advertisement
FAMILY ET3500
CATALOGUE AND TECHNICAL DETAILED LISTS FOR AMPLIFIERS:
E2000-E3500-E7000-E10000-E15000-E31000
CATALOGUE AND TECHNICAL DETAILED LISTS FOR TRANSMITTERS:
ET2000-ET3500-ET7000-ET10000-ET15000-ET31000
The family ET3500 is arrange in several configurations from 2KW to 31KW in systems 1+0 e N+1X.
Edition 1
Rev. 5 – 22/10/2007
Cod. MAN0120
WARNING
The use of this device is subject to National Regulations
Elenos Srl
31/05/2006
31/05/2007
02/10/2007
19/10/2007
22/10/2007
REVIEW 1:
REVIEW 2:
REVIEW 3:
REVIEW 4:
REVIEW 5:
REVIEWS
Added outlines E2000 (pag. 22-23)
Modernized completely the handbook
Added designs of I block with quotas ET7000
Added designs of I block with quotas ET10000
Added designs of I block with quotas ET15000
Added designs of I block with quotas ET31000
Added heading to the entire manual
Added part scalability
Updated graphics
Dear User,
Firstly, thank you for choosing an product. products are solid state or thermionic tube transmitters that develop power from a minimum of 20W to a maximum of 30KW.
Great care has been taken during the design of the protection circuitry to ensure compatibility with products from other manufacturers. However the best performance is achieved when the equipment is used with other products manufactured by .
The unit has been designed to guarantee consistent performance over time, without the need for special maintenance. The need for this is minimised by regular functional checks of those components which are ventilated.
Operation of the unit is very easy and intuitive. Even so it is recommended that this manual and other relevant documentation is read carefully before any operation is attempted.
Customer Care
PRODUCTS
We design, realize, manufacture and market the following products :
Mos Fet transmitters up to
30KW
Tube Transmitters up to
30KW
Accessories: aerials, Stereo encoders, RDS, telemetry,
Changeover units, audio processors, Sound treatment
Our equipment are 99/5EC
European standard conform and respect the following
Directives:
EN60215
EN301 489-11
EN 302 018-2
ANNUAL TURNOVER
Among our customers we have the big Italian networks and an international distributor: Radio
Maria (our best customer) which owns: more than 1.000 radio stations in Italy: 82% of them use our equipment
500 radio stations distributed in more than 40 countries, 90% of them use our products.
Mainly in:
USA, Bolivia, Colombia,
Canada, Chile, Argentine,
Brazil, Equator, Salvador,
Guatemala, Mexico, Nicaragua,
Panama, Peru, Philippines,
Russia, Lithuania, Serbia,
Croatia, Albania, Austria, Malta,
Burkina Faso, Mali,
Mozambique, Tanzania, Togo,
Uganda, Zambia, France,
Germany, Lebanon, Poland,
Spain ,etc…
8.000.000
7.000.000
6.000.000
5.000.000
4.000.000
3.000.000
2.000.000
1.000.000
-
2000 2001 2002 2003 2004 2005 2006 2007
LOCAL SALES AND EXPORT
We sell our equipment all over the world thank to the avantgarde technology and excellent ratio quality/price.
Furthermore, our accurate selection on our dealers guarantees a good after-sales service.
Several patents cover our equipment, as:
Polynomial Coupler;
High-efficiency heat sink.
And many other that we use in cooperation with the University of Ferrara where our Research & development Manager teaches.
47%
45%
63%
46% 46%
41%
47%
53%
53%
55%
37%
54%
54%
59%
53%
47%
2000 2001 2002 2003 2004 2005 2006 2007
ITA
EST
39%
61%
Prodotti Standard
Prodotti "scalabili"
DISTRIBUTORS ALL AROUND THE
WORLD
Algeria
Arzerbaijan
Bulgaria
Cezch Republic
Congo
Cyprus
Gabon
Denmark
Hong Kong
Ireland
Lebanon
Morocco
Norway
Portugal
Senegal
Angola
Belize
Cabo Verde
Chile
Costa Rica
Estonia
Gambia
Dominican
Republic
Hungary
Israel
Lithuania
Mozambique
Pakistan
Romania
Syria
Argentina
Benin
Cameroon
China
Cote d'Ivoire
Finland
Greece
England
Indonesia
Jordan
Madagascar
Netherlands
Paraguay
Russia
Taiwan
Armenia
Brazil
Canada
Colombia
Croatia
France
Guatemala
Honduras
Iran
Kazakhistan
Malaysia
Nicaragua
Poland
Rwanda
Uganda
B R O A D C A S T T R A D E F
A I
I R S
A
T T E
N
D
E
D
:
:
�
IBC, Amsterdam – Holland
�
Le Radio!, Paris – France
�
NAB, Las Vegas – Nevada USA
�
Broadcast Asia – Singapore
�
BIRTV, Beijing – China
�
IBTS, Milan – Italy
�
ABERT, Brasilia – Brazil
�
CAPER, Buenos Aires – Argentina
�
TRBE, Moscow – Russia
�
Teleradio Broadcast, Kiew - Ukraine
�
IFEMA, Madrid – Spain
�
AFRICAST, Abuja – Nigeria
�
MEDIATECH, Johannesburg – South Africa
�
CONVENTION, Lisbon – Portugal
�
Broadcast India, Mumbai – India
And many more exhibitions attended by our dealers…
C
H
O
O
U
M
N
O
T
L
R
I
I
O
E S
G A
W
T
H
E
E
D
R E O
U
R E Q U
I
I P M E N T A
R
E
�
CE Europe
�
FCC United States
�
Argentina
�
Brazil
�
China
�
Russia
�
Bulgaria
�
Hungary
�
Romania
�
Senegal
�
Canada(homologation under process with Radio
Canada)
E L E N O S ’
’
G
O
A L S
Our aim is to create reliable transmitters for a better efficiency at reduced consumption and maintenance costs.
Our strategies to obtain this result are:
�
An accurate selection on quality of components o Papst and Sanyo Blowers o Lithium batteries, 10 years warranty o -25 +105 °C (60.000 at 60°C) Capacitors
�
“Conservative Strategy” for ex. 20 transistors instead of 16 for a 5KW amplifier, 12 instead of 10 for a 3KW amplifier.
�
Reduce the temperature of the equipment thanks to patented Heat
Sinks
�
Maximize the protections
�
Redundancy without “Single Point Failures”, power supply in parallel with “Current Sharing”
�
Derating, temperature, VSWR, over-voltage
�
Low Maintenance costs, dimensions, weight and consumption
�
Excellent after sales service
S C A L A B
I
I
L I
I T Y
F A M
I
I G L
I
I
A
E
T
S C A L A B
I
I
L I
I T Y
“ a
C d a v p a a n c t i i a t y g e o a o f f a t t f e f a c m h n i i i i l l c y a o l l f f i i p m r p o r d o u v c e t t s m i i e m n t t m o e f f d i b i a a t t s l l i i e c l l y p r e o v o d l l u v c t e t
” i i t t s p e r f f o r m a n c e
S C A L A B
I
I L
I
I T Y A D V A
N
T A G
E
S
•
•
A d i i n r y e c t t t e l l c y h o n n o l l a o l l l g l i i a c a p l l p i i a m r p a t t r u o e v s e m o f f e t t n h t t e o f f n a t t m h i i l l e y b a s i i c p r o d u c t t i i s t t r a n s f f e r r e d
•
•
S p r e a d i i n g k n o w l l e d g e a n d a u t o m a t t i i c m a i i n t t e n a n c e
•
•
I
I n t t e r c h a n g e a b i i l l i i t t y a n d i i n d e p e n d e n c e o f f i i n d i i v i i d u a l l m o d u l l e s
ET3500 FAMILY FM ICEFET TRANSMITTER
FROM 2Kw TO 60Kw
INTRODUCTION
The ET3500 FM transmitters family is built up by combining the E3500 model in order to obtain higher power outputs: from 2Kw to 60Kw in 1+0 and N+1X configurations. All models are W.B. 87,5MHz –
108MHz and their frequency is changeable without adjustment.
The amplifiers are accessible from the front panel, the RF, control and power supply connections have been designed to ease the replacement of a module with no service interruption. Every base module is completely redundant itself.
The base module of this family is the E3500 amplifier with the ETG exciters, all the constituents of the family share the same characteristics concerning RF modules, power supplies, control logics, protection systems, derating, and so on. For this reason this document always refers to the characteristics of the
E3500 amplifier and to the ETG exciter, same for all the other constituent of the family.
The main characteristics of the family:
Tropicalization and completely stainless steel manufacture on all series
Reduced dimensions and weight: it is the smallest and lightest transmitter of the world.
Easy installation
Convenient price
Low cost for maintenance
Reliability
SMS alarms
W.B.: ideal as a reserve (Dual Drive, Passive Reserve, Active Reserve, N+1)
Working at full power with one RF module missing, and keeps in operation with even one RF
Module functioning
Working at full power with one power supply missing, and keeps in operation with even one power supply functioning.
ICEFET technology
Total redundancy on all models
Remote diagnostic great ability
Control and system logic through touch-screen graphic interface
Connectivity
Power supply
Dual Exciter ETG100, ETG300, ETG500 and ETG1000
Conservative use of mosfet
No IPA (Intermediate Power Amplifier)
IPF (Intelligent Proportional Foldback)
IPC (Intelligent Power Control)
Efficiency optimization on the whole band
Fan speed proportional to temperature
RF thermal derating
Cooling system thermal derating
PSU current derating
RF amplifiers’ fault derating
Alarm storage management
Continuous training: Elenos offers a continuous training to its distributors with the aim of qualifying their professionalism and allowing them to supply the better technical assistance on its products.
Sales service and technical assistance: ELENOS relies one of the greatest distribution channel of the world. Each distributor is selected mainly for his quality of the technical support he can provide to the customer.
The main characteristics of the equipment are described here below:
ICEFET TECHNOLOGY
This technology led to the lowest functioning temperature of MOSFETs. Together with the use of a highefficiency heat sink (Elenos patent) a huge increase of reliability on MTBF is obtained.
TROPICALIZATION COMPLETELY STAINLESS STEEL MANUFACTURE
All mechanical parts are stainless steel, the electronic boards are treated with isolating varnish to protect against corrosion caused by salt deposit or humidity in general. Moreover, each electronic part that may be in contact with air flow has been protected with special protective screens.
TOTAL REDUNDANCY OF THE WHOLE SERIES
The ET3500 Family is conceived to be completely redundant.
The intrinsic redundancy of its equipment annuls each ”SINGLE-POINT-FAILURES” thanks to a “SOFT
FAILURE DESIGN” and to a sophisticated protection system allowing to stay «ON AIR» even in extreme working conditions.
If you analyze accurately the projects of many of the modern transmitters in the market, one realizes that they show “redundancy bottleneck” that is, parts of the transmitter that are not redundant, therefore more likely producing the interruption of the service if any of these parts goes faulty. Typical cases are fans, auxiliary power supplies, or medium stage amplifier or most frequently the control logic of the equipment.
In the ET3500 family each component s duplicated or multiplied to annul the redundancy bottleneck and prevent transmission interruption.
In the ELENOS ET3500 family the redundancy is on all series, there’s no additional cost for the purchase of optional parts. This is an important detail when evaluating a purchase, in facts, on most transmitters in the market today redundancy is optional, to be paid separately. An example is the IPA or the power supply, usually declared redundant from the project but in the end an overprice is requested to be paid.
WIDE BAND
The transmitter maintains optimal performances of power and efficiency on the whole band, no need for tuning (important characteristic when we are dealing with a reserve transmitter in N+1 systems).
REDUCED WEIGHT AND DIMENSIONS
The complete transmitter is built in a 7U-rack dimensions (3.5KW) and 40U (15KW), with a base smallest than 0,31mq. (length 50cm x depth 63 cm).
REMOTE DIAGNOSTIC GREAT ABILITY
The Hostlink standard protocol used in the equipment grants a secure management of a high quantity of information for the remote diagnostic.
The telemetry based on Hyperterminal allows an easy remote access from any PC no necessity of dedicated software installation.
CONTROL AND SYSTEM LOGIC THROUGH TOUCH-SCREEN GRAPHIC
INTERFACE
The SCU System Control Logic or the TCU Transmitter Control Logic analyse the operating parameters according t which it takes clever decisions for a better functioning of the transmitter. In this way it controls the output power stability, launch the VSWR derating, temperature and so on, to ease troubleshooting and store faulty conditions’ memory.
CONNECTIVITY:
the transmitter can be controlled through:
The local control logic (Color Touch Screen Display);
Local PC with Hyperterminal through the RS232 or RS485 ports;
Remote PC with Hyperterminal through a PSTN or GSM Modem;
Remote or local PC with SNMP;
Parallel interface;
For local or remote PCs a specific software is not necessary, because of the use of ANSI standard terminal (Hyperterminal) or Web Browser as Internet Explorer.
POWER SUPPLY
The power supply is the heart of any electronic device, for this reason, the redundant ones are standard built in each ELENOS amplifier.
The power supply is over-dimensioned, reliable, with PFC and voltage share, are at extended range.
Thanks to them the equipment works on supplies between 110VAC and 380VAC, both singlephase and three-phase.
The power supply room of the E3500 contains 3 power supplies of 2KW 50V 40° each.
The complete power supply case , therefore, produces a total of 6Kw 50V 120A exceeding for 20% the necessary total power to work at full scale. Thanks to power supplies redundancy, the transmitter delivers
2KW still with one damaged power supply, or at 1KW with two damaged power supplies.
The PFC reduces the harmonic emissions in the mains, improves the overall efficiency and the power factor of the equipment, that results 0,98.
The outputs 50 VDC of the three power supplies are connected in parallel and use the voltage share technology.
This technology guarantees that all power supplies deliver the same voltage in a way that none of them is overcharged and that temperature of all is the minimum possible, furthermore it improves the balance of the absorption on the three phases minimizing the voltage on the neutral to a value very near to 0.
ETG100, ETG300, ETG500 and ETG1000 EXCITERS
The ETG101, ETG300, ETG500 and ETG1000 are FM exciters solid state with output power constantly variable from 0 to the nominal power, in the band 87,5 – 108 MHz tuneable at steps of 1KHz from the
frontal panel through a LCD graphic interface, through which the user can analyse all operative parameters and program them through the ergonomic keyboard on the front panel.
The exciters of the ETG family are the state of art of FM broadcast, its warm and crystal sound - perceived from the first very listening – is confirmed by the measurements of the electric performances meaning the signal/noise ratio, distortion and the wide “Stereophonic Image”
DUAL EXCITER
In the ELENOS ET3500 family, all components and the softwares needed for the changeover between exciters are included in the combiner.
RF MODULE, CONSERVATIVE USE OF MOSFETs
The MOSFET used is the BLF278, it delivers alone 400W power. Our conservative choice to use it at
280W was aimed to give more reliability in case of overcurrent, excessive SWR or temperature.
NO IPA (Intermediate Power Amplifier)
The high power MOSFET transmitters in the market today use on average a “Medium Stage Driver” commonly defined IPA and go from 300-1000W. This amplifier represents the critical element of the chain because not redundant: in case of fault the user has the complete loss of service.
Elenos transmitters don’t use the IPA, so they annul every bottleneck in redundancy; this has been possible thanks to the wide choice of powers available in the ETG family from 101W to 1000W.
IPF (INTELLIGENT PROPORTIONAL FOLDBACK)
IPF is an intelligent system that varies the transmitter’s output power according to the mismatch condition of the load and permits to the transmitter to work also on loads highly mismatched.
IPC-INTELLIGENT POWER CONTROL
IPC maintains the output power within the 2% of the target power, independently from mains variations, from temperature or load.
The management of “IPC” power is based on the control of the VDS voltage supplied by the power supplies and the BIAS voltage supplied by two analogue outputs, -10/10V of the logic.
The amplifier, under correct functioning, maintains the set power with a tolerance of 30 W (+/-%).
The control algorithm, in normal functioning, leads to a 30V value the VDS voltage and increases the
BIAS voltage to join the targeted power set or saturation (10V). If there isn’t enough BIAS voltage to raise the amplifier to the requested power, the VDS voltage should be raised. This optimizes the efficiency of the
RF part: under high currents and reduced voltages MOSFETS work always at the maximum saturation level.
To reduce start-up time, if the power output moves away from the target power for more than 100 W, the increases of VBIAS and VDS are not unitary, but for the VBIAS increases or decreases of 400 mV are made
(the single step corresponds to 40 mV), and for the VDS of 500mV (with the correspondent step at 12,5 mV).
The management activates itself only if the forward power is higher than 25W, measured on the directional couplet, otherwise it maintains the VDS at the minimum value and the BIA at -4V.
The increase of VBIAS and VDS occurs only if the voltage delivered by the power supplies doesn’t overpass
42A each. This avoids a condition of instability in case of a damaged power supply.
EFFICIENCY OPTIMIZATION ON THE WHOLE BAND
The most important results obtained from the IPC functioning and the increase of the efficiency on the whole band and for all power levels set.
To keep high efficiency, means low temperature, decrease operation costs and improvement of reliability.
DERATING
DERATING is a mechanism of reduction of output power proportional to the entity of the fault occurred.
