advertisement
![Percussion Play Alto Quartet Ensemble Installation Instructions | Manualzz Percussion Play Alto Quartet Ensemble Installation Instructions | Manualzz](http://s1.manualzz.com/store/data/070877174_1-e3a9edf33bdc06b30b1db39b57ddf20f-360x466.png)
Ground Fixed
Freechimes
Alto/ Soprano
Page 1 of 4
Components:
Eye Straps
X2
M6x20mm
Secure Screw
X4
M8x40mm
Secure Screw
X4
BS EN 1176
Installation Instructions
1. Carefully lay 2 x legs on a level surface and check distance between legs is equal. Line up pre drilled holes in the backboards with the holes in legs and ensure the instrument is aligned square with the legs. Fix in place using M8x40mm screws supplied (see installation guide)
2. Attach Ground Fixings to base of legs (See Ground Fix Post
Installation Sheet)
3.Excavate 2 holes on site of installation minimum 500mm deep ( adjust depth according to age range for intended players)
6. Beaters can be fixed to
Steel posts with fixings provided
1.5m
Metric Conversion:
500mm/ 1 ft 7 11 /
900mm/ 2 ft 11 7 /
1100mm/ 3 ft 7 5
1.5m/ 59”
/
16
”
16
”
16
”
Weight of heaviest part 8.35kg
(Freechimes)
4. Carefully raise the instrument from the ground with legs attached and locate (lower) legs into holes making sure they are vertical and level prior to concreting in place. (See Ground
Fix Sheet)
5. Once happy with location and levels, fill holes using rapid hardening concrete. Be sure to compact concrete around legs and leave to dry according to manufactures guidelines
Pair Small
Beaters X1
Ground Fix
Components: x4
M10x200 Threaded Bar M10 Nut x8
Ground Surface
KS1 – 900mm
KS2 – 1100mm
1.5m
Install Instrument with 1.5m free space
(from widest point) around it.
KS1,2,
500mm
Spares available from percussionplay.com or from your local distributor
16 Kg
Assembly Guide PPFREC
Ground Fixed
Freechimes
Alto/ Soprano
Page 2 of 4
Thread Lock Solution
Required (Not Supplied)
Components:
Eye Straps
X2
M6x20mm
Secure Screw
X4
M8x40mm
Secure Screw
X4
BS EN 1176
Thread Lock Solution
Required (Not Supplied)
Pair Small
Beaters X1
Ground Fix
Components: x4
M10x200 Threaded Bar M10 Nut x8
Tools: x1
TX 30 Driver Bit x1
TX 40 Driver Bit
COMPONENTS LIST:
M10 Nut X8
M10x200 Threaded Bar X4
Saddle Strap X2
M6x20 Pin torx X4
M8 Lock washer X4
M8x40 Pin torx X4
Spares available from percussionplay.com or from your local distributor
16 Kg
Ground Fixed
Freechimes
Alto/ Soprano
Page 3 of 4
Ground Fix Post Installation
Foundations should not present a hazard. These foundations are recommended as a guide, for more information on foundation details for various surface see Part 7 of BS EN 1176.
1 2 3
Components: x4
M10x200 Threaded Bar x8
M10 BZP Nut
Thread Lock Solution
Required (Not Supplied)
4
5
Insert M10x 150 Threaded bar into pre drilled holes in Ground Fixing Post (1.1)
Fix M10x 150 Threaded bar in place using M10
Nuts
Excavate 7 holes with a
250mm diameter tapering down to 350mm diameter and 650mm depth
6 7 Ground fix tube protrudes 300mm from ground surface that inserts into the base of the chime post
250
Compact base of hole with
50mm of aggregate.
Lower ground Fix post attached to instrument into hole (check instrument straight and level before filling with concrete)
500mm min depth
Fix hole with fast drying concrete to manufacturers specifications.
Concrete
Aggregate
350
BS EN 1176
“
Metric Conversion:
50mm/ 2”
100mm/ 4”
250mm/ 10”
350mm/ 14”
500mm/ 1 ft 7 11
550mm/ 1 ft 9 21 /
/
16
”
32
Ground Fix Installation
Foundations should not present a hazard. These foundations are recommended as a guide, for more information on foundation details for various surface see Part 7 of BS EN 1176.
Ground Fixed
Freechimes
Alto/ Soprano
Page 4 of 4
(1.1)
250
Metric Conversion:
50mm/ 2”
250mm/ 10”
350mm/ 14”
“
500mm/ 1 ft 7 11
472mm/ 1 ft 6 37 /
/
16
”
64
“
709mm/ 2 ft 3 29 /
32
1
Carefully lay 2 x legs on a level surface.
Line up pre drilled holes in the backboards with the legs and ensure the instrument is aligned square with the legs. Fix in place using 8x70mm screws supplied
2
350
Excavate 2 holes with a 250mm diameter tapering down to 350mm diameter and minium 650mm depth
Minimum installation depth required 650mm, to set height of instrument bury deeper until optimum playing height is achieved.
