advertisement
▼
Scroll to page 2
of
78
Propaq® M Service Manual December 2010 9650-0804-01 Rev. A ZOLL is a registered trademark, and SurePower is a trademark of ZOLL Medical Corporation. Propaq is a registered trademark of Welch Allyn, Inc. Nellcor is a trademark of Covidien. Oridion, Microstream, and FilterLine are registered trademarks of Oridion Systems, Ltd. All other trademarks and registered trademarks are property of their respective owners. Copyright © 2010 ZOLL Medical Corporation. All rights reserved. Table of Contents Preface Overview................................................................................................................................ 1 Safety Considerations............................................................................................................ 2 Additional Reference Material................................................................................................ 2 Conventions ........................................................................................................................... 3 Service Policy Warranty......................................................................................................... 3 Technical Service................................................................................................................... 3 Technical Service for International Customers ...................................................................... 4 Chapter 1 Maintenance Tests Propaq M Overview ............................................................................................................... 5 Calibration and Calibration Checks ....................................................................................... 7 NIBP Valve, Pump, and Tubing Integrity Tests .....................................................................11 Operational Tests ................................................................................................................. 14 Functional Verification Tests ................................................................................................ 21 Chapter 2 Troubleshooting Overview.............................................................................................................................. 33 Propaq M Error Messages ................................................................................................... 33 Chapter 3 Disassembly Procedures Overview.............................................................................................................................. 41 Required Equipment ............................................................................................................ 41 Safety Precautions............................................................................................................... 42 Modules ............................................................................................................................... 42 Removing the Handle .......................................................................................................... 43 Disassembling the Main Unit ............................................................................................... 44 Removing the Front Enclosure Module ............................................................................... 47 Removing the Display Module ............................................................................................. 49 Removing the EtCO2 and NIBP Modules ............................................................................ 51 Removing the Monitor Board and SpO2 Modules ............................................................... 55 Chapter 4 Life Cycle Counters Overview.............................................................................................................................. 57 9650-0804-01 Rev. A ZOLL Propaq M Service Manual i TABLE OF CONTENTS Chapter 5 Replacement Parts Overview.............................................................................................................................. 59 Replacement Parts .............................................................................................................. 60 Chapter 6 Functional Description Overview.............................................................................................................................. 63 Appendix A Overview.............................................................................................................................. 67 Propaq M Electrical Hardware Interconnect Diagram.......................................................... 68 Propaq M Signal and Power Interconnect Schematic.......................................................... 69 Appendix B Overview.............................................................................................................................. 71 ii 9650-0804-01 Rev. A Preface Overview ZOLL® Medical Corporation’s Propaq® M Service Manual is intended for the trained biomedical technician whose responsibility is to identify malfunctions and/or make repairs at the subassembly level. The Propaq M Service Manual has six main sections and two appendixes. Preface—Contains safety warnings and an overview of the manual’s contents. Be sure to review this section thoroughly before attempting to use or service the Propaq M unit. Chapter 1—Maintenance Tests describes the Annual Calibration Tests for NIBP and EtCO2 modules, Functional Tests that need to be run when a module has been repaired, and Operational Tests that need to be performed at regular intervals to augment the automatic testing the Propaq M does to ensure readiness. Chapter 2—Troubleshooting provides a listing of error messages to help the service technician detect faults and repair them. Chapter 3—Disassembly Procedures describes step-by-step procedures for removing subassemblies from the Propaq M unit. Chapter 4—Life Cycle Counters describes step-by-step procedures for setting life cycle counters after replacing modules in the Propaq M unit. Chapter 5—Replacement Parts List displays a complete list of ZOLL part numbers for field replaceable parts available for the Propaq M unit, allowing the service person to identify and order replacement parts from ZOLL. 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 1 PREFACE Chapter 6—Functional Description provides technical descriptions for the Propaq M major subassembly modules. Appendix A—Propaq M Electrical Hardware Interconnect Diagram and Propaq M Signal and Power Interconnect Schematic. Appendix B—Contains simulators and settings that may be used to assess the performance of the NIBP module. Safety Considerations The following section describes general warnings and safety considerations for operators and patients. Service technicians should review the safety considerations prior to servicing any equipment and read the manual carefully before attempting to disassemble the unit. Only qualified personnel should service the Propaq M unit. Federal (U.S.A.) law restricts this unit for use by or on the order of a physician. Safety and effectiveness data submitted by ZOLL Medical Corporation to the Food and Drug Administration (FDA) under section 510(K) of the Medical Device Act to obtain approval to market is based upon the use of ZOLL accessories such as patient cables and batteries. Only qualified personnel should disassemble the Propaq M unit. Do not discharge a battery pack except in a ZOLL SurePowerTM Charging Station. Do not use the Propaq M in the presence of flammable agents (such as gasoline), oxygen-rich atmospheres, or flammable anesthetics. Using the unit near the site of a gasoline spill may cause an explosion. Do not use the unit near or within puddles of water. Additional Reference Material In addition to this guide, there is a Propaq M Operator’s Guide which is a comprehensive reference work that describes all the user tasks needed to operate the Propaq M. 2 9650-0804-01 Rev. A Conventions Conventions WARNING! Warning statements describe conditions or actions that can result in personal injury or death. Caution Caution statements describe conditions or actions that can result in damage to the unit. Note: Notes contain additional information on using the monitor. Service Policy Warranty In North America: Consult your purchasing agreement for terms and conditions associated with your warranty. Outside of North America, consult ZOLL authorized representative. In order to maintain this warranty, the instructions and procedures contained in this manual must be strictly followed. For additional information, please call the ZOLL Technical Service Department 1-800-348-9011 in North America. Technical Service If the ZOLL Propaq M unit requires service, contact the ZOLL Technical Service Department: Telephone: 1-978-421-9655; 1-800-348-9011 Fax 1-978-421-0010 Have the following information available for the Technical Service representative: • Unit serial number. • Description of the problem. • Department where equipment is used. • Sample chart recorder strips or electronic log files documenting the problem, if applicable. • Purchase Order to allow tracking of loan equipment. • Purchase Order for a unit with an expired warranty. If the unit needs to be sent to ZOLL Medical Corporation, obtain a service request number (SR#) from the Technical Service representative. Return the unit in its original container to: ZOLL Medical Corporation 269 Mill Road Chelmsford, Massachusetts 01824-4105 Attn: Technical Service Department (SR#) Telephone: 1-800-348-9011; 1-978-421-9655 FAX: 978-421-0010 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 3 PREFACE Technical Service for International Customers International customers should return the unit in its original container to the nearest authorized ZOLL Medical Corporation Service Center. To locate an authorized service center, contact the International Sales Department at ZOLL Medical at the above address. 