Harris IconMaster Master Control Switcher Installation and Configuration Manual
โฆษณา
โฆษณา
Master Control Switcher
Hardware Installation and Configuration Manual
Edition K, for use with system software version 3.2
175-000287-00
IconMaster™
Master Control Switcher
Installation and Configuration Manual
Edition K, for use with system software version 3.2
February 2010
Copyright Information
Copyright 2005-2010 Harris Corporation, 1025 West NASA Boulevard,
Melbourne, Florida 32919-0001 U.S.A. All rights reserved. This publication supersedes all previous releases. Printed in Canada.
This product and related documentation are protected by copyright and are distributed under licenses restricting their use, copying, distribution, and decompilation. No part of this product or related documentation may be reproduced in any form by any means without prior written authorization of
Harris Corporation and its licensors, if any.
This publication could include technical inaccuracies or typographical errors.
Changes are periodically added to the information herein; these changes will be incorporated into new editions of the publication. Harris Corporation may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time.
Warranty Information
The limited warranty policy provides a complete description of your warranty coverage, limitations, and exclusions, as well as procedures for obtaining warranty service. To view the complete warranty, visit our website.
Contents
Preface
Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
Writing Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .x
Obtaining Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi
Unpacking/Shipping Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xii
Unpacking a Product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xii
Product Servicing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xii
Returning a Product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xii
Safety Terms and Symbols in this Manual . . . . . . . . . . . . . . . . . . xiii
Embedded Software License Agreement . . . . . . . . . . . . . . . . . . . . . . . . . . . xiv
Chapter 1: Introduction
Main Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Optional Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Chapter 2: Installation
IconMaster Main Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Optional Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Installation Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Sequence of Events for Installation . . . . . . . . . . . . . . . . . . . . . . . . .11
Tools You’ll Need . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Sample System Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Connecting the Main Panel and Optional Audio Panel . . . . . . . . . .21
Mounting the Control Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Connecting Main Control Panel Components . . . . . . . . . . . . . . . . .28
Installing Standard NEO Modules (MKE-3901 and MGI-3903) . .31
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
iii
Contents
iv
Installing Optional NEO Modules (MKE-3901-FX and
MKA-3901) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
Installing the Optional MKA-3901 Submodule . . . . . . . . . . . . . . . .37
Installing the Optional MKE-3901-FX Submodule . . . . . . . . . . . . .37
Installing the NEO Frame into a Rack . . . . . . . . . . . . . . . . . . . . . . .37
Connecting NEO Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
MKE-3901 Back Module Connections . . . . . . . . . . . . . . . . . . . . . .38
MKA-3901 Back Module Connections . . . . . . . . . . . . . . . . . . . . . .40
ICONM-BO-V Video Breakout Module . . . . . . . . . . . . . . . . . . . . .43
ICONM-BO-VAB Balanced Audio Module . . . . . . . . . . . . . . . . . .54
ICONM-BO-VAC Coaxial Audio Module . . . . . . . . . . . . . . . . . . .56
Video Relay Bypass Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
Connecting Optional GPI Input and Output Devices . . . . . . . . . . . . . . . . . . .59
Connecting the eBox to the IconMaster . . . . . . . . . . . . . . . . . . . . .59
Disassembling the IconMaster . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
Removing the Bezel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
Installing the Fader Bar Assembly . . . . . . . . . . . . . . . . . . . . . . . . . .64
Assembling the Handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
Chapter 3: Module Configuration
Navigating the MKE-3901 Operator and All Lists . . . . . . . . . . . . . . . . . . . .68
Operator, All, and Setup Parameter Lists . . . . . . . . . . . . . . . . . . . . . . . . . . . .69
Operator and All Lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69
Setup Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72
MKE-3901 LEDs and Module Indicators . . . . . . . . . . . . . . . . . . . .73
MGI-3903 LEDs and Module Indicators . . . . . . . . . . . . . . . . . . . . .75
Chapter 4: Router Connections
System Configurations—NEO Routers . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
Sample Configuration 1: IconMaster System with Internal
Video NSM Router and Optional ICONM-BO-V Module . . . . . . .79
Sample Configuration 2: IconMaster System with Single Channel
Audio and Video NSM Routers and Optional ICONM-BO-VAC
Sample Configuration 3: IconMaster System with Internal (Two
Channel) Audio and Video NSM Routers and Optional
ICONM-BO-VAC Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .87
System Configurations—Panacea Routers . . . . . . . . . . . . . . . . . . . . . . . . . . .90
Sample Configuration 1: IconMaster System, External Panacea Video
Router, Optional ICONM-BO-V Module . . . . . . . . . . . . . . . . . . . .91
Sample Configuration 2: IconMaster System, External Panacea
Video Router, Optional ICONM-BO-V Module, Optional
SPT-LSERIAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .94
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Contents
Sample Configuration 3: IconMaster System, External Panacea
Clean/Quiet Switch Video Router, Optional ICONM-BO-V Module,
Optional SPT-LSERIAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99
Sample Configuration 4: IconMaster System, External Panacea
(Single Channel) Audio and Video Routers, Optional
ICONM-BO-VAC Module, Optional SPT-LSERIAL . . . . . . . . .102
Sample Configuration 5: IconMaster System with External
Panacea (Two Channel) Audio and Video Routers, Optional
ICONM-BO-VAC Module, Optional SPT-LSERIAL . . . . . . . . .106
System Configurations—Platinum Routers . . . . . . . . . . . . . . . . . . . . . . . . .110
Sample Configuration 1: IconMaster System, External Platinum
Router, Optional ICONM-BO-V Module . . . . . . . . . . . . . . . . . . .111
Sample Configuration 2: IconMaster System, External Platinum
Router, Optional CENTRIO, Optional JLCooper eBox, Optional
ICONM-BO-V Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .114
Chapter 5: Configuring IP Addresses
Setting the IP Address for the MKE-3901 Module . . . . . . . . . . . . . . . . . . .119
Setting the IP Address for the MGI-3903 Module . . . . . . . . . . . . . . . . . . . .120
Changing the Control Panel IP Address . . . . . . . . . . . . . . . . . . . . . . . . . . . .120
Set the IP Address for the 3901RES-E Module . . . . . . . . . . . . . . . . . . . . . .121
Network Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .122
Operating Standard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .122
System Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .122
Chapter 6: Connecting an IconMaster to an EAS Device
Chapter 7: Machine Control
Connecting for Machine Control Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127
Chapter 8: Automation Setup
Connecting a DAL Harris Automation System to IconMaster . . . . . . . . . .129
D-Series System Capabilities With IconMaster . . . . . . . . . . . . . . . . . . . . . .130
Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130
Configuring IconMaster to Ignore Automation Commands on Specific Key
Setting Up Automation Key Masks . . . . . . . . . . . . . . . . . . . . . . . .136
Important Considerations for Automation Key Masks . . . . . . . . .138
Automation Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
Chapter 9: Configuring IconMaster
Default Configuration Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .142
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
v
Contents
vi
System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .143
Tools You Will Need . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .143
Installing the IconMaster Configuration Utility . . . . . . . . . . . . . .143
Removing IconMaster Configuration Software . . . . . . . . . . . . . . .144
Ethernet Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145
Configuring a PC Monitor for Best Display . . . . . . . . . . . . . . . . .145
Frame Configuration Menu Groups . . . . . . . . . . . . . . . . . . . . . . . .146
Panel Menu Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .146
Network Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .146
Operating Standard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .147
System Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .147
Creating an ICU Configuration File . . . . . . . . . . . . . . . . . . . . . . .147
Opening an Existing ICU Configuration File . . . . . . . . . . . . . . . .149
Saving Databases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149
Uploading Databases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149
Primary Input Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .151
Audio Configuration Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . .153
Audio Over Matrix Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .157
Aux Bus (Auxiliary Bus Configuration) Settings . . . . . . . . . . . . .158
Transition Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .162
Effects Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .164
Quick Select Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169
Audio Cluster Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175
Keyer Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .176
Machine Control Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177
GPI Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180
GPO Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .182
Genlock and Standard Settings . . . . . . . . . . . . . . . . . . . . . . . . . . .184
Router Configuration Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . .187
System Configuration Settings . . . . . . . . . . . . . . . . . . . . . . . . . . .189
Automation Configuration Settings . . . . . . . . . . . . . . . . . . . . . . . .193
Network Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .194
License Management Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . .195
Serial Port Configuration Settings . . . . . . . . . . . . . . . . . . . . . . . . .196
Multiviewer Configuration Settings . . . . . . . . . . . . . . . . . . . . . . .197
Clock and Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .200
Panel Network Configuration Settings . . . . . . . . . . . . . . . . . . . . .203
Button Configuration Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . .204
LTC Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .206
Quick Configuration Quick Reference Chart . . . . . . . . . . . . . . . . . . . . . . . .207
Chapter 10: Enabling a Router Database for Use with an
IconMaster System
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Contents
Defining the IconMaster Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . .217
Preparing the IconMaster Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . .224
Changing or Editing the Router Database . . . . . . . . . . . . . . . . . . . . . . . . . .232
Chapter 11: Troubleshooting
IconMaster Troubleshooting Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . .235
Breakout Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .235
Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .235
Video Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .235
Video Output is not Valid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .236
Internal Router Control (NEO NSM) . . . . . . . . . . . . . . . . . . . . . .236
External Router Control (Panacea, Platinum, EDGE) . . . . . . . . . .236
Audio Overs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .236
Software/Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .237
Cannot PING the IconMaster Components From a Computer . . .237
RCP Cannot Connect To An IconMaster Channel (MKE) . . . . . .237
Cannot Communicate to the Primary Router . . . . . . . . . . . . . . . . .237
Cannot Control the Internal (Logo) Keyers . . . . . . . . . . . . . . . . . .238
Cannot Control the External Keyers . . . . . . . . . . . . . . . . . . . . . . .239
Verifying the IconMaster Software Version . . . . . . . . . . . . . . . . .240
Changing IP Address for the Control Panel . . . . . . . . . . . . . . . . . .240
Identifying Fader Bar Relative Positions . . . . . . . . . . . . . . . . . . . .241
Getting Help from Customer Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .241
Chapter 12: Specifications
Serial Digital Video . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .244
Analog Video Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .244
Digital Video . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .245
System Video Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .245
Embedded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .246
Discrete Audio for Audio Over . . . . . . . . . . . . . . . . . . . . . . . . . . .246
Discrete AES Audio Bus A and B . . . . . . . . . . . . . . . . . . . . . . . . .247
Audio Processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .248
AES User and Configuration Bits . . . . . . . . . . . . . . . . . . . . . . . . .248
Monitoring Audio Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .248
VANC Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .248
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
vii
Contents
Index
viii IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Preface
Manual Information
Purpose
This manual details the features, installation procedures, configuration procedures, and specifications of the IconMaster master control switcher.
Audience
Revision History
Table P-1. Revision History
Edition
Preliminary 1
This manual is written for engineers, technicians, and operators responsible for the installation and setup of the IconMaster master control switcher.
Preliminary 2, for use with System
Software Release 1.0.1
Edition A, for use with System
Software Release 1.1
Edition B, for use with System
Software Release 1.2
Edition C, for use with System
Software Release 1.4
Software Contents
• Content Editor 1.0.0
• LogoCreator 3.1.1
• IconMaster GUI 1.0.0
• IconSet Configuration Utility 1.0.0
• Content Editor 1.0.0
• LogoCreator 3.1.1
• IconLogo SoftPanel 1.0.0
• IconSet Configuration Utility 1.0.0
• Content Editor 1.0.0
• LogoCreator 3.1.1
• IconLogo SoftPanel 1.0.7
• IconMaster Configuration Utility 1.0.0.48
• Content Editor 1.0.0
• LogoCreator 3.1.1
• IconLogo SoftPanel 1.0.7
• IconMaster Configuration Utility 1.0.0.62
• Content Editor 1.0.0
• LogoCreator 3.1.1
• IconLogo SoftPanel 1.0.7
• IconMaster Configuration Utility 1.0.0.70
Date
December 2005
February 2006
March 2006
June 2006
September 2006
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
ix
Preface
Table P-1. Revision History (Continued)
Edition
Edition D, for use with System
Software Release 1.5
Edition E, for use with System
Software Release 2.0
Edition F, for use with System
Software Release 2.0.1
Edition G, for use with System
Software Release 2.1
Edition H, for use with System
Software Release 2.20
Edition I, for use with System
Software Release 3.0
Edition J, for use with System
Software Release 3.1
Software Contents
• Content Editor 1.0.0
• LogoCreator 3.1.1
• IconLogo SoftPanel 1.0.7
• IconMaster Configuration Utility 1.5.0.3
• Content Editor 1.0
• LogoCreator 4.0
• IconLogo SoftPanel 1.0
• IconMaster Configuration Utility 2.0
• Content Editor 1.0
• LogoCreator 4.0
• IconLogo SoftPanel 1.0
• IconMaster Configuration Utility 2.0.1
• Content Editor 1.1
• LogoCreator 4.0
• IconLogo SoftPanel 1.0
• IconMaster Configuration Utility 2.1
• Content Editor 1.1
• LogoCreator 4.1
• IconLogo SoftPanel 1.0.7
• IconMaster Configuration Utility 2.2
• Content Editor 1.1
• LogoCreator 4.1
• IconLogo SoftPanel 1.0.7
• IconMaster Configuration Utility 3.0
• Content Editor 1.3.1
• LogoCreator 4.2
• IconLogo SoftPanel 1.09
• IconMaster Configuration Utility 3.1
Date
December 2006
May 2007
June 2007
July 2007
March 2008
June 2008
January 2009
Writing Conventions
To enhance your understanding, the authors of this manual have adhered to the following text conventions:
Table P-2. Writing Conventions
Term or
Convention
Bold
Description
Italics
Indicates dialog boxes, property sheets, fields, buttons, check boxes, list boxes, combo boxes, menus, submenus, windows, lists, and selection names
Indicates E-mail addresses, the names of books or publications, and the first instances of new terms and specialized words that need emphasis
x IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Preface
Table P-2. Writing Conventions (Continued)
Term or
Convention
CAPS
Description
Code
> hyperlink
Internet address
Note
Indicates a specific key on the keyboard, such as ENTER, TAB,
CTRL, ALT, or DELETE
Indicates variables or command-line entries, such as a DOS entry or something you type into a field
Indicates the direction of navigation through a hierarchy of menus and windows
Indicates a jump to another location within the electronic document or elsewhere
Indicates a jump to a Web site or URL
Indicates important information that helps to avoid and troubleshoot problems
Obtaining Documents
Product support documents can be viewed or downloaded from our website.
Alternatively, contact your Customer Service representative to request a document.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
xi
Preface
Unpacking/Shipping Information
Unpacking a Product
This product was carefully inspected, tested, and calibrated before shipment to ensure years of stable and trouble-free service.
1. Check equipment for any visible damage that may have occurred during transit.
2. Confirm that you have received all items listed on the packing list.
3. Contact your dealer if any item on the packing list is missing.
4. Contact the carrier if any item is damaged.
5. Remove all packaging material from the product and its associated components before you install the unit.
Keep at least one set of original packaging, in the event that you need to return a product for servicing.
Product Servicing
IconMaster systems are not designed for field servicing. Except for certain designated options as described in this manual, all hardware upgrades, modifications, or repairs require you to return the product to the Customer
Service center.
Returning a Product
In the unlikely event that your product fails to operate properly, please contact
Customer Service to obtain a Return Authorization (RA) number, then send the unit back for servicing.
Keep at least one set of original packaging in the event that a product needs to be returned for service. If the original package is not available, you can supply your own packaging as long as it meets the following criteria:
• The packaging must be able to withstand the product’s weight.
• The product must be held rigid within the packaging.
• There must be at least 2 in. (5 cm) of space between the product and the container.
• The corners of the product must be protected.
Ship products back to us for servicing prepaid and, if possible, in the original packaging material. If the product is still within the warranty period, we will return the product prepaid after servicing.
xii IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Preface
Safety
Carefully review all safety precautions to avoid injury and prevent damage to this product or any products connected to it. If this product is rack-mountable, it should be mounted in an appropriate rack using the rack-mounting positions and rear support guides provided. It is recommended that each frame be connected to a separate electrical circuit for protection against circuit overloading. If this product relies on forced air cooling, it is recommended that all obstructions to the air flow be removed prior to mounting the frame in the rack.
If this product has a provision for external earth grounding, it is recommended that the frame be grounded to earth via the protective earth ground on the rear panel.
IMPORTANT! Only qualified personnel should perform service procedures.
Safety Terms and Symbols in this Manual
WARNING
Statements identifying conditions or practices that may result in personal injury or loss of life. High voltage is present.
CAUTION
Statements identifying conditions or practices that can result in damage to the equipment or other property.
Terms and Symbols on the Product
DANGER: High voltage; indicates a personal injury hazard immediately accessible as one reads the marking.
WARNING: Indicates a personal injury hazard not immediately accessible as one reads the marking.
CAUTION: Indicates a hazard to property including the product or to take Attention and refer to the manual.
Protective ground (earth) terminal.
Fuse. Replace with same type and rating of fuse.
Observe precautions for handling electrostatic sensitive devices.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
xiii
Preface
Embedded Software License Agreement
The software embedded in this product incorporates the VxWorks Run-Time
Module, and the following paragraphs are applicable. You are prohibited from: a.
copying the Run-Time Module, except for archive purposes consistent with your archive procedures; b. transferring the Run-Time Module to a third party apart from the product containing the Run-Time Module; c.
modifying, decompiling, disassembling, reverse engineering or otherwise attempting to derive the source code of the Run-Time
Module; d. exporting the Run-Time Module or underlying technology in contravention of applicable U.S. and foreign export laws and regulations; and e.
using the Run-Time Module other than in connection with operation of the product in which it is embedded.
Any further distribution of the Run-Time Module is subject to the same restrictions set forth herein. Wind River Systems, Inc. and its licensors are third party beneficiaries of the End User License Agreement and the provisions related to the Run-Time Module are made expressly for the benefit of, and are enforceable by, Wind River Systems, Inc. and its licensors.
The laws of the Province of Ontario shall govern this Agreement. Updated
January, 2005.
xiv IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 1
Introduction
Overview
The IconMaster modular master control switcher provides, in a modular format, the ability to combine critical master control functions with multi-integrated branding. IconMaster is based on our industry-leading NEO modular platform.
It is the only control that can be combined with other advanced applications to create a complete, self-contained channel release system.
This manual is part of a two-part set. Hardware installation and configuration procedures are provided in one manual, and control panel operation and configuration procedures are provided in the other manual. This manual provides detailed information on installing and configuring the hardware components in your IconMaster system. A complete setup will include
• Installing the IconMaster control panel
• Installing optional NEO modules
• Mounting a NEO frame in a rack
• Configuring NEO modules
• Connecting internal or external routers
• Connecting external Ethernet to serial and GPI interface devices
• Configuring control panel components (this information is provided in a separate manual)
• Control panel operations (this information is provided in a separate manual)
• Optional software installation and operation (this information is provided in a separate manual)
Each of these topics is covered in the IconMaster manual set. In some cases, however, you will be referred to another manual for more detailed information.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
1
Chapter 1: Introduction
Product Description
2
Figure 1-1. IconMaster Control Panel (with Optional Audio Control
Panel)
The IconMaster features a 12-input desk-mount or rack-mount control panel with LED buttons for bus selection and transitions as well as fully-configurable
LCD buttons. An “intelligent” audio control panel, and touch-screen configuration and control are available as options.
IconMaster is both SD and HD-ready. You can migrate from an SD master control to an HD master control via a straightforward configuration setting.
With IconMaster, flexibility is a core feature. With assignable, two-channel, squeeze back position, you have the power to choose. Internal or external routing is offered with 12 or 22 inputs, and with or without emergency bypass routing.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 1: Introduction
IconMaster features four internal and two external key layers for branding.
Features supported include static and animated logos, analog and digital clock capability, crawls, EAS (Emergency Alert System) and Amber Alert. The
IconMaster is also available without internal logo branding layers. This product,
IconMaster Lite, has two external key and fill inputs, and two Audio Over inputs. (The MGI-3903 IconLogo branding module is available as an upgrade for IconMaster Lite.)
Product Features
Main Features
• SD or HD configurable with no hardware changes
• Upgrade from IconLogo branding to IconMaster Master Control
• Assignable (two-channel) squeezeback position option
• Desk- or rack-mount control panel
• Industry-standard buttons with LEDs for bus selection and transitions
• User configurable LCD buttons
• Fader bar option
• Multi-channel modular design
• Two NEO-slot solution, or three slots with addition of audio monitoring option (embedded audio with external routing)
• Up to six channels in 3RU
• Operate multiple channels from single panel
• Full next-event preview
• 6 keyers
• 2 external, key/fill
• 4 internal branding keys
1
• Static and animated logos
• Analog and digital clocks
• Text crawls and EAS/Amber Alert option
• Flexible audio options
• 8 channels discrete AES audio
• 16 channels embedded audio
• 2 audio overs with dedicated EAS inputs
• Full-channel audio assignment and processing
• Internal audio logo playback by attaching .WAV files to a logo
• Dynamic assignable audio profiles
• Full support for CCS-P (i.e., Navigator and NUCLEUS) control
• Machine control
1
Not available on IconMaster Lite models.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
3
Chapter 1: Introduction
• Router control over Ethernet or serial RS-232/422
• Drive under monitor displays using serial tally protocol
• Aux bus support of multi-level sources and destinations
• On-screen logo positioning
• Internal logo memory storage expanded to 4 Gb (via the MGI-3903)
• Primary/secondary assignment and control of up to eight IconMaster channels for slaved operation
• Timer/clock on RCP
• RCP available as SNTP time server from clock module reference
• Assignable names to programmable Quick Select macro functions, and to
GPO events
Optional Features
• Fader bar
• Intelligent audio control panel
• Internal or external routing with 12 or 22 inputs
• External routing with or without emergency backup routing
• Relay bypass with dedicated bypass input
• 2-channel video squeezeback option
• Text crawl with dynamic data insertion
• RSS and ODBC connectivity
• EAS and Amber Alert (Emergency Alert System) insertion
• Fully- featured “soft” control panel
• Direct control of multiviewers
• Up to 66 GPI inputs and up to 61 GPI outputs via the use of an optional
Ethernet to serial and GPI interface
• Support for any multiviewer on the market, with special support for Harris
CENTRIO and Predator Multiviewers
4 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 1: Introduction
IconMaster Components
A complete IconMaster setup consists of main components, optional items,
NEO modules, and routers.
Main Components
Hardware Components
• A main control panel with one power supply (For redundant power supply operation, two power supply units may be used)
• A 3RU NEO frame with redundant power supplies
• An MKE-3901 mixer/keyer module
• An MGI-390x IconLogo graphics module
Software Components
• Icon Series Soft Tools CD, which includes
• IconMaster Configuration Utility (ICU)
• Content Editor
• LogoCreator
• IconLogo Soft Panel
Optional Items
• An additional power supply (for redundant power supply operation)
• An audio control panel
• An MKE-3901-FX effects optional submodule (for MKE-3901 module)
• An MKA-3901 balanced audio module
• An ICONM-BO-V video breakout module
• A balanced (ICONM-BO-VAB) or a coaxial (ICONM-BO-VAC) audio/video breakout module
• NEO 3901RES-E resource module for CCS-P control and display
• An internal router, such as NEO NSM routers
• An external router, such as Platinum, Integrator, or Panacea
• A general purpose interface box, such as a JLCooper Electronics eBOX™
Quad Serial to Ethernet Interface
1
1 eBOX is a trademark of JLCooper Electronics
.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
5
Chapter 1: Introduction
System Setup
The types of components and options you purchased will determine the complexity of your installation and configuration.
includes the sequences of events for the most common IconMaster installation situations. Please see
page 11 for a listing of these scenarios.
About this Manual
This IconMaster manual involves hardware installation and configuration.
Control panel operation, as well as icon software installation, configuration, and operation, are covered in a separate manual.
6 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 2
Installation
Overview
IconMaster is a cost-effective modular master control and branding solution beyond the conventional, offering the ability to combine critical master control functions with multi-layer integrated branding, all in a modular card format.
The IconMaster master control switcher is controlled by a control panel, automation, or general purpose inputs. This chapter is designed to help install and set up the IconMaster frame modules, control panel, and all relevant interconnections between the frame and panel.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
7
8
Chapter 2: Installation
Pre-Installation Information
IconMaster Main Components
• Main control panel with one power supply
• MKE-3901 mixer/keyer module
• MGI-3903 IconLogo graphics module
• IconMaster Soft Tools CD, including IconMaster configuration utility
The IconMaster configuration utility software requires a separate Pentium
III 1GHz (or equivalent) PC with the following minimum requirements:
• 512 Mb RAM
• 10 Gb fixed disk drive space
• 10/100 Ethernet card
• Microsoft
®
Windows
®
2000 or Windows XP
1
operating systems
Optional Equipment
The following options are available for use with the IconMaster system. You may order these options separately and install them yourself, or you may order them at the same time as your IconMaster system so that they will be factory-installed and -configured.
• Additional power supply (for redundant power supply operation)
• Audio control panel
• Fader bar
• MKE-3901-FX effects optional submodule (for MKE-3901 module)
• MKA-3901-B balanced audio module
• ICONM-BO-V video breakout module
• ICONM-BO-VAB balanced audio breakout module
• ICONM-BO-VAC coaxial audio breakout module
• Internal routers (such as NEO NSM 7×2 routers)
• External routers, including Harris Platinum and Panacea routers, in addition to non-Harris third-party routers
• CENTRIO multiviewer output module (in a Platinum frame)
• Predator multiviewer
• JLCooper Electronics eBOX Quad Serial to Ethernet Interface
2
1. Windows 2000 and Windows XP are either registered trademarks or trademarks of Microsoft
Corporation in the United States and/or other countries. Currently the IconMaster utilities do not operate with Microsoft Vista operating system.
2. “eBOX” is a trademark of JLCooper Electronics, El Segundo, California, USA
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 2: Installation
shows how an IconMaster system setup works. Each installation component of this setup (except for the customer-supplied PC) is explained in more detail in sequent sections.
Audio control panel
(optional)
Main control panel
MKE-3901 to/from control panel on Ethernet (directly or via switch; switch must be 10Base-T or 10/100Base-
T—not 100 Base-T)
Customer-supplied PC running IconMaster
Configuration Utility and
Navigator software on
Windows® 2000 or
Windows® XP
Ethernet switch
To/from MGI- 3901/ MGI-3903
IconLogo SoftPanel, and
IconMaster configuration utility software via switch
FR-3923 NEO frame with redundant power supply
Modules are installed on one side in the following order:
1. MKA-3901 (optional)
3. MGI-3901 / MGI-3903
Modules must be connected to one another before installation.
Figure 2-1. IconMaster Components
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
9
Chapter 2: Installation
Installation Notes
• All IconMaster components must be mounted in an area where there is unrestricted air movement. Except for the MKE, MGI, and MKA modules
(which are mounted in standard NEO frames) no fan cooling is required.
• The two control panels of the IconMaster system are designed for desk and tabletop operation, or for use in a standard equipment rack.
• For maximum efficiency and reliability, IconMaster control panels should be operated in an ambient temperature between 68° and 86°F (20° to 30°C) non-condensing.
• IconMaster control panels communicate with the MKE-3901 via an
Ethernet network. On the same network, the MGI-3903 also connects to the
PC that hosts the IconMaster configuration utility software.
• If your network includes a switch, the switch must be 10Base-T or
10/100Base-T. The system will not function on 100Base-T.
• A NEO resource module is not required for IconMaster to be configured and work correctly.
• NEO frames require an ambient temperature between 32° and 122°F (0° and 45°C.) See the technical manual of your PC for information on the operating temperatures of the computer.
• NEO modules used in an IconMaster system must be connected together in the following top-to-bottom order before being inserted in a NEO frame:
1. MKA-3901 (optional)
2. MKE-3901 (with optional MKE-3901-FX submodule)
3. MGI-3903
Because the modules are physically connected together, they must all be installed on the same side of the frame.
CAUTION
If your IconMaster package was not factory-installed in a NEO frame, ensure that you use the provided screws to secure the modules together before they are inserted in the frame.
10 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 2: Installation
Sequence of Events for Installation
For a fully functional IconMaster system, you must install and configure the hardware components, and initialize certain settings. (Your particular installation may or may not include all of these steps, depending on which options you purchased.) After the installation is complete, you will need to configure the hardware modules, internal and external routers, and control panel components. These configuration tasks are explained in separate chapters.
The sequence of events that you will follow is determined by the system setup that you ordered. The simplest sequence is if you have ordered all of your components at the same time. The most complicated sequence is if you ordered all of your components at different times. The following scenarios outline the sequences of events for the most common IconMaster installation situations.
Each step in the sequence is matched with a page number that will direct you to the manual section that explains how to perform that step. Find the chart that most closely matches your situation, and use it to determine your particular sequence of events.
•
All Components Ordered at the Same Time and Preinstalled; Internal
•
All Components Ordered at the Same Time and Preinstalled; External
•
All Components Ordered at the Same Time and Preinstalled; Platinum
Router, CENTRIO. eBox: see page 13
•
•
•
•
Audio Control Panel Ordered Separately, Optional Modules Ordered
Separately; Internal (NSM) Routers Ordered Separately: see page 15
•
Audio Control Panel Ordered Separately, Optional Modules Ordered
Separately; Internal (NSM) Routers Preinstalled: see page 15
•
Audio Control Panel Ordered Separately, Optional Modules Ordered
Separately; External Router: see page 16
•
Audio Control Panel Ordered Separately, Optional Modules Ordered
Separately; Platinum Router, CENTRIO, eBox: see page 16
•
Audio Control Panel Ordered Separately, Fader Bar Ordered Separately,
Optional Modules Ordered Separately; Internal (NSM) Routers
•
Audio Control Panel Ordered Separately, Fader Bar Ordered Separately,
Optional Modules Ordered Separately; External Router: see page 17
•
Audio Control Panel Ordered Separately, Fader Bar Ordered Separately,
Optional Modules Ordered Separately; Platinum Router, CENTRIO, eBox: see page 18
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
11
Chapter 2: Installation
Scenario 1: All Components Ordered at the Same Time and
Preinstalled; Internal (NSM) Routers
Step Explained
1. Mount the control panel(s) into a desktop or a rack
2. Connect the control panel to another device
3. Install NEO frame into a rack
10. Customize push buttons on control panel
4. Configure NSM modules
9. Initialize IconMaster page 77
5. Attach breakout modules
8. Configure IconMaster control panel
6. Connect the NEO modules to another device
7. Check card-edge parameters are set to your preferences page 69 page 147 page 126
Scenario 2: All Components Ordered at the Same Time and
Preinstalled; External Router
Step Explained
1. Mount the control panel(s) into a desktop or a rack
2. Connect the control panel to another device
3. Install NEO frame into a rack
4. Mount external router into a rack
(see specific router manual)
5. Configure external router
Panacea
Platinum
6. Attach breakout modules
page 91 page 116
7. Connect the NEO modules to another device
8. Check card-edge parameters are set to your preferences page 69
9. Configure IconMaster control panel page 147
10. Initialize IconMaster page 126
11. Customize push buttons on control panel
12 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 2: Installation
Scenario 3: All Components Ordered at the Same Time and
Preinstalled; Platinum Router, CENTRIO. eBox
Step
1. Mount the control panel(s) into a desktop or a rack
2. Connect the control panel to another device
3. Install NEO frame into a rack
Explained
Mount Platinum router into a rack
(see Platinum Installation, Configuration, and
Operation Manual)
4. Configure eBox page 121
5. Configure Platinum page 121
6. Configure CENTRIO
11. Initialize IconMaster page 121
7. Attach breakout modules
10. Configure IconMaster control panel
8. Connect the NEO modules to another device
9. Check card-edge parameters are set to your preferences page 69 page 147 page 126
12. Customize push buttons on control panel
Scenario 4: Audio Control Panel Ordered Separately, All Other
Components Ordered at the Same Time and Preinstalled; Internal
(NSM) Routers
Step Explained
1. Connect main control panel to audio control panel
2. Mount the control panel(s) into a desktop or a rack
3. Connect the control panel to another device
4. Install NEO frame into a rack
11. Customize push buttons on control panel
5. Configure NSM modules
10. Initialize IconMaster page 77
6. Attach breakout modules
9. Configure IconMaster control panel
7. Connect the NEO modules to another device
8. Check card-edge parameters are set to your preferences page 69 page 147 page 126
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
13
Chapter 2: Installation
14
Scenario 5: Audio Control Panel Ordered Separately, All Other
Components Ordered at the Same Time and Preinstalled; External
Router
Step Explained
1. Connect main control panel to audio control panel
2. Mount the control panel(s) into a desktop or a rack
3. Connect the control panel to another device
4. Install NEO frame into a rack
5. Mount external router into a rack
(see specific router manual)
6. Configure external router
Panacea
Platinum
7. Attach breakout modules
page 91 page 116
8. Connect the NEO modules to another device
9. Check card-edge parameters are set to your preferences page 69
10. Configure IconMaster control panel page 147
11. Initialize IconMaster page 126
12. Customize push buttons on control panel
Scenario 6: Audio Control Panel Ordered Separately, All Other
Components Ordered at the Same Time and Preinstalled; Platinum
Router, CENTRIO, eBox
Step Explained
1. Connect main control panel to audio control panel
2. Mount the control panel(s) into a desktop or a rack
3. Connect the control panel to another device
7. Configure Platinum
4. Install NEO frame into a rack
6. Configure eBox
5. Mount Platinum router into a rack
(See Platinum Installation, Configuration,
and Operation Manual) page 121 page 121
8. Configure CENTRIO
13. Initialize IconMaster page 121
9. Attach breakout modules
12. Configure IconMaster control panel
10. Connect the NEO modules to another device
11. Check card-edge parameters are set to your preferences page 69 page 147 page 126
14. Customize push buttons on control panel
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 2: Installation
Scenario 7: Audio Control Panel Ordered Separately, Optional Modules
Ordered Separately; Internal (NSM) Routers Ordered Separately
Step Explained
1. Connect main control panel to audio control panel
2. Mount the control panel(s) into a desktop or a rack
3. Connect the control panel to another device
4. Install NEO options into NEO frame
5. Install NSM modules into NEO frame
6. Install NEO frame into a rack
13. Customize push buttons on control panel
7. Configure NSM modules
12. Configure IconMaster control panel page 77
8. Attach breakout modules
11. Initialize IconMaster
9. Connect the NEO modules to another device
10. Check card-edge parameters are set to your preferences page 69 page 126 page 147
Scenario 8: Audio Control Panel Ordered Separately, Optional Modules
Ordered Separately; Internal (NSM) Routers Preinstalled
Step Explained
1. Connect main control panel to audio control panel
2. Mount the control panel(s) into a desktop or a rack
3. Connect the control panel to another device
4. Install NEO options into NEO frame
5. Install NEO frame into a rack
12. Customize push buttons on control panel
6. Configure NSM modules
11. Initialize IconMaster page 77
7. Attach breakout modules
10. Configure IconMaster control panel
8. Connect the NEO modules to another device
9. Check card-edge parameters are set to your preferences page 69 page 147 page 126
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
15
Chapter 2: Installation
16
Scenario 9: Audio Control Panel Ordered Separately, Optional Modules
Ordered Separately; External Router
Step Explained
1. Connect main control panel to audio control panel
2. Mount the control panel(s) into a desktop or a rack
3. Connect the control panel to another device
4. Install NEO options into NEO frame
5. Install NEO frame into a rack
8. Attach breakout modules
6. Mount external router into a rack
(see specific router manual)
7. Configure external router
Panacea
Platinum page 91 page 116
9. Connect the NEO modules to another device
10. Check card-edge parameters are set to your preferences page 69
11. Initialize IconMaster page 126
12. Configure IconMaster control panel page 147
13. Customize push buttons on control panel
Scenario 10: Audio Control Panel Ordered Separately, Optional Modules
Ordered Separately; Platinum Router, CENTRIO, eBox
Step Explained
1. Connect main control panel to audio control panel
2. Mount the control panel(s) into a desktop or a rack
3. Connect the control panel to another device
4. Install NEO options into NEO frame
5. Install NEO frame into a rack
6. Install CENTRIO into Platinum router (see CENTRIO Installation,
Configuration, and Operation Manual)
7. Mount Platinum router into a rack (See Platinum Installation,
configuration, and Operation Manual)
8. Configure eBox page 121
9. Configure Platinum page 116
10. Configure CENTRIO page 121
11. Attach breakout modules
12. Connect the NEO modules to another device
13. Check card-edge parameters are set to your preferences page 69
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 2: Installation
Scenario 10: Audio Control Panel Ordered Separately, Optional Modules
Ordered Separately; Platinum Router, CENTRIO, eBox (Continued)
Explained Step
14. Initialize IconMaster
15. Configure IconMaster control panel
16. Customize push buttons on control panel page 126 page 147
Scenario 11: Audio Control Panel Ordered Separately, Fader Bar
Ordered Separately, Optional Modules Ordered Separately; Internal
(NSM) Routers Preinstalled
Step Explained
1. Install fader bar
2. Connect main control panel to audio control panel
3. Mount the control panel(s) into a desktop or a rack
4. Connect the control panel to another device
5. Install NEO options into NEO frame
6. Install NEO frame into a rack
13. Customize push buttons on control panel
7. Configure NSM modules
12. Configure IconMaster control panel page 77
8. Attach breakout modules
11. Initialize IconMaster
9. Connect the NEO modules to another device
10. Check card-edge parameters are set to your preferences page 69 page 126 page 147
Scenario 12: Audio Control Panel Ordered Separately, Fader Bar
Ordered Separately, Optional Modules Ordered Separately; External
Router
Step Explained
1. Install fader bar
2. Connect main control panel to audio control panel
3. Mount the control panel(s) into a desktop or a rack
4. Connect the control panel to another device
5. Install NEO options into NEO frame
6. Install NEO frame into a rack
7. Mount external router into a rack (see specific router manual)
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
17
Chapter 2: Installation
18
Scenario 12: Audio Control Panel Ordered Separately, Fader Bar
Ordered Separately, Optional Modules Ordered Separately; External
Router
Step
8. Configure external router
Panacea
Platinum
9. Attach breakout modules
Explained
page 91 page 116
12. Configure IconMaster control panel
10. Connect the NEO modules to another device
11. Check card-edge parameters are set to your preferences page 69 page 147
13. Initialize IconMaster page 126
14. Customize push buttons on control panel
Scenario 13: Audio Control Panel Ordered Separately, Fader Bar
Ordered Separately, Optional Modules Ordered Separately; Platinum
Router, CENTRIO, eBox
Step Explained
1. Install fader bar
2. Connect main control panel to audio control panel
3. Mount the control panel(s) into a desktop or a rack
4. Connect the control panel to another device
5. Install NEO options into NEO frame
10. Configure Platinum
6. Install NEO frame into a rack
9. Configure eBox
7. Install CENTRIO into Platinum router (see CENTRIO Installation,
Configuration, and Operation Manual)
8. Mount Platinum router into a rack
(See Platinum
Installation and
Operation
Manual) page 121 page 116
11. Configure CENTRIO
16. Initialize IconMaster page 121
12. Attach breakout modules
15. Configure IconMaster control panel
13. Connect the NEO modules to another device
14. Check card-edge parameters are set to your preferences page 69 page 147 page 126
17. Customize push buttons on control panel
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 2: Installation
Tools You’ll Need
The following is a list of tools and equipment you will need for a successful
IconMaster installation. (Your particular installation may or may not require all of these items, depending on which options you purchased.)
