Nortel Contivity 600 Getting Started
PDF
Dokument
Reklama
Reklama
Version 2.63
Part No. 311862-A Rev 00
November 2000
600 Technology Park Drive
Billerica, MA 01821-4130
Getting Started with the
Contivity 600
2
Copyright © 2000 Nortel Networks
All rights reserved. November 2000.
The information in this document is subject to change without notice. The statements, configurations, technical data,
and recommendations in this document are believed to be accurate and reliable, but are presented without express or
implied warranty. Users must take full responsibility for their applications of any products specified in this document.
The information in this document is proprietary to Nortel Networks NA Inc.
The software described in this document is furnished under a license agreement and may be used only in accordance
with the terms of that license. The software license agreement is included in this document.
Trademarks
NORTEL NETWORKS is a trademark of Nortel Networks.
Bay Networks, Nortel Networks Contivity 1600, Contivity, Extranet Ready, Personal Extranets, and Infrastructure for
Extranets are trademarks of Nortel Networks.
Microsoft, MS, MS-DOS, Win32, Windows, and Windows NT are registered trademarks of Microsoft Corporation.
All other trademarks and registered trademarks are the property of their respective owners.
Statement of Conditions
In the interest of improving internal design, operational function, and/or reliability, Nortel Networks NA Inc. reserves
the right to make changes to the products described in this document without notice.
Nortel Networks NA Inc. does not assume any liability that may occur due to the use or application of the product(s)
or circuit layout(s) described herein.
Portions of the code in this software product may be Copyright © 1988, Regents of the University of California. All
rights reserved. Redistribution and use in source and binary forms of such portions are permitted, provided that the
above copyright notice and this paragraph are duplicated in all such forms and that any documentation, advertising
materials, and other materials related to such distribution and use acknowledge that such portions of the software were
developed by the University of California, Berkeley. The name of the University may not be used to endorse or
promote products derived from such portions of the software without specific prior written permission.
SUCH PORTIONS OF THE SOFTWARE ARE PROVIDED “AS IS” AND WITHOUT ANY EXPRESS OR
IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
In addition, the program and information contained herein are licensed only pursuant to a license agreement that
contains restrictions on use and disclosure (that may incorporate by reference certain limitations and notices imposed
by third parties).
Federal Communications Commission (FCC) Compliance Notice: Radio Frequency Notice
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio
frequency energy. If it is not installed and used in accordance with the instruction manual, it may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference, in which case users will be required to take whatever measures may be necessary to correct the
interference at their own expense.
EN 55 022 Statement
This is to certify that the Nortel Networks Contivity is shielded against the generation of radio interference in
accordance with the application of Council Directive 89/336/EEC, Article 4a. Conformity is declared by the
application of EN 55 022 Class A (CISPR 22).
311862-A Rev 00
3
Warning: This is a Class A product. In a domestic environment, this product may cause radio interference, in which
case, the user may be required to take appropriate measures.
Achtung: Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes
Rundfunkstörungen auftreten, in welchen Fällen der Benutzer für entsprechende Gegenmaßnahmen verantwortlich
ist.
Attention: Ceci est un produit de Classe A. Dans un environnement domestique, ce produit risque de créer des
interférences radioélectriques, il appartiendra alors à l’utilisateur de prendre les mesures spécifiques appropriées.
EC Declaration of Conformity
This product conforms (or these products conform) to the provisions of Council Directive 89/336/EEC and
73/23/EEC. Go to http://libra2.corpwest.baynetworks.com/cgi-bin/ndCGI.exe/DocView/ on the Nortel Networks
World Wide Web site for a copy of the Declaration of Conformity.
Voluntary Control Council for Interference (VCCI) Statement
Canadian Department of Communications Radio Interference Regulations
This digital apparatus (Contivity) does not exceed the Class A limits for radio-noise emissions from digital apparatus
as set out in the Radio Interference Regulations of the Canadian Department of Communications.
Règlement sur le brouillage radioélectrique du ministère des Communications
Cet appareil numérique (Contivity) respecte les limites de bruits radioélectriques visant les appareils numériques de
classe A prescrites dans le Règlement sur le brouillage radioélectrique du ministère des Communications du Canada.
Nortel Networks NA Inc. Software License Agreement
NOTICE: Please carefully read this license agreement before copying or using the accompanying software or
installing the hardware unit with pre-enabled software (each of which is referred to as “Software” in this Agreement).
BY COPYING OR USING THE SOFTWARE, YOU ACCEPT ALL OF THE TERMS AND CONDITIONS OF
THIS LICENSE AGREEMENT. THE TERMS EXPRESSED IN THIS AGREEMENT ARE THE ONLY TERMS
UNDER WHICH NORTEL NETWORKS WILL PERMIT YOU TO USE THE SOFTWARE. If you do not accept
these terms and conditions, return the product, unused and in the original shipping container, within 30 days of
purchase to obtain a credit for the full purchase price.
1. License grant. Nortel Networks NA Inc. (“Nortel Networks”) grants the end user of the Software (“Licensee”) a
personal, nonexclusive, nontransferable license: a) to use the Software either on a single computer or, if applicable, on
a single authorized device identified by host ID, for which it was originally acquired; b) to copy the Software solely
for backup purposes in support of authorized use of the Software; and c) to use and copy the associated user manual
solely in support of authorized use of the Software by Licensee. This license applies to the Software only and does not
extend to Nortel Networks Agent software or other Nortel Networks software products. Nortel Networks Agent
software or other Nortel Networks software products are licensed for use under the terms of the applicable Nortel
Getting Started with the Contivity 600
4
Networks NA Inc. Software License Agreement that accompanies such software and upon payment by the end user of
the applicable license fees for such software.
2. Restrictions on use; reservation of rights. The Software and user manuals are protected under copyright laws.
Nortel Networks and/or its licensors retain all title and ownership in both the Software and user manuals, including
any revisions made by Nortel Networks or its licensors. The copyright notice must be reproduced and included with
any copy of any portion of the Software or user manuals. Licensee may not modify, translate, decompile, disassemble,
use for any competitive analysis, reverse engineer, distribute, or create derivative works from the Software or user
manuals or any copy, in whole or in part. Except as expressly provided in this Agreement, Licensee may not copy or
transfer the Software or user manuals, in whole or in part. The Software and user manuals embody Nortel Networks’
and its licensors’ confidential and proprietary intellectual property. Licensee shall not sublicense, assign, or otherwise
disclose to any third party the Software, or any information about the operation, design, performance, or
implementation of the Software and user manuals that is confidential to Nortel Networks and its licensors; however,
Licensee may grant permission to its consultants, subcontractors, and agents to use the Software at Licensee’s facility,
provided they have agreed to use the Software only in accordance with the terms of this license.
