Dahua ISC-M6550A Intelligent Security Screening Machine User's manual
Tangazo
Tangazo
User’s Manual
AI Single-energy Security Screening
Machine
User’s Manual
ZHEJIANG DAHUA VISION TECHNOLOGY CO., LTD.
V1.0.0
User’s Manual
Foreword
General
This manual introduces the installation, functions, and operations of the AI Single-energy Security
Screening Machine (hereinafter referred to as the "Device"). Read carefully before using the device, and keep the manual safe for future reference.
Application Scope
Models
This manual is mainly applicable to the following persons:
Administrator and operator of ISC series AI single-energy X-ray security screening machine.
ISC-M6550A
ISC-M5030A
Safety Instructions
The following categorized signal words with defined meaning might appear in the manual.
Signal Words Meaning
DANGER
Indicates a high potential hazard which, if not avoided, will result in death or serious injury.
WARNING
Indicates a medium or low potential hazard which, if not avoided, could result in slight or moderate injury.
CAUTION
Indicates a potential risk which, if not avoided, could result in property damage, data loss, reductions in performance, or unpredictable results.
TIPS Provides methods to help you solve a problem or save you time.
NOTE Provides additional information as the emphasis and supplement to the text.
I
User’s Manual
UI Icon/Button
Icon/Button
,
Description
Add: Click it to unfold the hidden application interface. You can view or activate the application.
Help: Point to it, and the interface shows guiding information.
Expand: Click it and the hidden menu items are displayed.
Check box that allows for selecting multiple menu items simultaneously. means the item is selected.
Radio button that allows for selecting a menu item. means the item is selected.
Drop-down list: Click it, and the drop-down menu items are displayed.
indicates the corresponding function is disabled.
indicates the corresponding function is enabled.
Search bar: Enter the keyword, and then click .
Matching information is displayed.
Textbox: Allows for entering numbers, letters, Chinese characters, symbols, and more.
Refresh: Click it to get the latest saved settings.
Cancel: Click it to cancel unsaved settings and return to the previous menu interface.
Close: Click it to close the window.
Revision History
Version Revision Content
V1.0.0 First release.
Release Time
March 2022
Privacy Protection Notice
As the device user or data controller, you might collect the personal data of others such as their face, fingerprints, and license plate number. You need to be in compliance with your local privacy protection laws and regulations to protect the legitimate rights and interests of other people by implementing measures which include but are not limited: Providing clear and visible identification to inform people of the existence of the surveillance area and provide required contact information.
I
User’s Manual
About the Manual
The manual is for reference only. Slight differences might be found between the manual and the product.
We are not liable for losses incurred due to operating the product in ways that are not in compliance with the manual.
The manual will be updated according to the latest laws and regulations of related jurisdictions. For detailed information, see the paper user’s manual, use our CD-ROM, scan the
QR code or visit our official website. The manual is for reference only. Slight differences might be found between the electronic version and the paper version.
All designs and software are subject to change without prior written notice. Product updates might result in some differences appearing between the actual product and the manual.
Please contact customer service for the latest program and supplementary documentation.
There might be errors in the print or deviations in the description of the functions, operations and technical data. If there is any doubt or dispute, we reserve the right of final explanation.
Upgrade the reader software or try other mainstream reader software if the manual (in PDF format) cannot be opened.
All trademarks, registered trademarks and company names in the manual are properties of their respective owners.
Please visit our website, contact the supplier or customer service if any problems occur while using the device.
If there is any uncertainty or controversy, we reserve the right of final explanation.
II
User’s Manual
Important Safeguards and Warnings
This section introduces content covering the proper handling of the Device, hazard prevention, and prevention of property damage. Read carefully before using the Device, and comply with the guidelines when using it.
Operation Requirements
WARNING
Before operating the Security Screening Machine, receive relevant training in radiation protection according to the requirements of local laws and regulations. If necessary, report the installation and operation of the Device to the local authority and conduct a radiation safety inspection. The dose rate of the Device outer surface needs to be checked regularly.
WARNING
Before operating the Security Screening Machine, know the relevant regulations and requirements for radiation protection.
WARNING
Do not drop or splash liquid onto the Device, and make sure there is no object filled with liquid on the Device to prevent liquid from flowing into the Device.
WARNING
Operate the Device within the rated range of power input and output.
WARNING
Do not use the Device and contact the local after-sales service department when the external cables, conveyor, lead curtains or indicator of the Device are damaged.
WARNING
Do not open the enclosure to operate the internal components. If the components need to be installed or changed, contact the local after-sales service department according to the information on the front page of this manual.
WARNING
Do not make any part of the human body (or other living bodies) enter the tunnel when the
Device starts to work.
WARNING
Disconnect the power supply to ensure safety during daily cleaning and maintenance of the
Device,
CAUTION
III
User’s Manual
Only after receiving Device operation training can the user operates the Device.
CAUTION
Do not place or install the Device in a place exposed to sunlight or near the heat source.
CAUTION
Keep the Device away from dampness, dust or soot.
CAUTION
Use the Device Indoor use only.
CAUTION
Keep the Device installed horizontally in a stable place to prevent it from falling.
CAUTION
Do not place the Device at places difficult to operate the disconnection device.
CAUTION
Install the Device in a well-ventilated place, and do not block the ventilation of the Device.
CAUTION
Do not disassemble the Device.
CAUTION
Transport, use and store the Device under the allowed humidity and temperature conditions.
CAUTION
Arrange a person on duty when the Device starts to work.
CAUTION
Place the inspected items on the conveyor or the roller table according to the requirements of the prompt signs at the entrance of the Device tunnel.
CAUTION
Watch the position of the inspected items after the conveyor starts to avoid blocking the tunnel or falling of the inspected items.
Electrical Safety
WARNING
Use the power adapter provided with the Device; otherwise, it might result in people injury and device damage.
WARNING
Connect the device (type-I structure) to the power socket with protective grounding.
IV
User’s Manual
WARNING
Connect the Device to the power socket with protective grounding: otherwise, the user is responsible for all the results.
CAUTION
Use the battery according to the requirements; otherwise, there might result in explosion.
When replacing the battery, make sure the same type is used. Improper battery use might result in fire, explosion, or inflammation.
CAUTION
Follow the instructions to dispose of the used battery.
CAUTION
Use the recommended power cables in the region and conform to the rated power specification.
CAUTION
The power source shall conform to the requirement of the Safety Extra Low Voltage (SELV) standard, and supply power with rated voltage which conforms to Limited power Source requirement according to IEC60950-1. Please note that the power supply requirements are subject to the device label.
CAUTION
The circuit breaker is a disconnection device. When using the circuit breaker, keep the angle for easy operation.
Warning Labels on the Device
Description Label Label Position
Danger electric shock
External surface of the
Device
Danger warning
Caution exercise
External surface of the
X-ray generator and X-ray controller
Danger radiation
Entrance&Exit of the
Device inspection tunnel
V
Description
Film safety
Label Label Position
Entrance&Exit of the
Device inspection tunnel
User’s Manual
Requirements of package placement.
Entrance&Exit of the
Device inspection tunnel
Forklift
Watch your hand.
This product and - if applicable - the supplied accessories too are marked with "CE" and comply therefore with the applicable harmonized
European standards.
2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the
European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see:
VI
Forklift entry point on the
Device enclosure.
Surface of the conveyor cover
Outer box label and nameplate.
Outer box label and nameplate.
Description http://www.recyclethis.info
.
Label Label Position
User’s Manual
VII
User’s Manual
Table of Contents
VIII
User’s Manual
IX
User’s Manual
X
User’s Manual
XI
User’s Manual
Part1: Product Introduction
1 Overview
Introduction
The intelligent security screening system is a new security screening device that uses X-ray to quickly inspect baggage and goods without opening the packages. The Device adopts advanced
X-ray image detection system, with efficient semiconductor detector, digital image processing technology, and computer image display technology, to provide users with an efficient, reliable and high-quality image processing system with service functions. The Device has a large HDD capacity that can store no less than 1 million high-definition images, with reliable intelligent recognition and alarm against prohibited goods, person-package linkage, image enhancement, network expansion and interconnection, automatic detection and maintenance, and other functions. In addition, its simple and user-friendly operation design makes the user operation more convenient and efficient.
It is suitable for the security screening of handbags, briefcases, mailing bags, express mails and small parcels. It is mainly used in the security screening of various scenes such as government office buildings, court, procuratorates, convention and exhibition centers, and large-scale events.
Functions
Supports using X-ray to generate images of packaged passing the conveyor, and check the shape and material composition of the items of the package.
Supports Image enhancement, such as high penetration, super enhancement, light, scanning.
Supports security screening mode, superimposed monitoring on the security screening interface and monitoring mode.
Supports the analysis of the scanned image, Al recognize the prohibited objects such as knife, liquid, spray-can, gun, lighter.
Supports setting danger level for prohibited objects and and can be linked with voice prompts, sound and light alarms, conveyor stop, etc.
Supports AI overlay on suspect objects. The AI overlay square moves with the package.
Supports storage of all test results and statistics into reports, which can be queried and exported through different categories and time periods.
2 Built-in cameras at the exit and entrance of the conveyor to monitor the entire security screening process.
Supports system abnormal alarm (including no HDD, storage failure, IP conflict, MAC conflict, etc.).
Supports HDD storage space management, etc.
Supports management of users and user groups.
1
User’s Manual
Supports system operation and maintenance management, such as searching log and online user search, and upgrading device.
Packing list
Refer to the following checklist to check the package. If you find device damage or component loss, contact the after-sales service.
No.
1
2
Item
Overall packing
Main body
Table 1-1 Checking list
Appearance
Packaging
Description
Obvious damage
Accidental impact
Accessories ( see packing list) Complete or not
Appearance
Model
Obvious damage
Whether consistent with the order contract
Whether the labels are torn off.
Labels on the Device
Do not tear off and discard the labels. Or the warranty to this Device will be compromised. You might be asked to provide the serial number of this Device when you call the after-sales service.
2
2
Dimensions and Structure
Dimensions
AI single-energy security screening machine (mm [inch])
User’s Manual
This section takes ISC-M5030A as an example. For the details of other models, see Appendix 1.
Cable Ports
Cable ports
3
User’s Manual
NO. Port Name
1
2
Fuse
Table 2-1 Description of External Cable Connection
Power port
Description
The fuse switch is on when it is in up position.
The Device can be normally powered on only when the switch is turned on.
Connect the power cable.
Model
The position of the fuse varies from different security screening machines, the real equipment shall prevail.
The position of the power port varies from different security screening machines, the real equipment shall prevail.
ALL
3
3
Power cable of the display screen
Alarm indicator cable
The machine is equipped with power cable for display screen.
Connect the alarm indicator device.
3
3
USB cable
HDMI video output cable
Network cable
Connect to mouse, PC keyboard, operation keyboard, USB flash,etc.
HDMI output port for connecting the output display.
Connect the Device to the Internet 3
In Figure 2-1, applicable models are as follows: ISC-M5030A/ISC-M6550A.
ALL means all models are applicable.
ALL(optional)
ALL, 2.
ALL
ALL
Indicators
Indicators on one side of the Device body are as follows. And the other side is the same.
4
Indicators (One side)
User’s Manual
There are two X-ray indicators (red) on the upper part of the Device. In working status, the red indicators are on when X-ray is triggered; the indicator lights are off when X-ray is turned off.
There are two power indicators (green) on the lower part of the Device. When the Device is started, the green indicators are on; when the Device is upgraded or fails, the green indicators flash.
Figure 2-3 takes Model ISC-M5030A as an example. As is shown in the figure, it is the baggage
entrance, and there are one power indicator and one X-ray generator indicator, which is the same at the exit.
