OKOndt GROUP Sonocon B Quick Start Manual
Add to My manuals32 Pages
The OKOndt GROUP Sonocon B is a powerful ultrasonic flaw detector designed for a wide range of applications. It features a user-friendly interface and a comprehensive set of tools for flaw detection, thickness measurement, and data analysis. The device is equipped with advanced features such as automatic gain control (AGC) and time-corrected gain (TCG) to enhance signal clarity and reduce the need for manual adjustments, giving you the accuracy and reliability you need to make informed decisions about the integrity of your materials.
advertisement
▼
Scroll to page 2
of
32
![OKOndt GROUP Sonocon B Quick Start Manual | Manualzz OKOndt GROUP Sonocon B Quick Start Manual | Manualzz](http://s2.manualzz.com/store/data/071825038_1-6eb7aa5a1b688be73dcb2635f67d9045-360x466.png)
ТМ Ultrasonic Flaw Detector SONOCON В Quick start guide С Common features В UT version features Т Thickness Gauge + version features www.oko-ndt.com Battery compartment door А-SCAN MANIPULATION С H,mm - Full Screen H,us Y,mm RECTIFICATION CHOICE С Negative halfwave Radio Frequency Positive halfwave Full wave -3- GATES MANIPULATION С H,mm GAIN MANIPULATION Gain adjustment Gain step variation С С 0dB N, dB 38dB Add / remove some number of dB Reference gain В 80% 50% Put signal to the reference level В (80% or 50%) -4- В MENU NAVIGATION AND С PARAMETERS ADJUSTMENT В INDICATION PANEL Gain Sound Probe frequency velocity Indicators panel Probe angle Probe zero -5- Measurands INDICATORS N dB addition to the current gain: Reference gain mode: В +dB / +dB - Not added / Added dBr / dBr - Off / On AGC: AGC / AGC - Inactive / Active TCG: TCG / TCG - Inactive / Active DAC system: DAC / DAC - Inactive / Active DGS system: DGS / DGS - Inactive / Active AWS rating: AWS / AWS - Inactive / Active Measurement threshold: Measurement mode: 1 / - Edge / Peak / 1-2 / 2-C1 / - ... - Reference level for amplitude Reference level: 50% / 80% measurement in % of vertical scale Probe type: / Rectification mode: / / / Signal freeze modes: / / / Zoom modes: / / Direct manipulation modes: Battery indicator: 1, 2 – gates 1 and 2; C1, C2 – cursors 1 and 2. - Single element / Dual element Radio Frequency / Full wave / Positive half waves / Negative half waves - Off / Frozen / Frozen + Live signals / Estimate mode - Off / Zooming gate 1 / Zooming gate 2 / ASC / G1 / G2 - Off / A-Scan manipulation / Gate 1 manipulation / Gate 2 manipulation - Full / … / Almost empty ... -6- MENU STRUCTURE In UT software version there are 3 sets of main menu - up to your choice: user chosen menus user chosen menus В In Thickness Gauge+ software version there is only one menu type: Т -7- QUICK ACCESS В TO MAIN PARAMETERS UT-B 1. Measurement and alarm «Gates choice for Flaw Alarm System» «Time/distance measurement threshold choice» «Measurement point marker» PEAK EDGE «Choice of the gate(s) level for the sound alarm» «Choice of gate(s) and cursor(s) for absolute or relative measurements» Absolute by gate 1 ALARM SOUND ACCEPT. ALARM SOUND ALARM SOUND OFF RECORD Relative between gate 1 and gate 2 ALARM SOUND SEARCH Relative between gate 1 and cursor 2 -8- QUICK ACCESS В TO MAIN PARAMETERS UT-B 2. Measurands choice Maximum signal amplitude, relative to the reference level ∆ A off Par. 1 AWS rating Par. 4 Main parameter D Par. 2 Equivalent area of the indication Gain, necessary to get maximum signal to the reference level Par. 3 Se Equivalent diameter of the indication H Distance to the indication along the beam X De Y -9- Distance to the indication projection to the scanning plane Indication depth QUICK ACCESS В TO MAIN PARAMETERS UT-B 3. Display options «Switching measurement units» «Switching color schemes» Light «Display brightness adjustment» -10- Dark «Interface language choice» INDICATION SEARCH, В EVALUATION AND DOCUMENTATION AIDS Evaluate mode Helps finding the “best” signal. Just turn it on and scan. P 55dB G1 P P P 42dB 80% G1 Review all readings and save the indication if necessary - switches evaluate mode off and retrives the original gain -11- INDICATION SEARCH, В EVALUATION AND DOCUMENTATION AIDS Peak hold mode Saves the peak values of all signals along the A-Scan. P P P - Peak curve reset - Peak hold mode off Signals compare mode Displays both “frozen” and current signals. P 1 2 P 1 2 - Signals compare mode off -12- INDICATION SEARCH, В EVALUATION AND DOCUMENTATION AIDS Memory shortcuts. Results saving Smart zoom mode or -13- Probe STRAIGHT-BEAM В PROBES CALIBRATION -14- ANGLE-BEAM В PROBES CALIBRATION Calibration of the sound velocity and probe zero at V2 calibration block Probe 40 50 60 65 70 65 -15- 75 0 ANGLE-BEAM В PROBES CALIBRATION Probe angle calibration at V2 Set up probe zero and sound velocity in V2 before strating this calibration. Probe V2-1 0 40 50 60 65 α 65 0 70 40 50 60 65 α 70 65 Pr 75 V2-2 75 or ob e -16- ANGLE-BEAM В PROBES CALIBRATION Calibration of sound velocity and probe zero by block or testing object end Set up probe angle and X-value before starting this calibration Probe a Probe Probe a 2 xa -17- ANGLE-BEAM В PROBES CALIBRATION Calibration of sound velocity and probe zero by any reflectors with known location depth Set up probe angle before starting this calibration Probe Н1 1 2 Probe Н2 1 -18- 2 RAYLEIGH WAVE В PROBES CALIBRATION Calibration of probe zero at V1 block Set up probe angle = 90° before starting this calibration Probe 60 -19- 70 76 RAYLEIGH WAVE В PROBES CALIBRATION Calibration of probe zero at V2 block Set up probe angle = 90° before starting this calibration Probe 40 50 70 65 -20- 75 0 60 65 RAYLEIGH WAVE В PROBES CALIBRATION Calibration of sound velocity at testing object Set up probe angle = 90° before starting this calibration «Х01» -21- Probe BASIC PREPARATION FOR THICKNESS MEASUREMENT Т 1. Connect probe and select it in the probes list – PROBE → Probe type (add it to the list if necessary); 2. Calibrate probe zero (for details refer to next pages); 3. Set or calibrate sound velocity (for details refer to next pages); 4. Choose measurement type – MEASURE → Meas. type (0-1 by default); 5. Choose AGC mode MEASURE → AGC mode (Peak by default); 6. Specify such Maximum Gain Mode (MEASURE → MaxGain mode) and value of Maximum Gain (MEASURE → MaxGain) for manual mode, that Maximum Gain is high enough to raise back wall echoes at all thicknesses to be measured at necessary level and low enough that no noises come in the gate when probe is in the air; 7. Adjust scan and gate (for details please refer to the beginning of this guide) so that back wall echoes at all thicknesses to be measured are in the gate limits; 8. Choose PRF mode (MEASURE → PRF mode)– High by default or other in case if acoustic ghost signals are detected. ADDITIONAL PREPARATION Т FOR THICKNESS MEASUREMENT 1. Choose measurement threshold (MEASURE →Threshold: Edge / 0-Edge); 2. Choose measurement mode (MEASURE → Mode: Conventional / Min & Max / Differential / % of wear) and specify rated thickness for “Differential” and “% of wear” modes; 3. Specify measurement frequency; 4. Switch on measurement point marker (GTS & ALRM → Marker)(visible in zoom mode); 5. Set alarm bounds (GTS & ALRM →Tmin and Tmax), alarm mode (GTS & ALRM → Alarms), visualization (GTS & ALRM →Show alarm zones) and sound (GTS & ALRM →Sound). -22- ADDING NEW PROBE TO THE LIST Continued at the next page -23- Т CHOOSING CONNECTED Т PROBE FROM THE LIST -24- PROBE ZEROING Т Choose zero calibration mode (PROBE → Zero cal. mode: in air / on block) Zeroing in “in air” mode Pr ob e Zeroing in “on block” mode e ob Pr -25- FREE CALIBRATION Т Should be chosen in PROBE → Calibr.mode Prior to use free calibration all necessary preparations should be made and a thickness reading (can be incorrect) at the calibration block (or other object with known thickness) should be acquired. Probe Calibrating probe zero (sound velocity is already set) Н Probe Calibrating sound velocity (the probe is already zeroed) Н -26- 1-POINT CALIBRATION Т Should be chosen in PROBE → Calibr.mode Prior to use 1-point calibration it is necessary to specify the calibration block parameters in OPTIONS → Block 1pt menu. Probe Calibrating probe zero (sound velocity is already set) Probe Calibrating sound velocity (the probe is already zeroed) -27- 2-POINTS CALIBRATION Т Probe Should be chosen in PROBE → Calibr.mode Prior to use 2-point calibration it is necessary to specify the calibration blocks parameters in OPTIONS → Block 2pts-1 and