Selection Guide
E300 Electronic Overload Relay
Bulletin Numbers 193, 592
E300 Electronic Overload Relay
What’s Inside
Topic
Bulletin 193/592-E300 Overview
Bulletin 193/592-E300 Product Selection
Bulletin 193/592-E300 Specifications
Bulletin 193/592-E300 Approximate Dimensions
Page
2
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
Overview
Bulletin 193/592-E300 Overview
The E300 Electronic Overload Relay is the newest technology for overload protection. Its modular design, communication options, diagnostic information, simplified wiring, and integration into Logix make this the ideal overload for motor control applications in an automation system.
E300 Electronic Overload Relays provide the following benefits:
•
Intelligent motor control (EtherNet/IP enabled)
•
Scalable solution
•
Diagnostic Information
•
Integrated I/O
•
Adjustable trip class 5…30
•
Wide current range
•
Test/Reset button
•
Programmable trip and warning settings
•
True RMS current/voltage sensing (50/60 Hz)
•
Protection for single- and three-phase motors
NOTE: Your order must include 1) the Cat. No. of the sensing module, control module, and communication module selected, and 2)if required, Cat. No. of any accessories.
Standards Compliance and Certifications
Certifications Standards Compliance
UL508
UL1053 (Class I and Class II)
UL 60947-1
UL 60947-4-1
EN 60947-1
EN 60947-4-1
CSA22.2, No. 14
CSA22.2, No. 60947-1
CSA22.2, No. 60947-4-1
GB 14048.4
UL Listed
CE Marked
CSA Certified
CCC
KCC
Product Overview
The E300 consists of three modules: sensing, control and communications. Users have choices in each of the three with additional accessories to tailor the electronic overload for their application’s exact needs.
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
3
Overview
Sensing Module
Sensing Options
•
Voltage/current/ground fault
•
Current/ground fault
•
Current
Current Range [A]
•
0.5…30
•
6…60
•
10…100
Control Module
Control Voltage
110…120V AC, 50/60 Hz
220…240V AC, 50/60 Hz
24V DC
(1) Includes PTC thermistor and external ground fault.
Inputs
4
4
6
I/O
Relay Outputs
3
3
3
Inputs
2
I/O and Protection
(1)
Relay Outputs
2
2
4
2
2
Communication Module
•
EtherNet/IP
Expansion Digital I/O
Users can add up to four additional expansion digital modules to the E300 expansion bus.
•
4 inputs/2 relay outputs
•
24V DC
•
120V AC
•
240V AC
Expansion Analog I/O
Users can add up to four additional expansion analog modules to the E300 expansion bus.
•
3 universal analog inputs/1 analog output
•
0…10V
•
0…5V
•
1…5V
•
0…20 mA
•
4…20 mA
•
RTD (2-wire or 3-wire)
•
0…150
Ω
•
0…750
Ω
•
0…3000
Ω
•
0…6000
Ω
(PTC/NTC)
4
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
Overview
Expansion Power Supply
When more than one expansion digital module and one operator station are added to the E300 expansion bus, an expansion power supply is needed to supplement power for the additional modules. One expansion power supply will power a fully loaded E300 expansion bus.
•
120/240V AC
•
24V DC
Expansion Operator Station
One operator station can be added to the E300 expansion bus to be used as a user interface device. The operator stations provide E300 status LEDs and function keys for motor control. The operator stations also support CopyCat™, which allows user to upload and download E300 configuration parameters.
•
Control station
•
Diagnostic station
Thermal Overload
Thermal Utilization
The E300 Electronic Overload Relay provides overload protection through true RMS current measurement of the individual phase currents of the connected motor. Based on this information, a thermal model that simulates the actual heating of the motor is calculated. Percent of thermal capacity utilization (%TCU) reports this calculated value and can be read via a communications network. An overload trip occurs when the value reaches 100%.
Adjustable Settings
Thermal overload protection setup is accomplished simply by programming the motor’s full load current (FLC) rating and the desired trip class (5…30). Programming of the actual values through software programming ensures the accuracy of the protection.
Thermal Memory
The E300 Electronic Overload Relay includes a thermal memory circuit designed to approximate the thermal decay for a trip class 20 setting. This means that the thermal model of the connected motor is maintained at all times, even if the supply power is removed.
Reset Modes
This flexibility allows the end-user in the ability to select between manual and automatic reset for an overload trip, allowing for broad application. The point of reset is user adjustable from 1…100% TCU.
Time to Trip
During an overload condition, the E300 Electronic Overload Relay provides an estimated time to trip that is accessible via a communications network. This allows corrective action to be taken so that production may continue uninterrupted.
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
5
6
Overview
Time to Reset
Following an overload trip, the E300 Electronic Overload Relay will not reset until the calculated percentage of thermal capacity utilization falls below the reset level. As this value decays, the time to reset, which is accessible via a communications network, is reported.
Thermal Warning
The E300 Electronic Overload Relay provides the capability to alert in the event of an impending overload trip. A thermal warning bit is set in the Current Warning Status when the calculated percentage of thermal capacity utilization exceeds the programmed thermal warning level, which has a setting range of 0…100% TCU.
Two-Speed Protection
The E300 Electronic Overload Relay offers a second FLA setting for 2-speed motor protection. What used to require two separate overload relays - one for each set of motor windings - can now be accomplished with one device. Improved protection is delivered as thermal utilization is maintained in one device during operation in both speeds.