5
Part2: Operator
3
Display and Control
Emergency Stop Button and Indicator
3.1.1
Emergency Stop Button
Emergency stop button
User’s Manual
3.1.2
Power Indicators
The power indicator shows whether the power of the Device is turned on. If the POWER green indicator is on, it indicates the power of the Device is connected.
Power Indicator
3.1.3
X-Ray Generator Indicator
X-Ray Generator Indicator is used for warning and displaying the X-Ray emission. If the X-Ray red indicator is on, it indicates X-Ray is emitting.
6
X-Ray indicator
3.1.4
Power Input
After the Device is connected to the power supply, dial the fuse upwards.
Power input
User’s Manual
3.1.5
Key Switch
After finishing power connection, pull the fuse upward, turn the key switch clockwise from OFF to
ON .
Power input
7
User’s Manual
3.1.6
Power Switch
After finishing power connection, pull the fuse upward, turn the key switch clockwise from OFF to
ON , press the power button, the button light is on, and the security screening machine is powered.
Power input
Operation Keyboard
Operation keyboard
8
3.2.1
Control Keys
NO.
1
Name
Function keys
Table 3-1 Special keyboard description
Description
For details of function keys on the special keyboard,
User’s Manual
2
3
4 forward, press the reverse rotation key to stop the conveyor.
Conveyor control keys : Stop rotating the rollers.
Custom function keys
Image processing keys
: Rotate the rollers forward. When the rollers are reversely rotating, press the forward rotation key to stop the conveyor.
Default function shortcuts
F1 : Light
F2 : Dark
F3 : High penetration
You can set different functions for F1, F2, and F3 as required.
In the live view pop-up window, F1 is OK, and F2 is Cancel.
For details of function keys on the special keyboard, see3.2.3Image
3.2.2
Function Keys
For details of function keys, see the following table.
Keys
Table 3-2 Description of function keys
Function Description
If there are relatively thin or small objects that are not easy to recognize in the scanned image, you can use this
Digital Zoom function to zoom in a local region of the scanned image.
There is a fixed square area, move the square to the image, the image inside the square will be enlarged for operators to further confirm the details.
Press this key for the first time to enable digital zoom with 2x zoom times.
Press this key for the second time to enable digital zoom with 4x zoom times.
Press this key for the third time to disable digital zoom.
9
Keys Function
Menu
User’s Manual
Description
Press this key on any menu interface to switch to the main menu interface.
Image
Management
Press this key on any menu interface to switch to the baggage search interface.
Function
Switch
Exit
New Line
Delete
Numeric keyboard is for number by default. Press this key to switch among numbers, lowercase letters, and uppercase letters in sequence.
Shift does not affect the input state of the local virtual keyboard of the server.
Press this key on any menu interface to switch to the live view interface. Exit all image enhancement states and effects of zooming in and zooming out (the default state is a color image with 1x zoom multiple)
In the live view interface, press this key to jump to a new line. (When in web logging in, after enter the username, press Tab to jump to password line.)
In the input interface, press the key to delete the input content.
Previous Bag
Next Bag
The previous image playback ends once the conveyor is restarted.
Click the key to see the previous image with fixed speed.
Click and hold for continuous playback.
The next image playback ends once the conveyor is restarted.
Press this key to play back the next image.
Press and hold this key to quickly play back next images.
Vertical Flip
Press this key to flipped upside down the image on the screen.
Image
Correction
Press this key to correct the image.
10
Keys
/
Function
Zoom in/out
User’s Manual
Description
Zoom in and out on the image with the default max zoom times of 8x, which can be modified to 64x.
After zooming in, the zoom times are displayed in the status bar, at the same time, the focus of the current zoomed-in region (the red square circled area) is displayed on the small map in the lower left corner.
After zooming in, you can move the focus position by pressing the direction keys on the keyboard, dragging the red square circled area on the small map, or dragging the image of real-time baggage area. The image of real-time baggage area can only be dragged when the conveyor stops.
You can drag the image border with the mouse or scroll the wheel to zoom in or out on the image.
Normal
(Screen
Adaptation)
If the image display is not 1x, press this key to change the image display scale to the original scale 1:1.
Direction
Keyboard
After zooming in, you can use these buttons to adjust the position of the zoomed-in region, including four directions: up, down, left, right.
Numeric
Keyboard
In text box, you can enter the corresponding numbers, uppercase and lowercase English letters by pressing 0–9 keys on the corresponding numeric keyboard. As is shown in the left picture.
In text box, after enter shift, 0 key on the numeric keyboard can be used as a space.
Enter: When F1 is used as the OK key, the function is the same as F1.
3.2.3
Image Processing Keys
After an image processing key is triggered, the corresponding processing result of the current image is displayed in the status bar. For details of image processing keys, see the following Table.
Keys
Table 3-3 Description of image processing keys
Function
Color/Black &
White
Description
Switch between color display and black & white display. Press this key once to display the image in black & white; Press it again to display the image in color.
11
Keys Function
Inverse Color
Super
Enhancement
Image Scan
High Penetration
User’s Manual
Description
Enable/disable image inverse color. Press this key once to achieve inverse color; press it again to exit the inverse color.
Enable/disable super image enhancement. Press this key once to start super enhancement; press it again to exit super enhancement.
It's used for displaying the result of scanned images under different absorption rate.
Press this key for the first time, and the absorption rate starts to decrease to the minimum value, and then starts to increase to the maximum value, for cycle display.
Press this key for the second time to stop the image transformation effect.
Press this key for the third time to exit the image scan state.
Enable/disable high penetration. Press this key to enable high/low energy image processing.
High Density Alert
Light
Enable/disable high density alert. Press this key to enable high density alert.
Pseudo Color
Edge Enhancement
Enable/disable image pseudo color.
Press this key to enable pseudo color; press it again to exit the function.
Enable/disable the image function of edge enhancement.
Press this key to enable edge enhancement; press it again to exit the function.
Enable/disable light.
Press this key to enable light; press it again to exit the function.
Dark
Enable/disable dark.
Press this key to enable dark; press it again to exit the function.
AI Single-energy Security screening machine does not include the following functions: Low penetration ; Organic Stripping
Density Threat AlertZ7/Z8/Z9.
; Inorganic Stripping ; Mixture Stripping ;
12
User’s Manual
4
Basic Operations
You must initialize the Device for first-time use, and do some basic settings such as data collection, display, and inspection.
Power on
Insert the plug of the power cable of the Device into the power supply socket to ensure that the power supply is normal.
After connecting the power cable, turn on the power switch (turn the fuse upwards) to turn on the Device.
Insert the key into the key socket in the upper left corner of the Device, and turn the key clockwise to the position "ON".
When the key switch is in the "ON" position, press this key to power on and start the system, the green indicator will be on and the Device will be powered on. The login in interface displays after the system startup animation ends.
Please make sure that the power cable has been connected to a power output socket with a protective grounding connection.
Before starting the Device, make sure that the supply voltage input meets the power supply requirements.
In order to ensure the stable operation of the equipment and prolong the service life of the hard disk drive (HDD), it is recommended that you refer to international standards and provide a power input with stable voltage value and low ripple interference; if the power supply is unstable, it is recommended to add a UPS.
To ensure the safety of the Device, connect the other cables of the device before turning on the power.
Login and Logout
This section introduces how to log in and log out in the case of one or two display monitors:
Logging in to local Interface: For first-time login or switching to a new user account, login in on one monitor, and then the other monitor logs insimultaneously.
Log out: Log out on one monitor and the other monitor logs out simultaneously.
4.2.1
Logging in
13
User’s Manual
By default, live view is only allowed after login in. If Live View Control is enabled in System
Settings > System Settings , the Live View interface can be displayed without login in.
This manual takes the live view after default login in as the example.
Power on the Device.
Local login
Enter the username and password.
The operator enters username and password.
Click Login .
Local security screening interface
14
User’s Manual
4.2.2
Logging out
At the lower-left corner of the live view interface , select the username in the login status, select Log Out , and then the system returns to the login interface.
Warming up
The device will perform self-test to automatically determine whether warm-up is required every time when it is started. X-ray generator warm-up can gradually increase the operating voltage, thus ensuring normal operation of the generator and extending its service life.
Log in to the system to perform self-test. If the Device is not used for a long time, the warm-up of the X-ray generator will be started.
Clear the tunnel
Clear the tunnel
Click / or press / on the operation keyboard, and the conveyor moves to the left or right to convey the items in the tunnel.
When all items are cleared from the tunnel, click or press on the operation keyboard to stop the conveyor.
Click OK . Warm-up of the X-ray generator starts.
Warm-up time varies from the intervals between power off last time and power on this time.
Warming up
15
Interval
0 Day < Y < 3 Days
3 Day < Y < 30 Days
30 Day < Y < 90 Days
Table 4-1 Description of warm-up time
Warm-up time
0 minutes
5 minutes
10 minutes
Y ≥ 90 days 50 minutes
The Image Correction interface is displayed after the warm-up ends.
Image correction
User’s Manual
Click Correction to finish image correction.
When the device is in normal use and the power-on interval does not exceed 3 days, the device is turned on normally. After the clear tunnel is displayed, directly enter the device correction interface. After the correction is completed, the live view interface is displayed (will not enter the warm-up process).
Object Placement
Scanned objects should be put stably on the conveyor or the roller table according to the object placement sign .
16
Object placement
User’s Manual
WARNING
The inspected objects must be placed outside the lead curtain! It is strictly forbidden to reach into the detection tunnel!
Avoid falling or accumulating the inspected objects at the exit of the equipment. Once it happens, stop the conveyor immediately.
Light and thin objects, dirty objects, or objects with damaged packaging need to be placed in a suitable plastic container for scanning.
Object Scanning
After logging in, operators finish system setting and warm-up. The system starts to scan the objects when it displays READY in the system status bar.
After pressing or , conveyor starts to work. Place the inspected objects in the center of the conveyor and it will pass through the tunnel along the conveyor.
According to the image of the inspected object, click the corresponding image function button on the operation keyboard to recognize image.
After the inspected object is moved out of the tunnel along the conveyor, click on the keyboard to stop the conveyor. When inspection is done, the scanned objects can be taken out or further inspected.
17
User’s Manual
Shut down
Before shutting, confirm that scanning is done and no objects on the tunnel.
Click on the operation keyboard to confirm the conveyor has been stopped.
When turning the key switch counterclockwise to the "OFF" state, the indicator on the right side of the key hole turns off, and the Device starts to shut down.
After Step 1, you can use the lower-left corner of the live view interface to select the
logged-in username, and select Shut to perform a soft shutdown of the Device. After the
soft shutdown ends, you still need to go back to Step 2.
As the Device needs to save scanned data and exit the operating system, do not immediately disconnect the external power supply of the Device.
Disconnect the external power supply only after the indicators on the machine are off and the shutdown is complete.
Remove the key from the operation keyboard and keep it in a safe place.
Basic Information Search
4.7.1
Baggage Search
Search and count all scanned baggage, and view relevant videos.
Procedures
Click on the homepage.
18
Homepage
User’s Manual
Select BAGGAGE MANAGEMENT > BAGGAGE SEARCH.
Baggage search
Set the query period, select the Category , enter Confidence , and then click Query .
The End Time must be later than the Start Time . The longest period for query is 30 days.
The default category is All . Types of item include guns, explosives, knives, lighter, spray cans, liquid, electronic products, umbrellas, brass knuckles, handcuffs, nightsticks and uncategorized items.
19
Baggage search results: single view
User’s Manual
①
Single-view security screening machine: only single picture display
Related Operations
View recordings: See Figure 4-8 Baggage search, select queried pictures and click
in the square ① on the left side of the interface to play the recordings linked with the baggage 10s before and after the baggage passes the screening machine.