3. Limited warranty. Nortel Networks warrants each item of Software, as delivered by Nortel Networks and properly
installed and operated on Nortel Networks hardware or other equipment it is originally licensed for, to function
substantially as described in its accompanying user manual during its warranty period, which begins on the date
Software is first shipped to Licensee. If any item of Software fails to so function during its warranty period, as the sole
remedy Nortel Networks will at its discretion provide a suitable fix, patch, or workaround for the problem that may be
included in a future Software release. Nortel Networks further warrants to Licensee that the media on which the
Software is provided will be free from defects in materials and workmanship under normal use for a period of 90 days
from the date Software is first shipped to Licensee. Nortel Networks will replace defective media at no charge if it is
returned to Nortel Networks during the warranty period along with proof of the date of shipment. This warranty does
not apply if the media has been damaged as a result of accident, misuse, or abuse. The Licensee assumes all
responsibility for selection of the Software to achieve Licensee’s intended results and for the installation, use, and
results obtained from the Software. Nortel Networks does not warrant a) that the functions contained in the software
will meet the Licensee’s requirements, b) that the Software will operate in the hardware or software combinations that
the Licensee may select, c) that the operation of the Software will be uninterrupted or error free, or d) that all defects
in the operation of the Software will be corrected. Nortel Networks is not obligated to remedy any Software defect
that cannot be reproduced with the latest Software release. These warranties do not apply to the Software if it has been
(i) altered, except by Nortel Networks or in accordance with its instructions; (ii) used in conjunction with another
vendor’s product, resulting in the defect; or (iii) damaged by improper environment, abuse, misuse, accident, or
negligence. THE FOREGOING WARRANTIES AND LIMITATIONS ARE EXCLUSIVE REMEDIES AND ARE
IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION
ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Licensee is
responsible for the security of its own data and information and for maintaining adequate procedures apart from the
Software to reconstruct lost or altered files, data, or programs.
4. Limitation of liability. IN NO EVENT WILL NORTEL NETWORKS OR ITS LICENSORS BE LIABLE FOR
ANY COST OF SUBSTITUTE PROCUREMENT; SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL
DAMAGES; OR ANY DAMAGES RESULTING FROM INACCURATE OR LOST DATA OR LOSS OF USE OR
PROFITS ARISING OUT OF OR IN CONNECTION WITH THE PERFORMANCE OF THE SOFTWARE, EVEN
IF NORTEL NETWORKS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN NO EVENT
SHALL THE LIABILITY OF NORTEL NETWORKS RELATING TO THE SOFTWARE OR THIS AGREEMENT
EXCEED THE PRICE PAID TO NORTEL NETWORKS FOR THE SOFTWARE LICENSE.
5. Government licensees. This provision applies to all Software and documentation acquired directly or indirectly by
or on behalf of the United States Government. The Software and documentation are commercial products, licensed on
the open market at market prices, and were developed entirely at private expense and without the use of any U.S.
Government funds. The license to the U.S. Government is granted only with restricted rights, and use, duplication, or
disclosure by the U.S. Government is subject to the restrictions set forth in subparagraph (c)(1) of the Commercial
Computer Software––Restricted Rights clause of FAR 52.227-19 and the limitations set out in this license for civilian
agencies, and subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause of DFARS
252.227-7013, for agencies of the Department of Defense or their successors, whichever is applicable.
311862-A Rev 00
5
6. Use of software in the European Community. This provision applies to all Software acquired for use within the
European Community. If Licensee uses the Software within a country in the European Community, the Software
Directive enacted by the Council of European Communities Directive dated 14 May, 1991, will apply to the
examination of the Software to facilitate interoperability. Licensee agrees to notify Nortel Networks of any such
intended examination of the Software and may procure support and assistance from Nortel Networks.
7. Term and termination. This license is effective until terminated; however, all of the restrictions with respect to
Nortel Networks’ copyright in the Software and user manuals will cease being effective at the date of expiration of the
Nortel Networks copyright; those restrictions relating to use and disclosure of Nortel Networks’ confidential
information shall continue in effect. Licensee may terminate this license at any time. The license will automatically
terminate if Licensee fails to comply with any of the terms and conditions of the license. Upon termination for any
reason, Licensee will immediately destroy or return to Nortel Networks the Software, user manuals, and all copies.
Nortel Networks is not liable to Licensee for damages in any form solely by reason of the termination of this license.
8. Export and re-export. Licensee agrees not to export, directly or indirectly, the Software or related technical data or
information without first obtaining any required export licenses or other governmental approvals. Without limiting the
foregoing, Licensee, on behalf of itself and its subsidiaries and affiliates, agrees that it will not, without first obtaining
all export licenses and approvals required by the U.S. Government: (i) export, re-export, transfer, or divert any such
Software or technical data, or any direct product thereof, to any country to which such exports or re-exports are
restricted or embargoed under United States export control laws and regulations, or to any national or resident of such
restricted or embargoed countries; or (ii) provide the Software or related technical data or information to any military
end user or for any military end use, including the design, development, or production of any chemical, nuclear, or
biological weapons.
9. General. If any provision of this Agreement is held to be invalid or unenforceable by a court of competent
jurisdiction, the remainder of the provisions of this Agreement shall remain in full force and effect. This Agreement
will be governed by the laws of the state of California.
Should you have any questions concerning this Agreement, contact Nortel Networks, 4401 Great America Parkway,
P.O. Box 58185, Santa Clara, California 95054-8185.
LICENSEE ACKNOWLEDGES THAT LICENSEE HAS READ THIS AGREEMENT, UNDERSTANDS IT, AND
AGREES TO BE BOUND BY ITS TERMS AND CONDITIONS. LICENSEE FURTHER AGREES THAT THIS
AGREEMENT IS THE ENTIRE AND EXCLUSIVE AGREEMENT BETWEEN NORTEL NETWORKS AND
LICENSEE, WHICH SUPERSEDES ALL PRIOR ORAL AND WRITTEN AGREEMENTS AND
COMMUNICATIONS BETWEEN THE PARTIES PERTAINING TO THE SUBJECT MATTER OF THIS
AGREEMENT. NO DIFFERENT OR ADDITIONAL TERMS WILL BE ENFORCEABLE AGAINST NORTEL
NETWORKS UNLESS NORTEL NETWORKS GIVES ITS EXPRESS WRITTEN CONSENT, INCLUDING AN
EXPRESS WAIVER OF THE TERMS OF THIS AGREEMENT.