Overtemperature Protection (PTC and RTD)
The E300 Electronic Overload Relay provides motor overtemperature protection with the added provision for monitoring embedded positive temperature coefficient (PTC) thermistors with the E300 Control Module and resistance temperature detectors (RTD) with the E300 Analog Expansion Module. When the monitored PTC thermistors or RTD sensors exceed the programmed resistance level, the E300 Electronic Overload Relay can issue a Trip and/or Warning event.
Phase Loss
The E300 Electronic Overload Relay offers configurable phase loss protection, allowing the installer to enable or disable the function plus set a time delay setting, adjustable from 0.1…25.0 seconds. The trip level is factory-set at a current imbalance measurement of 100%.
Ground (Earth) Fault
The E300 Electronic Overload Relay incorporates zero sequence (core balance) sensing into its design for low level (arcing) ground fault detection. Trip and warning settings are adjustable from 20 mA…5.0 A. For devices rated greater than 200 A and for ground fault detection less than 0.5 A, the external core balance current transformer accessory is required. Class I and Class II protection are provided as defined by UL1053. The E300 Electronic Overload Relay provides a max. trip-inhibit setting, offering flexibility to prevent tripping when the ground fault current magnitude exceeds 6.5 A. This can be useful to guard against the opening of the controller when the fault current could potentially exceed the controller's interrupting capacity rating.
Note: The E300 Electronic Overload Relay is not a Ground Fault Circuit Interrupter for personnel protection as defined in article
100 of the U.S. National Electric Code.
Stall
"Stall" is defined as a condition where the motor is not able to reach full-speed operation in the appropriate amount of time required by the application. This can result in motor overheating as current draw is in excess of the motor’s full load current
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
Overview rating. The E300 Electronic Overload Relay provides user-adjustable stall protection. The trip setting has a range of 100…600%
FLA, and the enable time is adjustable up to 250 seconds.
Jam (Overcurrent)
The E300 Electronic Overload Relay can respond quickly to take a motor off-line in the event of a mechanical jam, thereby reducing the potential for damage to the motor and the power transmission components. Trip adjustments include a trip setting adjustable from 50…600% FLA and a trip delay time with a range of 0.1…25.0 seconds. A separate warning setting is adjustable from 50…600% FLA.
Underload (Undercurrent)
A sudden drop in motor current can signal conditions such as:
•
Pump cavitation
•
Tool breakage
•
Belt breakage
For these instances, rapid fault detection can help minimize damage and aid in reducing production downtime.
Additionally, monitoring for an underload event can provide enhanced protection for motors that are coded by the medium handled (e.g., submersible pumps that pump water). Such motors can become overheated despite being underloaded. This can result from an absence or an insufficient amount of the medium (due to clogged filters, closed valves, etc.).
The E300 Electronic Overload Relay offers underload trip and warning settings adjustable from 10…100% FLA. The trip function also includes a trip delay time with a range of 0.1…25.0 seconds.
Current Imbalance (Asymmetry)
The E300 Electronic Overload Relay offers current imbalance trip and warning settings adjustable from 10…100%. The trip function also includes a trip delay time with a range of 0.1…25.0 seconds.
Remote Trip
The remote trip function allows an external device (e.g., a vibration sensor) to induce the E300 Electronic Overload Relay to trip.
External device relay contacts are wired to the E300 Electronic Overload Relay discrete inputs. These discrete inputs are configurable with an option for assigning the remote trip function.
Voltage Protection
The E300 sensing module with voltage, current, and ground fault current will provide the user with enhanced current-based motor protection with the addition of voltage protection. With this option, users can protect against voltage issues (e.g., undervoltage, voltage imbalance, phase loss, frequency, and phase rotation).
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
7
Overview
Power Protection
While the motor is powering a load, the E300 sensing module with voltage, current, and ground fault current, will also protect the motor based on power. This option will monitor and protect for both excessive and low real power (kW), reactive power
(kVAR), apparent power (kVA), and power factor for a specific application (e.g., pump applications).
Analog Protection
The E300 analog expansion module allows you to protect against over-analog readings from analog-based sensors
(overtemperature, overflow, overpressure, etc.)
Current Monitoring Functions
The E300 Electronic Overload Relay allows the user to monitor the following operational data over a communications network:
•
Individual phase currents — in amperes
•
Individual phase currents — as a percentage of motor FLC
•
Average current — in amperes
•
Average current — as a percentage of motor FLC
•
Percentage of thermal capacity utilized
•
Current imbalance percentage
•
Ground fault current
Voltage, Power, and Energy Monitoring
The E300 sensing module with voltage, current, and ground fault current can be included in a company’s energy management system. This option will provide voltage, current, power (kW, kVAR, and kVA), energy (kWh, kVARh, kVAh, kW Demand, kVAR
Demand, and kVA Demand), and power quality (power factor, frequency, and phase rotation) information down at the motor level.
Diagnostic Functions
The E300 Electronic Overload Relay allows the user to monitor the following diagnostic information over a communications network:
•
Device status
•
Trip status
•
Warning status
•
Time to an overload trip
•
Time to reset after an overload
•
•
•
•
•
History of past five trips
History of past five warnings
Hours of operation
Number of starts
Trip snapshot trip
8
Status Indicators
The E300 Electronic Overload Relay provides the following LED indicators:
•
Power — This green/red LED indicates the status of the overload relay.
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
Overview
•
TRIP/WARN — This LED flashes a yellow code under a warning condition and a red code when tripped.
