Avery Weigh-Tronix PLU Lite Installation and Operation Instructions
Add to My manuals18 Pages
Avery Weigh-Tronix Avery Weigh-Tronix ZK830 PLU Lite High Resolution Digital Checkweigher is an advanced weighing solution designed to streamline your weighing and data management processes. With its user-friendly interface and versatile features, the ZK830 PLU Lite offers precise weight measurements, extensive data storage, and seamless connectivity options.
The ZK830 PLU Lite boasts a high-resolution display, providing clear and accurate weight readings. Its large keypad and intuitive menu navigation make it easy to operate, even for users with minimal training. The checkweigher's capacity ranges from 300 grams to 6 kilograms, making it suitable for various weighing applications.
advertisement
PLU Lite
Software for the ZK830
Installation and Operation Instructions
AWT35-501790
Issue AC
Avery Weigh-Tronix is a trademark of the Illinois Tool Works group of companies whose ultimate parent company is Illinois Tool
Works Inc (“Illinois Tool Works”). Copyright © 2018 Illinois Tool Works. All rights reserved.
No part of this publication may be reproduced by making a facsimile copy, by the making of a copy in three dimensions of a two-dimensional work and the making of a copy in two dimensions of a three-dimensional work, stored in any medium by electronic means, or transmitted in any form or by any means, including electronic, mechanical, broadcasting, recording or otherwise without the prior written consent of the copyright owner, under license, or as permitted by law.
This publication was correct at the time of going to print, however Avery Weigh-Tronix reserves the right to alter without notice the specification, design, price or conditions of supply of any product or service at any time.
PLU_Lite_u_en_501791.book
Table of Contents
page
...................................................................................................................................... 3
Chapter 1 Introduction and Installation
................................................................................................... 4
................................................................................................................ 6
ZK830 PLU Lite User Instructions 3
Introduction and Installation
1 Introduction and Installation
This manual covers the installation and use of the PLU Lite software for communication and database management between your ZK830 and a PC. PLU Lite will provide basic
Product Look Up (PLU) creation, maintenance, and archiving for the ZK830 database.
The editor allows a user to add, subtract and save PLU information while you are not connected to the scale.
PLU lite allows you to automatically activate PLU’s by using a scanner attached to the
PC or by manually pressing a button to select the currently selected PLU.
1.1 System requirements
Windows 7, Windows 8 or Windows 10
One ZK830 only can operate with this software package via RS232 or Ethernet
Optional USB barcode scanner to connect through PC
The ZK830 firmware version must be at least 1.1.3.0 or greater
1.2 Start Up
When the PLU Lite application is installed and first powered up, there will be no license found. The user will need to follow the onscreen instructions to request a license from
Avery Weigh-Tronix. This license will lock the application to the PC on which the application is installed.
1.3 Licensing
After installation, when the product is run for the first time the following license screen will be shown:
4 ZK830 PLU Lite User Instructions
1.3 Licensing
Once completed filling in all the required fields, press Save to disk and save the
LicenseInformation.xml file to the file system. Make sure you know where the file is stored as you will need to send that file to Avery Weigh-Tronix.
Email the file to [email protected]
When you receive a license file back from Avery Weigh-Tronix press Load License and select the file from the local file system. If the email was sent to a different PC you must manually transfer the file between PCs. If the license file is correct, the PLU Lite program will then start automatically and you should not be prompted for a license file again.
Press Close to close the program.
ZK830 PLU Lite User Instructions 5
Setup and Operation
2 Setup and Operation
PLU Lite allows Ethernet or Serial interfaces to be used with the ZK830. Depending on your application, the following ZK830 settings will need to be setup.
2.1 PLU Lite Ethernet setup
This screen is the first that appears after licensing the software. The Setup menu allows you to configure the filename and the communications settings.
6
The filename field will be non-editable when an active data filename has been selected.
ZK830 PLU Lite User Instructions
2.2 ZK830 Ethernet setup
2.2 ZK830 Ethernet setup
Below are example Ztools screenshots you use to configure the indicator’s Ethernet settings.
The ZK830 must be configured for SMA protocol on the connected port.
ZK830 PLU Lite User Instructions 7
Setup and Operation
2.3 PLU Serial setup
2.4 ZK830 Serial setup
8
The ZK830 must be configured for SMA protocol on the connected port.
ZK830 PLU Lite User Instructions
2.5 Operation
This is the main screen of the PLU Lite software:
2.5 Operation
Live piece weights can be read from the indicator and saved in the database in real time. If you have an active PLU displayed in the Database editor, press Get live Piece
Weight to transfer the scales piece weight to the displayed PLU’s Piece Weight value.
Press the Save button to store the piece weight.
Press the Print button to print the live data from the indicator on a suitable printer once correctly configured and connected to the PC. The print data can be programmed via a single print format which is built up using flexible print tokens and free text.