There are four main derating:
1. Thermic derating for RF amplifier when out of ventilation;
2. Thermic derating of PSU or RF amplifier;
3. Current PSU derating;
4. Derating for one or more of RF amplifier;
FAN SPEED PROPORTIONAL TO THE TEMPERATURE
In each 3.5KW amplifier module are 6 very-high-durability blowers, 100.000 MTBF hours. Their overdimensioning is such that the amplifier can work at full scale for an undetermined time even with 2 still blowers. Furthermore the intelligent control system of speed, contributes to their durability.
The functioning of the intelligent control of fans is the following: under the 45°C the fans work at 60%.
From 45°C to 65°C the fan speed is proportional to temperature and varies from 60% to 100%. From
65°C to 70% the fan speed varies proportionally from 100% to 120%.
On start-up or on the activation of the “on air” condition, fans run for 1 minute at their nominal value
(100%) or more if the temperature needs it, after this minute they reduce their speed at a fixed slope of
1% per second joining the “set point” connected to the equipment internal temperature.
RF THERMAL DERATING
The reaction of the IPC control logic in case of temperature increase up to derating is the following:
Overpassing the temperature of 70°C on the RF heatsink and of 72°C for the power supplies activates the thermal derating mode;
With active derating on, first, the target power is reduced to the 52% of the set power (2% more than -
3dB), this to avoid that the transmitter generates an alarm of 3dB.
The reduction of 1°C of the temperature from 70°C for RF or 72°C for PSU, while derating, increases the temperature of 1/10 of 48% of the target power. The output power is reduced to the target value if the temperature is lower or equal to 60°C for the RF or of 62°C for PSU. This avoids also the thermal derating condition, restoring the normal functioning of the equipment.
If temperature continues to rise despite derating, the output power is reduced again even below a
-3dB level, generating also the -3dB alarm.
Id the derating is not able to stop the temperature raise, when the threshold of 80°C is overpassed for the
RF or 77°C for PSU, turns off the power supplies, therefore the amplifier. The reset of the equipment occurs with a hysteresis of 5°C, so the functioning is reset respectively at 75°C for RF and 72°C for PSU.
The transmitter shut-down is managed with three block-outs, that means that after three times it tries to contain the temperature through the derating, the total block of the equipment is determined.
Notice: When the power supplies stop, stop of blowers is consequently caused, therefore the equipment will work without forced air-cooling.
COOLING SYSTEM THERMAL DERATING
The ALC logic reduces the output power to max.1600W in case of fast increase of temperature when fans get damaged.
Its functioning is the following:
If the output power red on the output directional coupler is higher than 1600W and the max absorbed current from the RF amplifier is higher than 5A, then the control is activated.
Derating starts therefore in the following cases:
-
-
If the average temperature on frontal and rear blocks of the amplifiers is increasing
If the average increase of module temperature is more than 2°C every 15 seconds
-
If the difference of temperature between frontal and rear blocks is less than 3°C
At derating activation the equipment starts to work at 16000W
The reset of derating condition for damaged fans occurs if the temperature decreases every 15 seconds of
2°C and if the difference of temperature between frontal and rear blocks is more than 3°C.
PSU CURRENT DERATING
When the delivered currents from the single power supply increase, the ALC logic act as follows:
A maximum current of a single power supply over 40,5° determines the current derating condition.
The algorithm of ALC management under normal functioning conditions is replaced by another where the control of the VDS and VBIAS is determined by the set power and by the current delivered by the power supply – with major priority – that is maintained around 40A.
The current derating condition is annulled if the set power returns to the target value and the maximum current absorbed by the single power supply is equal or lower than 40A.
If the current delivered by one power supply is lower than 1/10 of the maximum current supplied by the other power supplies and if the total current delivered is higher than 10A, the power supplies generate a malfunctioning signal, in order to make a diagnosis of faulty power supply.
RF AMPLIFIERS FAULT DERATING
In case one or more broken RF amplifiers, this is what the ALC logic behaves: the absorbed currents from the modules are detected by the SHUNT board. If the current value is lower than 1/10 of the maximum current delivered by the single RF amplifier, the power supplies have to give a
VDS higher than 30V (minimum value), the total current is higher than 2,5*12> 30A (n. of RF modules) and the forward power is over 500W. Under these conditions the modules are considered faulty.
Controls on the total current, on the VDS state and on forward power mask the alarm in case of low current value, due to output powers too low and/or absence of driving.
A table shows the maximum power deliverable in a pre-defined and constant way according to the active modules.
If the maximum power deliverable is the set target power or higher, an alarm for RF modules malfunctioning is shown, but the equipment still works correctly.
If it is lower instead, the equipment will show an active derating and a malfunction of the amplifiers.
The reset of the derating condition of the modules occurs when the fault disappears, when the current of each module returns over 2,5 A and after a delay of 60 s.
To avoid the number of SMS sent in case of fault, the equipment does not send SMS during derating, in fact, the equipment sends SMS (if active) only for the -3dB signal, that means when the delivered power is lower than 50% of the set target power.
6
7
8
9
10
11
12
2
3
4
5
N° of active modules
0
1
Maximum deliverable power
< 500W
< 500W
< 500W
< 500W
< 500W
700W
1100W
1500W
1900W
2300W
2700W
3100W
3500W
PROTECTIONS
The E3500 has been built with a protection system that puts together hardware protections with the performances of software protections.
ALARM LIST MANAGEMENT
It lists the sequence of the last 19 alarms with date and time for each alarm.
Permanent stored data, with checksum,
HARDWARE PROTECTIONS
This system is composed by an ultra fast protection that turns off MOSFETS through the bias is the VSWR overpasses 10% of the maximum power. In fact, the equipment is able to bear shortcircuit events or open circuits on the RF output without damage.
Independent fuse protection on each 300W MOSFET amplifier module.
Electronic fast and fuse protection on power supply of the blowers.
SOFTWARE PROTECTIONS – ALARM MANAGEMENT
The protection system is made of the Alarm management module
Physic and logic digital inputs are used in order to verify the alarm condition. The state of each input is sampled, then the condition is elaborated in a logic way with a combinatory net so to determine which is active: the alarm or the message.
The minimum time is 100ms.
The turn-off modalities are mainly the following:
STOP3BLOCKOUT
STOP
STOPNOTFAULT
RESETREQUIRED
REDPOWER
FAULT_LED
FAULT_B_LED
ON_AIR_B_LED
INHIBIT
HALF_POWER
INTLOCK
NO_MAINS
T_DERATING
I_DERATING
U_DERATING
Stops the equipment with Three Block Out
Stops the equipment without Three Block Out
Stops the equipment without FAULT
Requests a reset
Reduced power functioning
Still Red Led
Red Led Flashing at 1,5 Hz
Green led on air Flashing at 1,5 Hz
Amplifier inhibition alarm
-3dB functioning alarm
Amplifier block alarm
No mains presence alarm
Power reduction for temperature alarm
Power reduction for power supply currents alarm
Reduced power alarm for fast over-temperature on forced air- cooling
Reduced power alarm for fault on RF modules RF_MOD_DERATING
This module is repeatedly executed at equal priority of the ALC management in order to constantly verify if alarm causes occurs, so that to intervene in time.
The implementation is based on a table which describes the arrest nets, therefore the code is the same for all alarm and in case of new stops it doesn’t need changes.
ALARM LIST
Alarm reset
Persistent data checksum error.
Three block out.
Standby / on air.
-3dB.
Max reflected power.
Minimum -12V.
Message, alarm reset under process, output flags decides the reset of all stored alarms and no more active.
Message, the persistent data in eeprom have been lost and the equipment is configured with the default parameters.
Message, equipment blocked for consecutive faults, requests the reset from the user to allow restart.
Message, identifies that the amplifier is in stand-by mode ready to start without alarms.
Message, the amplifier delivers a power output lower than 3dB in respect to the target set. Further to the 5 seconds of mains delay there is also a delay of 55 seconds before start up.
It indicates a too high level of reflected power. It turns the equipment off in three block out.
Voltage level too low on -12V which prevents functioning of its protections. It turns the equipment off in three block out.
Anomaly on RF module, maximum deliverable power is reduced. RF Modules fault
RF Modules derating
RF thermal derating.
Output power reduced due to a broken RF module. If the set target power is lower than the one deliverable by the system with the remaining modules, this message does not appear.
Thermic anomaly on RF modules, reducing the maximum power output.
RF over temperature error. Maximum operating temperature overpassed and equipment turn off
PSUs fault error.
PSU current derating.
PSUs max current error.
PSUs thermal derating.
PSUs over temperature.
UNB OVERTEMPERATURE
MSG in three block out.
Malfunctioning of one or more power supplies. The fault is determined by a too low absorption (< 2A) of one or more power supplies comparing to the total current delivered (< 6A).
Overload of one or more power supplies and reduces the power output to reduce absorption. Fault is determined by a too-high absorption (> 40,5A) of one or more power supply.
Indicates a prolonged overload of one or more power supplies.
The fault is determined by a too high absorption (> 40,5A) of one or more power supplies for 60 seconds.
Indicates a power supply over-temperature: it reduces power.
Indicates a power supply over-temperature: it turns off the amplifier.
PSU / SHUNT communication error.
EXT DRV ENABLE A MSG
EXT COMM TIMEOUT
MSG
Malfunction of internal 485 BUS for communications between CPU and PSU/SHUNT.
External Interlock
Cooling system fault derating.
On air
Power up
Input hardware and active interlock.
Fast overheating of RF amplifier modules.
On air and properly functioning.
Stores in the list that the equipment has re started-up
ETG3500
ICEFET SOLID STATE FM TRANSMITTERS
Totally STAINLESS STEEL, electronic boards are Protected from Humidity and Inclement of
Tropical Weather.
All equipment undergo Rigorous Burn-In Process and quality controls.
Power sections were developed Over-Dimensioned with a conservative approach.
ICEFET Technology keeps temperature extremely low to increase the MTBF.
Fast hardware protections, further to Intelligent Proportional FoldBack of critical parameters like
VSWR and temperature.
Ventilation, power supplies, MOSFET and exciter are fully redundant to avoid any “Single Point
Failure” .
Our mission is to create the Most Reliable FM Transmitters Of The
World
MAIN CARACTERISTICS
Buil-In Exciter with Warm Crystal Sound:
S/N 85dB, Stereo Crosstalk 75dB, Harmonic Distortion 0,02%.
BUILT-IN STEREO GENERATOR
Stereo Crosstalk higher than 75dB thanks to the digitally controlled Pilot Tone Phase
AES/EBU INPUT
LIMITER DISORTIONLESS
The output of the limiter is double stage filtered
IT CAN BE USE BOTH AS EXCITER OR AS FINAL STAGE AMPLIFIER SEPARATELY
The 150W exciter output is connected to the RF amplifier input through an external jumper, this allows to use, if needed, both separately.
RS232/RS485 CONECTIVITY
OPERATING AT REDUCED POWER WITH ONE OR MORE BROKEN RF MODULES
OPERATING AT REDUCED POWER WITH ONE OR MORE BROKEN POWER SUPPLIES
ICE-FET:
Means Mosfet and heat sink maximum efficiency to reduce temperature, in order to obtain a higher MTBF. The result is unmatched in size and weight by any other producer
ALWAYS ON AIR: (FULLY REDUNDANT):
ALWAYS ON AIR: (FULLY REDUNDANT): The redundancy of this equipment prevents
SINGLE-POINT-FAILURES thanks to a SOFT FAILURE DESIGN and a protection system which keeps it « ON AIR» even in the most extreme working conditions.
IPC (Intelligent Power Control):
The IPC maintains constant the Output Power within 2% of the setting value, regardless of fluctuations in incoming AC line voltage, RF drive or load conditions.
IPF
The IPF allows the transmitter to stay on air into loads as poor as 3 to 1
BROAD BAND:
The transmitter keeps optimum performances of power and efficiency over the all Broad Band operation without needing of tuning what make it ideal for n+1 application
CONSTANT EFICIENCY:
The VPA and the Bias are both controlled to obtain maximum efficiency at any frequency and output power level. Keep the efficiency high means low heat, low operative cost, higher MTBF.
NO IPA:
In ELENOS transmitters, the IPA is always avoided. This choice eliminate one of the bottleneck in Redundancy frequently present on transmitters of this category.
EASY MAINTENACE:
all parts are easily accessible via the front panel(RF modules, electronic control boards) or via the rear panel (fans, combiners)
SMS ALARMS:
All alarms and event can be send by SMS
REDUCED SIZE AND WEIGHT:
Greatly reduced size and weight: the whole transmitter is contained in a 20-unit rack with a floor plan as less as 0,31 square meter!!! (50cm width x 86cm dept )
REMOTE DEEP DIAGNOSTIC CAPABILITY:
The industrial standard Hostlink Protocol allow to safety handle huge quantity of information to perform remote deep diagnosis.
WORLS WIDE SALES & SERVICE SUPPORT:
ELENOS is the FM manufacturer with one of the biggest distribution channel of the world. Each distributor is chose mainly by the technical support customer capability.
COMPOSITION & REDUNDANCY
0,1dB steps digital attenuator audio inputs and pilot tone
Stereo Generator
AES/EBU INPUT
Extremelly Linear Low Noise VCO
12 MOSFET Philips BLF278
3 Current Share combined 2.5KW
PFC switching Power Supply
6 Microprocessor Speed Controlled
Blowers
Microprocessor controlled
1 Output Harmonic Low Pass Filter
xx
BACK VIEW
TOP VIEW
BOTTOM VIEW
MAIN DISPLAY
FREQUENCY SETTING DISPLAY
POWER SETTING DISPLAY
TECHNICAL CARACTERISTICS
GENERAL DATA
Output Nominal Power
Operating band
Output Low-pass Filter
Corrosion
Internal bus RS232/RS485
Points of measure
Displayed Parameters
Adjustments
Microprocessor controlled
Power supply redundancy
Blower redundancy
Number of MOSFETs
Final stage technology
Transistor type
Number of power supplies
Dimensions: Rack units
Dimensions: Width
Dimensions: Height
Dimensions: Depth
Weight
3500 W adjustable
87.5 - 108 MHz
W.B. 87.5 MHz - 108 MHz
All mechanical parts are stainless steel
Yes
RF Sample-MPX Monitor
More than 50 parameters displayed on a LCD
From the frontal panel trough LCD
/from PC
Yes
Yes
Yes
12
ICEFET
BLF278 Philips
3
4 U
48,5 cm
17,6 cm
70 cm
43 Kg
Power supply units maximum weight 6 Kg
CONNETTORS
RF Output connector
RF Output connector exciter
RF Input connector
Input connectors LEFT & RIGHT
MPX Input connector
SCA Connector
Remote control connector
RS485/232 Connector
7/8''
BNC
BNC
XLR female
BNC female
BNC female
DB25 female
DB9 female
RF
Overall output power stability
Output impedance
Harmonic suppression
Spurious signal suppression
Driving power final stage
Input impedance final stage
Gain final stage
Software V.S.W.R. intervention
+/-0,1 dB
50 �
> 80 dB
> 80 dB
85 W
50 �
16 dB
350 W threshold
Fast V.S.W.R. intervention threshold 400 W
Asynchronous residual AM (typical values)
0,1 %
Synchronous residual AM (typical values)
RF Efficiency
Output nominal power
Maximum peak power
AUDIO
L/R Audio input level
L/R level adjustment
L/R Connector type
L/R Input Impedance
MPX audio input level
MPX level adjustment
MPX Connetor type
MPX Input impedance
PILOT level adjustment
PILOT Phase adjustment
SCA/RDS level adjustment
SCA/RDS Connector type
SCA/RDS Input Impedance
19KHz Output
STEREO/MPX easy changeover
AES/EBU Input option
PERFORMANCE EXCITER
Time of adjustment - frequency
Time of adjustment - power
MTBF
Programmed Maintenance
Intermodulation distortion
Frequency deviaton
Frequency steps
THD+N
Pre-emphasis
FM S/N MPX FCC
FM S/N STEREO CCIR Weight
FM S/N STEREO CCIR Unweight
Mono frequency response
MPX frequency response
0,2 %
65% typ.