1. Desk or table with cutout; use the dimensions found on
OR
One standard 19-in. (0.4-m) rack and four to eight 40×1/4 flat-head screws
2. One medium Phillips screwdriver
3. For a direct setup (MKE-3901 directly to IconMaster control panel), one
36-in. (91-cm) crossover cable
4. For a network setup (IconMaster to Ethernet)
• 1 network hub, at least 10Base-T or 10/100Base-T
• Standard 10 Mbps 10Base-T Ethernet cable segments no longer than
382.08 ft (100 m) for IconMaster control panel, MKE-3901 module, and MGI-3903 module
5. RS-232 or TIA/EIA-422-B cable segment; no longer than 50 ft (15 m) for
RS-232, and 2,000 ft (610 m) for TIA/EIA-422-B, for use with external router or automation control device
6. NEO FR-3901, FR-3903, and FR-3923 Mounting Frames Installation and
Operation Manual
7. Internal routing device module, as appropriate (NEO NSM-7×2SHD or
NSM-7×2AES)
8. External routing device, as appropriate (Platinum, Panacea)
9. External routing device manual, as appropriate:
• (For use with NSM-7×2SHD internal routers) NEO
NSM-8×1SHD/NSM-7×2SHD SD/HD Wideband Video Routing
Switchers Installation and Operation Manual
• (For use with NSM-7×2AES internal routers) NEO
NSM-8×1EAS/NSM-7×2AES Serial Digital Audio Routing Switchers
Installation and Operation Manual
• (For use with Platinum 9RU, 15RU, and 28RU frames) Platinum Series
Frames and Modules Installation, Configuration, and Operation
Manual
• (For use with Panacea frames) Panacea Series Frame and Modules
Installation, Configuration, and Operation Manual
10. (For use with optional CENTRIO multiviewer) CENTRIO Multiviewer
Installation, Configuration, and Operation Manual and CENTRIO Layout
Designer User Guide
11. (For use with optional eBox) eBox Ethernet to Serial & GPI Interface Users
Manual
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
19
Chapter 2: Installation
Sample System Layout
shows a sample system layout that includes an external router, PC,
Ethernet switch, and IconMaster system. For illustrations of sample system
layouts for NEO routers, see “System Configurations—NEO Routers” on page
. For illustrations of sample system layouts for Panacea routers, see
Configurations—NEO Routers” on page 78
.
Primary inputs
Terminated
ENET
POWER
PS1
Station reference
SERIAL ALM/COM
XY
POWER
PS2
SYNC
1 3 5 7 9 11 13 15
2 4 6
INPUT
8 10 12 14 16
Genlock Outputs
1 3 5
Router outputs available for
Aux purposes
7 9 11 13 15
2 4 6
OUTPUT
8 10 12 14 16
Panacea 16x16 router
Inputs
Clean PGM PST Squeeze
Bkgd
Bus A Key 1 Fill 2
Ethernet 1
Ethernet 2
PGM
Output
Bus B Fill 1
Inputs
Key 2
Multi Function I /O
Ethernet switch
Video outputs
FX squeeze background
CG 1 CG 2 (Key 2)
PC with:
-Logo Creator
-Content Editor
-IconSet
-IconLogo Soft Panel
-IconMaster Configuration
-Utility
-CCS Navigator (optional)
IconMaster control panel
Figure 2-2. Sample System Layout
20 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 2: Installation
Installing Control Panels
Connecting the Main Panel and Optional Audio Panel
The IconMaster main control panel and audio control panel are connected to each other both mechanically (by means of a bracket) and electrically (by using two wiring harnesses). The audio control panel cannot operate independently of the main control panel, and must always be directly attached. If you ordered both controls at the same time, they will be preassembled at the factory.
If you ordered the control panels at different times you can connect them together yourself. To connect the main control panel and audio control panel together, follow these steps:
1. Remove the four screws on each side of the main control panel trim (see
).
Remove these four screws
Replace three screws for the new trim
Figure 2-3. Removal of Trim
2. Replace the side trim with the two new shorter pieces supplied. Only three screws are required on each side to attach the new trim.
3. Remove the cover plate from the back of the main control panel (see
).
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
21
Chapter 2: Installation
Remove cover plate
Figure 2-4. Removal of the Main Control Panel Cover Plate
4. Attach the audio control panel mounting bracket to the back of the main
control panel, using the screws provided (see Figure 2-5
).
22
Attach to the back of the main control panel
Figure 2-5. Audio Control Panel Mounting Bracket
5. Face the audio control panel down on top of the main control panel buttons.
Attach the two ribbon cables from the main control panel to the audio
).
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Audio control panel folded over top of the main control panel
Chapter 2: Installation
Base of main control panel
Ribbon cables
Figure 2-6. Ribbon Cable Between Main and Audio Control Panels
6. Attach the audio control panel to the mounting bracket by inserting the provided screws in the curved slots that overlap each side of the audio
).
Insert screw here
Insert screw here
Figure 2-7. Audio Control Panel Attachment
7. Set the audio control panel to the viewing angle that suits your needs, and then tighten the sliding screws.
Mounting the Control Panels
The two control panels of the IconMaster system are designed for desk and tabletop operation, or for use in a standard equipment rack. Desk and tabletop
mounting are described on page 24
; rack mounting is described on
.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
23
Chapter 2: Installation
Mounting Panels in a Desk or a Tabletop
The IconMaster control panels can be set into a desk or tabletop. (The optional audio control panel must be attached to the main control panel before you
mount it; see “Connecting the Main Panel and Optional Audio Panel” on page 21 .)
Note
The control panels are easier to see and use if the tabletop or desk is angled towards the operator. For illustration purposes here, the trim has been removed. In a typical desk or tabletop installation, the trim will remain attached.
Follow these steps to mount the control panels into a desk or tabletop:
1. Using the dimensions shown in Figure 2-8
(for the main control panel only) or
Figure 2-9 (for the main and audio control panels together), make a
cutout in the desk or tabletop.
2. Carefully place the control panels into the cutout.
10.1 inches
(25.7 cm)
16.75 inches (42.6 cm)
Figure 2-8. Desk or Tabletop Mount of Main Control Panel Alone
24 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 2: Installation
5
6
4
3
2
1
Figure 2-9. Desk or Tabletop Mount of Main and Audio Control Panels
5
6
3
4
1
2
Width of panel left to right
Length of panel front to back (total)
16.75 inches (42.6 cm)
13.9 inches (35.3cm)
Length of panel front to back (underside)
10.1 inches (25.7cm)
Length of audio panel overhang
Panel depth (front)
Panel depth (back)
3.8 inches (9.6cm)
3.5 inches (8.8 cm)
2.1 inches (5.2 cm)
Mounting Control Panels into a Rack
Note
The main and audio control panels can be mounted in a rack with or without the outer trim attached. However, the outer trim will use an additional 1RU of extra space above and below the unit if it is left attached. If you choose to remove the trim, ensure that you
replace the two middle screws found on each side (see Figure 2-3 on page 21
).
To install the main control panel and the optional audio control panel in a rack, use the adjustable left and right-side frame mounting brackets that are provided.
The brackets are designed so that you can angle the panels either upward or
downward, according to your needs. (See Figure 2-13 .) If you are using an
audio control panel, attach and connect the audio panel to the main control panel
frame before you attach the brackets (see “Connecting the Main Panel and
Optional Audio Panel” on page 21 ).
The following steps describe the installation of the control panels in a rack. If
you do not wish to remove the trim, start at step 6.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
25
Chapter 2: Installation
1. Remove the three or four screws on each side of the main control panel trim
(see
Remove these four screws
Figure 2-10. Removal of Trim for Rack Mounting
2. Remove the trim pieces from the sides of the main control panel.
3. Remove the wrist rest from the bottom of the main control panel.
4. Replace the middle two screws on each side of the main control panel with
4-40×1/4 FH screws (see Figure 2-11
).
26
4-40×1/4 FH screws
Figure 2-11. Main Control Panel Side Screws
5. If there is no audio control panel:
• Remove the trim from the top of the main control panel.
If there is an audio control panel: a.
Remove the three screws on each side of the audio control panel trim.
b. Remove the trim from the sides of the audio control panel.
c.
Remove the trim from the top of the audio control panel.
d. Replace the two screws on each side of the audio control panel with
4-40×1/4 FH screws (see Figure 2-12 ).
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 2: Installation
4-40×1/4
FH screws
Figure 2-12. Audio Control Panel Side Screws
6. Attach the mounting brackets to the sides of the main control panel using the screws provided (see
Attach 2 screws per side
Figure 2-13. Attaching the Rack-Mount Bracket
7. Loosen the screws on the sliders, and then reposition the sliders to change
the viewing angle of the control panels (see Figure 2-14
).
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
27
Chapter 2: Installation
Tighten screws at the back of the slider
Figure 2-14. Adjustment of Slider Screws
8. Tighten the slider screws and make all of the necessary cable connections on the back of the main control panel.
9. Align the control panel assembly so that the screw holes in the mounting brackets match up with those at the front of the rack.
10. Secure the control panel assembly to the rack with 10×32 machine-head mounting screws and washers.
11. Make necessary control panel connections (see
Connecting Main Control Panel Components
The IconMaster main control panel has external connections located in a bay on
the underside of the unit ( Figure 2-16 ). In addition, two 50-pin connectors at the
back of the panel provide an interface with the optional audio control panel.
28
Figure 2-15. Main Control Panel External Connections—Older Models
Figure 2-16. Main Control Panel External Connections—Newer Models
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 2: Installation
The Timecode IN provides a means for IconMaster to read a facility time-of-day real-time clock. If desired, feed a unity speed, forward counting LTC timecode signal into the Timecode IN connector, and configure the IconMaster to use the
RCP panel as it's primary time-of-day clock source. A Harris MTG-3901 module or CSD5300 product can be used for this timecode signal. DIP Switch
1 (below) is used to set the Timecode IN termination to either open or 600
Ω.
to setup IconMaster to use the RCP's Timecode IN as the real-time clock source.
Note
One RCP panel can be setup as the real-time clock source for multiple IconMaster channels.
The Timecode OUT connector is used to feed an external LTC timecode display device with a time function from the IconMaster. IconMaster can display either
the time-of-day or its segment timer on this output. See page 200
to set this up.
Figure 2-17. Timecode IN (Rear Panel View)
DIP Switch Settings
Figure 2-18. Timecode OUT (Rear Panel View)
The DIP switches on the main control panel allow you to set values for termination for timecode in (LTC) and for failsafe bootloader (CPU BOOT).
DIP switch 1 controls the LTC setting and DIP switch 2 controls the CPU
BOOT setting. See Figure 2-19 on page 30 for the values of these settings.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
29
Chapter 2: Installation
LTC
Open*
600
Ω
CPU BOOT
Normal*
Failsafe
* Default value
Figure 2-19. DIP Switch Setting Values
Power Supply
The IconMaster main control panel uses one external power supply. (For redundant power supply operation, two power supply units must be used.)
The DC output from one of the provided power supplies should be connected to
PS1 on the IconMaster control panel. Connect the second, redundant power supply to PS2.
When you plug in the power supply, the IconMaster control panel buttons will light up. You may want to verify the IP address and software version for your system. This function is performed via the Service menu (see the IconMaster
Function Operation and Configuration Manual for instructions).
NEO Modules Connection (Not Connected to a Network)
The IconMaster main control panel can be connected directly to the system’s
NEO frame-based modules when the system is not connected to a network. To do this, connect Ethernet on the main control panel to Ethernet 1 on the
MKE-3901 back module using a crossover (twisted) cable.
Network Connection
The IconMaster main control panel can be connected to a network system. To do this, connect Ethernet on the IconMaster main control panel (or Ethernet 2 on older panels) directly to a switch on the network using a straight cable.
30 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 2: Installation
Installing NEO Modules
Installing Standard NEO Modules (MKE-3901 and MGI-3903)
An IconMaster system includes an MKE-3901 mixer/keyer module and an
MGI-3903 IconLogo graphics module as standard equipment. These modules and their corresponding back connector modules are pre-installed at the manufacturing facility.
IconMaster LITE systems do not include the MGI-3903 IconLogo graphics module.
Changing MKE-3901 Front Module Jumpers Setting
Note
There are no jumpers on the MKA-3901 discrete audio module.
The MKE-3901 front module includes these jumpers. (
shows the different jumpers and their settings. Jumpers are preset to default
values at the manufacturing facility. Default values are indicated in Table 2-1 .)
•
J16: Reference input termination (see Figure 2-20 for the location)
•
J17 and J18: Serial E and Serial A port standards (see Figure 2-21 for the
location)
• J20 and J22: AES Audio-Over 1 and 2 (see
for the location)
•
J25 and J26: Serial Port A (RS-232-A) format (see Figure 2-22 for the
location)
To change the jumper settings, follow these steps:
1. Remove the MKE-3901 module from the NEO frame. (For instructions, see the NEO FR-3901, FR-3903, and FR-3923 Mounting Frames Installation
and Operation Manual).
2. Using a pair of tweezers or needle-nosed pliers, pull the jumper pack loose from its location.
3. Push the jumper pack onto the pins of the desired location.
4. Reinstall the MKE-3901 front module into the NEO frame.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
31
Chapter 2: Installation
Jumper J16
Jumper J22
Jumper J20
Figure 2-20. Jumpers for Reference Input and AES Audio-Over
Jumper J17 Jumper J18
Figure 2-21. Jumpers for Serial Port Standard
1
32
1. Jumper J17 on MKE-3901 must be set to same standard as jumper pack A2. Jumper J18 on
MKE-3901 must be set to same standard as jumper pack A1. For more information see
and
.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 2: Installation
Jumper J25
Jumper 26
Figure 2-22. Jumpers for Serial Port A Format
Note
Jumpers J20 and J22 on the MKE-3901 must be set to Balanced when the video breakout module is used.
Jumper J17 on the MKE-3901 must be set to the same standard
as jumper pack A2. For more information see Figure 2-34 on page 49
Jumper J18 on the MKE-3901 must be set to the same standard
as jumper pack A1. For more information see Figure 2-34 on page 49
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
33
Chapter 2: Installation
Table 2-1. Jumper Settings
Function
Reference input termination
Settings
Jumper 16
75
Ω impedance*
Hi-Z impedance
Serial port standard
Jumper 17/ Port E
Ext. Routing Control
Serial RS-232*
Jumper 18/Port B
Automation
Serial RS-232
Serial RS-422
Serial RS-422*
Audio-over impedance
Jumper 22
AES A/O 1 balanced*
Jumper 20
AES A/O 2 balanced*
34
AES A/O 1 unbalanced
AES A/O 2 unbalanced
Jumper 26
Serial port A
(RS-232 format)
Must always be set to 232
Jumper 25
232
* Default value
232
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 2: Installation
Installing Optional NEO Modules (MKE-3901-FX and
MKA-3901)
In addition to the standard NEO modules that come with your IconMaster system, you may purchase an MKE-3901-FX effects submodule and/or an
MKA-3901 balanced audio module.
Note
When purchased as a package, the MKE-3901 and the MKA-3901 are attached together using standoffs and screws.
If you ordered these optional modules at the same time as your IconMaster, the modules will be installed in the NEO frame at the manufacturing facility, and no further NEO module installation procedures are necessary. If you ordered these optional modules separately, you can install them yourself. For module installation instructions, see the NEO FR-3901, FR-3903, and FR-3923
Mounting Frames Installation and Operation Manual.
On one side, in this order:
• MKA-3901
• MKE-3901
• MGI-3903
Figure 2-23. MKA-3901, MKE-3901, and MGI-3903 Module Order
To function correctly, MKA-3901, MKE-3901, and MGI-3903 modules must be connected to one another before installation, and the modules must be mounted in
a specific order in a NEO frame. Figure 2-23 on page 35
shows the alignment of the modules;
Figure 2-24 on page 36 shows an exploded view. The MKA-3901
and MKE-3901-FX are attached to the MKE-3901 module.
• Top – MKA-3901 front module
1
• Middle – MKE-3901 front module
2
with optional MKE-3901-FX submodule
3
1. MKA-3901 modules do not require specific jumper settings.
2. MKE-3901 modules require specific jumper settings. See
for more information.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
35
Chapter 2: Installation
• Bottom – MGI-3903
36
.
Figure 2-24. Exploded View: MKA-3901 Front Module (Top) and
MKE-3901 Front Module with Optional MKE-3901-FX Submodule
(Middle), and MGI-3903 (Bottom)
3. MKE-3901-FX modules may be ordered and installed separately. See page 37 for more
information.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 2: Installation
Installing the Optional MKA-3901 Submodule
The MKA-3901 submodule can be ordered separately. (If you ordered this optional module at the same time as your IconMaster, it will be installed in the
NEO frame at the manufacturing facility, and no further NEO module installation procedures are necessary.) If you have ordered the module separately and need to install it in your IconMaster system, follow these steps:
1. Remove the MKE-3901 module from the NEO frame.
2. Fit the MKA-3901 module to the MKE-3901 module.
3. Secure using standoffs and retaining screws.
4. Reinstall the MKE-3901/MKA-3901 into the NEO frame, and then close the front panel.
Installing the Optional MKE-3901-FX Submodule
The MKE-3901-FX submodule can be ordered separately and added to an existing MKE-3901 module. (If you ordered this optional module at the same time as your IconMaster, it will be installed in the NEO frame at the manufacturing facility, and no further NEO module installation procedures are necessary.) If you have ordered the module separately and need to install it in your IconMaster system, follow these steps:
1. Remove the MKE-3901 module from the NEO frame.
2. If your system includes an MKA-3901 module, remove the four retaining screws from the MKA-3901 module, and then separate the MKA-3901 module from the MKE-3901.
Retain the screws.
3. Locate and fit the MKE-3901-FX module into the correct position on the
MKE-3901 module.
4. Install the submodule with the retaining screws included.
5. If applicable, fit the MKA-3901 module to the MKE-3901 module again.
6. Secure using standoffs and retaining screws.
7. Reinstall the MKE-3901 into the NEO frame, and then close the front panel.
Installing the NEO Frame into a Rack
For instructions about installing a NEO frame into a rack, see the FR-3901,
FR-3903, and FR-3923 Mounting Frames Installation and Operation Manual.
Your installation may also require breakout panel connections. See page 43 for
more information.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
37
Chapter 2: Installation
Connecting NEO Components
MKE-3901 Back Module Connections
shows the back module of the MKE-3901 module. Make all appropriate I/O connections as appropriate for your system setup. Specific information concerning Ethernet, Genlock, Bus A and B, and multifunction I/O connectors is provided below.
Genlock Outputs Inputs
Clean PGM PST
Squeeze
Bkgd
Bus A Key 1 Fill 2
Ethernet 1
Ethernet 2
Multi Function I/O
Figure 2-25. MKE-3901 Back Module
PGM
Output
Bus B Fill 1
Inputs
Key 2
Ethernet
Use Ethernet 1 to connect the MKE-3901 to a network hub or directly to an
IconMaster control panel.
Use Ethernet 2 to connect the MGI-3903 to a network hub or directly to an
IconLogo control panel.
Genlock
The default Genlock Source Type is Composite. To change this setting, see the
Genlock dialog box in the IconMaster configuration utility software.
This input is terminated to 75
Ω internally by default. See jumper J16 on page 34
if termination is not desired.
Multifunction I/O
The pin numbers for the Multi Function I/O connector, with corresponding pinout information, are shown in
Bus A/Bus B Input Connectors
For information about Bus A and Bus B connectors, see
Configurations—NEO Routers” on page 78 and “System
Configurations—NEO Routers” on page 78
.
38 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 2: Installation
Table 2-2. MKE-3901 Multi-Function I/O Pinouts
This pinout information is for use when it is necessary to wire directly to the connector. If you are using a ICONM-BO-V breakout module (shown in
Figure 2-27 on page 43 ), this information is not required.
21 20 19 18 17
16
15 14 13 12 11 10 9 8 7
6
5 4 3 2 1
42 41
62
40
61
60
39
38
59
37
58
57
36
56
35 34 33
55 54 53
32 31
52 51
30 29 28
50
49
48
27
26
25
47
46
45
24 23 22
44
43
Pin Function Pin Function Pin Function
9
10
11
12
13
14
7
8
5
6
3
4
1
2
15
16
MKE AES A/O 2 (B+)*
Ground
GPI 11
GPI 14
GPI 17
GPI 18
GPO 6
GPO 4
GPO 2
Bypass relay control
GPI 8
GPI 4
GPI 7
RS-232-B RxD or
RS-422-B RX -
RS-232-B n/c or
RS-422-B RX +
RS-232-E TxD or
RS-422-E TX -
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
MKE AES A/O 1 (B-)*
MKE AES A/O 2 (B-)*
Ground
GPI 12
GPI 13
GPI 16
GPO 11
GPO 7
GPO 5
GPO 3
GPO 1
GPI 6
GPI 2
GPI 5
GPI 3
GPI 1
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
MKE AES A/O 1 (B+)*
Ground
GPI 9
GPI 10
GPI 15
GPO 8
GPO 9
GPO 10
GPO 12
GPO 13
MGI LTC +
MGI LTC -
MGI temperature sensor +
MGI temperature sensor -
RS-232-D RxD
RS-232-D TxD
17
18
19
RS-232-E n/c or
RS-422-E TX +
RS-232-E n/c or
RS-422-E RX +
RS-232-E RxD or
RS-422-E RX -
RS-232-B TxD or
RS-422-B TX -
38
39
40
Ground
+5V**
Ground
59
60
61
RS-422-C TX -
RS-422-C TX +
RS-422-C RX +
20 41 RS-232-B n/c or
RS-422-B TX +
62 RS-422-C RX -
21 RS-232-A RxD 42 RS-232-A TxD
*Audio Over 1 and 2: For balanced data, use B+ and B-. For unbalanced (coax), use B+ for the signal and connect B- to ground (shield). There are also jumpers on the MKE card, which must be set to indicate balanced or coax.
**Reserved for bypass relay operation.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
39
Chapter 2: Installation
MKA-3901 Back Module Connections
shows the back module of the MKA-3901 module. Make all appropriate I/O connections as appropriate for your system setup.
• The pin numbers for the AES Input connector, with corresponding pinout
information, are shown in Table 2-3 on page 41
.
• The pin numbers for the AES Output connector, with corresponding pinout
information, are shown in Table 2-4 on page 42
.
Figure 2-26. MKA-3901 Back Module
40 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 2: Installation
Table 2-3. MKA-3901 AES Input Connector Pinouts
This information is for use when it is necessary to wire directly to the AES input connector. If you are using a
ICONM-BO-VAC or ICONM-BO-VAB breakout module, this information is not required.
21 20
42 41
19 18
40 39
17
16
38
15
37
36
14 13
35 34
12 11
33 32
10 9
31
30
8 7
29
28
6
27
5
26
4
25
3
24
2 1
23 22
62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43
Pin Function Pin Function Pin Function
13
14
15
16
9
10
11
12
7
8
5
6
3
4
1
2
Spare
Spare
Ground
Spare
Spare
Ground
AES BUS A 3 (B+)
AES BUS A 3 (B-)
Ground
AES BUS A 1 (B-)
AES BUS A 1 (B+)
Ground
AES BUS B 3 (B-)
AES BUS B 3 (B+)
Ground
AES BUS B 1 (B-)
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
Ground
N/C
Ground
Ground
Ground
Ground
Ground
Ground
Ground
Ground
Ground
Ground
Ground
Ground
Ground
Ground
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
AES BUS A 4 (B-)
AES BUS A 4 (B+)
Ground
AES BUS A 2 (B-)
AES BUS A 2 (B+)
Ground
AES BUS B 4 (B-)
AES BUS B 4 (B+)
Ground
AES BUS B 2 (B-)
AES BUS B 2 (B+)
Ground
Reserved for future use
Reserved for future use
Ground
Reserved for future use
17
18
19
20
AES BUS B 1 (B+)
Ground
Reserved for future use
Reserved for future use
38
39
40
41
Ground
Ground
Ground
Ground
59
60
61
62
Reserved for future use
Ground
Reserved for future use
Reserved for future use
21 Ground 42 Ground
For balanced data, use B+ and B-. For unbalanced (coax), use B+ for the signal and connect B- to ground (shield). To use the coax, the C version of the card must be purchased.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
41
Chapter 2: Installation
Table 2-4. MKA-3901 AES Output Connector Pinouts
This information is for use when it is necessary to wire directly to the AES output connector. If you are using the
ICONM-BO-VAC or ICONM-BO-VAB breakout module, this information is not required.
21 20 19 18
17 16 15
14 13
12
11
10
9 8 7
6
5 4 3 2 1
42 41 40 39
38
62
61
60
59
37
58
57
36
56
35 34
55 54
33 32
53 52
31 30 29 28
51 50
49
48
27
26
47
46
25 24
45
44
23 22
43
Pin Function Pin Function Pin Function
13
14
15
16
9
10
11
12
7
8
5
6
3
4
1
2
Reserved for future use
Reserved for future use
Ground
AES Pgm 3 (B+)
AES Pgm 3 (B-)
Ground
AES Pst 1 (B+)
AES Pst 1 (B-)
Ground
AES Pst 3 (B+)
AES Pst 3 (B-)
Ground
AES Clean 1 (B+)
AES Clean 1 (B-)
Ground
AES Mon 1 (B+)
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
Ground
N/C
Ground
Ground
AES Pgm 4 (B+)
AES Pgm 4 (B-)
Ground
AES Pgm 1 (B+)
AES Pgm 1 (B-)
Ground
AES Clean 2 (B+)
AES Clean 2 (B-)
Ground
AES Clean 3 (B+)
AES Clean 3 (B-)
Ground
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
Reserved for future use
Reserved for future use
Ground
AES Pgm 2 (B+)
AES Pgm 2 (B-)
Ground
AES Pst 2 (B+)
AES Pst 2 (B-)
Ground
AES Pst 4 (B+)
AES Pst 4 (B-)
Ground
AES Clean 4 (B+)
AES Clean 4 (B-)
Ground
AES Mon 2 (B+)
17
18
19
20
AES Mon 1 (B-)
Ground
AES Mon 3 (B+)
AES Mon 3 (B-)
38
39
40
41
Ground
Ground
Ground
Ground
59
60
61
62
AES Mon 2 (B-)
Ground
AES Mon 4 (B+)
AES Mon 4 (B-)
21 Ground 42 Ground
For balanced data, use B+ and B-. For unbalanced (coax), use B+ for the signal and connect B- to ground (shield). To use the coax, the C version of the card must be purchased.
42 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 2: Installation
Installing Breakout Modules
There are three breakout modules available in the IconMaster system. Table 2-5
shows the functionality of each of the breakout modules.
Table 2-5. Breakout Module Packages
Breakout Back Module
Name
Video Module
ICONM-BO-V video breakout
)
RS-232 and RS-422;
BNCs for audio over and video relay bypass
ICONM-BO-VAB balanced audio breakout module
)
RS-232 and RS-422;
BNCs for audio over and video relay bypass
ICONM-BO-VAC coaxial audio breakout module (see
RS-232 and RS-422;
BNCs for audio over and video relay bypass
Audio Module
Not applicable
Connecting Cables
• MKE breakout cable
(165-000242-00)
Screw terminals for discrete audio in and out
BNC connections for discrete audio in and out
• MKA breakout cable
(165-000243-00) x2
• MKE breakout cable
(165-000242-00)
• MKA breakout cable
(165-000243-00) x2
• MKE breakout cable
(165-000242-00)
ICONM-BO-V Video Breakout Module
Term.
P2
1
2
3
7
8
9
4
5
6
10
P3 P4 P5 P6
Figure 2-27. ICONM-BO-V Breakout Module
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
43
Chapter 2: Installation
) is the breakout module for the MKE-3901 video module. The module converts the 62-pin Multi Function I/O connector of the MKE-3901 to separate screw, BNC, and DB-9 connectors.
shows how the GPIs and GPOs (GPI outputs) are connected.
For information on the jumpers and jumper packs used on the ICONM-BO-V module, see
Screw Connectors
shows the screw-type connectors on the ICONM-BO-V breakout
module. Each row of screw terminals (P2 to P6) is described in Table 2-6 .
Table 2-6. ICONM-BO-V Screw Terminals
Terminal P2
7
8
5
6
3
4
1
2
9
10
GPI 8
GPI 7
GPI 6
GPI 5
GPI 4
GPI 3
GPI 2
GPI 1
GPO 7
GND
P3 P4 P5
MKE A/O 1 +
MKE A/O 1 -
GND
MKE A/O 2 +
GPO 6
GPO 5
GPO 4
GPO 3
GPI 17
GPI 18
GPO 8
GPO 9
MKE A/O 2 GPO 2
MGI TEMP SENS + GPO 1
GPO 10
GPO 11
MGI TEMP SENS Bypass relay control GPO 12
MGI LTC + +5 to MKE Relay GPO 13
MGI LTC-
GND
+5 to MKA Breakout -VE to MKE CTRL
+5 from MKE -VE to MKA CTRL
P6
GPI 9
GPI 10
GPI 11
GPI 12
GPI 13
GPI 14
GPI 15
GPI 16
GND
GND
Bypass Relay Control
• Connect P4, Pins 8, 9, and 10 together. This supplies the +5V from the
MKE-3901 module to the emergency relays on the video breakout module and the audio breakout modules.
• Connect P5, Pins 9 and 10 to P4, Pin 7.
• To externally control the bypass relays, disconnect P4, pin 7 from P5 pin 9 and P5 pin 10.
• To set bypass relays to BYPASS mode (emergency inputs routed to PGM outputs), leave P5 pin 9 and P5 pin 10 open (no connections).
• To set bypass relays to OPERATE mode (IconMaster PGM to PGM outputs), connect P5 pin 9 and P5 pin 10 to GND (P6 pin 9 or P6 pin 10).
44 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 2: Installation
GPI/GPO Connections
Internal External
+Vcc +5V
10k
100
External Internal
+5V
100
**Max Vcc is
+5V
“Open collector”
TTL compatible
GPO
Figure 2-28. GPI and GPO (GPI Out) Connections
GPI
TTL compatible
BNC Connectors
PGM Out A/O 1
RS232-A RS232/422-B
AES
ICONM-BO-V Video Breakout
Emerg In 1 A/O 2
RS232/422-C RS232-D
Figure 2-29. ICONM-BO-V BNC Connectors
RS232/422-E
Jumpers for AES Audio Over Impedance
The ICONM-BO-V video breakout module includes four jumpers (J1, J2, J3, and J4), which are used to set the impedance of AES Audio-Over 1 and
Audio-Over 2. The orientation of the jumper pins in
way you view them as you read the “J” labelling on the board.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
45
Chapter 2: Installation
Jumpers J1, J4, J2, and J3
46
Figure 2-30. Jumpers on ICONM-BO-V (for BNC Connectors)
To set the individual jumpers, follow these steps:
1. Move jumpers J1 and J4 to set the A/O 1 (top BNC connector) to either
Unbalanced or Balanced or (see
).
AES A/O 1 unbalanced AES A/O 1 balanced
J1 J4 J2 J3
J1 J4 J2 J3
Figure 2-31. A/O 1 Jumpers
2. Move Jumpers J2 and J3 to set A/O 2 (bottom BNC connector) to either
Unbalanced or Balanced or (see
).
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
AES A/O 2 unbalanced
Chapter 2: Installation
AES A/O 2 balanced
J1 J4 J2 J3
Figure 2-32. A/O 2 Jumpers
J1 J4 J2 J3
Bypass Relay Jumper (HD or Multiformat Operation)
For HD or multi-format operation, jumper J10 should be left in the default position, connecting pins 1 to 2. When a system is configured for SD, jumper
J10 should connect pins 2 to 3. See
for relay bypass jumper location and settings.
Default HD positiom
Program output
Program input
Jumper J10 Settings
HD (default)
Emergency input
SD
1
Figure 2-33. Relay Bypass Jumper J10
2 3
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
47
Chapter 2: Installation
DB-9 Connectors
Note
Jumpers J20 and J22 on the MKE-3901 must be set to Balanced when the video breakout module is used.