Inputs/Outputs
Inputs allow the connection of such devices as contactor and disconnect auxiliary contacts, pilot devices, limit switches, and float switches. Input status can be monitored via the network and mapped to a controller’s input image table. Inputs are rated
24V DC, 120V AC, or 240V AC and are current sinking. Power for the inputs is sourced separately with convenient customer sources at terminal A1. Relay contact outputs can be controlled via the network or DeviceLogix function blocks for performing such tasks as contactor operation.
Test/Reset Button
The Test/Reset button, located on the front of the E300 Electronic Overload Relay, allows the user to perform the following:
•
Test — The trip relay contact will open if the E300 Electronic Overload Relay is in an untripped condition and the Test/
Reset button is pressed for 2 seconds or longer.
•
Reset — The trip relay contact will close if the E300 Electronic Overload Relay is in a tripped condition, supply voltage is present, and the Test/Reset button is pressed.
Single/Three-Phase Operation
The E300 Electronic Overload Relay can be applied to three-phase as well as single-phase applications. A programming parameter is provided for selection between single- and three-phase operation. Straight-through wiring is afforded in both cases.
EtherNet/IP Communications
The E300 EtherNet/IP communication module has two RJ45 ports that act as an Ethernet switch to support a star, linear, and ring topology and supports the following:
•
2 concurrent Class 1 connections [1 exclusive owner + (1 input only or 1 listen only)]
•
6 simultaneous Class 3 connections (explicit messaging)
•
Embedded web server
•
SMTP server for trip and warning events (email and text messaging)
•
Embedded EDS file
•
RSLogix 5000 add-on profile
For more information on operation and maintenance of this product, please reference the user manual, publication 193-UM015.
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
9
Overview
Notes:
10
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
Product Selection
Bulletin 193/592-E300 Product Selection
Sensing Modules
Description
Current
Current/Ground Fault
Mounting Options
IEC Contactors
DIN Rail / Panel Mount Power
Terminals
DIN Rail / Panel Mount Power
Terminals.
Directly replaces 193-ECPM_
DIN Rail / Panel Mount Pass-thru
NEMA Contactors
IEC Contactors
DIN Rail / Panel Mount Power
Terminals
DIN Rail / Panel Mount Power
Terminals.
Directly replaces 193-ECPM_
DIN Rail / Panel Mount Pass-thru
NEMA Contactors
Current Range [A]
0.5…30
10…100
0.5…30
6…60
10…100
0.5…30
6…60
10…100
6…60
10…100
0.5…30
6…60
10…100
0.5…30
6…60
0.5…30
10…100
0.5…30
6…60
10…100
0.5…30
6…60
10…100
6…60
10…100
0.5…30
6…60
10…100
0.5…30
6…60
For Use With
100-C09…C23
100-C30…C55
100-C30…C55
100-C60…100-C97
All contactors and external current transformers
All contactors
All contactors and external current transformers.
All contactors
All contactors and external current transformers
All contactors
NEMA Size 0…2
NEMA Size 3
100-C09…C23
100-C30…C55
100-C30…C55
100-C60…100-C97
All contactors
NEMA Size 0…2
NEMA Size 3
592-ESM-I-100A-S3
193-ESM-IG-30A-C23
193-ESM-IG-30A-C55
193-ESM-IG-60A-C55
193-ESM-IG-100A-C97
193-ESM-IG-30A-T
193-ESM-IG-60A-T
193-ESM-IG-100A-T
193-ESM-IG-30A-E3T
193-ESM-IG-60A-E3T
193-ESM-IG-100A-E3T
193-ESM-IG-30A-P
193-ESM-IG-60A-P
193-ESM-IG-100A-P
592-ESM-IG-30A-S2
592-ESM-IG-60A-S2
592-ESM-IG-100A-S3
Cat. No.
193-ESM-I-30A-C23
193-ESM-I-30A-C55
193-ESM-I-60A-C55
193-ESM-I-100A-C97
193-ESM-I-30A-T
193-ESM-I-60A-T
193-ESM-I-100A-T
193-ESM-I-30A-E3T
193-ESM-I-60A-E3T
193-ESM-I-100A-E3T
193-ESM-I-30A-P
193-ESM-I-60A-P
193-ESM-I-100A-P
592-ESM-I-30A-S2
592-ESM-I-60A-S2
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
11
Product Selection
Description Mounting Options
IEC Contactors
DIN Rail / Panel Mount Power
Terminals
Voltage/Current/Ground Fault
DIN Rail / Panel Mount Power
Terminals.
Directly replaces 193-ECPM_
DIN Rail / Panel Mount Pass-thru
NEMA Contactors
Current Range [A]
0.5…30
6…60
10…100
0.5…30
6…60
10…100
0.5…30
6…60
10…100
0.5…30
0.5…30
6…60
10…100
For Use With
100-C09…C23
100-C30…C55
100-C30…C55
100-C60…100-C97
All contactors
External current and potential transformers
NEMA Size 0…2
NEMA Size 3
Control Modules
Description
I/O Module
I/O and Protection Module.
Thermistor (PTC) and External
Ground Fault Current
(1)
No. of Inputs/Outputs
6 in/3 out
4 in/3 out
4 in/3 out
4 in/2 out
2 in/2 out
2 in/2 out
(1) Requires Core Balanced Ground Fault Sensor Cat. No. 193-CBCT_.