3500 W Adjustable with continuity
3800 W
+12/-12 dBm to produce 75KHz standard deviation
Soft adjust 0,1dBm steps from front panel
Balanced XLR
Selectable 10K- 600�
+12/-12 dBm to produce 75KHz standard deviation
Soft adjust 0,1dBm steps from front panel
Unbalanced BNC
5K� selectable
Soft adjust 0,1dBm steps from front panel
Soft adjust 0,1dBm steps from front panel
Soft adjust 0,1dBm steps from front panel
Unbalanced BNC
10K�
Yes
Yes
Optional (External adapter)
<0,1 minute
<0,1 minute
10 Years
5 Years
<0.05% Measured with two of tones
1KHz & 1.3KHz, ratio 1:1 at 100% modulation
+/- 75 KHz 0.1dB steps adjustable
10 KHz
<0.03% @ 1KHz
50/75 microseconds +/-0,1dB
82 dB 20Hz - 23KHz - 50uS - ref @
53KHz - RMS
72 dB Weight-ref@53KHz-Qpk
72 dB Unweight-ref@53KHz-QPk
+/-0.15 dB 30Hz - 15KHz
+/-0.1 dB 30Hz - 100KHz, -45dB at
19 KHz
Stereo frequency response
SCA1,2,3 frequency response
Type of modulation
Stereo separation
Pilot tone frequency
Pilot tone deviation
Pilot tone frequency stability
Attenuation at 19KHz
Phase Response
Frequency stability
Time for starting up
Time for starting up
Modulation Capabilities
POWER SUPPLY
Power supply
Power consumption
Magneto-thermic curve
Current Consumption
@220VAC/single phase
Magneto-thermic capacity
@220VAC/single phase
Conductor Size @220VAC/single phase
Conductor Size @220VAC/single phase
Current Consumption
@220VAC/three phase
Magneto-thermic capacity
@220VAC/three phase
Conductor Size @220VAC/three phase
Conductor Size @220VAC/three phase
Current Consumption
@380VAC/three phase
Magneto-thermic capacity
@380VAC/three phase
Conductor Size @380VAC/three phase
Conductor Size @380VAC/three phase
COOLING SYSTEM
Cooling flow (m3/h) Variable from 300 to 600 m3/h
10 sqrt.mm
7 AWG
13 Amp.
20 Amp.
6 sqrt.mm
9 AWG
8 Amp.
13 Amp.
4 sqrt.mm
11 AWG
+/-0.15 dB 30Hz - 15KHz
+/-1 dB 20KHz - 100KHz, -45dB at
19KHz
F3 Direct FM modulation of the RF oscillator in fundamental frequency
> 60 dB @ 1KHz
19 KHz
7,5 KHz Adjustable
+/-1 Hz
> 45 dB
0.1 degreeFrom linear phase; 53kHz to 100kHz
1 ppm from 0 to +40°C
30 sec. from OFF/ON
1 sec. from interlock close
+/-200 KHz
110, 220, 380 Threephasesinglephase 50-60Hz VAC
5 KVA
D
23 Amp.
32 Amp.
ENVIRONMENT
Air temperature increase between output /input
Cooling system
Humidity range (operating)
Humidity range (non operating)
Altitude range (operating)
Altitude range (non operating)
TELECONTROL & TELEMETRY
Remote control
Remote Control at clean contacts
SNMP option
REGULATIONS CONFORMITY
High frequency radiations from the enclosure
Functionning type
Electromagnetic fields immunity
CE Mark
17 °C
Forced air-cooling through 6 axial fans
Temperature range (operating) 0 - +45 °C
Temperature range (non operating) -20 - +70 °C
95% at 40 °C
90% at 65 °C
>4600 meters
>15000 meters
Yes
Yes
Under development
Below limit imposed by technical regulations.
h24 uninterrupted
Higher than specified by laws on electromagnetic fields compatibility
Conform to 1999/5/CE European
Directive
MANUFACTURING DATA
Year of the model
Spares availability guaranteed for
PRE- & POST- MAINTENANCE
Recurrence
Blower Replacement recurrence
Air blowers quantity and prices
Lithium batteris replacement recurrence
Batteries
Time to realize the preventive maintenance every 4 years
Time to realize the preventive maintenance very 8 years
Level and number of technician for maintenance
Electrical safety
Average repair time (change of an
RF module or power supply)
SET
Installation manual
User manual
Tests report
GUARANTY CONDITIONS
2007
10 years from the date of purchase
4/8 years
4 years
6
10 years
Yes, only for alarm list storage
1 Hour
2 Hours
1 technician
EN60215 (Standard CE)
1 Hours
Yes
Yes
Yes
The equipment provided by Elenos srl covered under warranty of 24 months from the date of purchase of the product; That period is meant to be applied to the original that any subsequent buyers.
SPAREPARTS
SPARE PARTS MAINTENACE PREVENTIVE
Euro: 3
652.741
2
Power Supply #1 (COD: 2KWPFC-
SER)
Euro:
52.3052
6
Fuse Kit
RF Fan (COD: 1VENT026)
Fuse Kit E3000
Battery
SPARE PARTS CORRECTIVE MAINTENACE
Euro: 0 12 RF Amplifier Module (COD:
ERK_20044_0)
YES
Euro:
256.51
12 Complete RF Amplifier board with
Mosfets #1 (COD: E3K 2A044_0)
Euro:
206
12 Mosfet #1 (COD: 2QRF0012
(BLF278))
Euro:
77.2124
1 CPU (COD: E3K 8A044_0)
Euro:
30.175
1 Display (COD: 2DYL0001)
Euro:
113.771
6
1 Scheda shunt (COD: E3K 4A044_1)
Euro: 15 16
Combiner Type #1
Absorber Resistors #1 (COD:
2RAF1007)
E3K 1A044_0
Euro:
17.9218
10 front panel
Output armonic filter L.P. FILTER
Temperature sensor board #1 (COD:
E3K 6A044_0)
9MOD2800_0
E3KPZ003
Euro:
12.05
3 Temperature sensor board #2 (COD:
E2K 7A000_1)
Euro:
104.2
1 Fan Board (COD: E3K_3A044_0)
Euro: 0 1 Scheda Interconnessioni (COD:
E3K_9A044_0)
Euro: 0 1 Scheda Testina di Lettura (COD:
E3K_5A044_0)
Euro: 0 1 Scheda Splitter #1 (COD:
E3K_0A044_0)
Euro: 0 1 Scheda I/O Digitale (COD:
CHG12A753_0)
Euro: 0 1 Scheda Pannello Pulsanti (COD:
E3K_7A044_0)
Euro: 0 1 Sezionatore Magnetico Monofase
(COD: 1SZ00037)
Euro: 0 1 Sezionatore Magnetico Trifase (COD:
1SZ00036)
Cables RG178 (50 Ohm) #2 CAB0150_0
Cables RG179 (75 Ohm) #2 CAB0149_1
0
ET2500
ICEFET SOLID STATE FM TRANSMITTERS
Totally STAINLESS STEEL, electronic boards are Protected from Humidity and Inclement of
Tropical Weather.
All equipment undergo Rigorous Burn-In Process and quality controls.
Power sections were developed Over-Dimensioned with a conservative approach.
ICEFET Technology keeps temperature extremely low to increase the MTBF.
Fast hardware protections, further to Intelligent Proportional FoldBack of critical parameters like
VSWR and temperature.
Ventilation, power supplies, MOSFET and exciter are fully redundant to avoid any “Single Point
Failure” .
Our mission is to create the Most Reliable FM Transmitters Of The
World
MAIN CARACTERISTICS
OPERATING AT REDUCED POWER WITH ONE OR MORE BROKEN RF MODULES
OPERATING AT REDUCED POWER WITH ONE OR MORE BROKEN POWER SUPPLIES
ICE-FET:
Means Mosfet and heat sink maximum efficiency to reduce temperature, in order to obtain a higher MTBF. The result is unmatched in size and weight by any other producer
ALWAYS ON AIR: (FULLY REDUNDANT):
ALWAYS ON AIR: (FULLY REDUNDANT): The redundancy of this equipment prevents
SINGLE-POINT-FAILURES thanks to a SOFT FAILURE DESIGN and a protection system which keeps it « ON AIR» even in the most extreme working conditions.
IPC (Intelligent Power Control):
The IPC maintains constant the Output Power within 2% of the setting value, regardless of fluctuations in incoming AC line voltage, RF drive or load conditions.
IPF
The IPF allows the transmitter to stay on air into loads as poor as 3 to 1
BROAD BAND:
The transmitter keeps optimum performances of power and efficiency over the all Broad Band operation without needing of tuning what make it ideal for n+1 application
CONSTANT EFICIENCY:
The VPA and the Bias are both controlled to obtain maximum efficiency at any frequency and output power level. Keep the efficiency high means low heat, low operative cost, higher MTBF.
NO IPA:
In ELENOS transmitters, the IPA is always avoided. This choice eliminate one of the bottleneck in Redundancy frequently present on transmitters of this category.
EASY MAINTENACE:
all parts are easily accessible via the front panel(RF modules, electronic control boards) or via the rear panel (fans, combiners)
BIG COLOUR TOUCH SCREEN GRAPHIC DISPLAY:
User friendly graphic interface allow access to control and diagnosis parameters
SMS ALARMS:
All alarms and event can be send by SMS
REDUCED SIZE AND WEIGHT:
Greatly reduced size and weight: the whole transmitter is contained in a 20-unit rack with a floor plan as less as 0,31 square meter!!! (50cm width x 86cm dept )
REMOTE DEEP DIAGNOSTIC CAPABILITY:
The industrial standard Hostlink Protocol allow to safety handle huge quantity of information to perform remote deep diagnosis.
WORLS WIDE SALES & SERVICE SUPPORT:
ELENOS is the FM manufacturer with one of the biggest distribution channel of the world. Each distributor is chose mainly by the technical support customer capability.
COMPOSITION & REDUNDANCY
8 MOSFET Philips BLF278
2 Current Share combined 2.5KW
PFC switching Power Supply
5 Microprocessor Speed Controlled
Blowers
Microprocessor controlled
1 Output Harmonic Low Pass Filter aaaa
xx
BACK VIEW
TOP VIEW
BOTTOM VIEW
MAIN CARACTERISTICS
COMPOSED
GENERAL DATA
Exciter
Amplifiers
Mounted in 19" standard rack
Number of racks
Output Nominal Power
Operating band
Output Low-pass Filter
Corrosion
Internal bus RS232/RS485
Points of measure
Displayed Parameters
Adjustments
Microprocessor controlled
Power supply redundancy
Blower redundancy
Number of MOSFETs
Final stage technology
Transistor type
Number of power supplies
Dimensions: Rack units
Dimensions: Width
Dimensions: Height
Dimensions: Depth
Weight
RF Modules maximum weight
Power supply units maximum weight 6 Kg
2000 W adjustable
87.5 - 108 MHz
W.B. 87.5 MHz - 108 MHz
All mechanical parts are stainless steel
Yes
RF Sample-MPX Monitor
More than 50 parameters displayed on a LCD
From the frontal panel trough LCD
/from PC
Yes
Yes
Yes
8
ICEFET
BLF278 Philips
2
4+3 U
48,5 cm
(17,6+13,5cm.) Tot. 31,1 cm
70 cm
(43+22Kg.) Tot.75 Kg
35 Kg
CONNETTORS
ETG101
E2000
No
Optional
RF Output connector
RF Input connector
Input connectors LEFT & RIGHT
MPX Input connector
SCA Connector
Remote control connector
RS485/232 Connector
7/8''
N
XLR female
BNC female
BNC female
DB25
DB9
RF
Overall output power stability
Output impedance
Harmonic suppression
Spurious signal suppression
Driving power final stage
Input impedance final stage
Gain final stage
+/-0,1 dB
50 �
> 70 dB
> 80 dB
80 W
50 �
16 dB
Software V.S.W.R. intervention threshold
200 W
Fast V.S.W.R. intervention threshold 220 W
Asynchronous residual AM (typical 0,1 % values)
Synchronous residual AM (typical values)
RF Efficiency
Output nominal power
Maximum peak power
0,2 %
65% typ.
2500 W Adjustable with continuity
2600 W
AUDIO
L/R Audio input level
L/R level adjustment
L/R Connector type
L/R Input Impedance
MPX audio input level
MPX level adjustment
MPX Connetor type
MPX Input impedance
PILOT level adjustment
SCA/RDS Connector type
SCA/RDS Input Impedance
19KHz Output
STEREO/MPX easy changeover
AES/EBU Input option
PERFORMANCE EXCITER
Time of adjustment - frequency
Time of adjustment - power
MTBF
Programmed Maintenance
Intermodulation distortion
Frequency deviaton
Frequency steps
THD+N
Pre-emphasis
FM S/N MPX FCC
FM S/N STEREO CCIR Weight
FM S/N STEREO CCIR Unweight
Mono frequency response
MPX frequency response
+12/-12 dBm to produce 75KHz standard deviation
Soft adjust 0,1dBm steps from front panel
Balanced XLR
Selectable 10K- 600�
+12/-12 dBm to produce 75KHz standard deviation
Soft adjust 0,1dBm steps from front panel
Unbalanced BNC
5K� selectable
Adjustable Trimmer
Unbalanced BNC
10K�
Yes
Yes
Optional (External adapter)
< 1 minute
< 1 minute
10 Years
5 Years
<0.05% Measured with two of tones
1KHz & 1.3KHz, ratio 1:1 at 100% modulation
+/- 75 KHz 0.1dB steps adjustable
10 KHz
<0.03% @ 1KHz
50/75 microseconds +/-0,1dB
82 dB 20Hz - 23KHz - 50uS - ref @
53KHz - RMS
72 dB Weight-ref@53KHz-Qpk
72 dB Unweight-ref@53KHz-QPk
+/-0.15 dB 30Hz - 15KHz
+/-0.1 dB 30Hz - 100KHz, -45dB at
19 KHz
Stereo frequency response
SCA1,2,3 frequency response
Type of modulation
Stereo separation
Pilot tone frequency
Pilot tone deviation
Pilot tone frequency stability
Attenuation at 19KHz
Phase Response
Frequency stability
Time for starting up
Time for starting up
Modulation Capabilities
POWER SUPPLY
Power supply
Power consumption
Magneto-thermic curve
Current Consumption
@220VAC/single phase
Magneto-thermic capacity
@220VAC/single phase
Conductor Size @220VAC/single phase
Conductor Size @220VAC/single phase
Current Consumption
@220VAC/three phase
Magneto-thermic capacity
@220VAC/three phase
Conductor Size @220VAC/three phase
Conductor Size @220VAC/three phase
Current Consumption
@380VAC/three phase
Magneto-thermic capacity
@380VAC/three phase
Conductor Size @380VAC/three phase
Conductor Size @380VAC/three phase
COOLING SYSTEM
Cooling flow (m3/h) Variable from 400 to 800 m3/h
6 sqrt.mm
9 AWG
9 Amp.
16 Amp.
4 sqrt.mm
11 AWG
5 Amp.
10 Amp.
2,5 sqrt.mm
13 AWG
+/-0.15 dB 30Hz - 15KHz
+/-1 dB 20KHz - 100KHz, -45dB at
19KHz
F3 Direct FM modulation of the RF oscillator in fundamental frequency
> 60 dB @ 1KHz
19 KHz
7,5 KHz Adjustable
+/-1 Hz
> 45 dB
0.1 degreeFrom linear phase; 53kHz to 100kHz
1 ppm from 0 to +40°C
30 sec. from OFF/ON
1 sec. from interlock close
+/-250 KHz
110,220, 380 Threephasesinglephase 50-60Hz VAC
5 KVA
D
15 Amp.
25 Amp.
ENVIRONMENT
Air temperature increase between output /input
Cooling system
Humidity range (operating)
Humidity range (non operating)
Altitude range (operating)
Altitude range (non operating)
TELECONTROL & TELEMETRY
Remote control
Remote Control at clean contacts
SNMP option
REGULATIONS CONFORMITY
High frequency radiations from the enclosure
Functionning type
Electromagnetic fields immunity
CE Mark
17 °C
Forced air-cooling
Temperature range (operating) 0 - +45 °C
Temperature range (non operating) -20 - +70 °C
95% at 40 °C
90% at 65 °C
>4600 meters
>15000 meters
Yes
Yes
Under development
Below limit imposed by technical regulations.
h24 uninterrupted
Higher than specified by laws on electromagnetic fields compatibility
Conform to 1999/5/CE European
Directive
MANUFACTURING DATA
Year of the model
Spares availability guaranteed for
PRE- & POST- MAINTENANCE
Recurrence
Blower Replacement recurrence
Air blowers quantity and prices
Lithium batteris replacement recurrence
Batteries
Time to realize the preventive maintenance every 4 years
Time to realize the preventive maintenance very 8 years
Level and number of technician for maintenance
Electrical safety
Average repair time (change of an
RF module or power supply)
SET
Power supply cable
Installation manual
User manual
Maintenance manual
Tests report
2005
10 years from the date of purchase
4/8 years
4 years
6
10 years
Yes, only for alarm list storage
1 Hour
2 Hours
1 technician
EN60215 (Standard CE)
1 Hours
Yes
Yes
Yes
Yes
Yes
The equipment provided by Elenos srl covered under warranty of 24 months from the date of purchase of the product; That period is meant to be applied to the original that any subsequent buyers.
MAIN CARACTERISTICS
SPARE PARTS MAINTENACE PREVENTIVE
Power Supply #1 (COD: 2KWPFC-
SER)
Fuse Kit
RF Fan (COD: 1VENT026)
Fuse Kit E3000
Battery
SPARE PARTS CORRECTIVE MAINTENACE
RF Amplifier Module (COD:
ERK_20044_0)
YES
Complete RF Amplifier board with
Mosfets #1
Mosfet #1 (COD: 2QRF0012
(BLF278))
E3K 2A044_0
CPU (COD: E3K 8A044_0)
Display (COD: 2DYL0001)
Scheda shunt (COD: E3K 4A044_1)
Combiner Type #1
Absorber Resistors #1 (COD:
2RAF1007)
E3K 1A044_0 front panel
Output armonic filter L.P. FILTER
Temperature sensor board #1 (COD:
E3K 6A044_0)
9MOD2800_0
E3KPZ003
Temperature sensor board #2 (COD:
E2K 7A000_1)
Fan Board (COD: E3K_3A044_0)
Scheda Interconnessioni (COD:
E3K_9A044_0)
Scheda Testina di Lettura (COD:
E3K_5A044_0)
Scheda Splitter #1 (COD:
E3K_0A044_0)
Scheda I/O Digitale (COD:
CHG12A753_0)
Scheda Pannello Pulsanti (COD:
E3K_7A044_0)
Sezionatore Magnetico Monofase
(COD: 1SZ00037)
Sezionatore Magnetico Trifase (COD:
1SZ00036)
Cables RG178 (50 Ohm) #2 CAB0150_0
Cables RG179 (75 Ohm) #2 CAB0149_1
0
ET3500
ICEFET SOLID STATE FM TRANSMITTERS
Totally STAINLESS STEEL, electronic boards are Protected from Humidity and Inclement of
Tropical Weather.
