M6813 Cooling fan 1 1 DCA0012171P1 W2E200-HH38-06 DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f VI A A - 7 Appendix A- Spare Parts List Item 18.10 to 18.30 Modules DCS500B / DCS600 Size C2b 680A----1000A Module contains: 2Q 4Q 18.10 680 A (400V-500V) CONVERTER DESCRIPTION 2Q 4Q CODE TYPE/DATA NOTES Thyristor modules 3 6 3ADC340032P1 TT 425 N16KOF Power interface board 1 1 3ADT312500R1 SDCS-PIN 205B Repl. SDCS PIN-21 and PIN205 Fuse F101- F103 on PIN205B 3 3 3BSC770010R0101 KTK-R6A/660V for PIN205B; min.QTY 10pcs Semiconductor fuses 3 3 DCA0012724P1 170M6813 Cooling fan 1 1 DCA0012171P1 W2E200-HH38-06 Module contains: 2Q 4Q 18.20 820 A (400V-500V) CONVERTER DESCRIPTION 2Q 4Q CODE Fuses also used for Encl. Conv. TYPE/DATA NOTES Thyristor modules 3 6 3ADC340066P1 TT 570 N16KOF Power interface board 1 1 3ADT312500R1 SDCS-PIN 205B Repl. SDCS PIN-21 and PIN205 Fuse F101- F103 on PIN205B 3 3 3BSC770010R0101 KTK-R6A/660V for PIN205B; min.QTY 10pcs Semiconductor fuses/Module * 3 3 DCA0012724P1 170M6813 Fuses for Cabinets are differ.* Cooling fan 1 1 DCA0012171P1 W2E200-HH38-06 * Fuses used in Encl. Converter 3 3 3ADV050092P20 170M6016 Module contains: 2Q 4Q 18.30 1000 A (400V-500V) CONVERTER DESCRIPTION 2Q 4Q CODE Fuses for Encl. Conv. w. OESA TYPE/DATA NOTES Thyristor modules 3 6 3ADC3400066P1 TT 570 N16KOF Power interface board 1 1 3ADT312500R1 SDCS-PIN 205B Repl. SDCS PIN-21 and PIN205 Fuse F101- F103 on PIN205B 3 3 3BSC770010R0101 KTK-R6A/660V for PIN205B; min.QTY 10pcs Semiconductor fuses/Module * 3 3 3ADC770010P9 170M6166 Fuses for Cabinets are differ.* Cooling fan 1 1 3ADT754016P1 W2E250-HL06-08 * Fuses used in Encl. Converter 3 3 3ADV050092P20 170M6016 VI A A - 8 Fuses for Encl. Conv. w. OESA DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Appendix A - Spare Parts List Item 19.00 to 24.00 Modules DCS500B / DCS600 Size A5 900A----2000A 19.01 Common Parts for A5 Modules DESCRIPTION 2Q 4Q CODE Temperature Sensor (R57) 1 1 3ADT710003P1 Module contains: 2Q 4Q 19.00 900 A (600V-690V) CONVERTER DESCRIPTION 2Q 4Q CODE Thyristor TYPE/DATA KTY 2K-M4-800 TYPE/DATA 6 12 DCA0012007P1 T459N24TOF Puls transformer board 1 2 3BSE004939R1 SDCS-PIN-41 A Power interface board 1 1 3BSE004940R1 SDCS-PIN-51 Semiconductor fuses 6 6 3ADC770009P7 170M6144 Cooling fan 1 1 3ADT754018P1 D2E 160-AH02-15 Module contains: 2Q 4Q 20.00 1200 A (400V-500V) CONVERTER DESCRIPTION 2Q 4Q CODE Thyristor TYPE/DATA 6 12 DCA0012015P1 T589N18TOF Puls transformer board 1 2 3BSE004939R1 SDCS-PIN-41 A Power interface board 1 1 3BSE004940R1 SDCS-PIN-51 Semiconductor fuses 6 6 3ADC770010P5 170M6162 Cooling fan 1 1 3ADT754018P1 D2E 160-AH02-15 Module contains: 2Q 4Q 21.00 1500 A (400V-500V) CONVERTER DESCRIPTION 2Q 4Q CODE Thyristor TYPE/DATA 6 12 DCA0012031P1 5STP18F1800 Puls transformer board 1 2 3BSE004939R1 SDCS-PIN-41 A Power interface board 1 1 3BSE004940R1 SDCS-PIN-51 Semiconductor fuses 6 