3
Compact base of hole with 50mm of aggregate. Lower ground Fix posts attached to instrument into hole (check instrument straight and level, and at correct height before filling with concrete)
4 Fill holes with fast drying concrete to manufacturers specifications. If posts protrude above instrument they can be cut down
BS EN 1176
Instrument
Components: x8
M8 Nyloc Nut x4
M6x20 Security Screw x8
2 Part Cover
Cap x2
M6 Saddle Strap
Metric
Conversion:
250mm/ 10”
400mm/ 15 3/4”
550mm/ 21
21/32”
700mm/ 27 9/16”
850mm/ 33
15/32”
1.5m/ 59”
Ground Fixed
Duo
Page 1 of 3
Installation Instructions
(1.3)
(1.1)
(1.2)
1. Attach the steel legs to the base of the instrument with the M8 Nyloc Nuts and 2 part security caps. (1.1) (See
Assembly Guide)
2. Attach Ground Fixing posts to legs(1.2) (See Ground Fix
Post Installation Sheet)
3.Excavate 2 holes for the
Steel legs 250mm diameter by 400-550mm deep depending on Key stage, in desired location upon decision from customer.
4. Locate (lower) legs into holes making sure they are vertical and level prior to concreting in place.
5. Once happy with location of the Instrument, fill holes using rapid hardening concrete. Be sure to compact concrete around legs and leave to dry according to manufactures guidelines.
1.5m
KS1,2
KS1 – 700mm
KS2 – 850mm
Ground Surface
1.5m
Install Instrument with 1.5m free space
(from widest point) around it.
Weight of heaviest part 14kg (Duo)
Pair Small Red
Beaters X2
Ground Fix
Components:
6. Attach the 1 pair of beater to the saddle strap on the leg.
(1.3)
KS2 - 400mm
KS1 - 550mm x4
M10x200 Bolt M10 Nut x8
Spares available from percussionplay.com or from your local distributor
28 Kg
BS EN 1176
Assembly Guide PPDUO
Ground Fixed
Duo
Page 2 of 3
Instrument
Components: x8
M8 Nyloc Nut x4
M6x20 Security Screw x8
2 Part Cover
Cap x2
M6 Saddle Strap
Thread Lock Solution
Required (Not Supplied)
BS EN 1176
(1.1)
Thread Lock Solution
Required (Not Supplied)
Tools: x1
TX 30 Driver Bit x1
TX 40 Driver Bit
COMPONENTS LIST:
2 Part Cover Cap X8
M8 Nyloc nut X8
M10 Nut X8
M10x200 Threaded Bar X4
Saddle Strap X2
M6x20 Pin torx X4
PPDUO FRONT
Pair Small Red
Beaters X2
Ground Fix
Components: x4
M10x200 Bolt M10 Nut x8
PPDUO SIDE
Spares available from percussionplay.com or from your local distributor
28 Kg
Ground Fixed
Duo
Page 3 of 3
Ground Fix Post Installation
1
Foundations should not present a hazard. These foundations are recommended as a guide, for more information on foundation details for various surface see Part 7 of BS EN
1176.
2
Components: x4
M10x200 Bolt
M10 Nut x8
Metric
Conversion:
50mm/ 2”
250mm/ 10”
350mm/ 14”
400mm/ 16”
450mm/ 18”
(1.1)
Insert M10x 150 Threaded bar into pre drilled holes in Ground Fixing Post
Fix M10x 200 Threaded bar in place using M10 Nuts
3
4
5
250
Concrete
Excavate 6 holes with a
250mm diameter tapering down to 350mm diameter and 450mm depth
400mm min depth
Compact base of hole with
50mm of aggregate.
Lower ground Fix post attached to instrument into hole (check instrument straight and level before filling with concrete)
Fix hole with fast drying concrete to manufacturers specifications.
Aggregate
350
Duplicate points 1-5. Duo requires 2
Ground Fix Posts
BS EN 1176
Installation Instructions
Ground Fixed
Congas
Page 1 of 3
1. Attach the steel leg to each of the congas with the
M10x50 security screws, square washers and PU mounts. (1.1) (See Assembly
Guide)
2. Attach Ground Fixings to legs(1.2) (See Ground Fix Post
Installation Sheet)
1.5m
1.5m
Install Instrument with 1.5m free space
(from widest point) around it.
Instrument
Components: x4
M10x50 Security Screw x4
M10x50x3 Square washer
PU 200 Mount x2 x2
PU 250 Mount
Metric
Conversion:
250mm/ 10”
400mm/ 16”
850mm/ 33”
1.5m/ 59”
(1.1)
Weight of heaviest part 3.8kg
(Large drum Small Congas)
Weight of heaviest part 4.5kg
(Large drum Medium Congas)
Weight of heaviest part 5.2kg
(Large drum Large Congas)
BS EN 1176
Played with hands
(1.2)
3.Excavate1 hole for the
Steel leg 250mm diameter by
300mm deep, in desired location upon decision from customer.
4. Locate (lower) legs into hole making sure they are vertical and level prior to concreting in place.
5. Once happy with location of the Instrument, fill hole using rapid hardening concrete. Be sure to compact concrete around legs and leave to dry according to manufactures guidelines.