4 9650-0804-01 Rev. A Chapter 1 Maintenance Tests Propaq M Overview This chapter includes step-by-step procedures for the following types of maintenance tests: • • • • Calibration and Calibration Checks NIBP Valve, Pump, and Tubing Integrity Tests Operational Tests Functional Verification Tests At a minimum, a trained biomedical technician must perform a CO2 calibration and an NIBP calibration check once per year. A CO2 calibration check may be performed at any time to verify the CO2 calibration. The Troubleshooting chapter in this manual may recommend performing one of more of the NIBP valve, pump, and tubing integrity tests to help identify and correct potential issues with the NIBP valve, pump, and/or tubing. It is necessary to perform Functional Verification Tests after a module is repaired to ensure that the functions of the Propaq M unit work properly. Because the Propaq M units must be maintained ready for immediate use, it is important for users to conduct the Operator’s Shift Checklist procedure at the beginning of every shift. This procedure can be completed in a few minutes and requires no additional test equipment. (See the ZOLL Propaq M Operator’s Guide for the Operator’s Shift Checklist.) It is highly recommended that the Operational Tests be performed at regular intervals to augment the automatic testing the Propaq M does to ensure readiness. 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 5 CHAPTER 1 MAINTENANCE TESTS This chapter describes the following maintenance tests: Calibration and Calibration Checks • NIBP Calibration Check • CO2 Calibration Procedure • CO2 Calibration Check NIBP Valve, Pump, and Tubing Integrity Tests • Leak Test • Deflation Test • Inflation Test Operational Tests • Physical Inspection of the Unit • Keypad Test • LED Test • LCD Test • RFU Indicator Test • Audio Test • Battery Test • Fan Test • NIBP Test Functional Verification Tests • Leads Test • Heart Rate Display Test • Heart Rate Alarm Test • Leakage Current Test • SpO2 Monitor Test • EtCO2 Monitor Test • IBP Monitor Test • NIBP Monitor Test • Temperature Test 6 9650-0804-01 Rev. A Calibration and Calibration Checks Calibration and Calibration Checks NIBP Calibration Check Equipment Single lumen BP hose, a 500 cc volume, and a calibrated manometer or pressure gauge (< = 1mmHg accuracy). If a 500 cc volume is not available, an Adult BP cuff wrapped around a rigid cylinder (such as a glass jar) will suffice. Note: This test is to be performed for the following target pressures: 50 +/- 5 mmHg, 150 +/- 5 mmHg, and 250 +/- 5 mmHg. Procedure 1. Power on the Propaq M. 2. Connect the Propaq M to the single lumen hose and the 500 cc volume. Alternatively, replace the 500 cc volume with a standard Adult cuff wrapped around a rigid cylinder, such as a glass jar. Connect a calibrated manometer to the air line using a T-fitting. 3. On the Propaq M, do the following to enter the NIBP Test control panel: • Press the Setup quick access key ( ). • Use the navigation keys to select Supervisor>Service>Device Tests>NIBP Test. 4. From the Propaq M NIBP Test control panel, use the navigation keys to select: • Close Valve • Turn Pump On 5. Monitor the pressure reported by the external pressure standard. 6. Once the pressure reaches the target pressure of 50 +/- 5 mmHg, use the navigation keys to select Turn Pump Off. 7. Allow the system to stabilize for at least 10 seconds. 8. Record the pressure reported by the external pressure standard as Pa. 9. Record the pressures reported by the primary and safety transducers (displayed in the NIBP Test control panel) as Pp and Ps, respectively 10. Calculate the absolute pressure differences between the applied pressure (Pa) and each of the transducer pressures. • Pd-Primary = abs(Pa-Pp) • Pd-safety = abs(Pa-PS) 11. From the NIBP Test control panel, select Open Valve to release the pressure 12. Repeat steps 3 to 11 to test for the remaining target pressures of 150 +/- 5 mmHg and 250 +/ - 5 mmHg. 13. Once complete, use the navigation keys to select Update NIBP Cal Check Date to save the date of the most recent calibration check. 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 7 CHAPTER 1 MAINTENANCE TESTS Acceptable Results The unit passes the test if Pd-Primary is less than or equal to 3.0 mmHg and Pd-Safety is less than or equal to 4.0 mmHg for all three target pressures. Corrective Action If readings fail to meet the required accuracy, the NIBP module requires replacement or factory analysis and realignment. 8 9650-0804-01 Rev. A Calibration and Calibration Checks CO2 Calibration Procedure (required for annual calibration) Equipment 5% CO2 calibration gas cylinder with CO2 sample line (kit available from Scott Medical Products, PN 4653ORF-BD) Procedure 1. On the Propaq M, do the following to enter the CO2 Calibration control panel: CO2 • Press the CO2 quick access key ( CO ). • Use the navigation keys to select Supervisor>Service>Diagnostic>CO2>Calibration. 2. Connect the Propaq M to the 5% CO2 calibration gas cylinder using the sample line included with the calibration kit. 3. From the CO2 Calibration Menu, select Calibration. 4. Activate the calibration gas flow by pressing the top valve on the calibration gas canister. 5. Continue to apply the calibration gas until the status in the CO2 Calibration control panel displays: CALIBRATION GAS CAN BE REMOVED. • When the calibration is complete, the status in the CO2 Calibration control panel displays: CALIBRATION DONE - OK OR CALIBRATION DONE - ERROR. 6. To verify calibration, perform the CO2 Calibration Check Procedure on page 10. Acceptable Results The status in the CO2 Calibration control panel displays: CALIBRATION DONE - OK. Perform the above calibration check procedure to verify CO2 accuracy. The calibration date will be updated upon exiting the CO2 Test control panel. Corrective Action If an error is reported, refer to the table below for possible causes. If readings fail to meet the required accuracy, the CO2 module requires replacement or factory analysis and realignment. The following table describes possible calibration errors and likely causes. Table 1-1. Calibration Errors Error Message Cause No gas or wrong gas concentration The concentration of supplied gas is not close to the expected value. No stable gas flow and Calibration failure The gas sample is not stable, i.e. due to leak or noise. Measurement error Occlusion detection during known gas sampling. Measurement error Sample line disconnection during gas sampling. AZ fail The Auto Zero that is part of the calibration process failed. Calibration aborted by user Calibration mode canceled during gas sampling. 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 9 CHAPTER 1 MAINTENANCE TESTS CO2 Calibration Check Procedure Equipment 5% CO2 calibration gas cylinder with CO2 sample line (kit available from Scott Medical Products, PN 4653ORF-BD) Procedure 1. On the Propaq M, do the following to enter the CO2 Calibration control panel: CO2 • Press the CO2 quick access key ( CO ). • Use the navigation keys to select Supervisor>Service>Diagnostic>CO2>Calibration. 2. Connect the Propaq M to the 5% CO2 calibration gas cylinder using the sample line included with the calibration kit. 3. From the CO2 Calibration control panel, select Verify Calibration. 4. Activate the calibration gas flow by pressing the top valve on the calibration gas canister. 