The associated recording channel has been configured. For more details, see 8.3.6Security
Screening. The first installation administrator setup is completed by the admin.
View details: Click a queried picture and the system displays the baggage details.
Baggage details
20
User’s Manual
Operators only have the access to Query and cannot Export . Click Export , and it will display a prompt No access .
4.7.2
Report Search
Select BAGGAGE MANAGEMENT > REPORT SEARCH .
Report search
Set the query period, select the category of item, and then click Query .
Line chart
Click Data and the system displays data in the form of report.
Report
21
User’s Manual
Operators only have the access to Query and cannot Export . Click Export , and it will display a prompt No access .
22
5
Image Processing and Live View
User’s Manual
Live View
The live view interface can be set as Security Screening Mode or Monitoring Mode as needed.
For more details, see Part3 Administration 9.5.3Display Output. The mode is set by the
administrator before the Device leaving the factory.
Security Screening Mode
After setting the prohibited items recognition strategy, you can view the detection images and snapshots of suspect items on the live view interface. The software interface has the same image and operation function icons as the operation keyboard, which achieves same functions. For more
details, see 3.2.2Function keys and 3.2.3Image Processing Keys.
Security screening mode
NO. Name
Table 5-1 Security screening mode interface description
Description
Real-time baggage Scroll display the live scanning image from the Device. For more details,
1 area
2
3
Baggage thumbnail
Login user
The baggage thumbnail displays the position of the current preview screen in the overall screen.
After overall zoom, the tracking square is used to display the position of the current screen in the overall area. The tracking square is red in the playback state, and blue in the real-time package scanning state.
Click this icon and you can modify user password, lock down user, log out, reboot or turn off the Device.
23
User’s Manual
NO.
4
5
6
7
8
9
10
Name
Baggage statistics
Zoom in times
Custom functions(F1/F2/F3 custom function keys)
Scan direction:
Conveyor status
Device working status
Image enhancement button
Description
Display the number of temporary baggages(the statistics starts from the
Device is powered on) or the number of cumulative baggages (the statistics starts from the Device leaves the factory).
Display zoom in times. The default maximum zoom-in is 8 times, and the maximum zoom-in is 64 times.
Click this icon to enhance the configured images. For details,
This icon corresponds to the functions of F1, F2, and F3 keys on the keyboard.
Set scan direction on the screen. It supports single direction scan.
Display the current movement direction of the Device conveyor.
It displays the working status of the Device (normal/fault).
Preparation: Device powering on and warm up
Correction: Device correcting
Diagnosis: Device diagnosing
Ready: When the software is running and the conveyor is not started,
Ready is displayed. Meanwhile, if force scan is enabled, Ready [C] is displayed.
Waiting for scanning: The rollers rotates, no baggage on the conveyor.
Scanning: The rollers rotates and X-ray starts to scan the baggage.
Continuous scanning: Force scan starts and the roller rotates.
Stop: Stop the conveyor.
Up to 12 image enhancement buttons are displayed on the interface by default. You can modify the display of buttons in the display output configuration. Default configurations: energy enhancement, light,dark, pseudo color, scanning, edge enhancement, super enhancement, color/ black & white, inverse color, organic stripping, vertical flip, image
correction. For details, see5.3Image Processing.
Place the mouse cursor over the icon to display the corresponding function name. See 3.2.3 Image Processing Keys.
The display of image enhancement buttons is related to the screen resolution.
1080P: 12 function icons are displayed in the same row on the interface.
1280*1024: 12 function icons are displayed in two rows. The first six
11
Image enhancement status bar functions are displayed in order on the interface. Click to pop up the list of the other six functions.
Display image enhancement status. When there is an fault of the Device function, the fault information prompt will be displayed.
24
User’s Manual
NO.
12
Name
Conveyor control buttons
Description
: Conveyor rotates backward
: Stop the conveyor
13
14
System time
Menu
: Conveyor rotates forward
Display the current time of the operating system.
Click this icon to enter the setting interface.
Enter the setting interface, network, alarm, storage, user and basic system setting can be set.
Enter the setting interface, click LIVE in the upper left corner to return to the the live view interface.
Display the number of the notification. Click to see all the notifications.
The button displays the total number of the current notifications. If the number is 0, the window is hidden.
Click the notification bar to view all the notifications.You can also view three types of messages by classification ( system error ) ,
15 Notification bar
( system warning), ( system notification).
After the notification bar is unfolded, it will retract if the cursor leaves for 3s. Click the lock button to prevent the message bar from automatically retracting. You can manually close it by clicking .
16
17
Previous and Next
Click to delete an alarm message. Click to clear all the notifications.
You can view the last 30 baggage images after startup. Click the previous icon to see the previous image with fixed speed; Click the next icon to see the next image with fixed speed; Click and hold for continuous playback.
AI overlay switch
This function can also be used by clicking operation keyboard.
, keys on the
Click this icon to enable/disable the AI overlay square of the prohibited objects, and configure whether to display item name, text background, and similarity. Click this icon to turn on/ turn off this function.
25
User’s Manual
Notification bar
Image enhancement button(1080P)
Image enhancement button (1280× 1024 )
Type
Displayed content
Danger level
Table 5-2 Description of the real-time baggage area display
Description
For every suspect item, its type and confidence level are displayed by default.
You can set whether to display the type and confidence level in AI Overlay.
Click
to configure whether to display item name, text background and similarity, disabled by default.
If several prohibited items exist in the same bag, the danger level is judged according to the item with the highest danger level. For example, if a bag has both high risk items and safe items, the bag image is displayed on the high risk area on the left of the scanned baggage records.
The background color of prohibited item images means the danger level:
Red: High risk
Orange: Warning
Dark gray: Safe
Light gray: Unclassified
26
User’s Manual
Image Processing
5.3.1
Image Enhancement
Image processing function area interface Image processing functions can be operated not only on the software interface, but also directly through the special keyboard of the Device.
Image enhancement
Click an icon for the first time, the image is highlighted; click the icon again, the image is not highlighted. The image is colored by default.
Image enhancement takes effects on the whole baggage area. All image enhancement functions take effects in the real-time baggage area whether the baggage normally passes or not.
Image enhancement only takes effects for security security screening mode. If the security screening mode is an auto mode, the image enhancement key takes effect. If it is custom mode (such as black & white mode; custom mode can be set in the display output configuration), the image enhancement key does not take effect.
Click to select image enhancement function, and click again to cancel the corresponding image enhancement functions. Image enhancement functions can also be canceled by
on the operation keyboard.
5.3.1.1
Color/Black & white
The color images not only show the absorption of X-ray by substances, but also show the material composition of the substances. To better identify dangerous items, scanned objects will be categorized into organic substance, mixture and inorganic substance, and marked in orange, green and blue respectively according to their composition for easier recognition to operators.
The brightness of each color corresponds to the thickness and density of the substances. The thicker the substances and the greater the density, the darker the colors.
The image is displayed in color by default. Click Color/Black & White icon or press special keyboard to switch between color image and gray image.
on the
27
Comparison of color image and black & white image
User’s Manual
5.3.1.2
Partial Enhancement
Partial enhancement can brighten darker areas in the image, so that the objects hidden behind thick objects can be clearly displayed without affecting normal image areas.
In normal image display, click to switch the image to partial enhancement state; click the icon again to return the image to normal display state.
Color image/image partial enhancement (partial enhancement)
5.3.1.3
Super Enhancement
Through super enhancement, the images of penetrable objects (such as clothing and silk threads) and impenetrable objects (such as thick metal plates and frozen products) can be clearly displayed on the screen at the same time. Even low-density materials (such as clothing) hidden between the metal plates are clearly visible.
As a comprehensive image processing function, super enhancement obtains the best contrast of each point in the image, the best image details and edge information through the calculation and statistics of the contrast of each small image area.
During image display, click the Super Enhancement icon or press on the special keyboard to enhance details of the image, so that the objects hidden behind thick objects can be clearly displayed. Click the icon or press the key to display the image in super enhancement state. Click the icon or press the key again (or press ESC ) to end super enhancement.
28
Color image/image super enhancement (super enhancement)
User’s Manual
5.3.1.4
Edge Enhancement
Compared with the default original image effect, the edge enhancement function enhances the edges display in the image, especially the display of weak edges, making the structure and contour information in the image more prominent and clear.
During image display, click to enable edge enhancement. Click the icon or press the key again (or press ESC ) to end edge enhancement.
Color image/Image edge enhancement
5.3.1.5
Image Scan
Image scan function separately displays the details of objects with different material thicknesses in the image. After enabled, the function periodically changes the absorption rate of the object image to observe details of each part of the image, with a certain contrast reserved outside the range of absorption rate. You can observe the whole image of the scanned object at any level.
During image display, click the Image Scan icon or press on the special keyboard, the image automatically changes among different absorption rates for you to observe details of each part of the image. The set level is 50 (cycle change within the range of -25–25).
Click the icon or press the key for the first time to start cycle change.
Click the icon or press the key for the second time to stop cycle change.
Click the icon or press the key for the third time to exit the image effect.
29
Figure 4-11 Color image/image scan
User’s Manual
5.3.1.6
Inverse Color
Inverse color function is used to check thin high-density objects (such as metal wires) with an effect similar to the negative film. The function displays objects with high absorption rate in bright colors and objects with low absorption rate in dark colors without changing the current color tone.
During image display, click the Inverse color icon or press on the special keyboard, to display objects with high X-ray absorption rate in bright white and objects with low X-ray absorption rate in dark black, making small or thin high-density objects (such as metal wires) more clearly visible. It is the opposite in white inverse display.
Color image /Image inverse color
5.3.1.7
Energy Enhancement
The function of high penetration is used to highlight details in the dark areas of the image. These dark areas correspond to impenetrable substances with high X-ray absorption rate, which usually have high density (such as lead and steel) or large thickness.
This function helps to analyze details in the dark areas of the image, so that hazardous goods hidden inside impenetrable objects can be inspected, while penetrable objects are hidden or faintly displayed.
During image display, click the High Penetration icon or press enable this function.
on the special keyboard to
30
User’s Manual
Color image/high penetration
5.3.1.8
Light/Dark
During image display, click or again to restore normal image display.
to lighten or darken the entire image. Click the icon
Color image/Light
Color image/dark
5.3.1.9
High Density Alert
During image display, click the High Density Alert icon to display the impenetrable areas in the images of inspected objects in red.
Color image/high density alert for suspect image
31
User’s Manual
5.3.1.10
Zoom in/out
To display the image more clearly, you can use the global zoom function. This function can zoom in on the scanned image as a whole, so that the operator can carefully recognize every detail of the image.
During image display, click the Zoom in or Zoom out icon or press
keyboard to zoom in or zoom out. For zoom-in display, see Figure 5-16.
/ on the special
After zooming in by using the global zoom function, use the mouse or press the direction keys on the special keyboard to drag the image for recognition. At the same time, there is a thumbnail of the zoomed image at the lower right corner. When zooming in, there is a black square that marks the image area currently displayed in full screen.
You can scroll the mouse wheel to zoom in or out on the image.
Smooth zoom in for each zoom-in, with up to 64x.
Smooth zoom in for each zoom-in, with at least 1x.
Press on the special keyboard for adapted screen display.
When zooming in, press the direction keys of up , down , left , right
on the special keyboard, and the image will automatically zoom in by 2x and move to the corresponding direction.
Zoom in
5.3.1.11
Pseudo Color
During image display, click , and the image on the screen will change accordingly. The pseudo color image displays rich details, thus helping the operator to recognize details of the image.