Getting Started with the Contivity 600
6
311862-A Rev 00
7
Contents
Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Related publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Text . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Acronyms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Hard-copy technical manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
User interface help button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
How to get help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Chapter 1
Introducing the Contivity 600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Chapter 2
Cabling and LEDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Connecting the cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Power cord requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Current rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Wall outlet connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Power supply connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Cord length and flexibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
LAN interface connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Single WAN interface V.35 or X.21 (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
T1 CSU/DSU WAN interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Serial interface cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Understanding the LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Front panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
LAN LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
V.35/X.21 single LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Getting Started with the Contivity 600
8 Contents
T1 CSU/DSU LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Public LAN LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Chapter 3
Changing Hardware Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Removing the rear of the chassis to access the system . . . . . . . . . . . . . . . . . . . . . . . 40
Chapter 4
Using Recovery Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Chapter 5
Assigning a System Identity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Startup configuration requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Management IP address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Subnet mask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Default gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
IP address configuration utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Running the IP configuration utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Serial interface configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Prerequisites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Appendix A
Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
311862-A Rev 00
9
Figures
Figure 1
Front view of the Contivity 600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Figure 2
Back view of the Contivity 600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Figure 3
10/100BASE-TX pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Figure 4
Single V.35/X.21 WAN interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Figure 5
T1 CSU/DSU interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Figure 6
Front panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Figure 7
LAN Port LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Figure 8
Single V.35/X.21 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Figure 9
T1 CSU/DSU LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Figure 10
10/100BASE-TX LAN LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Figure 11
Removing the bottom screws . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Figure 12
Removing the system from the casing . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Figure 13
Removing the chassis from the rear of the Contivity . . . . . . . . . . . . . . . . 42
Figure 14
Photographic view of the Contivity 600 system board . . . . . . . . . . . . . . . 42
Figure 15
Simplified drawing of the Contivity 600 mother board . . . . . . . . . . . . . . . 43
Figure 16
Removing the bottom screws . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Figure 17
Removing the chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Figure 18
Removing a blank PCI bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Figure 19
Removing a blank option card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Figure 20
Blank option card after screw removed . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Figure 21
Replacing screw at right end of the PCI card . . . . . . . . . . . . . . . . . . . . . . 49
Figure 22
Replacing chassis in casing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Figure 23
Recovery diskette display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Figure 24
The ExtNepIP.exe icon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Figure 25
The serial number search display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Figure 26
Extranet address configuration utility display . . . . . . . . . . . . . . . . . . . . . . 60
Getting Started with the Contivity 600
10 Figures
311862-A Rev 00
11
Tables
Table 1
Components and accessories of a Contivity 600 . . . . . . . . . . . . . . . . . . . 21
Table 2
DB28S-to-V.35 cable pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Table 3
DB28S-to-X.21 cable pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Table 4
T1 CSU/DSU cable pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Table 5
Multiple DB9 and DB25 connector pinouts . . . . . . . . . . . . . . . . . . . . . . . . 32
Table 6
LAN port LED indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Table 7
Single V.35/X.21 LED indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Table 8
T1 CSU/DSU LED indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Table 9
10/100BASE-TX LAN LED card indicators . . . . . . . . . . . . . . . . . . . . . . . . 37
Table 10
Initial configuration options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Table 11
Physical specifications and operating environment . . . . . . . . . . . . . . . . . 65
Getting Started with the Contivity 600
12 Tables
311862-A Rev 00
13
Preface
This guide takes you through the necessary tasks to get your Nortel NetworksTM
Contivity 600TM up and running. Topics include:
•
•
•
•
Introducing the Contivity
Opening the Contivity
Accessing the PCI inserts
Changing PCI cards
Complete details for configuring and monitoring the Switch are in
Managing the Contivity Switch.
Conventions
This guide refers to the Contivity as the Contivity 600, the 600, the Switch, or the
Contivity. It assumes that you are familiar with Web browsers and their general
operation.
Documentation
This document uses the following conventions to distinguish among notes of
varying importance.
Note: Take notice. Notes contain helpful suggestions or references to
materials contained in this document.
Getting Started with the Contivity 600
14 Preface
Caution: Be careful. In this situation, you might do something that
could result in damage to the equipment or loss of data.
Warning: Danger. You are in a situation that could cause bodily injury.
Before working on equipment, beware of the hazards involved with
electrical circuitry and standard practices for preventing accidents, such
as disconnecting equipment from its power source.
Related publications
The following list shows the associated documentation that you will need to
configure and manage the Switch and describes the document’s objectives.
•
•
311862-A Rev 00
Release Notes provide the latest information, including known problems,
workarounds, and special considerations.
Managing the Contivity Extranet Switch (included on the CD) provides
complete details to configure, monitor, and troubleshoot the Switch.
Preface 15
Text
This guide uses the following text conventions:
angle brackets (< >)
Indicate that you choose the text to enter based on the
description inside the brackets. Do not type the
brackets when entering the command.
Example: If the command syntax is
ping <ip_address>, you enter
ping 192.32.10.12
bold Courier text
Indicates command names, options, and text that you
need to enter.
Example: Use the dinfo command.
Example: Enter show ip {alerts|routes}.
italic text
Indicates new terms, book titles, and variables in
command syntax descriptions. Where a variable is two
or more words, the words are connected by an
underscore.
Example: If the command syntax is
show at <valid_route>, valid_route is one
variable and you substitute one value for it.
plain Courier
text
Indicates command syntax and system output, for
example, prompts and system messages.
Example: Set Trap Monitor Filters
separator ( -> )
Shows menu paths.
Example: Protocols -> IP identifies the IP option on the
Protocols menu.
Acronyms
This guide uses the following acronyms:
AUI
attachment unit interface
BootP
Bootstrap Protocol
BRI
basic rate interface
Getting Started with the Contivity 600
16 Preface
CSMA/CD
carrier sense multiple access/collision detection
DLCMI
Data Link Control Management Interface
HDLC
High-level Data Link Control
IP
Internet Protocol
ISDN
Integrated Services Digital Network
ISO
International Organization for Standardization
ITU-T
International Telecommunication
Union-Telecommunication Standardization Sector
(formerly CCITT)
MAU
media access unit
MDI-X
medium dependent interface crossover
NBMA
nonbroadcast multi-access
OSPF
Open Shortest Path First
PPP
Point-to-Point Protocol
SMDS
Switched Multimegabit Data Service
SNMP
Simple Network Management Protocol
STP
shielded twisted pair
TPE
twisted pair Ethernet
Hard-copy technical manuals
You can print selected technical manuals and release notes free, directly from the
Internet. Go to the www25.nortelnetworks.com/library/tpubs/ URL. Find the
product for which you need documentation. Then locate the specific category and
model or version for your hardware or software product. Use Adobe Acrobat
Reader to open the manuals and release notes, search for the sections you need,
and print them on most standard printers. Go to Adobe Systems at the
www.adobe.com URL to download a free copy of the Adobe Acrobat Reader.
You can purchase selected documentation sets, CDs, and technical publications
through the Internet at the www1.fatbrain.com/documentation/nortel/ URL.
311862-A Rev 00
Preface 17
User interface help button
Click the Help button that is located in the upper right corner of displays to learn
about fields on a given page. Where appropriate, the information provides cause
and effect of an action; otherwise, it might offer troubleshooting information.
How to get help
If you purchased a service contract for your Nortel Networks product from a
distributor or authorized reseller, contact the technical support staff for that
distributor or reseller for assistance.
If you purchased a Nortel Networks service program, contact one of the following
Nortel Networks Technical Solutions Centers:
Technical Solutions Center
Telephone
EMEA
(33) (4) 92-966-968
North America
(800) 2LANWAN or (800) 252-6926
Asia Pacific
(61) (2) 9927-8800
China
(800) 810-5000
An Express Routing Code (ERC) is available for many Nortel Networks products
and services. When you use an ERC, your call is routed to a technical support
person who specializes in supporting that product or service. To locate an ERC for
your product or service, go to the www12.nortelnetworks.com/ URL and click
ERC at the bottom of the page.
Getting Started with the Contivity 600
18 Preface
311862-A Rev 00
19
Chapter 1
Introducing the Contivity 600
The Nortel Networks Contivity 600 provides scalable, secure, manageable
extranet access for up to 30 simultaneous users across the Public Data Network
(PDN).
The Contivity’s features include the most popular tunneling protocols: IP Security
(IPsec), Point-to-Point Tunneling Protocol (PPTP), Layer 2 Forwarding Tunneling
Protocol (L2TP), and Layer 2 Forwarding (L2F). IPsec uses digital certificates,
password-based keys, and tokens for authentication; PPTP, L2TP, and L2F use
Challenge Handshake Authentication Protocol (CHAP) or Password
Authentication Protocol (PAP) for authentication. The PPTP and L2TP
implementations for the Contivity support MS-CHAP authentication with 56- to
128-bit key encryption.
The Contivity provides more security than traditional remote access schemes due
to the combination of authorization, authentication, privacy, and access control on
a per user basis. Additionally, the IPsec protocol and related Internet Security
Association and Contivity Key Management Protocol (ISACKMP) and Oakley
key establishment protocol support further enhance the security offering.