5. Continue to apply the calibration gas until the status in the CO2 Calibration control panel displays: CALIBRATION GAS CAN BE REMOVED. • When the calibration check is complete, the status in the CO2 Calibration control panel displays: VERIFICATION DONE - OK OR VERIFICATION DONE - ERROR. • When the calibration check completes successfully, the measured gas value displays in the CO2 Calibration control panel. Acceptable Results The message displays: VERIFICATION DONE - OK. The measured gas reading passes if it is between 4.8 and 5.2 (Vol%). Corrective Action If an error is reported, refer to Table 1-1 on page 9 for possible causes. If the measured gas reading is outside the acceptable range, or if calibration is due, complete the “CO2 Calibration Procedure (required for annual calibration)” on page 9. 10 9650-0804-01 Rev. A NIBP Valve, Pump, and Tubing Integrity Tests NIBP Valve, Pump, and Tubing Integrity Tests NIBP Leak Test Equipment Single lumen BP hose, a 500 cc volume, and a calibrated manometer. Note: If a 500 cc volume is not available, an Adult BP cuff wrapped around a rigid cylinder (such as a glass jar) will suffice Procedure 1. Power on the Propaq M. 2. Connect the Propaq M to the single lumen hose and the 100 cc volume. Alternatively, replace the 100 cc volume with a standard Adult cuff wrapped around a rigid cylinder, such as a glass jar. If available, connect a calibrated manometer to the air line using a T-fitting. 3. On the Propaq M, do the following to enter the NIBP Test control panel: • Press the Setup quick access key ( ). • Use the navigation keys to select Supervisor>Service>Device Tests>NIBP Test. 4. From the Propaq M NIBP Test control panel, use the navigation keys to select: • Close Valve • Turn Pump On 5. Monitor the pressure reported by NIBP Test control panel or the external pressure standard. 6. Select Turn Pump Off as soon as the pressure reaches the target pressure of 250 +/- 5 mmHg. 7. Allow the system to stabilize for 10 seconds. 8. Select Mark P1 to mark the starting pressure. If available, measure the starting pressure reported by the external pressure standard. Record the starting pressure as PS. 9. Wait 15 seconds. 10. .Select Mark P2 to mark the ending pressure. If available, measure the ending pressure reported by the external pressure standard. Record the ending pressure as PE. 11. From the NIBP Test control panel, select Open Valve to release the pressure. 12. Calculate the leak rate: L = (Ps - Pe) / (15 seconds). Note: If using the pressure reported in the NIBP Test control panel, calculate the Leak Rate using the Primary transducer pressures. Acceptable Results The unit passes the test if the system leaks less than 5 mmHg over the 15-second time interval (Leak Rate is less than 1/3). 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 11 CHAPTER 1 MAINTENANCE TESTS Corrective Action If the unit fails the test, the most likely cause is damaged or disconnected internal tubing. The device needs to be disassembled to replace or reattach the appropriate segment of NIBP tubing. The NIBP valves should also be inspected. 12 9650-0804-01 Rev. A NIBP Valve, Pump, and Tubing Integrity Tests NIBP Deflation Test Equipment Single lumen BP hose, a 500 cc volume, a timer, and a calibrated manometer (optional). Note: Note: If a 500 cc volume is not available, an Adult BP cuff wrapped around a rigid cylinder (such as a glass jar) will suffice. Procedure 1. Power on the Propaq M. 2. Connect the Propaq M to the single lumen hose and the 500 cc volume. Alternatively, replace the 500 cc volume with a standard Adult cuff wrapped around a rigid cylinder, such as a glass jar. If available, connect a calibrated manometer to the air line using a T-fitting. 3. On the Propaq M, do the following to enter the NIBP Test control panel: • Press the Setup quick access key ( ). • Use the navigation keys to select Supervisor>Service>Device Tests>NIBP Test. 4. From the Propaq M NIBP Test control panel, use the navigation keys to select: • Close Valve • Turn Pump On 5. Monitor the pressure reported by the NIBP Test control panel or the external pressure standard. 6. Select Turn Pump Off as soon as the pressure reaches the target pressure of 265 +/- 5 mmHg. 7. Allow the system to stabilize for 5 seconds. 8. Use the navigation keys to select Open Valve and immediately start the timer. 9. Stop the timer as soon as pressure drops below 15 mmHg. 10. Record the Deflation Time as TD. Acceptable Results The unit passes the test if the time to release pressure from 265 +/- 5 mmHg to 15 mmHg is less than 10 seconds. Corrective Action If the unit fails the test, the most likely cause is kinked or obstructed internal tubing, or obstructed filter. The device needs to be disassembled to replace or reposition the appropriate segment of NIBP tubing. 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 13 CHAPTER 1 MAINTENANCE TESTS NIBP Inflation Test Equipment Single lumen BP hose, a 250 cc volume, a timer, and a calibrated manometer (optional). Procedure 1. Power on the Propaq M. 2. Connect the Propaq M to the single lumen hose and the 250 cc volume. If available, connect a calibrated manometer to the air line using a T-fitting. 3. In the Propaq M, do the following to enter the NIBP Test control panel: 4. Press the Setup quick access key ( ). 5. Use the navigation keys to select Supervisor>Service>Device Tests>NIBP Test. 6. Wait 10 seconds to allow the system to vent any residual pressure. 7. Verify that the pressure reported by the NIBP Test control panel or the external pressure standard system is less than 5 mmHg. 8. From the NIBP Test control panel, use the navigation keys to select Close Valve. 9. Select Turn Pump On and immediately start the timer. 10. Stop the timer as soon as pressure exceeds 210 mmHg. 11. Select Turn Pump Off, then Open Valve. 12. Record the Inflation Time as TI. Note: Note: The pump will automatically turn off if pressure exceeds 310 mmHg during this test. Acceptable Results The unit passes the test if the time to increase pressure to 210 mmHg is less than 7 seconds. Corrective Action If the unit fails the test, the most likely cause is a faulty pump or a kinked internal hose. The device needs to be disassembled to replace the pump or reposition the appropriate segment of NIBP tubing. 14 9650-0804-01 Rev. A Operational Tests Operational Tests The Propaq M comes equipped with routine operational tests that can be performed periodically. With the exception of the Physical Inspection of the Unit test, these tests contain instructions within them provide guidance during the tests. Physical Inspection of the Unit Tools Needed None Test Setup None Observe this... Pass/Fail Housing 1. Is the unit clean and undamaged? o o 2. Does the unit show signs of excessive wear? o o 3. Does the handle work properly? o o 4. Does the recorder drawer open and close properly? o o 5. Are input connectors clean and undamaged? o o 6. Are there any cracks in the housing? o o 7. Do the front panel or selector switches have any damage or cracks? o o 8. Are there any loose housing parts? o o 12. Are all cables free of cracks, cuts, exposed or broken wires? o o 13. Are all bend/strain reliefs undamaged and free of excessive cable wear? o o 14. Is the Propaq battery fully charged? o o 15. Is the battery seated in the battery well correctly? o o 16. Is battery housing free of cracks and damage? o o 17. Are connectors free of damage and excessive wear? o o Cables Battery 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 15 CHAPTER 1 MAINTENANCE TESTS Accessing the Operational Tests The operational tests on the unit can be accessed by doing the following: 1. Press the Setup quick access key ( ). 2. Use the navigation keys to select Supervisor>Service>Device Tests. The operational tests are displayed. Use the navigation keys to select one of the tests. 16 9650-0804-01 Rev. A Operational Tests Keypad Test This test checks all the front panel buttons on the unit to make sure they are working correctly. Follow the instructions and use the navigation keys to move around the display and make selections. LED Test This test checks all the Light Emitting Diodes in the unit to make sure they are working correctly. Follow the instructions and use the navigation keys to move around the display and make selections. 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 17 CHAPTER 1 MAINTENANCE TESTS LCD Test This test checks the colors of the Liquid Crystal Display on the unit. Follow the instructions and use the navigation keys to move around the display and make selections. RFU Indicator Test This test checks the Ready For Use Indicator on the unit to make sure it is working correctly. Follow the instructions shown on the display. 