All equipment undergo Rigorous Burn-In Process and quality controls.
Power sections were developed Over-Dimensioned with a conservative approach.
ICEFET Technology keeps temperature extremely low to increase the MTBF.
Fast hardware protections, further to Intelligent Proportional FoldBack of critical parameters like
VSWR and temperature.
Ventilation, power supplies, MOSFET and exciter are fully redundant to avoid any “Single Point
Failure” .
Our mission is to create the Most Reliable FM Transmitters Of The
World
MAIN CARACTERISTICS
OPERATING AT REDUCED POWER WITH ONE OR MORE BROKEN RF MODULES
OPERATING AT REDUCED POWER WITH ONE OR MORE BROKEN POWER SUPPLIES
ICE-FET:
Means Mosfet and heat sink maximum efficiency to reduce temperature, in order to obtain a higher MTBF. The result is unmatched in size and weight by any other producer
ALWAYS ON AIR: (FULLY REDUNDANT):
ALWAYS ON AIR: (FULLY REDUNDANT): The redundancy of this equipment prevents
SINGLE-POINT-FAILURES thanks to a SOFT FAILURE DESIGN and a protection system which keeps it « ON AIR» even in the most extreme working conditions.
IPC (Intelligent Power Control):
The IPC maintains constant the Output Power within 2% of the setting value, regardless of fluctuations in incoming AC line voltage, RF drive or load conditions.
IPF
The IPF allows the transmitter to stay on air into loads as poor as 3 to 1
BROAD BAND:
The transmitter keeps optimum performances of power and efficiency over the all Broad Band operation without needing of tuning what make it ideal for n+1 application
CONSTANT EFICIENCY:
The VPA and the Bias are both controlled to obtain maximum efficiency at any frequency and output power level. Keep the efficiency high means low heat, low operative cost, higher MTBF.
NO IPA:
In ELENOS transmitters, the IPA is always avoided. This choice eliminate one of the bottleneck in Redundancy frequently present on transmitters of this category.
EASY MAINTENACE:
all parts are easily accessible via the front panel(RF modules, electronic control boards) or via the rear panel (fans, combiners)
BIG COLOUR TOUCH SCREEN GRAPHIC DISPLAY:
User friendly graphic interface allow access to control and diagnosis parameters
SMS ALARMS:
All alarms and event can be send by SMS
REDUCED SIZE AND WEIGHT:
Greatly reduced size and weight: the whole transmitter is contained in a 20-unit rack with a floor plan as less as 0,31 square meter!!! (50cm width x 86cm dept )
REMOTE DEEP DIAGNOSTIC CAPABILITY:
The industrial standard Hostlink Protocol allow to safety handle huge quantity of information to perform remote deep diagnosis.
WORLS WIDE SALES & SERVICE SUPPORT:
ELENOS is the FM manufacturer with one of the biggest distribution channel of the world. Each distributor is chose mainly by the technical support customer capability.
COMPOSITION & REDUNDANCY
12 MOSFET Philips BLF278
3 Current Share combined 2.5KW
PFC switching Power Supply
6 Microprocessor Speed Controlled
Blowers
Microprocessor controlled
1 Output Harmonic Low Pass Filter
aaaa
xx
BACK VIEW
TOP VIEW
BOTTOM VIEW
MAIN CARACTERISTICS
COMPOSED
GENERAL DATA
Exciter
Amplifiers
Number of E3000 Amplifiers
Mounted in 19" standard rack
Number of racks
Output Nominal Power
Operating band
Output Low-pass Filter
Corrosion
Internal bus RS232/RS485
Points of measure
Displayed Parameters
Adjustments
Microprocessor controlled
Power supply redundancy
Blower redundancy
Number of MOSFETs
Final stage technology
Transistor type
Number of power supplies
Dimensions: Rack units
Dimensions: Width
Dimensions: Height
Dimensions: Depth
Weight
RF Modules maximum weight
Power supply units maximum weight 6 Kg
3000 W adjustable
87.5 - 108 MHz
W.B. 87.5 MHz - 108 MHz
All mechanical parts are stainless steel
Yes
RF Sample-MPX Monitor
More than 50 parameters displayed on a LCD
From the frontal panel trough LCD
/from PC
Yes
Yes
Yes
12
ICEFET
BLF278 Philips
3
4+3 U
48,5 cm
(17,6+13,5cm.) Tot. 31,1 cm
70 cm
(43+22Kg.) Tot.75 Kg
35 Kg
CONNETTORS
ETG101
E3000
1
No
Optional
RF Output connector
RF Input connector
Input connectors LEFT & RIGHT
MPX Input connector
SCA Connector
Remote control connector
RS485/232 Connector
7/8''
N
XLR female
BNC female
BNC female
DB25
DB9
RF
Overall output power stability
Output impedance
Harmonic suppression
Spurious signal suppression
Driving power final stage
Input impedance final stage
+/-0,1 dB
50 �
> 70 dB
> 80 dB
80 W
50 �
Gain final stage
Software V.S.W.R. intervention
16 dB
300 W threshold
Fast V.S.W.R. intervention threshold 330 W
0,1 % Asynchronous residual AM (typical values)
Synchronous residual AM (typical values)
0,2 %
RF Efficiency
Output nominal power
Maximum peak power
65% typ.
3500 W Adjustable with continuity
3700 W
AUDIO
L/R Audio input level
L/R level adjustment
L/R Connector type
L/R Input Impedance
MPX audio input level
MPX level adjustment
MPX Connetor type
MPX Input impedance
PILOT level adjustment
SCA/RDS Connector type
SCA/RDS Input Impedance
19KHz Output
STEREO/MPX easy changeover
AES/EBU Input option
PERFORMANCE EXCITER
Time of adjustment - frequency
Time of adjustment - power
MTBF
Programmed Maintenance
Intermodulation distortion
Frequency deviaton
Frequency steps
THD+N
Pre-emphasis
FM S/N MPX FCC
FM S/N STEREO CCIR Weight
FM S/N STEREO CCIR Unweight
Mono frequency response
+12/-12 dBm to produce 75KHz standard deviation
Soft adjust 0,1dBm steps from front panel
Balanced XLR
Selectable 10K- 600�
+12/-12 dBm to produce 75KHz standard deviation
Soft adjust 0,1dBm steps from front panel
Unbalanced BNC
5K� selectable
Adjustable Trimmer
Unbalanced BNC
10K�
Yes
Yes
Optional (External adapter)
< 1 minute
< 1 minute
10 Years
5 Years
<0.05% Measured with two of tones
1KHz & 1.3KHz, ratio 1:1 at 100% modulation
+/- 75 KHz 0.1dB steps adjustable
10 KHz
<0.03% @ 1KHz
50/75 microseconds +/-0,1dB
82 dB 20Hz - 23KHz - 50uS - ref @
53KHz - RMS
72 dB Weight-ref@53KHz-Qpk
72 dB Unweight-ref@53KHz-QPk
+/-0.15 dB 30Hz - 15KHz
MPX frequency response
Stereo frequency response
SCA1,2,3 frequency response
Type of modulation
Stereo separation
Pilot tone frequency
Pilot tone deviation
Pilot tone frequency stability
Attenuation at 19KHz
Phase Response
Frequency stability
Time for starting up
Time for starting up
Modulation Capabilities
POWER SUPPLY
Power supply
Power consumption
Magneto-thermic curve
Current Consumption
@220VAC/single phase
Magneto-thermic capacity
@220VAC/single phase
Conductor Size @220VAC/single phase
Conductor Size @220VAC/single phase
Current Consumption
@220VAC/three phase
Magneto-thermic capacity
@220VAC/three phase
Conductor Size @220VAC/three phase
Conductor Size @220VAC/three phase
Current Consumption
@380VAC/three phase
Magneto-thermic capacity
@380VAC/three phase
Conductor Size @380VAC/three phase
COOLING SYSTEM
Conductor Size @380VAC/three phase
+/-0.1 dB 30Hz - 100KHz, -45dB at
19 KHz
+/-0.15 dB 30Hz - 15KHz
+/-1 dB 20KHz - 100KHz, -45dB at
19KHz
F3 Direct FM modulation of the RF oscillator in fundamental frequency
> 60 dB @ 1KHz
19 KHz
7,5 KHz Adjustable
+/-1 Hz
> 45 dB
0.1 degreeFrom linear phase; 53kHz to 100kHz
1 ppm from 0 to +40°C
30 sec. from OFF/ON
1 sec. from interlock close
+/-250 KHz
110,220, 380 Threephasesinglephase 50-60Hz VAC
5 KVA
D
23 Amp.
32 Amp.
10 sqrt.mm
7 AWG
13 Amp.
20 Amp.
6 sqrt.mm
9 AWG
8 Amp.
13 Amp.
4 sqrt.mm
11 AWG
Cooling flow (m3/h)
Air temperature increase between output /input
Cooling system
ENVIRONMENT
Humidity range (operating)
Humidity range (non operating)
Altitude range (operating)
Altitude range (non operating)
TELECONTROL & TELEMETRY
Remote control
Remote Control at clean contacts
SNMP option
REGULATIONS CONFORMITY
High frequency radiations from the enclosure
Functionning type
Electromagnetic fields immunity
CE Mark
Forced air-cooling through 6 axial fans
Temperature range (operating) 0 - +45 °C
Temperature range (non operating) -20 - +70 °C
95% at 40 °C
90% at 65 °C
>4600 meters
>15000 meters
Yes
Yes
Under development
Below limit imposed by technical regulations.
h24 uninterrupted
Higher than specified by laws on electromagnetic fields compatibility
Conform to 1999/5/CE European
Directive
MANUFACTURING DATA
Year of the model
Spares availability guaranteed for
PRE- & POST- MAINTENANCE
Recurrence
Blower Replacement recurrence
Air blowers quantity and prices
Lithium batteris replacement recurrence
Batteries
Time to realize the preventive maintenance every 4 years
Time to realize the preventive maintenance very 8 years
Level and number of technician for maintenance
Electrical safety
Average repair time (change of an
RF module or power supply)
SET
Power supply cable
Installation manual
User manual
Maintenance manual
Variable from 400 to 800 m3/h
17 °C
2005
10 years from the date of purchase
4/8 years
4 years
6
10 years
Yes, only for alarm list storage
1 Hour
2 Hours
1 technician
EN60215 (Standard CE)
1 Hours
Yes
Yes
Yes
Yes
The equipment provided by Elenos srl covered under warranty of 24 months from the date of purchase of the product; That period is meant to be applied to the original that any subsequent buyers.
Tests report
Troubleshooting manual
Yes
Yes
MAIN CARACTERISTICS
SPARE PARTS MAINTENACE PREVENTIVE
Power Supply #1 (COD: 2KWPFC-
SER)
Fuse Kit
RF Fan (COD: 1VENT026)
Fuse Kit E3000
Battery
SPARE PARTS CORRECTIVE MAINTENACE
RF Amplifier Module (COD:
ERK_20044_0)
YES
Complete RF Amplifier board with
Mosfets #1 (COD: E3K 2A044_0)
Mosfet #1 (COD: 2QRF0012
(BLF278))
CPU (COD: E3K 8A044_0)
Display (COD: 2DYL0001)
Scheda shunt (COD: E3K 4A044_1)
Combiner Type #1
Absorber Resistors #1 (COD:
2RAF1007)
E3K 1A044_0 front panel
Output armonic filter L.P. FILTER
Temperature sensor board #1 (COD:
E3K 6A044_0)
9MOD2800_0
E3KPZ003
Temperature sensor board #2 (COD:
E2K 7A000_1)
Fan Board (COD: E3K_3A044_0)
Scheda Interconnessioni (COD:
E3K_9A044_0)
Scheda Testina di Lettura (COD:
E3K_5A044_0)
Scheda Splitter #1 (COD:
E3K_0A044_0)
Scheda I/O Digitale (COD:
CHG12A753_0)
Scheda Pannello Pulsanti (COD:
E3K_7A044_0)
Sezionatore Magnetico Monofase
(COD: 1SZ00037)
Sezionatore Magnetico Trifase (COD:
1SZ00036)
Cables RG178 (50 Ohm) #2 CAB0150_0
Cables RG179 (75 Ohm) #2 CAB0149_1
0
ET7000-3
ICEFET SOLID STATE FM TRANSMITTERS
Totally STAINLESS STEEL, electronic boards are Protected from Humidity and Inclement of
Tropical Weather.
All equipment undergo Rigorous Burn-In Process and quality controls.
Power sections were developed Over-Dimensioned with a conservative approach.
ICEFET Technology keeps temperature extremely low to increase the MTBF.
Fast hardware protections, further to Intelligent Proportional FoldBack of critical parameters like
VSWR and temperature.
Ventilation, power supplies, MOSFET and exciter are fully redundant to avoid any “Single Point
Failure” .
Our mission is to create the Most Reliable FM Transmitters Of The
World
MAIN CARACTERISTICS
OPERATING AT REDUCED POWER WITH ONE OR MORE BROKEN RF MODULES
OPERATING AT REDUCED POWER WITH ONE OR MORE BROKEN POWER SUPPLIES
ICE-FET:
Means Mosfet and heat sink maximum efficiency to reduce temperature, in order to obtain a higher MTBF. The result is unmatched in size and weight by any other producer
ALWAYS ON AIR: (FULLY REDUNDANT):
ALWAYS ON AIR: (FULLY REDUNDANT): The redundancy of this equipment prevents
SINGLE-POINT-FAILURES thanks to a SOFT FAILURE DESIGN and a protection system which keeps it « ON AIR» even in the most extreme working conditions.
IPC (Intelligent Power Control):
The IPC maintains constant the Output Power within 2% of the setting value, regardless of fluctuations in incoming AC line voltage, RF drive or load conditions.
IPF
The IPF allows the transmitter to stay on air into loads as poor as 3 to 1
BROAD BAND:
The transmitter keeps optimum performances of power and efficiency over the all Broad Band operation without needing of tuning what make it ideal for n+1 application
CONSTANT EFICIENCY:
The VPA and the Bias are both controlled to obtain maximum efficiency at any frequency and output power level. Keep the efficiency high means low heat, low operative cost, higher MTBF.
NO IPA:
In ELENOS transmitters, the IPA is always avoided. This choice eliminate one of the bottleneck in Redundancy frequently present on transmitters of this category.
EASY MAINTENACE:
all parts are easily accessible via the front panel(RF modules, electronic control boards) or via the rear panel (fans, combiners)
BIG COLOUR TOUCH SCREEN GRAPHIC DISPLAY:
User friendly graphic interface allow access to control and diagnosis parameters
SMS ALARMS:
All alarms and event can be send by SMS
REDUCED SIZE AND WEIGHT:
Greatly reduced size and weight: the whole transmitter is contained in a 20-unit rack with a floor plan as less as 0,31 square meter!!! (50cm width x 86cm dept )
REMOTE DEEP DIAGNOSTIC CAPABILITY:
The industrial standard Hostlink Protocol allow to safety handle huge quantity of information to perform remote deep diagnosis.
WORLS WIDE SALES & SERVICE SUPPORT:
ELENOS is the FM manufacturer with one of the biggest distribution channel of the world. Each distributor is chose mainly by the technical support customer capability.
COMPOSITION & REDUNDANCY
24 MOSFET Philips BLF278
6 Current Share combined 2.5KW
PFC switching Power Supply
12 Microprocessor Speed Controlled
Blowers
Microprocessor controlled
2 Output Harmonic Low Pass Filters
2 Exciters (in the DUAL DRIVE model )
2 x E3500 amplifiers
1 x 2 ways combiner 3600W input-
7000W output
1 x Unbalanced load 2 x 3600W inputs able to handle the maximun unbalance power without derating of the output power.
1 x TCU-Transmitter Control Unit with
LCD displau and redundant power supply.
CONFIGURATION
AAAA
20U RACK, EXAUST AIR AND CONNECTORS ON THE TOP
AAAA
EXAUST AIR AND CONNECTORS ON THE BACK
AAAA
32U RACK, EXAUST AIR AND CONNECTORS ON THE TOP
AAAA
32U RACK, EXAUST AIR AND CONNECTORS ON THE BACK
MAIN CARACTERISTICS
COMPOSED
GENERAL DATA
Transmitter Control Unit
Exciter
Dual Exciter
Amplifiers
Number of E3000 Amplifiers
Combiner
Dummy load
Mounted in 19" standard rack
Number of racks
Equipped with rack: Units
Equipped with rack: Width
Equipped with rack: Height
Equipped with rack: Depth
Output Nominal Power
Operating band
Output Low-pass Filter
Corrosion
Internal bus RS232/RS485
Points of measure
Displayed Parameters
Adjustments
Microprocessor controlled
Power supply redundancy
Blower redundancy
Number of MOSFETs
Final stage technology
Transistor type
Number of power supplies
Weight
RF Modules maximum weight
Power supply units maximum weight 6 Kg
6000 W adjustable
87.5 - 108 MHz
W.B. 87.5 MHz - 108 MHz
All mechanical parts are stainless steel
Yes
RF Sample-MPX Monitor
More than 100 parameters displayed on a LCD
From the frontal panel trough LCD
/from PC
Yes
Yes
Yes
24
ICEFET
BLF278 Philips
6
120 Kg
35 Kg
CONNETTORS
Integrated inside the Combiner
ETG300
Yes
E3000
2
COMB6/2: 2 ways 6KW combiner
Integrated inside the Combiner
Yes
1
20 U
55,8 cm
105,8 cm
93,8 cm
RF Output connector
RF Input connector
Input connectors LEFT & RIGHT
MPX Input connector
SCA Connector
Remote control connector
RS485/232 Connector
1 5/8
N
XLR female
BNC female
BNC female
DB25
DB9
RF
Overall output power stability
Output impedance
+/-0,1 dB
50 �
AUDIO
Harmonic suppression
Spurious signal suppression
Driving power final stage
Input impedance final stage
> 70 dB
> 80 dB
80 W
50 �
Gain final stage
Software V.S.W.R. intervention
16 dB
600 W threshold
Fast V.S.W.R. intervention threshold 660 W
0,1 % Asynchronous residual AM (typical values)
Synchronous residual AM (typical values)
RF Efficiency
Output nominal power
Maximum peak power
0,2 %
65% typ.
