INSTALLATION MANUAL Clean Dry™
High Speed Concealed Hand Dryer
Warranty Registration and Inquiry
For product warranty registration, TOTO U.S.A. Inc. recommends online Warranty Registration. Please visit our web site http://www.totousa.com. If you have questions regarding warranty policy or coverage, please contact TOTO U.S.A. Inc., Customer Service Department, 1155 Southern Road, Morrow, GA 30260 (888) 295 8134 or (678)466-1300 when calling from outside of U.S.A.
Important Safeguards
(For your safety, please follow the instructions below.)
In this Instruction Manual, the following symbols are shown for safe and proper use of the product and to alert you of the possibility of personal injury and damage to your property.
The symbols and their meanings are as follows:
Important
Warning
It is necessary to install a circuit-breaker in the power supply
Failure to do this may cause electric shock during overload or short circuit.
Warning Ignoring these symbols may cause personal injury and/or property damage.
Important
Caution
The chassis assembly must be installed on a smooth and even wall surface which has enough strength.
Failure to do this may cause damage or personal injury if it falls down.
Caution Ignoring these symbols may cause severe injury and/or property damage.
*Some models may have different components from the ones illustrated below.
Specification
Warning
Do not install the unit in the places where corrosive or combustible gas can be present.
Product
Power Rating
HDR110#SS
120V AC, 4.25 Amps, 60 Hz, 510 W
Do not This may cause product failure or damage.
Power Connection Hardwiring
Power Saving Function Automatically turns OFF after 60 seconds of use
Do not disassemble
Do not use in humid area
Never attempt to disassemble for repair or modification.
This may cause electric shock, fire, injury or failure
Do not install outdoors or where it is exposed to water.
This may cause current leakage, electric shock, fire, or failure.
Decibel Rating
Air Speed
Dry Time
Drain Tray Capacity
Ambient temperature
Size
Weight
58 dB
224 mph (100 meters/second)
12 seconds
0.27 gal (950 ml)
32° - 104°F (0° - 40°C)
9-5/8" x 18-1/2" x 6-5/16"
22.2 lbs (10kg)
0GU3049E 2009.04
Before Installing
1. Precautions
Confirm the rough-in, major dimensions and wiring diagram before installation in order to properly install the hand dryer and electrical wiring.
All electrical wiring should be installed in accordance with national/local codes and regulations with assistance from a certified electrician.
Mounting surface should be even and smooth.
Confirmation must be made that the wall has enough strength for hand dryer installation and be sure to use all the mounting hardware provided to securely
install the hand dryer.
It is necessary to install circuit breaker for the power supply.
2. Others
Pay special attention so that both the top cover and the sensor surface are not flawed or scratched.
Do not place other devices using inverter or infrared sensor near the hand dryer, this may cause malfunction.
*
Recommended mounting bracket heights from floor are as follow:
- Male/Female: 29-1/2” (750 mm)
- Children: 23-1/2” (598 mm)
- Handicapped: 21-1/2” (547 mm)
Meets the American Disabilities Act Guidelines, ANSI A117.1 and CSA B651 requirements when mounted in a recessed wall where the front surface is not more than 4” (102mm) from finished wall and max. height of air blower outlet from finished floor is 47-1/4” (1200mm).
Set-up Drawing
Some models may have different components as illustrated below.
1-9/16″ (40mm)
3-9/16″ (90mm)
2-3/8″ (60mm)
2-3/8″ (60mm)
1-5/16″
(34mm)
5-1/8″
(130mm)
FINISHED
WALL
11-13/16″
(300mm)
1-9/16″
(40mm)
Junction box location
2″ (50mm)
2-3/4″ (70mm)
2-3/4″ (70mm)
3-1/8″ (80mm)
1-3/16″ (30mm)
26-5/16″
(668mm)
28-3/4″
(730mm)
2″
(50mm)
OPEN WALL
12-5/8″
(320mm)
1-9/16″
(40mm)
6-7/16″
(164mm)
5-1/8″
(130mm)
*
FLOOR
Installation
*Some models may have different component as illustrated below.