32
Color image/pseudo color processing
User’s Manual
5.3.1.12
Vertical Flip
During image display, click , and the image on the screen is flipped upside down, thus helping the operator to recognize objects of different shapes.
Vertical flip
5.3.1.13
AI Overlay
Click on the right side of the AI Overlay icon, and then select information to be displayed on the live view interface, including object name, text background, similarity, and package box. After selection, the corresponding information is displayed on the live view interface.
AI Overlay setting
During image display, click the AI Overlay icon to enable this function to close the package box, object name, text background, and similarity on the live view interface. Click the icon again to disable this function and open information display on the live view interface.
33
AI overlay
User’s Manual
5.3.2
Image Correction
During long-term and continuous scanning of scanned objects, the interval of which is too small
(smaller than 20 cm), the image quality becomes poor due to minor changes in the parameters of the X-ray generator. Enable image correction to improve image quality.
During image display, click to correct the image. Click the icon again, and then select
Continue Correction or Cancel in the prompt box.
The correction process cannot be canceled upon the first startup, but can be canceled during normal use after startup.
During correction, click the conveyor control button or the corresponding control key on the special keyboard to control the conveyor, ensuring that the tunnel is cleared.
During image correction, the system will automatically determine whether there are packages left in the tunnel. If yes, check the tunnel and ensure it is cleared before connection.
34
User’s Manual
5.3.3
Force Scan
Disabled by default.
The function of force scan is used to detect and recognize ultra-thin objects.
Click Force Scan icon or press on the special keyboard to enable this function, the X-ray works continuously once the conveyor is started. Click the icon or press the key again to disable force scan. After the function is disabled, the X-ray is triggered only when the conveyor is started and an object passes the IR sensor.
Monitoring Mode
According to the settings of monitoring mode, live views of the linked channels are displayed.
Monitoring mode
Manual snapshot: Point to the video window, and click to capture pictures.
Manual recording: Point to the video window, click and the system starts recording. The length of the recording is displayed at the upper-left corner of the video window; click again and the recording stops.
35
User’s Manual
6
Maintenance
Routine maintenance must be carried out during system operation in a prevention-oriented principle. It is one of the important links to use and operate the system in a reasonable manner.
Cleaning External Surface of the Device
During long-term operation of the Device, there will be dust and dirt on its external surface. To ensure normal operation, the external surface of the Device shall be regularly cleaned.
Use a slightly damp towel to clean the external surface of the Device.
Clean the enclosure and pole of the Device.
Before cleaning the external surface of the Device, you need to turn off the power and disconnect the Device from the external power supply.
Cleaning IR Sensor on Conveyor Side
The IR sensor is blocked or clogged. After the conveyor ③ is started, the Device immediately generates X-ray for scanning. Check the system settings, if Force Scan is not enabled, the IR sensor might be blocked or clogged.
Turn off the Device, and then remove the special keyboard key and carry it with you. Check the IR sensor status. The IR sensor is located on the inner wall ① of the tunnel inside the lead curtain.
Check whether the IR sensor is blocked, which affects its signal accuracy. You can gently clean the
IR sensor surface with slightly damp cotton balls.
Cleaning IR sensor on the conveyor side.
①
②
③
36
User’s Manual
Cleaning Display Screen
During long-term operation of the Device, there will be dust or fingerprints on the display surface, affecting the resolution of the object image to be judged by the operator. You can use special detergent for display to clean the screen when the display is powered off and then adjust its brightness.
Inspecting Conveyor
During long-term inspection, the conveyor might deviate from the tunnel center. If the motor side is exposed due to the left or right deviation of the conveyor, the conveyor needs to be adjusted.
Contact professional maintenance personnel to adjust the operation status of the conveyor, or carefully read the maintenance manual.
Inspecting the Lead Curtain at Tunnel Entrance and
Exit.
If the lead curtain has large gaps, falls off or is damaged, contact professional maintenance personnel to replace or repair it.
Before inspecting the lead curtain, the Device should be powered off. And the operator must wear gloves when adjusting the lead curtain.
Inspecting X-ray and Power Indicator
The system administrator and maintenance personnel can inspect the X-ray indicator status through corresponding operations in the diagnosis and maintenance program.
Emergency Stop Button
The emergency stop buttons on the Device enclosure and console are key safety Devices. If the switch is loose or the enclosure is damaged, immediately stop the Device, and contact professional maintenance personnel to maintain or replace the corresponding emergency stop button. The
Device cannot be used until the button is repaired.
After maintenance, press the emergency stop button. At this point, if the motor inside the system stops rotating and the X-ray generator stops generating X-ray, and a prompt will appear on the
37
User’s Manual screen that an emergency stop button is pressed is displayed, it means that the button works normally.
38
User’s Manual
7
FAQ1
When the key switch is turned on and the power button is pressed, the indicator doesn't work and the Device cannot be powered on
Possible cause
The power cable plug of the Device is loose.
The circuit breaker at the power input end is not closed or the fuse is open.
Troubleshooting:
1.
Please first check whether the power cable plug of the Device has been inserted into the power socket normally or not. If the plug is loose, please reinsert it.
2.
Use tools to open the enclosure where the circuit breaker and fuse are installed on the equipment, check whether the circuit breaker is off and whether the fuse is on. If the fuse is burned out, replace the Device with components of the same specification.
3.
Rotate the key switch on the Device again, if the indicator on the right is on, the Device can be started, and the fault is eliminated.
Troubleshooting:
The position of the power supply and the circuit breaker vary from models. If the errors cannot be eliminated according to the above steps, please contact professional maintenance personnel.
39
User’s Manual
No generated images on the display screen
Possible cause:
Power switch of the display screen is off;
Power plug of the display screen is loose;
HDMI cable of the display screen is loose.
Troubleshooting:
1.
Please check the power switch of the display screen to confirm the switch is on and the indicator lights up at this time.
2.
Please check whether the display screen cable plug is loose or not. If there is a problem, please reinsert it and rotate the screws on both sides of the plug to make it firm.
3.
Observe the display screen, if the image is generated, the fault is eliminated.
If the errors cannot be eliminated according to the above steps, please contact professional maintenance personnel.
Conveyor doesn’t work
Click
Possible cause:
or , but the conveyor doesn’t work.
The emergency stop button is pressed by mistake or the safety interlock is triggered by mistake.
Troubleshooting procudures:
1.
Please check whether the system status bar displays the prompt Emergency stop button is triggered . If this prompt appears, follow the steps below to deal with it.
2.
Check the emergency stop button of the equipment enclosure. If any switch is found to be pressed down, please turn it clockwise to reset.
3.
Observe whether the Emergency stop button is triggered prompt on the system status bar disappears. If it disappeared, press the conveyor control button again, and the conveyor starts to run. If the message Security inspection machine enclosure is open appears, please follow the steps below again deal with.
4.
Check whether the equipment enclosure is installed in place one by one. If any enclosure is found to be loose, please fix and install it again.
5.
Observe whether the message Security screening machine enclosure is open on the system status bar disappears. If it disappeared, press the conveyor control button again, and the conveyor starts running.
40
User’s Manual
The positions and numbers of emergency stop switches vary from different types of security screening machine.
If the errors cannot be eliminated according to the above steps, please contact professional maintenance personnel.
Device automatically power off during running.
When the Device is running, the display suddenly goes black and the power indicator of the
Device goes out.
Possible cause:
The external power supply of the device is loose, and the circuit breaker or fuse is disconnected.
Troubleshooting:
1.
Please check whether the external power cable plug and power socket of the equipment are loose or not.
2.
If there is no abnormality in the external power supply of the equipment, you need to check whether the equipment circuit breaker or fuse is disconnected, use a tool to open the enclosure where the circuit breaker and fuse are installed on the equipment, and check whether the circuit breaker is off or whether the fuse is complete.
If the errors cannot be eliminated according to the above steps, please contact professional maintenance personnel.
If the errors are not covered by this manual, please contact professional maintenance personnel.
Part3: Administrator
8
Daily Operations
Basic Settings
8.1.1
Device Initialization
41
User’s Manual
When starting the Device for the first time or restoring factory defaults, you shall set the login password of the administrator account ("admin " by default), and the time zone and time. You can set the password protection method as necessary.
Do not power off the Device during initialization.
Power on the Device.
Read and click I agree the agreement to agree, and then click Device initialization .
Time
Select the Time Zone and Date/Time , and then click Next .
Device initialization
Parameter
User
Set the admin login password and configure the parameters.
Table 8-1 Descriptions of password setting parameters
Description
The default username is admin.
42
Parameter
User’s Manual
Description
The password should consist of 8 to 32 non-blank characters and contain at least two types of characters among upper case, lower case, number, and special characters ( excluding“'”,“"”,“;”,“:”,“&” ) . Please set a high-security password according to the password strength prompt. Password
Confirm password
Enter the password, press and hold , and the password becomes visible.
Release the left mouse button or move the mouse pointer elsewhere, and the password become invisible again.
Prompt
After setting the Prompt Question , move the mouse pointer over on the question login interface. The system displays the prompt question you have set to help you recall the password.
Click Next.
Password protection
Set password protection. For more details, see Table 8-2.
After setting password protection, you can reset the admin login password by using
reserved email or security question if the password is lost. For details, see 9.6.3.4Resetting
Click to disable the setup of the Reserved Email and Security Questions if you do not want to set password protection.
Table 8-2 Password protection description
43
User’s Manual
Password
Protection
Method
Description
Reserved email
Set reserved email. To reset the admin login password, you need to scan the QR code, then type the security code the reserved email received.
After the setup, you can modify the reserved email on the Attribute interface.
For details, see 9.6.3.2 Modifying User.
Set the security questions and answers. Provide correct answers to the security Security questions questions and you can reset the admin password.
Click Finish .
Click Enter Quick Settings to set the basic information of the Device. For more details, see
Initialization completion interface
8.1.2
Quick Configuration
After the Device is initialized, you can quickly set the IP address on Quick Configuration interface .
On the Successfully initialized the device interface, click Enter Quick Settings
44
IP setting
User’s Manual
Set IP address
Only 1 Ethernet Port of the equipment. Before setting IP address, confirm the ethernet port has already connected to the Internet.
1) Click the icon corresponding to the network port.
2) Parameter
Parameter
Speed
Use dynamic IP address
Use static IP address
Table 8-3 Descriptions of NIC editing
Description
Maximum network transmission speed of current NIC.
When there is a DHCP server on the network, select the check box to use dynamic IP address. System can distribute a dynamic IP address to the Device.
There is no need to set IP address manually.
Set static IP address, subnet mask and gateway. It is to set a static IP address for the Device.
Set NIC MTU value. The default setup is 1500 Byte.
We recommend that you check the MTU value of the gateway first and then set the device MTU value equal to or smaller than the gateway value. It is to reduce the packets slightly and enhance network transmission efficiency.
MTU
Changing MTU value might result in NIC reboot, network offline and affect current running operation. Be careful.
3) Click OK .
4) The system returns to the IP Set interface.
Set DNS Server parameters.
You can select to obtain the DNS server address automatically or manually enter.
45
User’s Manual
When activating the domain name service, this step must not be skipped.
Obtain DNS server address automatically: Select Obtain DNS server address automatically , and then the system automatically gets the IP address of the DNS server.
Use the following DNS server address: Select Use the following DNS server address , and then you need to enter the IP address of the preferred DNS and the alternate
DNS.
Set the default NIC
Select Default Ethernet from the Default NIC drop-down list as needed.
Only NIC which has been connected to the network can be used as the Default NIC.
Click Finish .