Jumper J17 on the MKE-3901 must be set to the same standard
as jumper pack A2. For more information see Figure 2-34 on page 49
Jumper J18 on the MKE-3901 must be set to the same standard
as jumper pack A1. For more information see Figure 2-34 on page 49
Table 2-7 on page 50 describes the pinouts for the DB-9 connectors, and
Table 2-8 on page 51 describes the use of the DB-9 serial connectors.
The ICONM-BO-V video breakout module includes two jumper packs (A1 and
A2), which are used for setting the serial port standard (RS-232 or RS-422). The orientation of the jumper pins in
and Figure 2-32 matches the way
you view them as you read the “J” labelling on the board.
To set the jumper packs, follow these steps:
1. Locate jumper packs A1 and A2 on the ICONM-BO-V module, as shown in
.
Figure 2-34 shows both serial ports in RS-422.
2. If necessary, extract the jumper packs, and then rotate them to match the
RS-232 or RS-422 setting as required. Figure 2-35 shows RS-232 and
RS-422 orientation.
48 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 2: Installation
Jumper packs A1 and A2
• Jumper J18 on MKE-3901 must be set to same standard as jumper pack A1
for serial port B.
• Jumper J17 on MKE-3901 must be set to same standard as jumper pack A2
for serial port E.
The settings shown at right are for RS-422 configuration. The orientation of the jumpers should be reversed for
RS-232, as below.
Figure 2-34. Jumper Packs on ICONM-BO-V (in RS-422 Mode)
Note
Each serial connector (RS-232 and RS-422) has the following settings:
• 38400 baud rate
• 8 data bits
• No parity
• 1 stop bit
• No flow control
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
49
Chapter 2: Installation
DB-9 (RS-232 and RS-422) Connectors
Table 2-7. ICONM-BO-V DB-9 Pinouts
PGM Out A/O 1
RS232-A RS232/422-B
AES
ICONM-BO-V Video Breakout
ICONM-BO-VAB Audio Balanced Breakout
Emerg In 1 A/O 2
RS232/422-C RS232-D RS232/422-E
Breakout
DB9 Pin
Port A
RS232
Port B, Port E
RS232 / RS422 Selectable
RS-232 Connection
RS-422
Connection
1
2
3
4
TxD
RxD
Frame Ground
RxD (Data received by
IconMaster)
TxD (Data sent by
IconMaster)
DTR (Data Terminal
Ready) *
Ground
Frame Ground
Ta Tx- (Data sent by
IconMaster)
Rb Rx+ (Data received by
IconMaster)
Rc (Receiver Common or
Shield)
Ground 5
6
GND
7
8
DSR (Data Serial Ready)
*
Tc (Transmit Common or
Shield)
RTS (Request to Send) ** Tb Tx+ (Data sent by
IconMaster)
CTS (Clear to Send) ** Ra Rx- (Data received by
IconMaster)
9 Frame Ground Frame Ground
* DB9 Pins 4 (DTR) and 6 (DSR) are connected internally to GND.
** DB9 Pins 7 (RTS) and 8 (CTS) are not used by IconMaster.
Port C
RS422
Frame Ground
Ta TxRxD
Rb Rx+
Tb Tx+
Ra Rx-
Frame Ground
Port D
RS232
TxD
GND
Note: RS-232 pinouts of port A are opposite to those of ports B, D, and E. The use of straight-through versus null-modem cables must be carefully considered.
50 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 2: Installation
shows default settings for the DB-9 connectors. These connector assignments can be changed via the ICU Serial Port Configuration dialog box.
For more information, see .
Table 2-8. DB-9 (RS-232 and RS-422) Connector Usage
Connector Use Baud Rate Notes
RS-232-A MKE-3901 machine control 38400
RS-232/422-B MKE-3901 automation control 38400
RS-232/422-C Reserved
RS-232-D MGI-3903 EAS
RS-232/422-E MKE-3901 external router control
38400
9600
38400
See
for more machine control information
Jumper J18 on the MKE-3901 must be set to the required standard and jumper pack A1 on the breakout module must be set to the same standard as
for more jumper information)
page 135 for more automation control information
Reserved for future use
Connect the EAS receiver for emergency notification messages
Jumper J17 on the MKE-3901 must be set to the required standard and jumper pack A2 on the breakout module must be set to the same standard as
for more jumper information)
Common DB-9 Cable Arrangements Examples
IconMaster
1
RxD 2
TxD 3
4
GND 5
6
7
8
9
Integrator/
Panacea
RS-232
1
2 RxD
3 TxD
4
5 GND
6
7
8
9
Figure 2-35. RS-232 IconMaster Port E to Integrator or Panacea Pin
Connections
Note
If re-assigned to port A, use a straight-through connection instead of this null-modem connection.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
51
Chapter 2: Installation
IconMaster
GND 1
TX- 2
RX+ 3
4
5
6
TX+ 7
RX- 8
9
Integrator /
Panacea RS-422
1 GND
2 TX-
3 RX+
4
5
6
7 TX+
8 RX-
9
Figure 2-36. RS-422 IconMaster Port E to Integrator or Panacea Pin
Connections
IconMaster
1
RxD
TxD
2
3
GND
6
7
4
5
8
9
PC 9-pin
RS-232 port
1
2
3
6
7
4
5
8
9
RxD
TxD
GND
Figure 2-37. RS-232 IconMaster Port B to Common PC Serial Port Pin
Connections
Note
If re-assigned to port A, use a straight-through connection instead of this null-modem connection.
52 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 2: Installation
IconMaster
1
TxD
RxD
GND
4
5
2
3
6
7
8
9
8
9
6
7
SPT
1
2
RxD
3
TxD
4
5
GND
Figure 2-38. RS-232 IconMaster Port A to SPT Pin Connections
Note
If re-assigned to port B or port E, use a null-modem connection instead of this straight-through connection.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
53
Chapter 2: Installation
ICONM-BO-VAB Balanced Audio Module
The ICONM-BO-VAB is a breakout module for the MKA-3901-B audio module. It also includes the video functionality of the ICONM-BO-V module.
The audio portion of the module converts the 62-pin AES Input and AES output connectors of the MKA-3901-B to screw terminal connections.
shows the screw-type connectors on the audio breakout module.
Each row of screw terminals (P4 to P15) is described in Table 2-9 .
Term.
1
2
3
4
5
6
7
8
P4 P5
P6
P7 Term.
P8
1
2
3
4
5
6
7
8
P9 P10 P11 Term.
P12 P13 P14 P15
1
2
3
4
5
6
7
8
Figure 2-39. ICONM-BO-VAB Breakout Module
Table 2-9. ICONM-BO-VAB Breakout Module Screw Terminals
7
8
5
6
3
4
1
2
Terminal
No.
Terminal Type/Function
P4 Inputs P5 Inputs
BUS B1 +
BUS B1 -
BUS B1 GND
BUS B3 +
BUS B3 -
BUS B3 GND
NC
NC
BUS A4 +
BUS A4 -
BUS A4 GND
BUS B2 +
BUS B2 -
BUS B4/B2 GND
BUS B4 +
BUS B4 -
P6 Inputs
BUS A1 +
BUS A1 -
BUS A1 GND
BUS A2 +
BUS A2 -
BUS A2/A3 GND
BUS A3 +
BUS A3 -
P7 Inputs
SPARE 1 +
SPARE 1 -
SPARE 1 GND
SPARE 2 +
SPARE 2 -
SPARE 2 GND
NC
NC
54 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 2: Installation
7
8
5
6
3
4
1
2
7
8
5
6
3
4
1
2
Table 2-9. ICONM-BO-VAB Breakout Module Screw Terminals (Continued)
Terminal
No.
Terminal Type/Function
P8 Outputs
MON 2 +
MON 2 -
MON 2 GND
MON 3 +
MON 3 -
MON 3/4 GND
MON 4 +
MON 4 -
P12 Inputs
NC
NC
EMER PGM 1 +
EMER PGM 1 -
EMER PGM GND
EMER PGM 2+
EMER PGM 2-
EMER PGM 2 GND
P9 Outputs P10 Outputs
CLEAN 3 +
CLEAN 3 -
CLEAN 3 GND
CLEAN 4 +
PST 4 +
PST 4 -
PST 4 GND
CLEAN 1 +
CLEAN 4 CLEAN 1 -
CLEAN 4/MON 1 GND CLEAN 1/2 GND
MON 1 +
MON 1 -
CLEAN 2 +
CLEAN 2 -
P13 Outputs P14 Outputs
PGM 1 +
PGM 1 GND
PGM 1 -
PGM 2+
PGM 2 GND
PGM 2 -
NC
NC
PGM 3 +
PGM 3 GND
PGM 3 -
PGM 4 +
PGM 4 GND
PGM 4 -
NC
NC
P11 Outputs
PST 1 +
PST 1 -
PST 1 GND
PST 2 +
PST 2 -
PST 2/3 GND
PST 3 +
PST 3 -
P15 Inputs
NC
NC
EMER PGM 3 +
EMER PGM 3 -
EMER PGM 3 GND
EMER PGM 4 +
EMER PGM 4 -
EMER PGM 4 GND
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
55
Chapter 2: Installation
ICONM-BO-VAC Coaxial Audio Module
The ICONM-BO-VAC is a breakout module for the MKA-3901-B audio module. It includes an ICONM-BO-V module with an audio portion. The audio portion of the module converts the 62-pin AES input and AES output connectors of the MKA-3901-B to coaxial connections. Each connector is
Figure 2-42 on page 57 shows the four BNC connectors on the audio breakout
module for connecting emergency inputs. From left to right, the connectors are for AES4 to AES 1.
Figure 2-40. ICONM-BO-VAC Breakout Module
AES
1 3 1 3 1 1 3 1 3 1 3 1 3
Bus A
In
Bus B
In
Spare
Clean
Out
Mon Out PST Out
PGM
Out
AES
2 4 2 4 2
Figure 2-41. Coaxial Connector Labels
2 4 2 4 2 4 2 4
56 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 2: Installation
Figure 2-42. Emergency BNC Audio Inputs (AES4 to AES 1, From Left to Right)
Video Relay Bypass Module
The video relay bypass is a separate module that is connected to the video breakout module.
Connections with ICONM-BO-V Module
When using the ICONM-BO-V module, connect PGM Output on the
MKE-3901-BM to PGM IN on the video relay bypass module using a coax cable, as shown in
.
Genlock Outputs Inputs
Clean PGM PST
Squeeze
Bkgd
Bus A Key 1 Fill 2
Ethernet 1
Ethernet 2
Multi Function I/O
PGM
Output
Bus B Fill 1
Inputs
Key 2
Figure 2-43. MKE-3901 Connections to the Video Relay Bypass Using the ICONM-BO-V
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
57
Chapter 2: Installation
Connections with ICONM-BO-VAB or ICONM-BO-VAC Module
When using the ICONM-BO-VAB or ICONM-BO-VAC module, connect PGM
Output on the MKE-3901-BM to the PGM IN on the Video Bypass module
using the provided coax cable, as shown in Figure 2-44
.
Genlock Outputs Inputs
Ethernet 1
Clean PGM PST
Squeeze
Bkgd
Bus A Key 1 Fill 2
Ethernet 2
Multi Function I/O
PGM
Output
Bus B Fill 1
Inputs
Key 2
Figure 2-44. MKE-3901 Connections to the Video Relay Bypass Using the ICONM-BO-VAB
58 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 2: Installation
Connecting Optional GPI Input and Output Devices
IconMaster frames are designed to work with JLCooper Electronics eBox Quad
Serial to Ethernet Interface. The eBox is a general puprpose interface box that converts serial communication ports, GPI inputs, and GPI outputs and outputs to 10/100BaseT Ethernet. Using eBox, you can control up to 66 GPI input and
61 GPI output devices. IconMaster communicates with eBox through the
IconMaster Ethernet connection.
Connecting the eBox to the IconMaster
1. Connect an Ethernet crossover cable between the Ethernet connector on a
PC to the Ethernet connector on the eBox. (If the PC is connected to a network, remove it from the network before connecting it to the eBox.)
2. Set the eBox DIP switch 8 to ON (to allow you to access the JLCooper web interface).
3. Access Network Connections from the Windows Control Panel box
(Start > Control Panel > Network Connections).
4. Select Local Area Network. The Local Area Network Connections box will appear.
5. Select TCP/IP as the Internet procotol. The Internet Protocol (TCP/IP)
Properties box will appear. Use the following IP addresses:
• IP address: 192.168.254.100
• Subnet mask: 255.255.255.0
• Default gateway: IP address: 192.168.254.102
6.
Using Microsoft Internet Explorer 6 as your web browser, access the
JLCooper electronics eBox configuration web page, and then configure the eBox to Server mode, as described in the eBox Ethernet to Serial & GPI
Interface Users Manual.See Table 2-10
for settings information .
Note
Internet Explorer 6 is the only web browser that can be used to configure and program the eBox.
Table 2-10. eBox to IconMaster Configuration Settings
Configuration Item
Primary Setup Information
Device IP Address
Subnet Mask
Gateway Address
Port number
Setting
Site-specific
Site-specific
Site-specific
5003
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
59
Chapter 2: Installation
60
Table 2-10. eBox to IconMaster Configuration Settings (Continued)
Configuration Item Setting
Primary Setup Information
Client Mode Ony Information - Not Used
Password Protection - Not Used
Serial Port Setup Parameters
Baud Rate (Serial 1-4)
Parity (Serial 1-4)
38400
On
Parity Type (serial 1-4)
Serial Time Out
Maximum Buffer Size
Even
Per default
Per default
7. Turn DIP switch 8 to OFF, and then unplug the Ethernet connection between the PC and the eBox. If necessary, reconnect the reconnect the PC to its network.
8. Move the eBox to its final destination, and then connect the eBox to the
Ethernet network.
9. Make all other desired GPI/GPO and serial connections to the eBox connections.
Note
The eBox needs to be properly grounded to ensure proper operation of the GPI and GPO.
10. Set the buttons on the back of the eBox to the correct RS-232 or RS-422 position, and set Host mode or Machine mode (this sets the states of pins 2 and 3 for TX and RX).
Note
DIP switches 1, 2, and 3 must be set to ON and DIP switch 7 must be set to OFF for the eBox to run in the web page-defined IP address mode.
11. Using the IconMaster Configuration Utility (ICU), configure the eBox settings as applicable, in this order:
• Enable External I/O Module (
• External Interface connections (
•
Machine control, GPI/GPO ( page 177
,
• Serial tally to tally system (
•
)
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 2: Installation
Figure 2-45.
JLCooper EBox Settings for IconMaster
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
61
Chapter 2: Installation
Customizing Pushbuttons
The IconMaster control panel uses pushbuttons that you can customize. To customize a pushbutton, follow these steps:
1. Remove the lens assembly by grasping the switch tightly and pulling the lens off the switch.
Once the lens assembly is released from the switch, the lens and pushbutton can be separated.
2. Remove the appropriate text film from the “Optional Control Panel Labels” plastic sheet included in this manual.
3. Separate the lens and the pushbutton and then place the text film inside the lens cap.
4. After aligning the notches in the lens with the tabs in the pushbutton, join the pieces together.
5. Firmly press the lens assembly onto the plunger by applying pressure from the top to the bottom until both are snapped together.
62
Figure 2-46. Removable Parts of a Pushbutton
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 2: Installation
Installing an Optional Fader Bar
When installed as an upgrade, the IconMaster fader bar must be inserted and mounted from underneath the main control panel after the existing front plastic bezel is removed. There are three general stages to the installation: removing the bezel, installing the fader bar assembly, and assembling the handle.
Disassembling the IconMaster
1. Disconnect the power supply.
2. Disconnect the Ethernet and serial connections from the IconMaster control panel as necessary.
3. If necessary, remove the IconMaster control panel from its desktop/tabletop location from its mounting rack.
Removing the Bezel
1. Turn the main control panel over on its face.
2. In the connector bay on the left side, remove the four screws that hold the fader bar access cover in place (see
Remove the four screws holding the access cover in place.
Figure 2-47. Removal of Access Cover
3. Inside the panel (as shown in Figure 2-48 on page 64 ), remove the two
screws that secure the existing plastic bezel, retaining the screws for future use.
4. Turn the panel over, and then lift off the existing plastic bezel.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
63
Chapter 2: Installation
Installing the Fader Bar Assembly
1. On the front of the panel, position the new fader bar bezel over the fader bar slot, ensuring that you align the two square holes with the up and down arrow LEDs.
2. Turn the panel back over to reveal its underside, and then, using the original bezel screws, secure the new fader bar bezel (see
).
CAUTION
Do not overtighten the fader bar mounting screws. A snug fit is sufficient.
Bezel screws
Standoffs for mounting fader bar assembly
64
Plastic power supply connector
Figure 2-48. Securing the New Bezel
3. Slide the fader bar arm through the slot, so that the assembly fits over the two standoffs (see
).
4. Mount the fader bar assembly onto the standoffs using the two provided screws.
Ensure the connector cable side of the fader bar assembly is facing the shallow end of the control panel (nearest to the plastic power supply connector).
5. Remove the jumper located on the header next to the fader bar assembly.
6. Attach the fader cable to the header connector.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 2: Installation
7. Reinstall the access cover, being careful to avoid pinching the cable.
CAUTION
The locking cable connector will only fit one way. Do not force the connector if it does not snap into place easily.
Front of main control panel
Plastic power supply connectors
Wires facing front of main control panel
Jumper removed;
3-pin connector attached
Fader bar assembly installed
Rear of main control panel
(next to Audio Control Panel)
Figure 2-49. Fader Bar Installation and Connection
Assembling the Handle
1. Turn the control panel right side up.
2. Align the two opposing caps of the handle on the fader bar arm, and then insert the provided screw and nut.
3. Tighten the screw, and then snap on the two end caps.
4. Reinstall the IconMaster control panel into its desktop/tabletop or mounting rack location.
5. Reconnect any Ethernet and/or serial connectors.
6. Reconnect the power supply.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
65
Chapter 2: Installation
66 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 3
Module Configuration
Overview
This chapter describes the configuration and use of the MKE-3901, MKA-3901, and MGI-3903 modules in the IconMaster system.
The following topics are covered:
•
“Operator, All, and Setup Parameter Lists” on page 69
•
“LEDs and Module Indicators” on page 73
This chapter presupposes that you have a working knowledge of NEO card-edge configuration and have used it with other NEO modules. If not, please refer to the NEO FR-3901, FR-3903, and FR-3923 Mounting Frames
Installation and Operation Manual and familiarize yourself with card-edge operation before you continue the configuration process.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
67
Chapter 3: Module Configuration
Navigating the MKE-3901 Operator and All Lists
To navigate, and then view or change a parameter from the Operator and All
Lists, follow these steps:
1. Open the front panel of the NEO frame.
2. Press any card-edge control to turn on the VFD screen.
The message MKE3901 appears. If a previous user has left the display at a different parameter name, repeatedly press the Escape button until the message MKE3901 appears.
After several seconds of inactivity, a scrolling message will appear, describing the purpose of the currently selected parameter.
3. Push the Enter button.
The name of the first parameter option in the list appears.
4. Push the Enter button again to access the options for the parameter displayed on the VFD screen.
OR
Press the Nav+/Nav- switch down repeatedly to view other parameters, and then press Enter to access an item’s parameter options.
5. Press the Nav+/Nav- switch up or down to scroll through the different selectable parameter options, and then press Enter to select the value you want.
OR
Press the Nav+/Nav- switch up or down to adjust the numeric parameter value, and then press Enter.
6. Close the front panel of the frame to ensure the cooling system continues to operate properly.
68 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 3: Module Configuration
Operator, All, and Setup Parameter Lists
The MKE-3901 displays its parameters in an Operator List, All List, and Tree
View. These parameters are visible at the card-edge of the module and in CCS software.
These lists include the following parameters:
Operator and All Lists
Items in gray are in the All List only.
Table 3-1. MKE-3901 Operator and All Lists
Card-Edge ID Parameter Name
Unit_Name
SW_Version
IP_Address
Unit Name
Software Version
IP address
Function User Range
Displays the name of the device
Displays the version number of the currently installed software
Changes the address of the
IconMaster module on the network.
String (MKE3901)
String (none)
String (192.168.100.252)
SubnetMask
Gateway
OperStd
Lite_Mode
AutoHold
PgmBypass
PST_Src
PGM_Src
Subnet Mask
Gateway
Operation Standard
Lite Mode
Automation Hold
Program Bypass
PST Source Selection
PGM Source Selection
Changing the IP address releases the
IconMaster from panel control. To regain control of the panel, enter the new IP address into the panel's list of
“reachable” machines
Changes the range of IP addresses that can communicate with this device
String (255.255.0.0)
Changes the network routing for the device
String (0.0.0.0)
String (None)
String (No) Indicates whether the device is operating as a lite version of
IconMaster; some features are disabled in this mode
Stops the IconMaster from responding to Automation commands
When activated, bypasses the program bus
• On
• Off
• On
• Off
Selects the source for preset bus
Selects the source for the program bus
String (None)
String (None)
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
69
Chapter 3: Module Configuration
Key1_OnNext
Key2_OnNext
Key3_OnNext
Key4_OnNext
Key5_OnNext
Key6_OnNext
Key1_OnAir
Key2_OnAir
Key3_OnAir
Key4_OnAir
Key5_OnAir
Key6_OnAir
AO1_OnNext
AO2_OnNext
Table 3-1. MKE-3901 Operator and All Lists (Continued)
Card-Edge ID Parameter Name
BKGD BKGD
TAKE
PREROLL
TransSpeed
TransShape
ATransShape
TAKE
PREROLL
Transition Speed
Transition Shape
Audio Trans Shape
BreakawayMode Breakaway Mode
Function
Activates the BKGD function, so that a background transition from the
PST bus to the PGM bus will occur when you select Take or Preroll
Triggers a take, causing the next transition to start immediately
Triggers a preroll, activating a different piece of equipment to perform an event
Sets the transition rate
Selects the type of transition that will be performed
Selects the type of audio transition that will be performed
When off, the audio and video transition at the same time; when this parameter is set to one of the other options, only that option will transition
Triggers the specified key on the next transition
User Range
• On
• Off
• On
• Off
• On
• Off
String (None)
• Cut-Fade
• Fade-Cut
• Fade-Fade
• X-Fade
• Cut-Fade
• Fade-Cut
• Fade-Fade
• X-Fade
• Off
• Video
• Audio
• On
• Off
Key1 On Next Trans
Key2 On Next Trans
Key3 On Next Trans
Key4 On Next Trans
Key5 On Next Trans
Key6 On Next Trans
Key1 On Air
Key2 On Air
Key3 On Air
Key4 On Air
Key5 On Air
Key6 On Air
AO1 On Next Trans
AO2 On Next Trans
Triggers the specified key to air immediately
• On
• Off
Triggers the specified audio over on the next transition
• On
• Off
70 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 3: Module Configuration
Table 3-1. MKE-3901 Operator and All Lists (Continued)
Card-Edge ID
AO1_OnAir
AO2_OnAir
K3_LogoSel
K4_LogoSel
K5_LogoSel
K6_LogoSel
FTB
SIL
S_PST_Present
S_PGM_Present
S_K1_Present
S_K1_NonSync
S_K2_Present
S_K2_NonSync
S_REF_Present
S_HW_Error
Parameter Name
AO1 On Air
AO2 On Air
Assign Logo to Key3
Assign Logo to Key4
Assign Logo to Key5
Assign Logo to Key6
Fade To Black
Silence
PST Present Status
S_PST_NonSync PST NonSync Status
PGM Present Status
S_PGM_NonSync PGM NonSync Status
Key1 Present Status
Key1 NonSync Status
Key2 Present Status
Key2 NonSync Status
Reference Present
Hardware Error
S_COMM_Error Communication Error
Function
Triggers the specified audio over to air immediately
User Range
• On
• Off
Selects the logo for the specified key String (None)
Causes the video program outputs to immediately fade to black
• On
• Off
Causes the audio program outputs to immediately fade to silence
• On
• Off
Indicates whether there is data on the
Preset bus
• Yes
• No
Indicates whether the Preset bus is synced correctly
Indicates whether there is data on the
Program bus
• Yes
• No
• Yes
• No
Indicates whether the Program bus is synced correctly
• Yes
• No
Indicates whether the specified key has been assigned
Indicates whether the specified key is synced correctly
• Yes
• No
• Yes
• No
Indicates whether the specified key has been assigned
Indicates whether the specified key is synced correctly
• Yes
• No
• Yes
• No
Indicates whether reference signal is present
• Yes
• No
Indicates a detected hardware malfunction
Indicates a detected communication error
• Yes
• No
• Yes
• No
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
71
Chapter 3: Module Configuration
Table 3-1. MKE-3901 Operator and All Lists (Continued)
Card-Edge ID Parameter Name
S_Warning_Msg System Warning Msg
Function
Indicates that the system has triggered a warning message
BreakawayStatus Breakaway Status
Sw_Ver Software Version
Displays whether breakaway status is active
Displays the current software version number
User Range
• Yes
• No
• Yes
• No
0.0 to 9.999 (clip)
3200
Setup Parameters
You can modify the SETUP parameters to configure the card-edge controls for your personal needs. The structure of the Setup menu is as follows (default settings are indicated by asterisks):
Nav Mode (Navigation Mode)
(Options: Oper List*, All List, Tree View)
SelPar Adj Mode (Selectable Parameter Adjust Mode)
(Options: Immediate, Delayed*)
Brws Mode (Browse Mode)
(Options: Param List, Param+Val*)
Scrl Mode (Scroll Mode)
(Options: Wrap*, Don’t Wrap)
Disp Inten (Display Intensity)
(Options: 100%, 50%*, 25%, 12%)
Param Desc (Parameter Description)
(Options: Disabled, Enabled*)
About
[RO]
See your NEO FR-3901, FR-3903, and FR-3923 Mounting Frames Installation
and Operation Manual for more information on Setup items.
72 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 3: Module Configuration
LEDs and Module Indicators
MKE-3901 LEDs and Module Indicators
Each MKE-3901 module has 8 card-edge LEDs and 4 module indicators. The module indicators include Major Alarm and Minor Alarm. These alarms are not currently in use in the IconMaster system.
illustrates the locations of the LEDs and standard module indicators on the MKE-3901 module. The meanings of the LEDs are described in
. The meanings of the module indicators are described in
.
Standard module indicators Local/Remote switch
LEDs
SW1
Nav +
Nav -
Enter
Esc
Major
Alarm
Minor
Alarm Power
Module
Status
Escape button
Major alarm
Power
Nav+/Nav- switch
(up/down)
Enter button
Minor alarm
Module status
Card extractor
Figure 3-1. MKE-3901Card-Edge LEDs and Module Indicators
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
73
Chapter 3: Module Configuration
D5
D6
D7
D8
Table 3-2. MKE-3901 LED Descriptions
LED Number
D1
LED
Name
Lock
Color Meaning (When Lit)
D2
D3
D4
AO 1
AO 2
BCG Mix
Key 1
Key 2
Key/MGI
FTB/FTS
Green The module is locked to the reference signal.
Green The Audio Over 1 function is on air.
Green The Audio Over 2 function is on air.
Green A video background transition is in progress.
Green Key 1 is on air.
Green Key 2 is on air.
Green Key 3, 4, 5, or 6 is on air.
Green Video is black or audio is silent.
Table 3-3. MKE-3901 Module Indicator Descriptions
Module
Indicator
Color Meaning (When Lit)
Major Alarm
Minor Alarm
Power
Module Status
Red
Yellow
Green
Green
(Not currently active)
(Not currently active)
The module is receiving power.
The module is configured, loaded, and operational.
74 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 3: Module Configuration
MGI-3903 LEDs and Module Indicators
The IconMaster logo inserter has 2 card-edge LEDs and 4 standard module indicators.
CAUTION
Never remove the compact flash card when the Compact
Flash Card Active LED is on or flashing. Doing so may corrupt the files on the card.
The module generates visible alarm signals to alert users of failures or impending failures. These alarm signals can be found in the following locations:
• As red or yellow LEDs on the front module card-edge
• As red or yellow LEDs on the 3901AIC Alarm Interconnect Module or the
3901RES-E Resource Module (visible via light pipes through the NEO frame’s front panel)
• As part of a list of activated alarms found in the MGI-3903 Setup menu
Figure 3-2 on page 75 illustrates the locations of the LEDs and standard module
indicators on the MKE-3901 module. The meanings of the LEDs are described
in Table 3-4 on page 76 . The meanings of the module indicators are described in
.
Standard module indicators Local/Remote switch
SW1
Nav +
Nav -
Enter
Esc
Major
Alarm
Minor
Alarm Power
Module
Status
LEDs
Ejector
Compact flash card socket
Escape button
Major alarm
Power
Nav+/Nav- switch
(up/down)
Enter button
Minor alarm
Module status
Card extractor
Figure 3-2. MGI-3903 Card-Edge LEDs and Module Indicators
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
75
Chapter 3: Module Configuration
Table 3-4. MGI-3903 LED Descriptions
LED Indicator Color Meaning (When Lit)
ACT
(Compact flash card active)
MTD
(Compact flash card mounted)
Amber The flash card is actively being written to or read from. To prevent corruption of the data, do not remove the flash card when this LED is lit.
Green The flash card has been opened and the files recognized by the MGI-3903
Note
A frame’s active resource module provides additional LEDs that indicate conditions not included in these module-specific LEDs.
See the card-edge of the resource module for these LEDs.
Table 3-5. MGI-3903 Module Indicator Descriptions
LED Indicator
Major Alarm
Minor Alarm
Power
Module Status
Color Meaning (When Lit)
Red There is a problem with the card that will stop the product functioning correctly
Amber There is a minor problem with the card that may reduce the functionality of the product
Green
Green
The card is receiving power
The module is configured, loaded and operating correctly
76 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 4
Router Connections
Sample System Layout
Primary inputs
Terminated
ENET
POWER
PS1
Station reference
SERIAL ALM/COM
XY
POWER
PS2
SYNC
1 3 5 7 9 11 13 15
2 4 6
INPUT
8 10 12 14 16
Genlock Outputs
1 3 5
Router outputs available for
Aux purposes
7 9 11 13 15
2 4 6
OUTPUT
8 10 12 14 16
Panacea 16x16 router
Inputs
Clean PGM PST
Squeeze
Bkgd
Bus A Key 1 Fill 2
Ethernet 1
PGM
Output
Bus B Fill 1
Inputs
Key 2
Ethernet 2
Multi Function I /O
Ethernet switch
Video outputs FX squeeze background
CG 1 CG 2 (Key 2)
PC with:
-Logo Creator
-Content Editor
-IconSet
-IconLogo Soft Panel
-IconMaster Configuration
-Utility
-CCS Navigator (optional)
IconMaster control panel
Figure 4-1. Sample System Layout Including a Router, PC, Ethernet Switch and IconMaster System
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
77
Chapter 4: Router Connections
System Configurations—NEO Routers
Note
System configurations for Panacea routers start on
System configurations for Platinum routers start on
This section describes the connections that are required in some typical configurations involving NEO NSM internal routers. The following NEO router configurations are described in this section:
• IconMaster System with Internal Video NSM Router and Optional
ICONM-BO-V Module
• IconMaster System with Single Channel Audio and Video NSM Routers and Optional ICONM-BO-VAC Module
• IconMaster System with Internal (Two Channel) Audio and Video NSM
Routers and Optional ICONM-BO-VAC Module
General Information
Both Video and Audio NSMs
• Only one set of NSMs can be installed in a 3RU frame.
• The source offset for all NSM modules is 1.
• The destination offset for all NSM modules is 0.
Video-Only NSM Modules
• The first video NSM module must be assigned an X-Y level of 0.
• When ganging 2 cards together, the second module must be assigned an
X-Y level of 1.
Audio-Only NSM Modules
• The NSM-7×2AES router supports a single AES stream for both A and B inputs on the IconMaster. If the NSM-7×2AES routers are to be used for discrete AES audio for a full two AES (four-channel) system, four of these router modules are required.
• The expected use would be as follows:
• NSM #1 and NSM #2 provide AES 1 for Bus A and Bus B.
• NSM #3 and NSM #4 provide AES 2 for Bus A and Bus B.
78 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 4: Router Connections
Sample Configuration 1: IconMaster System with Internal
Video NSM Router and Optional ICONM-BO-V Module
This section describes the connections that are required in a typical configurations involving an IconMaster system with an NSM video router module and an optional breakout module. You can place the NSM modules
1. Configure the NEO NSM Module
1. Set the NEO NSM back module to Unterminated reference: a.
Remove the NSM back module from the NEO frame.
b. Locate jumper JP1 on the NEO NSM back module (see
and then set the NEO NSM back module to Unterminated reference by setting JP1 as shown. c.
Reinstall the NSM back module into the NEO frame.
Jumper JP1 set to
Unterminated
Figure 4-2. Jumper JP1 on the NSM Back Module
2. Connect a maximum of 7 video inputs to the BNC connections labeled In 1 to In 7.
3. Connect Out 1 on the NSM to Input Bus A on the MKE-3901.
4. When using the ICONM-BO-VAC breakout module and NSM routers, audio output 1 from the NSM router must be connected to Bus A In 1 on the breakout module as indicated in
.
When using the ICON-BO-VAB breakout module and NSM routers, the audio output 1 from the NSM router must be connected to Input Bus A1 on the breakout module as indicated in Table 2-9 on page 54 .
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
79
Chapter 4: Router Connections
Figure 4-3. IconMaster System with Internal Video NSM Router and Optional ICONM-BO-V Module
80 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 4: Router Connections
Bus A In 1
Figure 4-4. Audio 1 NSM Connection to ICONM-BO-VAC
2. Make Additional Connections
1. Connect your composite station reference to the Ref Inputs and Genlock
connection as shown in Figure 4-3 .
2. On the MKE-3901 back module, connect Key 1 input source to Key 1 and
Fill 1 as appropriate.
3. On the MKE-3901 back module, connect Key 2 input source to Key 2 and
Fill 2 as appropriate.
On the MKE-3901 back module, Squeeze Bkgd can be supplied by an external router.
Note
The IconMaster control panel can be connected to any network switch that shares a network with the MKE-3901 and MGI-3903 modules.
4. Connect the two Ethernet ports as follows:
Connect Ethernet 1 (connection for MKE-3901 control) to a switch using a straight-through Ethernet cable.
Connect Ethernet 2 (two connection options for MGI-3903 control and logo download)
• To the same switch as Ethernet 1 using a normal Ethernet cable
• To a dedicated switch used for the MGI functionality using a normal
Ethernet cable
5. Power up the system.
3. Set the IP Address for the MKE-3901 and MGI-3903 Modules
See
“Configuring IP Addresses” on page 119
for more information.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
81
Chapter 4: Router Connections
4. Set the NSM Card-Edge Parameters
Note
See the Installation and Operation Manual for your NEO module for more detailed information about setting parameters.
1. Press the left (Esc) button until the NSM message appears on the VFD display
2. Press the right (Sel) button.
3. Use the toggle switch (Nav) to scroll through the parameter list until Setup is highlighted.
4. Press the right (Sel) button.
5. Use the toggle switch (Nav) to scroll through the parameter list until Nav
Mode is highlighted.
6. Press the right (Sel) button.
7. Use the toggle switch (Nav) to scroll through the parameter list until All
List is highlighted.
8. Press the right (Sel) button.
9. Press the left (Esc) button.
10. Press the left (Esc) button again.
11. Use the toggle switch (Nav) to scroll through the parameter list until XY
Level is highlighted.
12. Press the right (Sel) button.
13. Use the toggle switch (Nav) to scroll through the values until 0 (on the first
NSM) or 1 (on the second NSM) is reached.