6 3ADC770010P9 170M6166 Cooling fan 1 1 3ADT754018P1 D2E 160-AH02-15 Module contains: 2Q 4Q 22.00 1500 A (600V-690V) CONVERTER DESCRIPTION 2Q 4Q CODE Thyristor NOTES TYPE/DATA 6 12 DCA0012023P1 5STP16F2400 Puls transformer board 1 2 3BSE004939R1 SDCS-PIN-41 A Power interface board 1 1 3BSE004940R1 SDCS-PIN-51 Semiconductor fuses 6 6 3ADC770009P12 170M6149 Cooling fan 1 1 3ADT754018P1 D2E 160-AH02-15 DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f NOTES NOTES NOTES NOTES VI A A - 9 Appendix A- Spare Parts List Module contains: 2Q 4Q 23.00 2000 A (400V-500V) CONVERTER DESCRIPTION 2Q 4Q CODE Thyristor TYPE/DATA 6 12 3ADC340074P1 5STP1818F0003 Puls transformer board 1 2 3BSE004939R1 SDCS-PIN-41 A Power interface board 1 1 3BSE004940R1 SDCS-PIN-51 Semiconductor fuses 6 6 3ADC770010P12 170M6169 Cooling fan 1 1 3ADT754018P1 D2E 160-AH02-15 Module contains: 2Q 24.00 2000 A (600V-690V) CONVERTER DESCRIPTION 2Q CODE TYPE/DATA Thyristor 6 3ADC340075P1 5STP24H2800 Puls transformer board 1 3BSE004939R1 SDCS-PIN-41 A Power interface board 1 3BSE004940R1 SDCS-PIN-51 Semiconductor fuses 6 3ADC770009P13 170M6151 Cooling fan 1 3ADT754018P1 D2E 160-AH02-15 NOTES NOTES Item 19.10 to 24.10 Modules DCS500B / DCS600 Size C3 900A----2000A Module contains: 2Q 4Q 19.10 900 A (400V-500V) CONVERTER DESCRIPTION 2Q 4Q CODE TYPE/DATA Thyristor 6 12 DCA0012015P1 T589N18TOF Puls transformer board 1 2 3BSE004939R1 SDCS-PIN-41 A Power interface board 1 1 3BSE004940R1 SDCS-PIN-51 Semiconductor fuses 6 6 DCA0010683P1 170M6035 Cooling fan 1 1 3ADT754006P1 RD23P-4DW.4I.1R Module contains: 2Q 4Q 20.10 900 A (600V-690V) CONVERTER DESCRIPTION 2Q 4Q CODE Thyristor TYPE/DATA 6 12 DCA0012007P1 T459N24TOF Puls transformer board 1 2 3BSE004939R1 SDCS-PIN-41 A Power interface board 1 1 3BSE004940R1 SDCS-PIN-51 Semiconductor fuses 6 6 DCA0012791P1 170M6143 Cooling fan 1 1 3ADT754006P1 RD23P-4DW.4I.1R Module contains: 2Q 4Q 21.10 1200 A (400V-500V) CONVERTER DESCRIPTION 2Q 4Q CODE Thyristor TYPE/DATA 6 12 DCA0012015P1 T589N18TOF Puls transformer board 1 2 3BSE004939R1 SDCS-PIN-41 A Power interface board 1 1 3BSE004940R1 SDCS-PIN-51 Semiconductor fuses 6 6 DCA0010683P1 170M6035 Cooling fan 1 1 3ADT754006P1 RD23P-4DW.4I.1R VI A A - 10 NOTES NOTES NOTES DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Appendix A - Spare Parts List Module contains: 2Q 4Q 22.10 1500 A (400V-500V) CONVERTER DESCRIPTION 2Q 4Q CODE Thyristor TYPE/DATA 6 12 DCA0012031P1 5STP18F1800 Puls transformer board 1 2 3BSE004939R1 SDCS-PIN-41 A Power interface board 1 1 3BSE004940R1 SDCS-PIN-51 Semiconductor fuses 6 6 3ADC770010P9 170M6166 Cooling fan 1 1 3ADT754006P1 RD23P-4DW.4I.1R Module contains: 2Q 4Q 23.10 1500 A (600V-690V) CONVERTER DESCRIPTION 2Q 4Q CODE TYPE/DATA Thyristor 6 12 DCA0012023P1 5STP16F2400 Puls transformer board 1 2 3BSE004939R1 SDCS-PIN-41 A Power interface board 1 1 3BSE004940R1 SDCS-PIN-51 Semiconductor fuses 