Login and Logout
This section introduces how to log in and log out in the case of one or two display monitors:
Logging in to Local Interface: For first-time login or switching to a new user account, login in on one monitor, and then the other monitor logs in simultaneously.
Log out: Log out on one monitor and the other monitor logs out simultaneously.
8.2.1
Logging in to Local Interface
By default, live view is only allowed after login in. If Live View Control is enabled in System
Settings > System Settings , the Live View interface can be displayed without login in.
This manual takes the live view after default login in as the example.
Power on the Device.
Local login
46
User’s Manual
Enter the username and password.
The default username is admin and the password is the login password set during device initialization. To keep the Device safe, we recommend you to modify the
admin password regularly and properly keep new passwords.
If the login password of the admin account is lost, click Forgot Password?
And then
reset the admin password. For details, see 9.6.3.4Resetting Admin Password.
Click Login .
Local security screening interface
8.2.2
Login in to Web Interface
You can use Google Chrome, Firefox, or other browsers to log in to the web interface, and then you can set up and operate the Device, and maintain the system.
When using a general browser to log in to the web interface, you can only set up the Device, but cannot play live view. We recommend you to play the live view of the real-time security screening video through the local interface.
We recommend you to operate in the local interface.
Open the browser, enter the IP address of the Device, and press Enter.
47
WEB logging in interface
User’s Manual
Enter the username and password.
The default username is admin and the password is the login password set during
device initialization. To keep the Device safe, we recommend you to modify the admin password regularly and properly keep new passwords.
If the login password of the admin account is lost, click Forgot Password?
And then
reset the admin password. For details, see9.6.3.4Resetting Admin Password.
Click Login .
8.2.3
Logging out
At the lower-left corner of the live view interface , select the username in the login status, select Log Out , and then the system returns to the login interface.
Baggage Statistics
8.3.1
Baggage Search
Search and count all scanned baggage, and view relevant videos.
Procedures
Click on the homepage.
48
Homepage
User’s Manual
Select BAGGAGE MANAGEMENT > BAGGAGE SEARCH.
Baggage search
Set the query period, select the Category , enter Confidence , and then click Query .
The End Time must be later than the Start Time . The longest period for query is 30 days.
The default category is null. Query is possible only after selecting a specific category.
Types of item include guns, explosives, knives, lighter, spray cans, liquid, electronic products, umbrellas, brass knuckles, handcuffs, nightsticks and uncategorized items.
49
Baggage search results
User’s Manual
Single-view security screening machine: only single picture display
Related Operations
View recordings: Select queried pictures and click on the left to play the recordings linked with the baggage 10s before and after the baggage passes the screening machine.
Prerequisite: The associated recording channel has been configured. For more details, see
View details: Click a queried picture and the system displays the baggage details.
Baggage details
50
User’s Manual
Export Checked Items: Select the baggage information to be exported, and click
Export Checked Items to export selected information; enter the password of the current account on the pop-up window to export checked items to local.
Export All: Click Export All to export all information of queried baggage. Enter the password of the current account on the pop-up window to export checked items to local.
If entering the wrong password 5 times continuously, the device will jump to the login interface.
Only user groups configured with the File Backup permission can export
package files. For how to configure user group permissions, see 9.6.3.1 Adding
8.3.2
Report Search
Support baggage data statistics and displaying data in the form of line chart or report.
Procedures
Select BAGGAGE MANAGEMENT > REPORT SEARCH .
Report search
Set the query period, select the category of item, and then click Query .
Line chart
51
Click Data and the system displays data in the form of report.
Report
User’s Manual
Related Operations
Export data:
Click Export Picture to export the line chart.
Click Export Report to export data reports.
8.3.3
Voice Broadcast
Configure the port, voice file, and broadcast rules for voice broadcast. The settings come into effect immediately.
8.3.3.1
Uploading Voice File
Select BAGGAGE MANAGEMENT > VOICE BROADCAST .
Voice broadcast
Click Upload Voice File and then select voice files to upload.
52
User’s Manual
Uploaded voice files are displayed in the list. Click file.
to make an audition of this voice
Voice files are in MP3 format only. A single voice file shall not exceed 32 MB. Up to 50 voice files can be uploaded, provided that the total size does not exceed 200 M.
The Capacity at upper-right corner shows the total capacity of uploaded voice files.
A voice file cannot be deleted if a test voice file is being played.
8.3.3.2
Configuring Voice Broadcast
You can use different voice files to be broadcast in different periods.
Voice Broadcast Rules
Use of Audio Ports
Broadcast and alarm share the same audio port
Audition file is activated when broadcast or alarm is playing
Table 8-4 Voice broadcast rules
Audio Broadcast Rules
The alarm has higher priority than the broadcast at the same playing period.
When the current broadcast is being played and an alarm comes in, the broadcast stops. After the alarm ends, the broadcast does not resume playing, but waits until the next play interval comes.
When an alarm is being played and a broadcast comes in, the alarm continues, and the broadcast is not played.
When broadcasts and alarms are in queue, use the queue strategy.
When a broadcast is being played and another comes in, the latter waits in queue.
When an alarm is being played and another comes in, the latter waits in queue.
If you activate audition file when a broadcast or alarm is being played, the audition file prevails. After the audition file, the interrupted broadcast or alarm does not resume playing.
Priority of play: Audition file > Alarm > Broadcast .
There is only one audio port in the single-energy security screening machine.
Procedures
Select BAGGAGE MANAGEMENT > VOICE BROADCAST .
53
Voice broadcast
User’s Manual
Set the output ports corresponding to broadcast and alarm events.
Set the volume.
Volume 1 corresponds to Output Port 1.
Click Broadcast .
Voice broadcast
Set voice broadcast parameters
The periods between two voice broadcasts cannot be overlaid.
Parameter
Enabled
Start time, End time
Voice file
Table 8-5 Set voice broadcast parameters
Description
Enable the voice broadcast.
Set the broadcast period in 24-hour format.
Select uploaded voice files.
54
Parameter
Interval
User’s Manual
Description
In the preset period, the interval between repeated playback of the corresponding voice file is in seconds.
The range is from 5 s to 600 s.
The number of times for repeatedly playing a voice file in each period.
The upper limit is 5.
Cycle times
Click OK .
Related Operations
Edit: Click corresponding to the voice broadcast and you can edit this broadcast.
Delete: Click corresponding to the voice broadcast and you can delete this broadcast.
8.3.4
Configuring Detection Parameters
Configure the detection of multiple suspect items, and set the linkage alarm when the device detects the corresponding item.
Select BAGGAGE MANAGEMENT > DETECTION CONFIG > Analysis .
AI Analysis
Set AI Analysis rules.
Parameter
Sensitivity
Smart Plan
Click Save .
Table 8-6 AI Analysis Parameters Description
Description
The higher the sensitivity, the easier the suspect items are detected.
Select a smart plan as required.
8.3.5
Configuring Suspect Item
Default suspect items vary according to different algorithm models. You can modify the suspect item as needed.
55
Select BAGGAGE MANAGEMENT > DETECTION CONFIG > SUSPECT ITEM .
Suspect Item
User’s Manual
Enable the item detection as needed.
means enabled; means disabled.
In the list, click corresponding to the suspect items.
Modification
Configuring suspect iem.
Parameter
Enabled
Danger level
Alarm output
Table 8-7 Descriptions of suspect item parameters
Description
The Device starts detecting these items when they are enabled.
The danger level of suspect items.
Connect an external alarm device (such as an alarm light or siren) to the alarm output port. Select the checkbox, set the alarm output device, and activate the alarm action output port. When an alarm event takes place, the system can associate with corresponding alarm output devices.
56
Parameter
Alarm Delay
Voice prompt
Conveyor
Report to platform
Similarity
Click OK .
User’s Manual
Description
After the alarm event ends, the alarm will be extended for a period of time to stop.
The range is from 0 s to 300 s.
Enable voice prompt, and select the corresponding voice file in the drop-down list of File Name . When an alarm event takes place, the system plays selected voice file.
Make sure the corresponding voice file is added. For how to upload voice
files, see 8.3.3Voice Broadcast.
If multiple voice alarms are triggered simultaneously, the previously triggered voice broadcast must finish playing before the next starts playing. After the previous voice broadcast is played, if several broadcasts are in queue, only play the newest.
Set the working mode of linkage conveyor after configuring the detection of such suspect items, normal linkage mode and stop mode are available.
When this function is enabled, information of suspect items is reported to associated platforms.
Before using this function, make sure the Device is already added to the platform.
When the confidence level of the scanned items is equal to or greater than the preset value, the system reports this alarm information to the platform.
8.3.6
Security Screening
Select the camera channelof the baggage entrance and baggage exit based on the specific installation of cameras.
The camera at the baggage entrance is pointed at the baggage entrance of the equipment to monitor the flow of people and baggage; the camera at the baggage exit is pointed at the baggage exit of the equipment to monitor the flow of people and baggage. When inquiring about baggage, person-package linkage function can be used.
Select BAGGAGE MANAGEMENT > SECURITY SCREENING.
57
Security screening
User’s Manual
Settings of security screening business parameters.
Parameter
Table 8-8 Description of security screening parameters
Description
Select to enable the power saving mode. When the mode is enabled, if no new
Power Saving Mode
High Density Alert
Vertical Flip
Max Zoom Times packages are placed on the conveyor within 15s, the conveyor will automatically stop until packages are placed on it again.
After selection, when thick impenetrable objects are detected, the objects in the image are displayed in red.
After selection, the live view of packages is vertically flipped to help recognize objects of different shapes.
Set the max zoom times of the detection image, which is 8x by default and up to 64x is supported.
58
User’s Manual
Parameter
Scan Direction
Description
Set the scan direction of the Device. You can select dual-direction, forward scan or reverse scan.
Dual direction: The scanned object enters the tunnel from the package entrance/exit port of the Device, and the package will be displayed in pictures.
Forward scan: When the scanned object enters the tunnel from the baggage entrance of the Device, it will trigger the X-ray to scan the package. When it enters the tunnel from the baggage exit, it will not trigger the X-ray.
Reverse scan: When the scanned object enters the tunnel from the bag exit of the Device, it will trigger the X-ray to scan package. When it enters the tunnel from the bag entrance, it will not trigger the X-ray.
The baggage entrance is the tunnel entrance away from the nameplate label.
Camera for Bag
Entrance
Camera for Bag Exit
Click Setting .
Set the cameras corresponding to the bag entrance and bag exit.
Click to review the live videos of corresponding camera channels.
Baggage statistics:
Settings of package statistics parameters
Parameter
Table 8-9 Description of package statistics parameters
Setting Status Bar
Description
Select to display accumulated number of packages or number of temporary packages.
Restoring the number of temporary package
After enabled, the counter will be reset after logging in to the Device again. when logging in
(Optional) Click Counter Reset to clear the number of temporary packages.
Click OK to save the package statistics parameters.
Click Save .
59
User’s Manual
Video Playback
You can search and play back recordings or pictures stored in the Device, and export recordings or pictures to a specified location.
8.4.1
Playback
Search and play back recordings by camera, recording type, and recording time.
Click on the homepage.
Select PLAYBACK . The system displays the Video Playback interface,
Playback (1)
Select camera on the left, and click the Record below.
Select the recording type and stream type.
Types of recording include all record, manual record, video detection, and IO alarm.
All record: Search all recordings.
Manual record: Search manual recordings by the user.
Video detection: Search linked video detection recordings.
IO alarm: Search linked local alarm recordings.
Query time is set by the following methods:
Method A: Click the date or time in the time frame to modify date or time value.
Method B: Click the date or time in the time frame, rotate the mouse wheel to adjust date or time values.
Method C: Click , set date and time on the displayed calendar, and then click OK .