14. Press the left (Esc) button to set the value.
15. Use the toggle switch (Nav) to scroll through the parameter list until
SrcOffset is highlighted.
16. Press the right (Sel) button.
17. Use the toggle switch (Nav) to scroll through the values until 1 is reached.
18. Press the left (Esc) button to set the value.
19. Use the toggle switch (Nav) to scroll through the parameter list until
DestOffset is highlighted.
20. Press the right (Sel) button.
21. Use the toggle switch (Nav) to scroll through the values until 0 is reached.
22. Press the left (Esc) button to set the value.
82 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 4: Router Connections
Sample Configuration 2: IconMaster System with Single
Channel Audio and Video NSM Routers and Optional
ICONM-BO-VAC Module
This section describes the connections that are required in a typical configurations involving an IconMaster system, with single channel audio and video NSM router modules and an optional breakout module. You can place the
NSM modules anywhere in the same NEO frame as the IconMaster system.
Figure 4-6 on page 84 shows a detailed illustration of this process.
1. Configure the NSM Modules
Note
The first NSM module will provide Inputs 1 to 5; the second NSM module will provide Inputs 6 to 12.
1. Set the NEO NSM back module to Unterminated reference: a.
Remove the NSM back module from the NEO Frame.
b. Locate jumper J11 on the NEO NSM back module (see
c.
Set the NEO NSM back module to Unterminated reference by setting
J11 as shown. d. Reinstall the NSM back module into the NEO frame.
Jumper JP1 set to
Unterminated
Figure 4-5. Jumper J11 on the NSM Back Module
2. On the first NSM back module, connect a maximum of 5 audio inputs to the
BNC connections labeled In 1 to In 5.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
83
Chapter 4: Router Connections
Figure 4-6. IconMaster System with Internal (Single Channel) Audio and Video NSM Internal
Routers and Optional ICONM-BO-VAC Module
84 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 4: Router Connections
3. On the second NSM back module, connect a maximum of 7 video audio inputs to the BNC connections labeled In 1 to In 7.
4. Connect Out 1 on the first NSM to AES Bus A on the MKA-3901. This can be done by direct connection, or by ICONM-BO-VAB or
ICONM-BO-VAC breakout module connection.
5. Connect Out 2 on the first NSM to AES Bus B on the MKA-3901.
6. Connect Out 1 on the second NSM to In 6 on the first NSM.
7. Connect Out 2 on the second NSM to In 7 on the first NSM.
2. Make Additional Connections
1. Connect your composite station reference to the Ref Inputs and Genlock
connection as shown in Figure 4-6 .
2. On the MKE-3901 back module, connect Key 1 input source to Key 1 and
Fill 1 as appropriate.
3. On the MKE-3901 back module, connect Key 2 input source to Key 2 and
Fill 2 as appropriate.
4. On the MKE-3901 back module, Squeeze Bkgd can be supplied by an external router.
Note
If you are connecting Ethernet 1 to a switch, the IconMaster
Control Panel must be connected to the same switch.
5. Connect the two Ethernet ports as follows:
Ethernet 1 (connection for MKE-3901 control) to a switch using a straight-through Ethernet cable
Ethernet 2 (two connection options for MGI-3903 control and logo download)
• To the same switch as Ethernet 1 using a normal Ethernet cable
• To a dedicated switch used for the MGI functionality using a normal
Ethernet cable
6. Power up the system.
3. Set the IP Address for the MKE-3901 and MGI-3903 Modules
See
“Configuring IP Addresses” on page 119
for more information.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
85
Chapter 4: Router Connections
4. Set the NSM Card-Edge Parameters
Note
See the Installation and Operation Manual for your NEO module for more information about setting parameters.
1. Press the left (Esc) button until the NSM message appears on the VFD display
2. Press the right (Sel) button.
3. Use the toggle switch (Nav) to scroll through the parameter list until Setup is highlighted.
4. Press the right (Sel) button.
5. Use the toggle switch (Nav) to scroll through the parameter list until Nav
Mode is highlighted.
6. Press the right (Sel) button.
7. Use the toggle switch (Nav) to scroll through the parameter list until All
List is highlighted.
8. Press the right (Sel) button.
9. Press the left (Esc) button.
10. Press the left (Esc) button again.
11. Use the toggle switch (Nav) to scroll through the parameter list until XY
Level is highlighted.
12. Press the right (Sel) button.
13. Use the toggle switch (Nav) to scroll through the values until 2 (on the first
NSM) or 3 (on the second NSM) is reached.
14. Press the left (Esc) button to set the value.
15. Use the toggle switch (Nav) to scroll through the parameter list until
SrcOffset is highlighted.
16. Press the right (Sel) button.
17. Use the toggle switch (Nav) to scroll through the values until 1 is reached.
18. Press the left (Esc) button to set the value.
19. Use the toggle switch (Nav) to scroll through the parameter list until
DestOffset is highlighted.
20. Press the right (Sel) button.
21. Use the toggle switch (Nav) to scroll through the values until 0 is reached.
22. Press the left (Esc) button to set the value.
86 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 4: Router Connections
Sample Configuration 3: IconMaster System with Internal (Two
Channel) Audio and Video NSM Routers and Optional
ICONM-BO-VAC Module
This section describes the connections that are required in a typical configurations involving an IconMaster system, with two channel audio and video NSM router modules and an optional breakout module. You can place the
NSM modules anywhere in the same NEO frame as the IconMaster system.
Figure 4-8 on page 88 shows a detailed illustration of this process.
1. Configure the NSM Modules
Note
The first NSM module will provide Inputs 1 to 5; the second
NSM module will provide Inputs 6 to 12.
1. Set the NEO NSM back module to Unterminated reference: a.
Remove the NSM back module from the NEO Frame.
b. Locate jumper J11 on the NEO NSM back module (see
c.
Set the NEO NSM back module to Unterminated reference by setting
J11 as shown. d. Reinstall the NSM back module into the NEO frame.
Jumper JP1 set to
Unterminated
Figure 4-7. Jumper J11 on the NSM Back Module
2. On the first NSM back module, connect a maximum of 5 audio inputs to the
BNC connections labeled In 1 to In 5.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
87
Chapter 4: Router Connections
Figure 4-8. IconMaster System with Internal (Two Channel) Audio and Video NSM Routers and
Optional ICONM-BO-VAC Module
88 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 4: Router Connections
3. On the second NSM back module, connect a maximum of 7 video audio inputs to the BNC connections labeled In 1 to In 7.
4. Connect Out 1 on the first NSM to AES Bus A on the MKA-3901. This can be done by direct connection, or by ICONM-BO-VAB or
ICONM-BO-VAC breakout module connection.
5. Connect Out 2 on the first NSM to AES Bus B on the MKA-3901.
6. Connect Out 1 on the second NSM to In 6 on the first NSM.
7. Connect Out 2 on the second NSM to In 7 on the first NSM.
Audio output 1 from the third NSM router must be connected to Bus A In 2 on the breakout module as shown in
Bus A In 2
Figure 4-9. Audio Output 1 From Third NSM Router to Bus A In 2
Audio output 2 from the third NSM router must be connected to Bus B In 2 on
the breakout module, as indicated in Figure 4-10
.
Bus B In 2
Figure 4-10. Audio Output 2 From Third NSM Router to Bus B In 2
When using the IOCON-BO-VAB breakout module, audio output 1 from the third NSM router must be connected to Input Bus A2 on the breakout module, as indicated in Table 2-9 on page 54 .
Audio output 2 from the third NSM must be connected to Input Bus B2 on the breakout module, as indicated in Table 2-9 on page 54 .
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
89
Chapter 4: Router Connections
System Configurations—Panacea Routers
Note
System configurations for NEO routers start on page 78
. System configurations for Platinum routers start on
.
This section describes the connections that are required in some typical configurations involving Panacea external routers. The following Panacea router configurations are described in this section:
• IconMaster system with external Panacea video router and optional
ICONM-BO-V module
• IconMaster System with external Panacea video router and optional
ICONM-BO-V module with optional SPT-LSERIAL serial protocol translator
• IconMaster system with external Panacea clean quiet video router and optional ICONM-BO-V module with optional SPT-LSERIAL serial protocol translator
• IconMaster system with external Panacea (single channel) audio and video routers and optional ICONM-BO-VAC module with optional
SPT-LSERIAL serial protocol translator
• IconMaster system with external Panacea (two channel) audio and video routers and optional ICONM-BO-VAC module with optional
SPT-LSERIAL serial protocol translator
90 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 4: Router Connections
Sample Configuration 1: IconMaster System, External Panacea
Video Router, Optional ICONM-BO-V Module
This section describes the connections that are required in a typical configurations involving an IconMaster system with a Panacea video router and
an optional breakout module. Figure 4-12 on page 92
shows a detailed illustration of this process.
1. Configuring the Panacea Router
Before you can make any connections to an IconMaster, the Panacea router must already be configured as desired. If your Panacea router is already operational, you do not need to configure it. If, however, your Panacea router is not already operational, you must install and configure it as desired for your facility. See the Panacea Series Frame and Modules Installation,
Configuration, and Operation Manual for detailed information.
2. Make Connections on the Panacea and ICONM-BO-V Breakout Module
When using the ICONM-BO-V breakout module, the serial port of the Panacea router must be connected to the RS-232/422-A, -B, or -E port on the breakout module as indicated in
RS-232/422-E Port
Figure 4-11. RS-232/422-E Port on the ICONM-BO-V Breakout Module
3. Make Connections on the Panacea and MKE-3901
1. On the Panacea back module, connect a maximum of 16 video inputs to the
BNC connections labeled Input 1 to Input 16.
2. Connect Output 1 on the Panacea to Input Bus A on the MKE-3901.
3. Connect Output 2 on the Panacea to Input Bus B on the MKE-3901.
4. Connect your station reference to the Sync connection of the Panacea back module.
5. Terminate one of the XY BNC connectors on the Panacea router.
6. Connect the serial port of the Panacea router to Serial Port E in the Multi
Function I/O connector on the MKE-3901.
This can be done in either of these two ways.
• Direct connection
• ICONM-BO-V breakout module connection
7. On the MKE-3901 back module, connect the Key 1 input source to Key 1 and Fill 1 as appropriate.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
91
Chapter 4: Router Connections
Figure 4-12. IconMaster System with External Panacea Video Router and Optional ICONM-BO-V
Module
92 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 4: Router Connections
8. On the MKE-3901 back module, connect the Key 2 input source to Key 2 and Fill 2 as appropriate.
9. On the MKE-3901 back module, supply Squeeze Bkgd by an external router.
Note
If you are connecting Ethernet 1 to a switch, the IconMaster control panel must be connected to the same network.
10. Connect the two Ethernet ports as follows:
Ethernet 1 (connection for MKE-3901 control) to a switch using a straight-through Ethernet cable
Ethernet 2 (two connection options for MGI-3903 control and logo download)
• To the same switch as Ethernet 1 using a normal Ethernet cable
• To a dedicated switch used for the MGI functionality using a normal
Ethernet cable
11. Power up the system.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
93
Chapter 4: Router Connections
Sample Configuration 2: IconMaster System, External Panacea
Video Router, Optional ICONM-BO-V Module, Optional
SPT-LSERIAL
This section describes the connections that are required in a typical configurations involving an IconMaster system with a Panacea video router, an optional breakout module, and an optional SPT-LSERIAL serial protocol translator.
shows a detailed illustration of this process.
1. Configure the Panacea Router
Before you can make any connections to an IconMaster, the Panacea router must already be configured as desired. If your Panacea router is already operational, you do not need to configure it. If, however, your Panacea router is not already operational, you must install and configure it as desired for your facility. See the Panacea Series Frame and Modules Installation,
Configuration, and Operation Manual for detailed information.
2. Make Connections on the Panacea and ICONM-BO-V Breakout Module
When using the ICONM-BO-V breakout module, the serial port of the Panacea router must be connected to the RS-232/422-A, -B, or -E port on the breakout module as indicated in
.
RS-232/422-E Port
Figure 4-13. RS-232/422-E Port on the ICONM-BO-V Breakout Module
3. Make Connections on the Panacea and MKE-3901
1. On the Panacea back module, connect a maximum of 16 video inputs to the
BNC connections labeled Input 1 to Input 16.
2. Connect Output 1 on the Panacea to Input Bus A on the MKE-3901.
3. Connect Output 2 on the Panacea to Input Bus B on the MKE-3901.
4. Connect your station reference to the Sync connection of the Panacea back module.
5. Terminate one of the XY BNC connectors on the Panacea router.
6. Connect the serial port of the Panacea router to Serial Port E in the Multi
Function I/O connector on the MKE-3901.
This can be done in either of these two ways.
• Direct connection
• ICONM-BO-V breakout module connection
94 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 4: Router Connections
Figure 4-14. IconMaster System with External Panacea Video Router and Optional ICONM-BO-V
Module with Optional SPT-LSERIAL
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
95
Chapter 4: Router Connections
7. On the MKE-3901 back module, connect the Key 1 input source to Key 1 and Fill 1 as appropriate.
8. On the MKE-3901 back module, connect the Key 2 input source to Key 2 and Fill 2 as appropriate.
9. On the MKE-3901 back module, supply Squeeze Bkgd by an external router.
Note
If you are connecting Ethernet 1 to a switch, the IconMaster control panel must be connected to the same switch.
10. Connect the two Ethernet ports as follows:
Ethernet 1 (connection for MKE-3901 control) to a switch using a straight-through Ethernet cable
Ethernet 2 (two connection options for MGI-3903 control and logo download)
• To the same switch as Ethernet 1 using a normal Ethernet cable
• To a dedicated switch used for the MGI functionality using a normal
Ethernet cable
11. Power up the system.
4. Make Connections on the Panacea and SPT
The IconMaster is installed in the control line, as shown in the example in
• The maximum allowable distance for each segment of the X-Y coaxial cable run is 2,000 ft (609 m).
• The maximum length for each RS-232 segment is 50 ft (15 m).
• The maximum length for each RS-422 segment is 2,000 ft (609 m).
• Up to 64 additional serial ports may be added.
Figure 4-15 on page 97 shows the connector pin assignments on both ends of
the connection (the cable wiring description is shown between the connectors).
96 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 4: Router Connections
Figure 4-15. Cable Wiring Details for IconMaster
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
97
Chapter 4: Router Connections
Table 4-1. Power Requirements for SPT-LSERIAL
PD9200PL6A Adaptor Description
Locations with 110-127 volt electrical systems should use the PD9200PL6A adaptor*
Input voltage: 120 VAC, 60 Hz
Input current: 60 mA max.
Output voltage: 9.0 VDC
Output current: 200 mA
Output connector: 5.5 mm x 2.5 mm female barrel power plug with positive center
PD9300EPL6A Adaptor Description
Locations with 220-240 volt electrical systems should use the PD9300EPL6A adaptor
*
Input voltage: 230 VAC, 5 0Hz
Input current: 40 mA max
Output voltage: 9.0 VDC
Output current: 30 0mA
Output connector: 5.5 mm x 2.5 mm female barrel power plug with positive center
* If you did not receive the correct adaptor for your electrical system, please contact your Customer Service representative.
98 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 4: Router Connections
Sample Configuration 3: IconMaster System, External Panacea
Clean/Quiet Switch Video Router, Optional ICONM-BO-V Module,
Optional SPT-LSERIAL
This section describes the connections that are required in a typical configuration involving an IconMaster system with a Panacea clean/quiet switch router, an optional breakout module, and an optional SPT-LSERIAL
serial protocol translator. Figure 4-17 on page 100
shows a detailed illustration of this process.
1. Configure the Panacea Router
Before you can make any connections to an IconMaster, the Panacea router must already be configured as desired. If your Panacea router is already operational, you do not need to configure it. If, however, your Panacea router is not already operational, you must install and configure it as desired for your facility. See the Panacea Series Frame and Modules Installation,
Configuration, and Operation Manual for detailed information.
2. Make Connections on the Panacea and ICONM-BO-V Breakout Module
When using the ICONM-BO-V breakout module, the serial port of the Panacea router must be connected to the RS-232/422-A, -B, or -E port on the breakout module as indicated in
.
RS-232/422-E Port
Figure 4-16. RS-232/422-E Port on the ICONM-BO-V Breakout Module
3. Make Connections on the Panacea and MKE-3901
1. On the Panacea back module, connect a maximum of 16 video inputs to the
BNC connections labeled Input 1 to Input 16.
2. Connect Output 1 on the Panacea to Input Bus A on the MKE-3901.
3. Connect Output 2 on the Panacea to Input Bus B on the MKE-3901.
4. Connect your station reference to the Sync connection of the Panacea back module.
5. Terminate one of the XY BNC connectors on the Panacea router.
6. Connect the serial port of the Panacea router to Serial Port E in the Multi
Function I/O connector on the MKE-3901.
This can be done in either of these two ways.
• Direct connection
• ICONM-BO-V breakout module connection
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
99
Chapter 4: Router Connections
Figure 4-17. IconMaster System with External Panacea Clean/Quiet Switch Video Router, Optional
ICONM-BO-V Module and Optional SPT-LSERIAL
100 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 4: Router Connections
7. On the MKE-3901 back module, connect the Key 1 input source to Key 1 and Fill 1 as appropriate.
8. On the MKE-3901 back module, connect the Key 2 input source to Key 2 and Fill 2 as appropriate.
9. On the MKE-3901 back module, supply Squeeze Bkgd by an external router.
Note
If you are connecting Ethernet 1 to a switch, the IconMaster control panel must be connected to the same switch.
10. Connect the two Ethernet ports as follows:
Ethernet 1 (connection for MKE-3901 control) to a switch using a straight-through Ethernet cable
Ethernet 2 (two connection options for MGI-3903 control and logo download)
• To the same switch as Ethernet 1 using a normal Ethernet cable
• To a dedicated switch used for the MGI functionality using a normal
Ethernet cable
11. Power up the system.
4. Make Connections on the Panacea and SPT
The IconMaster is installed in the control line, as shown in the example in
.
• The maximum allowable distance for each segment of the X-Y coaxial cable run is 2,000 ft (609 m).
• The maximum length for each RS-232 segment is 50 ft (15 m).
• The maximum length for each RS-422 segment is 2,000 ft (609 m).
• Up to 64 additional serial ports may be added.
Figure 4-15 on page 97 shows the connector pin assignments on both ends of
the connection (the cable wiring description is shown between the connectors).
Table 4-1 on page 98 shows the power requirements for the SPT-LSERIAL
adaptors.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
101
Chapter 4: Router Connections
Sample Configuration 4: IconMaster System, External Panacea
(Single Channel) Audio and Video Routers, Optional
ICONM-BO-VAC Module, Optional SPT-LSERIAL
This section describes the connections that are required in a typical configuration involving an IconMaster system with a single channel Panacea audio and video routers, an optional breakout module, and an optional
SPT-LSERIAL serial protocol translator.
Figure 4-20 on page 103 shows a
detailed illustration of this process.
1. Configure the Panacea Router
Before you can make any connections to an IconMaster, the Panacea router must already be configured as desired. If your Panacea router is already operational, you do not need to configure it. If, however, your Panacea router is not already operational, you must install and configure it as desired for your facility. See the Panacea Series Frame and Modules Installation,
Configuration, and Operation Manual for detailed information.
2. Make Connections on the Panacea and ICONM-BO-VAC Breakout Module
When using the ICONM-BO-VAC breakout module and multiple Panacea routers (multi-level), the audio output 1 from the level 1 Panacea router must be
connected to Bus A In 1 on the breakout module as indicated in Figure 4-18 .
Bus A In 1
Figure 4-18. Audio 1, Level 1 Panacea Connection to ICONM-BO-VAC
Likewise, the audio output 2 from the level 1 Panacea router must be connected
to Bus B In 1 on the breakout module as indicated in Figure 4-19 .
Bus B In 1
Figure 4-19. Audio 2, Level 1 Panacea Connection to ICONM-BO-VAC
102 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 4: Router Connections
Figure 4-20. IconMaster System with External Panacea (Single Channel) Audio and Video Routers,
Optional ICONM-BO-VAC Module, Optional SPT-LSERIAL
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
103
Chapter 4: Router Connections
Audio output 1 from the level 2 Panacea router must be connected to Bus A In
2 on the breakout module, as indicated in Figure 4-21
.
Bus A In 2
Figure 4-21. Audio 1, Level 2 Panacea Connection to ICONM-BO-VAC
Audio output 1 from the level 2 Panacea router must be connected to Bus B In 2 on the breakout module, as indicated in
.
Bus B In 2
Figure 4-22. Audio 2, Level 2 Panacea Connection to ICONM-BO-VAC
When using the ICON-BO-VAB breakout module and a Panacea router (single level), audio output 1 from the Panacea router must be connected to Input Bus
A1 on the breakout module as indicated in
Likewise, audio output 2 from the Panacea router must be connected to Input
Bus B1 on the breakout module as indicated in
.
Audio output 1 from the level 2 Panacea router must be connected to Input Bus
A2 on the breakout module as indicated in
Audio output 2 from the level 2 Panacea router must be connected to Input Bus
B2 on the breakout module as indicated in
3. Make Connections on the Panacea and MKE-3901
1. On the Panacea back module, connect a maximum of 16 video inputs to the
BNC connections labeled Input 1 to Input 16.
2. Connect Output 1 on the Panacea to Input Bus A on the MKE-3901.
3. Connect Output 2 on the Panacea to Input Bus B on the MKE-3901.
4. Connect your station reference to the Sync connection of the Panacea back module.
5. Terminate one of the XY BNC connectors on the Panacea router.
6. Connect the serial port of the Panacea router to Serial Port E in the Multi
Function I/O connector on the MKE-3901. This can be done by direct connection or via the ICONM-BO-V breakout module connection.
104 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 4: Router Connections
7. On the MKE-3901 back module, connect the Key 1 input source to Key 1 and Fill 1 as appropriate.
8. On the MKE-3901 back module, connect the Key 2 input source to Key 2 and Fill 2 as appropriate.
9. On the MKE-3901 back module, supply Squeeze Bkgd by an external router.
Note
If you are connecting Ethernet 1 to a switch, the IconMaster control panel must be connected to the same switch.
10. Connect the two Ethernet ports as follows:
Ethernet 1 (connection for MKE-3901 control) to a switch using a straight-through Ethernet cable
Ethernet 2 (two connection options for MGI-3903 control and logo download)
• To the same switch as Ethernet 1 using a normal Ethernet cable
• To a dedicated switch used for the MGI functionality using a normal
Ethernet cable
11. Power up the system.
4. Make Connections on the Panacea and SPT
The IconMaster is installed in the control line, as shown in the example in
.
• The maximum allowable distance for each segment of the X-Y coaxial cable run is 2,000 ft (609 m).
• The maximum length for each RS-232 segment is 50 ft (15 m).
• The maximum length for each RS-422 segment is 2,000 ft (609 m).
• Up to 64 additional serial ports may be added.
Figure 4-15 on page 97 shows the connector pin assignments on both ends of
the connection (the cable wiring description is shown between the connectors).
Table 4-1 on page 98 shows the power requirements for the SPT-LSERIAL
adaptors.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
105
Chapter 4: Router Connections
Sample Configuration 5: IconMaster System with External
Panacea (Two Channel) Audio and Video Routers, Optional
ICONM-BO-VAC Module, Optional SPT-LSERIAL
This section describes the connections that are required in a typical configuration involving an IconMaster system with two channel Panacea audio and video routers, an optional breakout module, and an optional SPT-LSERIAL
serial protocol translator. Figure 4-25 on page 107
shows a detailed illustration of this process.
1. Configure the Panacea Router
Before you can make any connections to an IconMaster, the Panacea router must already be configured as desired. If your Panacea router is already operational, you do not need to configure it. If, however, your Panacea router is not already operational, you must install and configure it as desired for your facility. See the Panacea Series Frame and Modules Installation,
Configuration, and Operation Manual for detailed information.
2. Make Connections on the Panacea and ICONM-BO-VAC Breakout Module
When using the ICONM-BO-VAC breakout module and multiple Panacea routers (multi-level), the audio output 1 from the level 1 Panacea router must be
connected to Bus A In 1 on the breakout module as indicated in Figure 4-23 .
Bus A In 1
Figure 4-23. Audio 1, Level 1 Panacea Connection to ICONM-BO-VAC
Likewise, the audio output 2 from the level 1 Panacea router must be connected
to Bus B In 1 on the breakout module as indicated in Figure 4-24 .
Bus B In 1
Figure 4-24. Audio 2, Level 1 Panacea Connection to ICONM-BO-VAC
106 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 4: Router Connections
Figure 4-25. IconMaster System with External Panacea (Two Channel) Audio and Video Routers,
Optional ICONM-BO-VAC Module, Optional SPT-LSERIAL
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
107
Chapter 4: Router Connections
Audio output 1 from the level 2 Panacea router must be connected to Bus A In
2 on the breakout module, as indicated in Figure 4-26
.
Bus A In 2
Figure 4-26. Audio 1, Level 2 Panacea Connection to ICONM-BO-VAC
Audio output 1 from the level 2 Panacea router must be connected to Bus B In 2 on the breakout module, as indicated in
.
Bus B In 2
Figure 4-27. Audio 2, Level 2 Panacea Connection to ICONM-BO-VAC
Audio outputs 3 and 4 from the Panacea level 3 and 4 routers connect to Bus A and B In 3 and 4, respectively.
When using the ICON-BO-VAB breakout module and a Panacea router (single level), audio output 1 from the Panacea router must be connected to Input Bus
A1 on the breakout module as indicated in
Likewise, audio output 2 from the Panacea router must be connected to Input
Bus B1 on the breakout module as indicated in
.
Audio output 1 from the level 2 Panacea router must be connected to Input Bus
A2 on the breakout module as indicated in
Audio output 2 from the level 2 Panacea router must be connected to Input Bus
B2 on the breakout module as indicated in
Audio outputs 3 and 4 from the Panacea level 3 and 4 routers connect to Input
Bus A and B, 3 and 4, respectively.
3. Make Connections on the Panacea and MKE-3901
1. On the Panacea back module, connect a maximum of 16 video inputs to the
BNC connections labeled Input 1 to Input 16.
2. Connect Output 1 on the Panacea to Input Bus A on the MKE-3901.
3. Connect Output 2 on the Panacea to Input Bus B on the MKE-3901.
4. Connect your station reference to the Sync connection of the Panacea back module.
5. Terminate one of the XY BNC connectors on the Panacea router.
108 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 4: Router Connections
6. Connect the serial port of the Panacea router to Serial Port E in the Multi
Function I/O connector on the MKE-3901.
This can be done by direct connection or via the ICONM-BO-V breakout module connection.
7. On the MKE-3901 back module, connect the Key 1 input source to Key 1 and Fill 1 as appropriate.
8. On the MKE-3901 back module, connect the Key 2 input source to Key 2 and Fill 2 as appropriate.
9. On the MKE-3901 back module, supply Squeeze Bkgd by an external router.
Note
If you are connecting Ethernet 1 to a switch, the IconMaster control panel must be connected to the same switch.
10. Connect the two Ethernet ports as follows:
Ethernet 1 (connection for MKE-3901 control) to a switch using a straight-through Ethernet cable
Ethernet 2 (two connection options for MGI-3903 control and logo download)
• To the same switch as Ethernet 1 using a normal Ethernet cable
• To a dedicated switch used for the MGI functionality using a normal
Ethernet cable
11. Power up the system.
4. Make Connections on the Panacea and SPT
The IconMaster is installed in the control line, as shown in the example in
.
• The maximum allowable distance for each segment of the X-Y coaxial cable run is 2,000 ft (609 m).
• The maximum length for each RS-232 segment is 50 ft (15 m).
• The maximum length for each RS-422 segment is 2,000 ft (609 m).
• Up to 64 additional serial ports may be added.
Figure 4-15 on page 97 shows the connector pin assignments on both ends of
the connection (the cable wiring description is shown between the connectors).
Table 4-1 on page 98 shows the power requirements for the SPT-LSERIAL
adaptors.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
109
Chapter 4: Router Connections
System Configurations—Platinum Routers
Note
System configurations for NEO routers start on page 78
. System configurations for Panacea routers start on
.
This section describes the connections that are required in some typical configurations involving Platinum external routers. The following Platinum router configurations are described in this section:
• IconMaster System, External Platinum Video Router, Optional
ICONM-BO-V Module
• Sample Configuration 2: IconMaster System, External Platinum Video
Router, Optional CENTRIO multiviewer, Optional JLCooper eBox,
Optional ICONM-BO-V Module
110 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 4: Router Connections
Sample Configuration 1: IconMaster System, External Platinum
Router, Optional ICONM-BO-V Module
This section describes the connections that are required in a typical
configurations involving Platinum external routers. Figure 4-28 on page 112
shows a detailed illustration of this process.
1. Configure Platinum Router
Before you can make any connections to an IconMaster, the Platinum router must already be configured as desired. If your Platinum router is already operational, you do not need to configure it. If, however, your Platinum router is not already operational, you must install and configure it as desired for your facility. See the Platinum Series Frames and Modules Installation,
Configuration, and Operation Manual for detailed information.
On your Platinum router configuration, make sure that you set the video and audio to different levels. For example, if you set the video level to “0,” set the audio level to “1” or higher.
2. Make Connections between the Platinum and MKE-3901
1. On the Platinum router, connect the inputs to the input BNC connections on the appropriate Platinum modules.
2. Terminate the loop-thru (XY) BNC connectors on the communications back panel (PT-CBP).
3. Connect the first desired output on the PT-CBP to Input Bus A on the
MKE-3901.
4. Connect second desired output on the PT-CBP to Input Bus B on the
MKE-3901.
5. On the PT-CBP, connect the station reference to one connector on an available Sync connection.
6. On the MKE-3901 back module, connect the signal Squeeze Bkgd input to an output on the PT-CBP.
Note
The Platinum router serial port baud rate must be set to 38400.
IconMaster can control the Platinum over Ethernet.
7. Connect an available serial port (SERIAL1 or SERIAL2) on the PT-CBP to
Serial Port E in the Multi Function I/O connector on the MKE-3901. This can be done by direct connection or by ICONM-BO-V breakout module connection. When using the ICONM-BO-V breakout module, either serial port of the PT-CBP must be connected to the RS-232/422-A, -B, or -E port on the breakout module as indicated in
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
111
Chapter 4: Router Connections
Figure 4-28. IconMaster System with External Platinum Router Using Serial Control and Optional
ICONM-BO-V Module
112 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 4: Router Connections
RS-232/422-E Port
Figure 4-29. RS-232/422-E Port on the ICONM-BO-V Breakout Module
8. On the MKE-3901 back module, connect the Key 1 input source to Key 1 and Fill 1 as appropriate.
9. On the MKE-3901 back module, connect the Key 2 input source to Key 2 and Fill 2 as appropriate.
Note
If you are connecting Ethernet 1 to a network hub/switch, the
IconMaster control panel must be connected to the same switch.
10. On the MKE-3901 back module, connect the Ethernet 1 connection for
MKE-3901 control to a network hub/switch using a straight-through
Ethernet cable.
11. On the MGI-3903 back module, two Ethernet connection options for
MGI-3903 control and logo download as follows:
• To the same network/hub as Ethernet 1 using a normal Ethernet cable.
• To a dedicated switch used for the MGI functionality using a normal
Ethernet cable.
12. Power up the system.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
113
Chapter 4: Router Connections
Sample Configuration 2: IconMaster System, External Platinum
Router, Optional CENTRIO, Optional JLCooper eBox, Optional
ICONM-BO-V Module
This section describes the connections that are required in a typical
configurations involving Platinum external routers. Figure 4-30 on page 115
shows a detailed illustration of this process.
1. Configure CENTRIO Module
Before you can make any connections to an IconMaster, the CENTRIO multiviewer output module must already be installed in the Platinum frame and configured as desired. If your CENTRIO multiviewer is already operational, you do not need to configure it. If, however, your CENTRIO multiviewer is not already operational, you must install and configure it as desired for your facility.
See the CENTRIO Multiviewer Installation, Configuration, and Operation
Manual and the CENTRIO Layout Designer User Guide for detailed information.
2. Set up eBOX to work with CENTRIO
You will need to configure some settings in CENTRIO’s Layout Designer before you can use the eBOX with CENTRIO.
1. Right click on the CENTRIO device in the Multiviewers window.
2. Select Advanced Configuration.
3. Select the External Devices tab.
4. Select the desired CENTRIO’s “-1” configuration.
5. Under Type, select TSL Protocol.
6. Under Port, select TCP/IP.
7. Under IP, enter the IP address and port.
• The default IP is 192.168.254.102.
• The default port is 23.
8. Click Add.
9. Click Done.
3. Configure Platinum Router
Before you can make any connections to an IconMaster, the Platinum router must already be configured as desired. If your Platinum router is already operational, you do not need to configure it. If, however, your Platinum router is not already operational, you must install and configure it as desired for your facility. See the Platinum Series Frames and Modules Installation,
Configuration, and Operation Manual for detailed information.
On your Platinum router configuration, make sure that you set the video and audio to different levels. For example, if you set the video level to “0,” set the audio level to “1” or higher.
114 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 4: Router Connections
Figure 4-30. IconMaster System with External Platinum Router Using Ethernet Control, CENTRIO, eBox, and Optional ICONM-BO-V Module
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
115
Chapter 4: Router Connections
4. Make Connections between CENTRIO Multiviewer and JLCooper eBOX
Before you can make any connections to an IconMaster, the JLCooper eBOX must already be configured as desired. If your eBOX is already operational, you do not need to configure it. If, however, your eBOX is not already operational, you must install and configure it as desired for your facility. For information about configuring your e-BOX, see your JLCooper eBOX documentation.
5. Make Connections between the Platinum and MKE-3901
1. On the Platinum router, connect the inputs to the input BNC connections on the CENTRIO modules.
2. Terminate the loop-thru (XY) BNC connectors on the communications back panel (PT-CBP).
3. Connect the first desired output on the PT-CBP to Input Bus A on the
MKE-3901.
4. Connect second desired output on the PT-CBP to Input Bus B on the
MKE-3901.
5. On the PT-CBP, connect the station reference to one connector on an available Sync connection.
6. On the MKE-3901 back module, connect the signal Squeeze Bkgd input to the output on the PT-CBP.
Note
The Platinum router serial port baud rate must be set to 38400.
7. Connect an available serial port (SERIAL1 or SERIAL2) on the PT-CBP to
Serial Port E in the Multi Function I/O connector on the MKE-3901. This can be done by direct connection or by ICONM-BO-V breakout module connection. When using the ICONM-BO-V breakout module, either serial port of the PT-CBP must be connected to the RS-232/422-A, -B, or -E port on the breakout module as indicated in
RS-232/422-E Port
Figure 4-31. RS-232/422-E Port on the ICONM-BO-V Breakout Module
8. On the MKE-3901 back module, connect the Key 1 input source to Key 1 and Fill 1 as appropriate.
9. On the MKE-3901 back module, connect the Key 2 input source to Key 2 and Fill 2 as appropriate.
116 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 4: Router Connections
Note
If you are connecting Ethernet 1 to a network hub/switch, the
IconMaster control panel must be connected to the same network.
10. On the MKE-3901 back module, connect the Ethernet 1 connection for
MKE-3901 control to a network hub/switch using a straight-through
Ethernet cable.
11. On the MGI-3903 back module, two Ethernet connection options for
MGI-3903 control and logo download as follows:
• To the same network/hub as Ethernet 1 using a normal Ethernet cable.
• To a dedicated switch used for the MGI functionality using a normal
Ethernet cable.