2.5.1 Connect/Disconnect button
Once the ethernet or serial setup configurations are complete, see sections 2.1
, you need to connect the software to the scale by pressing the Connect button. The button will change to a Disconnect button. Use this to disconnect the scale from the software, if necessary.
ZK830 PLU Lite User Instructions 9
Setup and Operation
2.5.2 Adding a PLU
After the file has been created and a ZK830 system has been configured, select the
NEW button on the database screen to create a new PLU number.
The default tare value of 99999 disables the tare for the current product and when activated uses the tare of the previous product.
After you have validated that Part number, Description, Unit, Local scale and Remote scale tares have been entered properly, select the Save key.
A part number can also be added by scanning its barcode. If the part number already exists it will automatically be activated but, if it’s a new part number, the option of creating a new record in the database will be given. See the window below. Add the details as described above, then press Save .
10 ZK830 PLU Lite User Instructions
2.6 Menus
2.5.3 Using the ‘Search by’ function
Once PLUs are created, you can search for a particular PLU by Part Number or
Description. Use the Search by function on the main screen. First, select if you want to search by Part Number or Description then begin to type in a Part Number or
Description. The database will show any entries that match your search requirements.
You can put the cursor in the Search by box and use the scanner to scan in a part number or description to speed up your search.
2.5.4 Activating a PLU
Scan the barcode of the required part to activate a PLU on the indicator, or press the
Activate PLU button once you have selected the part from the main view.
2.5.5 Get Live Piece Weight
Once a PLU is active, press the Get Live piece weight button to read the piece weight from the scale and put it in the currently selected PLU’s value. You can then elect to
Save or Cancel the PLU.
2.5.6 Print
Once a PLU has been activated pressing the Print key will send the programmed text to the configured printer or to the screen depending on the printer setup.‘
2.6 Menus
2.6.1 FILE
The following menu items can be found under the File command:
New Allows you to create a new database.
Open Allows you to Open an existing CSV file.
Save Saves the current configuration and data to the hard drive of the PC
Save As Allows you to save the Database’s PLU data as a CSV file.
Exit Terminates the application
2.6.2 SETUP
The following menu items can be found under the Setup command:
Indicator Allows you to view or change the settings like IP address, com port of the PC, etc..
ZK830 PLU Lite User Instructions 11
Setup and Operation
Scanner
Printer
Print Format
Print Tokens
Allows you to view or change the scanner settings
Allows you to view or change the printer settings
Allows you to program a single print format to be printed when the
Print button is pressed
Allows you to change the print tokens used by the print format
2.6.3 HELP
About Lists the version and End User License Agreement information about the application.
The Screen will look similar to below once you have saved at least 1 PLU:
2.7 Scanner Setup
The Scanner Setup menu allows you to configure the serial parameters for the scanner.
12 ZK830 PLU Lite User Instructions
The scanner output format is the Part Number followed by a CR
2.7 Scanner Setup
ZK830 PLU Lite User Instructions 13
Setup and Operation
2.8 Printer Setup
The Printer Setup menu allows you to configure the printer.
14 ZK830 PLU Lite User Instructions
2.9 Print Format Setup
2.9 Print Format Setup
The Print Format Setup menu allows you to program the print format. The example below is for a Zebra GX420t printer.
An example label is shown below.
ZK830 PLU Lite User Instructions 15
Setup and Operation
2.10 Print Tokens Setup
The Print tokens setup allows you to configure the print token names that can be used in the print format. The defaults are shown below.
16 ZK830 PLU Lite User Instructions
Avery Weigh-Tronix USA
1000 Armstrong Dr.
Fairmont MN 56031 USA
Tel:507-238-4461
Fax:507-238-4195
Email: [email protected]
www.averyweigh-tronix.com
Avery Weigh-Tronix UK
Foundry Lane,
Smethwick, West Midlands,
England B66 2LP
Tel:+44 (0) 8453 66 77 88
Fax:+44 (0)121 224 8183
Email: [email protected]
www.averyweigh-tronix.com
advertisement
Related manuals
advertisement
Table of contents
- 3 Table of Contents
- 4 1 Introduction and Installation
- 4 1.1 System requirements
- 4 1.2 Start Up
- 4 1.3 Licensing
- 6 2 Setup and Operation
- 6 2.1 PLU Lite Ethernet setup
- 7 2.2 ZK830 Ethernet setup
- 8 2.3 PLU Serial setup
- 8 2.4 ZK830 Serial setup
- 9 2.5 Operation
- 9 2.5.1 Connect/Disconnect button
- 10 2.5.2 Adding a PLU
- 11 2.5.3 Using the ‘Search by’ function
- 11 2.5.4 Activating a PLU
- 11 2.5.5 Get Live Piece Weight
- 11 2.5.6 Print
- 11 2.6 Menus
- 11 2.6.1 FILE
- 11 2.6.2 SETUP
- 12 2.6.3 HELP
- 12 2.7 Scanner Setup
- 14 2.8 Printer Setup
- 15 2.9 Print Format Setup
- 16 2.10 Print Tokens Setup