On the calendar interface, if a date is underlined by dots (such as ), meaning this date has recordings.
60
Calendar interface
User’s Manual
Click Search .
The system displays the query results. The thumbnails of recordings are displayed at the top of the interface, and the periods of recordings are displayed on the time bar (green means recordings exist).
The list at the left side displays the selected cameras. Click a camera and the corresponding thumbnail of recordings is displayed at the right side.
Click or to display the hidden thumbnails.
Point to the thumbnail to view information of the corresponding recording including the name of the camera storing this file, start time and end time of the recording.
Recording query results
Drag the thumbnail to the play window, or double-click the thumbnail.
The system starts playing back the recording. For more details about the description of
playback icons, see Figure 8-10
61
User’s Manual
Icon
The number of playback windows depends on the number of dragged or selected thumbnails. Up to 16 windows can be selected. The system automatically adjusts the size of each playback window based on the original scale of played-back recordings.
Table 8-10 Description of playback control icons
Description
Click the icon to switch to operation synchronization mode. Then you can control multiple recordings simultaneously, such as fast play and stop at the same time.
Click to stop operation synchronization.
When multiple recordings are played back at the same time, clicking this icon to the time sync mode, and all windows play recordings at the same time point as that of the currently selected window.
to stop time synchronization. Click
Click , and the system enables operation synchronization at the same time. The only way to cancel operation synchronization is to click .
Click this icon to play back recordings slowly.
Slow playback can reduce the speed to 1/2, 1/4, 1/8, and 1/16 of the normal speed.
Click this icon once to reduce the playback speed by one level.
Click this icon if you want to switch to frame-by-frame reverse playback.
This function enables only when playback pauses.
Click this icon to reverse playback, at this time the icon turns to . Click
to stop reverse play.
Click this icon and the recording starts playback, and the icon turns to .
Click to stop.
Click this icon if you want to switch to frame-by-frame playback.
This function enables only when playback pauses.
Click this icon to play back recordings quickly.
Fast playback can accelerate the speed of play to 1, 2, 4, 8, 16 times the normal speed.Click this icon once to increase the playback speed by one level.
62
Icon
Time bar
User’s Manual
Description
Shows the playback speed. Drag left or right and the recording is played in the fast reverse or fast forward mode.
Click this icon to take snapshots.
Click this icon to clip the recording, and save the clipped recording to a
specified location. For details, see 8.4.2Clipping Recording.
Control the volume.
Drag
Click
to adjust the volume.
to switch to the mute mode, and the icon turns to .
Click to unmute.
Click this icon to display the window in full screen.
Display the type of recording and the period of recording.
The time bar shows two recording bars. The upper one displays the recording time of the selected window, and the lower one displays the recording time of all selected cameras.
On the time bar, recording types vary from colors. A blank time bar means there are no recordings.
Time cursor displays the date and time of recording playback. The time cursor automatically adjusts according to the playback progress.
The following operations can be done on the time bar:
Click the time bar, rotate the mouse wheel, and adjust the
time accuracy of the time bar.
Press and hold the time bar, drag it left or right to check the hidden recording time.
Drag the time cursor to adjust the start time of the recording playback.
Click or drag the time cursor to a position on the time bar where there is a recording. The system starts playing back the recording from the located time point.
Click or drag the time cursor to a position where no recordings exist to stop recording playback.
63
Icon
User’s Manual
Description
Right-click menu. Right-click the playback window and the system displays the right-click menu.
Digital: Partially zoom in the recording image and view the details of this part.
Original: Set the image scale of the playing window.
Enable: The system automatically adjusts the image scale of the playing window based on the video resolution.
Disable: The system automatically adjusts the size of the playing window based on the number of selected cameras and the blank of the play region.
Audio: Set audio output.
Point to the playback window and the system displays the task bar. Click this icon to close the recording playback window.
8.4.2
Clipping Recording
Clip the recording, and save the clipped recording to a specified location.
When you operate on local interface, connect the USB storage device to the Device.
Select PLAYBACK .
Play back the recording. For details, see 8.4.1Playback.
Click .
The time bar displays recording clip frame, see Figure 8-27.
Recording clip frame
Hold the recording clip frame (such as the blue frame in ), drag it left or right to select the start time and end time for clipping.
Click Save immediately.
Click Browse to choose where to save the clipped recording.
Click OK .
Save the clipped recording to where you choose.
8.4.3
Image Playback
You can view manual snapshot and video detection snapshot.
Select PLAYBACK .
Select the camera, and then click the Image .
Only one camera can be selected.
64
Image playback ( 1 )
User’s Manual
Select the type of image, including manual snapshot and video detection snapshot.
Query time is set by the following methods:
Method A: Click the date or time in the time frame to modify date or time value.
Method B: Click the date or time in the time frame, rotate the mouse wheel to adjust date or time values.
Method C: Click , set date and time on the displayed calendar, and then click OK ,
On the calendar interface, if a date is underlined by dots (such as date has images.
Calendar interface
), meaning this
Click Search .
65
User’s Manual
The list at the left side displays the selected cameras. Click a camera and the corresponding thumbnail of recordings is displayed at the right side.
Click or to display the hidden thumbnails.
Point to the thumbnail to view information of the corresponding recording including the name of the camera storing this file, start time and end time of the recording.
Point to the list of thumbnail and the interface displays hide the thumbnail list. After hiding the list of thumbnails, click
. Click this icon to
to display the thumbnail list.
Drag the thumbnail to the play window, or double-click the thumbnail.
The system starts image playback as shown in
图 8-30. For details, see Table 8-11.
Image Playback
Icon
/
Point to the playing window, and the following icons are displayed.
Table 8-11 Description of Image playback icons
Description
Click this icon to switch to the previous or next image.
/
Switch images.
When playing back images one by one, click this icon to switch to the previous or next image.
When playing back multiple images simultaneously, click this icon to switch to the previous or next group of images.
66
Icon
User’s Manual
Description
Click this icon to display the window in full screen. Click again to exit full screen.
8.4.4
Exporting Files
Export recordings or images to a specified location to prevent their loss.
By default, the system exports recordings in the format of DAV, and images in JPG.
When you operate on local interface, connect the USB storage device to the Device.
Select PLAYBACK .
Search recordings or images.
1) Select a camera.
2) Click the Record or Image on the bottom on the interface.
3) Set the search conditions.
4) Click Search .
5) The system displays the thumbnails of searched recordings or images.
Select the thumbnails of recordings or images you want to export.
1) Point to the thumbnail and click to select the thumbnail. means the thumbnail is selected.
2) Click Select Again and the thumbnails of all recordings or images are canceled.
Click . The system displays Save interface.
In this chapter we take exporting a recording as an example, and the actual interface shall prevail.
67
Click Save .
User’s Manual
Click Browse to choose where to save the clipped recording.
Click OK .
68
User’s Manual
9
Settings
Device Management
You can manage the Device or a connected camera.
9.1.1
Managing Device
You can view and modify the information of the Device and storage plans.
9.1.1.1
Device Attributes
You can view the information of the Device such as MAC address, video input and output, and modify Device name and descriptions.
Click on the homepage, and select Device .
Select the root node from the device list, and then click ATTRIBUTE .
Attribute
Modify the Name and Description , and click Save.
9.1.1.2
Storage Configuration
Set the global recording storage plan and image storage plan based on your needs.
By default, recording and image storage plans set on this interface applies to all added cameras.
You can select a remote device to set the corresponding storage plan. Fore details, see
9.1.2.4.5Storage Configuration.
69
Select DEVICE.
Select the root node from the device list, and then click STORAGE .
Storage
User’s Manual
Setting system parameters.
Parameter
Storage
Table 9-1 Description of storage parameters
Description
Select the recording plan.
Continuous recording: Camera records 24 hours.
No recording: Camera does not record.
Event recording: Camera records only when an event alarm is triggered.
Settings Set the length of a manual recording.
Recording
On the live view interface, if you click to start recording and
Manual record
Pre-record do not click the icon again to end recording, the system automatically ends the recording based on the Manual Record you set.
This parameter is set only when selecting Event Recording .
The range is from 10 s to 30 s.
Manual snapshot
Set the number of images and speed of taking snapshots.
Image
Event snapshot
Set the interval for taking snapshots when an alarm-triggering event takes place.
Select Self-defining to customize the interval for taking snapshots.
The longest interval is 3600s.
Click Save .
9.1.2
Managing Camera
70
User’s Manual
You can connect cameras to the Device, modifying the IP address and configurations of cameras, and exporting the information of cameras and more.
9.1.2.1
Initializing Camera
Set the initial login password and IP address of a camera by initializing it. Only an initialized camera can be connected to the Device.
Click on the live view interface.
Homepage
Select DEVICE.
Device Management
Click Add.
Click Start Search .
The system starts searching for cameras and displays the research results.
71
Cameras
User’s Manual
Select an uninitialized camera and click Initialize .
By clicking Initialization State and then select Uninitialized , you can quickly screen out uninitialized cameras.
Device initialization
72
User’s Manual
Set the password and password protection method for the camera.
By enabling Using current device password and password protection , the camera automatically uses Device’s admin account information (login password and email). There
is no need to set password and email. You can go to Step 7.
1) Click protection.
if you want to cancel Using current device password and password
Setting password
2) Setting system parameters.
Parameter
Username
Table 9-2 Descriptions of password setting parameters
Description
The default username is admin.
Password
Set and confirm the password.
The password should consist of 8 to 32 non-blank characters and contain at
Confirm least two types of characters among upper case, lower case, number, and password special characters ( excluding“'” 、 “"” 、 “;” 、 “:” 、 “&” ) . Please set a high-security password according to the password strength prompt.
3) Click Next.
73
Password protection
User’s Manual
4) Set email.
If you forget the password of the remote device, you can retrieve the password through the email.
Click Next.
Modifying IP
74
User’s Manual
Set camera IP address.
If there is aDHCP server in the network, after selecting DHCP , the camera will automatically obtain a dynamic IP address without entering the IP address, subnet
mask, and default gateway.
If you select Static , you need to input IP address, subnet mask, default gateway.
When modifying multiple cameras at the same time, you need to set the
Incremental Value.
The fourth digit of the IP Address is increased in turn according to the incremental value you set.
If there is IP conflict when modifying static IP address, device pops up IP conflict prompt. If IP addresses are modified in bulk, device automatically skips the conflicted IP and begins the IP allocation according to the incremental value.
Click Next.
The system starts initializing camera and displays the initialization results.
Click Confirm and add or click OK .
Click Confirm and add to complete the initialization and add the camera. The system then returns to the Add Device interface.
Click OK to complete the initialization. The system then returns to the Add Device interface.
9.1.2.2
Adding Camera
The system supports Smart Add , Manual Add , and Import CVS File .
Table 9-3 Methods of adding devices
Adding methods
Description
Smart add
Manual add
Import CVS file
Search for cameras in the same network to filter and add. For details,
When you are not sure about the IP address of the camera, use Smart Add.
Manually enter the IP address, username, and password of a camera to add the
Device. See9.1.2.2.2Manual add.
When adding a few cameras and their IP address, username, and password are known, use Manual Add.
Fill information of the camera into a template and add the device by importing the
template. For details, see9.1.2.2.3Import CVS file.
When adding cameras in bulk and their IP addresses, usernames, and passwords are different, use Import CVS File.
9.1.2.2.1
Smart Add
Select DEVICE. The system displays device management interface.
Click Add. The system displays Smart Add interface.
75
Smart Add
User’s Manual
Click Start Search .
The system starts searching for cameras in the same network segment and displays the research results.
Search results
Click and the system displays the live view of the camera.