18 9650-0804-01 Rev. A Operational Tests Audio Test This test checks the audio tones on the unit to make sure they are working correctly. Follow the instructions and use the navigation keys to move around the display and make selections. Battery Test This test checks the battery to make sure it is working correctly. Follow the instructions on the display. 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 19 CHAPTER 1 MAINTENANCE TESTS Fan Test This test checks the fan in the unit to make sure it is working correctly. Follow the instructions and use the navigation keys to move around the display and make selections. NIBP Test This allows the operator to perform various checks of the NIBP module to make sure it is working correctly. Follow the instructions in the NIBP Calibration Check procedure and other procedures outlined in this manual. Use the navigation keys to move around the display and make selections as required to execute the procedures. 20 9650-0804-01 Rev. A Operational Tests USB Test This test checks the USB capability in the unit to make sure it is working correctly. Follow the instructions and use the navigation keys to move around the display and make selections. 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 21 CHAPTER 1 MAINTENANCE TESTS Functional Verification Tests Before You Begin the Functional Verification Tests • Assemble the tools listed in following section, “Equipment You Need to Perform the • • • • • Functional Verification Tests.” Keep an extra fully charged Propaq M battery available. Schedule an hour to conduct the entire maintenance test. Perform the tests in the order presented. Perform all the steps of each test procedure. Complete all the steps of the procedure before evaluating the test results. Equipment You Need to Perform the Functional Verification Tests For testing purposes, you can substitute an equivalent device. • Fluke Impulse 7000DP Analyzer, or equivalent, with appropriate interface adapter (Dynatech Nevada Inc. part number 3010-0378) IBP/Temp Simulator, or equivalent NIBP Simulator Single or dual lumen NIBP hose Adult NIBP cuff and a rigid cylinder to wrap it around 5% CO2 calibration gas cylinder with CO2 sample line (kit available from Scott Medical Products, PN 4653ORF-BD) • ECG Simulator; 12 Lead Simulator for 12 Lead test (e.g., Symbio CS1201) • • • • • Accessories You Need for the Propaq M Options Functional Verification Tests • 3-lead, 5-lead and 12-lead ECG cables. (12-lead cable needed if 12-lead option is • • • • • • • 22 installed.) NIBP cuff and hose IBP cable SpO2 cable and sensor EtCO2 cable and sensor Paddles Battery Auxiliary power source 9650-0804-01 Rev. A Functional Verification Tests Leads Test Tools Needed 3-lead, 5-lead, and 12-lead cables Test each cable separately. Test Setup Connect the lead wires appropriate to each test to the Fluke Impulse 7000DP Analyzer or equivalent. Do this... Observe this... Pass/Fail 1. Press the power switch to turn on the No ECG LEAD FAULT message Propaq M. displayed. o o 2. Disconnect one lead from the simulator. The ECG LEAD FAULT message displays within 3 seconds (if configured). o o 3. Reconnect the lead. Repeat step 2 with the remaining leads. Wait for ECG LEAD FAULT message to clear from the display (if configured). o o o o 4. Repeat steps 2 and 3 for 5 lead and 12 Note: If heart rate alarm sounds, on the lead cables. Propaq M: • Press the Next quick access key ( ) key to access the second set of quick access keys. • Press the Alarm quick access key ( ). • Press the Alarm Suspend key ( ). 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 23 CHAPTER 1 MAINTENANCE TESTS Heart Rate Display Test Tools Needed ECG simulator ECG Cable (3-lead, 5-lead or 12-lead) Test Setup Press the power switch to turn on the Propaq M. Press Lead quick access key until II displays. Connect the ECG leads to the ECG simulator. Connect the ECG cable to the unit. 1. 24 Do this... Observe this... Pass/Fail Set the ECG Simulator to 120BPM. The Heart Rate displays as 120 +/- 4 bpm o o 9650-0804-01 Rev. A Functional Verification Tests Heart Rate Alarm Test Tools Needed ECG simulator Do this... Observe this... Pass/Fail 1. Press the power button on the Propaq M to turn the unit on. Connect the ECG leads to the ECG simulator. Set the simulator to 120 BPM and press the Leads quick access key ( I,III...II, ) on the Propaq M unit and select lead II. II displays next to the Leads quick access key. o o 2. On the Propaq M: The Alarm Settings menu displays. o o o o o o o o • Press the Next quick access key ( ) key to access the second set of quick access keys. • Press the Alarm quick access key ( ). • Press the Limits softkey. 3. On the Propaq M, select HR/PR Alarm in the Alarm Settings menu and use the navigation keys to do the following: • Set the Upper Limit Enable to ON. • Set the Lower Limit Enable to ON. • Set the Lower limit to 30. • Set the Upper limit to 150. Use the navigation keys to exit the Alarm Settings menu. 4. 5. 6. 7. On the Propaq M, press the Alarm Suspend key ( ). The red alarm suspension timer displays at the top of the next to the message area. Remove a lead wire from the ECG The ECG LEAD FAULT message simulator. displays. On the Propaq M, press the Alarm Suspend key ( ). The Alarm Suspend key flashes. Reattach ECG Lead wire to ECG The ECG LEAD FAULT message no longer displays. simulator. Set simulator to 20 BPM or lower. Heart Rate Value is highlighted and the alarm tone sounds. The HR/PR LOW ALARM message displays. 8. On the Propaq M, press the Alarm Suspend key ( ). The Alarm Suspend key flashes.The red alarm suspension timer displays at the top of the screen next to the message area. 9. Set the simulator to 120 BPM. 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 25 CHAPTER 1 MAINTENANCE TESTS Do this... Observe this... 10. On the Propaq M, press the Alarm Suspend key ( ). Alarm is enabled. The alarm suspend key flashes. The alarm suspension timer disappears. o o 10. Set simulator to 160 BPM or higher. Heart Rate Value is highlighted and the alarm tone sounds. The HR/PR HIGH ALARM message displays. o o 11. On the Propaq M, press the Alarm Alarm is suspended for 90 seconds. The alarm suspension timer appears in black. o o Silence/Reset button ( 26 ). Pass/Fail 9650-0804-01 Rev. A Functional Verification Tests SpO2 Test Tools Needed SpO2 Simulator: Fluke Index 2 or equivalent, NellcorTM SpO2 finger probe Test Setup Disconnect any ECG cable or IBP probes from the Propaq M. Do This... Observe This... 1. Power on the Propaq M without the SpO2 sensor attached. Verify that the SpO2 numeric displays INITIALIZING, changes to SEARCHING, then goes blank. 2. Connect the SpO2 sensor to the Propaq M. Verify that SpO2 numeric displays SEARCHING. 3. Set the simulator to 70% SpO2 and 60 PPM. Attach the SpO2 sensor to the simulator. Verify that after a brief period of initialization, the SpO2 numeric displays an SpO2 value between 67% and 73%. o o Verify that the displayed pulse rate reads 60 +/- 3 bpm. o o Verify that after a brief period of initialization, the SpO2 numeric displays an SpO2 value between 77% and 83%. o o Verify that the displayed pulse rate reads 60 +/- 3 bpm. o o Verify that after a brief period of initialization, the SpO2 numeric displays an SpO2 value between 87% and 93%. o o Verify that the displayed pulse rate reads 60 +/- 3 bpm. o o 4. 5. Set the simulator to 80% SpO2 and 60 PPM. Set the simulator to 90% SpO2 and 60 PPM. 9650-0804-01 Rev. A ZOLL Propaq M Service Manual Pass/Fail 27 CHAPTER 1 MAINTENANCE TESTS EtCO2 Test Tools Needed CO2 sampling line airway adapter Test Setup None Do this... 1. 2. 3. 28 Observe this... Pass/Fail The CO2 trace is on the display. o o o o On Propaq M, install the airway adapter set and sampling line in the connector at the side of the unit. Press the CO2 quick access key ( activate the CO2 trace. CO2 ) to On Propaq M, gently blow into the airway The CO2 waveform changes on the adapter set while observing the display. display. 9650-0804-01 Rev. A Functional Verification Tests IBP Test Tools Needed IBP patient simulator (with accuracy better than +/- 1 mmHg), or equivalent Setup Connect the test cables to IBP patient simulator. Do This... 1. Connect the IBP patient simulator to the Propaq P1 channel. 2. Set the IBP patient simulator to 0 mmHg. 3. On the Propaq M, press > IBP. 4. On the Propaq M, Press > P1->0<-. Observe This... Pass/Fail Display of 0/0(+/-2) in the P1 box at the bottom of the display (P1 is zeroed). o o The waveform for channel 1 is present. o o o o 5. Set the IBP patient simulator to 200 Display of 200/200(+/-5) in the P1 mmHg (or as close to 200 mmHg as your box at the bottom of the display as simulator allows). xxx/yyy where yyy=diastolic (P1 diastolic pressure is 200 (+/-5)). 