For authentication and access control, the Contivity supports an internal or
external Lightweight Directory Access Protocol (LDAP) server, and external
Remote Authentication Dial-In User Service (RADIUS) servers. To restrict
access, the Contivity uses packet filtering based on Protocol ID, Direction, Source
and Destination IP addresses, Source and Destination Ports, and TCP connection
establishment.
The unique quality of service (QoS) mechanisms include call admission and
packet forwarding priorities, and support for Resource ReSerVation Protocol
(RSVP).
Getting Started with the Contivity 600
20 Chapter 1 Introducing the Contivity 600
Figure 1 shows the front view of the Contivity 600.
Figure 1 Front view of the Contivity 600
311862-A Rev 00
Chapter 1 Introducing the Contivity 600 21
The HTML and Java Web management interface allows different Contivity
administrators to have different access rights, including configuration, status, and
monitoring. The Contivity offers RADIUS accounting support and extensive
logging, including events, system, configuration, and security logs. Table 1 lists
all of the components and accessories of the Contivity 600. If for any reason you
have not received all of the materials listed, contact Nortel Networks Customer
Service.
Table 1 Components and accessories of a Contivity 600
Description
Quantity
Contivity 600
1
Power cord (ordered separately)
Molded serial cable DB9/DB25-to-DB9/DB25
1
Contivity CD
1
IP Address Configuration Utility diskette
1
Getting Started with the Contivity 600 (this book)
1
Release Notes
1
AC to DC external power supply
1
Getting Started with the Contivity 600
22 Chapter 1 Introducing the Contivity 600
311862-A Rev 00
23
Chapter 2
Cabling and LEDS
This chapter provides the following information:
•
•
•
•
Connecting power
LAN/WAN connections to:
— 10/100BASE-TX LAN interface
— Single V.35 interface
— Single X.21 interface
— T1 CSU/DSU interface
Serial interface connection
Understanding the LEDs
Caution: Cabling for all WAN, LAN, and serial connections are not to be
routed outside the building environment.
Getting Started with the Contivity 600
24 Chapter 2 Cabling and LEDS
Connecting the cables
Use the following procedure to connect the Contivity’s cables.
Warning: Connect the LAN/WAN, serial port, and DC power cables
before connecting the AC cord to the power supply and to an AC power
source.
1
Connect the 10/100BASE-TX LAN RJ-45 connector to the Contivity and all
other LAN/WAN connections. Figure 2 shows the back of the Contivity.
Figure 2 Back view of the Contivity 600
I/O EXPANSION BAY
CONSOLE
LAN 1
FD
LAN 0
RC
DC INPUT
+12V-1.7A
-12V-0.1A
+5V-10A
75W MAX
CS60002A
311862-A Rev 00
Chapter 2 Cabling and LEDS 25
Power cord requirements
Note: LAN 0, LAN 1, and the FD and RC access openings are described
later in this section.
Warning: Do not modify or use the AC power cord if it is not the exact
type that is required for your power outlet.
Caution: You should protect your Switch by plugging it into a
surge suppressor.
Current rating
The power cord must be rated for the available AC voltage, and must have a
current rating that is at least 125 percent of the Contivity’s current rating (refer to
Appendix A).
Wall outlet connector
The power cord must terminate in a male plug with appropriate grounding. The
power cord must have certification marks from an acceptable regional agency.
Power supply connector
The connector that you plug into the Contivity power supply AC receptacle must
be an IEC 320, Sheet C13 female.
Cord length and flexibility
The power cord must be less than 4.5 meters (14.7 feet) long, and it must be a
flexible HAR (harmonized) cord or VDE-certified cordage to comply with the
Contivity’s safety certifications.
Getting Started with the Contivity 600
26 Chapter 2 Cabling and LEDS
LAN interface connections
The Contivity has two LANs built in. LAN0 is the Private LAN and is also the
LAN to use for Web management. LAN1 defaults to a Public LAN. The Contivity
software refers to the LAN1 port as Slot 1, interface 1.
At least one LAN interface connection is for Web management.
100BASE-TX connections require Category 5, twisted-pair wire. The
100BASE-TX specification supports 100 Mb/s transmission over two pairs
of Category 5 twisted-pair Ethernet wiring; one pair each for transmit and
receive operations.
The maximum recommended cable segment length is 100 meters between a
100BASE-TX repeater and a workstation (due to signal timing requirements).
This wiring scheme complies with the EIA 568 wiring standard.
Figure 3 shows the Contivity connector’s 10/100BASE-TX pinouts.
Figure 3 10/100BASE-TX pinouts
RD+RD- TD+ RD12345678
CS260010A
10BASE-T connections can use Category 3, 4, or 5 twisted-pair wiring. The
LAN connectors on the rear of the Contivity are RJ-45 straight through.
311862-A Rev 00
Chapter 2 Cabling and LEDS 27
Single WAN interface V.35 or X.21 (optional)
The V.35/X.21 WAN connector is located on a PCI card that offers a separate
DB28S connector that provides the signals needed to interface to V.35/X.21
equipment. Included in the accessory box is a cable that must be ordered
separately; one that maps the signals to a standard V.35 connector, or one that
maps the signals to an X.21 connector. You will need a DSU/CSU (digital service
unit/channel service unit) between the WAN connection and the Contivity. This
section documents the connector and cables used with the V.35 and/or those used
with X.21 WAN Synchronous Adapters.
The cables provided with the WAN PCI card enable the WAN adapter to function
as DTE (Data Terminal Equipment). Figure 4 shows the single V.35/X.21 WAN
interface.
Figure 4 Single V.35/X.21 WAN interface
LED 4, Red
LED 2, Green
LED 3, Green
LED 1, Green
CS160011A
Single V.35 WAN interface
Getting Started with the Contivity 600
28 Chapter 2 Cabling and LEDS
Table 2 shows the DB28S-to-V.35 cable pinouts.
Table 2 DB28S-to-V.35 cable pinouts
Standard-wired end
28-pin male
Signal name
Pair # &
conductor
Special-wired end
34-pin male
2
TXDA
pair 1A
P
14
TXDB
pair 1B
S
3
RXDA
pair 2A
R
16
RXDB
pair 2B
T
15
TXCA
pair 3A
Y
12
TXCB
pair 3B
AA
17
RXCB
pair 4A
V
9
RXCB
pair 4B
X
24
SCTEA
pair 5A
U
11
SCTEB
pair 5B
W
4
RTSA
pair 6A
C
19
RTSB
pair 6B
no conn
5
CTSA
pair 7A
D
13
CTSB
pair 7B
no conn
6
DSRA
pair 8A
E
22
DSRB
pair 8B
J
20
DTRB
pair 9A
H
23
DTRB
pair 9B
no conn
8
DCDA
pair 10A
F
10
DCDB
pair 10B
no conn
18
LL
pair 11A
L
21
RL
pair 11B
N
25
TM
pair 12A
NN
26
M0<-SIGNAL GROUND
pair 12B
B
Note 3
27
M1<-SIGNAL GROUND
pair 13A
B
Note 3
28
M2
pair 13B
no conn
Note 2
1
SHIELD
pair 14A
A
Note 1
7
SIGNAL GROUND
pair 14B
B
Note 3
Notes
Note 2
Note 2
Note 2
Note 2
The following notes apply to the Single V.35 DTE cable:
1. At each end, the cable shield and connector shell must connect respectively to pin A of the 34-pin
connector and pin 1 of the standard 28-pin connector.