12. Power up the system.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
117
Chapter 4: Router Connections
118 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 5
Configuring IP Addresses
Setting the IP Address for the MKE-3901 Module
1. Press the left (Esc) button until the message MKE3901 appears on the VFD display.
2. Press the right (Enter) button.
3. Use the toggle switch (Nav) to scroll through the parameter list until Status is highlighted.
4. Press the right (Enter) button.
5. Use the toggle switch (Nav) to scroll through the parameter list until Other is highlighted.
6. Press the right (Enter) button.
7. Use the toggle switch (Nav) to scroll through the parameter list until
IP_Address is highlighted.
8. Press the right (Enter) button.
9. Continue pressing the right (Enter) button until the cursor is under the digit you want to change.
10. Use the toggle switch (Nav) to change the digit.
11. Press the right (Enter) button to move to the next digit.
12. Repeat the previous three steps until you have changed the IP address.
13. Press the right (Enter) button until the cursor is under the space at the end of the IP address.
14. Press the left (Esc) button to accept the change.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
119
Chapter 5: Configuring IP Addresses
Setting the IP Address for the MGI-3903 Module
1. Press the left (Esc) button until the message MGI-3903-R appears on the
VFD display.
2. Press the right (Enter) button.
3. Use the toggle switch (NAV) to scroll through the parameter list until
IP_Address is highlighted.
4. Press the right (Enter) button.
5. Continue pressing the right (Enter) button until the cursor is under the digit you want to change.
6. Use the toggle switch (Nav) to change the digit.
7. Press the right (Enter) button to move to the next digit.
8. Repeat the previous three steps until you have changed the IP address.
9. Press the right (Enter) button until the cursor is under the space at the end of the IP address.
10. Press the left (Esc) button to accept the change.
Changing the Control Panel IP Address
1. Access the Service Menu by simultaneously pressing all four LCD buttons in the center Parameter Control Cluster .
2. Turn the left scroll knob until the PNL IP ADDR parameter appears.
Reading from left to right, you will see a display of the control panel’s current IP address.
3. Select the button that contains the IP address component that you want to change, and then turn the right scroll knob to change the number on that button.
4. After you enter the last digit of the IP Address, press the right knob to save the new IP Address.
5. When finished, turn the left scroll knob until the PUSH EXIT parameter appears.
120 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 5: Configuring IP Addresses
Set the IP Address for the 3901RES-E Module
To use CCS-P control and monitoring of your IconMaster master control switcher, Navigator and NUCLEUS operate through the frame’s optional
3901RES-E module.
To change the resource module network settings, at least one of the processing modules in the frame must support the Frame IP feature.
Note
The IRB-3901, GPI-3901, and MGI-3901 NEO modules do not support Frame IP. Some older NEO modules that have not been upgraded also do not support this feature.
To configure the IP address for this module, follow these steps:
1. Using the card-edge of a NEO processing module in the same frame as the resource module, scroll down and then select the Setup menu at the end of the parameter list.
2. Select Frame IP, and then press the Enter button.
3. Select IP Address, and then press the Enter button.
The card-edge screen shows the current IP Address of the active resource module.
If the message Not Supported appears, correct the problem by ensuring that the active resource module’s SW2 DIP 8 is in the down position.
4. Using the Enter button, scroll to the digit in the IP Address.
5. Press the toggle switch up or down to change the IP number, and then scroll past the end of the number to accept the change.
The following tips will help you enter an IP address:
• To backspace from the selected number in the IP to the one before it, scroll using the Nav+/Nav- until you reach the back arrow ( ), and then press the Enter button.
• Delete the selected number in the IP by scrolling using the
Nav+/Nav- switch until the delete character (
X
) is displayed, and then press the Enter button.
• (The delete character is located after the number “0”)
• Use Nav+ (up) to scroll up through numbers, increasing the selected number.
• Use Nav- (down) to scroll down through numbers, decreasing the selected number.
6. Press the Escape/Exit button, and then repeat the number changing process for the Subnet and Gateway if necessary.
7. Press the Escape/Exit button twice to send the new IP Address to the resource module.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
121
Chapter 5: Configuring IP Addresses
8. Reboot the resource module by pulling it out of its slot and reinserting it.
9. Confirm the resource module’s corrected IP Address by again using the card edge to verify the IP Address, Subnet, and Gateway IP settings. Then ping the resource module via the PC, as described in the following steps: a.
Click Start, point to Programs > Accessories and then click
Command Prompt to open the Command Prompt window on the PC.
b. After the command prompt, type the following message, and then press
ENTER: ping 192.168.248.50
(or the actual IP Address of your resource module)
The message should reply back. If the ping does not work, see
“Troubleshooting” on page 104 .
Initializing IconMaster
Once you have completed the system wiring, the following settings are required:
• Network settings
• Operating standard
• System timing
Network Settings
The default IP address will function correctly in a “one frame and one panel” configuration if both frame and panel are connected to the same switch that is not connected to a network server or router.
If you have changed the IP address on the card edge of the MKE-3901 module, you must make the same change in the Network dialog box in the ICU software
(see
To change the network settings of the IconMaster control panel, refer to the
Panel Network Configuration dialog box in ICU software (see page 203
).
Alternatively, you can use the Service Menu change the IP address of the
IconMaster control panel on the panel itself. Refer to the IconMaster Functional
Operation and Configuration Manual for more information.
Operating Standard
To change the operating standard, use the Genlock and Standards dialog box in
the ICU software (see page 184
).
System Timing
To make changes to the IconMaster timing, use the Genlock and Standards
dialog box in the ICU software (see page 184
).
122 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 6
Connecting an IconMaster to an EAS Device
Overview
The federal Emergency Alert System (EAS) enables broadcasters, cable providers, and emergency managers to receive, store, forward, and originate emergency alert messages as required by the Federal Communications
Commission. EAS allows broadcast stations, cable systems, participating satellite companies, and emergency managers, and other services to send and receive emergency information quickly and automatically, even if these facilities are unattended. Specially equipped devices decode EAS messages for distribution.
The IconMaster can be connected directly to an EAS encoder/decoder or character generator, thus enabling you to insert emergency notification messages directly into the broadcast stream as a regular scrolling text crawl.
An external EAS receiver is required to allow this feature to become operational.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
123
Chapter 6: Connecting an IconMaster to an EAS Device
Communication Protocols
The IconLogo currently supports three communication protocols employed by
EAS devices: TFT
1
, Sage
2
, and Gorman-Redlich (GR)
3
.
RS-232 Connection
The EAS device is connected to the RS-232-D port on the IconMaster
ICONM-BO-V breakout module. See Table 2-7 on page 50
for pinout details. If the IconMaster ICONM-BO-V breakout module is not being used, the EAS device must be wired directly to the Multi-Function I/O connector on the
MKE-3901-BM (see
Figure 2-25 on page 38 ). Pins 57 (RS-232-D-RX) and 58
(RS-232-D-TX) are reserved for this purpose. See
. (One ground connection is also required.)
Configuring the EAS Device
EAS devices need to be set to 9600 baud and Standard or Generic CG protocol in order to work correctly with IconMaster.
For basic configurations and preparations please see the specific EAS device user manual. No additional special settings are needed to communicate with an
IconMaster. The standard signal will be taken out from the EAS device’s serial port.
IconMaster can be configured two different ways when using IconMaster's
Audio Over to insert the EAS audio message into the program stream.
An important consideration is that the EAS audio message is not always the same duration as the EAS logo message.
Method 1 (preferred): IconMaster controls EAS logo insertion and EAS audio insertion separately.
1. Configure the EAS receiver to output a GPI output for the duration of the audio message.
124
1. “TFT” is a trademark of TFT Inc., San Jose, California.
2. “Sage” systems are products of Harris Corporation, Melbourne, Florida.
3. Gorman-Redlich Manufacturing Co., Athens, Ohio.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 6: Connecting an IconMaster to an EAS Device
2. Connect this GPI output to an IconMaster GPI input, and configure
IconMaster to use this GPI input as Key to Air (as in
EAS Box can hold the Audio Over active for the duration of the EAS audio message.
Figure 6-1. GPI Settings for EAS Logo Insertion
3. Ensure that the EAS Audio setting in the System Configuration menu is set to NONE.
Figure 6-2. EAS Audio Settings in the System Configuration Menu
With these settings, IconMaster will enable the selected Audio Over whenever the GPI input is triggered, and for as long as the GPI input is triggered. The duration of the Audio Over key is independent of the duration of the EAS
message.
Method 2: IconMaster controls EAS logo and audio together.
IconMaster can be configured to automatically enable an Audio Over when an
EAS message is received.
The following menu can be found in the ICU System Configuration screen, and shows that Audio Over 1 will automatically be keyed into PGM video when an EAS message is received, and only for the duration of the EAS message.
Figure 6-3. EAS Audio Settings in the System Configuration Menu
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
125
Chapter 6: Connecting an IconMaster to an EAS Device
126 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 7
Machine Control
Connecting for Machine Control Use
Note
You cannot use this configuration on a network.
The serial connector RS-232-A on the ICONM-BO-V video breakout module is dedicated for machine control use. To connect the IconMaster system to a VTR, follow these steps.
1. Using a straight-through RS-232 serial cable, connect RS-232-A on the
ICONM-BO-V video breakout module to the serial connector on an
SPT-LSERIAL or an SPT-LXYTOXY serial protocol translator.
Note
If re-assigned to port B or port E, use a null-modem cable instead of this straight-through cable.
2. Using a coaxial cable, connect COAX on the SPT to COAX on the VTR specific SPT. (For example, if you are connecting to a Sony VTR, you would be using an SPT-LXYTOSONY.)
3. Using an RS-422 serial cable, connect the serial connector on the SPT to the
VTR.
4. Follow the VTR manufacturer’s instructions for other connections to the
IconMaster system.
shows a sample connection using a Sony tape machine.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
127
Chapter 7: Machine Control
RS-422
RS-232
SPT-LSERIAL SPT -XYTOSONY
ICONM-BO-V Video Breakout Module
Sony control unit
Figure 7-1. Sample Sony Machine Control Connections
Edge Protocol Gateway
The Edge protocol gateway provides external connectivity to any Leitch/Harris routing system. It translates between Leitch/Harris and other manufacturers’ routing control systems. On an IconMaster system, the Edge would be connected to either a Panacea or a Platinum router to access third-party protocols and commands.
Before you can make any connections to an IconMaster, the Edge must already be configured as desired. If your Edge is already operational, you do not need to configure it. If, however, your Edge is not already operational, you must install and configure it as desired for your facility. See the Edge Protocol Gateway
Installation and Frame Configuration Manual for detailed information.
You can use an Edge to allow the IconMaster to “talk” to certain third party routing systems. See the Protocol Translation Functions Firmware Installation,
Configuration, And Operation Manual for a list of supported third-party protocols and commands.
128 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 8
Automation Setup
Connecting a DAL Harris Automation System to
IconMaster
The following information is specific to a DAL Harris Automation system used with the McCurdy SER-8-IF serial breakout box, and may not apply to any other automation system setups.
1. Using the cable provided, connect the DAL Harris Automation System to port J19 on the McCurdy SER-8-IF serial breakout box.
2. Choose one of the following options:
• If using the IconMaster ICONM-BO-V breakout module, connect port
RS-232/422-B on the ICONM-BO-V module to the port on the
McCurdy SER-8-IF serial breakout box configured for automation. See
Table 2-7 on page 50 for pinouts. See
Table 2-1 on page 34 for setting
the serial port standard.
IconMaster
7
8
Pin Function
2 TX- (data sent by router)
3 RX+ (data received by router)
TX+ (data sent by router)
RX- (data received by router)
* For use with SER16 D-Series adapter
<===> 6
1
<===>
<===> 3
2
<===>
RJ45
Port
Pinouts
*
5
8
McCurdy
Breakout
Pin Function
Rx -
Tx +
4
9
Rx +
Tx -
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
129
Chapter 8: Automation Setup
• If connecting directly to the IconMaster system, connect the multifunction I/O on the MKE-3901-BM to the port on the McCurdy
SER-8-IF serial breakout box configured for automation. See Table 2-7 on page 50
for pinouts. See
for setting the serial port standard.
IconMaster
Pin Function
20 RSxx2-B TX -
14 RSxx2-B RX +
41 RSxx2-B TX +
15 RSxx2-B RX -
*
For use with SER16 D-Series adapter
<===> 6
<===> 1
<===> 3
<===> 2
RJ45
Port
Pinouts
*
McCurdy
Breakout
8
4
Pin Function
5 Rx-
9
Tx+
Rx+
Tx-
D-Series System Capabilities With IconMaster
The ADC-100 playout automation includes support for controlling the
IconMaster master control switcher.
The following IconMaster capabilities are supported:
• Transitions between main sources (V-fade, cut-fade, fade-cut, and mix) at three predefined speeds (slow, medium and fast) in addition to cuts.
• Audio-Overs with either of two external inputs
• Control of the six IconMaster keyers (two using external key/fill source, four using the internal logo store).
• Selection of logos from the IconMaster’s internal logo store (this requires configuring a corresponding source machine entry in the source specification table src.tbl.
• Control of effects (this is not functioning correctly with IconMaster firmware v1.4).
Audio-video breakaways not supported: Although the IconMaster supports audio-video breakaways under certain circumstances, using an audio-video break away interferes with IconMaster functions, so the D-Series interface does not support using this capability.
The IconMaster should be running firmware release 1.4 or later. This interface will not function properly with earlier IconMaster firmware versions.
Configuration
Serial Port Configuration in port.cfg
Serial Port
Configure the serial port used to communicate with the IconMaster with
130 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 8: Automation Setup
USAGE=swrn SPEED=38400 NDATA=8 PARITY=NONE NSTOP=1
DUPLEX=FULL HANDSHAKE=NONE, where n is the index of the swr.tbl entry describing the IconMaster switcher.
Breakout Module Connection
Connect the automation serial port to the connector labeled RS232/422-B on the
IconMaster breakout module.
• This port can be configured for either RS-232 or RS-422 connections.
• Ensure both jumper J18 of the MKE-3901 board and the jumper pack A1 on the breakout module are both set to match the appropriate serial communication standard (normally RS-422 for a D-MAS system using
McCurdy SER-4, SER-8 or SER-12 card via a CON-8 or MUX8/800).
Switcher Configuration in swr.tbl
An IconMaster switcher requires the following settings in the swr.tbl specification table.
Table 8-1. swr.tbl Specification Settings
swr.tbl Field Set to
Switcher type
Description
Parameter
Number of Outputs
Number of program inputs
Number of program levels
Number of over inputs
Number of over levels
Switcher Latency time
ICONMASTER
Text describing switcher
Leave Blank
1
Number of valid inputs (between 1 and 12)
1
1 for a single audio-over input, or 2 if both audio-over inputs are used
9 blank (or a time in format ss:ff)
Level Mappings for IconMaster
The automation main audio and video levels are always mapped to the audio and video levels of the IconMaster. The mapping of D-MAS subevent fields and switching levels to the keyers, audio mixer and DVE engine of the IconMaster is controlled by the Switcher Level n fields in swr.tbl.
If a Switcher Level n field is left blank, the corresponding facility of the
IconMaster is not associated with an automation switching level and is not used.
Table 8-2. swr.tbl Mapping
swr.tbl Field
Switcher Level 1
Switcher Level 2
Maps Requests to
Keyer 1 (external source)
Keyer 2 (external source)
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
131
Chapter 8: Automation Setup
Table 8-2. swr.tbl Mapping
Switcher Level 3
Switcher Level 4
Switcher Level 5
Switcher Level 6
Switcher Level 7
Switcher Level 8
Keyer 3 (internal logo source)
Keyer 4 (internal logo source)
Keyer 5 (internal logo source)
Keyer 6 (internal logo source)
DVE/Squeezeback engine
Voice-Over Mixer
Switcher Configuration in bus.tbl
To allow the IconMaster to receive switching requests for events on a specific bus, there must be a corresponding entry in the bus.tbl record to map the
D-MAS switching level on that bus to the IconMaster: (The switcher number field has the swr.tbl index of the IconMaster, and the output number field is set to 1).
Table 8-3. Mapping of bus.tbl switcher Fields to D-MAS Switching
Levels
bus.tbl field
Switcher number
DSK 1 switcher number
DSK 2 switcher number
DSK 3 switcher number
DSK 4 switcher number
Logo switcher number
Logo 2 switcher number
Audio over 1 switcher number
Audio over 2 switcher number
Effect switcher number
D-MAS switching level
A Audio and V – Video
D1 – Over Video 1
D2 – Over Video 4
D3 – Over Video 5
D4 – Over Video 6
L1 – Over Video 2 (aka L or Logo)
L2 – Over Video 7
O – Over Audio
O2 – Over Audio 2
E – Over Video 3 (aka Effect)
132 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 8: Automation Setup
Source Configuration in src.tbl
The internal logo store of the IconMaster (associated with keyers 3-6) can be controlled as a source by D-MAS. This allows D-MAS to control which internal logo is associated with each of these keyers. If no source control is configured for a particular internal keyer, then that keyer displays whatever logo was last configured manually.
Table 8-4. Settings in src.tbl for IconMaster Internal Logo Store Sources
(Keyers 3-6)
Field Value
Switcher number
Main source main audio input number
Main source main video input number
Source Type
Machine control type
Machine control index
Default control number
Ready time
Index of the IconMaster entry in swr.tbl
1
1
Source type associated with a specific sub-event used to map source to a keyer
(normally one of D1, D2, D3, D4, L1 or
L2). This should match the setting for corresponding “Switcher level n” entry for the keyer in swr.tbl (where n=3, 4, 5 or 6).
ICM
Index of the IconMaster entry in swr.tbl
11 (i.e. ready and start control)
A suitable time (a few seconds is ample)
Operation Notes
When the corresponding source entry is specified in the appropriate subevent, the corresponding material ID field accepts numeric entries between 1 and 999 to specify an internal logo from the IconMaster logo store (there is no checking to ensure a specific logo number actually exists).
At the ready time, a request is issued to load the specified logo number, unless the keyer is already active on the IconMaster’s PGM bus (in which case, the logo is not loaded until start time).
Configuration for Squeezeback and DVE Effects
The IconMaster supports up to 16 squeezebacks or DVE effects that are preconfigured (i.e. the details of the effect can not be controlled from D-MAS).
DVE transitions are not supported.
Note
Currently, only a single upstream router may be defined for the
IconMaster. Thus, if an IconMaster is using explicit routing for both program and effect sources, the program and effect sources must be on the same upstream router.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
133
Chapter 8: Automation Setup
The IconMaster has a dedicated DVE input; labeled “Squeeze Bkgd” on the breakout panel. A source may be directly connected to this input, or any of several sources may be routed to it if the IconMaster is configured to use an upstream router.
Table 8-5. Settings in swr.tbl for Explicit Upstream Routing of Effect
Sources
Field Value
1 1st effect input from upstream routing switcher
1st effect output on upstream routing switcher
The output number on the upstream switcher connected to the IconMaster’s
Squeeze Bkgd input.
Describing an Effect transition in ovrtrans.tbl
IconMaster effect subevent transitions are defined by entries in ovrtrans.tbl.
Table 8-6. Effect Transition Settings for IconMaster Entries in ovrtrans.tbl
Field Value
Custom Transition/Effect Number
Switcher Type
Transition/Effect Name
Description
Sequential, starting at 1 (not used by
D-MAS)
ICONMASTER
A name for the transition/effect. This value must be entered in the
EFFECT_TRANSITION field to initiate this effect. All transitions for the same switcher type must have unique names.
Text describing the effect (not used by
D-MAS)
DVE Transition?
“Squeeze and Reveal” (R) or Stretch and
Conceal (C)
Beginning DVE squeeze preset
N
Ignored for ICONMASTER (leave blank)
The predefined IconMaster effect to perform (an index between 1 and 16 inclusive)
The transition rate to use (S, M, or F) Beginning transition or DVE squeeze duration (mm:ss:ff or S/M/F)
Horizontal wipe on beginning transition?
Ignored for ICONMASTER (leave blank)
Vertical wipe on beginning transition?
Ignored for ICONMASTER (leave blank)
Reverse wipe direction on beginning transition?
Ignored for ICONMASTER (leave blank)
134 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 8: Automation Setup
Table 8-6. Effect Transition Settings for IconMaster Entries in ovrtrans.tbl (Continued)
Field Value
Ending DVE squeeze preset
Ending transition or DVE squeeze duration (mm:ss:ff or S/M/F)
Horizontal wipe on ending transition?
Vertical wipe on ending transition?
Reverse wipe direction on ending transition?
This should have the same value as the
“Beginning DVE squeeze preset” field
This should have the same value as the
“Beginning transition or DVE squeeze duration (mm:ss:ff or S/M/F)” field
Ignored for ICONMASTER (leave blank)
Ignored for ICONMASTER (leave blank)
Ignored for ICONMASTER (leave blank)
Number of transitions used in effect 2
Effect audio from background (on-air) or foreground (effect)
B (The
IconMaster
does not support audio from effect sources)
Audio transition is mix (foreground audio effects)
N (although not used by the
IconMaster driver, this field may not be left blank)
Audio transition rate (foreground audio effects only)
Over mix mixer (blank if not over mix)
Input A duck level (-100 – 0)
Ignored for ICONMASTER (leave blank)
Ignored for ICONMASTER (leave blank)
Ignored for ICONMASTER (leave blank)
Input B over level (0 – 28) Ignored for ICONMASTER (leave blank)
Time before transition to re-route video Ignored for ICONMASTER (leave blank)
Time between effects for DVE transition Ignored for ICONMASTER (leave blank)
Delay before starting 2nd background effect source
Ignored for ICONMASTER (leave blank)
Delay before starting 3rd background effect source
Ignored for ICONMASTER (leave blank)
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
135
Chapter 8: Automation Setup
Configuring IconMaster to Ignore Automation
Commands on Specific Key Layers
Note
This feature is supported in IconMaster (MKE) software release
2.2 and greater.
The IconMaster is designed to operate from a single point of control. Normally, this will be either the RCP remote control panel, or by automation. The
IconMaster does not support control by the RCP and automation independently at the same time. These devices can both control the IconMaster at the same time, however, and the IconMaster will operate as if the two control paths were one, using a single shared device.
To support the split use of IconMaster keyers between manual RCP operations and automation operations, the IconMaster can be setup to ignore automation commands for specific key layers. If this mode is configured, any automation commands which affect the ignored keyers will be ignored.
Setting Up Automation Key Masks
A key “mask” is a specific bit field in which each keyer is given a bit position, and the bit field is encoded to select which keyer layers will be respected by automation and which will be ignored.
• Bit 0 of the key mask is for Keyer 1 (first external keyer)
A value of 0 allows automation to control the keyer.
A value of 1 forces automation to ignore the keyer.
• Bit 1 of the key mask is for Keyer 2 (second external keyer)
• Bit 2 of the key mask is for Keyer 3 (first internal logo keyer)
• Bit 3 of the key mask is for Keyer 4 (second internal logo keyer)
• Bit 4 of the key mask is for Keyer 5 (third internal logo keyer)
• Bit 5 of the key mask is for Keyer 6 (fourth internal logo keyer)
The key mask is encoded as a byte, in the format 0xHH, where HH is the hex encoded key mask.
For example:
• A key mask of 0x00 (all zeros) is the default key mask, and will allow automation control of all keyers.
• A key mask of 0x0F will allow automation control of keyers 5 and 6, and will disallow automation control of keyers 1 through 4.
• A key mask of 0x30 will allow automation control of keyers 1 through 4, and will disallow automation control of keyers 5 and 6.
136 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Procedure
Chapter 8: Automation Setup
To set up a key mask in IconMaster, perform the following steps from a
MS-Windows computer connected to the same network as your IconMaster system:
1. Open a command prompt window by selecting the <Start> button at the bottom left of the screen. Select the RUN menu item, and then type cmd
in the field.
2. Press OK. A command prompt window will appear.
3. Begin a telnet session by typing telnet xxx
.
xxx
.
xxx
.
xxx
( xxx
.
xxx
.
xxx
.
xxx
= the IP address of the IconMaster's MKE-3901 module).
4. Type leitch
as the username.
5. Type
LeitchAdmin
as the password.
6. To display the current automation key mask, type getAutoKeyMask
, and then press <Enter>. The hex encoded key mask will be displayed, along with the IconMaster's interpretation of the code.
For example:
-> getAutoKeyMask
Auto Key Mask: 0x30
Displays the current hex encoded key mask
Bit 0 - Key1: 0
Bit 1 Key2: 0
Displays the status of keyer 1:
0 = keyer under automation
Displays the status of keyer 2:
0 = keyer under automation
Bit 2 Key3: 0
Bit 3 Key4: 0
Bit 4 Key5: 1
Bit 5 Key6: 1
Displays the status of keyer 3:
0 = keyer under automation
Displays the status of keyer 4:
0 = keyer under automation
Displays the status of keyer 5:
1 = keyer automation ignored
Displays the status of keyer 6:
1 = keyer automation ignored
Ignore the “value =” return line.
7. To set the current automation key mask, type setAutoKeyMask 0xHH
and then press <Enter>. (
HH
is the hex-encoded key mask [i.e.,
0x30
]. Include the
0x
[zero and x] characters when entering the hex number. Again, ignore the “value =” return line.)
8. To verify the current automation key mask, type getAutoKeyMask
, and then press <Enter>.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
137
Chapter 8: Automation Setup
9. To end the Telnet session, press <Ctrl> + ] (closing square bracket), and then type quit.
The following screen shows the above process, where the IconMaster begins with a key mask of 0x30 (masking/ignoring keys 5 and 6), and is changed to a key mask of 0x18 (masking/ignoring keys 4 and 5).
Figure 8-1. The getAutoKeyMask
Process
Important Considerations for Automation Key Masks
The most common reason for automation key masks is to allow the manual control of some key layers, while automating the remaining key layers.
It should be noted that the IconMaster is designed for single-user operation. The
“user” may be a manual operator using the RCP control panel, or it may be an automation system. The IconMaster system does not distinguish between manual and automation users.
When a user enables a key layer for the next transition, that layer is enabled regardless of which user initiates the next transition via the TAKE button or automation TAKE command. If a manual RCP user enables a key layer and the automation system enables a different key layer, the next TAKE will transition both keys.
138 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 8: Automation Setup
The issue listed above will only be a problem if manual operations are done at the same time as automated operations. The following simple, but effective, workaround should be followed to ensure that automated TAKE and manual
TAKE operations do not conflict.
All manual operations should follow these simple steps from the IconMaster’s
RCP control panel.
1. Press the HOLD button to disable automation control.
2. Verify only the keyers you wish to transition manually are enabled.
Normally, RCP keyer enables will follow automation control, so this step is important.
3. Press the TAKE button to perform the transition on only the selected keyers.
4. Deselect the key layers being controlled manually. This step is important, as the next automation TAKE operation will affect any keyers which are enabled for transitions.
5. Press the HOLD button to enable automation control.
Steps 1 and 5 above will safeguard against automation coming in while manual
operations are being set up and executed.
Automation Considerations
If a keyer is masked via the Automation Key Mask, the following automation commands will have no effect on the key layer:
• KEY_ENABLE
• KEY_MOD
0x0B
0x0A
• LOGO_SELECT 0x51
• LOGO_SELECT_KEY 0x71
Although the IconMaster will respond with ACKNOWLEDGE responses to these commands, the commands will be ignored by IconMaster. This has been done in order to avoid having automation systems invoke recovery procedures if they receive a NAK response.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
139
Chapter 8: Automation Setup
140 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 9
Configuring IconMaster
Overview
Harris’s IconMaster Configuration Utility, or ICU, software is an easy-to-use
Windows®-based application for setting up and configuring the IconMaster hardware system. It allows you to control configuration of input/output functions; audio, effects, and transitions; system components; and panel components through on-screen menu selections.
IMPORTANT! You may or may not have access to the ICU
software. If you do not, you must ask your system administrator to perform these operations for you.
•
“Installing ICU Software” on page 142
•
•
“Initializing IconMaster” on page 146
•
“Managing ICU Databases” on page 147
•
“Input/Output Group Settings” on page 150
•
“Functional Group Settings” on page 162
•
“Control Group Settings” on page 176
•
“System Config Group Settings” on page 184
•
“Panels Group Settings” on page 202
•
“Quick Configuration Quick Reference Chart” on page 207
This chapter presupposes that you are familiar with the layout of an IconMaster control panel. If you are not, please refer to your IconMaster Functional
Operation and Configuration Manual for more information.
Note
Changes made in the IconMaster Configuration Utility will not take effect on an IconMaster Switcher until the database has been uploaded to the IconMaster frame. See
for instructions.
The quick reference chart on
page 207 shows the control panel clusters, the
functions that fall within each cluster, and the IconMaster configuration utility dialog box that allows you to configure that particular function.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
141
Chapter 9: Configuring IconMaster
Installing ICU Software
In order to have a fully functioning IconMaster control panel, you must use ICU to configure it. Here are the steps involved in a full installation:
1. Check the system requirements (
)
2. Assemble the tools you’ll need (
3. Configure the PC display (
4. Install the IconMaster configuration utility from CD to PC (
)
5. Check the Ethernet connections (
6. Start the configuration utility application ( page 145
)
7. Adjust network settings ( page 146
)
8. Adjust the operating standard ( page 147
)
9. Adjust the system timing (
Default Configuration Files
For your convenience, several default configuration files are included on the
IconMaster SoftTools CD included with your IconMaster control panel. You can use and modify these files.
These files are set up for an SD-525i/59 bilevel sync:
• Default_SD_NSM_Embedded.xml
• Default_SD_NSM_Discrete2ch.xml
• Default_SD_Panacea_Embedded.xml
These files are set up for an HD-1080i/59 with trilevel sync
• Default_HD_NSM_Embedded.xml
• Default_HD_NSM_Discrete2ch.xml
• Default_HD_Panacea_Embedded.xml
These files are “getting started” databases for you to use if you do not have a router database already configured for your system:
• Pana16x4 SDIAES1.da4 (Panacea 16×4, SDI video with 1 AES audio)
• Pana16x4 SDIAES2.da4 (Panacea 16×4, SDI video with 2 AES audio)
• Pana16x4 SDIEMB.da4 (Panacea 16×4, SDI video with embedded audio)
• Pana16x8 SDI-CQ.da4 (Panacea 16×8, Clean/Quiet, SDI video with embedded audio)
• Pana16x16 SDIEMB.da4 (Panacea 16×16, SDI video with embedded audio)
• Plat64x64 SDIAES.da4 (Platinum 64×64, SDI video with 1 AES audio)
• Plat64x64 SDIEMB.da4 (Platinum 64×64, SDI video with embedded audio)
142 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 9: Configuring IconMaster
System Requirements
The following minimum requirements are necessary to operate IconMaster configuration software.
Table 9-1. IconMaster Configuration Software System Requirements
Item
CPU
RAM
Hard disk space
Additional disk drives
Operating systems
*
Specification
266 MHz Pentium II
At least 256 MB
At least 30 MB free
CD-ROM or CD-RW
Windows® 2000, Windows XP, and Windows
Vista, with Microsoft® Internet Explorer 5.0 or later
Display resolution 1024×768, high color (16 bit) or higher
Pointing device Mouse, trackball, touch screen, or other pointing device
*
Windows 2000, Windows XP, Windows Vista, and Microsoft Internet Explorer are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.
Tools You Will Need
• Icon Series SoftTools CD (P/N 178-000176-00)
• PC matching system requirements
Installing the IconMaster Configuration Utility
1. If an existing version of the IconMaster configuration utility is installed on the PC, uninstall it, and then restart the PC.
2. Close all other applications running on the PC and insert the Installation CD into the PC CD-ROM drive.
3. Double click Setup.exe if setup does not start automatically.
4. When the Welcome box appears, click Next.
5. When the Warning! box appears, click Next.
6. Accept the software license.
If you do not accept the license, installation will not continue.
7. If the Microsoft .NET framework box appears, follow the instructions, and then click Next.
8. When the Select Installation Type box appears, follow the onscreen instructions to install all four software applications (Content Editor,
LogoCreator, IconLogo SoftPanel, and IconMaster Configuration Utility).
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
143
Chapter 9: Configuring IconMaster
Figure 9-1. Selecting or Deselecting a Feature
9. When the Setup Complete message appears, click Finish.
Removing IconMaster Configuration Software
To remove IconMaster Configuration software:
1. Go to the Windows Control Panel (Start
→ Settings → Control Panel), and then select Add/Remove Programs.
2. Select Harris IconTools from the list.
3. Select Remove and follow the instructions provided on-screen.
CAUTION
Removing IconTools will also remove LogoCreator,
Content Editor, and IconLogo SoftPanel.
144 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 9: Configuring IconMaster
Ethernet Connections
IconMaster uses Ethernet-based communication. Default IP addresses will function correctly in a “one frame and one control panel” configuration if they are both connected to the same switch that is not connected to a network server/router.
IconMaster control panel
PC running
IconMaster configuration utility
Ethernet switch
NEO frame containing
IconMaster system
(MKE-3901, MGI-3903, and optional MKA -3901)
Figure 9-2. Simple Non-Network IconMaster Configuration
Starting ICU
To start the ICU application, select the IconMaster Configuration Utility icon by following this path:
Start
→ Programs → Harris → IconTools → IconMaster
The IconMaster configuration software main menu will display. The main window of the IconMaster configuration software provides a list of the main menu item groups. The groups that appear depend on whether you select frame configuration or panel configuration.
Configuring a PC Monitor for Best Display
For IconMaster software to show clearly and appropriately on a PC monitor:
1. Set the Display Properties for the monitor to 1024×768 pixel resolution (or larger) with regular or small fonts.
2. Go to the Start menu, and then select Settings
→ Control Panel →
Display
→ Display Properties → Settings.
3. Set the color palette to display either High (16-bit) or True (24-bit) color.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
145
Chapter 9: Configuring IconMaster
Frame Configuration Menu Groups
When you choose to create a new IconMaster Frame Configuration (File > New
> IconMaster Frame Configuration), four menu groups will appear. They are described in the following sections:
•
“Input/Output Group Settings” on page 150
•
“Functional Group Settings” on page 162
•
“Control Group Settings” on page 176
•
“System Config Group Settings” on page 184
Panel Menu Group
When you choose to make a new Control Panel Configuration (File > New >
Control Panel Configuration), one menu group will appear. For information on
this menu group, see “Panels Group Settings” on page 202
.
Initializing IconMaster
Once you have started the IconMaster configuration utility, you will need to make adjustments to the following settings:
• Network settings
• Operating standard
• System timing
Network Settings
The default IP address will function correctly in a “one frame and one panel” configuration if both frame and panel are connected to the same switch that is
not connected to a network server or router. However, if you are connected to a network server or router, you will need to coordinate the IP address for the
MKE-3901 module, the MGI-390x module, and/or the IconMaster control panel.
Notice that there are two different network settings selections within the main menu groups. One selection controls network settings for the frame (found in the System Configuration menu group), and the other selection controls the network settings for the control panel (found in the Panel Configuration menu group).
If you have changed the IP address on the card edge of the MKE-3901 module,
you must make the same change in the Network dialog box (see page 194
for more information on changing this setting).
To change the network settings of the IconMaster control panel, access the
Panel Network Configuration dialog box (see
on changing this setting).
146 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 9: Configuring IconMaster
Operating Standard
The default operating standard for IconMaster is SD525 (270Mbit/sec). To
change the operating standard, access the Genlock and Standard (see page 184
for more information on changing this setting).
System Timing
Changing the system timing causes the IconMaster system to adjust the horizontal and vertical phase of the reference input so that the most number of inputs have their vertical timing value at zero. To make changes to the
IconMaster timing, access the Genlock and Standard dialog box (see
page 184 ) to make changes to the IconMaster timing.
CAUTION
Do not do a system timing activity until the IconMaster has been downloaded with a valid configuration file with appropriately assigned primary inputs.
Unwanted on air operation may result.