7000 W Adjustable with continuity
7500 W
L/R Audio input level
L/R level adjustment
L/R Connector type
L/R Input Impedance
MPX audio input level
MPX level adjustment
MPX Connetor type
MPX Input impedance
PILOT level adjustment
SCA/RDS Connector type
SCA/RDS Input Impedance
19KHz Output
STEREO/MPX easy changeover
AES/EBU Input option
PERFORMANCE EXCITER
Time of adjustment - frequency
Time of adjustment - power
MTBF
Programmed Maintenance
Intermodulation distortion
Frequency deviaton
Frequency steps
THD+N
Pre-emphasis
FM S/N MPX FCC
+12/-12 dBm to produce 75KHz standard deviation
Soft adjust 0,1dBm steps from front panel
Balanced XLR
Selectable 10K- 600�
+12/-12 dBm to produce 75KHz standard deviation
Soft adjust 0,1dBm steps from front panel
Unbalanced BNC
5K� selectable
Adjustable Trimmer
Unbalanced BNC
10K�
Yes
Yes
Optional (External adapter)
< 1 minute
< 1 minute
10 Years
5 Years
<0.05% Measured with two of tones
1KHz & 1.3KHz, ratio 1:1 at 100% modulation
+/- 75 KHz 0.1dB steps adjustable
10 KHz
<0.03% @ 1KHz
50/75 microseconds +/-0,1dB
82 dB 20Hz - 23KHz - 50uS - ref @
53KHz - RMS
FM S/N STEREO CCIR Weight
FM S/N STEREO CCIR Unweight
Mono frequency response
MPX frequency response
Stereo frequency response
SCA1,2,3 frequency response
Type of modulation
Stereo separation
Pilot tone frequency
Pilot tone deviation
Pilot tone frequency stability
Attenuation at 19KHz
Phase Response
Frequency stability
Time for starting up
Time for starting up
Modulation Capabilities
POWER SUPPLY
Power supply
Power consumption
Magneto-thermic curve
Current Consumption
@220VAC/single phase
Magneto-thermic capacity
@220VAC/single phase
Conductor Size @220VAC/single phase
Conductor Size @220VAC/single phase
Current Consumption
@220VAC/three phase
Magneto-thermic capacity
@220VAC/three phase
Conductor Size @220VAC/three phase
Conductor Size @220VAC/three phase
Current Consumption
@380VAC/three phase
Magneto-thermic capacity
@380VAC/three phase
Conductor Size @380VAC/three phase
72 dB Weight-ref@53KHz-Qpk
72 dB Unweight-ref@53KHz-QPk
+/-0.15 dB 30Hz - 15KHz
+/-0.1 dB 30Hz - 100KHz, -45dB at
19 KHz
+/-0.15 dB 30Hz - 15KHz
+/-1 dB 20KHz - 100KHz, -45dB at
19KHz
F3 Direct FM modulation of the RF oscillator in fundamental frequency
> 60 dB @ 1KHz
19 KHz
7,5 KHz Adjustable
+/-1 Hz
> 45 dB
0.1 degreeFrom linear phase; 53kHz to 100kHz
1 ppm from 0 to +40°C
30 sec. from OFF/ON
1 sec. from interlock close
+/-250 KHz
110,220, 380 trifase-monofase 50-
60Hz VAC
10 KVA
D
46 Amp.
63 Amp.
16 sqrt.mm
5 AWG
27 Amp.
40 Amp.
10 sqrt.mm
7 AWG
16 Amp.
25 Amp.
6 sqrt.mm
Conductor Size @380VAC/three phase
COOLING SYSTEM
Cooling flow (m3/h)
Air temperature increase between output /input
Cooling system
ENVIRONMENT
Temperature range (operating) 0 - +45 °C
Temperature range (non operating) -20 - +70 °C
Humidity range (operating)
Humidity range (non operating)
Altitude range (operating)
Altitude range (non operating)
TELECONTROL & TELEMETRY
Remote control
Remote Control at clean contacts
SNMP option
REGULATIONS CONFORMITY
High frequency radiations from the enclosure
Functionning type
Electromagnetic fields immunity
CE Mark
95% at 40 °C
90% at 65 °C
>4600 meters
>15000 meters
Yes
Yes
Under development
Below limit imposed by technical regulations.
h24 uninterrupted
Higher than specified by laws on electromagnetic fields compatibility
Conform to 1999/5/CE European
Directive
MANUFACTURING DATA
Year of the model
Spares availability guaranteed for
PRE- & POST- MAINTENANCE
Recurrence
Blower Replacement recurrence
Air blowers quantity and prices
Lithium batteris replacement recurrence
Batteries
Time to realize the preventive maintenance every 4 years
Time to realize the preventive maintenance very 8 years
Level and number of technician for maintenance
Electrical safety
Average repair time (change of an
RF module or power supply)
SET
Power supply cable
Installation manual
9 AWG
Variable from 800 to 1600 m3/h
20 °C
Forced air-cooling
2006
10 years from the date of purchase
4/8 years
4 years
6
10 years
Yes, only for alarm list storage
1 Hour
2 Hours
1 technician
EN60215 (Standard CE)
1 Hours
Yes
Yes
User manual
Maintenance manual
Yes
Yes
Tests report Yes
The equipment provided by Elenos srl covered under warranty of 24 months from the date of purchase of the product; That period is meant to be applied to the original that any subsequent buyers.
MAIN CARACTERISTICS
SPARE PARTS MAINTENACE PREVENTIVE
SPARE
PARTS
CORRE
SPARE PARTS CORRECTIVE
MAINTENACE
CTIVE
MAINTE
NACE
0
ET10000-3
ICEFET SOLID STATE FM TRANSMITTERS
Totally STAINLESS STEEL, electronic boards are Protected from Humidity and Inclement of
Tropical Weather.
All equipment undergo Rigorous Burn-In Process and quality controls.
Power sections were developed Over-Dimensioned with a conservative approach.
ICEFET Technology keeps temperature extremely low to increase the MTBF.
Fast hardware protections, further to Intelligent Proportional FoldBack of critical parameters like
VSWR and temperature.
Ventilation, power supplies, MOSFET and exciter are fully redundant to avoid any “Single Point
Failure” .
Our mission is to create the Most Reliable FM Transmitters Of The
World
MAIN CARACTERISTICS
OPERATING AT REDUCED POWER WITH ONE OR MORE BROKEN RF MODULES
OPERATING AT REDUCED POWER WITH ONE OR MORE BROKEN POWER SUPPLIES
ICE-FET:
Means Mosfet and heat sink maximum efficiency to reduce temperature, in order to obtain a higher MTBF. The result is unmatched in size and weight by any other producer
ALWAYS ON AIR: (FULLY REDUNDANT):
ALWAYS ON AIR: (FULLY REDUNDANT): The redundancy of this equipment prevents
SINGLE-POINT-FAILURES thanks to a SOFT FAILURE DESIGN and a protection system which keeps it « ON AIR» even in the most extreme working conditions.
IPC (Intelligent Power Control):
The IPC maintains constant the Output Power within 2% of the setting value, regardless of fluctuations in incoming AC line voltage, RF drive or load conditions.
IPF
The IPF allows the transmitter to stay on air into loads as poor as 3 to 1
BROAD BAND:
The transmitter keeps optimum performances of power and efficiency over the all Broad Band operation without needing of tuning what make it ideal for n+1 application
CONSTANT EFICIENCY:
The VPA and the Bias are both controlled to obtain maximum efficiency at any frequency and output power level. Keep the efficiency high means low heat, low operative cost, higher MTBF.
NO IPA:
In ELENOS transmitters, the IPA is always avoided. This choice eliminate one of the bottleneck in Redundancy frequently present on transmitters of this category.
EASY MAINTENACE:
all parts are easily accessible via the front panel(RF modules, electronic control boards) or via the rear panel (fans, combiners)
BIG COLOUR TOUCH SCREEN GRAPHIC DISPLAY:
User friendly graphic interface allow access to control and diagnosis parameters
SMS ALARMS:
All alarms and event can be send by SMS
REDUCED SIZE AND WEIGHT:
Greatly reduced size and weight: the whole transmitter is contained in a 20-unit rack with a floor plan as less as 0,31 square meter!!! (50cm width x 86cm dept )
REMOTE DEEP DIAGNOSTIC CAPABILITY:
The industrial standard Hostlink Protocol allow to safety handle huge quantity of information to perform remote deep diagnosis.
WORLS WIDE SALES & SERVICE SUPPORT:
ELENOS is the FM manufacturer with one of the biggest distribution channel of the world. Each distributor is chose mainly by the technical support customer capability.
COMPOSITION & REDUNDANCY
36 MOSFET Philips BLF278
9 Current Share combined 2.5KW
PFC switching Power Supply
18 Microprocessor Speed Controlled
Blowers
Microprocessor controlled
3 Output Harmonic Low Pass Filters
2 Exciters (in the DUAL DRIVE model )
3 x E3500 amplifiers
1 x 3 wa36 MOSFET Philips BLF278
9 Current Share combined 2.5KW
PFC switching Power Supply
18 Microprocessor Speed Controlled
Blowers
Microprocessor controlled
3 Output Harmonic Low Pass Filters
2 Exciters (in the DUAL DRIVE model )
3 x E3500 amplifiers
1 x 3 ways combiner 3600W input-
10000W output
1 x Unbalanced load 3 x 3600W inputs able to handle the maximun unbalance power without derating of
CONFIGURATION
t t
32U RACK, EXAUST AIR AND CONNECTORS ON THE TOP
32U EXAUST AIR AND CONNECTORS ON THE BACK
AAAA
COMPOSED
MAIN CARACTERISTICS
Transmitter Control Unit
Exciter
Dual Exciter
Amplifiers
Number of E3000 Amplifiers
Combiner
Dummy load
Mounted in 19" standard rack
Number of racks
Equipped with rack: Units
Equipped with rack: Width
Equipped with rack: Height
Equipped with rack: Depth
GENERAL DATA
Output Nominal Power
Operating band
Output Low-pass Filter
Corrosion
Integrated inside the Combiner
ETG300
Yes
E3000
3
COMB10/3: 3 ways combiner of
10KW
Integrated inside the Combiner
Yes
1
32 U
55,8 cm
159 cm
93,8 cm
Adjustments
6000 W adjustable
87.5 - 108 MHz
W.B. 87.5 MHz - 108 MHz
All mechanical parts are stainless steel
Yes
RF Sample-MPX Monitor
More than 100 parameters displayed on a LCD
From the frontal panel trough LCD
/from PC
Yes
Yes
Yes
36
ICEFET
BLF278 Philips
9
215 Kg
CONNETTORS
Internal bus RS232/RS485
Points of measure
Displayed Parameters
Microprocessor controlled
Power supply redundancy
Blower redundancy
Number of MOSFETs
Final stage technology
Transistor type
Number of power supplies
Weight
RF Output connector
RF Input connector
Input connectors LEFT & RIGHT
MPX Input connector
SCA Connector
Remote control connector
RS485/232 Connector
1 5/8
N
XLR female
BNC female
BNC female
DB25
DB9
RF
Overall output power stability
Output impedance
Harmonic suppression
+/-0,1 dB
50 �
> 70 dB
Spurious signal suppression
Driving power final stage
Input impedance final stage
Gain final stage
Software V.S.W.R. intervention threshold
> 80 dB
80 W
50 �
16 dB
600 W
Fast V.S.W.R. intervention threshold 660 W
Asynchronous residual AM (typical 0,1 % values)
Synchronous residual AM (typical values)
RF Efficiency
Output nominal power
Maximum peak power
0,2 %
65% typ.
10000 W Adjustable with continuity
10500 W
AUDIO
L/R Audio input level
L/R level adjustment
L/R Connector type
L/R Input Impedance
MPX audio input level
MPX level adjustment
MPX Connetor type
MPX Input impedance
PILOT level adjustment
SCA/RDS Connector type
SCA/RDS Input Impedance
19KHz Output
STEREO/MPX easy changeover
AES/EBU Input option
PERFORMANCE EXCITER
Time of adjustment - frequency
Time of adjustment - power
MTBF
Programmed Maintenance
Intermodulation distortion
Frequency deviaton
Frequency steps
THD+N
Pre-emphasis
FM S/N MPX FCC
FM S/N STEREO CCIR Weight
+12/-12 dBm to produce 75KHz standard deviation
Soft adjust 0,1dBm steps from front panel
Balanced XLR
Selectable 10K- 600�
+12/-12 dBm to produce 75KHz standard deviation
Soft adjust 0,1dBm steps from front panel
Unbalanced BNC
5K� selectable
Adjustable Trimmer
Unbalanced BNC
10K�
Yes
Yes
Optional (External adapter)
< 1 minute
< 1 minute
10 Years
5 Years
<0.05% Measured with two of tones
1KHz & 1.3KHz, ratio 1:1 at 100% modulation
+/- 75 KHz 0.1dB steps adjustable
10 KHz
<0.03% @ 1KHz
50/75 microseconds +/-0,1dB
82 dB 20Hz - 23KHz - 50uS - ref @
53KHz - RMS
72 dB Weight-ref@53KHz-Qpk
FM S/N STEREO CCIR Unweight
Mono frequency response
MPX frequency response
Stereo frequency response
SCA1,2,3 frequency response
Type of modulation
Stereo separation
Pilot tone frequency
Pilot tone deviation
Pilot tone frequency stability
Attenuation at 19KHz
Phase Response
Frequency stability
Time for starting up
Time for starting up
Modulation Capabilities
POWER SUPPLY
Power supply
Power consumption
Magneto-thermic curve
Current Consumption
@220VAC/single phase
Magneto-thermic capacity
@220VAC/single phase
Conductor Size @220VAC/single phase
Conductor Size @220VAC/single phase
Current Consumption
@220VAC/three phase
Magneto-thermic capacity
@220VAC/three phase
Conductor Size @220VAC/three phase
Conductor Size @220VAC/three phase
Current Consumption
@380VAC/three phase
Magneto-thermic capacity
@380VAC/three phase
Conductor Size @380VAC/three phase
72 dB Unweight-ref@53KHz-QPk
+/-0.15 dB 30Hz - 15KHz
+/-0.1 dB 30Hz - 100KHz, -45dB at
19 KHz
+/-0.15 dB 30Hz - 15KHz
+/-1 dB 20KHz - 100KHz, -45dB at
19KHz
F3 Direct FM modulation of the RF oscillator in fundamental frequency
> 60 dB @ 1KHz
19 KHz
7,5 KHz Adjustable
+/-1 Hz
> 45 dB
0.1 degreeFrom linear phase; 53kHz to 100kHz
1 ppm from 0 to +40°C
30 sec. from OFF/ON
1 sec. from interlock close
+/-250 KHz
220/380 V. Threephase-singlephase
50-60Hz VAC
16 KVA
D
75 Amp.
100 Amp.
25 sqrt.mm
3 AWG
43 Amp.
63 Amp.
16 sqrt.mm
5 AWG
25 Amp.
40 Amp.
10 sqrt.mm
Conductor Size @380VAC/three phase
COOLING SYSTEM
Cooling flow (m3/h)
Air temperature increase between output /input
Cooling system
ENVIRONMENT
Temperature range (operating) 0 - +45 °C
Temperature range (non operating) -20 - +70 °C
Humidity range (operating)
Humidity range (non operating)
Altitude range (operating)
Altitude range (non operating)
TELECONTROL & TELEMETRY
Remote control
Remote Control at clean contacts
SNMP option
REGULATIONS CONFORMITY
High frequency radiations from the enclosure
Functionning type
Electromagnetic fields immunity
CE Mark
95% at 40 °C
90% at 65 °C
>4600 meters
>15000 meters
Yes
Yes
Under development
Below limit imposed by technical regulations.
h24 uninterrupted
Higher than specified by laws on electromagnetic fields compatibility
Conform to 1999/5/CE European
Directive
MANUFACTURING DATA
Year of the model
Spares availability guaranteed for
PRE- & POST- MAINTENANCE
Recurrence
Blower Replacement recurrence
Air blowers quantity and prices
Lithium batteris replacement recurrence
Batteries
Time to realize the preventive maintenance every 4 years
Time to realize the preventive maintenance very 8 years
Level and number of technician for maintenance
Electrical safety
Average repair time (change of an
RF module or power supply)
SET
Power supply cable
Installation manual
7 AWG
Variable from 1200 to 2400 m3/h
20 °C
Forced air-cooling
2006
10 years from the date of purchase
4/8 years
4 years
6
10 years
Yes, only for alarm list storage
1 Hour
2 Hours
1 technician
EN60215 (Standard CE)
1 Hours
Yes
Yes
User manual
Maintenance manual
Yes
Yes
Tests report Yes
The equipment provided by Elenos srl covered under warranty of 24 months from the date of purchase of the product; That period is meant to be applied to the original that any subsequent buyers.