Rated Control Voltage [V]
24V DC
110…120V AC, 50/60 Hz
220…240V AC, 50/60 Hz
24V DC
110…120V AC, 50/60 Hz
220…240V AC, 50/60 Hz
Cat. No.
193-EIO-63-24D
193-EIO-43-120
193-EIO-43-240
193-EIOGP-42-24D
193-EIOGP-22-120
193-EIOGP-22-240
Communication Modules
Description
EtherNet/IP
Cat. No.
193-ECM-ETR
Expansion Modules
Description
Digital Expansion Module, 24V DC
Digital Expansion Module, 120V AC
Digital Expansion Module, 240V AC
Analog Expansion Module: mA, V, RTD, and Resistance
Expansion Power Supply
Starter Control Station with 3-Meter Cable
Starter Diagnostic Station with 3-Meter Cable
(1) Module requires control module firmware v3.000 or higher.
No. of Inputs/Outputs
4 in/2 out
4 in/2 out
4 in/2 out
3 universal in/1 out
—
—
—
Rated Control Voltage [V]
24V DC
110…120V AC, 50/60 Hz
220…240V AC, 50/60 Hz
—
24V DC
110…240V AC, 50/60 Hz
—
—
Cat. No.
193-ESM-VIG-30A-C23
193-ESM-VIG-30A-C55
193-ESM-VIG-60A-C55
193-ESM-VIG-100A-C97
193-ESM-VIG-30A-T
193-ESM-VIG-60A-T
193-ESM-VIG-100A-T
193-ESM-VIG-30A-E3T
193-ESM-VIG-60A-E3T
193-ESM-VIG-100A-E3T
193-ESM-VIG-30A-CT
592-ESM-VIG-30A-S2
592-ESM-VIG-60A-S2
592-ESM-VIG-100A-S3
Cat. No.
193-EXP-DIO-42-24D
193-EXP-DIO-42-120
193-EXP-DIO-42-240
193-EXP-AIO-31
(1)
193-EXP-PS-DC
193-EXP-PS-AC
193-EOS-SCS
193-EOS-SDS
12
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
Accessories
Description
Contactor Coil Module
1-Meter Expansion Module Cable
3-Meter Expansion Module Cable
Core Balanced Ground Fault Sensor
Replacement Connectors
Panel Mount Screw Adapters
(1) Sold in multiples of 10. Order quantity of 10 to receive a package of 10 pieces.
(2) Sold in multiples of 10. Order quantity of 1 to receive a package of 10 pieces.
For Use With
100-C09…100-C23 contactors
100-C30…100-C55 contactors
100-C60…100-C97 contactors
—
—
193-EIOGP-42-24D
193-EIOGP-22-120
193-EIOGP-22-240
193-EIO-63-24D
193-EIO-43-120
193-EIO-43-240
193-EIOGP-42-24D
193-EIOGP-22-120
193-EIOGP-22-240
193-ESM-VIG-30A-CT
193-EXP-DIO-42-24D
193-EXP-DIO-42-120
193-EXP-DIO-42-240
193-EXP-AIO-31
193-EXP-PS-DC
193-EXP-PS-AC
193-ESM-I-30A-T
193-ESM-I-60A-T
193-ESM-IG-30A-T
193-ESM-IG-60A-T
193-ESM-VIG-30A-T
193-ESM-VIG-60A-T
193-ESM-I-30A-P
193-ESM-I-60A-P
193-ESM-IG-30A-P
193-ESM-IG-60A-P
193-ESM-VIG-30A-CT
193-ESM-I-100A-T
193-ESM-IG-100A-T
193-ESM-VIG-100A-T
193-ESM-I-100A-P
193-ESM-IG-100A-P
Product Selection
Cat. No.
193-EIO-CM-C23
193-EIO-CM-C55
193-EIO-CM-C97
193-EXP-CBL-1M
193-EXP-CBL-3M
193-CBCT1
193-CBCT2,
193-CBCT3
193-CBCT4
193-NCIO-63-CNT
193-NCIO-43-CNT
193-NCIOGP-42-CNT
193-NCIOGP-22-CNT
193-NCSM-VIG-CNT
193-NCXP-DIO-CNT
193-NCXP-AIO-CNT
193-NCXP-PS-CNT
140M-C-N45
(1)
193-ESM-SA-100
(2)
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
13
Product Selection
Notes:
14
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
Specifications
Bulletin 193/592-E300 Specifications
Wiring Diagrams
Figure 1 - Control Module
193-EIO-_ _-_ _ _ 193-EIOGP-_ _-_ _ _
A1 R03 R04 A2 IN0
IN1
RELAY 0
Additional Inputs for 193-EIO-63-_ _ _
A1 R03 R04 A2 IN0
IN1
RELAY 0
Additional Inputs for 193-EIOGP-42-_ _ _
A1 A1 A2
(+) (-)
IN2 IN3 IN4 IN5
RELAY 1 RELAY 2
PE R13 R14 R23 R24 A1 A1 A2
(+) (-)
IN2 IN3 IT1
PTC
IT2 PE
R13
RELAY 1
R14 S1
Ground
Fault
S2
+
t
Figure 2 - Expansion Digital I/O Modules 193-EXP-DIO-__
R04 R14 RC3
IN2 IN3
IN0 IN1 INC
+
Source
-
IN0 IN1 IN2 IN3 INC
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
15
Specifications
Figure 3 - Expansion Analog I/O Module 193-EXP-AIO-31
OUT+OUT-
IN2+ IN2- RS2
+
24V DC
Power
Supply
-
Analog Current Input
Current
Input
Device
INx+
INx-
IN1+ IN1- RS1
2 Wire RTD/Resistance
INx+
IN0+ IN0- RS0
INx-
Analog Voltage Input
+V INx+
-V
INx-
3 Wire RTD
INx+
INx-
RSx
Analog Voltage or Current Output
Out+
Out-
+
Device
-
Figure 4 - Expansion Power Supplies 193-EXP-PS-__
A1 A2
A1 A2
Electrical Specifications
Motor/Load Ratings
Terminals
Rated Insulation Voltage U i
Rated Operating Voltage U e,
IEC
Rated Operating Voltage U e,
UL
Rated Impulse Voltage (U imp
Rated Operating Current
I
Rated Frequency e
)
1/L1, 3/L2, 5/L3, 2/T1, 4/T2, 6/T3
690V AC
690V AC
690V AC
6 kV
See product selection table
45…65 Hz
(1)
(1) Exception: Any E300 Overload Relay that uses an external ground fault sensor is limited to
50/60 Hz detection.