Block 2pts-2 menus. Probe Н1 Н2 Thicknesses of calibration blocks for 2-points calibration should differ at least 2 times. -28- INDICATION PANEL Gain in gate 1 Т Gain in gate 2 AGC maximum gain Maximum gain mode Alarm lower thickness threshold Alarm upper thickness threshold Probe short name Probe number Probe zeroing mode Sound velocity Probe zero value Current file name Current file type Current place / point index along the 1st file dimension Current place / point index along the 3d file dimension Current place / point index along the 2nd file dimension Thickness value recorded in the current point or “free” or N/A 1 Indicators panel INDICATORS Т Radio Frequency / Full wave / - Positive half waves / Negative half waves Rectification mode: / Measurement threshold: / - Edge / 0-Edge (by zero crossing) / 1-2 - Direct manipulation: modes / ASC / G1 / G2 - Gate 1 manipulation / Indication of data collection condition at obtaining of slices / thickness maps: / / - Stopped / Active / Zoom modes: / / - Off / Zooming gate 1 / Measurement mode: Battery indicator: 1 / / Absolute (P-E) / Relative (E-E) measurements Off / A-Scan manipulation / Gate 2 manipulation Paused Zooming gate 2 - Full / … / Almost empty ... -29- QUICK ACCESS Т TO MAIN PARAMETERS TG+ 1. Gates choice for absolute or relative measurements «Choice of the measurement mode: absolute or relative» Absolute Relative «Measurement point marker» «Time/distance measurement threshold choice» EDGE Edge «Flaw alarm logic choice» Edge zero crossing Both "Too thin" and " Too thick” «Choice of the gate(s) level for the sound alarm» "Too Thick" only Оff "Too Thin" only -30- QUICK ACCESS Т TO MAIN PARAMETERS TG+ 2. Display options «Resolution choice» «Interface language choice» «Display brightness adjustment» «Measurement type choice» Normal «Switching color schemes» Light Dark Percents of wear Differential Min. and Max. fixation -31- CONTENTS С С С С В С В В В Т В В В В В Т Т Т Т Т Т Т Т Т Т Т A-Scan manipulation Rectification Choice Gates manipulation Gain manipulation Menu navigation and parameters adjustment Indication panel Indicators Menu structure Quick access to main parameters: UT-B 1. Measurement and alarm UT-B 2. Measurands choice UT-B 3. Display options Indication search, evaluation and documentation AIDS: Evaluate mode Peak hold mode Signals compare Memory shortcuts. Results saving Zoom mode Straight-beam probes calibration Angle-beam probes calibration: Calibration of the sound velocity and probe zero at V2 calibration block Probe angle calibration at V2 Calibration of sound velocity and probe zero by block or testing object end Calibration of sound velocity and probe zero by any reflectors with known location depth Rayleigh wave probes calibration: Calibration of probe zero at V1 block Calibration of probe zero at V2 block Calibration of sound velocity at testing object Basic preparation for thickness measurement Additional preparation for thickness measurement Adding new probe to the list Choosing connected probe from the list Probe zeroing Free calibration 1-point calibration 2-points calibration Indication panel Indicators Quick access to main parameters: TG+ 1. Gates choice for absolute or relative measurements TG+ 2. Display options 3 3 4 4 5 5 6 7 8 9 10 11 12 12 13 13 14 15 16 17 18 19 20 21 22 22 23 24 25 26 27 28 29 29 30 31
advertisement
Key Features
- Ultrasonic flaw detection
- Thickness gauge
- Multiple measurement modes
- Advanced signal processing
- Data logging and analysis
- User-friendly interface
- A-scan manipulation
- Gate manipulation
- Zoom mode
- Probe calibration
Related manuals
Frequently Answers and Questions
What types of probes can I use with the Sonocon B?
The Sonocon B supports both straight-beam and angle-beam probes. You can calibrate the probe angle and sound velocity for accurate measurements.
How do I calibrate the probe zero?
You can calibrate the probe zero in two modes: in air or on a block. Refer to the manual for detailed instructions.
What is the difference between the UT and Thickness Gauge+ software versions?
The UT version offers three sets of main menus for advanced functionality, while the Thickness Gauge+ version provides a single menu optimized for thickness measurement.