Managing ICU Databases
Note
Instructions on enabling a router database for use with an
IconMaster system begin on
.
ICU uses XML databases to store configuration information about the different
IconMaster setups you develop.
CAUTION
If you do not want your changes to appear in the active
XML database, you should create a new XML database file before you make any changes.
You can create an ICU database from scratch or create one by opening an existing database, renaming it, and then manipulating existing information.
Creating an ICU Configuration File
1. Start IconMaster, as explained on
2. At the IconMaster Configuration Utility main menu window, select
File
→ New. The New Configuration dialog box will appear.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
147
Chapter 9: Configuring IconMaster
Figure 9-3. New Configuration Dialog Box
3. Select the appropriate radio button to set up the type of configuration file you want to create.
Table 9-2. New Configuration Types
Configuration
IconMaster Frame
Configuration
Control Panel
Configuration
Description
Specific configuration of inputs and outputs; transition, audio and effect buttons; machine control (including GPI/GPO); genlock; router management; automation; license management; serial port; and multiviewers
Specific configuration and panel network configuration functions
4. Depending on which selection you made in step 3, the applicable menu
options will appear.
5. Click File
→ Save As, and then enter a name for the new database.
6. Click Save. This will become the currently active database, and its name will be displayed in the Title bar at the top of the ICU main menu window.
Database files are saved in the Documents and Settings
→ All Users →
Application Data
→ Harris → IconMaster directory on your local drive.
148 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 9: Configuring IconMaster
Opening an Existing ICU Configuration File
Database files are saved in the Documents and Settings
→ All Users →
Application Data
→ Harris → IconMaster directory on your local drive.
CAUTION
ICU for IconMaster 3.1 has been tested for backwards compatibility with Iconmaster 1.5.3 and IConmaster 2.X configuration databases.
However, re-verify all configuration settings before applying them to the IconMaster.
It is strongly recommended that you back up your old configuration file before using a new 3.1 configuration file.
1. Start IconMaster, as explained on
2. At the IconMaster Configuration Utility main menu window, select File
→
Open. The Open A Configuration dialog box will appear.
3. Select a configuration file (XML file) from the displayed list. If the XML file resides in a different location, use standard Windows navigation techniques to move to the location of the file you want to display.
4. Highlight the name of the file you want, and then click Open.
Saving Databases
Saving to a New Database
1. From the menu bar, click File, and then select Save As. The Save As dialog box will appear.
2. In the File Name drop-down list box, do either of the following:
• Enter a name for the database that will hold the changes you just made.
• Highlight the name of an existing database (use standard Windows navigation procedures to select a location different from the default location). Be very careful doing this. Saving to an existing database will cause the software to overwrite the original database settings. It will not append your new changes to the existing database.
3. Click Save.
4. (Optional) Upload the effects to the IconMaster frame. See “Uploading
Databases” on page 149 for more information.
Uploading Databases
Changes made in an ICU dialog box will not take effect until the saved database has been uploaded to the IconMaster frame. To upload changes:
1. Save your current configuration file.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
149
Chapter 9: Configuring IconMaster
2. From the menu bar, click Send CFG to frame. An information message will prompt you to confirm the upload of the configuration to the
IconMaster frame.
3. Click Yes. The database will be uploaded to the IconMaster frame.
Most new settings will take effect on the IconMaster immediately. Changes that require a reboot include:
• Standard change (also requires new firmware)
• Upgrade license from IconMaster LITE to full IconMaster
• A change of serial port settings
• Changing an SD system from 8-channel audio operation to 16-channel audio operation
Input/Output Group Settings
The Input/Output group on the left side of the IconMaster configuration software screen includes the following dialog boxes: Primary Inputs, Audio
Configuration, Audio Over Matrix, and Aux Bus.
Figure 9-4. Input/Output Menu Group
This menu group controls system input and output configuration functions, as
.
150 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Primary Input Settings
Chapter 9: Configuring IconMaster
Figure 9-5. Primary Input Dialog Box
Using the Primary Input settings, you can perform the following actions:
• Change the names of your sources
• Manage router sources at the physical control panel (instead of always having to download a configuration from the ICU)
• Change the router source number
• Choose a preset quick select
• Enable Program Bypass
• Protect or unprotect the router A/B feeds to IconMaster
1
To change the Name of the input source, double-click the name in the cell, and then enter the new name. The length of the name is limited to 10 characters
(including spaces), over 2 lines, with a maximum of 5 characters per line.
1. The Protected option allows a router destination to be locked to prevent inadvertent changes to the A/B sources feeding the IconMaster. With the Protected feature enabled, only the IconMaster will be able to change the router destination at will, but other users will be prevented from changing that destination until the Protect is removed. The X-Y bus panel ID setting on the Router Configuration page must be set to a unique value.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
151
Chapter 9: Configuring IconMaster
To allow control panel router source management, click the Dynamic check box to the right of the router source number. If you have selected “12 inputs” as the primary input mode, you will be able to allow control of 12 sources. if you have selected “22 inputs” as the primary input mode, you can allow control of
22 sources. To set the primary input mode, you must use the System
Configuration dialog box. See
The Preset QS (Quick Select) assigns the sources you pre-configured in the
Quick Select Dialog Box (see page 169
) to a primary input. To choose a preset
quick select, click the Preset QS drop-down list box that corresponds to the appropriate router source number, and then scroll down to the appropriate quick select number. Use of preset Quick Selects is not recommended if the Auto
Take function of Quick Selects is enabled.
Note
The PGM Bypass option is not available on a system that does not include an IconMaster breakout module.
To enable the PGM Bypass option, click the check box to the right of the PGM
Bypass Input Bus selection.
When the PGM Bypass option is selected, IconMaster can control an auxiliary output from the primary router (the router output for bypass will be a separate output with the same content as the IconMaster PGM output for this to operate correctly) . This auxiliary output will follow the same source that is currently on-air. The router output can be linked to the IconMaster’s emergency PGM input and, in the event of an IconMaster failure or loss of power, a bypass relay will instantly connect the auxiliary signal to the IconMaster’s PGM output
BNC.
To protect router A/B feeds to IconMaster, click the Yes - Protected radio button. To unprotect the feeds, click the No - Not Protected radio button.
To prevent operators from protecting a Destination and then not being able to find the panel that originated the protect, Harris physical router control panels incorporate an override feature. To override a Destination Protect that was
set by another panel or IconMaster, press and hold the control panel Protect key until it stops blinking (about 5 seconds). At the end of the 5-second period the Destination Protect key will no longer be lit, which means that the destination is no longer protected. For more information about this feature, see the pertinent router control panel installation, configuration, and operation manual.
152 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 9: Configuring IconMaster
Audio Configuration Settings
Using the Audio Configuration dialog box in ICU, you can designate the audio output for each audio input.
Define audio profiles
Assign audio profiles
Figure 9-6. Audio Configuration Dialog Box
Note
The Audio Channel 8 Channels and 16 Channels selections are not available if the IconMaster has been configured for HD operation.
Audio Profiles
To simplify configuration of inputs with similar audio settings and correct wiring or mapping problems, IconMaster provides one default and 15 user-definable audio profiles. An audio profile is a set of audio input to output mappings, which can be applied to any input source.
In the Audio Routing Setup, all inputs are assigned the Default profile.
Profiles that have a check in the Enable column are available for assignment.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
153
Chapter 9: Configuring IconMaster
To edit a profile:
1. Select one of the user-defined profiles at the top of this screen.
2. (Optional) Click in the Audio Profile field and type a new name to rename the profile.
3. Select the primary audio input type. Options are:
• Embedded audio is recovered from the specific SDI input.
In an SD IconMaster system, as in
Figure 9-6 , under Audio Channel,
you can determine whether to use 8 or 16 audio channels. Then, for each primary audio input, each of the 8 or 16 audio input channels can be assigned to any or all of the 8 or 16 audio output channels.
Note
If the audio configuration for an SD Iconmaster is changed from 8 channel to 16 channels, or from 16 channels to 8 channels, you must reboot IconMaster to ensure that all audio channels are properly configured. After uploading the configuration file to the IconMaster, you can reboot the MKE using ICU's Reboot MKE button.
In an HD IconMaster system with embedded audio, as in Figure 9-7
, for each primary audio input, each of the 16 audio input channels can be assigned to any or all of the 16 audio outputs.
154
Figure 9-7. Audio Dialog Box — HD with Embedded Audio
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 9: Configuring IconMaster
• Discrete audio is available with the optional MKA-3901 audio module only. Discrete audio inputs are sample rate converted, and thus can only accept PCM audio.
Note
Due to sample rate converters, Dolby-E inputs via discrete audio are not supported by IconMaster.
In a HD IconMaster system with discrete audio, as in
each primary audio input, each of the 8 audio input channels can be assigned to any or all of the 16 audio outputs.
Figure 9-8. Audio Dialog Box — HD with Discrete Audio
If discrete audio inputs are used, all Audio Input Type settings should be manually assigned to either Processed or Unprocessed. The
Automatic setting is not applicable to discrete audio inputs.
4. Under Audio Channel, select either 8 or 16 channels.
As the audio configuration state changes from 8 to 16 (or vice versa), the
Audio Over Matrix and Audio Cluster dialog boxes will also change accordingly. See
page 175 for more information.
5. Edit the Audio I/O Mapping grid.
This audio mapping will only be applied to the specified input.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
155
Chapter 9: Configuring IconMaster
IconMaster can recover up to 16 audio channels from each of the 12
1
or 22
2 primary embedded inputs. Alternatively, if the MKA-3901 module is present, IconMaster allows for up to 4 AES inputs from each of the 12 or 22 primary inputs. Each of the AES inputs has 2 audio channels for a total of 8 audio channels for each input.
6. To rename an audio input, in the Audio I/O Mapping grid, double-click on the name of the input, and then enter a new name.
A maximum of 6 characters is allowed.
7. Under Audio Input Type, for each AES audio input select one of the following:
• Processed (default)—Full audio control is enabled. IconMaster ignores incoming C and V bits (see
), and full audio control is enabled.
Operators have full control of audio gain, channel swapping, sum, mono, etc. The output AES channel status (C and V) bits are forced to indicate valid PCM audio.
• Unprocessed—Audio is passed without modification (all audio settings are ignored). This is the required setting to pass non-PCM audio, such as Dolby
®
E encoder/ decoder
3
, through IconMaster.
full audio control is disabled. No gain or channel manipulation is allowed. The output AES channel status (C and V) bits follow the incoming channel status bits.
• Automatic (default)—IconMaster monitors the incoming C & V channel status bits. If the incoming channel status bits indicate Valid
PCM (C=0, V=0), then full audio control is enabled. If either channel status bit is set to 1, audio control is disabled. The output AES channel status bits (C and V bits) follow the incoming channel status bits.
Table 9-3. AES Channel Status Bits
Bit Function 0 1
Each AES channel pair includes two important channel status bits:
C Indicates whether the AES channel contains PCM sampled audio data
PCM audio, which can generally be gain adjusted, summed, swapped, mixed to mono, etc.
NON-PCM data, which should not be altered in any way.
V indicates whether the AES channel contains VALID data.
Valid data Invalid data
The following outlines some common data types, and their C & V bit settings:
C bit V bit
0 0
Meaning
Valid PCM
Typical Use
Normal audio
156
1. This is true for 12 input mode.
2. This is true for 22 input mode.
3. Dolby and the double-D symbol are registered trademarks of Dolby Laboratories.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 9: Configuring IconMaster
Table 9-3. AES Channel Status Bits (Continued)
Bit
1
0
1
Function
0
1
1
0
Valid Non-PCM
Invalid PCM
1
Dolby-E, data carried as audio
Audio with error (CRC, equipment, etc), which should NOT be converted to analog via D/A process.
Rarely seen Invalid Non-PCM
When changing the assignment from Processed to Unprocessed, all audio settings will return to their default values. When changing the assignment from
Unprocessed to Processed, all audio settings will be restored to the values currently set on the control panel.
Audio Over Matrix Settings
Figure 9-9. Audio Over Matrix Dialog Box
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
157
Chapter 9: Configuring IconMaster
The Audio Over Matrix dialog box includes the settings for the Audio Over inputs 1 and 2. Using this dialog box, you can assign the A/O inputs to the audio outputs and configure audio ducking.
IconMaster has 2 AES inputs dedicated to the audio overs. Each AES input has
2 audio channels. The number of outputs corresponds to the number of audio
channels selected at the Audio Configuration dialog box (see page 153 ). In an
SD system, each of the 4 channels can be assigned to any or all of the 8 or 16
Audio Outputs (depending on how SD audio is configured. See
HD system, each of the 4 channels can be assigned to any or all of the 16 Audio
Outputs.To change the assignment, select the check box that corresponds to the input/output combination required.
An audio output cannot be assigned to more than 1 audio input. An audio input can be assigned to more than 1 audio output.
The audio assignments can be different for A/O1 and A/O2.
As shown in Figure 9-9 , audio over channels 1, 2, 3, and 4 are defaulted to
Audio Outputs 1, 2, 3, and 4, respectively.
Audio over ducking can be configured differently for A/O1 and A/O2.
• If Duck All Audio Output Channels is selected, any audio output that is not assigned an audio input will “fade down” the background audio on that channel during an audio over.
• If Duck Only Output Channels with A/O Assigned is selected, only the audio outputs that are assigned an audio input will “fade down” the background audio and perform the audio over.
Note
Logo audio matrix settings are configured in the IconLogo soft gui tool. See the “Audio Menu Page” section of your IconLogo documentation for more information.
Aux Bus (Auxiliary Bus Configuration) Settings
The Auxiliary Bus Configuration dialog box ( Figure 9-10
) configures the
IconMaster auxiliary bus routing. This makes it possible to control additional router destinations with the Aux bus. The IconMaster control panel provides for the selection of 1 of 12 Aux buses.
158 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 9: Configuring IconMaster
Figure 9-10. Auxiliary Bus Configuration Dialog Box
Any destinations can be used for the Aux buses.
Configuring Aux Buses in Static Mode
When not in Router Database mode (see page 187
), follow these steps to configure the Aux Buses:
1. Select one of the Aux buses listed (1 through 12) from the Aux Bus drop-down list box.
The name associated with that Aux bus item will appear in the Aux Name box.
change the name(s) of the Aux bus configurations, double-click in the Aux
Name box, and then enter a new name for the aux bus (a maximum of 6 characters is allowed).
After the changes have been uploaded to the IconMaster frame, this name will appear in the LCD button that is on the extreme right side of the Aux bus. (See your Iconmaster Functional Operation and Configuration
Manual for the LCD button location.) If multiple Aux bus ports are assigned individual names (e.g., Aux 1 is renamed Aux A, Aux 2 is renamed AuxCtrl), you can toggle the Aux bus LCD button to scroll through the various buses. Any Aux buses labeled “Unused” will not appear on the LCD button display.
2. if it is not already selected, click the Enable checkbox.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
159
Chapter 9: Configuring IconMaster
Any aux buses that are not enabled will not appear in the LCD button display on the RCP, and will be grayed out in the ISCP.
The router source levels will be set automatically, to the defaults in
.
3. To change the name of a router source configuration, click on the appropriate name box, and then enter a new name for the associated source
(a maximum of 8 characters is allowed).
4. To change the level assigned to each Aux bus, click on the appropriate level box, and then choose the required level from the drop-down box. There is a maximum of 16 levels (0 to 15). Selecting Unused will disable an Aux bus from use.
5. The number in the Dest column should be set to the router destination being used for each of the Aux buses. To change the assignment, double-click on the Dest field to be changed, and then enter the new assignment. Press
Enter to complete the change.
Any router input can be assigned to any of the 12 Aux bus sources (labeled Src
1 to Src 12). This is possible for each aux bus independently. To change the assignment, double-click the Src field to be changed, and then enter the new assignment. Press Enter to complete the change.
Note
It is strongly encouraged that any Aux busses that are not in use be disabled using the Enable checkbox at the top of each Aux bus page, for Aux busses 1–12.
160 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 9: Configuring IconMaster
Configuring Aux Buses in Router Database Mode
To configure the Aux buses using an external router in Router Database mode
(see
page 187 for information), the Aux Bus dialog box will appear slightly
different, as in Figure 9-11 .
Figure 9-11. Aux Bus in Router Database Mode
To configure the Aux Bus in Router Database mode, follow the first three steps above, and then continue as follows:
1. For each input number, in the Router Levels row at the top of the grid, pick a level.
2. Pick a destination for that router source from the DEST row at the bottom of the grid.
3. In the Source Input grid, click a field to open a menu, and then click on an item in the router database.
The field updates with the destination information for that cross-point.
Repeat these steps as necessary to complete the grid. All unused fields in the grid should be set to Unused.
When you select a router that is not in the database, all the sources will be listed.
However, these sources will not have cross-points. To enter the cross-point, click Manual, and then type in the cross-point.
The label does not represent the cross-point. It is just there as a reminder.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
161
Chapter 9: Configuring IconMaster
Functional Group Settings
The Functional group on the left side of the IconMaster configuration software screen includes the following dialog boxes: Transition, Effects, Quick Select,
Audio Cluster, and Keyer.
Figure 9-12. Functional Menu Group
This menu group controls the functional configuration of the IconMaster, as
.
Transition Settings
162
Figure 9-13. Transitions Dialog Box
The Transition dialog box in ICU contains parameters that affect the operation of the buttons on the Transition Functions cluster (see your Master Control
Switcher Functional Operation and Configuration Manual).
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 9: Configuring IconMaster
Setting Transition Rates
Unless otherwise stated, the range is from 1to 300 frames.
Table 9-4. Transition Settings
Transition type
Video Frame Rate
Silent Transition rate
Fade to Black (FTB)
Transition Rate
Description/Option Default
Slow
Medium
30 frames
16 frames
Fast 8 frames
Cut (range from 0 to 300 frames) 1 frame
Fades out the audio at a faster rate than the video transition, to eliminate a distracting segue during the audio transition
10 frames
“Dissolves” a video picture to black
10 frames
Silence to follow FTB is normally used for transitions. With this option selected, the “fade to silence” during the video fade to black occurs at the rate you have set in the FTB Transition Rate. To enable this transition, select the
Silence to Follow FTB check box on the Transitions window. The default value is disabled (unchecked).
Setting Audio Transition Types
Note
The manual use of a cut button always overrides the selection on the Transition function bus.
The Audio Transition Type can be either V-Fade or Follow Video. Choose the appropriate radio button for your selection, as follows:
• Choose the default V-Fade selection to fade the first source to silence, and then fade up the new source. During this operation, the “V” button on the
Transition Functions bus is half-illuminated.
• Choose the Follow Video option to create a straight audio cross-fade.
Preventing and Enabling Closed Captioning
Select the VBI (vertical blanking interval) Closed Caption check box to prevent closed captioning on line 21 in 525 from being squeezed during an effect.
If the Closed Caption check box is not selected, the default value is line 20.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
163
Chapter 9: Configuring IconMaster
Effects Settings
164
Figure 9-14. Effects Dialog Box
Using the Effects dialog box in ICU, you can perform the following actions:
• Create an Effect
• Edit an Effect name
• Disable and/or re-enable an Effect
• Reset an Effect
• Set a second channel for preview operations
• Select a channel to edit
• Change a background source
• Change a crop size
• Change the position of a channel
• Change the squeeze ratio of a channel
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 9: Configuring IconMaster
Preloaded Effects in Default Configuration Files
For your convenience, several default configuration files are included on the
IconMaster SoftTools CD included with your IconMaster. These configuration files include the following preconfigured effects:
• Effect 1 = SQ-BRT, 1chl 35% window in upper right, with external background
• Effect 2 = SQ-BLT, 1chl 35% window in upper left, with external background
• Effect 3 = SQ-R, 1chl 75% H, 100%V on right side, with external background
• Effect 4 = SQ-L, 1chl 75% H, 100%V on left side, with preset background
• Effect 5 = SQ-URT, 1ch 75% L-Bar window in upper right with preset background
• Effect 6 = SQ-ULT, 1ch 75% L-Bar window in upper left with preset background
See
page 142 for a list of files that are included.
Before You Begin
Before you begin, ensure that you observe the following:
• Each effect should be viewed as a sequence of events, like a filmstrip.
• Each effect must be defined horizontally and vertically (the default position of 0,0 is defined as the upper left corner of the screen).
• All effects start with the Program full size. This is defined as Start A.
Note
For both single channel and 2 channel effects, the sequence will end with either Program as the only full size on-screen image.
For a single channel effect, do not select the Dual Channel Effect check box.
• Segment 1 defines the position and size at the end of the first transition.
• There is an entry only for Program.
• The background may be External Background or Preset.
• The end of the effect is set by Program.
For a single channel effect, the effect must end as a full-size Program or
Preset.
For a 2-channel effect, select the Dual Channel Effect check box.
• Segment 1 defines the position and size at the end of the first transition.
• There is an entry for both Program and Preset.
• The background may be External Background or Preset.
• The end of the effect is set by End A and End B.
• The effect must end as one of these options:
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
165
Chapter 9: Configuring IconMaster
• A full-size Program and a zero size Preset
• A full-size Program and a full-size Preset fully on screen.
• If you Preview Effect on PST in your effect, you can choose to preview the effect before you send it to air. If you select Dual Channel Effect, you cannot preview the effect before you send it to air.
Up to 16 different effects can be set up.
For an effect in SD, there may be potential discrepancies in horizontal and vertical blanking between analog and digital systems. It is recommended that a crop be added to the effect setup. IconMaster includes the following default values for the crop settings:
• Left 2
• Right 2
• Top 1
• Bottom 1
These default values prevent the appearance of a black border when the effect is underway.
Creating an Effect
An effect is made up of a sequence of events or segments. To create and store additional segments in your effect, click Add. Then, with the new segment number selected in the Segments field, you can modify what the effect looks like for that segment.
To create and store a multi-segment effect:
1. Double-click one of the cells in the Effects column, and then optionally, rename the effect (a maximum of 6 characters is allowed).
2. Select Segment 1 in the Segments field for the effect being edited. When a segment is highlighted in the Segments field, the squeeze and crop fields are enabled.
3. Select Enable Crop, and then make your required numeric settings (0 to
100) for Top, Bottom, Left and Right.
4. Set the destination of your Squeeze effect in the first segment by changing the percentage numbers in the Ratio and Position columns.
(Select Maintain Aspect Ratio if you need the horizontal and vertical values to be kept at a constant ratio.)
Note
Positions can be negative, for off screen positions above or to the left of the viewable screen area.
5. Click Add to create Segment 2 of your effect, and then select new values for Ratio and Position.
6. Continue for segments 3 and 4 as applicable.
166 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 9: Configuring IconMaster
Up to 4 segments are available for each effect.
The Reset button deletes all of the settings for the effect being edited. When you select the Reset button, a pop-up confirmation window appears, verifying that you want to reset the manual effect.
Editing an Effect Name
1. Under the Name column in the Effects box, double-click on the name of the effect you want to change.
2. Enter a new name for the effect (a maximum of 6 characters is allowed).
Enabling an Effect
Click the empty check box to the left of the name of the effect you want to enable. As a result, the Enabled check box will have a check mark in it to indicate the selected effect is enabled.
Disabling an Effect
Click the check box to the left of the name of the effect you want to disable. As a result, the Enabled check box will appear empty to indicate the selected effect is disabled.
Resetting an Effect
1. Highlight the effect you want to reset.
2. Click the Reset button at the bottom of the Enabled/name columns. An information message will “ask” if you want to reset the selected effect.
3. Click Yes. The effect will be reset to its default value.
Setting the Second Channel for Preview Operations
To use the second channel of the effects engine to preview effects on the Preset video output, select the Preview Effect on PST check box. The Background
Source will be forced to External Background and cannot be changed. In addition, the Preview will apply to all 16 effects.
The second channel can only be used in 1 mode; in other words, Dual Channel
Effect in the Channel section and Preview Effect on PST are mutually exclusive.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
167
Chapter 9: Configuring IconMaster
Selecting a Channel to Edit (Adding a Second Channel to an Effect to Squeeze the PGM and
PST Video)
To add a second channel to an effect to squeeze the PGM and PST video, select the Dual Channel Effect check box, select the Preset radio button, and then follow the procedure as described above. You can edit the effect after you have created it, by first selecting the appropriate channels box.
Changing a Background Source
Note
If Preview Effect on PST is selected, you will not be able to select a background source.
For each effect, the background source can be changed through the pull-down
Background Source box.
For a single channel effect, your choices are
• Preset
• External Background
For a 2-channel effect, when neither channel is full size, the Background
Source will be forced to External Background and cannot be changed.
Changing a Crop Size
1. In the Crop box, check the Enable Crop check box. The Left, Right, Top, and Bottom spin boxes will be enabled.
2. Enter the new percentage for each crop value. The range of values ranges from 0 to 100%.
Starting and Ending With a Background Transition
Place a check in the box to start or end with a background transition.
Changing the Position of a Channel
1. Select the appropriate segment in the Segments field for the effect being edited. When a segment is highlighted in the Segments field, the Position spin box is enabled.
1. Under the Squeeze
→ Position box, click the H (horizontal) or V (vertical) position box.
1
2. Enter the new percentage for the position value. The range of values ranges from -100% to +100%.
168
1. Position values always refer to the full, uncropped size.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 9: Configuring IconMaster
Changing the Squeeze Ratio of a Channel
1. Select the appropriate segment in the Segments field for the effect being edited. When a segment is highlighted in the Segments field, the Ratio spin box is enabled.
2. Unclick the Maintain Aspect Ratio check box.
3. Under the Squeeze
→ Ratio box, click the H (horizontal) and/or V
(vertical) box, and then enter a new ratio value(s). The range of values ranges from 0% to +100%. You can see a thumbnail view of the ratio of the squeeze on the Effects dialog box.
4. Under the Squeeze
→ Position box, click the H (horizontal) and/or V
(vertical) box, and then enter a new position value(s). The range of values ranges from -100% to +100%. You can see a thumbnail view of the position of the squeeze on the Effects dialog box.
Creating L-Bars
1. Select the appropriate segment in the Segments field for the effect being edited.
When a segment is highlighted in the Segments field, the Ratio spin box is enabled.
2. Under the Squeeze
→ Ratio box, click the H (horizontal) and/or V
(vertical) box, and then enter a new ratio value(s).
The range of values ranges from 0% to +100%. Setting the H value to 0 will set the L-bars to appear at the top left corner of the display. You can see a thumbnail view of the ratio of the squeeze on the Effects dialog box.
Creating Wipes
1. Select the appropriate segment in the Segments field for the effect being edited.
When a segment is highlighted in the Segments field, the Ratio spin box is enabled.
2. Under the Squeeze
→ Position box, click the H (horizontal) box, and then enter a position value of 100.
This value will cause a wipe effect on screen.
Quick Select Settings
Quick Select recalls the stored appearance of either the PST or the PGM monitor.
A Quick Select is a snapshot of the state of the various portions of your system.
The Quick Select dialog box has four tabs which allow you to select combinations of the following items:
• Both external keys
• Both audio overs
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
169
Chapter 9: Configuring IconMaster
• Logo Key 3 through Logo Key 6 states and/or contents (not available with
IconMaster Lite license)
• Aux bus functions
• Transition functions
To configure a Quick Select:
1. Choose whether you will recall the PST state or the PGM state.
Regardless of which state you will recall, the complete set of data is stored.
• Recall Saved PST State: Recalls whatever is on the Preset monitor at the time that the Quick Select is made
• Recall Saved PGM State: Recalls whatever is on the Program monitor at the time when the Quick Select is made
The PST/PGM state selection is a global selection that is made for all Quick
Selects.
2. Go through the four tabs of the Quick Selects dialog box, making selections for Quick Selects 1-8. Each row in the table represents a single Quick
Select.
Note
Each Quick Select can be named. The name assigned to a
Quick Select appears on the parametric Control cluster, on the
ISCP, and on any Quick Select button that is assigned on the
HRCP.
The contents of these tabs are described in the following sections.
•
“Quick Selects for External Keys” on page 171
•
“Quick Selects for Internal Logo Keys” on page 171
•
“Quick Selects for Aux Buses” on page 173
•
“Quick Selects for Transitions” on page 173
By default, all options on these tabs are selected, except for the Auto Take option on the Transitions tab.
3. When you are satisfied with your Quick Selects choices, save and upload to your IconMaster frame.
Back at your Control Panel, after the revised ICU file has been uploaded, when you store and recall Quick Selects, the snapshots that are captured will reflect the settings made on these screens.
170 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 9: Configuring IconMaster
Quick Selects for External Keys
The External Keys tab of the Quick Select Configuration dialog box has options for recalling both the visual and audio portions of the two external keyers.
Figure 9-15. External Keys Quick Select Dialog Box
When you enable External Keys selections, you recall the state of the settings assigned to the keyer at the time the quick select was saved. You can enable or disable selected keyers, which will remove those keyer functions from the corresponding quick select.
When there is a check mark for Ext Key 1 and Ext Key 2 for a Quick Select, that quick select will store and recall the visual conditions of that keyer, including its transparency, screen location, etc.
When there is a check mark for Ext A/O 1 and Ext A/O 2 for a Quick Select, that quick select will store and recall those external audio overs.
Click Select All to select both external logo keys and both audio overs on that
Quick Select. Click Select All again to unselect all components of both external logo keys and both audio overs for that Quick Select (row).
Quick Selects for Internal Logo Keys
Each of the four internal logo keys can have its state and/or its content saved as part of a Quick Select.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
171
Chapter 9: Configuring IconMaster
Note
If you have an IconMaster Lite license key, options for Internal
Keys will be unavailable.
172
Figure 9-16. Logo Keys Quick Select Dialog Box
For Logo Keys 3- 6, you can choose to store and then the the state and/or content as part of the Quick Select. Selecting the Select All box will store state and content for all keyers for that quick select.
Table 9-5. Settings for Each Internal Keyer
Keyer Setting
Keyer (3 - 6) state
Keyer (3 - 6) content
Function
Whether the keyer is on or off
The Logo #, Transparency, processing, etc. that are applied to that internal keyer
Select All will select all internal logos for that quick select. Each of the check boxes in the quick select row indicated whether the function listed at the top of the dialog box will be recalled during that quick select operation.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 9: Configuring IconMaster
If you select the Allow On-air Changes to Keyers check box, when the data stored in this Quick Select is recalled, the keyers will be updated on the PGM monitor. If this check box is not selected, Then when the Quick Select is recalled, the contents of the keys that are currently on the PGM monitor will not change. This will not change the state of the keys, though, and the keys can still come off air. This setting is a global setting that applies to all Quick Selects, for example to protect station branding.
Quick Selects for Aux Buses
For each Quick Select, you can choose to recall the contents of any or all of the
12 Aux buses.
Note
To avoid excess router switching traffic during a quick select recall, deselect all unnecessary Aux busses in quick selects that are in use.
Figure 9-17. Aux Bus Keys Quick Select Dialog Box
Click Select All to select all the Aux Buses for that particular Quick Select.
Click Select All again to unselect all the Aux Buses.
Quick Selects for Transitions
The Transition tab of the Quick Select Configuration dialog box has options
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
173
Chapter 9: Configuring IconMaster
174
Figure 9-18. Transitions Quick Select Dialog Box
By selecting a Transition check box, you recall the state of the transition settings, as described in
.
Table 9-6. Quick Selects Options for Transitions
Quick Select Option
Background Transition
Background Source
Effects
Transition Rate
Transition Type
Saves and recalls the state of the BKGD button on the control panel
The source that is on the Preset bus (whether the background is on or off)
All effects that are set on the transition
The preset duration for transitions
The shape of the transition
Click Select All to enable all transition features for that quick select. Click
Select All again to unselect all transition features for that Quick Select.
If Auto Take is selected, when the Quick Select is recalled to the PST, and a take is activated to send the PST content to the PGM. The previously shown
PST content is not preserved. If Auto Take is not selected, you can achieve the same effect by pressing Take on the Control Panel.
Note
A breakaway transition cannot be saved in a Quick Select.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Audio Cluster Settings
Chapter 9: Configuring IconMaster
Figure 9-19. Audio Cluster Dialog Box
1
An Audio Cluster is a group of audio channels whose gain can be adjusted as a group. A cluster can have up to 16 audio channels. The number of outputs corresponds to the number of audio channels selected at the Audio
Configuration dialog box (see page 153
). Typically, a cluster is a grouping of similar audio channels, such as MAIN+SAP or SURROUND (6 channels).
In the Audio Cluster dialog box, you can setup up to 8 audio clusters by selecting the audio channels you wish to group together. A specific audio
channel can appear in more than one cluster. (For example, in Figure 9-19 audio
channels 3 and 4 appear in the Clust2 clusters; audio channels 7 and 8 appear in the Clust4 clusters.) The cluster name can be edited by selecting the name field, and then typing a new name.
The default setting is for an audio cluster to be the same as an AES audio channel pair. This means cluster 1 is AES channel pair 1, cluster 2 is AES channel pair 2, etc.
Audio Cluster gain is adjusted directly from the IconMaster RCP control panel’s optional audio control panel.
1. This dialog box is for use with the optional IconMaster audio control panel.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
175
Chapter 9: Configuring IconMaster
Keyer Settings
The Keyer dialog box allows you to give a name to the external keyers. These names are displayed on the keyer LCD displays of the RCP control panel.
Figure 9-20. Keyer Dialog Box
Changing a Keyer Input Source Name
To change the Name of the input source, double-click the name in the cell, and then enter a new name. The length of the name is limited to 10 characters
(including spaces), over 2 lines, with a maximum of 5 characters per line.
Control Group Settings
The Control group on the left side of the IconMaster configuration software screen includes the following dialog boxes: Machine Control and GPI-GPO.
Figure 9-21. Control Menu Group
This menu group controls the machine control and GPI-GPO configuration
functions, as shown in Figure 9-21 .
176 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 9: Configuring IconMaster
Machine Control Settings
The Machine Control dialog box allows you to set the appropriate control functions for automation.
Figure 9-22. Machine Control Dialog Box
Using the Machine Control functions, you can perform the following actions:
• Coordinate GPI/GPO and machine control events
• Select the automation type
• Select the machine control settings
• Temporarily disable selected machine control settings
The Source column indicates the selected source. This column is read-only; you cannot make changes here.
The Name column indicates the selected sources’ name. This column is read-only; you cannot make changes here.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
177
Chapter 9: Configuring IconMaster
Configuring GPI/GPO Events to Machine Control
If you configure GPI or GPO events to machine control, you must ensure both
GPI/GPO and Machine Control settings are set up correctly. See
for the coordinating GPI-GPO and Machine Control settings.
Note
GPOs and GPIs can use the external interfaces. When using an external interface, 48 additional GPOs and 48 additional GPIs are available.
Figure 9-23. Coordinating Machine Control and GPI/GPO Settings
Selecting Automation Types
The Type column indicates if the input you have selected (1 through 12) will trigger GPOs (GPI Outputs), Serial protocol, or—through the Disabled option— normal functionality of the selecting source. The GPO configuration is common for all input types. If you have selected a GPO that is already configured in the GPI-GPO dialog box, a message will warn you that this action will affect the settings of your previously configured GPO.
178 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 9: Configuring IconMaster
The GPO option offers sources 1 to 13 and the Serial offers device IDs 0 to 31.
When Serial is selected, the Device ID value becomes the same for all functions.
Selecting Machine Control Settings
If you have selected GPO or Serial as automation type, the Machine Control columns (Play, Stop, Cue, Mark, Blank, Rewind, and Fast Forward) are enabled, and you may select values from the drop-down list boxes.
Disabling Machine Control Settings
Select the Disabled check box to temporarily disable any Machine Control settings you have made. (This is the default setting for the Automation Type.)