16
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
Control Module Power Supply Ratings
Rated Supply Voltage (U s
)
Operating Range
Maximum Inrush Current
Maximum Power Consumption
E300:
E300 with expansion:
Maximum Power Interruption Time
V min
:
V max
:
24V DC
11…30V DC
3 A for 30 ms
5 ms
5 ms
120V AC
85…132V AC
10 A for 1 ms
6 W
8 W
10 ms
10 ms
240V AC
159…265V AC
8 A for 3 ms
10 ms
10 ms
Output Relay Ratings (Control Module and Expansion Digital Module)
Relay 0:
Relay 1:
Relay 2:
Type of Contacts
Rated Thermal Current (
I
the
)
Rated Insulation Voltage (U i
)
Rated Operating Voltage (U e
)
Rated Operating Current (
I
e
Minimum Operating Current
Rating Designation
Utilization Category
Short Circuit Current Rating
)
Resistive Load Rating (p.f. = 1.0)
Inductive Load Rating (p.f. = 0.4) (L/R = 7 ms)
Recommended Control Circuit Fuse
Rated Number of Operations
Relay 0, Relay 1, and Relay 2:
W/100-C09…100-C55
W/100-C60…100-C97
W/NEMA Size 0…2
W/NEMA Size 3
R03/R04
R13/R14
R23/R24
Form A SPST - NO
5 A
300V AC
250V AC
3 A (@120V AC), 1.5 A (@240V AC)
0.25 A (@110V DC), 0.1 A (@220V DC)
10 mA @ 5V DC
B300
AC-15
5 A, 250V AC
5 A, 30V DC
2 A, 250V AC
2 A, 30V DC
1,000 A
KTK-R-6
(6 A, 600 V)
5,000,000
2,500,000
1,000,000
300,000
Specifications
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
17
Specifications
Input Ratings (Control Module and Expansion Digital Module)
Input 0:
Input 1:
Input 2:
Input 3:
Input 4:
Input 5:
Supply Voltage
Type of Inputs
On-State Voltage
On-State Current (turn-on)
Off-State Voltage
Off-State Current
Transition Voltage
Transition Current
24V DC
11V DC
2 mA
5V DC
1.5 mA
5...11V DC
1.5...2.0 mA
IN0
IN1
IN2
IN3
IN4
IN5
120V AC
Current Sinking
74V AC
5 mA
20V AC
2.5 mA
20…74V AC
2.5…5 mA
240V AC
159V AC
5 mA
40V AC
2.5 mA
40…159V AC
2.5…5 mA
Analog I/O Ratings (Expansion Analog Module)
Bus to In/Out isolation
Group Isolation (In/Out)
Channel to channel isolation
Max. current draw
Max. Surge Current at Power-Up
Input ranges
Input Impedance Tolerances
Input resolution
Output ranges
Output Resolution
Voltage Output Load
Current Output Load
Output Impedance
Output Open Circuit detect
Max Inductive Load (current outputs)
Max Capacitive Load (voltage outputs)
Module
1000V AC = 1415V DC (1 min.)
1000V AC = 1415V DC (1 min.)
None
85 mA at 24V
0.5 A @ 24V DC for 1 ms
Input Channels
Current: 0…20 mA, 4…20 mA
Voltage: 0…10V, 1…5V, 0…5V
RTD: 100
Ω
, 200
Ω
, 500
Ω and 1000
Ω
PT385 and Pt3916, 100
Ω
Ni618 and Ni672, 10
Ω
Cu 426, 604
Ω
NiFe 518
Resistance: 0-150
Ω
, 0-750
Ω
, 0-3000
Ω
, 0-6000
Ω
Current Impedance: 249
Ω
± 1.0%
Voltage Impedance:
10M at 10V in
4M at 5V in
680k at 1V in
12 bits
Output Channels
Current: 0…20 mA, 4…20 mA
Voltage: 0…10V, 0…5V, 1…5V
12 bits
2k
Ω
min. at 10V output (5 mA max.), including wire resistance
50
Ω minimum to 750
Ω
max
Current: >1M
Ω
, Voltage: <1
Ω
Current outputs: O.C. detect supported
Voltage outputs: O.C. detect not supported
0.1 mH
1
μ
F
18
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
Specifications
Thermistor/PTC Input Ratings (PTC only)
Terminals
Type of Control Unit
Maximum Number of Sensors
Maximum Cold Resistance of PTC Sensor Chain
Trip Resistance
Reset Resistance
Short-circuit Trip Resistance
Maximum Voltage @ PTC Terminals (R
PTC
= 4 k
Ω
)
Maximum Voltage @ PTC Terminals (R
PTC
=open)
Response Time
IT1, IT2
Mark A
6
1500
Ω
3400
Ω
± 150
Ω
1600
Ω
± 100
Ω
25
Ω
± 10
Ω
7.5V DC
30V DC
800 ms
Low Voltage Directive
The E300 Electronic Overload Relay expansion digital modules are tested to comply with EN60947-5-1 Low-voltage switchgear and controlgear Part 5-1: Control circuit devices and switching elements.