Hand Dryer Unit
Top cover
Color : White,Black,Green
Size : AWG16×3
Power Cable
Sensor
Air nozzles
Wall surface
Wiring Hole
Chassis Assy
Filter
<Bottom view>
Filter case
w/o Top Cover
Junction box
(Connection type)
<View with cover removed>
Water Tray
Filter case
Drain tray
Accessories
Mounting Bracket
Bracket (Top)
Screws and Vandal Resist Hex Wrench
※ Model is subject to change without further notification.
Installation Manual Template
(M4×6) ×2
(φ4.5×30) ×6
Bracket (Bottom)
Installation Procedure
STEP 1
1 Using template provided, mark the wall for locations and install the mounting bracket.
Wall thickness needs to be 5 to 30mm.
1-9/16 ″
( 40mm)
3-9/16″ (90mm)
2-3/8″ (60mm)
2-3/8″ (60mm)
Beam/Stud
Finished wall
STEP 1
Mark the wall with template and install the bracket
Caution
Chassis Assy. must be installed on a rigid and even surface
Failure to do this may cause damage or personal injury when it falls.
・
Attach the bracket firmly on the rigid wall with the three screws ( φ4.5×30 ) provided.
・ In the case of a tile or concrete wall, please use plastic plug anchors with screws provided.
1-9/16 ″ (40mm)
3-9/16″ (90mm)
2-3/8″ (60mm)
2-3/8″ (60mm)
1-9/16 ″
(40mm)
Junction box location
Finished wall
3-1/8 ″
(80mm) 2-3/4 ″
(70mm)
2-3/4 ″
(70mm)
2 ″ ( 50mm)
1-3/16 ″ ( 30mm)
Wall thickness needs to be 5 to 30mm.
Bracket (Bottom)
1-9/16 ″
(40mm)
Drain tray
Remove drain tray during installation
Finished Wall
Wall
Beam/Stud
1-9/16 ″ ( 40mm) 2-3/4 ″ (70mm)
2-3/4 ″ (70mm)
3-1/8 ″ (80mm)
2 ″ ( 50mm)
1-3/16 ″ ( 30mm)
2 Complete the electrical wiring; install the junction box, and connect the power cord using wire nuts.
3 Mount the chassis assembly and drain tray assembly
4 Install the top cover and drain tray
*
Recommended mounting bracket heights from floor are as follow:
- Male/Female: 29-1/2” (750 mm)
- Children: 23-1/2” (598 mm)
- Handicapped: 21-1/2” (547 mm)
To be continued on the back
STEP 2 - STEP 3
STEP 2
Complete the electrical wiring
・ Place chassis assembly onto the bottom bracket.
・ Using wire nuts, connect power cable from hand dryer to power supply in the junction box (confirm with certified electrician on correct wire nuts to use).
・ Place connection point (with wire nuts) into the junction box.
・ Hang chassis assembly onto the top bracket.
STEP 3
Mount the Chassis Assembly and Drain Tray
Assembly
・
Make sure all electrical wiring is placed away inside the junction box.
・
Use 2 screws (M4) that come with the product and tighten unit to the bottom bracket.
Bracket (Top)
Junction box
(Actual Placement)
Screw in two screws onto bottom of body through the bottom bracket Junction box
(Actual Placement)
Connection point
Bracket (Bottom)
Chassis
Assy
Place mounting platform onto mounting bracket hooks.
Connection
Diagram
※ Connect the cord firmly with a wire nut or equivalent.
Junction box
(Actual Placement)
Place connection point (with wire nuts) into the junction box
Drain tray
Attach water tray after installation is complete
Chassis Assembly
1.
2.
Function Test
1. Checking after installation
■ Test the product as follows after the installation is complete.
・ First peel off the seal on the filter.
(The seal is used to protect the filter from scratches during shipment; it is no longer needed.)
Air nozzles
Peel off the seal
Check the circuit breaker
Check the functionality
■ After trial run
・ After you check the functionality by trial run, give the user manual
(with warranty) to the customer, and explain how to use and maintain the product.
Wiring Diagram
Sensor
P6
W
P7
W
P2
P1-1
W P1-2
Control
Assembly
Power
Connector
B
Power Fuse
15A
W
G
B
G
Motor
P3
Motor
Body Case
B=BLACK
R=RED
W=WHITE
Bu=BLUE
G=GREEN