76
User’s Manual
The live view image of a camera can be reviewed only when the camera’s user (admin) password is admin or the same as the user (admin) password of the Device.
Live view
Adding a camera
Add a single-channel camera.
Select a camera, and then click Add . The system starts adding the selected device and displays the Add confirm
When adding a camera click Cancel and the camera is not added; click Stop to stop add this camera.
Double-click the address, username, password, manufacturer, and port of the camera to modify the corresponding information.
When you failed to add a camera, modify the information of the device according to onscreen instructions. Click Try again and you can add the camera again.
77
Add confirm(1)
User’s Manual
Add a multi-channel camera.
1.
After selecting a camera, click Add . The system displays Add confirm interface.
2.
Double-click Please select a channel . The system displays Video device interface.
Video device
3.
Select the channel you want to add.
Click and enter keywords into the search bar to quickly locate the channel you want to add.
4.
Click OK to add the selected channel.
Click Continue to add or Finish .
Click Continue to add and then the system adds the current camera. The Add
Device interface is displayed, where you can add another camera.
78
User’s Manual
Click Finish to complete adding. The Device interface is displayed, where you can view the information of added camera.
9.1.2.2.2
Manual add
Select DEVICE.
Select Add > Manual Add .
Manual add (1)
Click Manual Add .
79
Manual add (2)
User’s Manual
Parameter
Device type
Port
Setting system parameters.
Manufacturer
Address
Username
Password
Table 9-4 Parameter descriptions
Description
Select the type of the camera. The default type is Devices .
Select the communication protocol of the camera. The default is Private .
Double-click Private and you can select another protocol.
When adding a stream media device, select Rtsp as the communication protocol, and enter the RTSP address of the device into the Address item.
Enter the IP address or RTSP address of the camera.
For instance, the RTSP format of the Onvif device is rtsp://<Username>:<Password>@<IPAddress>:<Port>/cam/realmonitor?channel
=1&subtype=0.
For instance: rtsp://admin:[email protected]:554/cam/realmonitor? channel
=1&subtype=0
Port: 554 by default
Channel: The channel number of the stream media device you need to add.
Subtype: Stream type: 0 means main stream; 1 means sub stream.
Enter the username and password of the camera.
When adding a stream media device, no need to set the Username , Password , and Port .
Enter the port number of the camera.
80
Parameter
Operation
User’s Manual
Description
Delete or Add new rows.
Click to delete the camera information. After selecting multiple lines of remote device information, click Delete to delete the camera information in bulk.
Click to add a new row. After entering the camera information, you can add multiple cameras at the same time.
Adding a camera
Add a single-channel camera.
After selecting a camera, click Add to add a camera.
When adding a camera click Cancel and the camera is not added; click Stop to stop add this camera.
Double-click the address, username, password, manufacturer, and port of the camera to modify the corresponding information.
When you failed to add a camera, modify the information of the device according to onscreen instructions. Click Try again and you can add the camera again.
Add confirm(1)
Add a multi-channel camera
1.
After selecting a camera, click Add .
81
Add confirm(2)
User’s Manual
2.
Double-click Please select a channel .
3.
Select the channel you want to add.
Click and enter keywords into the search bar to quickly locate the channel you want to add.
4.
Click OK to add the selected channel.
Click Continue to add or Finish .
Click Continue to add and then the system adds the current camera. The Add
Device interface is displayed, where you can add another camera.
Click Finish to complete adding. The Device interface is displayed, where you can view the information of added camera.
9.1.2.2.3
Import CVS file
Select DEVICE.
Select Add > Import CSV File .
82
Import CSV file
User’s Manual
Fill in the template.
1) Click Download Template to download template.
Saving path might vary according to interfaces you operate on, and the actual interface shall prevail.
On local interface, you can select where to save files.
In local operations, connect the USB storage device to the Device.
On web interface, files are stored in the default path set up in the browser.
2) Fill in the template according to the real fact and click Save .
The system displays the information of camera you need to fill in. See Figure 9-20.
If the camera information is not complete, import the template, and then complete the information.
Template
Import the template.
1) Click Browse and select the template.
2) Click Import.
The system displays the information of the imported information of the camera.
When the camera information is incomplete, complete the information.
83
User’s Manual
Click if you want to delete this camera.
Adding a camera
Add a single-channel camera.
After selecting a camera, click Add .
When adding a camera click Cancel and the camera is not added; click Stop to stop add this camera.
Double-click the address, username, password, manufacturer, and port of the camera to modify the corresponding information.
When you failed to add a camera, modify the information of the device according to onscreen instructions. Click Try again and you can add the camera again.
Add confirm(1)
Add a multi-channel camera
1.
After selecting a camera, click Add .
84
Add confirm(2)
User’s Manual
2.
Double-click Please select a channel .
3.
Select the channel you want to add.
Click and enter keywords into the search bar to quickly locate the channel you want to add.
4.
Click OK to add the selected channel.
Click Continue to add or Finish .
Click Continue to add and then the system adds the current camera. The Add
Device interface is displayed, where you can add another camera.
Click Finish to complete adding. The Device interface is displayed, where you can view the information of added camera.
9.1.2.3
Modifying IP Address of Camera
You can modify the IP addresses of cameras that are not added.
You can only modify the IP address of an already initialized camera. For details, seeInitializing
You can only modify the IP address of a camera connected by a private protocol.
For how to modify the IP address of an added camera. See9.1.2.4.2Setting Connections.
Click on the homepage, and select Device .
Click Add and select the Smart Add .
Click Start Search .
You can click to filter the search according to the settings of manufacture, IP address.
85
Cameras
User’s Manual
Select the camera, and click Modify IP .
Modifying IP addresses of multiple devices in bulk is allowed. But in doing so, make sure that the username and password of all cameras are the same.
86
Modifying IP address of camera (1)
User’s Manual
Set camera IP address.
If you select DHCP , there is no need to input IP address, subnet mask, and default gateway. Device automatically allocates the IP address to the camera.
If you select Static , you need to input IP address, subnet mask, default gateway and incremental value.
When modifying multiple cameras at the same time, you need to set the incremental value. The fourth digit of the IP Address is increased in turn according to the incremental value you set.
If there is IP conflict when modifying static IP address, device pops up IP conflict prompt. If IP addresses are modified in bulk, device automatically skips the conflicted IP and begins the IP allocation according to the incremental value.
Enter the username and password of the camera.
Click Next.
Click OK.
9.1.2.4
Configuring Camera
You can set the information such as attribute, connection, and video parameters of added cameras.
The functions and interfaces might vary according to different cameras you add, and the actual interface shall prevail.
87
9.1.2.4.1
Attribute Settings
You can set the camera name and view device information.
Select DEVICE.
Select a camera/ media stream/ POE, and click the ATTRIBUTE .
Attribute
User’s Manual
Setting attribute parameters.
Table 9-5 Descriptions of attribute parameter
Parameter Description
Name
Set the name of the camera.
Enable Sync to camera , and then save settings, the modified name will be synchronized to the camera.
Description Enter descriptions of this camera.
Device information
Displays information of the camera including its model, serial number, MAC address, storage capacities of audio and video files, amount of alarm inputs and outputs, and system version.
Click Save .
9.1.2.4.2
Setting Connections
You can modify the connection parameters of the camera such as IP address and port number.
Select DEVICE.
Select a camera and click CONNECTION .
88
Connection
User’s Manual
Change the IP address .
1) Click the icon corresponding to the Address .
Modifying IP
2) Enter IP address, subnet mask, and gateway.
3) Click OK to save the modifications.
Modify the port number.
The port number corresponds to the connection protocol of the device. The protocols vary from different port numbers.
1) Click the icon corresponding to the Port .
89
User’s Manual
Modify the port.
2) Modify the port number.
3) Click OK .
Set the connection parameters.
Parameter
Table 9-6 Descriptions of connection parameter
Description
Manufacturer Select the communication protocol of the camera.
Username Enter the username and password of the camera.
Password
Link type
The password should consist of 8 to 32 non-blank characters and contain at least two types of characters among upper case, lower case, number, and special characters ( excluding“'” 、 “"” 、 “;” 、 “:” 、 “&” )。 Please set a high-security password according to the password strength prompt.
Displays the link type between the Device and camera. The default setting is
Self-adaptive .
Set the caching strategy of video streams of camera.
Self-adaptive: The system auto adjusts the video stream cache based on the bandwidth.
Cache strategy Real-time: Guarantees that videos are real-time, but small bandwidth can result in lagged videos.
Smooth: Ensures that videos are smooth, but sometimes at the cost of low definition.
Click Save .
9.1.2.4.3
Setting Video Parameters
Set video parameters of different stream types based on the actual bandwidth. The functions and interfaces might vary from different front-end equipment, and the actual interface shall prevail.
Select DEVICE.
After selecting a camera, click VIDEO .
90
Video
User’s Manual
Click Main Stream , Sub Stream 1 or Sub Stream 2.
Different devices work with different stream modes and the actual interface shall prevail.
Configure normal video quality parameters.
Table 9-7 Descriptions of video parameters
Parameter Description
Enabling smart code helps improve image compression performance and reduce storage space.
Smart code
Enable smart code and the Device will not support the third stream, ROI, and other functions. The actual interface shall prevail
Encode mode
Used to set the video encode mode.
MJPEG: Motion JPEG encoding.
H.264
: Main Profile encoding
H.264H
: High Profile encoding
H.264B
: Baseline Profile encoding
Set video resolution. The higher the resolution, the better the image quality.
Resolution
FPS
Stream mode
Different devices support different resolutions and the actual interface shall prevail.
Set frames per second. The higher the FPS, the more real and more smooth the image is.
Set thevideo stream mode.
CBR (Constant Bit Rate): The bit rate changes little and keeps close to the defined bit rate value.
VBR (Variable Bit Rate): The bit rate changes along with environment.
Set the video image quality, including low, meddle, and high.
Quality
When the Stream Mode is set to VBR , this parameter can be set.
91
User’s Manual
Parameter Description
Set the video stream value.
Stream
Main stream: Setting of the stream value changes the image quality; the higher the value, the better the image quality.
Sub Stream: In the CBR stream mode, the bit rate changes little and keeps close to the defined bit rate value; in the VBR stream mode, The bit rate changes along with environment and the maximum value keeps close to the defined bit rate value.
I frame interval
Used to define the amount of P frames between two I frames. It is recommended to set the I frame interval two times as the FPS.
Set Event Video Quality , and set FPS and Stream Mode.
Only the main stream mode allows for setting Event Video Quality .
Click Save .
9.1.2.4.4
Setting OSD
Overlay information such as time and channel on video image of camera.
Select DEVICE.
Select a camera and click OSD .
OSD
Set the stack information based on actual needs.
Device Name
Click to overlay the name onto the video.
Click if you want to modify the device name and where it is displayed.
92
User’s Manual
Time Stack
Click to overlay the time onto the video.
Click if you want to modify the device name and where it is displayed.
Geographical Position
1.
When setting the position, click or to create a textbox, and then enter the position information of the camera.
Geographical position
Click to adjust the alignment of texts.
Click or again to create a textbox over or under the previously created textbox.
Click to delete the textbox.
2.
Drag the textbox to a proper position.
3.
Click
Click Save .
.
9.1.2.4.5
Storage Configuration
Set the recording storage plan and image storage plan of cameras as needed.
Select DEVICE.
Select a camera and click STORAGE .
93
Storage
User’s Manual
Select Inherit local storage plan or Customize .
Inherit local storage plan: The camera inherits the global storage plan of the Device.
Customize: Customizes the storage plan of camera.
Setting storage parameters.
When selecting Inherit local storage plan , only Record Stream needs to be set up.
Parameter
Recording
Recording plan.