2. The term “no conn” means the wire is not connected to a pin in the 34-pin connector.
3. Wires 12B, 13A, and 14B connect to pin B in the 34-pin connector.
4. Unused pins in the 34-pin connector need not be present.
5. Do not connect Shield to Signal Ground as these are separate signals.
6. The pair suffix A or B refers to an individual wire within a twisted pair.
311862-A Rev 00
Chapter 2 Cabling and LEDS 29
Table 3 shows the DB28S-to-X.21 cable pinouts.
Table 3 DB28S-to-X.21 cable pinouts
Standard-wired end
28-pin male
Signal name
Pair ## &
conductor
Special-wired end
37-pin male
2
TXDA
pair 1A
2
14
TXDB
pair 1B
9
3
RXDA
pair 2A
4
16
RXDB
pair 2B
11
15
TXCA
pair 3A
6
12
TXCB
pair 3B
13
17
RXCB
pair 4A
pair 5a
Note 5
9
RXCB
pair 4B
pair5b
Note 5
24
SCTEA
pair 5A
pair4a
Note 5
11
SCTEB
pair 5B
pair4b
Note 5
4
RTSA
pair 6A
3
19
RTSB
pair 6B
10
5
CTSA
pair 7A
12
13
CTSB
pair 7B
no conn
6
DSRA
pair 8A
no conn
Note 2
22
DSRB
pair 8B
no conn
Note 2
20
DTRB
pair 9A
no conn
Note 2
23
DTRB
pair 9B
no conn
Note 2
8
DCDA
pair 10A
no conn
Note 2
10
DCDB
pair 10B
no conn
Note 2
18
LL
pair 11A
no conn
Note 2
21
RL
pair 11B
no conn
Note 2
25
TM
pair 12A
no conn
Note 2
26
M0
pair 12B
no conn
Note 2
27
M1
pair 13A
no conn
Note 2
28
M2<-SIGNAL GROUND
pair 13B
8
Note 3
1
SHIELD
pair 14A
1
Note 1
7
SIGNAL GROUND
pair 14B
8
Note 3
Notes
The following notes apply to the Single X.21 DTE cable:
1. At each end, cable shield and back shell must connect to pin 1 of connector.
2. "no conn" means the wire is not connected to a pin in the 15-pin connector.
3. Wires 13B and 14B connect to pin 8 in the 15-pin connector.
4. Unused pins in the 15-pin connector need not be present.
5. Wires of pair 4 connect to wires of pair 5, but not to any pins in the DA-15. Do NOT interconnect Shield to
Signal Ground – they are separate signals.
6. The pair suffix A or B refers to an individual wire within a twisted pair.
Getting Started with the Contivity 600
30 Chapter 2 Cabling and LEDS
T1 CSU/DSU WAN interface
Note: The T1 CSU/DSU WAN interface cable is not supplied by Nortel
Networks.
This cable has 8-pin male connectors on each end. The T1 CSU/DSU WAN
crossover cable crosses the blue wire pair with the orange wire pair. This is
different from the commonly available crossover cable used for 10BaseT, which
crosses the green wire pair with the orange wire pair. Figure 5 shows the T1 CSU/
DSU interface.
Figure 5 T1 CSU/DSU interface
LED 4, Red
LED 2, Blue
LED 3, Green
LED 1, Yellow
CS160012A
311862-A Rev 00
Chapter 2 Cabling and LEDS 31
Table 4 shows the T1 CSU/DSU cable pinouts.
Table 4 T1 CSU/DSU cable pinouts
Standard-wired
end
28-pin male
Signal name
Pair # &
conductor
Special-wired end
8-pin male
1
RXDA->TXDA
wht/org pair 2A
5
2
RXDB>TXDA
orange pair 2B
4
3
not used
wht/grn pair 3A
3
4
TXDB<-RXDB
blue pair 2B
2
6
TXDA<-RXDA
wht/blu pair 1A
1
7
not used
green pair 3B
6
8
not used
wht/brn pair 4A
7
9
not used
brown pair 4B
8
Notes
The cable will operate properly if pins 3, 6, 7, and 8 are not connected.
Warning: Do not use Ethernet cable. The T1 CSU/DSU will appear to
work, but will not work to specifications. Data may be corrupted.
Getting Started with the Contivity 600
32 Chapter 2 Cabling and LEDS
Serial interface cable
Nortel Networks ships a serial cable with the Contivity to enable configuration of
the Management IP address, subnet mask, default gateway address, and other
configurable parameters. Nortel Networks recommends that you use the IP
Address Configuration Utility diskette for easy initial IP address configuration.
Later, you can use the serial interface configuration menu to perform management
functions.
Note: For information on serial interface connection, refer to Managing
the Contivity Extranet Switch, Chapter 2, “Getting Started.”
The serial cable provided with the Contivity is a DB9/DB25-to-DB9/DB25. This
provides a crossover (transmit-to-receive and receive-to-transmit). The DB9
connector goes into the Contivity and the other DB9 or DB25 connector goes into
your workstation. Table 5 shows the multiple cable DB9/DB25 serial interface
cable pinouts.
Table 5 Multiple DB9 and DB25 connector pinouts
Serial Port DB9 Connector
Serial Port DB25 Connector
Serial Port DB25 Connector
Serial Port DB9
Connector
Pinout
Signal
Pinout
Signal
Pinout
Signal
Pinout
2
RXD
3
TXD
>
2
RXD
3
TXD
3
TXD
2
RXD
>
3
TXD
2
RXD
4
DTR
20
DSR
>
6
DTR
6
DSR
5
Ground
7
Ground
>
7
Ground
5
Ground
6
DSR
6
DTR
>
20
DSR
4
DTR
7
RTS
4
RTS
>
5
CTS
8
CTS
8
CTS
5
CTS
>
4
RTS
7
RTS
311862-A Rev 00
Signal
Chapter 2 Cabling and LEDS 33
Understanding the LEDs
Front panel LEDs
The front panel, shown in Figure 6, has five lighted LEDs that indicate the status
of the Contivity.
Figure 6 Front panel LEDs
•
•
•
•
•
The Power LED is green when DC power is supplied to the unit.
The Alert LED is set to red by the Contivity software to indicate an serious
condition. This LED indicates the Health Check status that is described in
Health Check reports. Refer to Managing the Contivity Extranet Switch for
information on Health Check.
The Attention LED is yellow to indicate a software attention condition. Refer
to Managing the Contivity Extranet Switch for information on Health Check.
The Ready LED is green to indicate that the box has reached a state of
readiness.
The Boot LED is yellow after power is applied. Yellow indicates a boot in
process/non-ready state. When both the Boot and the Ready LED are lit at the
same time, this indicates that the unit has entered recovery mode.
Getting Started with the Contivity 600
34 Chapter 2 Cabling and LEDS
LAN LEDs
Figure 7 shows the LAN0 and LAN1 port LEDs located on the back of the
Contivity Table 6 shows the corresponding LEDs.
Figure 7 LAN Port LEDs
Orange
Green
Table 6 LAN port LED indicators
LED
Indicator
Description
Yellow
On
The cable connections between the LAN port
and the hub are good.
Off
The cable connections between the LAN port
and the hub are faulty.
Flashing
The LAN port is sending or receiving network
data. The frequency of the flashes increases
with increased traffic.
On
The LAN port is operating at 100 Mb/s.
Off
The LAN port is operating at 10 Mb/s.
Green
Start the Contivity and confirm that the LAN interfaces are cabled properly by
examining LEDs located on the rear panel of the Contivity.