Expansion Digital I/O Modules
Expansion Digital I/O Modules
Digital Output Rated Operational Voltage (U e
)
Digital Output Rated Insulation Voltage (U i
)
Rated Impulse Withstand Voltage (U imp
)
Conditional Short-Circuit Current
Recommended Control Circuit Fuse
Utilization Category
Pollution Degree
193-EXP-DIO-42- 24D
250V AC
2000V rms
for 1 s
NA
1000 A
KTK-R (6 A, 600V)
AC15, DC13
3
Expansion Power Supply Modules
Expansion Digital I/O Modules
Rated Operational Voltage (U e
)
Rated Insulation Voltage (U i
)
Rated Impulse Withstand Voltage (U imp
)
Conditional Short-Circuit Current
Protection against Short Circuits
Utilization Category
Pollution Degree
193-EXP-PS-AC
100…250V AC
2640V rms
for 1 s
4 kV
NA
NA
NA
3
193-EXP-DIO-42- 120
250V AC
2000V rms
for 1 s
NA
1000 A
KTK-R (6 A, 600V)
AC15, DC13
3
193-EXP-PS-DC
21.6…26.4V DC
500V for 60s
0.5 kV
NA
NA
NA
3
193-EXP-DIO-42- 240
250V AC
2000V rms
for 1 s
NA
1000 A
KTK-R (6 A, 600V)
AC15, DC13
3
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
19
Specifications
Environmental Specifications
Note: The E300 Electronic Overload Relay expansion power supplies (Cat. Nos. 193-EXP-PS-AC and 193-EXP-PS-DC) surrounding air temperature must not exceed 55 °C (131 °F).
Ambient Temperature
Storage
Operating (open)
Operating (enclosed)
–40…+85 °C (–40…+185 °F)
–20…+55 °C (–4…+131 °F)
–20…+40 °C (–4…+104 °F)
Humidity
Operating
Damp Heat – Steady State (per IEC 68-2-3)
Damp Heat – Cyclic (per IEC 68-2-30)
Cooling Method
Vibration (per IEC 68-2-6)
Shock (per IEC 68-2-27)
Maximum Altitude
Pollution Environment
Terminal Marking
Degree of Protection
5…95% Non-condensing
92% r.h., 40 °C (104 °F), 56 days
93% r.h., 25 °C/40 °C (77 °F/104 °F), 21 Cycles
Natural convection
2.5 G operating, 5 G non-operating
30 G
2000 m
(1)
Pollution Degree 3
EN 50012
IP20
(1) Exception: Any E300 Overload Relay that uses an external ground fault sensor is limited to 50/60 Hz detection.
Electromagnetic Compatibility Specifications
Test Level
Performance Criteria
Electrostatic Discharge Immunity
8kV Air Discharge, 6kV Contact Discharge
1
(1)(2)
Test Level
Performance Criteria
Radio Frequency Immunity
10V/m
Electrical Fast Transient/Burst Immunity
Test Level
Performance Criteria
4kV (Power), 2kV (Control & Comm)
Test Level
Performance Criteria
Radiated Emissions
Conducted Emissions
Surge Immunity
2kV (L-E), 1kV (L-L)
Class A
Class A
(1) Performance Criteria 1 requires the DUT to experience no degradation or loss of performance
(2) Environment 2
20
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
Protection
General Protection
Overload
Phase Loss
Ground Fault
Stall
Jam
Underload
Thermistor (PTC)
Current Imbalance
Communication Fault
Communication Idle
Remote Trip
Blocked Start/Start Inhibit
Under Voltage L-L
Over Voltage L-L
Voltage Unbalance
Phase Rotation
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Trip Warning
Yes Yes
Yes
Yes
No
Yes
No
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Overload Protection
Type of Relay
Nature of Relay
FLA Setting
Trip Rating
Trip Class
Reset Mode
Overload Reset Level
Ambient Compensated Time-Delay Phase Loss Sensitive
Solid-State
See user manual
120% FLA
5…30
Automatic or Manual
1…100% TCU
Ground Fault Protection
Type
Intended Use
Classification (Per UL 1053)
External Protection Range
Internal Protection Range
Trip & Warning Time Delay
Protection Inhibit Time
Core Balanced
Equipment Protection
Class I and Class II
20…100 mA
100…500 mA
200 mA…1.0 A
1.0…5.0 A
0.5…5.0 A
0.1…25.0 s
0…250 s
Under Frequency
Over Frequency
Under Real Power (kW)
Over Real Power (kW)
Under Reactive Power Consumed (+kVAR)
Over Reactive Power Consumed (+kVAR)
Under Reactive Power Generated (-kVAR)
Over Reactive Power Generated (-kVAR)
Under Apparent Power (kVA)
Over Apparent Power (kVA)
Under Power Factor Lagging (-PF)
Over Power Factor Lagging (-PF)
Under Power Factor Leading (+PF)
Over Power Factor Leading (+PF)
Power Value Overflow (kW, kVAR or KVA)
Over Analog
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Trip Warning
Yes Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Specifications
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
21
Specifications
Accuracy
Metering
Current
Voltage
Power
±2% of Sensing Module Current Range
±2% of Sensing Module Voltage Range
±5% of Sensing Module Current and Voltage Range
Protection Timers
All E300 Electronic Overload Relay trip timers have a resolution of ±0.1 s or 0.1 s/25 s (whichever is greater).