6. Repeat steps 1 through 5 of this procedure for P2 and P3 channels. 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 29 CHAPTER 1 MAINTENANCE TESTS NIBP Test Tools Needed NIBP simulator, single or dual lumen hose, adult, NIBP cuff, rigid cylinder Test Setup Connect the Propaq M to the NIBP simulator using the single or dual lumen hose. Wrap the NIBP cuff around a rigid cylinder, such as a glass jar. Note: Refer to Appendix B for information on simulators and settings that you may use to assess the performance of the NIBP module. Do This... 30 1. On the Propaq M, ensure the patient mode is set to Adult. 2. Set the simulator to the 80/50 simulator preset. 3. Take a manual reading. 4. Set the simulator to the 120/80 simulator preset. 5. Take a manual reading. 6. Set the simulator to the 200/150 simulator preset. 7. Take a manual reading. Observe This... Pass/Fail Confirm that the NIBP measurement reported is within +/- 10 mmHg of the expected simulator performance. o o Confirm that the NIBP measurement reported is within +/- 10 mmHg of the expected simulator performance. o o Confirm that the NIBP measurement reported is within +/- 10 mmHg of the expected simulator performance. o o 9650-0804-01 Rev. A Functional Verification Tests Temperature Test Tools Needed IBP Temp Simulator, or equivalent Test Setup None Do this... Observe This... 1. Connect the temperature simulator to the Propaq M T1 channel. 2. On the IBP Temp Simulator, Select 98.6 The displayed temperature value is Degree F (36 Degree C) or a setting as close within 0.2 F or 0.1 C of the as possible as your simulator allows. simulator setting. 3. Repeat steps 1 and 2 of this procedure for the T2 channel. 9650-0804-01 Rev. A ZOLL Propaq M Service Manual Pass/Fail o o 31 CHAPTER 1 MAINTENANCE TESTS 32 9650-0804-01 Rev. A Chapter 2 Troubleshooting Overview This chapter contains a list of error messages that users may see if the unit is not operating properly. If the errors you encounter are not listed below, call ZOLL Medical Corporation’s Technical Service Department for further assistance. (See “Technical Service” on page 3 for contact information.) Propaq M Error Messages The following is a list of the Propaq M error messages that may appear on your display. The “Technical Action” column describes what you as a technician can do to correct the situation. Error Message Explanation Technical Action SW SHUTDOWN WARNING Indication that the battery has reached the software shutdown capacity. Charge the battery. HW SHUTDOWN Voltage threshold exceeded the minimum working threshold of the device. There is no warning. Charge the battery. 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 33 CHAPTER 2 TROUBLESHOOTING 34 Error Message Explanation Technical Action QUICK ACCESS SW 1 SHORT Quick access key 1 is stuck. Replace the front panel. QUICK ACCESS SW 2 SHORT Quick access key 2 is stuck. Replace the front panel. QUICK ACCESS SW 3 SHORT Quick access key 3 is stuck. Replace the front panel. QUICK ACCESS SW 4 SHORT Quick access key 4 is stuck. Replace the front panel. QUICK ACCESS SW 5 SHORT Quick access key 5 is stuck. Replace the front panel. QUICK ACCESS SW 6 SHORT Quick access key 6 is stuck. Replace the front panel. QUICK ACCESS SW 7 SHORT Quick access key 7 is stuck. Replace the front panel. SCREEN CYCLE SHORT Display/home key is stuck. Replace the front panel. ALARM SILENCE SHORT Alarm Silence/Reset key is stuck. Replace the front panel. NAV PAD UP SHORT Up/Clockwise Navigation key is stuck. Replace the front panel. NAV PAD SELECT SHORT Select key is stuck. Replace the front panel. NAV PAD DOWN SHORT Down/Counterclockwise Navigation key is stuck. Replace the front panel. SNAPSHOT SHORT Snapshot key is stuck. Replace the front panel. ECG DEVICE FAILURE ECG software detected a problem with the ECG data that is most likely a hardware issue. Replace the main board. TEMP DEVICE FAILURE Temp software detected a problem with the temperature data that is most likely a hardware issue. Replace the main board. TEMP PROBE1 SHORTED An A/D value was detected that indicated the probe was shorted. Replace the temperature probe or adapter cable. If problem persists, replace the right side panel. 9650-0804-01 Rev. A Propaq M Error Messages Error Message Explanation Technical Action TEMP PROBE2 SHORTED An A/D value was detected that indicated the probe was shorted. Replace the temperature probe or adapter cable. If problem persists, replace the right side panel. TEMP1 CIRCUIT FAILURE The software detected an out-of-range A/D converter. Remove probe, power cycle. If problem persists, replace main board. TEMP2 CIRCUIT FAILURE The software detected an out-of-range A/D converter. Remove probe, power cycle. If problem persists, replace main board. IBP DEVICE FAILURE IBP software detected a problem with the IBP data that is most likely a hardware issue. Replace the main board. IBP PROBE1 SHORTED An A/D value was detected that indicated the probe was shorted. Replace the IBP probe. If problem persists, replace the right side panel. IBP PROBE2 SHORTED An A/D value was detected that indicated the probe was shorted. Replace the IBP probe. If problem persists, replace the right side panel. IBP PROBE3 SHORTED An A/D value was detected that indicated the probe was shorted. Replace the IBP probe. If problem persists, replace the right side panel. IBP PROBE1 CIRCUIT FAILURE An unsupported probe was inserted or there is a circuit problem. Unplug probe, power cycle. If problem persists, replace main board. IBP PROBE2 CIRCUIT FAILURE An unsupported probe was inserted or there is a circuit problem. Unplug probe, power cycle. If problem persists, replace main board. IBP PROBE3 CIRCUIT FAILURE An unsupported probe was inserted or there is a circuit problem. Unplug probe, power cycle. If problem persists, replace main board. SPO2 DEVICE FAILURE Communication failure or device malfunction. Check SpO2 communication cables. If problem persists, replace the SpO2 module. 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 35 CHAPTER 2 TROUBLESHOOTING 36 Error Message Explanation Technical Action NIBP MONITORING FAILURE One of the following issues occurred: • A failure was reported by the NIBP module. • The two transducers are not aligned. They are either not calibrated, there is a transducer failure, or there is a kinked tube. • A calibration problem was reported by the NIBP module. If problem persists, replace the NIBP module. NIBP COMMUNICATION FAILURE There is a communication problem with the NIBP module. Ensure that the J32 connection is secure. If error persists, replace the NIBP module. NIBP CALIBRATION CHECK DUE Annual calibration check is due. Perform the NIBP Calibration Check procedure in Chapter 1, "Calibration and Calibration Checks". NIBP KINKED HOSE The cuff inflation was too rapid. There may be kinked tubing or another air obstruction. Check the external NIBP hose for kinks. If problem persists, check the routing of the NIBP tubing inside the device. NIBP MAX PRESSURE EXCEEDED Pressure limit exceeded. If problem persists, do the following: • Check the calibration via the NIBP Calibration Check procedure in Chapter 1, "Calibration and Calibration Checks". • Check the routing of the NIBP tubing inside the device for kinks or obstructions. If the NIBP module is out of calibration, replace the NIBP module. 9650-0804-01 Rev. A Propaq M Error Messages Error Message Explanation Technical Action NIBP AIR LEAK Major air leak or could not reach target pressure. Attempt to identify problems with the hose and/or cuff by doing the following: • Check the hose connection to the device. Make sure that the hose is tightly screwed onto the NIBP connector. • Ensure that the cuff is appropriately wrapped and is not too loose. • Inspect the cuff and hose for leaks. Inspect the O-ring on the NIBP hose connector. Consider replacing the cuff and/or hose. If the problem persists, perform one of the following procedures in Chapter 1, "NIBP Valve, Pump, and Tubing Integrity Tests": • NIBP Leak Test • NIBP Inflation Test Inspect internal NIBP tubing for leaks. NIBP EQUIPMENT CHECK Device is unable to obtain a reading. Check the hose and cuff connections. If problem persists, perform one or more of the following procedures outlined in Chapter 1, "NIBP Valve, Pump, and Tubing Integrity Tests": • NIBP Leak Test • NIBP Deflation Test • NIBP Inflation Test NIBP WEAK PULSE Too few pulses are detected during the reading attempt. Tighten the cuff and ensure appropriate placement. NIBP TEMP OUT OF RANGE Module temperature is out of its specified operating range. Move the device to a cooler or warmer environment. NIBP ARTIFACT Unable to determine blood pressure. Check connections; restrict patient movement. Attempt to identify and eliminate the source of artifact. If problem persists, replace the NIBP module. 