MAIN CARACTERISTICS
SPARE PARTS MAINTENACE PREVENTIVE
SPARE
PARTS
CORRE
SPARE PARTS CORRECTIVE
MAINTENACE
CTIVE
MAINTE
NACE
0
ET15000-3
ICEFET SOLID STATE FM TRANSMITTERS
Totally STAINLESS STEEL, electronic boards are Protected from Humidity and Inclement of
Tropical Weather.
All equipment undergo Rigorous Burn-In Process and quality controls.
Power sections were developed Over-Dimensioned with a conservative approach.
ICEFET Technology keeps temperature extremely low to increase the MTBF.
Fast hardware protections, further to Intelligent Proportional FoldBack of critical parameters like
VSWR and temperature.
Ventilation, power supplies, MOSFET and exciter are fully redundant to avoid any “Single Point
Failure” .
Our mission is to create the Most Reliable FM Transmitters Of The
World
MAIN CARACTERISTICS
OPERATING AT REDUCED POWER WITH ONE OR MORE BROKEN RF MODULES
OPERATING AT REDUCED POWER WITH ONE OR MORE BROKEN POWER SUPPLIES
ICE-FET:
Means Mosfet and heat sink maximum efficiency to reduce temperature, in order to obtain a higher MTBF. The result is unmatched in size and weight by any other producer
ALWAYS ON AIR: (FULLY REDUNDANT):
ALWAYS ON AIR: (FULLY REDUNDANT): The redundancy of this equipment prevents
SINGLE-POINT-FAILURES thanks to a SOFT FAILURE DESIGN and a protection system which keeps it « ON AIR» even in the most extreme working conditions.
IPC (Intelligent Power Control):
The IPC maintains constant the Output Power within 2% of the setting value, regardless of fluctuations in incoming AC line voltage, RF drive or load conditions.
IPF
The IPF allows the transmitter to stay on air into loads as poor as 3 to 1
BROAD BAND:
The transmitter keeps optimum performances of power and efficiency over the all Broad Band operation without needing of tuning what make it ideal for n+1 application
CONSTANT EFICIENCY:
The VPA and the Bias are both controlled to obtain maximum efficiency at any frequency and output power level. Keep the efficiency high means low heat, low operative cost, higher MTBF.
NO IPA:
In ELENOS transmitters, the IPA is always avoided. This choice eliminate one of the bottleneck in Redundancy frequently present on transmitters of this category.
EASY MAINTENACE:
all parts are easily accessible via the front panel(RF modules, electronic control boards) or via the rear panel (fans, combiners)
BIG COLOUR TOUCH SCREEN GRAPHIC DISPLAY:
User friendly graphic interface allow access to control and diagnosis parameters
SMS ALARMS:
All alarms and event can be send by SMS
REDUCED SIZE AND WEIGHT:
Greatly reduced size and weight: the whole transmitter is contained in a 20-unit rack with a floor plan as less as 0,31 square meter!!! (50cm width x 86cm dept )
REMOTE DEEP DIAGNOSTIC CAPABILITY:
The industrial standard Hostlink Protocol allow to safety handle huge quantity of information to perform remote deep diagnosis.
WORLS WIDE SALES & SERVICE SUPPORT:
ELENOS is the FM manufacturer with one of the biggest distribution channel of the world. Each distributor is chose mainly by the technical support customer capability.
COMPOSITION & REDUNDANCY
60 MOSFET Philips BLF278
15 Current Share combined 2.5KW
PFC switching Power Supply
30 Microprocessor Speed Controlled
Blowers
Microprocessor controlled
5 Output Harmonic Low Pass Filters
2 Exciters (in the DUAL DRIVE model )
5 x E3500 amplifiers
1 x 5 ways combiner 3600W input-
15000W output
1 x Unbalanced load 5 x 3600W inputs able to handle the maximun unbalance power without derating of the output power.
1 x TCU-Transmitter Control Unit with
LCD displau and redundant power supply.
CONFIGURATION
AAAA
40U RACK, EXAUST AIR AND CONNECTORS ON THE TOP
AAAA
40U EXAUST AIR AND CONNECTORS ON THE BACK
MAIN CARACTERISTICS
COMPOSED
Transmitter Control Unit
Exciter
Dual Exciter
Amplifiers
Number of E3000 Amplifiers
Combiner
GENERAL DATA
Dummy load
Mounted in 19" standard rack
Number of racks
Equipped with rack: Units
Equipped with rack: Width
Equipped with rack: Height
Equipped with rack: Depth
Output Nominal Power
Operating band
Output Low-pass Filter
Corrosion
Internal bus RS232/RS485
Points of measure
Displayed Parameters
Adjustments
Microprocessor controlled
Power supply redundancy
Blower redundancy
Number of MOSFETs
Final stage technology
Transistor type
Number of power supplies
Weight
RF Modules maximum weight
Power supply units maximum weight 6 Kg
15000 W adjustable
87.5 - 108 MHz
W.B. 87.5 MHz - 108 MHz
All mechanical parts are stainless steel
Yes
RF Sample-MPX Monitor
More than 250 parameters displayed on a LCD
From the frontal panel trough LCD
/from PC
Yes
Yes
Yes
60
ICEFET
BLF278 Philips
15
295 Kg
35 Kg
CONNETTORS
TCU with Display LCD
ETG500
Yes
E3000
5
COMB15/5: 5 ways combiner of
15KW
UNB.LOAD15/5: 15KW, 5 Ways
Yes
1
40 U
55,8 cm
197,5 cm
93,8 cm
RF Output connector
RF Input connector
Input connectors LEFT & RIGHT
MPX Input connector
SCA Connector
Remote control connector
RS485/232 Connector
3 1/8
N
XLR female
BNC female
BNC female
DB25
DB9
RF
Overall output power stability +/-0,1 dB
AUDIO
Output impedance
Harmonic suppression
Spurious signal suppression
Driving power final stage
Input impedance final stage
Gain final stage
Software V.S.W.R. intervention threshold
50 �
> 70 dB
> 80 dB
80 W
50 �
16 dB
1500 W
Fast V.S.W.R. intervention threshold 1650 W
Asynchronous residual AM (typical 0,1 % values)
Synchronous residual AM (typical values)
RF Efficiency
Output nominal power
Maximum peak power
0,2 %
65% typ.
15000 W Adjustable with continuity
16000 W
L/R Audio input level
L/R level adjustment
L/R Connector type
L/R Input Impedance
MPX audio input level
MPX level adjustment
MPX Connetor type
MPX Input impedance
PILOT level adjustment
SCA/RDS Connector type
SCA/RDS Input Impedance
19KHz Output
STEREO/MPX easy changeover
AES/EBU Input option
PERFORMANCE EXCITER
Time of adjustment - frequency
Time of adjustment - power
MTBF
Programmed Maintenance
Intermodulation distortion
Frequency deviaton
Frequency steps
THD+N
Pre-emphasis
+12/-12 dBm to produce 75KHz standard deviation
Soft adjust 0,1dBm steps from front panel
Balanced XLR
Selectable 10K- 600�
+12/-12 dBm to produce 75KHz standard deviation
Soft adjust 0,1dBm steps from front panel
Unbalanced BNC
5K� selectable
Adjustable Trimmer
Unbalanced BNC
10K�
Yes
Yes
Optional (External adapter)
< 1 minute
< 1 minute
10 Years
5 Years
<0.05% Measured with two of tones
1KHz & 1.3KHz, ratio 1:1 at 100% modulation
+/- 75 KHz 0.1dB steps adjustable
10 KHz
<0.03% @ 1KHz
50/75 microseconds +/-0,1dB
FM S/N MPX FCC
FM S/N STEREO CCIR Weight
FM S/N STEREO CCIR Unweight
Mono frequency response
MPX frequency response
Stereo frequency response
SCA1,2,3 frequency response
Type of modulation
Stereo separation
Pilot tone frequency
Pilot tone deviation
Pilot tone frequency stability
Attenuation at 19KHz
Phase Response
Frequency stability
Time for starting up
Time for starting up
Modulation Capabilities
POWER SUPPLY
Power supply
Power consumption
Magneto-thermic curve
Current Consumption
@220VAC/three phase
Magneto-thermic capacity
@220VAC/three phase
Conductor Size @220VAC/three phase
Conductor Size @220VAC/three phase
Current Consumption
@380VAC/three phase
Magneto-thermic capacity
@380VAC/three phase
Conductor Size @380VAC/three phase
Conductor Size @380VAC/three phase
COOLING SYSTEM
Cooling flow (m3/h)
Air temperature increase between output /input
Variable from 2000 to 4000 m3/h
20 °C
82 dB 20Hz - 23KHz - 50uS - ref @
53KHz - RMS
72 dB Weight-ref@53KHz-Qpk
72 dB Unweight-ref@53KHz-QPk
+/-0.15 dB 30Hz - 15KHz
+/-0.1 dB 30Hz - 100KHz, -45dB at
19 KHz
+/-0.15 dB 30Hz - 15KHz
+/-1 dB 20KHz - 100KHz, -45dB at
19KHz
F3 Direct FM modulation of the RF oscillator in fundamental frequency
> 60 dB @ 1KHz
19 KHz
7,5 KHz Adjustable
+/-1 Hz
> 45 dB
0.1 degreeFrom linear phase; 53kHz to 100kHz
1 ppm from 0 to +40°C
30 sec. from OFF/ON
1 sec. from interlock close
+/-250 KHz
110,220, 380 trifase-monofase 50-
60Hz VAC
25 KVA
D
68 Amp.
100 Amp.
25 sqrt.mm
3 AWG
40 Amp.
63 Amp.
16 sqrt.mm
5 AWG
ENVIRONMENT
Cooling system
Humidity range (operating)
Humidity range (non operating)
Altitude range (operating)
Altitude range (non operating)
TELECONTROL & TELEMETRY
Remote control
Remote Control at clean contacts
SNMP option
REGULATIONS CONFORMITY
High frequency radiations from the enclosure
Functionning type
Electromagnetic fields immunity
CE Mark
Forced air-cooling
Temperature range (operating) 0 - +45 °C
Temperature range (non operating) -20 - +70 °C
95% at 40 °C
90% at 65 °C
>4600 meters
>15000 meters
Yes
Yes
Under development
Below limit imposed by technical regulations.
h24 uninterrupted
Higher than specified by laws on electromagnetic fields compatibility
Conform to 1999/5/CE European
Directive
MANUFACTURING DATA
Year of the model
Spares availability guaranteed for
PRE- & POST- MAINTENANCE
Recurrence
Blower Replacement recurrence
Air blowers quantity and prices
Lithium batteris replacement recurrence
Batteries
Time to realize the preventive maintenance every 4 years
Time to realize the preventive maintenance very 8 years
Level and number of technician for maintenance
Electrical safety
Average repair time (change of an
RF module or power supply)
2005
10 years from the date of purchase
4/8 years
4 years
6
10 years
Yes, only for alarm list storage
1 Hour
2 Hours
1 technician
EN60215 (Standard CE)
1 Hours
SET
Power supply cable
Installation manual
User manual
Maintenance manual
Yes
Yes
Yes
Yes
Tests report Yes
The equipment provided by Elenos srl covered under warranty of 24 months from the date of purchase of the product; That period is meant to be applied to the original that any subsequent buyers.
MAIN CARACTERISTICS
SPARE PARTS MAINTENACE PREVENTIVE
SPARE
PARTS
CORRE
SPARE PARTS CORRECTIVE
MAINTENACE
CTIVE
MAINTE
NACE
0
ET31000-3
ICEFET SOLID STATE FM TRANSMITTERS
Totally STAINLESS STEEL, electronic boards are Protected from Humidity and Inclement of
Tropical Weather.
All equipment undergo Rigorous Burn-In Process and quality controls.
Power sections were developed Over-Dimensioned with a conservative approach.
ICEFET Technology keeps temperature extremely low to increase the MTBF.
Fast hardware protections, further to Intelligent Proportional FoldBack of critical parameters like
VSWR and temperature.
Ventilation, power supplies, MOSFET and exciter are fully redundant to avoid any “Single Point
Failure” .
Our mission is to create the Most Reliable FM Transmitters Of The
World
MAIN CARACTERISTICS
OPERATING AT REDUCED POWER WITH ONE OR MORE BROKEN RF MODULES
OPERATING AT REDUCED POWER WITH ONE OR MORE BROKEN POWER SUPPLIES
ICE-FET:
Means Mosfet and heat sink maximum efficiency to reduce temperature, in order to obtain a higher MTBF. The result is unmatched in size and weight by any other producer
ALWAYS ON AIR: (FULLY REDUNDANT):
ALWAYS ON AIR: (FULLY REDUNDANT): The redundancy of this equipment prevents
SINGLE-POINT-FAILURES thanks to a SOFT FAILURE DESIGN and a protection system which keeps it « ON AIR» even in the most extreme working conditions.
IPC (Intelligent Power Control):
The IPC maintains constant the Output Power within 2% of the setting value, regardless of fluctuations in incoming AC line voltage, RF drive or load conditions.
IPF
The IPF allows the transmitter to stay on air into loads as poor as 3 to 1
BROAD BAND:
The transmitter keeps optimum performances of power and efficiency over the all Broad Band operation without needing of tuning what make it ideal for n+1 application
CONSTANT EFICIENCY:
The VPA and the Bias are both controlled to obtain maximum efficiency at any frequency and output power level. Keep the efficiency high means low heat, low operative cost, higher MTBF.
NO IPA:
In ELENOS transmitters, the IPA is always avoided. This choice eliminate one of the bottleneck in Redundancy frequently present on transmitters of this category.
EASY MAINTENACE:
all parts are easily accessible via the front panel(RF modules, electronic control boards) or via the rear panel (fans, combiners)
BIG COLOUR TOUCH SCREEN GRAPHIC DISPLAY:
User friendly graphic interface allow access to control and diagnosis parameters
SMS ALARMS:
All alarms and event can be send by SMS
REDUCED SIZE AND WEIGHT:
Greatly reduced size and weight: the whole transmitter is contained in a 20-unit rack with a floor plan as less as 0,31 square meter!!! (50cm width x 86cm dept )
REMOTE DEEP DIAGNOSTIC CAPABILITY:
The industrial standard Hostlink Protocol allow to safety handle huge quantity of information to perform remote deep diagnosis.
WORLS WIDE SALES & SERVICE SUPPORT:
ELENOS is the FM manufacturer with one of the biggest distribution channel of the world. Each distributor is chose mainly by the technical support customer capability.
COMPOSITION & REDUNDANCY
120 MOSFET Philips BLF278
30 Current Share combined 2.5KW
PFC switching Power Supply
60 Microprocessor Speed Controlled
Blowers
Microprocessor controlled
10 Output Harmonic Low Pass Filters
2 Exciters (in the DUAL DRIVE model)
10 x E3500 amplifiers
2 x 5 ways combiner 3600W input-
15000W output
2 x Unbalanced load 5 x 3600W inputs able to handle the maximun unbalance power without derating of the output power.
2 x TCU-Transmitter Control Unit with
LCD displau and redundant power supply.
1 x SCU-System Control Unit with
Color LCD with Touch Screen and redundant power supply.
CONFIGURATION
40U RACK, EXAUST AIR AND CONNECTORS ON THE TOP
AAAA
AAAA
40U EXAUST AIR AND CONNECTORS ON THE BACK
MAIN CARACTERISTICS
COMPOSED
GENERAL DATA
Dummy load
Mounted in 19" standard rack
Number of racks
Equipped with rack: Units
Equipped with rack: Width
Equipped with rack: Height
Equipped with rack: Depth
CONNETTORS
System Control units
Output Hybrid Combiner
Hybrid Combiner Dummy Load
Input Splitter
Transmitter Control Unit
Exciter
Dual Exciter
Amplifiers
Number of E3000 Amplifiers
Combiner
SCU with Graphic Display and Touch-
Screen
31KW
Bird 10KW
1 input 1KW 2 output 500W
TCU with Display LCD
ETG1000
Yes
E3000
10
COMB15/5: 5 ways combiner of
15KW
Output Nominal Power
Operating band
Output Low-pass Filter
Corrosion
Internal bus RS232/RS485
Points of measure
Displayed Parameters
Adjustments
Microprocessor controlled
Power supply redundancy
Blower redundancy
Number of MOSFETs
Final stage technology
Transistor type
Number of power supplies
Weight
RF Modules maximum weight
Power supply units maximum weight 6 Kg
31000 W adjustable
87.5 - 108 MHz
W.B. 87.5 MHz - 108 MHz
All mechanical parts are stainless steel
Yes
RF Sample-MPX Monitor
More than 250 parameters displayed on a LCD
From the frontal panel trough LCD
/from PC
Yes
Yes
Yes
60
ICEFET
BLF278 Philips
30
600 Kg
35 Kg
RF Output connector
RF Input connector
Input connectors LEFT & RIGHT
MPX Input connector
UNB.LOAD15/5: 15KW, 5 Ways
Yes
2
40+40 U
Tot. 120 cm
197,5 cm
93,8 cm
3 1/8
N
XLR female
BNC female
RF
SCA Connector
Remote control connector
RS485/232 Connector
BNC female
DB25
DB9
Overall output power stability
Output impedance
Harmonic suppression
Spurious signal suppression
Driving power final stage
Input impedance final stage
Gain final stage
Software V.S.W.R. intervention
+/-0,1 dB
50 �
> 70 dB
> 80 dB
80 W
50 �
16 dB
3000 W threshold
Fast V.S.W.R. intervention threshold 3300 W
Asynchronous residual AM (typical values)
Synchronous residual AM (typical values)
0,1 %
0,2 %
RF Efficiency
Output nominal power
Maximum peak power
65% typ.