Ground Fix
Components: x2
M10x200 Bolt M10 Nut x4
S,M,L
Ground Surface
300mm
Small – 850mm
Medium – 850mm
Large- 850mm
Spares available from percussionplay.com or from your local distributor
14.8 Kg
15 Kg
20 Kg
Ground Fixed
Congas
Page 2 of 3
Assembly Guide PPCONG
PPCONG PLAN
Thread Lock Solution
Required (Not Supplied)
Tools: x1
TX 45 Driver Bit
(1.1)
Instrument
Components: x4
M10x50 Security Screw x4
M10x50x3 Square washer
PU 200 Mount x2 x2
PU 250 Mount
Thread Lock Solution
Required (Not Supplied)
Thread Lock Solution
Required (Not Supplied)
BS EN 1176
Played with hands
PPCONG FRONT
Ground Fix
Components: x2
M10x200 Bolt M10 Nut x4
PPCONG SIDE
COMPONENTS LIST:
M10x50 Pin torx X4
M10x50x3 square washer X4
M10 Nut X4
M10x200 Threaded Bar X2
PU MOUNT 200 X2
PU MOUNT 250 X2
Spares available form percussionplay.com or from your local distributor
14.8 Kg
15 Kg
20 Kg
Ground Fixed
Congas
Page 3 of 3
Ground Fix Post Installation
1 2
Components: x2
M10x200 Bolt x4
Metric Conversion:
50mm/ 2”
250mm/ 10”
350mm/ 14”
400mm/ 16”
450mm/ 18”
3
Insert M10x 200 Threaded bar into pre drilled holes in Ground Fixing Post
Fix M10x 200 Threaded bar in place using M10
Nuts
Foundations should not present a hazard. These foundations are recommended as a guide, for more information on foundation details for various surface see Part 7 of BS EN 1176.
Excavate a hole with a
250mm diameter tapering down to 350mm diameter and 350mm depth
4 5
250
Compact base of hole with
50mm of aggregate.
Lower ground Fix post attached of instrument into hole (check instrument straight and level before filling with concrete)
300mm min depth
Concrete
Fill hole with fast drying concrete to manufacturers specifications.
Aggregate
350
BS EN 1176
Ground Fixed
Emperor Chimes
Page 1 of 2
Instrument
Components:
Emperor
Chimes are preassembled
Metric Conversion:
100mm/ 4”
250mm/ 10”
600mm/ 24”
1.5m/ 59”
1785mm/ 70”
2490mm/ 98”
BS EN 1176
Installation Instructions
1. Attach Ground Fixing posts to legs(1.2) (See Ground Fix
Post Installation Sheet)
1.5m
1.5m
1.5m
Install Instrument with 1.5m free space
(from widest point) around it.
2.Excavate 6 holes for
Emperor chimes 250mm diameter by 600mm deep in desired location upon decision from customer.
2490mm
1785mm
3. Locate (lower) legs into holes making sure they are vertical and level prior to concreting in place. Chimes should be 100mm from ground surface.
4. Once happy with location of the chimes, fill holes using rapid hardening concrete. Be sure to compact concrete around legs and leave to dry according to manufactures guidelines.
Ground
Surface
100mm
600mm
Weight of heaviest part 25kg (XL Chime)
Played with hands
Ground Fix
Components: x12
M10x150 Bolt M10 Nut x24 x6
M10x50 Security Screw x6
M10 Barrel Nut
Spares available from percussionplay.com or from your local distributor
117 Kg
Ground Fixed
Emperor Chimes
Page 2 of 2
Components: x12
M10x150 Threaded Bar x24
M10 BZP Nut x6
M10 Barrel Nut x6
M10x50 Security Screw
Thread Lock Solution
Required (Not Supplied)
Ground Fix Post Installation
Foundations should not present a hazard. These foundations are recommended as a guide, for more information on foundation details for various surface see Part 7 of BS EN 1176.
1 2 3
Thread Lock Solution
Required (Not Supplied)
Tools: x2
TX 45 Driver Bit
4
Metric Conversion:
50mm/ 2”
100mm/ 4”
250mm/ 10”
350mm/ 14”
600mm/ 24”
650mm/ 26”
5
Insert M10x 150 Threaded bar into pre drilled holes in Ground Fixing Post
Fix M10x 150 Threaded bar in place using M10
(1.1)
6
Locate the Ground fix Post into the leg of the instrument.
7
Fix instrument to Ground fix post using M10 bolt and Barrel Nut and use thread locking solution to prevent fixings working loose.
Ground fix tube protrudes 300mm from ground surface that inserts into the base of the chime post
Chime base is 100mm from ground surface
250
Excavate 6 holes with a
250mm diameter tapering down to 350mm diameter and 650mm depth
600mm max depth
Compact base of hole with
50mm of aggregate.
Lower ground Fix post attached to instrument into hole (check instrument straight and level before filling with concrete)
Fix hole with fast drying concrete to manufacturers specifications.
Concrete
Aggregate
350
BS EN 1176
advertisement