Preroll Functions
Using the Preroll functions, you can perform the following actions:
• Enable the preroll status
• Set or reset the preroll duration
Enabling Preroll Status
The Enabled check box enables the preroll status for that output. If you select
Enabled, but have Disabled selected under Type, no action will occur.
Setting/Resetting Preroll Duration
The Preroll Duration (Frames) sets the duration of the preroll from 0 to 600 frames. The default value is 60.
To make all of the preroll times match the preroll time of the selected item, press
Set All Durations Equal to Current Record’s Duration.
Note
If dynamic router control is selected for the Primary Input, then
Machine Control is not allowed for that input.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
179
Chapter 9: Configuring IconMaster
GPI Settings
To use external GPIs, you must first enable them on the ICU Network page (see
page 194 ), and configure the JLCooper eBOX (see their documentation for
details).
Note
If configuring an IconMaster LITE, fewer GPI and GPO selections are available. IconMaster LITE has 8 GPI and 7 GPO.
Adding a GPI
180
Figure 9-24. GPI Settings Dialog Box
Using the GPI dialog box, you can perform the following actions:
• Add or delete a General Purpose Interface input (GPI)
• Assign a trigger to a GPI source (GPI sources are assignable to Quick
Selects, Bus selections, and different transition types and rates)
• Coordinate GPI and machine control events
• Specify polarity of the GPI
• Set up the trigger function
• Choose what interface the GPI comes from
To add a GPI:
1. Click Add GPI at the bottom of the GPI dialog box.
A new row appears in the GPI table.
2. Click the GPI Number field to open a drop-down menu, and then choose a
GPO.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 9: Configuring IconMaster
3. Click the Assignment field to open a drop-down menu, and then choose one of the many possible triggers.
Table 9-7. GPI Assignment Options
Options
Disabled
PGM input (1 - 12)
Video Trans X Fade
Video Trans V fade
Video Trans Cut Fade
Video Trans Fade Cut
Video Trans Rate
Preroll Button
FTS Button
Key to Air
BKGD Button
A/O (1 - 2) Button
PST input (1 - 12)
Audio Trans X Fade
Audio Trans V Fade
Audio Trans Cut Fade
Audio Trans Fade Cut
Audio Trans Rate
Take Button
FTB Button
AO to Air
Key (1 - 6) Button
Quick Select (1 - 8) Button
Any changes you make to each GPO Assignment drop-down menu automatically are reflected in the GPO drop-down box in the Keyer dialog box.
Note
Key to Air and AO to Air are new GPI functions in IconMaster 3.1.
They allow a keyer or Audio Over to be active on air as long as the
GPI is active. These are recommended for use with EAS systems, where the EAS alert system can drive a GPI on the IconMaster to enable the Audio Over content coming from the EAS system.
4. Type a source in the SRC field.
5. In the Polarity column, set the GPO to Open or Closed.
6. Set the trigger function.
• For GPI 1-8 set the Trigger setting to Edge or Level.
• For GPI 9-18 the Trigger setting can only be set to Edge.
The examples below provide a scenario where a GPI source is used to select between 2 assignments (A and B):
• If Open polarity is used for the Level option:
• When the Polarity = Closed (not set) and Trigger = Level, select source A.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
181
Chapter 9: Configuring IconMaster
• When the Polarity = Open (set) and Trigger = Level, select source
B.
• If Open polarity is used for the Edge option:
• When the polarity changes from Closed to Open and Trigger =
Edge, switch from source A to source B. Nothing happens when the polarity changes back from Open to Closed.
• When the polarity changes again from Closed to Open and Trigger
= Edge, switch from source B to source A. Nothing happens when the polarity changes back from Open to Closed.
Deleting a GPI
To delete a GPI, highlight the entry you want to remove, and then click the
Delete GPI button.
GPO Settings
To use external GPOs, you must first enable them on the ICU Network page
), and configure the JLCooper eBOX (see their documentation for details).
182
Figure 9-25. GPO Settings Dialog Box
Using the GPO (GPI out) dialog box, you can perform the following actions:
• Add or delete a General Purpose Interface output (GPO)
• Name a GPO
• Assign a trigger to a GPO source
• Specify the polarity
• Set the duration
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 9: Configuring IconMaster
Setting Operation Precedence
If an IconMaster GPO is assigned on the GPO page of ICU, it will take precedence over the GPO operations if the same GPO is assigned to an RCP soft
LCD button. In this case, the RCP soft LCD button will have no effect. Thus, if you wish to assign a GPO to an RCP soft LCD button, the GPO’s setting on the
GPI-GPO page of ICU should be set to Disabled.
Adding a GPO
To add a GPO:
1. Click Add GPO at the bottom of the GPO dialog box.
A new row appears in the GPO table.
2. Click the GPO Number field to open a drop-down menu, and then choose a
GPO.
3. Enter a logical name in the Name column.
This name will be shown on the RCP panel, remind operators what the GPO will do.
4. Click the Assignment field to open a drop-down menu, and then choose one of the many possible triggers.
Any changes you make to each GPO Assignment drop-down menu automatically are reflected in the GPO drop-down box in the Keyer dialog box.
5. Click the SRC field to open a drop-down menu, and then choose a source.
6. In the Polarity column, set the GPO to Open or Closed.
7. In the Duration column, type the duration of the GPO.
The maximum duration is 900 ms. To have the GPO stay on, leave the
Duration cell empty or set it to 0.
If you configure GPO events to machine control, on the Machine Control dialog box, you must ensure that machine control is enabled for that GPO is enabled under the Type column, and that Preroll is Enabled for sources that have a GPO trigger assigned. See
page 177 for more information.
Deleting a GPO
To delete a GPO, highlight the row you want to remove, and then click Delete
GPO.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
183
Chapter 9: Configuring IconMaster
System Config Group Settings
The System Config group on the left side of the IconMaster configuration software screen includes the following dialog boxes: Genlock and Standard,
Router Configuration, System Config, Automation Config, Network, License
Manage, Serial Port, Multiviewer, and Clock and Timer.
Figure 9-26. System Configuration Menu Group
This menu group controls the genlock/standard, router, system, automation, network, license management, serial port, clock and timer, and multiviewer
configuration functions, as shown in Figure 9-26 .
Genlock and Standard Settings
The Genlock and Standard dialog is a very specific function dialog box. Using this box, you can perform the following actions:
• Select an operating standard
• Select a genlock source type
• Set the timing for the IconMaster system
184 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 9: Configuring IconMaster
• Get the timing report for the IconMaster system
Figure 9-27. Genlock Dialog Box
Selecting an Operating Standard
To select an operating standard, select the required standard from the Operation
Standards pull-down menu.
Selecting a Genlock Source Type
Select either Composite or Tri-Level from the Genlock Source Type pull-down menu. The default Genlock Source Type is Composite.
Adjusting the IconMaster System Timing
Note
Do not initiate a timing setup until all source inputs and destinations have been assigned in the primary inputs page, the appropriate configuration file has been applied to the IconMaster, and all input signals are applied and stable.
1. Press the Set Auto-Timing Operation button, and then click Yes after confirming all keyers are in an off-air state.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
185
Chapter 9: Configuring IconMaster
This action causes the IconMaster system to adjust the horizontal and vertical phase of the reference input so that the most number of inputs have their vertical timing value at zero. The results of this function are not displayed in the Timing Results area. Ensure that the external keys are taken off-air before you run the Set Timing procedure.
2. Allow the Timing operation to run for 1 minute.
3. Press the Get Auto-Timing Results button to retrieve the new timing reading from the IconMaster.
Note
The system phase values let you know how much the reference input had to be delayed so that the video inputs would be within a 1 video line of the reference input.
The Get Timing results are not a real-time indication of each input's timing offset. If an input's timing has changed, you must activate Set Timing again to retrieve the current results.
These results will be displayed in the Timing Results area. If external keys are on air when the Timing operation is initiated, the Timing results will show an error message, indicating that the timing setup was not run, and that the external keys must be taken off-air before Set Timing is run again.
4. Adjust the V phase timing for any source that is reported as not timed.
For example, if, after executing the Set Timing and Get Timing commands, you read a V phase value that equals 50, reduce the V phase timing of that input source by 50 lines.
5. Repeat steps 1 to 4 after adjusting the V phases of the sources, until all of the V phase values for the inputs are zero (i.e., the system is fully timed).
186 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Router Configuration Settings
Chapter 9: Configuring IconMaster
Figure 9-28. Router Configuration Dialog Box
The Routing Configuration dialog box (
) is used to set up the type of router which IconMaster uses as its primary source router.
• Router Mode
If the IconMaster is configured with NSM type NEO module routers, select the Internal (NSM) Router setting. If any type of external router is used
(Panacea, Integrator, Platinum, or third party), select External Router.
• External Router
Choose either of the following:
• Select Serial Port if you have a serial connection between the
IconMaster and the router.
• Select Ethernet if you have an Ethernet connection between the
IconMaster and the router. When you choose this option, the selections for a router name and the IP addresses for primary and secondary controllers will become available.
• If Ethernet is selected, serial port E is automatically released, and a pop up appears from ICU.
In circumstances when you have primary and secondary router addresses configured, failover will take place.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
187
Chapter 9: Configuring IconMaster
• Router Database
If the IconMaster is configured with static inputs (router sources are assigned to IconMaster inputs, without the operator ability to change the router assignments), then do not use the Router Database settings. However, if you wish to use the dynamic routing features of IconMaster, or to use an existing router database to select your IconMaster sources (regardless of
Dynamic Routing use), select the Using Routing Database checkbox.
• Selecting Sorted will optionally sort the router database alphanumerically.
• If Using Routing Database is selected, you will need to create a router database and then send this database to the IconMaster through the
Navigator application.
You cannot use the native RouterMapper DA4 database; you must convert it into an XML format through CCS Navigator™. See
for detailed instructions.
• Set the value in the Router Transition Delay spin box as appropriate for your router.
• The router transition delay can be a value between 1 and 15. For Platinum routers, typically a value of “5” is required. With most other routers, the default setting of “1” will suffice. Assessment of the performance of your channel release system should be performed to ensure that the router transition delay meets your station’s requirements.
188 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
System Configuration Settings
Chapter 9: Configuring IconMaster
The 22 Inputs option is grayed out because “External
Router” is set to No on the
Router Configuration page.
.
Figure 9-29. System Configuration Dialog Box
The System Configuration dialog box includes settings for various IconMaster system parameters, each of which is detailed below.
• Processing Priority
The Processing Priority settings affect how the IconMaster routes internal video and audio signals. Keyer priority settings can be changed using the drop-down boxes in the A/V Path group. The FX priority can also be assigned.
The IconMaster has a separate Clean output which can be assigned as well.
The video and audio pick positions for the Clean output can be set in the
Processing Priority settings.
• If the Disable FX checkbox is checked, the IconMaster FX squeezeback effects engine will be disabled.
• Primary Input Mode
This setting affects whether 12 or 22 primary inputs are available to
IconMaster.
• If 12 Inputs is selected, the 12 primary source input buttons will select between all available input sources.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
189
Chapter 9: Configuring IconMaster
• If 22 Inputs is selected, the primary source buttons will be split into one group of inputs numbered 1 – 11, and another group numbered 12 –
22. The far right primary source button will be used as the SHIFT button. When set to 22 Inputs mode, the SHIFT button toggles between 1 – 11 and 12 – 22.
Note
It is strongly suggested that you retime the IconMaster system if you change from 12 to 22 input mode. This will ensure the additional 10 inputs are correctly timed into IconMaster. See
page 184 for information on setting the timing for an IconMaster
system.
•
Fast Reset Behavior
This setting allows you to quickly reset audio gain and/or PROC parameter settings for an IconMaster input source, internal or external keyer, Audio
Over, or audio control item on the Audio Control Panel.
There are three separate operations that are enabled when the Fast Reset function is selected: SET, CLEAR, and RECALL. If the SET function is enabled, the parameter will not be reset, but its current value will be saved as the source’s user-saved reset value. This is the value that will be used during a RECALL operation. If the CLEAR function is enabled, the user-saved reset value will be cleared (back to factory value), and the keyer’s parameters will also be reset back to this factory value. If the
RECALL function is enabled, the user-saved reset value set up through a
SET operation will be applied.
Reset values can be either a factory reset values (0 dB gain, and default keyer values), or can be user-saved reset values, which are saved on a source-by-source basis for audio gains and on a keyer-by-keyer basis for keyer settings.
•
If Audio Gain + Proc is selected, the IconMaster will reset the audio gains of the selected source or audio configuration item to unity. It also resets all PROC audio input parameters to their original default values.
• If Audio Gain is selected, the IconMaster will reset the audio gains of the selected source or audio configuration item to unity, but it will not reset any of the PROC audio input parameters.
• When fast resetting a keyer, all keyer parameters will be reset to their defaults.
• When fast resetting an Audio Over, the Audio Over mix ratio will be reset to 50/50.
• Take Button
This setting affects the system behavior when the TAKE button is pressed during a transition.
190 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 9: Configuring IconMaster
• VANC Data in FTB
This setting affects whether the PGM output includes VANC data from the
PGM input source when the system is in the Fade to Black mode.
• PGM Bus Hot-Punch
This setting defines what the IconMaster will do when a PGM bus source is hot-punched. By default, the IconMaster will drop all keys, audio overs, and all effects. By un-checking these settings, the IconMaster can be configured to retain the on-air keys, audio overs, and effects in progress.
• EAS Audio
These settings affect how IconMaster responds to EAS (Emergency Alert
System) triggers received.
• If set to None, no audio will be altered during an EAS event.
• If set to On Audio Over 1 or On Audio Over 2, the selected audio over keyer will be turned ON during an EAS event, and turned OFF when the event completes. The Ratio setting adjusts the A/O ratio for the selected AO keyer during the EAS event.
Note
Use of On Audio Over 1 or On Audio Over 2 as part of an EAS event may result in an undesired on-air operation if the EAS receiver terminates the EAS message to the IconMaster before the completion of the EAS audio message. Consider using a GPO from the EAS receiver, connected to a GPI using the Key Enable
GPI function to maintain an active Audio Over while the EAS receiver is transmitting the EAS audio message.
• Audio Over Ratio Behavior
This setting allows you to specify the way the audio over ratio is interpreted by IconMaster. The default value for Audio Over ratio is 50%, which means full level mix for both AO and PGM. The 50% or 100% mix also applies to
Logo Audio Overs.
•
If 50% Mix is selected as a mode of operation, at 50% ratio the Audio
Over and PGM audio each make up 50% of the mix, and the level of each will be -3 dB.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
191
Chapter 9: Configuring IconMaster
100%
Audio Over
50%
PGM
0%
0% 50% 100%
Audio Over Ratio
Figure 9-30. Audio Over Ratio in 50% Mix Mode
• If 100% Mix is selected as a mode of operation, at 50% ratio the mix will be 100% of Audio Over and 100% of PGM, and will decrease respectively as you move “left” or “right” of the 50% mark.
100%
Audio Over
50%
PGM
0%
0% 50% 100%
Audio Over Ratio
Figure 9-31. Audio Over Ratio in 100% Mix Mode
192 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Automation Configuration Settings
Chapter 9: Configuring IconMaster
Figure 9-32. Automation Configuration Dialog Box
The Automation Configuration dialog box allows you to choose between logical IconMaster inputs or physical router inputs.
When you select Logical IconMaster Inputs, the Automation system will only be able to switch PST and PGM bus inputs that have been assigned (through the
Primary Input dialog box) to inputs 1 to 12 or 1 to 22 (depending on your configuration).
When you select Physical Router Inputs, you can switch unassigned sources directly from a router to any four IconMaster PST and PGM bus inputs ranging from 1 to 12 (or 1 to 22) that you will select from the Dynamic Inputs to Use drop down list boxes. When you select an input, IconMaster will check to see if that particular input has been assigned already to any of the PGM or PST bus buttons. If not, it will assign your source the to first, or top left, drop-down input box, which corresponds to inputs 1-12 (or 1-22) on the PGM or PST bus.
Currently, Asynchronous Status Reporting and Automation Log are not supported.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
193
Chapter 9: Configuring IconMaster
If you want the automation system to change sources even while under hold, place a check beside Update while in hold.
Network Settings
194
Figure 9-33. Network Dialog Box
The Network dialog box contains the network address settings that are necessary for the ICU program to communicate with the IconMaster’s
MKE-3901 module, and for the MKE-3901 to communicate with IconMaster’s
RCP control panels. It also contains selections for external interface devices
(such as the JLCooper Electronics eBox® Quad Serial to Ethernet Interface
1
) and their corresponding network address settings.
You can rename each frame that contains IconMaster components by clicking in the Iconmaster Channel Name field, and then typing the new name. A maximum of 8 characters is allowed for a host name.
The default network IP address of the IconMaster’s MKE-3901 module is
192.168.100.252.
• If this address has not been changed on the MKE-3901 module, then this setting should not be changed.
• If you have changed the IP address of the MKE-3901 using the module’s card-edge display, enter the new IP address in the IP Address field.
1. eBOX is a trademark of JLCooper Electronics.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 9: Configuring IconMaster
If you are communicating correctly with the MKE-3901 module, and wish to change the IP address using the ICU software, select the New IP
Address checkbox, and then enter a new IP address in the field to the right.
The Subnet Mask and Gateway settings can also be set in this way.
Note that after changing the MKE-3901 module’s IP address, you will need to power cycle the IconMaster's MKE-3901 module, and put the new address into the IP Address field above.
You can connect to two external input/output devices through the boxes labeled
External IO 1 and External IO 2.
1. Select the Enable External IO Module checkbox, and then select the external device type from the drop-down list box.
2. In the corresponding list boxes, enter an IP address and a port number for the external device.
3. (Optional) Enable the External IO Admin Password checkbox, and then enter the appropriate system administrator pasword.
If the External IO 1 or External IO2 is enabled, additional GPO and GPI
functions will become available in the GPO and GPI pages on page 180
and
See the JLCooper instruction manual for information on configuring the eBox for use with IconMaster.
License Management Settings
The License Management dialog box contains information about license keys installed on your IconMaster systems.
Figure 9-34. License Management Dialog Box
There are two licences for Iconmaster. The first licence enables Iconmaster to integrate with multi-viewers. the second licence option enables the INTERNAL keyers functionality of the Iconmaster, if an MGI3902 or MGI3903 board is installed.
To add a license key:
1. In the License Management dialog box, click Get License.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
195
Chapter 9: Configuring IconMaster
The IconMaster Serial Number field updates. If a license key is currently installed on the MKE-3901 board, the License Key field also updates.
2. Provide the IconMaster serial number to your Customer Service representative.
There are two ways to provide the serial number and receive your license key:
• By phone: Contact your Sales representative.
• By faxing or mailing a form to Harris: This form is available by clicking License Form. The form includes information on where it should be sent. (Acrobat Reader is required.)
3. Enter the provided key in the License Key field.
Your license should be recognized immediately. You must restart the
IconMaster frame when the system is converted from IconMaster Lite to
IconMaster.
Serial Port Configuration Settings
Note
The JL Cooper external interfaces include configuration options for
RS232 or RS422 operation, and are configured on the external interface, not within ICU.
196
Figure 9-35. Serial Port Configuration Dialog Box
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 9: Configuring IconMaster
The IconMaster currently supports several serial port direct connections; however, you can expand the number of available serial ports with the
ICONM-BO-V video breakout module (described in
Breakout Module” on page 43 ) or an external interface device such as the
JLCooper eBox. The Serial Port Configuration dialog box allows you to reassign the serial ports’ functions. If the Serial port baud rate, bits, parity or stop bits are changed, the IconMaster will require a restart.
PGM Out A/O 1
RS232-A RS232/422-B
AES
ICONM-BO-V Video Breakout
ICONM-BO-VAB Audio Balanced Breakout
RS232/422-C RS232-D RS232/422-E
Emerg In 1 A/O 2
Figure 9-36. ICONM-BO-V Serial Ports
Note
Because of real-time response considerations, certain functions will always be assigned to ICONM-BO-V serial ports C and D. You cannot change the functions for these ports.
To change the serial port function of serial port A, B, or E on the ICONM-BO-V breakout module, highlight the name of the breakout module’s serial port you want to configure, and then select a function fom the Option drop-down list box.
To change the serial port function on a port on the external interface device, highlight the name of the external interface port, and then select a option from the drop-down list box. You must restart IconMaster if you change Serial port baud rate, bits, parity, or stop bits.
Note
To ensure proper functionality, you should verify the IconMaster hardware configuration for RS-422 or RS-232 for use of internal serial ports.
RS-232 pinouts are different between Port A and Ports B and E.
See “Installing Breakout Modules” on page 43 for wiring details.
Multiviewer Configuration Settings
To use a multiviewer with IconMaster, a valid license is required. See “License
Management Settings” on page 195
for more information.
IconMaster supports the following multiviewers:
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
197
Chapter 9: Configuring IconMaster
• Harris CENTRIO
• Predator
198
Figure 9-37. Multiviewer Configuration Settings Dialog Box
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 9: Configuring IconMaster
For each multiviewer display the IconMaster will be controlling, create a profile which defines the multiviewer system, display output, and (optionally) the layout to display. Within the layout, you can define the PIP and UMD numbers that correspond to the IconMaster inputs (sources) and also the IconMaster outputs.
Table 9-8. Multiviewer Profiles Table in Multiviewers Configuration
Item Description
Enabled
Device Type
Always Active
Activates playout from IconMaster to this multiviewer
Select one of the following:
• Harris CENTRIO
• Harris Predator II
• Other
If selected, this profile will become the activeprofile, if no other profile is currently controlling the selected multiviewer display endpoint (multiviewer IP addresss and display number)
Profile Name File name of the profile to be called
Connection Type Options are based on the device type selection, and can include
Ethernet and serial
UMD Refresh
Interval
Delete
Determines the rate at which IconMaster will poll, measured in seconds
Clears the contents of the row, and contents of other associated tables (
)
For each row in the Multiviewers Profiles table, you can also configure other data, as displayed in
.
Table 9-9. Other Data Table in Multiviewers Configuration
Item
Connection
Destination
Port
Display
Layout Name
Description
For CENTRIO, the IP address of the Ethernet connector on the hardware device
The comm port the multiviewer connects through (leave blank if the multiviewer does not use a port)
The display number (ID) to control (value between 1 and 4) corresponding to the physical multiviewer Display output DVI
1/2 or HD_SDI 1–4)
The name of the layout to be loaded (If the layout name is blank, the multiviewer will not be commanded to change layouts, thus leaving the existing layout on-screen; PIPs and UMDs will still be refreshed)
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
199
Chapter 9: Configuring IconMaster
For each row in the Multiviewers Profile table, you can also configure PIP and
UMD data, as displayed in Table 9-10
.
Table 9-10. PIP & UMD Table in Multiviewers Configuration
Item
Input
PIP
UMD
Description
These items are defined in your multiviewer profile.
For each of PGM, PST, Clean, and every input source, enter the
PiP associated with the text label that will be the recipient of the UMD data.
For each of PGM, PST, Clean, and every input source, enter the
UMD address for that item.
These settings activate under monitor text labels and tally lights using a serial tally protocol. As a result, UMD text labels and serial tally indicators will be enabled on a multiviewer output device such as SuiteView.
Normally this will indicate, for example, the PIP on a video wall that is currently on the PGM monitor, PST Monitor, and/or Clean monitor.
IconMaster supports TSL protocol.
Clock and Timer
For the clock and timer to be available, a button needs to be defined for each.
See
“Button Configuration Settings” on page 204 .
200
Figure 9-38. Clock and Timer Settings Dialog Box
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 9: Configuring IconMaster
The Clock and Timer dialog box includes settings for IconMaster's real-time
clock and segment timer functions, each of which is detailed in Table 9-11
.
Table 9-11. Clock and Timer Settings Options
Item Description
CLOCK Enable Enables IconMaster to synchronize its internal real-time clock with an external clock source.
IconMaster uses the SNTP protocol across Ethernet to query an NTP time server.
CLOCK Source Enter the IP address of an NTP time server, as well as a time zone offset. NTP time server provides
UTC time, and requires the client (IconMaster) to provide a local time offset. By default,
IconMaster will re-sync its clock every 60 minutes. This can be changed by editing the Re-Sync
Interval field.
If using IconMaster's RCP as the clock source, the RCP must be connected to an external LTC timecode time-of-day source. Enter the RCP's IP address as the SNTP Server IP Address. In this status, the local time offset (Time Zone) setting will be ignored by IconMaster.
NOTE:
• IconMaster does not maintain its real-time clock when power cycled. The NTP server (or RCP) must always be available when IconMaster powers up and during operations.
• Press the CLOCK button on IconMaster's RCP to Re-Sync IconMaster's clock with the NTP server.
• The "Start" time of DST should be local time and the "End" time of DST should be local time with DST shift.
Daylight Savings
Time
IconMaster can automatically adjust for daylight savings time, if configured. If configuring a custom DST adjustment window, IconMaster will add one hour between the start and end times defined.
NOTE: if configuring a custom DST window, the dates may need to be changed annually.
If using IconMaster's RCP as the clock source, settings will be ignored by IconMaster, so just select
Disable DST.
CLOCK Display IconMaster can display the clock in either 12h or 24h formats. When configured for 12h format,
IconMaster can display AM/PM indicators. The Frame Count can also be optionally displayed.
TIMER Enable Enables IconMaster's segment timer functionality. When enabled, IconMaster will reset the segment timer to zero on each transition of the BKGD source.
Reset Timer There are two options: FX and Keyer/AO. Check one or both of these options, and IconMaster will reset the segment timer on each FX transition and/or all keyer (video and Audio Over) transition.
Clock and Timer are managed by the MKE card(s). They are not local to an
RCP but they can change depending on what MKE the RCP is connected to. If the LTC output of a RCP is set to track the timer, it will NOT reset at a segment end if the panel is not connected.
The clock display of an RCP connected to a MKE that has never synced up with an NTP server will be --:--:--.--.
The text on the clock will be inversed if an RCP connected to a MKE has failed to resync with NTP server. In this situation, the MKE is free running (relying on its own clock).
The LTC output is only available on the HRCP RoHS compliant version of the
HRCP ( 855T RCP). The LTC output on the RCP is frame drop in 29.9, no frame drop in 25.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
201
Chapter 9: Configuring IconMaster
Panels Group Settings
The Panel configuration menu group appears when you have selected “Control
Panel Configuration” as your type of configuration.
Figure 9-39. Panel Menu Group
This menu group controls the panel-specific configuration and panel network
configuration functions, as shown in Figure 9-39 . The functions controlled by
this item group are described in .
Note
When uploading a new panel configuration, the control panel will disconnect from any IconMaster channel currently under control, and will automatically connect to Channel 1. Similarly, all Primary and Secondary channel groups will be disconnected, and must be re-established.
202 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Panel Network Configuration Settings
Chapter 9: Configuring IconMaster
Figure 9-40. Panel Network Configuration Dialog Box
The Panel Network Configuration dialog box contains the network address settings that are necessary for the IconMaster control panels to communicate with the IconMaster MKE-3901 modules.
To change or set the name of the IconMaster control panel (up to 8 characters in length), click in the Control Panel Host Name field, and then type the new name. The factory default for the IconMaster control panel is 192.168.100.251, and will be shown in the Control Panel IP Address field.
• To change the IP address of the IconMaster control panel, select the New IP
Address check box, and then enter the new IconMaster Control Panel IP
Address.
• To change the Subnet Mask, enter the new IP address in the Subnet field.
• To change the Gateway IP address, enter the new IP address in the Gateway field.
The Master Assignment section of the dialog box allows you to enter the names and IP addresses of up to 8 MKE-3901 modules that the IconMaster control panel can communicate with. To change or set the name of an
IconMaster MKE-3901 module, click in the Host Name field, and then type the new name, up to a maximum of 8 characters.
Similarly, to change or set the address of the IconMaster MKE-3901 module, click in the IP Address field, and then type in the new IP address.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
203
Chapter 9: Configuring IconMaster
If you have configured the IconMasters to interface with multiviewers, you can assign up to three profiles to be automatically recalled and controlled when the
RCP connects to the IconMaster. These profiles are setup and named for each
IconMaster individually. See page 197 to configure the profiles.
When the RCP connects to the given IconMaster, it will recall the profile defined in the Multiviewer Profile 1 Name field. Optionally, the operator may choose to recall profiles 2 and 3 at connect time, and may change to these display profiles anytime during operations. If a Profile Name field is blank, no profile operations will be initiated by connecting an RCP to the IconMaster. If no multiviewer profiles are configured on the RCP, but “Always Active” profiles are enabled on the IconMaster MKE-3901 module, the MKE-3901 will continue to maintain an active connection to the “Always Active” multiviewers, providing PiP, UMD, and layout updates as necessary.
Button Configuration Settings
Configurable cluster
Configurable cluster
Transition cluster
Figure 9-41. Button Configuration Dialog Box
Using the Button Configuration dialog box, you can assign specific functions to the configurable clusters and to the transition cluster on the IconMaster main control panel. The available functions for each group of buttons are shown in
204 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 9: Configuring IconMaster
WARNING
Always ensure that channel buttons are allocated left to right, with Channel 1 on the left most button of Cluster 1.
Table 9-12. Button Clusters, Functions, and Selections
Button Group Function
Cluster 1 and Cluster 2 Frame Select
Transition Cluster
GPO Output control
Quick Selects
Fast Reset
(cluster 2)
Clocks & Timers
Fade to Silence
Fade to Black
Transition Rates
Breakaway
Automation Hold
Effects
Fade Types
Machine Control
None
Selections
CH 1, CH 2, CH 3, CH 4, CH 5,
CH 6, CH 7
GPO1, GPO2, GPO3, GPO4,
GPO5, GPO6, GPO7, GPO8,
GPO9, GPO10, GPO11, GPO12,
GPO13
QS 1, QS 2, QS 3, QS 4, QS 5, QS
6, QS 7, QS 8
SET, CLEAR, RECALL (appear in
Parameter Adjustment Control cluster)
TIMER, CLOCK
SIL
FTB
SLOW, MED, FAST, CUT
AUDIO, VIDEO
HOLD
FX
TAKEFADE, FADETAKE,
FADEFADE, CROSSFADE
CUE, FF, MARK, PLAY, REW,
STOP
None
Note
Changing any of the Transition Cluster functions will require the replacement of the text film on the corresponding IconMaster control panel button. See the IconMaster Operation and
Configuration Manual for more information.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
205
Chapter 9: Configuring IconMaster
To assign a function to a button, click the graphical button in the dialog box.
A pop up window will display a graphical image of the current function assigned to the button, as well as a drop-down menu. The drop-down menu will list the available functions that can be assigned to the selected button. Select the new function from the drop down menu then click OK to accept the change, or
Cancel to exit.
The newly assigned function name will appear on the graphical button. Each function can only be assigned to 1 button at a time. If the drop-down menu does not list the function you want to assign, either the function is not available for that button, or the function is already assigned to another button.
Note
Frame Select buttons must be assigned starting with the far left button on Cluster 1.
LTC Configuration
Figure 9-42. LTC Configuration Dialog Box
To configure your LTC output, choose the source you want the output to follow, which can be either Timer or Clock.
206 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 9: Configuring IconMaster
Quick Configuration Quick Reference Chart
This section provides a quick reference chart for the main control panel functions. It shows the control panel clusters (as illustrated in
Figure 9-43 on page 207 ), the functions that fall within each cluster, and the ICU dialog box
that allows you to configure that particular function.
Configurable cluster 1
Parameter adjustment control cluster Configurable cluster 2
AUX (Auxiliary) bus
PGM (Program) bus
LCD character input source display
PST (Preset) bus
Configurable Transition functions
Figure 9-43. Primary Busses on the Main Control Panel
Transition controls
Table 9-13. Busses, Functions, and Configuration Utilities Relationships
Control Panel Item
Configurable cluster 1 and 2
Functions
Fade to Black (FTB)
Fade to Silence (SIL)
CLOCK, TIMER
Quick Select (QS1•••QS8)
GPO output control (GPO1•••GPO13)
Frame select (CH1•••CH8)
Setup Information
Button Configuration (
)
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
207
Chapter 9: Configuring IconMaster
Table 9-13. Busses, Functions, and Configuration Utilities Relationships (Continued)
Control Panel Item
Configurable cluster 2
Parameter adjustment control cluster
Aux bus
Program bus)
PST (Preset) bus
Functions
Fast Reset
Source Select (SRCSEL)
Keyer control (KEYER)
Transition control (TRANS)
Audio control (AUDIO)
Effects control (FX)
Quick Selects (Q-SEL)
Preconfigured auxiliary bus preview
(AUX)
PGM
PST
Setup Information
System Configuration ( page 190 )
)
Keyer (
)
Transition (
)
Audio Configuration (
)
Effects (
)
Primary Inputs (
)
System Configuration ( page 189 )
Primary Inputs (
)
System Configuration ( page 189 )
Button Configuration (
)
Transition (
)
Button Configuration (
)
Configurable transition functions Hold
Transition Rate
Slow
Medium
Fast
Cut
Breakaway
Audio
Video
Transition Effects
FX
Transition Type
Take-fade
Fade-take
Fade-fade
Cross-fade
Machine Control Type
Cue
FF
Mark
Play
Rewind
Stop
Button Configuration (
)
Effects (
)
Button Configuration (
)
Transition (
)
Button Configuration (
)
Machine control (
)
Button Configuration (
)
208 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 9: Configuring IconMaster
Table 9-13. Busses, Functions, and Configuration Utilities Relationships (Continued)
Control Panel Item
Transition control cluster
Functions
External keys
Key 1•••Key 2
Internal keys
Key 3•••Key 6
Audio Over
Audio-over 1•••Audio-over 2
Background (BKGD)
Transition “hot” button
Preroll
Take
Fader bar
Setup Information
Keyer (
)
Keyer (
)
Audio Configuration (
)
—
System Configuration ( page 189 )
—
—
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
209
Chapter 9: Configuring IconMaster
210 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 10
Enabling a Router Database for Use with an
IconMaster System
Overview
The IconMaster makes use of the Harris router configuration tools to create a router database for use in the IconMaster’s setup and for select operations.
• If you are connecting the IconMaster to a Harris router for which you already have a Router database, you can use this database as a starting point.
Otherwise, use CCS Navigator to create a router database consisting of all sources and destinations which will be used with your IconMaster system.
• Once a router database has been created, you will use the Harris Navigator software to send this database to the IconMaster. You can also edit the database at any time from within Navigator, and update the IconMaster with a simple button press.
• To configure the IconMaster’s source inputs from the router, you will use the IconMaster Configuration Utility (ICU) to assign router sources as
IconMaster inputs.
• Finally, if you have configured IconMaster inputs as Dynamic, you will use this database to assign new router sources to the IconMaster inputs.
This chapter provides you with the information you need to perform these procedures.
The discussion that follows is based on the assumption that you have a working knowledge of Routers and the Navigator software application, and have used their other capabilities. If not, please refer to the appropriate manuals to familiarize yourself with their functions.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
211
Chapter 10: Enabling a Router Database for Use with an IconMaster System
Setting Up a Router Database
Note
Databases for several popular Harris router configurations have been provided with your IconMaster system. These can be found in the IconTools software directory (typically C:\Program Files
→
Harris
→ IconTools). You can use these databases, or create
your own. See page 142 for a list of these “getting started”
database files.
The steps described below direct you through the process to use for adding a router to a router database. For illustration purposes, the discussion will focus on adding a Panacea 16×4 routing switcher via Polling. For specific information on adding or editing other Harris routers, please see your CCS Navigator documentation.
If you have set up a router database for your IconMaster primary router already, you do not need to set it up again. Go directly to the section titled
IconMaster Configuration” on page 217 .
1. Launch the Navigator application (Start
→ Programs → Harris
Navigator).
212 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 10: Enabling a Router Database for Use with an IconMaster System
2. In Build mode, select Router
→ Create → Routing System from the
Navigation pane.