311862-A Rev 00
Chapter 2 Cabling and LEDS 35
V.35/X.21 single LEDs
Figure 8 shows the Single V.35/X.21 LEDs. Look at the condition of the LEDs
located on the LMC 1000 Single V.35 WAN PCI interface card.
Table 7 shows the corresponding LEDs.
Figure 8 Single V.35/X.21 LEDs
LED 4, Red
LED 2, Green
LED 3, Green
LED 1, Green
CS160011A
Table 7 Single V.35/X.21 LED indicators
LED
Description
LED1, Green
Power is on to the adapter and the onboard microcode is loaded.
LED2, Green
The signals CDC and DSR are on between the DSU and the
adapter. LED2 detects receive link status.
LED3, Green
Cable is detected.
LED4, Red
No external transmit clock source is available.
Getting Started with the Contivity 600
36 Chapter 2 Cabling and LEDS
T1 CSU/DSU LEDs
Figure 9 shows the T1 CSU/DSU LEDs. Look at the condition of the LEDs
located on the T1 Integrated CSU/DSU PCI interface card. Table 8 shows the
corresponding LEDs.
Figure 9 T1 CSU/DSU LEDs
LED 4, Red
LED 2, Blue
LED 3, Green
LED 1, Yellow
CS160012A
Table 8 T1 CSU/DSU LED indicators
LED
Description
LED1, Yellow
Yellow alarm LED is lit when the far-end equipment is in the red alarm
condition.
LED2, Blue
Blue alarm LED is lit when receiving an upstream failure denoted by an
alarm indication signal (AIS).
LED3, Green
Normal operation.
LED4, Red
Red alarm is lit when a loss-of-signal (LOS) or out-of-frame (OOF)
condition is detected on the receive signal.
311862-A Rev 00
Chapter 2 Cabling and LEDS 37
Public LAN LEDs
Figure 10 shows the PCI card 10/100BASE-TX public LAN LEDs. Look at the
condition of the LEDs. Table 9 shows the corresponding LEDs.
ACT/LINK
100TX
DATA
Figure 10 10/100BASE-TX LAN LEDs
Activity/Link
10/100Mbs
CS260009A
Table 9 10/100BASE-TX LAN LED card indicators
LED
Indicator
Description
ACT/LINK,
Green
On or
Flashing
The card is sending or receiving network data. The
frequency of the flashes increases with increased traffic.
Off
The card is not sending or receiving data.
On
Operating at 100 Mb/s.
Off
Operating at 10 Mb/s.
10/100 TX,
Green
Getting Started with the Contivity 600
38 Chapter 2 Cabling and LEDS
311862-A Rev 00
39
Chapter 3
Changing Hardware Configurations
The expansion slot is renamed to Slot 2 by the Contivity software.
Warning: Wear an antistatic band when handling electronic
components for the Contivity to avoid damaging them.
Note: Unplug the Contivity 600 before installing LAN or WAN
interface cards.
To install LAN or WAN cards you must remove four screws on the bottom of the
Contivity and slide the inner chassis out of the casing. You will need to unscrew
the PCI interface bracket screw and remove the PCI interface card or blank PCI
bracket. Then you will install a new PCI interface, being careful to completely
press the card into the PCI connector on the mother board. Next you will replace
the chassis (along the guide rails) in the outer casing and replace the bottom
screws. This procedure is detailed in the steps that follow.
Getting Started with the Contivity 600
40 Chapter 3 Changing Hardware Configurations
Removing the rear of the chassis to access the system
You must remove the bottom metal screws and pull the chassis from the rear to
access the system. Figure 11 shows you how to remove the bottom screws from
the Contivity.
To remove the bottom chassis, you need a Phillips screwdriver.
1
Unplug the Contivity’s power cord.
2
Tip the Contivity up on end or turn it over to see the bottom of the box.
3
Using the Phillips-head screwdriver, remove the four screws that secure the
bottom to the chassis as shown in Figure 11.
Figure 11 Removing the bottom screws
1
2
3
4
CS60003A
311862-A Rev 00
Chapter 3 Changing Hardware Configurations 41
4
Firmly pull the chassis towards you to loosen it from the casing. You can
gently shake it so that it slips outwards and into your hand or you can pull
gently on the I/O expansion bay. Figure 12 is a photograph of how to remove
the system from the casing.
Figure 12 Removing the system from the casing
Getting Started with the Contivity 600
42 Chapter 3 Changing Hardware Configurations
Figure 13 Removing the chassis from the rear of the Contivity
l
I/O EXPA
NSION
CONSOL
E
BAY
LAN 1
FD
LAN 0
RC
DC INPU
+12V-1. T
7A
-12V-0.1
A
+5V-10
A
75W MA
X
CS60004A
Figure 14photographic view of the Contivity 600 system board,
Figure 14 Photographic view of the Contivity 600 system board
311862-A Rev 00
Chapter 3 Changing Hardware Configurations 43
Figure 15 shows a simplied drawing of the mother board.
Figure 15 Simplified drawing of the Contivity 600 mother board
Option card slot
CPU
cooling fan
DIMM slot
CS60005A
Warning: Beware of danger if the battery is incorrectly replaced.
Replace with the same or an equivalent battery only, as recommended
by the manufacturer’s instructions.
Danger: In spite of the above warning, which is mandated for
regulatory approval, you should not change the battery. If you suspect a
dead battery, contact Nortel Networks Customer Support.
This section shows you how to install LAN or WAN option cards into the
Contivity.
To open the Contivity, you need a Phillips screwdriver:
Getting Started with the Contivity 600
44 Chapter 3 Changing Hardware Configurations
1
Power off the Contivity.
2
Remove the power cord.
3
Remove the bottom screws as shown in Figure 16:
Figure 16 Removing the bottom screws
1
2
3
4
CS60003A
311862-A Rev 00
Chapter 3 Changing Hardware Configurations 45
4
Remove the system from the chassis, as shown in Figure 17.
Figure 17 Removing the chassis
l
I/O EXPA
NSION
CONSOL
E
BAY
LAN 1
FD
LAN 0
RC
DC INPU
+12V-1. T
7A
-12V-0.1
A
+5V-10
A
75W MA
X
CS60004A
Getting Started with the Contivity 600
46 Chapter 3 Changing Hardware Configurations
5
Remove the blank PCI bracket, as shown in Figure 18 and Figure 19.
Figure 18 Removing a blank PCI bracket
311862-A Rev 00
Chapter 3 Changing Hardware Configurations 47
6
Remove the blank PCI card shown in Figure 19 by inserting a Phillips head
screw driver into the slot at the right of the PCI card and rotating the screw
counter-clockwise.
Figure 19 Removing a blank option card
Getting Started with the Contivity 600
48 Chapter 3 Changing Hardware Configurations
Figure 20 shows the blank option card after the screw has been removed.
Figure 20 Blank option card after screw removed
7
Lift out the blank option card, and slide the replacement card into the intended
slot.
Note: Be careful not to bend the copper inserts.
Make sure the card seats firmly and evenly in the card slot and that the left
tabbed-end of the card is seated in its slot. If the card is not seated properly, it
will not work.
311862-A Rev 00
Chapter 3 Changing Hardware Configurations 49
8
Replace the screw at the right end of the PCI card as shown in Figure 21.
Figure 21 Replacing screw at right end of the PCI card
9
Slide the unit into the casing as shown in Figure 22.
Getting Started with the Contivity 600
50 Chapter 3 Changing Hardware Configurations
Figure 22 Replacing chassis in casing
10 Turn over the Contivity and replace the four Phillips head screws to secure the
bottom panel.
