ORTEC GammaVision-32 V5.2 Gamma spectroscopy, GEM 100% Ge Detector, CFG-PV-1 Vertical Cryostat, DWR-30 Dewar, DSPEC PLUS Digital Spectrometer, 138-G Marinelli Beaker How-To Guide

GammaVision-32 V5.2 is an integrated gamma spectroscopy data acquisition and spectral analysis software program that operates with the ease of the Windows-based operating system environment. By reading in this How-To Guide, you will learn the basics of GammaVision and begin making simple gamma-ray measurements. You will need a Standard Source (and the certificate information) for the calibration exercises carried out in the example.

PDF
Document
ORTEC GammaVision-32 V5.2 How-To Guide | Manualzz

Advertisement

Advertisement

/

Advertisement

Key features

  • Gamma spectroscopy analysis

  • Windows-based operation

  • Standard Source calibration

  • Efficiency calibration

  • Peak shape calibration

  • Sample analysis

  • Report generation

  • Preset count time

  • Auto background

  • Decay correction

Frequently asked questions

GammaVision-32 V5.2 is an integrated gamma spectroscopy data acquisition and spectral analysis software program that operates with the ease of the Windows-based operating system environment. It is designed to recognize a number of hardware configurations and enable only those features supported by the connected hardware.

GammaVision-32 V5.2 can support any mixture of the following types of units (with proper hardware configuration and installation): 916A, 917, 918A, 919, 920, 921, 926, 92X, NOMAD™ Plus, NOMAD, MicroNOMAD®, OCTÊTE PC®, TRUMP®, TRUMP-PCI, MicroACE™, DART®, DSPEC®, DSPEC Plus™, 92X-II, MatchMaker™, M3CA and other modules.

A Standard Source is a radioactive source with known nuclide energies and is used to calibrate the detector's energy, efficiency, and peak shape. This information is then used to accurately analyze unknown spectra.

The calibration process involves counting a standard source with known nuclide energies and instructing GammaVision to define channel numbers in terms of those energies. You can use the auto-calibration feature of GammaVision to calibrate energy and efficiency, and manually adjust the pole-zero feature for peak shape optimization.

To analyze a sample, you first need to fit the sample on the detector in the same manner as the standard source used for calibration. Then, you select Acquire, Start to begin counting the sample. Once the count is complete, you can analyze the spectrum and generate a report.

Preparing document for printing…