6 6 DCA0012805P1 170L7299 Cooling fan 1 1 3ADT754006P1 RD23P-4DW.4I.1R Module contains: 2Q 4Q 24.10 2000 A (400V-500V) CONVERTER DESCRIPTION 2Q 4Q CODE TYPE/DATA Thyristor 6 12 DCA0012031P1 5STP18F1800 Puls transformer board 1 2 3BSE004939R1 SDCS-PIN-41 A Power interface board 1 1 3BSE004940R1 SDCS-PIN-51 Semiconductor fuses 6 6 3ADC770010P9 170M6166 Cooling fan 1 1 3ADT754006P1 RD23P-4DW.4I.1R DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f NOTES former Id. Nr.DCA0012741P1 NOTES NOTES former Id. Nr.DCA0012741P1 VI A A - 11 Appendix A- Spare Parts List Item 25.00 to 38.00 Modules DCS500B / DCS600 Size C4 2050A----5150A 25.00 Common Parts for C4 Modules DESCRIPTION 2Q 4Q CODE TYPE/DATA Air Flow detector ( P1) 1 1 DCF1066659P1 P 33 AB Temperature Sensor (R57) 1 1 DCA0012139P3 KTY 10-6 M4 Module contains: 2Q 4Q 25.10 2050 A (600V-690V-790V) CONVERTER DESCRIPTION 2Q 4Q CODE NOTES (C4 / 950mm cable ) TYPE/DATA NOTES Thyristor 6 12 DCA0016142P1 5STP16F2800 Puls transformer board 1 2 3BSE004939R1 SDCS-PIN-41 A Power interface board 1 1 3BSE004940R1 SDCS-PIN-51 Semiconductor fuses 6 *)Cooling fan (Bus Bars"Left side") 1 6 DCA0017149P1 170M7031 1 DCA0018692P1 RG35P-4DK.7M.1R e.g. DCSxxx-2050-61L21P.. *)Cooling fan (Bus Bars"Right side 1 DCA0012660P1 RG35P-4DK.7M.1L e.g. DCSxxx-2050-61R21P.. 1 *) Select only one Cooling Fan for this C4 Modules Module contains: 2Q 4Q 26.00 2050 A (1000V) CONVERTER DESCRIPTION 2Q 4Q CODE TYPE/DATA 6 12 DCA0012058P1 5STP18L3600 Puls transformer board 1 2 3BSE004939R1 SDCS-PIN-41 A Power interface board 1 1 3BSE004940R1 SDCS-PIN-51 Semiconductor fuses 6 6 DCA0012864P1 170M7510 *)Cooling fan (Bus Bars"Left side") 1 1 DCA0018692P1 RG35P-4DK.7M.1R e.g. DCSxxx-2050-91L21P.. *)Cooling fan (Bus Bars"Right side 1 DCA0012660P1 RG35P-4DK.7M.1L e.g. DCSxxx-2050-91R21P.. Thyristor 1 NOTES *) Select only one Cooling Fan for this C4 Modules Module contains: 2Q 4Q 27.00 2500 A (400V-500V) CONVERTER DESCRIPTION 2Q 4Q CODE Thyristor TYPE/DATA 6 12 DCA0016169P1 5STP24L2800 Puls transformer board 1 2 3BSE004939R1 SDCS-PIN-41 A Power interface board 1 1 3BSE004940R1 SDCS-PIN-51 Semiconductor fuses NOTES 6 6 DCA0012848P1 170M7034 *)Cooling fan (Bus Bars"Left side") 1 1 DCA0018692P1 RG35P-4DK.7M.1R e.g. DCSxxx-2500-41L21P.. *)Cooling fan (Bus Bars"Right side 1 DCA0012660P1 RG35P-4DK.7M.1L e.g. DCSxxx-2500-41R21P.. 1 *) Select only one Cooling Fan for this C4 Modules VI A A - 12 DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Appendix A - Spare Parts List Module contains: 2Q 4Q 28.00 2500 A (600V-690V) CONVERTER DESCRIPTION 2Q 4Q CODE Thyristor TYPE/DATA NOTES 6 12 DCA0016169P1 5STP24L2800 Puls transformer board 1 2 3BSE004939R1 SDCS-PIN-41 A Power interface board 1 1 3BSE004940R1 SDCS-PIN-51 Semiconductor fuses 6 6 DCA0012848P1 170M7034 *)Cooling fan (Bus Bars"Left side") 1 1 DCA0018692P1 RG35P-4DK.7M.1R e.g. DCSxxx-2500-x1L21P.. *)Cooling fan (Bus