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 37 CHAPTER 2 TROUBLESHOOTING 38 Error Message Explanation Technical Action NIBP NEONATAL DETECTED Device thinks a neonate cuff is connected. If no neonate cuff is connected, tubing may be damaged or kinked. Verify that neonate cuff is not connected. If problem persists, check the routing of the NIBP tubing inside the device. NIBP LOW VOLTAGE Insufficient voltage is supplied to the NIBP module. Check the module voltage in the NIBP Test screen. Inspect the unit or water ingress. If evidence of water ingress is found, allow the water to evaporate while periodically checking the module voltage. If problem persists, replace the NIBP module. SPO2 COM ERROR CODE Communication error. Check communication cables. If problem persists, replace the SpO2 module. SPO2 SENSOR FAILURE Defective sensor or sensor error. Replace the SpO2 sensor. SPO2 UNKNOWN RECOVERY NUM Recovery error. Replace the SpO2 sensor. CO2 DEVICE FAILURE Malfunction or device failure. Replace the CO2 module. CO2 COM ERROR CODE Communication failure. Check communication cables. If problem persists, replace the CO2 module. CO2 BAROMETRIC OUT OF RANGE Altitude is too high for module. Bring device into specified altitude range. If problem persists, replace the CO2 module. CO2 CAL REMINDER Calibration reminder. Calibrate the CO2 module soon. CO2 CAL REQUIRED Calibration due. Calibrate the CO2 module. CO2 CHECK FLOW Exhaust port blocked. Check for exhaust port occlusion. If problem persists, replace the CO2 module. 9650-0804-01 Rev. A Propaq M Error Messages Error Message Explanation Technical Action CO2 GAS INPUT OCCLUSION CO2 inlet blocked. Replace FilterLine®. If problem persists, check for CO2 inlet occlusion. If still persists, replace the CO2 module. CO2 MAINTENANCE REMINDER Periodic maintenance reminder. Replace CO2 module soon. CO2 MAINTENANCE REQUIRED Periodic Maintenance due. Replace CO2 module. CO2 NO FILTERLINE No filterline is detected. If FilterLine is connected and problem persists, replace FilterLine. If still persists, replace the CO2 module. CO2 CAL FAILURE Calibration failed. Retry calibration or continue with old calibration. Replace the CO2 module. 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 39 CHAPTER 2 TROUBLESHOOTING 40 9650-0804-01 Rev. A Chapter 3 Disassembly Procedures Overview This chapter provides instructions on how to disassemble and reassemble the Propaq M unit, and includes the following sections: • • • • • • • • • Required Equipment Safety Precautions Modules Handle Disassembly Main Unit Disassembly Front Enclosure Disassembly Display Disassembly NIBP and EtCO2 Disassembly Monitor Board and SpO2 Disassembly Required Equipment • • • • • • • • • • No. 1 Phillips screwdriver with torque capability No. 2 Phillips screwdriver with torque capability Exacto-knife Orange wooden stick. (Available from H.A. Stiles: 1-800-447-8537) 90° dental pick Needle nose pliers 6 mm socket wrench 26 mm socket wrench Kapton tape 3M copper adhesive tape, or equivalent 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 41 CHAPTER 3 DISASSEMBLY PROCEDURES • • • • 1/2” nut driver Large diagonal cutters Strong glue, such as Loctite 420 or equivalent Loctite needle tip dispenser Safety Precautions • Only properly trained technicians should service the unit. • Make sure you take the necessary precautions when working with static sensitive units. For example, you must wear a conductive wrist strap (which touches your skin) connected to a grounding mat and to the earth ground. Modules The Propaq M unit contains the following six (6) modules or assemblies: • • • • • • Front Enclosure Display NIBP EtCO2 (Oridion®) Monitor Board SpO2 These modules can be purchased as replacement parts from the ZOLL Technical Support Department. See Chapter 5, "Replacement Parts" for information on ordering replacement parts. 42 9650-0804-01 Rev. A Removing the Handle Removing the Handle Tools Required • #1 Phillips screwdriver with torque capability • Orange (wooden) stick Setup • This procedure should be conducted on a static mat. • Wear a wrist strap to ground during the procedure. To reinstall the handle assembly, reverse the steps. Handle Disassembly 1 Using an orange stick, lift the screw covers off the handle in two locations. screw covers 2 Remove four (4) screws (2 on each handle) and remove the handle. Note: During reassembly, torque screws to 8 in-lbs. 9650-0804-01 Rev. A screws ZOLL Propaq M Service Manual 43 Disassembling the Main Unit Tool Required • # 1 Phillips screwdriver with torque capability • orange (wooden) stick Setup • This procedure should be conducted on a static mat. • Wear a wrist strap to ground during the procedure. • Complete “Removing the Handle” on page 43 before performing this procedure. To reassemble the main unit, reverse the steps. Main Unit Disassembly 1 Place tape on the top of the unit (near the front of the display) in the illustrated area. 2 Gently place unit screen so the display screen is facing down. 3 Remove ten (10) screws: four (4) on the top, four (4) on the bottom, and two (2) in the middle in the illustrated areas. Take care to keep the two parts of the unit together. Note: During reassembly, torque screws to 6 in-lbs. 44 4 While holding the two parts of the unit together, place the unit vertically on the mat (feet down). 5 Separate the top part of the unit by creating a small gap, and remove any screws that are in the way. 9650-0804-01 Rev. A Disassembling the Main Unit 6 Disconnect the battery communication cable (yellow, orange, brown, red) connector from the monitor board. battery cable 7 Disconnect the termination board from the monitor board. 8 Disconnect the two power cable connectors (battery (black) and AUX (white)). p two power cables 9 Use an orange stick to release the tabs on either side of silver ZIF connector between the dock connector and the monitor board. Note: Release one side at a time. NIBP hoses 10 9650-0804-01 Rev. A Separate the two parts of the unit. ZOLL Propaq M Service Manual 45 11 Disconnect the NIBP tube from the rear case. NIBP tube NIBP hoses 46 9650-0804-01 Rev. A Removing the Front Enclosure Module Removing the Front Enclosure Module Tools Required • #2 Phillips screwdriver with torque capability • Orange (wooden) stick Setup • This procedure should be conducted on a static mat. • Wear a wrist strap to ground during the procedure. • Complete these procedures in the following order before performing this procedure: 1. “Removing the Handle” on page 43 2. “Disassembling the Main Unit” on page 44 To reinstall the front enclosure module, reverse the steps. Front Enclosure Disassembly 1 Remove tape from the top of the unit. 2 Separate monitor front enclosure. 3 Pivot top up with cables still connected. 4 Remove grounding screw as shown in the illustration. Note: During reassembly, torque screw to 6 in-lbs. 5 grounding screw Disconnect the front panel multi-wire cable in the area illustrated. multi-wire cable 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 47 6 48 Remove the ZIF (Zero Insertion Force) flex cable using an orange stick. 9650-0804-01 Rev. A Removing the Display Module Removing the Display Module Tools Required • #1 Phillips screwdriver with torque capability • 3M copper adhesive tape • 6mm socket wrench Setup • This procedure should be conducted on a static mat. • Wear a wrist strap to ground during the procedure. • Complete these procedures in the following order before performing this procedure: 1. “Disassembling the Main Unit” on page 44 2. “Removing the Front Enclosure Module” on page 47 To reinstall the display module, reverse the steps. Display Disassembly 1 Place the back of the unit down on the mat so that the display screen is facing up. 2 Remove the six (6) screws from the front of the casting in the areas illustrated. Note: During reassembly, torque screws to 6 in-lbs. 3 Flip the unit over and remove the screw in the area illustrated. 