22
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
Notes:
Specifications
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
23
Specifications
24
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
Approximate Dimensions
Bulletin 193/592-E300 Approximate Dimensions
Dimensions are in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
Figure 5 - E300 Overload Relay Mounted on Bulletin 100-C09…-C23 Contactor
45
(1.76)
87
(3.40)
35
(1.37) n 5 (0.18)
67 (2.65)
190 (7.49)
(ADD 5 mm (0.19 in.)
FOR CONTACTOR COIL
ON LINE SIDE)
37 (1.47)
FROM
CONTACTOR
MTG. HOLE
152 (5.98)
122 (4.81)
60 (2.36)
29 (1.14)
FROM
CONTACTOR
MTG. HOLE
122
(4.78)
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
25
Approximate Dimensions
Figure 6 - E300 Overload Relay Mounted on Bulletin 100-C30…-C37 Contactor
45
(1.76)
104
(4.10)
67 (2.65)
190 (7.49)
(ADD 5 mm (0.19 in.)
FOR CONTACTOR COIL
ON LINE SIDE)
122 (4.81)
37 (1.48) FROM
CONTACTOR
MTG. HOLE
152 (5.98) n 5 (0.18)
35
(1.374)
60 (2.36)
29 (1.13)
FROM
CONTACTOR
MTG. HOLE
122
(4.78)
Figure 7 - E300 Overload Relay Mounted on Bulletin 100-C43…-C55 Contactor
54
(2.12)
107
(4.21)
190 (7.49)
(ADD 5 mm (0.19 in.)
FOR CONTACTOR COIL
ON LINE SIDE)
67 (2.65)
37 (1.48) FROM
CONTACTOR
MTG. HOLE
152 (5.98)
34 (1.34)
FROM
CONTACTOR
MTG. HOLE n 5 (0.18)
45 (1.75)
60 (2.36)
45 (1.76)
122
(4.82)
26
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
Figure 8 - E300 Overload Relay Mounted on Bulletin 100-C60…-C97 Contactor
71.6
(2.82)
126.2
(4.97)
129.5
(5.10)
43.5
(1.71)
FROM
CONTACTOR
MTG. HOLE
91.6
(3.60)
235.1
(9.26)
(ADD 0.24 in. FOR
CONTACTOR COIL
ON LINE SIDE)
177.6
(6.99)
38.9
(1.53)
FROM
CONTACTOR
MTG. HOLE
135.2
(5.32)
Figure 9 - E300 Overload Relay Mounted on Bulletin 500 NEMA Size 0 and Size 1 Contactor
90
(3.56) n 6 (0.22)
5.4
(0.21)
Approximate Dimensions
101
(3.98)
157 (6.17)
180 (7.06)
249 (9.78)
35 (1.38)
70
(2.75)
12 (0.46)
125
(4.91)
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
27
Approximate Dimensions
Figure 10 - E300 Overload Relay Mounted on Bulletin 500 NEMA Size 2 Contactor
100.1 (3.94) n 5.58 (0.22)
183.9
(7.24)
219.2
(8.63)
275.59
(10.85)
40.13
(1.58)
80.01
(3.15)
11.68 (0.46)
124.71
(4.91)
28
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
Figure 11 - E300 Overload Relay Mounted on Bulletin 500 NEMA Size 3 Contactor
138.2
(5.44)
11.35
(0.45)
161.6
(6.36)
19.9
(0.78)
7.9
(0.31)
368
(14.49)
219.9
(8.66)
274.1
(10.79)
Approximate Dimensions
121
(4.76)
139.85
(5.51)
155.45
(6.12)
138.4
(5.45)
Figure 12 - E300 Overload Relay, 193-ESM-___-30A-E3T and -60A-E3T, DIN Rail/Panel Mounted
45
(1.764)
126
(4.94)
6 (0.24)
30
(1.18)
9 (0.33)
46 (1.81)
148 (5.83)
4 (0.16) q
4 (0.14)
135 (5.32)
6 (0.217)
101 (3.96)
4 (0.154) n 5 (0.17)
8 (0.30)
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
29
Approximate Dimensions
Figure 13 - E300 Overload Relay, 193-ESM-___-100A-E3T, DIN Rail/Panel Mounted
71.6
(2.82)
41.2
(1.62)
17.7
(0.70)
5.5
(0.22)
139.9
(5.51) q
76.6
(3.02)
60
(2.36)
130
(5.12)
41.4
(1.63)
141.5
(5.57)
4.05
(0.16)
Figure 14 - E300 Overload Relay, 193-ESM-___-30A-T and -60A-T, DIN Rail Mounted
SHOWN WITH PANEL MOUNT FEET ACCESSORY
CAT. NO. 140M-C-N45
11.35
(0.45) n 4.8
(0.189)
39
(1.53)
135
WITH MTG. FEET
30.1
(1.19) q
4.5
(0.18)
116.2
(4.58)
W/O MTG. FEET
125
(4.921)
124
(4.88)
5
(0.197)
45
(1.76)
30
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
Approximate Dimensions
Figure 15 - E300 Overload Relay, 193-ESM-___-100A-T, DIN Rail Mounted