31000 W Adjustable with continuity
31000 W
AUDIO
L/R Audio input level
L/R level adjustment
L/R Connector type
L/R Input Impedance
MPX audio input level
MPX level adjustment
MPX Connetor type
MPX Input impedance
PILOT level adjustment
SCA/RDS Connector type
SCA/RDS Input Impedance
19KHz Output
STEREO/MPX easy changeover
AES/EBU Input option
PERFORMANCE EXCITER
Time of adjustment - frequency
Time of adjustment - power
MTBF
Programmed Maintenance
Intermodulation distortion
+12/-12 dBm to produce 75KHz standard deviation
Soft adjust 0,1dBm steps from front panel
Balanced XLR
Selectable 10K- 600�
+12/-12 dBm to produce 75KHz standard deviation
Soft adjust 0,1dBm steps from front panel
Unbalanced BNC
5K� selectable
Adjustable Trimmer
Unbalanced BNC
10K�
Yes
Yes
Optional (External adapter)
< 1 minute
< 1 minute
10 Years
5 Years
<0.05% Measured with two of tones
1KHz & 1.3KHz, ratio 1:1 at 100% modulation
Frequency deviaton
Frequency steps
THD+N
Pre-emphasis
FM S/N MPX FCC
FM S/N STEREO CCIR Weight
FM S/N STEREO CCIR Unweight
Mono frequency response
MPX frequency response
Stereo frequency response
SCA1,2,3 frequency response
Type of modulation
Stereo separation
Pilot tone frequency
Pilot tone deviation
Pilot tone frequency stability
Attenuation at 19KHz
Phase Response
Frequency stability
Time for starting up
Time for starting up
Modulation Capabilities
POWER SUPPLY
Power supply
Power consumption
Magneto-thermic curve
Current Consumption
@220VAC/three phase
Magneto-thermic capacity
@220VAC/three phase
Conductor Size @220VAC/three phase
Conductor Size @220VAC/three phase
Current Consumption
@380VAC/three phase
Magneto-thermic capacity
@380VAC/three phase
Conductor Size @380VAC/three phase
Conductor Size @380VAC/three phase
+/- 75 KHz 0.1dB steps adjustable
10 KHz
<0.03% @ 1KHz
50/75 microseconds +/-0,1dB
82 dB 20Hz - 23KHz - 50uS - ref @
53KHz - RMS
72 dB Weight-ref@53KHz-Qpk
72 dB Unweight-ref@53KHz-QPk
+/-0.15 dB 30Hz - 15KHz
+/-0.1 dB 30Hz - 100KHz, -45dB at
19 KHz
+/-0.15 dB 30Hz - 15KHz
+/-1 dB 20KHz - 100KHz, -45dB at
19KHz
F3 Direct FM modulation of the RF oscillator in fundamental frequency
> 60 dB @ 1KHz
19 KHz
7,5 KHz Adjustable
+/-1 Hz
> 45 dB
0.1 degreeFrom linear phase; 53kHz to 100kHz
1 ppm from 0 to +40°C
30 sec. from OFF/ON
1 sec. from interlock close
+/-250 KHz
110,220, 380 trifase-monofase 50-
60Hz VAC
51 KVA
D
2x68 Amp.
2x100 Amp.
2x25 sqrt.mm
2x3 AWG
2x40 Amp.
2x63 Amp.
2x16 sqrt.mm
2x5 AWG
COOLING SYSTEM
Cooling flow (m3/h)
Air temperature increase between output /input
Cooling system
ENVIRONMENT
Variable from 4000 to 8000 m3/h
20 °C
Forced air-cooling
Temperature range (operating) 0 - +45 °C
Temperature range (non operating) -20 - +70 °C
Humidity range (operating)
Humidity range (non operating)
95% at 40 °C
90% at 65 °C
>4600 meters
>15000 meters
Altitude range (operating)
Altitude range (non operating)
TELECONTROL & TELEMETRY
Remote control
Remote Control at clean contacts
SNMP option
REGULATIONS CONFORMITY
High frequency radiations from the enclosure
Functionning type
Electromagnetic fields immunity
CE Mark
Yes
Yes
Under development
Below limit imposed by technical regulations.
h24 uninterrupted
Higher than specified by laws on electromagnetic fields compatibility
Conform to 1999/5/CE European
Directive
MANUFACTURING DATA
Year of the model
Spares availability guaranteed for
PRE- & POST- MAINTENANCE
Recurrence
Blower Replacement recurrence
Air blowers quantity and prices
Lithium batteris replacement recurrence
Batteries
Time to realize the preventive maintenance every 4 years
Time to realize the preventive maintenance very 8 years
Level and number of technician for maintenance
Electrical safety
Average repair time (change of an
RF module or power supply)
SET
Power supply cable
Installation manual
User manual
Maintenance manual
2005
10 years from the date of purchase
4/8 years
4 years
6
10 years
Yes, only for alarm list storage
1 Hour
2 Hours
1 technician
EN60215 (Standard CE)
1 Hours
Yes
Yes
Yes
Yes
Tests report Yes
The equipment provided by Elenos srl covered under warranty of 24 months from the date of purchase of the product; That period is meant to be applied to the original that any subsequent buyers.
MAIN CARACTERISTICS
SPARE PARTS MAINTENACE PREVENTIVE
SPARE
PARTS
CORRE
SPARE PARTS CORRECTIVE
MAINTENACE
CTIVE
MAINTE
NACE
0
ETG101
100W FM Transmitter
xx
BACK VIEW
TOP VIEW
aaaaaa
MAIN DISPLAY
COMPOSED
GENERAL DATA
Mounted in 19" standard rack
Operating band
Output Low-pass Filter
Corrosion
Internal bus RS232/RS485
Points of measure
Displayed Parameters
Adjustments
Microprocessor controlled
Power supply redundancy
Blower redundancy
Final stage technology
Transistor type
Compact
CONNETTORS
RF Output connector
Input connectors LEFT & RIGHT
MPX Input connector
SCA Connector
Remote control connector
RS485/232 Connector
RF
Automatic gain control
Overall output power stability
Harmonic suppression
Spurious signal suppression
Output nominal power
Maximum peak power
AUDIO
L/R Audio input level
L/R level adjustment
L/R Connector type
L/R Input Impedance
MPX audio input level
MPX level adjustment
MPX Connetor type
MPX Input impedance
PILOT level adjustment
SCA/RDS Connector type
SCA/RDS Input Impedance
Yes
87.5 - 108 MHz
W.B. 87.5 MHz - 108 MHz
All mechanical parts are stainless steel
Yes
RF Sample-MPX Monitor
More than 50 parameters displayed on a LCD
From the frontal panel trough LCD
/from PC
Yes
Yes
Yes
MOSFET
BLF177 Philips
Yes
N
XLR female
BNC female
BNC female
DB25
DB9
Stabilizes the output power value onthe set value
+/-0,1 dB
> 70 dB
> 80 dB
100 W Adjustable with continuity
140 W
+12/-12 dBm to produce 75KHz standard deviation
Soft adjust 0,1dBm steps from front panel
Balanced XLR
10K- 600 selectable
+12/-12 dBm to produce 75KHz standard deviation
Soft adjust 0,1dBm steps from front panel
Unbalanced BNC
10 K�- 600 � selectable
Trimmer adjustable
BNC
10 K��
19KHz Output
STEREO/MPX easy changeover
AES/EBU Input option
PERFORMANCE EXCITER
Intermodulation distortion
Frequency deviaton
THD+N
Pre-emphasis
Mono frequency response
MPX frequency response
Stereo frequency response
SCA1,2,3 frequency response
Type of modulation
POWER SUPPLY
Pilot tone frequency stability
Power supply
Power consumption
COOLING SYSTEM
Cooling system
ENVIRONMENT
Temperature range (operating)
Temperature range (non operating)
Humidity range (operating)
Humidity range (non operating)
Altitude range (operating)
Altitude range (non operating)
TELECONTROL & TELEMETRY
Remote control
Remote Control at clean contacts
SNMP option
High frequency radiations from the enclosure
Functionning type
Electromagnetic fields immunity
CE Mark
MANUFACTURING DATA
Year of the model
Spares availability guaranteed for
PRE- & POST- MAINTENANCE
Recurrence
Blower Replacement recurrence
Yes
Yes
Optional (External adapter)
<0.05% Measured with two of tones
1KHz & 1.3KHz, ratio 1:1 at 100% modulation
+/- 75 KHz 0.1dB steps adjustable
<0.03% @ 1KHz
50/75 microseconds +/-0,1dB
+/-0.15 dB 30Hz - 15KHz
+/-0.1 dB 30Hz - 100KHz, -45dB at 19
KHz
+/-0.15 dB 30Hz - 15KHz
+/-1 dB 20KHz - 100KHz, -45dB at
19KHz
F3 Direct FM modulation of the RF oscillator in fundamental frequency
+/-1 Hz
110-240 VAC
180W typical to the maximum output power KVA
Foced air-cooling
0 - +45 °C
-20 - +50 °C
95% a 40 °C
90% a 65 °C
>4600 meters
>15000 meters
Sì
Sì
Below limit imposed by technical regulations.
h24 uninterrupted
Higher than specified by laws on electromagnetic fields compatibility
Conform to 1999/5/CE European
Directive
2005
10 years from the date of purchase
4/8 years
4 years
Air blowers quantity and prices
Lithium batteris replacement recurrence
Batteries
Time to realize the preventive maintenance every 4 years
Time to realize the preventive maintenance very 8 years
Level and number of technician for maintenance
Electrical safety
Average repair time (change of an RF module or power supply)
2 x 36 +
2 x 24,6
10 years
Yes
1 ohur
2 ohur
1 technician
EN60215(Standard CE)
1 Hour
SET
Power supply cable
Installation manual
User manual
Maintenance manual
Tests report
Yes
Yes
Yes
Yes
Yes
PRICES
Cost for 3 years warranty extention 2% price list
The equipment provided by Elenos srl covered under warranty of 24 months from the date of purchase of the product; That period is meant to be applied to the original that any subsequent buyers.
SPARE PARTS MAINTENACE PREVENTIVE
Power Supply #1 (COD: TG1
2A111_0)
Fuse Kit
RF Fan (COD: 1VENT005)
Fuse Kit 101
SPARE PARTS CORRECTIVE MAINTENACE
Mosfet #1 (COD: 2QRF00006
(BLF177))
CPU
Display (COD: ETG100DS1)
(vedere scheda eccitatore) front panel (COD: 9MOD2596_2)
Output armonic filter L.P. FILTER
(COD: TG13A111_0 (con testina))
Temperature sensor board #1 (COD:
E2K 7A000_1)
Exiter board (monoscheda)
Driver Board (COD: TG1 0A111_1)
TG5 3A141_1
Scheda Pannello Pulsanti
Scheda Finale
TG5 4A141_0
TG1 1A111_0
Trasformatore Alimentazione Servizi 2XRFT016
ETG300
300W FM Transmitter
xx
BACK VIEW
TOP VIEW
aaaaaa
MAIN DISPLAY
COMPOSED
GENERAL DATA
Mounted in 19" standard rack
Operating band
Output Low-pass Filter
Corrosion
Internal bus RS232/RS485
Points of measure
Displayed Parameters
Adjustments
Microprocessor controlled
Final stage technology
Transistor type
Compact
CONNETTORS
RF Output connector
Input connectors LEFT & RIGHT
MPX Input connector
SCA Connector
Remote control connector
RS485/232 Connector
RF
AUDIO
Automatic gain control
Overall output power stability
Harmonic suppression
Spurious signal suppression
RF Efficiency
L/R Audio input level
L/R level adjustment
L/R Connector type
L/R Input Impedance
MPX audio input level
MPX level adjustment
MPX Connetor type
MPX Input impedance
PILOT level adjustment
SCA/RDS Connector type
SCA/RDS Input Impedance
19KHz Output
Yes
87.5 - 108 MHz
W.B. 87.5 MHz - 108 MHz
All mechanical parts are stainless steel
Yes
RF Sample-MPX Monitor
More than 50 parameters displayed on a LCD
From the frontal panel trough LCD
/from PC
Yes
MOSFET
BLF278 Philips
Yes
N
XLR female
BNC female
BNC female
DB25
DB9
Stabilizes the output power value onthe set value
+/-0,1 dB
> 70 dB
> 80 dB
43
+12/-12 dBm to produce 75KHz standard deviation
Soft adjust 0,1dBm steps from front panel
Balanced XLR
10K- 600 selectable
+12/-12 dBm to produce 75KHz standard deviation
Soft adjust 0,1dBm steps from front panel
Unbalanced BNC
10 K�- 600 � selectable
Trimmer adjustable
BNC
10 K��
Yes
STEREO/MPX easy changeover
AES/EBU Input option
PERFORMANCE EXCITER
Intermodulation distortion
Frequency deviaton
THD+N
Pre-emphasis
Mono frequency response
MPX frequency response
Stereo frequency response
SCA1,2,3 frequency response
Type of modulation
CE Mark
Year of the model
Spares availability guaranteed for
Recurrence
Blower Replacement recurrence
Air blowers quantity and prices
Yes
Optional (External adapter)
<0.05% Measured with two of tones
1KHz & 1.3KHz, ratio 1:1 at 100% modulation
+/- 75 KHz 0.1dB steps adjustable
<0.03% @ 1KHz
50/75 microseconds +/-0,1dB
+/-0.15 dB 30Hz - 15KHz
+/-0.1 dB 30Hz - 100KHz, -45dB at
19 KHz
+/-0.15 dB 30Hz - 15KHz
+/-1 dB 20KHz - 100KHz, -45dB at
19KHz
F3 Direct FM modulation of the RF oscillator in fundamental frequency
+/-1 Hz Pilot tone frequency stability
POWER SUPPLY
COOLING SYSTEM
Cooling system
ENVIRONMENT
Power supply
Power consumption
110-240 VAC
500 KVA
Foced air-cooling
Temperature range (operating) 0 - +45 °C
Temperature range (non operating) -20 - +50 °C
Humidity range (operating)
Humidity range (non operating)
Altitude range (operating)
Altitude range (non operating)
High frequency radiations from the enclosure
Functionning type
Electromagnetic fields immunity
95% a 40 °C
90% a 65 °C
>4600 meters
>15000 meters
Below limit imposed by technical regulations.
h24 uninterrupted
Higher than specified by laws on electromagnetic fields compatibility
Conform to 1999/5/CE European
Directive
2005
10 years from the date of purchase
4/8 years
4 years
2 x 36 +
2 x 24,6
10 years Lithium batteris replacement recurrence
Batteries
Time to realize the preventive maintenance every 4 years
Yes
1 ohur
Time to realize the preventive maintenance very 8 years
Level and number of technician for maintenance
Electrical safety
Average repair time (change of an
RF module or power supply)
2 ohur
1 technician
EN60215(Standard CE)
1 Hour
SET
Power supply cable
Installation manual
User manual
Maintenance manual
Yes
Yes
Yes
Yes
Tests report Yes
The equipment provided by Elenos srl covered under warranty of 24 months from the date of purchase of the product; That period is meant to be applied to the original that any subsequent buyers.