Bars"Right side 1 DCA0012660P1 RG35P-4DK.7M.1L e.g. DCSxxx-2500-x1R21P.. 1 *) Select only one Cooling Fan for this C4 Modules Module contains: 2Q 4Q 29.00 2650 A (1000V) CONVERTER DESCRIPTION 2Q 4Q CODE TYPE/DATA Thyristor 6 12 DCA0012058P1 5STP18L3600 Puls transformer board 1 2 3BSE004939R1 SDCS-PIN-41 A Power interface board 1 1 3BSE004940R1 SDCS-PIN-51 Semiconductor fuses NOTES 6 6 DCA0012864P1 170M7510 *)Cooling fan (Bus Bars"Left side") 1 1 DCA0018692P1 RG35P-4DK.7M.1R e.g. DCSxxx-2650-x1L21P.. *)Cooling fan (Bus Bars"Right side 1 DCA0012660P1 RG35P-4DK.7M.1L e.g. DCSxxx-2650-x1R21P.. 1 *) Select only one Cooling Fan for this C4 Modules Module contains: 2Q 4Q 30.00 3200 A (790V) CONVERTER DESCRIPTION 2Q 4Q CODE TYPE/DATA 6 12 DCA0016169P1 5STP24L2800 Puls transformer board 1 2 3BSE004939R1 SDCS-PIN-41 A Power interface board 1 1 3BSE004940R1 SDCS-PIN-51 Semiconductor fuses 6 6 DCA0017271P1 170M7035 *)Cooling fan (Bus Bars"Left side") 1 1 DCA0018692P1 RG35P-4DK.7M.1R e.g. DCSxxx-3200-x1L21P.. *)Cooling fan (Bus Bars"Right side 1 DCA0012660P1 RG35P-4DK.7M.1L e.g. DCSxxx-3200-x1R21P.. Thyristor 1 NOTES *) Select only one Cooling Fan for this C4 Modules Module contains: 2Q 4Q 31.00 3200 A (1000V) CONVERTER DESCRIPTION 2Q 4Q CODE TYPE/DATA Thyristor 6 12 DCA0012066P1 5STP28L3600 Puls transformer board 1 2 3BSE004939R1 SDCS-PIN-41 A Power interface board 1 1 3BSE004940R1 SDCS-PIN-51 Semiconductor fuses 6 6 DCA0012872P1 170M7513 *)Cooling fan (Bus Bars"Left side") 1 *)Cooling fan (Bus Bars"Right side 1 1 DCA0018692P1 RG35P-4DK.7M.1R 1 DCA0012660P1 RG35P-4DK.7M.1L NOTES e.g. DCSxxx-3200-x1L21P.. e.g. DCSxxx-3200-x1R21P.. *) Select only one Cooling Fan for this C4 Modules DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f VI A A - 13 Appendix A- Spare Parts List Module contains: 2Q 4Q 32.00 3300 A (400V-500V) CONVERTER DESCRIPTION 2Q 4Q CODE TYPE/DATA NOTES Thyristor 6 12 DCA0016169P1 5STP24L2800 Puls transformer board 1 2 3BSE004939R1 SDCS-PIN-41 A Power interface board 1 1 3BSE004940R1 SDCS-PIN-51 Semiconductor fuses 6 6 DCA0017271P1 170M7035 *)Cooling fan (Bus Bars"Left side") 1 1 DCA0018692P1 RG35P-4DK.7M.1R e.g. DCSxxx-3300-x1L21P.. *)Cooling fan (Bus Bars"Right side 1 DCA0012660P1 RG35P-4DK.7M.1L e.g. DCSxxx-3300-x1R21P.. 1 *) Select only one Cooling Fan for this C4 Modules Module contains: 2Q 4Q 33.00 3300 A (600V-690V) CONVERTER DESCRIPTION 2Q 4Q CODE TYPE/DATA Thyristor 6 12 DCA0016169P1 5STP24L2800 Puls transformer board 1 2 3BSE004939R1 SDCS-PIN-41 A Power interface board 1 1 3BSE004940R1 SDCS-PIN-51 Semiconductor fuses NOTES 6 6 DCA0017271P1 170M7035 *)Cooling fan (Bus Bars"Left side") 1 1 DCA0018692P1 RG35P-4DK.7M.1R e.g. DCSxxx-3300-x1L21P.. *)Cooling fan (Bus Bars"Right side 1 DCA0012660P1 RG35P-4DK.7M.1L e.g. DCSxxx-3300-x1R21P.. 1 *) Select only one Cooling Fan for this C4 Modules Module contains: 2Q 4Q 34.00 4000 A (400V-500V) CONVERTER