11 Reconnect your power supply and restart your Contivity 600.
311862-A Rev 00
51
Chapter 4
Using Recovery Mode
The Contivity 600 recovery mode is build into the onboard flash operating
system. Other than having recovery built into the unit, recovery in a 600 runs the
same way as the floppy-based Contivity products do. Use the recovery mode to
restore software to an existing Contivity 600 unit.
Some web pages refer to the diskette or recovery diskette. In the case of the
Contivity 600, this is a virtual diskette. There is no diskette to remove; the image
is built into the flash operating system.
In addition, there is no reset button on a Contivity 600 unit. Resetting the
Contivity 600 is accomplished by removing power from the 600 and then
restoring power.
To enter recovery mode, use the following procedure:
1
Plug in the console cable, the LAN0 cable, and the DC input cable from the
Contivity 600 power supply.
2
Run hyperterm on your PC and connect to the console port of the Contivity
600.
3
Apply AC power to the power supply.
4
Depress the switch on the rear of the Contivity, accessible with a paper clip
through the hole marked RC in the chassis. The RC (recovery) switch is on
the rear of the unit between the DC input cable and the LAN0 cable.
On your console you will see the BIOS banner and the Nortel Networks
Contivity banner. You will then observe the unit execute its power on self test.
You can press the switch anytime during the power tests. A momentary press
is all that is required. There is no need to hold the button down.
Note: After executing power on self test, the console displays “Booting
recovery image.”
Getting Started with the Contivity 600
52 Chapter 4 Using Recovery Mode
Booting the recovery image takes approximately 40 seconds. After the
recovery image boots, the Contivity 600 displays the welcome message, the
recovery image version, and a prompt for you to enter the administrator’s user
name. At this point you are in recovery mode.
5
Enter a management IP address, subnet mask, and gateway if they are not
already assigned. You do this from the console menu after logging in as an
administrator.
Once the unit has a management IP address, you can manage the unit from the
web interface.
Note: The switch marked FD is reserved for future use. Depressing this
switch has no effect.
At your Web browser, enter the Management IP address of your Switch. The
Recovery mode display shown in Figure 23 appears, which allows you to:
•
•
•
•
•
•
•
311862-A Rev 00
Restore the factory default configuration or the backup configuration.
Restore a backup software image.
Reformat the Switch’s hard disk.
Apply a new software version to the Switch.
Perform file maintenance.
View the Event log.
Restart the system.
Chapter 4 Using Recovery Mode 53
Figure 23 Recovery diskette display
Getting Started with the Contivity 600
54 Chapter 4 Using Recovery Mode
1
Restore the configuration:
To restore the factory default configuration or the backup configuration, do
one of the following:
➨ Restore the factory configuration by selecting Restore Factory Configuration,
then clicking Restore to return the Switch to its original factory default
configuration. This erases data contained in flash memory and also in the
configuration file.
Warning: Selecting this option requires you to rebuild your entire
Switch configuration again from scratch.
An online message specifies the result of the Factory Configuration reset
action.
➨ Or, you can restore the Switch’s previously backed-up configuration by
clicking Restore. If you previously chose to automatically back up the file
systems, then the Backup Server Host (or IP address) and Path Name, User
ID, and Password appear in the table.
Click the radio button of the preferred backup server. The backed-up file
system, including software image and configuration files, from the latest
backup copy residing on the designated server will be restored onto the hard
drive of your Switch.
You can use the same backup server for multiple Switches. Each Switch
creates a unique directory based on its serial number. The following example
shows the host, path, and serial number:
C:/software/backup/v101/SN01001
The serial number is used to differentiate backup configurations from multiple
Switches that are saved on the same backup server. The serial number
uniquely identifies each Switch’s backup data.
A blank row in the server backup field always appears to allow you to
manually enter a backup server in case you did not configure automatic
backup server locations.
311862-A Rev 00
Chapter 4 Using Recovery Mode 55
Alternatively, a new factory default software image and file system can be
restored to the Switch’s hard disk. Specify the name or address and path of the
network file server onto which the software from the Nortel Networks CD has
been installed.
Note: This will restore the disk to an operable but “clean” condition (for
example, configuration values will be at factory defaults).
To view your Switch’s serial number when the Switch is operational, click
Status→System from the Navigational Menu. The serial number is also listed
on the bar code label on the back of the Switch.
2
Click Reformat your Switch’s Hard Disk if you must reformat the hard disk;
for example if you:
— Have problems restoring your configuration that are not caused by the
network or the file/backup server from which the file restoration is being
retrieved.
— Want to reconfigure the Switch from scratch.
Caution: Selecting this option will completely wipe out anything that
previously resided on the hard disk.
An online message indicates whether the reformatting of the hard disk was
successful.
3
Click the drop-down list box to view the available software image and file
systems that are stored on the remote disk and select the image version that
you want to activate.
4
Click Files to bring up the File Maintenance display, which allows you to
view the entire hard disk file system.
Getting Started with the Contivity 600
56 Chapter 4 Using Recovery Mode
5
Click View to display the Event Log beneath the Recovery Diskette display.
This is especially useful if a Restore operation fails.
6
Reset the system after recovery operation by unplugging the unit. Either AC
or DC power may be interrupted momentarily to accomplish this. Then
reposition your Web browser to the Management IP address, and press Reload
or Refresh from your browser menu to access the management page of the
software running on the hard disk.
311862-A Rev 00
57
Chapter 5
Assigning a System Identity
This section describes how to assign a Management IP address, subnet mask, and
optional default gateway address to your Switch. The Management IP address is
used for all system services, such as HTTP, FTP, and SNMP. The Management IP
address enables you to manage the Switch from a Web browser.
Table 10 describes the choices you have when first configuring the required
Switch parameters.
The IP Address Configuration Utility diskette, which comes with your Switch,
searches for the serial numbers of unconfigured Switches. It then displays a table
for you to enter the Management IP address, subnet mask, and default gateway
(optional).
To configure the Switch from the serial interface configuration menu, you must
first connect the serial interface cable to the Switch. Then you can use a terminal
emulation application to enter the Management IP address, subnet mask, and
default gateway (optional).
Table 10 Initial configuration options
Initial configuration
method
IP Address Configuration
Utility (recommended)
Serial Interface
Configuration Menu
(optional)
Advantages/
disadvantages
Result
Sets Management IP
address, subnet mask, and
default gateway (optional)
Utility diskette makes initial
configuration easy
Must connect the serial
interface cable
Getting Started with the Contivity 600
58 Chapter 5 Assigning a System Identity
Startup configuration requirements
This section describes the fields that you must complete with either the IP Address
Configuration Utility or the serial interface configuration menu procedure.
Management IP address
Enter a Management IP address for the system. You need this address to manage
all system services, such as HTTP, FTP, and SNMP. This address must be
accessible from one of the Switch’s private physical interfaces. Therefore, the
Management IP address must map to the same network as one of the private
interfaces.
For example, if you plan to assign IP address 10.2.3.3 with subnet mask
255.255.0.0 to the private physical interface, then the Management IP address
must reside in the 10.2 network.
Carefully record the Management IP address. Later, during the Quick Start or
the Guided Configuration, you will be asked to supply IP addresses for the
physical interfaces.
Subnet mask
The subnet mask defines how many bits of the IP address represent the network
the device is on and how many bits represent the host’s ID on the network.