SPARE PARTS MAINTENACE PREVENTIVE
Fuse Kit
RF Fan
SPARE PARTS CORRECTIVE MAINTENACE
CPU
Display front panel
Temperature sensor board #1
Exiter board (monoscheda)
Fuse Kit 300
1VENT002
(vedere scheda eccitatore)
ETG100DS1
9MOD2596_2
E2K 7A000_1
TG5 3A141_1
ETG500
500W FM Transmitter
xx
BACK VIEW
TOP VIEW
aaaaaa
MAIN DISPLAY
COMPOSED
GENERAL DATA
Mounted in 19" standard rack
CONNETTORS
RF
AUDIO
Operating band
Output Low-pass Filter
Corrosion
Internal bus RS232/RS485
Points of measure
Displayed Parameters
Adjustments
Microprocessor controlled
Final stage technology
Transistor type
RF Modules maximum weight
Number of cooling fans or wind turbines on the amplifiers
Compact
Yes
87.5 - 108 MHz
W.B. 87.5 MHz - 108 MHz
All mechanical parts are stainless steel
Yes
RF Sample-MPX Monitor
More than 50 parameters displayed on a LCD
From the frontal panel trough LCD
/from PC
Yes
MOSFET
BLF278 Philips
2
Kg
RF Output connector
Input connectors LEFT & RIGHT
MPX Input connector
SCA Connector
Remote control connector
RS485/232 Connector
Yes
N
XLR female
BNC female
BNC female
DB25
DB9
Automatic gain control
Overall output power stability
Harmonic suppression
Spurious signal suppression
Software V.S.W.R. intervention
Stabilizes the output power value onthe set value
+/-0,1 dB
> 70 dB
> 80 dB
50 W threshold
Fast V.S.W.R. intervention threshold 50 W
RF Efficiency
Maximum peak power
52
600 W
L/R Audio input level
L/R level adjustment
L/R Connector type
L/R Input Impedance
MPX audio input level
+12/-12 dBm to produce 75KHz standard deviation
Soft adjust 0,1dBm steps from front panel
Balanced XLR
10K- 600 selectable
+12/-12 dBm to produce 75KHz standard deviation
MPX level adjustment
MPX Connetor type
MPX Input impedance
PILOT level adjustment
SCA/RDS Connector type
SCA/RDS Input Impedance
19KHz Output
STEREO/MPX easy changeover
AES/EBU Input option
PERFORMANCE EXCITER
Intermodulation distortion
Soft adjust 0,1dBm steps from front panel
Unbalanced BNC
10 K�- 600 � selectable
Trimmer adjustable
BNC
10 K��
Yes
Yes
Optional (External adapter)
Frequency deviaton
THD+N
Pre-emphasis
Mono frequency response
MPX frequency response
Stereo frequency response
SCA1,2,3 frequency response
Type of modulation
<0.05% Measured with two of tones
1KHz & 1.3KHz, ratio 1:1 at 100% modulation
+/- 75 KHz 0.1dB steps adjustable
<0.03% @ 1KHz
50/75 microseconds +/-0,1dB
+/-0.15 dB 30Hz - 15KHz
+/-0.1 dB 30Hz - 100KHz, -45dB at
19 KHz
+/-0.15 dB 30Hz - 15KHz
+/-1 dB 20KHz - 100KHz, -45dB at
19KHz
F3 Direct FM modulation of the RF oscillator in fundamental frequency
+/-1 Hz Pilot tone frequency stability
POWER SUPPLY
COOLING SYSTEM
Cooling system
ENVIRONMENT
Power supply
Power consumption
110-240 VAC
900 KVA
Foced air-cooling
Temperature range (operating) 0 - +45 °C
Temperature range (non operating) -20 - +50 °C
Humidity range (operating)
Humidity range (non operating)
Altitude range (operating)
Altitude range (non operating)
Remote control
Remote Control at clean contacts
SNMP option
High frequency radiations from the enclosure
Functionning type
Electromagnetic fields immunity
CE Mark
95% a 40 °C
90% a 65 °C
>4600 meters
>15000 meters
Yes
Yes
Under develop
Below limit imposed by technical regulations.
h24 uninterrupted
Higher than specified by laws on electromagnetic fields compatibility
Conform to 1999/5/CE European
Directive
Year of the model
Spares availability guaranteed for
Recurrence
Blower Replacement recurrence
Lithium batteris replacement recurrence
Batteries
Time to realize the preventive maintenance every 4 years
Time to realize the preventive maintenance very 8 years
Level and number of technician for maintenance
Electrical safety
Average repair time (change of an
RF module or power supply)
2005
10 years from the date of purchase
4/8 years
4 years
No
No
1 ohur
2 ohur
1 technician
EN60215(Standard CE)
1 Hour
SET
Power supply cable
Installation manual
User manual
Maintenance manual
Tests report
Yes
Yes
Yes
Yes
Yes
PRICES
Cost for 3 years warranty extention 2% price list
The equipment provided by Elenos srl covered under warranty of 24 months from the date of purchase of the product; That period is meant to be applied to the original that any subsequent buyers.
SPARE PARTS MAINTENACE PREVENTIVE
Power Supply #1 (COD:
ETGALIMDR)
Fuse Kit
RF Fan (COD: 1VENT002)
Fuse Kit 500
SPARE PARTS CORRECTIVE MAINTENACE
RF Amplifier Module Sx.
RF Amplifier Module Dx.
Complete RF Amplifier board with
Mosfets #1
Complete RF Amplifier board with
Mosfets #2
Mosfet #1 (COD: 2QRF0012
(BLF278))
TG501141_2
TG500141_2
TG5 0A141_2 (R)
TG5 0B141_2 (L)
CPU
Display (COD: ETG100DS1)
(see exciter board)
Absorber Resistors #1 (COD:
2RAF1007)
front panel (COD: 9MOD2596_2)
Output armonic filter L.P. FILTER
Temperature sensor board #1 (COD:
E2K 7A000_1)
ETG50A 101_1
Exiter board (monoscheda)
Driver Board
Scheda Splitter #1
Scheda Pannello Pulsanti
TG5 3A141_1
TG5 2A141_1
ETGSPL01
TG5 4A141_0
Scheda Regolatore TG1K1A151_1
Trasformatore Alimentazione Servizi E1KDRAUX
Cables RG302 (75 Ohm) #1 CSF0027
ETG1000
Trasmettitore FM 1000W
xx
BACK VIEW
TOP VIEW
aaaaaa
MAIN DISPLAY
GENERAL DATA
Number of E3000 Amplifiers
Mounted in 19" standard rack
Output Nominal Power
Operating band
Output Low-pass Filter
Corrosion
Internal bus RS232/RS485
Points of measure
Displayed Parameters
Adjustments
CONNETTORS
RF
Microprocessor controlled
Power supply redundancy
Blower redundancy
Final stage technology
Transistor type
Dimensions: Width
Weight
RF Modules maximum weight
Number of cooling fans or wind turbines on the amplifiers
Number of cooling fans or wind turbines on the exciter
Compact
RF Output connector
Input connectors LEFT & RIGHT
MPX Input connector
SCA Connector
Remote control connector
RS485/232 Connector
Automatic gain control
Overall output power stability
Harmonic suppression
Spurious signal suppression
AUDIO
L/R Audio input level
L/R level adjustment
L/R Connector type
L/R Input Impedance
4
Yes
1000 W adjustable
87.5 - 108 MHz
W.B. 87.5 MHz - 108 MHz
All mechanical parts are stainless steel
Yes
RF Sample-MPX Monitor
More than 50 parameters displayed on a LCD
From the frontal panel trough LCD
/from PC
Yes
Yes
Yes
MOSFET
BLF278 Philips
46 cm
22 Kg
2
Kg
2
Yes
7/16''
XLR female
BNC female
BNC female
DB25
DB9
Stabilizes the output power value onthe set value
+/-0,1 dB
> 70 dB
> 80 dB
+12/-12 dBm to produce 75KHz standard deviation
Soft adjust 0,1dBm steps from front panel
Balanced XLR
10K- 600 selectable
MPX audio input level
MPX level adjustment
MPX Connetor type
MPX Input impedance
PILOT level adjustment
SCA/RDS Connector type
SCA/RDS Input Impedance
19KHz Output
STEREO/MPX easy changeover
AES/EBU Input option
PERFORMANCE EXCITER
Intermodulation distortion
+12/-12 dBm to produce 75KHz standard deviation
Soft adjust 0,1dBm steps from front panel
Unbalanced BNC
10 K�- 600 � selectable
Trimmer adjustable
BNC
10 K��
Yes
Yes
Optional (External adapter)
Frequency deviaton
THD+N
Pre-emphasis
Mono frequency response
MPX frequency response
Stereo frequency response
SCA1,2,3 frequency response
Type of modulation
Pilot tone frequency stability
<0.05% Measured with two of tones
1KHz & 1.3KHz, ratio 1:1 at 100% modulation
+/- 75 KHz 0.1dB steps adjustable
<0.03% @ 1KHz
50/75 microseconds +/-0,1dB
+/-0.15 dB 30Hz - 15KHz
+/-0.1 dB 30Hz - 100KHz, -45dB at
19 KHz
+/-0.15 dB 30Hz - 15KHz
+/-1 dB 20KHz - 100KHz, -45dB at
19KHz
F3 Direct FM modulation of the RF oscillator in fundamental frequency
+/-1 Hz
POWER SUPPLY
Power supply
Power consumption
Altitude range (operating)
Altitude range (non operating)
Remote control
Remote Control at clean contacts
SNMP option
High frequency radiations from the enclosure
Functionning type
110-240 VAC
1600W typical to the maximum output power KVA
COOLING SYSTEM
Cooling system
ENVIRONMENT
Foced air-cooling
Temperature range (operating) 0 - +45 °C
Temperature range (non operating) -20 - +50 °C
Humidity range (operating)
Humidity range (non operating)
95% a 40 °C
90% a 65 °C
>4600 meters
>15000 meters
Yes
Yes
Under develop
Below limit imposed by technical regulations.
h24 uninterrupted
Electromagnetic fields immunity
CE Mark
Year of the model
Spares availability guaranteed for
Recurrence
Blower Replacement recurrence
Air blowers quantity and prices
Higher than specified by laws on electromagnetic fields compatibility
Conform to 1999/5/CE European
Directive
2005
10 years from the date of purchase
4/8 years
4 years
2 x 36 +
2 x 24,6
10 years Lithium batteris replacement recurrence
Batteries
Time to realize the preventive maintenance every 4 years
Time to realize the preventive maintenance very 8 years
Level and number of technician for maintenance
Electrical safety
Average repair time (change of an
RF module or power supply)
Yes
1 ohur
2 ohur
1 technician
EN60215(Standard CE)
1 Hour
SET
Power supply cable
Installation manual
User manual
Maintenance manual
Tests report
Yes
Yes
Yes
Yes
Yes
PRICES
Cost for 3 years warranty extention 2% price list
The equipment provided by Elenos srl covered under warranty of 24 months from the date of purchase of the product; That period is meant to be applied to the original that any subsequent buyers.
SPARE PARTS MAINTENACE PREVENTIVE
Power Supply #1 (COD:
ETGALIMPFC)
Power Supply #2 (COD:
ETGALIMDR)
Fuse Kit
RF Fan (COD: 1VENT002)
Fuse Kit 1000
Output Fan
Power Supply Fan (COD:
1VENT020)
Aux Fan
SPARE PARTS CORRECTIVE MAINTENACE
RF Amplifier Module Sx.
RF Amplifier Module Dx.
Complete RF Amplifier board with
Mosfets #1
Complete RF Amplifier board with
Mosfets #2
Mosfet #1 (COD: 2QRF0012
(BLF278))
TG501141_2
TG500141_2
TG5 0A141_2 (R)
TG5 0B141_2 (L)
Mosfet #2 (COD: 2QRF0016
(BLF245))
CPU
Display (COD: ETG100DS1)
(see exciter board)
Absorber Resistors #1 (COD:
2RAF1007) front panel (COD: 9MOD2596_2)
Output armonic filter L.P. FILTER
Temperature sensor board #1 (COD:
E2K 7A000_1)
TG1K4A151_0
Exiter board (monoscheda) (COD:
TG1K AA151_1)
Driver Board TG030A 101_1
Scheda Testina di Lettura (COD:
TG1K7151_1)
Scheda Splitter #1
Scheda Pannello Pulsanti
TG1K3A151_0
TG5 4A141_0
Scheda Regolatore TG1K1A151_1
Trasformatore Alimentazione Servizi E1KDRAUX
Cables RG302 (75 Ohm) #1 (COD:
CSF0027)
Cables RG178 (50 Ohm) #1
Cables RG179 (75 Ohm) #1
CSF0009
CSF0012
SYSTEMS 1+1 – N+1X
DOUBLE EXCITER SYSTEMS
1+1 ACTIVE RESERVE SYSTEMS
1+1 PASSIVE RESERVE SYSTEMS
N+1X SYSTEMS
ECHOS CHANGEOVER CONTROLLER
500W+500W
2XETG500 DR CHANGEOVER SYSTEM
2000W DUAL EXCITER
ET2000 DUAL DRIVE TRANSMITTER
3500W+500W
ET3500 TRANSMITTER + ETG500 DR AS RESERVE
5000W+2000W
EK5000 TRANSMITTER + ET2000 DR AS RESERVE
4+1 10KW SYSTEM
TELEMETRY
The telemetry can be connected to equipment of any other broadcast producer through analogue or digital inputs/outputs, or to the brand new generation of Elenos equipment via its RS 485 port.
It is provided with 8 digital inputs, 8 analog inputs, 8 outputs dry contacts relay outputs,
GSM modem, battery, Battery charger, led bar visualizing the GSM signal level, RS232 and
RS485 ports.
The user can see parameters and give commands to the equipment via connection between Modem and PC and via SMS.
Name, scale and alarm threshold of parameters are programmable through linear or logarythmic conversion, therefore any tipe of parameter can be seen in perfect scale:
Voltage, Amperage, Power, Temperature etc.
All inputs are programmable to generate and send SMS alarms. For example, the user can program the telemetry to send an alarm when the transmitter power goes under a set threshold, when the site door is open or it temperature on site is too high and so on.
The outputs can be programmed at dry contacts normally open or closed, or at negative or positive impulse.
The connection to PC is made using Windows standard Hyperterminal, therefore it is not only intuitive and easy-to-use, but also there is no need of a specific software installation. It uses a ASCII protocol and it's easily adaptable to other producers' software.
Thank to the internal battery, it sends an SMS in case of mains interruption.
A led bar on the front panel indicates the signal level of the GSM modem thanks to which it is easy to adjust the antenna for a better reception.
SOLAR PANNEL
MINIBOX
RADIO LINK RECEIVER – ELR SERIES
MAIN FEATURES
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
New functions and characteristics such as “Noise” and “Subcarrier” alarms.
Microprocessor controlled.
Large LCD graphics display show running parameters and settings.
Direct, low noise, frequency Synthesizer with 10KHz steps.
Frequency reference with high stability TCXO.
Extremely simple frequency changing.
Inputs, outputs and controls on front panel.
Automatic switching between AC 110/220V and DC 12.5V supplies.
High selectivity, double conversion.
Very low noise, low distortion digital pulse demodulator (no calibration required).
MPX processor with double low pass filter, amplitude and delay equalisation.
2 in-phase and 1 opposite-phase MPX outputs.
1 linear or or de-emphasised Mono output with 15KHz low pass filter.
Remote telecontrol output alarms on front panel.
IF 10.7MHz monitor on front panel.
• Slides out for easy maintenance and repairs.
SOME OF THE AVAILABLE FUNCTIONS
Main window from which you can access to measures and setup menu. The equipment’s operation can be observed from this window i.e. the reception frequency, PLL and squelch status, frequency deviation and reception signal. Your logo or trademark can be put in the square at the top left.
Frequency setting window. Scroll the “UP” and “DOWN” buttons with increasing speed until you reach the desired frequency and memorise with the “STORE” button. An analogical indicator shows the VCO’s working position.
The deviation value can be read as a composite of the MPX signal or as deviation due only to the pilot tone at 19KHz. In both cases the analogical indicator shows the peak number. Every time 75KHz are exceeded, the word “OverModulation” appears in the “Composite deviation” window. One new function of this type of equipment is its subcarrier alarm that indicates loss of 19KHz pilot tone and thus that there is no modulation (In MPX signals).
In this window’s SETUP menu you can set, the signal level at 0.1 dB steps directly for all the outputs in dBu
(0dBu=0.775V) for a 75KHz deviation.
The reception signal is measured on a log scale with a dynamic of 60dB.
Another window with the same scale allows to fix the threshold of the squelch in a precise way.
RADIO LINK TRANSMITTER – ELT SERIES
•
•
•
•
•
MAIN FEATURES
•
•
•
•
•
•
•
•
User interface with graphic display (240X64 pixels) and simple and intuitive menus.
Direct low noise Frequency Synthesizer with 10KHz steps.
Frequency reference with high stability TCXO
6 watts RF output power.
Completely wide band (no calibration necessary over the whole range).
Automatic power control (APC) for a constantly stable power.
Wide choice of measurements: Direct and reflected power; internal air and RF amplifier temperatures; composite and MPX-Subcarrier frequency deviation; RDS and SCA frequency deviation
Protection of reflected power with gradual reduction of output power (and reset) without stopping apparatus.
RDS and SCA audio inputs on the front panel. RF output on front or back panel.
Recognition and automatic (or manual) addressing of MPX and Mono signals.
All operating parameters adjustable without opening the apparatus.
AC 110/220V and DC 12.5V supply with automatic switch-over.
Alarm outlet for remote controls on the front panel (optional).
• Drawer type mechanism for taking out the frame and ease of maintenance and repairs.
SOME OF THE AVAILABLE FUNCTIONS
The main window from which you can access the measures and setup menu. This window also gives the operational state of the apparatus, the transmission frequency and the state of the PLL, information on
Audio input and measurement of the deviation and output power. The panel in the top left corner can be used for insertion of your own logo or trademark.
Frequency setting window. With the “Up” and “Down” keys you can move, with increasing speed, in steps of 10KHz to the desired frequency which is then memorised with the “Store” button. An analogue indicator bar showing the VCO working position with lighting up of the writing “Out of Range” if the frequency setting is wrong.
Special care has been given to all the variable measurements thanks to the use of a vhighly accurate 12bit ADC. In particular, measurement of the deviation parameter, very important in a transmitter, can be done for the total deviation, the MPX pilot frequency tone and any SCA or RDS sub-carriers present. For all measurements there is an analogue bar or numeric indicator.
“SETUP” menu window from which it is possible to adjust the output power. The value set remains stable over the entire frequency range thanks to the APC system (automatic power control). In the presence of stationery waves the system reduces proportionately the output power without stopping the apparatus and resetting the full power when the anomaly stops.
Window from which the input Audio signal parameters can be set. It is possible to set input impedance, pre-emphasis and signal type (Mono or MPX). Selecting the “Auto” mode the type of signal used in the
“Audio In” input is recognised and addressed automatically.
Input Audio level adjustment window. Sliding the “UP” and “DOWN” keys fixes the signal input level (“IN
Lvl” bar) and the deviation obtained can be seen simultaneously. The transmitter is calibrated for 75KHz deviation with an Audio signal of 0 dBu.
advertisement