4 Remove the hex standoff located underneath the screw you just removed. Note: During reassembly, torque to 6 in-lbs. hex standoff 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 49 5 Flip the unit back over so the display screen is facing up. 6 Lift the casting up while pushing down on the rubber boot that runs around the edge of the LCD screen. boot 7 Remove the copper tape from the casting. Note: During reassembly, apply new copper tape for grounding. copper tape 8 Disconnect the LCD display cable connectors from the back of the LCD screen to release it. cable connectors 9 Remove the Kapton tape from the display cable. Kapton tape 50 9650-0804-01 Rev. A Removing the EtCO2 and NIBP Modules Removing the EtCO2 and NIBP Modules Tool Required • # 1 Phillips screwdriver with torque capability • orange (wooden) stick Setup • This procedure should be conducted on a static mat. • Wear a wrist strap to ground during the procedure. • Complete these procedures in the following order before performing this procedure: 1. “Removing the Handle” on page 43 2. “Disassembling the Main Unit” on page 44 3. “Removing the Front Enclosure Module” on page 47 Note: After replacing the EtCO2 and/or NIBP modules, see Chapter 4, "Resetting Life Cycle Counters" to reset the life cycle counters for the module(s) that you have replaced. To assemble the EtCO2 and/or NIBP modules, reverse the steps. EtCO2 and/or NIBP Disassembly 1 Remove the right side panel (containing temperature, IBP, and USB connectors) by removing four (4) screws from inside the unit. Note: During reassembly, torque screws to 6 in-lbs. 2 Remove three (3) screws from underneath and outside the unit. Note: During reassembly, torque screws to 6 in-lbs. 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 51 3 Disconnect multi-wire IBP cable with ferrite in the area illustrated. 4 Cut the tie wrap to the IBP cable in the area shown with the orange stick. multi-wire IBP cable Note: During reassembly, secure a new tie wrap to the IBP cable. 5 Disconnect the USB flex cable from ZIF connector in the area illustrated. 6 Lay front end of separated unit down with opened side facing up. 7 Disconnect the black EtCO2 tube connector from the air vent. 8 Remove four (4) screws in the areas illustrated to release the silver EtCO2 module. Note: During reassembly, torque screws to 6 in-lbs. 52 9650-0804-01 Rev. A Removing the EtCO2 and NIBP Modules 9 Remove five (5) screws and washers from the NIBP unit to release it. Note: During reassembly, torque screws to 6 in-lbs. 10 Cut the tie wrap to the ferrite. tie wrap 11 Remove multi-wire EtCO2 cable with ferrite. 12 Disconnect the brown SpO2 flex cable as shown. 13 Disconnect the NIBP tubing from the side panel in the area illustrated. 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 53 14 Remove the NIBP module from the unit. 15 Tilt side panel to access the EtCO2 connector and use an orange stick release the tabs and remove the EtCO2 connector. EtCo EtCO2 connector after removal 2 connector after removal EtCo2 connector before removal 16 Remove the EtCO2 module from the unit. 17 Remove three (3) screws from the outside of the left side panel in the areas illustrated. Note: During reassembly, torque screws to 6 in-lbs. 18 Remove four (4) screws from the inside top of the left side panel in the areas illustrated and carefully pull out side panel. Note: During reassembly, torque screws to 6 in-lbs. 54 19 Remove ECG ZIF connector in the area illustrated. 20 Remove the left side panel from the unit. 9650-0804-01 Rev. A Removing the Monitor Board and SpO2 Modules Removing the Monitor Board and SpO2 Modules Tool Required • # 1 Phillips screwdriver with torque capability Setup • This procedure should be conducted on a static mat. • Wear a wrist strap to ground during the procedure. • Complete these procedures in the following order before performing this procedure: 1. “Removing the Handle” on page 43 2. “Disassembling the Main Unit” on page 44 3. “Removing the Front Enclosure Module” on page 47 4. “Removing the Display Module” on page 49 5. “Removing the EtCO2 and NIBP Modules” on page 51 Note: After replacing the Monitor Board and/or SpO2 modules, see Chapter 4, "Resetting Life Cycle Counters" to reset the life cycle counter for the module. To reinstall the monitor board and/or SpO2 modules, reverse the steps. Monitor Board and/or SpO2 Disassembly 1 Remove the EtCO2 anti-conductive shield that lies on top of the unit. shield 2 Remove six (6) screws to release the monitor board in the areas illustrated. Note: During reassembly, torque screws to 6 in-lbs. 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 55 3 Lift the monitor board to expose the multi-wire LCD cable on the back side of monitor board and disconnect it. 4 Remove three (3) screws and washers from the NIBP unit. Note: During reassembly, torque screws to 6 in-lbs. 56 5 Lift the SpO2 unit straight up to disconnect it from the monitor board and remove it from the unit. 6 Lift out the monitor board. 9650-0804-01 Rev. A Chapter 4 Life Cycle Counters Overview This chapter contains instructions for setting life cycle counters on the Propaq M. The Propaq M tracks various life cycle counters for specific modules installed in the device. When replacing modules in the unit, it is important to reset the life cycle counters. Once you have reset the appropriate life cycle counter(s), see “Functional Verification Tests” on page 1-22 to perform the functional verification tests to ensure that the functions of the Propaq M unit work properly. Note: Only reset the life cycle counters for the modules that you have replaced. Resetting Life Cycle Counters NIBP On the Propaq M, do the following: 1. Press the Setup quick access key ( ). 2. Use the navigation keys to select Supervisor>Service>Diagnostic>NIBP>Cycle/Error Counts. 3. Select Reset Counters. Select Yes when prompted to confirm the reset. See “Functional Verification Tests” on page 1-22 to perform the functional verification tests. 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 57 CHAPTER 4 LIFE CYCLE COUNTERS CO2 On the Propaq M, do the following: 1. Press the Setup quick access key ( ). 2. Use the navigation keys to select Supervisor>Service>Diagnostic>CO2>Service Codes. 3. Select Reset CRC Counter. Select Yes when prompted to confirm the reset. See “Functional Verification Tests” on page 1-22 to perform the functional verification tests. SpO2 On the Propaq M, do the following: 1. Press the Setup quick access key ( ). 2. Use the navigation keys to select Supervisor>Service>Diagnostic>SpO2>Error Counts. 3. Select Reset CRC Counter. Select Yes when prompted to confirm the reset. See “Functional Verification Tests” on page 1-22 to perform the functional verification tests. 58 9650-0804-01 Rev. A Chapter 5 Replacement Parts Overview This section contains a listing of the replacement parts available for the ZOLL Propaq M devices. Replacement parts may be ordered through an authorized ZOLL distributor or directly from ZOLL Medical Corporation. The prices for parts are available from ZOLL Medical Corporation’s Technical Service Department. When ordering parts, please provide the following information: • Propaq M device model and serial number • Field replaceable part number • Description of the replacement assembly To order by mail from ZOLL Medical Corporation, address your request to: ZOLL Medical Corporation 269 Mill Road Chelmsford, MA. 01824-4105 Attention: Technical Service Department 1-978-421-9655; 1-800-348-9011; Fax: 1-978-421-0010 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 59 CHAPTER 5 REPLACEMENT PARTS Replacement Parts 60 PART NUMBER QUANTITY DESCRIPTION 705519 1 Handle Top 705517 1 Handle Bottom 705510 4 Screw 0162-0263 4 Screw Mount 705523 1 Left Cap, Handle 705524 1 Right Cap, Handle 1017-0005-01 1 Front Panel Assembly 403889 1 Panel I/O Left 402359 1 Panel I/O Right 705099-99 1 Back Housing 708494-99 1 Middle Housing 9301-0225 1 Dock Connector Assembly 403888 1 Power Assembly Cable 403871 1 Assy Battery Connection 704992 1 Cover, Filter Recess 1017-0160-01 1 Assy, Filter, NIBP 7772-0002-01 1 Front Enclosure Assembly 7772-0003-01 1 Display Assembly 7772-0004-01 1 NIBP Assembly 9650-0804-01 Rev. A Replacement Parts PART NUMBER QUANTITY DESCRIPTION 7772-0005-01 1 Oridion Assembly 7772-0006-01 1 Monitor Board Assembly 7772-0009-01 1 SpO2 Assembly 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 61 CHAPTER 5 REPLACEMENT PARTS 62 9650-0804-01 Rev. A Chapter 6 Functional Description Overview This chapter contains functional descriptions of the components contained in the Propaq M and the Propaq M options. Circuit Distribution The Propaq M unit consists of one key PCB assembly, the Monitor Board, as well as a few modules and assemblies: the Front Panel Keypad assembly, Status LCD Board, Dock Connector Board, and Display. The NIBP, CO2, and SpO2 circuitry reside on modules that connect to the Monitor Board. Monitor Board The Monitor board integrates the analog circuitry and interface circuitry for patient parameters, a digital processing section as well as user interface controls, audio control, and power circuitry for the entire system and charging circuitry for the battery. The Propaq M system relies on a centralized dual processor engine for its computing needs. The Main Processor (MP) serves as the primary user interface engine and provides connectivity needs, while the Patient Processor (PP) controls the patient monitoring function. An additional power controller micro-controller (PC) controls the power sequencing, and battery/charger interface. 