The device uses the subnet mask to determine which IP addresses are directly
reachable on the network and which ones must be routed through a gateway. A
sample IP address is 10.2.3.3 with a subnet mask of 255.255.0.0. This indicates
that all hosts with addresses 10.2.n.n, where n is any number 0 - 255, are directly
reachable.
Default gateway
The default gateway is where packets are routed onto the private or public
network if there is not a specific route in the routing table to the desired location.
311862-A Rev 00
Chapter 5 Assigning a System Identity 59
IP address configuration utility
Use this utility for the initial Switch configuration.
Requirements
To assign the Switch a Management IP address with this utility, you need:
•
•
•
A PC running Windows 95, Windows 98, Windows NT, or Windows 2000
with a functioning TCP/IP stack
The PC running on the same subnet as the Switch you are configuring
The PC connected to an operational network connection
If your environment does not match these requirements, then you must use the
serial interface configuration.
To test the function of your TCP/IP stack, send a PING command to any host.
Running the IP configuration utility
The program ExtNetIP.exe is on a diskette labeled IP Address Configuration
Utility that accompanies the Switch. You can copy the utility to your hard disk and
execute it from there, or you can load it from the diskette drive. The ExtNetIP.exe
program launches the IP Address Configuration Utility, which allows you to
assign a Management IP address and subnet mask to the Switch. To run
ExtNetIP.exe:
1
Insert the diskette into the A: drive and select Start → Run, and then type:
a:\ExtNetIP.exe
or open the “My Computer” icon on the desktop and open the “3½ Floppy
(A:)” drive, and then double-click on the icon shown in Figure 24.
Getting Started with the Contivity 600
60 Chapter 5 Assigning a System Identity
Figure 24 The ExtNepIP.exe icon
The display shown in Figure 25 appears while the program searches for an
unconfigured Switch.
Figure 25 The serial number search display
The program automatically enters the Serial Number for the first available
Switch into the table of Contivity Switches.
Figure 26 Extranet address configuration utility display
311862-A Rev 00
Chapter 5 Assigning a System Identity 61
2
Assign a Management IP address and subnet mask to the Switch; the
Default Gateway address is optional and can be added later (refer to
“Startup Configuration Requirements” for descriptions of the
required fields).
3
If you have more than one Switch, click Search to automatically add the
additional Switch serial numbers. To verify the switches that have been
discovered, you can refer to the serial number on the bar code on the bottom
of the Switch.
4
Click Apply to configure the Management IP address, subnet mask,
and default gateway on the Switch. The Extranet Address Configuration
Utility display disappears.
5
When the Switch has completed updating its configuration with the
Management IP address, subnet mask, and optional default gateway, your
default Web browser will open automatically to the Contivity Extranet Switch
Welcome display.
6
Click Close to shut down the Extranet Address Configuration Utility.
Note: Before moving the Switch from one network to another, change
the Management IP address, subnet mask, and default gateway.
Otherwise, you will need to follow the Serial Interface Configuration
procedure to access your Switch because it will not be accessible from a
Web browser with an invalid address.
Serial interface configuration
Use the IP Address Configuration Utility to configure the Switch with its initial IP
address.
Alternatively, you can use the serial interface configuration menu to access the
Switch via the serial interface of your PC. The serial interface configuration menu
allows you to give the Switch a Management IP address, subnet mask, and
gateway IP address so that you can use a Web browser for management.
Getting Started with the Contivity 600
62 Chapter 5 Assigning a System Identity
Prerequisites
The terminal emulator on your PC must use the following communications
parameters:
•
•
•
•
•
9600 baud
8 data bits
1 Stop bit
No parity
No flow control
Procedure
To configure the serial interface:
1
Connect the serial cable from the Switch’s serial cable port to a PC
communications port. Turn on the Switch. It can take the system
approximately three minutes to start up.
2
Using a terminal emulation program, such as Hyper Terminal, press Enter and
then supply a user name and password. The factory default user name and
password are:
User name: admin
Password: setup
A menu appears that allows you to enter the following:
•
Management IP address
•
IP subnet mask
•
Gateway IP address (optional)
A sample display follows:
Welcome to the Nortel Networks Extranet Switch
Copyright 1998 and 2000, Nortel Networks
Date: 1/29/00
Unit Serial Number: 01001
Please enter the administrator’s username: admin
311862-A Rev 00
Chapter 5 Assigning a System Identity 63
Please enter the administrator’s password: setup
1)
2)
3)
4)
5)
C)
R)
E)
Management IP Address*
IP Subnet Mask
Gateway IP Address*
Allow HTTP Management
Interface IP Address*
Controlled Crash
Reset to Factory Defaults
Exit
*0.0.0.0 resets to factory default value of NULL
Please select a menu choice (1 - 5, C, R, E):
3
Follow the screen prompts. Some of the descriptions of the fields required to
complete this procedure are in the section “Startup Configuration
Requirements.”
4
After you complete the configuration, type E to Exit. You can then manage
the Switch from a Web browser.
Note: This administrator’s password is also the primary administrator’s
password. This password guarantees access to the Switch via the serial
port or a Web browser.
Getting Started with the Contivity 600
64 Chapter 5 Assigning a System Identity
311862-A Rev 00
65
Appendix A
Specifications
Table 11 shows the physical specifications and operating environment for the
Contivity 600.
Table 11 Physical specifications and operating environment
Specification
Description
Physical
Depth
10.75 in. (27.30 cm)
Width
8 in. (20.32 cm)
Height
4 in. (10.16 cm)
Weight
7 lbs. (3.175Kg)
Electrical
Voltage
100 - 240 VAC
Current
1.9 A
Frequency
47/63 HZ
Operating environment
Temperature
32 - 110o F (0 - 45o C)
Relative Humidity
10 - 90% noncondensing
Getting Started with the Contivity 600
66 Appendix A Specifications
311862-A Rev 00
67
Index
Numbers
documentation map 14
100BASE-TX interface 26
DSU/CSU
required 27
10BASE-T interface 26
A
F
acronyms 15
factory default 52, 54
configuration 54
B
G
backup
configuration 54
gateway IP address
serial interface 62
C
H
Category 3, 4
wiring requirements 26
hard drive
reformat 55
Category 5
wiring requirements 26
connecting cables 24
conventions 15
I
IP address 58
configuration utility 61
conventions, text 15
customer support 17
L
D
LAN cards
installing 43
DB26S to V.35
connector 27
pinouts 27
P
DB9 or DB25
connectors 32
default gateway 58
product support 17
publications
hard copy 16
diskette
IP Address Configuration Utility 59
Getting Started with the Contivity 600
68 Index
R
W
recovery diskette
drive 40
WAN cards
installing 43
RJ-45
pinouts 26
WAN connection
DSU/CSU 27
Web browsers 61
S
safety
power off 43
serial cable connectors 32
serial interface
configuration requirements 61
connector 32
serial number 54
software
version 55
new 52
support, Nortel Networks 17
system identity
assigning 57
system IP address
serial interface 62
system IP subnet mask
serial interface 62
T
technical publications 16
technical support 17
terminal emulation
communication requirements 62
serial interface 62
text conventions 15
U
user interface 17
311862-A Rev 00
">
/
Stáhnout
Jen přátelské upozornění. Dokument si můžete prohlédnout přímo zde. Ale co je nejdůležitější, naše AI si ho již přečetla. Dokáže složité věci vysvětlit jednoduchými slovy, zodpovědět vaše otázky v jakémkoli jazyce a pomoci vám rychle se orientovat i v těch nejdelších nebo nejsložitějších dokumentech.