120.7
(4.75)
W/O FEET q
11.4
(0.45)
41.2
(1.62)
WITH FEET
36.6
(1.44)
W/O FEET
SHOWN WITH PANEL MOUNT ACCESSORY
FEET CAT. NO. 193-ESM-SA-100
60
(2.36) q
52.9
(2.08)
139.9
(5.51)
WITH FEET
130
(5.12)
71.6
(2.82)
141
(5.55) n 5.8
(0.23)
Figure 16 - E300 Overload Relay, 193-ESM-___-30A-P, -30A-CT, and -60A-P, DIN Rail Mounted
11.35
(0.45)
FROM MOUNTING FOOT
MOUNTING HOLE TO
RESET BUTTON
21.5
(0.85)
FROM MOUNTING FOOT
MOUNTING HOLE TO
RESET BUTTON
106.3
(4.18)
W/O MTG. FEET
30.2
(1.19) q
102
(4.00)
W/ MTG. FEET n 4.8
(0.19)
91.5
(3.60)
108
(4.25)
W/ MTG. FEET
45
(1.76)
123.5
(4.86)
5
(0.20)
3 PIN CONNECTOR ONLY WITH
CAT. NO. 193-ESM-VIG-30A-CT
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
31
Approximate Dimensions
Figure 17 - E300 Overload Relay, 193-ESM-___-100A-P, DIN Rail Mounted
q
11.6
(0.46)
26.3
(1.04)
WITH FEET
106.3
(4.18)
W/O FEET
21.4
(0.84)
W/O FEET
SHOWN WITH PANEL MOUNT ACCESSORY
FEET CAT. NO. 193-ESM-SA-100 q
38.8
(1.53)
109.9
(4.33)
WITH FEET n 5.8
(0.23)
60
(2.36)
71.6
(2.82)
140.9
(5.55)
Figure 18 - E300 Digital Expansion Module 193-EXP-DIO-___
22.5
(0.89)
2 x 4.5 (0.18) dia.
100
(3.94)
98 (3.86) 87 (3.43)
80.75 (3.18)
120
(4.73)
32
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
Approximate Dimensions
Figure 19 - E300 Analog Expansion Module 193-EXP-AIO-31
22.5
(0.89)
2 x 4.5 (0.18) dia.
98 (3.86) 87 (3.43)
80.75 (3.18)
Figure 20 - E300 Expansion Power Supply 193-EXP-PS-___
45
(1.77)
4x 4.5 (0.18) dia
98
(3.86)
87
(3.43)
80.75 (3.18)
12
(0.47)
Figure 21 - E300 Starter Control Station 193-EOS-SCS
100
(3.94)
18.5
(0.73)
45 (1.77)
13.5
(0.53)
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
120
(4.73)
120
(4.73)
22.5 (0.89) dia.
33
Approximate Dimensions
Figure 22 - E300 Starter Diagnostic Station 193-EOS-SDS
100
(3.94)
18.5
(0.73)
70
(2.76) n 22.1
(0.87)
13.5
(0.53)
34
Rockwell Automation Publication 193-SG010D-EN-P - April 2015
Allen-Bradley, Rockwell Software, Rockwell Automation, and LISTEN. THINK. SOLVE are trademarks of Rockwell Automation, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
Publication 193-SG010D-EN-P - April 2015
Supersedes Publication 193-SG010C-EN-P - November 2014 Copyright © 2015 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 1 E300 Electronic Overload Relay
- 2 Table of Contents
- 3 Overview
- 3 Bulletin 193/592-E300 Overview
- 3 Standards Compliance and Certifications
- 3 Product Overview
- 5 Thermal Overload
- 6 Overtemperature Protection (PTC and RTD)
- 6 Phase Loss
- 6 Ground (Earth) Fault
- 6 Stall
- 7 Jam (Overcurrent)
- 7 Underload (Undercurrent)
- 7 Current Imbalance (Asymmetry)
- 7 Remote Trip
- 7 Voltage Protection
- 8 Power Protection
- 8 Analog Protection
- 8 Current Monitoring Functions
- 8 Voltage, Power, and Energy Monitoring
- 8 Diagnostic Functions
- 8 Status Indicators
- 9 Inputs/Outputs
- 9 Test/Reset Button
- 9 Single/Three-Phase Operation
- 9 EtherNet/IP Communications
- 11 Product Selection
- 11 Bulletin 193/592-E300 Product Selection
- 11 Sensing Modules
- 12 Control Modules
- 12 Communication Modules
- 12 Expansion Modules
- 13 Accessories
- 15 Specifications
- 15 Bulletin 193/592-E300 Specifications
- 15 Wiring Diagrams
- 16 Electrical Specifications
- 19 Low Voltage Directive
- 20 Environmental Specifications
- 20 Electromagnetic Compatibility Specifications
- 21 Protection
- 22 Accuracy
- 25 Approximate Dimensions
- 25 Bulletin 193/592-E300 Approximate Dimensions
- 36 Back Cover