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 63 CHAPTER 6 FUNCTIONAL DESCRIPTION Main Processor (MP) The MP section controls the user interface, connectivity needs, as well as data logging, printing, and general system control. It consists of the CPU, program memory Flash and SDRAM, Communication with modules/circuits: USB Client, USB Host, Debug Ports (JTAG,Serial), Storage memory for 24 hour disclosure data, Internal VGA display and interface circuit, LED indicators, Key Pad, and Audio circuit. The MP also controls the real-time clock and interface to the power controller processor, battery and charger. Patient Processor (PP) The Patient processor circuitry supports the data acquisition, signal processing and conditioning, analysis and control algorithms required for the physiological sensors. It consists of the processor, program memory Flash and SDRAM as well as interface circuitry to physiological sensor modules/circuits. Power Controller (PC) The Power Controller (PC) micro-controller controls the power sequencing to turn the device on and off when the power switch is pressed. It also communicates to the battery charger and battery via a serial SPI bus. Additionally, the PC controls the Status LCD and communicates battery and charger status to the MP. ECG 3/5 or 12 Lead Circuitry Propaq M supports 3/5 lead and 12 lead ECG acquisition. Analog circuitry provides signal conditioned data through an A/D converter to the PP. All of the signal processing, lead derivation, fault detection is performed by the PP. The ECG circuitry utilizes a CPLD for control of analog circuitry and transmission of data to the PP across an isolation barrier. A common connector is used to receive 3/5 Lead ECG cables with a 12 Lead ECG extension. The ECG signals from the external connector on the left side panel are connected to the monitor board through a flex cable to J28. Impedance Respiration Propaq M provides the circuitry for impedance respiration measurements in 3/5 and 12 lead configurations. This circuitry provides a low-current 72kHz AC signal across leads I and II of the ECG cable. The signal is passed through a synchronous demodulator and decoded by the PP through the ECG CPLD. Blood Pressure NIBP The Propaq M NIBP circuitry resided on module that connects to the Monitor board through J32. The PP communicates to the NIBP module via a bi-directional, serial bus. The NIBP module supports both dual lumen and single lumen cuffs. The NIBP pump and valve hoses are connected to the cuff connector on the left side panel and to the filter on the rear enclosure. The pump and valve are connected to the NIBP module by short, 2-wire cables. Invasive Blood Pressure (IBP) Propaq M supports up to 3 IBP measurement channels. The IBP circuitry supports AAMI BP-22 transducers (5uV/V/mmHg). The PP communicates directly to the IBP ADC over an isolated serial bus through the FPGA. The IBP probes connect to the monitor board through the IBP/Temp wire harness which connects to J33 of the Monitor board. 64 9650-0804-01 Rev. A Overview SPO2 Module Propaq M supports the Nellcor NELL-3 OEM Module that mounts to the Monitor board and communicates through J36 and J40. The SpO2 module communicates across an isolation barrier using a UART on the PP. Signals from the probe are routed to the SpO2 module through a flex cable that connects to J41 of the Monitor board. End tidal CO2 (CO2) Propaq M supports an Oridion Microstream® CO2 module. The CO2 module mounts to the Monitor board and communicates to the board through a cable connected to J50. Serial communications from the monitor board is implemented via a UART on the PP. The CO2 module obtains gas samples from the sampling lines through tubing and a 3-wire cable connected to the left side panel. Thermometry Propaq M supports two simultaneous temperature measurements. YSI400/YSI700 series probes are used to make temperature measurements. Data is communicated to the PP from the Temperature ADC via and isolated SPI bus through the FPGA. The Temperature probes connect to the monitor board through the IBP/Temp wire harness which connects to J33 of the Monitor board. Power Circuitry, Battery Charger, DC-DC converters Power circuitry for all subsystems reside on the Monitor Board. Auxiliary Power and Battery Power are automatically switched to provide constant current, the unit draws current from auxiliary power when present. There is a smart battery charging circuit that will charge the battery when Auxiliary power is present. Switching mode DC-DC converters are utilized to make internal 6V, 5V, 3.3V, 1.8V and processor core voltages. Regulators are used to provide regulated supply voltages with low dropout for low current consumption circuits. Each of the isolated modules, Temp/IBP, ECG, SpO2 have independent power supplies. Isolated power supplies are designed for isolating Patient Applied Parts. The MP via the FPGA GPIO has the ability to shut down voltage rails or power to individual patient parameters. Power from the battery connects to the Monitor board through J29. Auxiliary power connects to the Monitor board through J31. USB Host Port Propaq M Monitor Board incorporates one USB Host ver 1.1 port. The port uses the USB controller built into the PXA270 Main processor. Full speed of 12 Mbps and Low speed 1.5Mbps are supported. The Host port supports a USB flash memory stick for data export. The USB host connector is in the right side panel and connects to the Monitor board through J44. Lithium Ion Battery The portable Propaq M device is powered by a removable Lithium Ion battery pack. This battery pack incorporates protection circuitry and "smart battery" circuitry. The battery power is routed from the 2-pin connector on the rear of the device to J29 of the Monitor board. The Power Controller communicates to the smart circuitry on the battery through the 4 spring contacts connected to J34 on the Monitor board. 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 65 CHAPTER 6 FUNCTIONAL DESCRIPTION 66 9650-0804-01 Rev. A Appendix A Overview This appendix includes the following diagrams: • Propaq M Electrical Hardware Interconnect Diagram • Propaq M Signal and Power Interconnect Schematic 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 67 Propaq M Electrical Hardware Interconnect Diagram 68 9650-0804-01 Rev. A Propaq M Signal and Power Interconnect Schematic Propaq M Signal and Power Interconnect Schematic 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 69 70 9650-0804-01 Rev. A Appendix B Overview This appendix includes simulators and settings that may be used to assess the performance of the NIBP module. Readings should be obtained within +/- 10 mmHg of the expected measurement result. The following simulators are used in this chapter: • • • • Bio-Tek Instruments BP Pump Bio-Tek Instruments BP Pump2 DNI Nevada CuffLink Clinical Dynamics Smart Arm NIBP Simulator Performance FastBP A dual lumen hose is required for FastBP.When you use FastBP, the reading is obtained during cuff inflation. StepBP StepBP is compatible with both single and dual lumen hoses.When you use StepBP, the reading is obtained during step deflation. 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 71 Bio-Tek Instruments BP Pump Adult/Pediatric Mode FastBP StepBP Simulator Setting Expected Systolic Expected Diastolic Expected Systolic Expected Diastolic 200/150 198 151 200 149 120/80 120 83 116 84 80/50 83 54 77 53 Neonate Mode NeoBP Simulator Setting Expected Systolic Expected Diastolic 60/30 56 26 35/15 31 12 Bio-Tek Instruments BP Pump2 Adult/Pediatric Mode FastBP StepBP Simulator Setting Expected Systolic Expected Diastolic Expected Systolic Expected Diastolic 200/150 202 157 201 146 120/80 118 80 116 82 80/50 86 51 77 55 Neonate Mode NeoBP Simulator Setting Expected Systolic Expected Diastolic 80/50 78 46 60/30 57 31 35/15 31 12 72 9650-0804-01 Rev. A Overview DNI Nevada CuffLink Adult/Pediatric Mode FastBP StepBP Simulator Setting Expected Systolic Expected Diastolic Expected Systolic Expected Diastolic 200/150 210 152 201 138 120/80 116 77 124 80 80/50 87 49 90 50 Clinical Dynamics Smart Arm Adult/Pediatric Mode FastBP StepBP Simulator Setting Expected Systolic Expected Diastolic Expected Systolic Expected Diastolic 200/150 192 152 194 136 120/80 124 79 122 80 80/50 85 42 80 49 Neonate Mode NeoBP Simulator Setting Expected Systolic Expected Diastolic 80/50 77 48 60/30 57 32 35/15 31 13 9650-0804-01 Rev. A ZOLL Propaq M Service Manual 73 74 9650-0804-01 Rev. A
advertisement
Related manuals
advertisement