DESCRIPTION 2Q 4Q CODE Thyristor TYPE/DATA NOTES 6 12 DCA0016151P1 5STP27L1800 Puls transformer board 1 2 3BSE004939R1 SDCS-PIN-41 A Power interface board 1 1 3BSE004940R1 SDCS-PIN-51 Semiconductor fuses 6 6 DCA0012821P1 170M7026 *)Cooling fan (Bus Bars"Left side") 1 1 DCA0018692P1 RG35P-4DK.7M.1R e.g. DCSxxx-4000-x1L21P.. *)Cooling fan (Bus Bars"Right side 1 DCA0012660P1 RG35P-4DK.7M.1L e.g. DCSxxx-4000-x1R21P.. 1 *) Select only one Cooling Fan for this C4 Modules Module contains: 2Q 4Q 35.00 4000 A (600V-690V-790V) CONVERTER DESCRIPTION 2Q 4Q CODE TYPE/DATA Thyristor 6 12 DCA0016177P1 5STP33L2800 Puls transformer board 1 2 3BSE004939R1 SDCS-PIN-41 A Power interface board 1 1 3BSE004940R1 SDCS-PIN-51 Semiconductor fuses NOTES 6 6 DCA0012856P1 170M7036 *)Cooling fan (Bus Bars"Left side") 1 1 DCA0018692P1 RG35P-4DK.7M.1R e.g. DCSxxx-4000-x1L21P.. *)Cooling fan (Bus Bars"Right side 1 DCA0012660P1 RG35P-4DK.7M.1L e.g. DCSxxx-4000-x1R21P.. 1 *) Select only one Cooling Fan for this C4 Modules VI A A - 14 DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f Appendix A - Spare Parts List Module contains: 2Q 4Q 36.00 4000 A (1000V) CONVERTER DESCRIPTION 2Q 4Q CODE TYPE/DATA Thyristor 6 12 DCA0012082P1 5STP38N3600 Puls transformer board 1 2 3BSE004939R1 SDCS-PIN-41 A Power interface board 1 1 3BSE004940R1 SDCS-PIN-51 Semiconductor fuses 6 6 DCA0012881P1 170M7520 *)Cooling fan (Bus Bars"Left side") 1 1 DCA0018692P1 RG35P-4DK.7M.1R e.g. DCSxxx-4000-x1L21P.. *)Cooling fan (Bus Bars"Right side 1 DCA0012660P1 RG35P-4DK.7M.1L e.g. DCSxxx-4000-x1R21P.. 1 NOTES *) Select only one Cooling Fan for this C4 Modules Module contains: 2Q 4Q 37.00 4750 A (600V-690V-790V) CONVERTER DESCRIPTION 2Q 4Q CODE TYPE/DATA Thyristor 6 12 DCA0016193P1 5STP45N2800 Puls transformer board 1 2 3BSE004939R1 SDCS-PIN-41 A Power interface board 1 1 3BSE004940R1 SDCS-PIN-51 Semiconductor fuses NOTES 6 6 DCA0012856P1 170M7036 *)Cooling fan (Bus Bars"Left side") 1 1 DCA0018692P1 RG35P-4DK.7M.1R e.g. DCSxxx-4750-x1L21P.. *)Cooling fan (Bus Bars"Right side 1 DCA0012660P1 RG35P-4DK.7M.1L e.g. DCSxxx-4750-x1R21P.. 1 *) Select only one Cooling Fan for this C4 Modules Module contains: 2Q 4Q 38.00 5150 A (400 V-500 V) CONVERTER DESCRIPTION 2Q 4Q CODE Thyristor TYPE/DATA NOTES 6 12 DCA0016185P1 5STP45N2200 Puls transformer board 1 2 3BSE004939R1 SDCS-PIN-41 A Power interface board 1 1 3BSE004940R1 SDCS-PIN-51 Semiconductor fuses 6 6 DCA0012830P1 170M7028 *)Cooling fan (Bus Bars"Left side") 1 1 DCA0018692P1 RG35P-4DK.7M.1R e.g. DCSxxx-5150-x1L21P.. *)Cooling fan (Bus Bars"Right side 1 DCA0012660P1 RG35P-4DK.7M.1L e.g. DCSxxx-5150-x1R21P.. 1 *) Select only one Cooling Fan for this C4 Modules If you have any questions concerning spare parts, please contact your local ABB-agent! DCS 500 / DCS 600 Service Manual 3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f VI A A - 15
advertisement
Related manuals
advertisement