Figure 10-1. Create Routing System Sequence of Steps
A dialog box opens.
Figure 10-2. Create Routing System Dialog Box
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
213
Chapter 10: Enabling a Router Database for Use with an IconMaster System
3. Enter a name for the router system, and then check Start from a blank
configuration.
4. Click on Perform System Poll and enter the communication protocol and
IP address for the Panacea router, and then click OK.
5. In Navigator’s Navigation pane, browse to Routers > <name> > Routers and double-click on the Panacea 0 item.
6. Select the Router Frame tab. Panacea module information such as matrix size, type, and module options will be displayed (see
). These will vary, depending on your Panacea’s matrix type.
214
Figure 10-3. Router Frame Tab
7. Select the Detected Cards tab.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 10: Enabling a Router Database for Use with an IconMaster System
Panacea module information such as card type, back panel type, and firmware version will be displayed.
Figure 10-4. Detected Cards Tab
8. Select the Detected Matrices tab.
Matrix information should resemble the information shown in
.
Figure 10-5. Detected Matrices Tab
9. Click OK to close the dialog box.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
215
Chapter 10: Enabling a Router Database for Use with an IconMaster System
When the database is first created, each logical source will be assigned a generic name such as “Input 1,” “Input 2,” etc. Each logical source can be renamed to uniquely identify the source. A source name can contain any 8 characters. To rename a source: a.
In the Navigation pane, select Routers > <name> > Control Views and double-click on the <Name> item.
The Edit Logical Database window will appear. b. Select the Sources tab.
c.
Highlight the text in the Name box.
216
Figure 10-6. Edit Logical Database d. Over-type it with the new name. e.
Make sure that you follow the category/indexing format as described below.
When a source name is entered in the database, the name automatically creates a category. All characters to the left of last space in the source name become the category (the space will be included in the category name). All characters to the right of the space will become the index. If the source name does NOT include a space, the entire name will be used to create the category name. This may limit the number of sources that can be accessed from the panel. Use spaces appropriately when naming sources. If any character after the space is not a valid index character
(valid characters are any combination of numbers, 0-9), the entire name will be used to create the category name.
• If a logical source is named “VTR 1,” the category is named
“VTR.”
• If “VTR1” is typed without a space, the category “VTR1” will be created.
• If “VTR 10Z” is typed, a category named “VTR 10Z” will be created (not a category “VTR” and an index “10Z”).
10. If you made changes on any of the router tabs, the message “Needs
Download” will appear next to the router name listed on the Navigation pane. Highlight the router and click Download to download the revised settings to the router.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 10: Enabling a Router Database for Use with an IconMaster System
Defining the IconMaster Configuration
1. At the View for Administrators list, locate the Catalog selection. If necessary, expand the selection to view the sub-entries.
2. Under the IconMaster sub-entry, locate the IconMaster (MKE) entry. Drag the entry up to the Configuration selection, and then drop it into the
Configuration selection.
3. Click Yes to confirm the operation.
Drag this item to the
Configuration Router view folder.
Drop item from Catalog folder here.
Drop item from Router folder here.
Drag this item to the
Configuration folder.
Figure 10-7. Drag-and-Drop IconMaster (MKE) Entry
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
217
Chapter 10: Enabling a Router Database for Use with an IconMaster System
The following dialog box appears:
Figure 10-8. IconMaster (MKE) IP Dialog Box
4. Enter the IP address of the MKE-3901 module, and then click OK.
5. If necessary, expand the Configuration selection to view the sub-entries.
You will now see an entry for IconMaster (MKE), with a Router View sub-entry below it.
6. Drag the database entry under the Control View you created in step 6 on page 224 down to the Configuration selection, and then drop it into the
IconMaster’s Router View sub-entry.
7. Click Yes to confirm the operation.
218 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 10: Enabling a Router Database for Use with an IconMaster System
The MKE Configuration dialog box appears.
Figure 10-9. MKE Configuration Wizard Screen 1 of 3
8. On the first screen of the configuration wizard, enter a name for the configuration, and then click Next.
You cannot make any other changes on this screen.
9. On the second screen of the configuration wizard, you can select the sources that you want tto control. All of the sources that are established by the
Router System Control View are listed under Available sources. From this list, select the sources you want to add, and then click the > button (or, if you want to add all of the sources listed, click the >> button).
If you want to remove a source, select the one you want to remove, and then click the < button, or click the << button to remove all sources.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
219
Chapter 10: Enabling a Router Database for Use with an IconMaster System
You can filter the Available sources list by entering a keyword in the Filter box.
220
Figure 10-10. MKE Configuration Wizard Screen 2 of 3
Selected sources now lists the sources that you can control.
To determine the order in which the sources appear, use the following buttons:
• Up—Moves the selected items up one position in the list
• Down—Moves the selected items down one position in the list
• Top—Moves the selected items to the top of the list
• Bottom—Moves the selected items to the bottom of the list
• A–Z—Organizes all items in the list by alphanumeric order
• Z–A—Organizes all items in the list by reverse alphanumeric order
When you have completed organizing your Selected sources list, click
Next.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 10: Enabling a Router Database for Use with an IconMaster System
10. On the third screen of the configuration wizard, select the destinations that you want to control, using the same tools and methods you used to add and remove sources.
Figure 10-11. MKE Configuration Wizard Screen 3 of 3
11. Click Finish.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
221
Chapter 10: Enabling a Router Database for Use with an IconMaster System
12. Back in the Navigation pane, click the IconMaster (MKE) device in the
Configuration folder.
Click this device to transfer the configuration.
This is the configuration you just created.
Figure 10-12. Navigation Pane with IconMaster Configuration
The Configuration dialog box opens.
222
Figure 10-13. Transferring a Configuration to the MKE-3901 Module
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 10: Enabling a Router Database for Use with an IconMaster System
13. Highlight the device configuration you want to transfer, and then click
Perform Transfer to send the router database to the IconMaster.
14. Click Yes to confirm the transfer.
15. After the transfer is complete, click Refresh Device, and then click List
Configuration.
The XML files will be listed on the right side under List of All
Configurations on the Device. Confirm that the config.xml and routerdb.xml files are listed.
16. Click IconMaster Configuration Utility.
ICU starts and loads the frame configuration for the selected device.
17. In ICU, click Router Configuration.
18. Choose either Serial port or Ethernet depending on your routing system, and enter the IP address if required.
(For Platinum routers only) Under External Router, select Ethernet, and then enter the IP address for the PT-RES module. The Acquire Router
Database dialog box should open, with Download Database from
IconMaster selected. (If this dialog box does not appear, check Using
Routing Database.)
19. Click OK.
The routing database is now fully transferred to the IconMaster hardware.
To confirm that it is mapped correctly, check that the router levels match the database configurations on the Primary Inputs dialog box in ICU.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
223
Chapter 10: Enabling a Router Database for Use with an IconMaster System
Preparing the IconMaster Configuration
1. Launch the IconMaster Configuration Utility (ICU) by selecting the button labeled Launch IconMaster Config Utility or from the Start menu
(Start
→ Programs → Harris → IconTools → IconMaster →
IconMaster Configuration Utility).
2. If you have already created an IconMaster configuration, select File
→
Open, and then select your configuration file. Otherwise, select File
→
New, and then select the type of configuration to create (in this case, select
IconMaster Frame (Channel) Configuration.)
Figure 10-14. New Configuration Window
3. Click OK.
The main ICU window appears.
4. Under the System Config category on the left side of the ICU window, select Genlock and Standard.
From the Operation Standard drop-down list box select the operating standard you want to use.
224
Figure 10-15. Selecting Operation Standard
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 10: Enabling a Router Database for Use with an IconMaster System
5. Under the System Config category on the left side of the ICU window, select Network. Here you will identify the IconMaster’s MKE-3901 module’s Ethernet settings.
• Enter a new name into the IconMaster Channel Name text box.
• Enter the IP address, subnet mask, and (optionally) the network gateway settings for the IconMaster’s MKE-3901 module. When all entries are complete, close the Network window.
Figure 10-16. IconMaster MKE-3901 Network Settings
A few moments after entering the IconMaster IP address on the network page, the flashing OFFLINE will change to ONLINE, to indicate that the
IconMaster Configuration Utility has successfully detected and connected with the IconMaster MKE-3901 module.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
225
Chapter 10: Enabling a Router Database for Use with an IconMaster System
6. Under the System Config category on the left side of the ICU window, select Router Configuration. The Router Configuration window appears.
Make the following selections:
Figure 10-17. Selecting Router Mode and Router Database
Characteristics a.
Under Router Mode, click the External Router radio button. b. Under Router Database, click the Using Router Database and Sorted check boxes.
The Acquire Router Database window appears.
226
Figure 10-18. Acquire Router Database Window c.
Select the database source, and then click OK.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 10: Enabling a Router Database for Use with an IconMaster System d. Click Yes to confirm that you want to download the XML file.
Figure 10-19. Download Confirmation Window e.
Once the download is completed, click OK to close the Routing
Database Successfully Downloaded message.
f.
Click OK in the You must save your configuration file before
proceeding window to save the database.
Enter a location and file name for your configuration file in the Save As window.
If you are using a Platinum router, select “5” from the Router
Transition Delay box for a 5-frame router transition delay. If not, use the default setting of “1”.
At the bottom left of the ICU window, you will see displayed the frame name, the operating standard, and the IP address you just entered. You will also see the word Connecting.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
227
Chapter 10: Enabling a Router Database for Use with an IconMaster System
Assigning Router Inputs
1. Under the Input/Output category on the left side of the ICU window, click
Primary Input.
The Primary Input window will appear.
Figure 10-20. Primary Input Window
228 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 10: Enabling a Router Database for Use with an IconMaster System
Under Router Source Number, the level numbers displayed should match the levels set in your database. In the unlikely event that they do not, you can change the level number in the drop-down list boxes to match the levels set for your router. Set any unused level to Unused. Note that the Video column must have a router level assigned.
Figure 10-21. Changing Router Levels
2. For sources that will be dynamic, click the check box (es) next to the appropriate source(s).
3. Select the desired router source(s), and then select name of the router source from the Name drop-down list box.
Figure 10-22. Changing Router Source Names
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
229
Chapter 10: Enabling a Router Database for Use with an IconMaster System
4. For the Input Buses: Bus A and B, select the Name from the drop-down list box of the router destinations which are connected to the IconMaster’s A and B inputs.
Figure 10-23. Selecting Bus A and Bus B Inputs
5. Under the Input/Output category on the left side of the ICU window, click
Aux Bus. The Aux Bus window will appear.
230
Figure 10-24. Setting up Router Database Aux Operations
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 10: Enabling a Router Database for Use with an IconMaster System
Note
When ICU is configured for Router Database mode, the Aux bus presentation changes to allow selections from the router database for configuration of database sources.
If a database source is missing for a particular level/crosspoint, click on the desired cell within the Aux bus page, and then click
Manual. You can then override or assign a desired crosspoint data value.
6. From the Aux Bus menu in the top left of the dialog box, choose each bus, and then check or uncheck Enable.
Disabled Aux buses will not appear in the RCP, and will appear grayed out on the ISCP.
7. For enabled buses, type router sources, where they differ from those displayed on the screen.
8. Select File
→ Save As, and then enter a name for the configuration.
9. To send the configuration to the IconMaster, click the Send CFG to Frame button.
Figure 10-25. Sending Configurations to a Frame
At this point, you should have an operational IconMaster, which has inputs assigned from the router.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
231
Chapter 10: Enabling a Router Database for Use with an IconMaster System
Changing or Editing the Router Database
If you need to add, delete or change an entry for the IconMaster’s router, you will want to update the router database. This procedure describes the workflow to perform this change and update.
1. From within the Navigator application, select the IconMaster router database entry under the Routers
→ Control Views tree.
232
Figure 10-26. Router Database Entry Location
2. Double-click the IconMaster’s router database entry to open the database editor.
You can edit, add, delete, or change entries as needed. If you adjust the logical system size of your router configuration to be specific to
IconMaster, all source names, destination names, and router sources will have to be re-entered into the new database.
3. To update the database on your IconMaster, double-click the IconMaster
(MKE) sub-entry under the Configuration selection.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 10: Enabling a Router Database for Use with an IconMaster System
The Configuration for IconMaster (MKE) window appears.
Figure 10-27. Configuration for IconMaster (MKE) Window
4. Highlight the device configuration you want to transfer, and then click
Perform Transfer to send the router database to the IconMaster.
5. Click Yes to confirm the transfer.
6. After the transfer is complete, click Refresh Device.
Any router database changes you made will become active on the IconMaster within a few seconds. If you wish to change the assignment of router sources to
IconMaster inputs, use the IconMaster Configuration Utility to make these changes.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
233
Chapter 10: Enabling a Router Database for Use with an IconMaster System
234 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 11
Troubleshooting
IconMaster Troubleshooting Checklist
This checklist should be used to ensure that the basic system is configured and wired properly. It is important to follow though these in order; the logic here is important to diagnose configuration issues.
Breakout Module
Ensure the correct cable(s) are used for connecting to the IconMaster. The audio cables and the video cable look very similar. If the wrong cable is used, the
MKE-3901 module may not even power up properly. MKE breakout cable is part # 165-000242-00 the MKA breakout is part # 165-000242-00.
Communication
1. Verify correct IP addressing on MKE-3901, MGI-3903, RCP, and PC.
2. Verify all components connected to a 10/100baseT switch.
3. Check that the control panel has been configured to control the MKE-3901
IP address.
4. Ethernet port 1 on the control panel is not used. Port 2 must be connected.
Video Signals
1. Verify correct firmware version is loaded into both the MKE-3901 and
MGI-3903 modules. The version can be viewed from the card edge controls of each module. The letters SD or HD will be at the end of the version tag.
Both versions of firmware are available from our Web site.
2. Verify the correct genlock type and operating standard is selected in the
Genlock configuration of the IconMaster Configuration Utility (ICU). Once set, the file must be saved and uploaded to the frame. If the operating standard does not match with the firmware version in the module you will receive an error. Starting with v1.2 the software prompts you to load the firmware.
3. Verify genlock is present at the MKE-3901 module. There is a lock LED on the far left of the board that indicates valid signal presence.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
235
Chapter 11: Troubleshooting
4. Connect two video sources to the bus A and bus B inputs of the MKE-3901.
By selecting different sources on the program bus you should see the program output toggle between the two sources.
Video Output is not Valid
• Bypass the IconMaster and ensure the input source feeding the BusA and
BusB signals appear on your downstream monitor by connecting a BNC
"barrel" of the cable feeding IconMaster BusA/B input and the PST or PGM output monitor.
• Verify the signals feeding into IconMaster are of the correct video standard, as set up in the ICU configuration.
Internal Router Control (NEO NSM)
1. Verify correct settings on the NSM modules.
• The “first” NSM, which is used for inputs 1-5, should be set to Level 0,
SrcOffset 1, DestOffset 0.
• The “second” NSM, which is used for inputs 6-12, should be set to XY
Level 1, SrcOffset 1, DestOffset 0.
2. Verify that external router control is not selected in the System Config section of the ICU. Some versions may have a check box to select internal routing, otherwise deselect external. Any changes need to be uploaded to the frame.
3. Verify that LockStat 1 and LockStat 2 parameters on the NSM module are set to Free.
External Router Control (Panacea, Platinum, EDGE)
1. Verify jumpers on MKE-3901 module are set for RS-232 or RS-422 control.
2. Verify jumper pack on breakout module is set for RS-232 or RS-422.
3. Verify cable pinout is correct for RS-232 or RS-422 connection to the router.
4. Verify the router serial port is correctly set for RS-232 or RS-422.
5. Verify that the router serial port is set to 38400 baud.
6. Verify that the serial cable to the router is connected to port E on the breakout module.
7. Verify that the level, source, and destination setup in the System
Config/External Router Configuration of the ICU and wiring match.
Audio Overs
When using the breakout module the audio over jumpers on the MKE-3901 module must be set to balanced, even if unbalanced AES inputs are used.
236 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 11: Troubleshooting
Software/Firmware
Verify the firmware versions of all IconMaster components: MKE-3901,
MGI-390x, RCP, ICU. All software and firmware components must be from the same release. If one component is upgraded, the entire system must be upgraded.
Cannot PING the IconMaster Components From a Computer
• Check IP addresses of Harris IconMaster component and that computer
• Check network mask settings
• Check computer for filewalls or blocked ports
• Ensure you can PING any other network devices from that computer
• Check the lights on the Ethernet router(s) to ensure all devices are connected and operational
RCP Cannot Connect To An IconMaster Channel (MKE)
If the RCP's channel button is RED, then the RCP has a valid Ethernet connection to the MKE channel, and is receiving regular heartbeat (keepalive) messages.
If you press a GREEN channel button, and it does not turn (and remain) RED, there are network connectivity problems preventing the RCP and the MKE to connect. Check IP addresses, router connections, and equipment configuration settings.
Cannot Communicate to the Primary Router
If IconMaster cannot communicate to the primary router, the primary source buttons will FLASH, indicating a router communications error.
Note
Some systems may indicate a router communications error (by flashing) only at powerup. Pressing any PST source button will clear this indication. This is normal, and does not indicate an error.
• Ensure the BKGD button on the RCP panel is selected and illuminated. If not selected, IconMaster will not change the background source on the PST bus. THIS IS THE MOST COMMON MISUNDERSTANDING.
• If set up for serial router communications:
• Verify the correct serial port is set up (ICU, System Config > Router
Configuration)
•
Verify RS232 -vs- RS422 settings (jumper on MKE -3901 (see “Changing
MKE-3901 Front Module Jumpers Setting” on page 31 ) and jumper pack
on breakout module (see
“DB-9 Connectors” on page 48 )
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
237
Chapter 11: Troubleshooting
• Verify correct serial port wiring is used (see
“DB-9 Connectors” on page 48 )
If using an SPT to connect to the router, verify the DIP switch settings on the
SPT for baud rate, protocol select, and XY terminations. An internal jumper pack must also be set correctly for either RS-232 or RS-422.
If set up for Ethernet connection, verify the correct router IP address information (ICU, System Config ' Router Configuration)
Using ICU, verify the router setup on the System Config > Router
Configuration and the Input/Output > Primary Input screen.
Verify the correct router level and destinations are set up (ICU, Input/Output '
Primary Input).
Monitor the router BusA and BusB destinations using a router control panel.
Try selecting different sources to these router outputs: do these changes propogate through to the IconMaster outputs?
Cannot Control the Internal (Logo) Keyers
Internal logo keyers are only available for IconMaster systems with MGI-390x modules. IconMaster LITE systems do not include this module, and will not support internal logo keyer operations.
• If the Internal Keyer buttons are dark and do not display any text, the
IconMaster is configured as a LITE system and is not authorized to support internal logo generators/keyers. If this is in error, contact Harris Customer
Support to review the IconMaster LITE license and to verify your
MGI-390x module is included.
IconMaster licenses are applied through the ICU's License Management menu:
238
Figure 11-1. Adding a License
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 11: Troubleshooting
• Select Get License to retrieve and display the IconMaster's MKE-3901 module serial number, and provide this information to the Harris Customer
Support team.
If the Internal Keyer buttons display the message "NO MGI CARD FOUND", the MKE module has not detected the MGI module. Remove the IconMaster card set from the NEO frame, and check the module-to-module connections.
Ensure the board-to-board screws are securely fastened.
If the Internal Keyer buttons display the message "PLEASE WAIT LOADING
LOGOS", the MGI module is still in the process of loading logos from its offline (Compact Flash) storage, to online DDR memory. This process may take some time, depending upon the number of logos, logo size and duration, etc.
The color of the Internal Keyer's tally LCD is also helpful in troubleshooting:
• OFF = No MGI card discovered, or IconMaster LITE
• GREEN = Logo keyer is available, and not on-air
• RED = Logo keyer is on-air
Cannot Control the External Keyers
The color of the External Keyer's tally LCD is also helpful in troubleshooting, and indicates whether an external fill/key signal is present to the IconMaster, and if the signal is timed or non-sync with the PGM signal.
• OFF = External fill/key signal is not present.
IF the keyer is configured for self-key, only the FILL signal is checked.
IF the keyer is configured for any other type of key, both the FILL and KEY signals must be present.
• GREEN = Keyer has a valid signal, and is not on-air.
• RED = Keyer is on-air
• ORANGE = Keyer has a signal, but the signal is either invalid, or not properly timed with the PGM signal and is considered non-sync. It will key into the program video, but may be vertically offset from the intended on-screen location.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
239
Chapter 11: Troubleshooting
Navigating the Service Menu
You can access the Service menu through the Parameter Adjustment Control cluster. Via the Service Menu, you can see the IconMaster software version in use, view or change the control panel IP address, or view the numeric value of a fader bar position. Press all four buttons simultaneously to access this menu.
Figure 11-2. Service Menu
Verifying the IconMaster Software Version
1. Access the Service Menu.
2. Turn the left scroll knob until the PNL S/W parameter appears. Reading from left to right, you will see a display of the current version of the control panel software. You cannot change this parameter.
3. Turn the left scroll knob until the PUSH EXIT parameter appears.
4. When finished, turn the PUSH EXIT display button to return to the main
Parameter Adjustment Control cluster menu.
Changing IP Address for the Control Panel
1. Access the Service Menu.
2. Turn the left scroll knob until the PNL IP ADDR parameter appears.
Reading from left to right, you will see a display of the control panel’s current IP address.
3. Select the button that contains the IP address component that you want to change, and then turn the right scroll knob to change the number on that button.
4. After you enter the last digit of the IP Address, press the right knob to save the new IP Address.
5. When finished, turn the left scroll knob until the PUSH EXIT parameter appears.
6. Press the PUSH EXIT display button to return to the main Parameter
Adjustment Control cluster menu.
240 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 11: Troubleshooting
Identifying Fader Bar Relative Positions
1. Access the Service Menu.
2. Turn the left scroll knob until the Fader Test parameter appears. The pushbutton on the extreme right will display a numeric value. This numeric value represents a straight linear value that denotes the relative position of the fader bar.
3. If necessary, move the fader bar up or down to the position you want. The numeric values in the right pushbutton will change to correspond with the fader bar’s relative position.
4. When finished, turn the left scroll knob until the PUSH EXIT parameter appears.
5. Press the PUSH EXIT display button to return to the main Parameter
Adjustment Control cluster menu.
Getting Help from Customer Service
We are committed to providing round-the-clock, 24-hour service to our customers around the world. Contact our website or the Customer Service team
Table 11-1. Customer Service
Phone: 1-416-642-3611
Toll Free: 1-888-LEITCH6 (534-8246)
Fax: 1-416-445-9020
E-mail: [email protected]
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
241
Chapter 11: Troubleshooting
242 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 12
Specifications
Overview
The following tables list specifications for the IconMaster system.
•
•
•
•
“GPI Inputs and Outputs” on page 249
•
“Power Consumption” on page 249
•
•
“Miscellaneous Items” on page 250
Specifications and designs are subject to change without notice.
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
243
Chapter 12: Specifications
Inputs
Serial Digital Video
Table 12-1. Serial Digital Video Specifications
Item
Number of inputs
Standard
SDTV
HDTV
Specification
7; A, B, Fill1, Key1, Fill2, Key2, squeeze background
Equalization
Connector type
Return loss
Impedance
270 Mb/s per SMPTE 259M 525i/59.94, 625i/50
1.485 Gb/s serial per SMPTE 292M 1080i/50,
1080i/59.94, 720p/50, 720p/59.94
Automatic up to 100m (328 ft.) of Belden 1694
BNC
>15 dB
75
Ω
Analog Video Reference
Table 12-2. Analog Video Reference Input Specifications
Item Specification
Connector type
Number of inputs
BNC
1 Genlock
Return loss -40 dB to 6 MHz
Impedance 75
Ω
Reference type NTSC/PAL, color black, or 525/625 comp sync or
Tri-Level per SMPTE 240M
29.97/30/60/25
Level
Connector type
200 mV to 2 V nominal
BNC
244 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 12: Specifications
Outputs
Digital Video
Table 12-3. Digital Video Outputs Specifications
Item
Standard
SDTV
HDTV
Specification
Connector type
Number of outputs
Return loss
Impedance
270 Mb/s per SMPTE 259M 525i/59.94, 625i/50
1.485 Gb/s serial per SMPTE 292M 1080i/50,
1080i/59.94, 720p/50, 720p/59.94
BNC
4; PGM (2), PST, CLEAN
>15 db
75
Ω
Keyers
Table 12-4. Keyer Output Specifications
Item
Number of keyers
Number of key processors
Key modes
Specification
6 (2 for IconMaster LITE)
2 external fill+key
4 internal (0 internal for IconMaster LITE)
Multiplicative; additive; self (Key 1, 2); matte (Key 1, 2)
System Video Delay
Table 12-5. System Video Delay Specifications
Item
FX module installed
No FX module installed
SDTV
HDTV
Specification
+1 frame
3.7
μs + (0 to 1) video line
1.5
μs + (0 to 1) video line
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
245
Chapter 12: Specifications
Audio
Embedded
Table 12-6. Embedded Audio Specifications
Item
Standard
SDTV
HDTV
Specification
Per SMPTE 272M (embedded as 20-bit audio only)
Per SMPTE 299M (embedded as 24-bit audio)
48 KHz per AES3-1992
Channels
SD
HD
Mode
HANC
SDTV
HDTV
2 or 4 groups (4 or 8 AES pair, 8 Ch. Discrete)
4 groups (8 AES pair, 8 Ch. Discrete)
Delete existing and rewrite new audio groups
Non-audio data will be repacked and rewritten
Non-audio data will not be repacked and rewritten
Discrete Audio for Audio Over
Table 12-7. Discrete Audio for Audio Over Specifications
Item
Input/Output
Resolution
Specification
2 AES
24-bit operation (20 bit operation set at the output by configuration)
Sampling rate
Input
Sample rate converter
SRC disable
Connector
Format
48 KHz (33, 44.1KHz)
No
Multi-pin DB62
AES audio levels
246 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 12: Specifications
Discrete AES Audio Bus A and B
Note
AES 3-1992 allows the LSB to be used for “Non-Program Audio.” If the LSBs are being used this way, the SRC must be turned off to allow for 20-bit operation. If the data is 20 bit, but the LSBs are all
“0,” no action needs to be taken.
The following specifications apply when the optional MKA-3901 audio module is used in conjunction with the IconMaster.
Table 12-8. Discrete AES Audio Bus A and B Specifications
Item
Input
Output
Resolution
Input
Specification
4 AES in each for bus A and B
4 AES for PGM, PST, Clean
20- or 24-bit operation, set by data configuration bits (with
SRC off)
24-bit operation Output
Sample rate converter
SRC disable
Sampling rate
Input
Output
Connector
Format
No
48 KHz (33, 44.1 KHz)
48 KHz
Multi-pin DB62
AES audio levels
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
247
Chapter 12: Specifications
Audio Processor
Table 12-9. Audio Processor Specifications
Item Specification
Number of bus inputs 2 - A, B
Number of AES streams 4
Channel assignment
Modifiers
Not restricted within A path or B path
• Left or right invert
• Left and right sum
• Independent left and right level
Number of audio overs 2
Transitions
Dolby-E handling
Audio delay
Dissolve, cut, fade-fade, cut-fade, fade-cut
• Restricting transition to “cut”
• Other actions TBC
• 160
μs without FX module installed
• +1 frame with FX module installed
AES User and Configuration Bits
Table 12-10. AES User and Configuration Bits Specifications
Item
C bits input
C bits output
U bits input
U bits output
Specification
Read and analyzed for Format, word size only
• Reinserted based on ICU settings
• Selectable individually for each AES path
• Implementation level is “standard”
Not read or used
• Reset to 0
• Common for all AES paths
Monitoring Audio Level
Table 12-11. Monitoring Audio Level Specifications
Item
Monitor gain control
Specification
0 to 100%
VANC Data
For 525 systems, line 21 may be selected to be part of active picture or blanking.
Set this parameter using the IconMaster configuration utility software.
Table 12-12. VANC Data Specifications
Item
VANC data
Specification
Data will be allowed to “pass through” video processor
248 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Chapter 12: Specifications
GPI Inputs and Outputs
It is assumed that these inputs/outputs are externally isolated. They are low voltage TTL style input/outputs.
Input
Table 12-13. GPI Input Specifications
Item
Quantity
Type
Polarity
Voltage range
Current load
Connector
Specification
18 (8 for IconMaster LITE)
Non isolated TTL
Software specified
-0.3 V to 5.3 V max
1 mA
Part of 62-pin “D”-type
Output
Table 12-14. GPI Output Specifications
Item Specification
Quantity
Type
Polarity
Voltage range
Load
Connector
13 (7 for IconMaster LITE)
Open drain
Software specified
-0.3 V to 5.3 V max
40 mA max
Part of 62-pin “D”-type
Power Consumption
Table 12-15. Power Consumption
Item
Control panel
Frame
Power Consumption
250 W maximum; 150 W typical
• NEO: <25 W
• Panacea: 70 W (1RU) or 105 W (2RU)
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
249
Chapter 12: Specifications
MGI-3903
Table 12-16. Ethernet Port Specifications
Item
Standard
Connector
Specification
10/100Base-T IEEE 802.3u
8-pin RJ-45
Miscellaneous Items
Table 12-17. Miscellaneous Specifications
Item Specification
Timecode IN Per ANSI / SMPTE 12M, XML Female supporting unity speed, forward counting LTC
Timecode OUT Per ANSI / SMPTE 12M, XLR Male
Ethernet 10/100BaseT IEEE 802.3u Via RJ-45, 8-pin
12-36 VDC, 4-20 mA via 44-pin, HD-type female connector Temperature probe
Temperature
Performance
Operating
41° – 104°F (5° – 40°C)
32° – 122°F (0° – 50°C)
250 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Index
Keywords
A
Adaptor replacement information
Adjusting system timing
AES input and output pinouts
AES input connectors
AES output connectors
AES user and configuration bits specifications
Alarm definitions
Alarms
All, Operator, and Tree View parameters
Analog video reference specifications
Audio and video NSM routers
audio configuration settings
audio over matrix settings
–
breakout module balanced
–
coaxial
processor specifications
specifications
transition types
Audio breakout module balanced
–
coaxial
Aux bus configuration settings
B
Background source box
Breakout modules
Buttons button configuration settings
customizing
groups
Bypass relay control and jumper
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
C
Changing background sources
channel positions
channel squeeze ratios
control panel IP address
crop sizes
Closed captioning
Communication protocols of IconLogo
Compact flash card
Computer minimum requirements
Configuration, non-network
Configuring
PC monitors
Connectors
Ethernet
,
main control panel components
MKA-3901
–
multifunction I/O
power supply
Control control panel
IP address
Control panel assembly
CPU BOOT. See DIP switch settings
Creating effects
L-bars
wipes
Customizing control panel pushbuttons
Cutout dimensions
D
Desk and tabletop mounting of control panels
Digital video specifications
Dimensions of cutouts
DIP switch settings
251
Index
Disabling effects
Discrete
AES audio specifications
audio specifications
Display properties
Duration column
E
Editing effects name
Effects changing background sources
channel positions
channel squeeze ratios
crop sizes
creating
before you begin
L-bars
wipes
disabling
editing names
enabling
resetting
selecting channels
settings
Embedded audio specifications
Emergency Alert System (EAS) connections
Enable Silence While FTB option
Enabling effects
Ethernet connectors
miscellaneous specifications
port specifications
Ethernet connections
F
Fade to black
Fade to silence
Fader bar
Failsafe bootloader. See DIP switch settings
Flash card
Follow Video option
Frame select
FTB
FTB Transition Rate
252
G
Genlock selecting source type
Genlock settings
Genlock source type
GPI settings
GPI output control
GPO settings
GPO option
H
Hardware requirements of PC
I
IconMaster Configuration Utility initializing software
–
installing software
managing databases
menu groups control menu
frame configuration
functional menu
input and output
panel configuration
panel menu
panel settings
system configuration
menus input and output groups
opening databases
removing software
saving databases
starting software
uploading databases
ICONM-BO-V. See Video breakout module
ICONM-BO-VAB. See Audio breakout module, balanced
ICONM-BO-VAC. See Audio breakout module, coaxial
Initializing ICU
–
Input connectors
Input specifications
Installation control panels
IconMaster Configuration Utility
MKA-3901 submodule
MKE-3901-FX submodule
NEO modules
routers
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
IP address
IconMaster control panel
MKE-3901
J
Jumpers
bypass relay
ICONM-BO-V video module
MKE-3901
K
Keyer specifications
Keyer settings
L
L-bars
LEDs
ACT and MTD
and module indicators
compact flash card active
M
Machine control disabling settings
selecting automation types
selecting settings
settings
Major alarms
Managing ICU databases
Master Assignment section
Menu groups button configuration
frame configuration control
functional configuration
system configuration
–
input and output
panel
panel configuration
MGI-3903 module
Minimum requirements of computer
Minimum system requirements
Minor alarms
Miscellaneous specifications
MKA-3901
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation pinouts
AES input connectors
AES output connectors
MKA-3901 submodule
MKE-3901
–
,
MKE-3901-FX submodule
Modes of operation
100% (traditional) mix
50% (complementary) mix
Module Status indicator
Monitoring audio level specifications
Mounting brackets
,
Multifunction I/O connector
–
N
navigating parameter lists
NEO module installation
–
Network settings
O
Opening Existing ICU databases
Operating standard
settings
Operation Standards menu
Operator, Tree View, and All List parameters
Output connectors
Output specifications
P
Panel network configuration settings
Parameter adjustment control cluster
Service menu
parameter lists
Tree View
Parameters
Setup
PC requirements
Pinouts
AES inputs and outputs
–
bypass relay
MKA-3901
–
MKE-3901
Power consumption specifications
Power indicator
Power requirements
Power supply connectors
Precautions, safety
Preroll
Index
253
Index enabling status
setting duration
Primary input settings
Product servicing
Protocols, communication
Pushbutton customizing
Q
Quick select
Quick Select settings
R
Rack mounting of control panel
–
Removing ICU
Resetting effects
Returning a product
Revision history of manual
Router configuration settings
Routers
NEO
Panacea
Platinum
–
RS-232 and RS-422 protocols
RS-232-D port
S
Safety precautions
Saving ICU databases
Segments field
Selecting effects channels
Serial digital video specifications
ports
Serial options
Service menu
Set All Durations Equal to Current Record’s
Duration
Settings audio configuration
audio over matrix
auxiliary bus configuration
button configuration
Effects
genlock
GPI
–
GPO
keyer
machine controls
254
network
operating standard
panel network configuration
primary inputs
Quick Select
router configuration
UMD
Setup parameters
Shipping information
SIL
,
Software version, verifying
AES user and configuration bits
analog video reference
audio
–
audio processor
Digital video
discrete AES audio
discrete audio
embedded audio
Ethernet port
input
keyer
miscellaneous
Ethernet
timecode
monitoring audio level
output
power consumption
Serial digital video
temperature
VANC data
Standard, operating settings
Starting ICU
Support documents
System configurations
NEO
–
Panacea
Platinum
System requirements
System timing adjustment
T
Table and desktop mounting of control panels
Temperature specifications
Transition control cluster fader bar
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
Transitions functions cluster
rates
types
Tree View parameter list
Tree View, Operator, and All List parameters
Type column
U
UMD settings
Unpacking information
Uploading ICU databases
–
V
VANC data specifications
Verifying software version
Vertical blanking interval. See Closed captioning
Video and audio NSM routers
breakout module
Video breakout module
–
W-Z
Wipes
Writing conventions
Index
IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
255
Index
256 IconMaster Installation and Configuration Manual
Copyright © 2005-2010, Harris Corporation
ดาวน์โหลด