Table 9-8 Description of storage parameters
Description
Select the recording plan.
Continuous recording: Camera records 24 hours.
No recording: Camera does not record.
Event recording: Camera records only when an event alarm is triggered.
Settings Set the length of a manual recording.
Manual record
On the live view interface, if you click to start recording and do
Record stream not click the icon again to end recording, the system automatically ends the recording based on the Manual Record you set.
Select Record Stream mode, including main stream, sub stream1 and sub stream2.
Image
Manual snapshot
Set the number of images and speed of taking snapshots.
94
Parameter
Event snapshot
Click Save .
User’s Manual
Description
Set the interval for taking snapshots when an alarm-triggering event takes place.
Select Self-defining to customize the interval for taking snapshots.
The longest interval is 3600s.
9.1.2.5
Exporting Camera Information
You can export the information of added cameras. In the case of information loss caused by restoration of factory settings or system errors, import camera information to quickly restore camera.
Select DEVICE.
Click at the lower-left corner.
Click Download Template to download template of the camera, and then you can add cameras by using the template.
Export
Select Whether The Encryption .
If selecting Yes , the system exports encryptedbackup files which can only be viewed
in the Device.
If selecting No , the system exportscsv files which can be opened by using Excel and other tools. An exportedcsv file includes the IP address, port number, channel number, channel name, manufacturer, and username (without password) of the camera.
When exporting non-encrypted files, properly save them to avoid data leakage.
Click OK .
Click Save File .
Saving path might vary according to interfaces you operate on, and the actual interface shall prevail.
On local interface, you can select where to save files.
In local operations, connect the USB storage device to the Device.
On web interface, files are stored in the default path set up in the browser.
95
9.1.2.6
Viewing Device Connection Status
Go to the Device interface, and view the connection status of cameras in the device list.
User’s Manual
Such status means the device is online, and means the device is offline.
Right-click an offline device and select Connect if you want to connect to this device again.
Right-click an online device and select Disconnect if you want to disconnect with this device.
9.1.2.7
Deleting Camera
Go to the Device interface, where you can delete an added camera or delete them in bulk.
Single delete
Select a camera and click .
In the device list, right-click a camera, select Delete .
Delete in bulk
Click , and then the check box is displayed in the device list. Select multiple cameras and click .
In the device list, select a camera, hold Ctrl or Shift. Then you can select cameras you want to delete, and then click .
Network Management
Set the network parameters of the Device and make sure that this Device is interconnected with other devices.
9.2.1
Modifying IP Address
Modify the IP address and DNS server of the Device based on network planning.
Click on the homepage, select NETWORK > TCP/IPv4
To select the items to be displayed, you can click .
.
96
TCP/IPv4
User’s Manual
Click the icon corresponding to the network port.
Editing ethernet network
Parameter
Parameter
Speed
Use dynamic IP address
Use static IP address
Table 9-9 Descriptions of NIC editing
Description
Maximum network transmission speed of current NIC.
When there is aDHserver on the network, select the check box to use dynamic IP address. System can distribute a dynamic IP address to the Device. There is no need to set IP address manually.
Set static IP address, subnet mask and gateway. It is to set a static IP address for the Device.
97
User’s Manual
Parameter Description
Set NIC MTU value. The default setup is 1500 Byte.
We recommend that you check the MTU value of the gateway first and then set the device MTU value equal to or smaller than the gateway value. It is to reduce the packets slightly and enhance network transmission efficiency. MTU
Changing MTU value might result in NIC reboot, network offline and affect current running operation. Be careful.
Click OK .
Set DNS Server parameters.
You can select to obtain the DNS server address automatically or manually enter.
When activating the domain name service, this step must not be skipped.
Obtain DNS server address automatically: Select Obtain DNS server address automatically , and then the system automatically gets the IP address of the DNS server.
Use the following DNS server address: Select Use the following DNS server address , and then you need to enter the IP address of the preferred DNS and the alternate
DNS.
Set the default NIC.
Select Default Ethernet from the Default NIC drop-down list as needed.
Only NIC which has been connected to the network can be used as the Default NIC.
Click Save .
9.2.2
Setting Port Number
You can set device port number.
Select NETWORK > PORT .
Port
98
User’s Manual
Set the parameters.
Table 9-10 Descriptions of port parameters
Parameter Description
Max connection Select the number of connections from 1 to 128 as needed.
TCP port
RTSP port
HTTP port
Select the number of connections from 1025 to 65535 as needed. The default value is 37777.
Select the number of connections from 1 to 65535 as needed. The default value is 554.
Select the number of connections from 1 to 65535 as needed. The default value is 80.
If the value you set is not 80, add the port number after the IP address when you use browser to log in to the Device.
HTTPS port
UDP port
Select the number of connections from 1 to 65535 as needed. The default value is 443.
Select the number of connections from 1025 to 65535 as needed. The default value is 37778.
Click Save .
9.2.3
Configuring Email
Configure email information, and enable email alarm linkage. When the Device has alarm events, the system automatically sends email to the user.
Select NETWORK > EMAIL .
Click to enable the email function.
Setting email parameters.
Table 9-11 Descriptions of email parameter
99
User’s Manual
Parameter Description
Email server Select email server type, including Customize, 126Email, 163Email, and QQEmail.
Server address
Encryption
Enter the email server address..
Select the encryption type of the email server from NONE, SSL, and TLS.
Port
Username and password
Enter the port number of the email server.
Enter the username and password of the email server.
Table 9-12 Description of common email configuration parameters
Type
Email server Encryption Port Description
QQ smtp.qq.com SSL 465
The encryption method cannot select
NONE .
Email must subscribe SMTP service.
The password must use the
Authorization Code , and the QQ password and email password are invalid.
SSL
TLS
465/
994
25
Authorization code is obtained when the
SMTP service is enabled in the mailbox.
Email must subscribe SMTP service.
The password must use the
Authorization Password, and the email password is invalid. 163 smtp.163.com
NONE 25
Authorization password is obtained when the SMTP service is enabled in the mailbox.
126 smtp.126.com NONE 25
Add the information of email receiver
1) Click Add.
2) Enter the email address of the receiver.
Email must subscribe SMTP service.
Email address
Click Add or to add other receivers’ email addresses.
Click to delete an added receiver.
Select a receiver. The Delete button is displayed. Click Delete to delete the selected receiver.
100
User’s Manual
Click Save .
(Optional) Test whether the emails can be sent and received as intended.
1) In Test Mail , select or enter a receiver’s email address.
2) Click Send .
When the configuration is correct, the system pops up a message of success, and the receiver will receive the test mail.
Otherwise, the system pops up a message of failure, and the receiver will not receive the test mail.
9.2.4
Setting SWITCH
Set the SWITCH. When IPC is directly connected to the PoE port of the Device, the system auto distributes an IP address to the IPC based on the preset IP segment. The Device auto connects to this IPC.
Do not connect a SWITCH to the PoE; otherwise the connection might fail.
The Device enables SWITCH by default, and the IP segment is 10.1.1.1. Maintaining the default setting is recommended.
Procedures
Select NETWORK > PORT .
SWITCH
Set IP parameters.
The IP address of the SWITCH cannot be in the same segment as the IP address of the
Device. Using the default IP is recommended.
Click Save .
101
9.2.5
Configuring Auto Register
Procedures
Select NETWORK > PORT .
Auto Register
User’s Manual
Click to to enable auto register.
Set relevant parameters of auto register.
Click Save .
9.2.6
Configuring UPnP
Procedures
Select NETWORK > PORT .
UPnP
Click to to enable port mapping.
Set the Intranet IP and Internet IP.
Set the port mapping table.
102
User’s Manual
Click in the function bar, and then select function types displayed in the port mapping table, including service name, protocol, internal port, external port, and operation, and more.
Port mapping table(1)
Click corresponding to the mapping port to modify port mapping (only the external port number can be modified), and then click OK .
Port mapping table(2)
Port mapping modification
Click Save .
Storage Management
Storage management includes managing the stored resources (such as recordings) and storage space, so you can use and improve utilization ratio of storage space.
9.3.1
HDD
The physical HDD refers to the HDD installed on the Device. On this interface you can view information such as the capacity (free space, total space) of the disk, and disk information.
Click on the homepage, and select STORAGE > HDD .
There is a corresponding icon near the HDD name after you create the RAID and hotspare
HDD.
: RAID HDD.
: Global hotspare HDD.
: Invalid private hotspare HDD.
103
HDD
User’s Manual
9.3.1.2
View S.M.A.R.T Information
S.M.A.R.T is so called Self-Monitoring Analysis and Reporting Technology It is a standard used to detect HDD drive status and report potential issues. The system monitors and records the running status of HDDs and compare parameters with preset safety range. When the monitored parameters fall out of the safety range, the system prompts alarms to guarantee the safety of HDD data.
You can view the S.M.A.R.T information of only one HDD at one time.S.M.A.R..
Enter the HDD interface, choose HDD, and click
If any anomaly is found, timely repair the HDD.
. Check whether the HDD is normal.
104
ViewS.M.A.R.T Information
User’s Manual
9.3.1.3
Set Storage Strategy
You can set the recording strategy when the HDD space is full.
Select STORAGE > HDD .
Click Storage Strategy .
Set storage strategy
Set Storage Strategy .
Overwrite: If the free space of HDD is below 50 GB or is less than 1% of the total space
(the system select the larger), the system continues recording and overwrites the recording file stored the earliest.
Stop: If the free space of HDD is below 50 GB or is less than 1% of the total space (the system select the larger), the system stops recording.
Click OK .
105
User’s Manual
9.3.1.4
HDD Defragmentation
After the HDD works for a period time, since it is repeatedly written or files are deleted, the files are saved on the discontinued physical position on the HDD. It might result in too much HDD fragmentation and slow down the HDD access speed. The HDD optimization is to organize the fragmentation files on the HDD and make the fragmentation files become the continuous files. It can enhance HDD whole performance and running speed.
HDD optimization can result in the loss of some recordings. Be careful.
Select STORAGE > HDD .
Select one or several HDD(s) and click .
Set the HDD defragmentation strategy.
Select the HDD defragmentation strategy..
Speed first: HDD optimization at a high speed up to 100 M/s.
Business first: The system auto adjusts the HDD optimization speed based on the business load on the Device.
Click OK .
Click OK .
The system starts HDD optimization, and the disk State shows HDD Optimizing . After optimization, the State goes back to Running .
9.3.1.5
Formatting
Formatting clears all files from the disk. Be careful.
Go to the HDD interface, select one or several HDD(s), and click Format to format the selected
HDD.
Event
Set the alarm manner for system errors. The alarm is triggered if errors happen during the operation of the Device.
106
Different devices support different event types, and the actual interface shall prevail.
Click on the homepage, and select EVENT .
Event
User’s Manual
means the abnormal event alarm is enabled.
This chapter takes setting No-HDD as an example.
Select the specific device (or root directory) from the device list.
Select the specific event alarm. For example, No-HDD .
No-HDD
Click to to enable the No-HDD alarm.
Set alarm linkage events.
Click and select Buzzer, LOG, Device Alarm Output or Email to enable
corresponding alarm linkage, as shown in Figure 9-51. See Table 9-13 for descriptions of
alarm linkage.
107
User’s Manual
For example, if you select IPC Alarm Output , you can set the output port and delay time.
Alarm linkage events
Table 9-13 Descriptions of alarm linkage events
Alarm linkage events
Description
Recording
Snapshot
Buzzer
When an alarm is triggered, the system links with the selected camera to take recording.
When an alarm is triggered, the system links with the camera to take snapshots.
When an alarm is triggered, the system gives the buzzer.
Log
When an alarm is triggered, the system records alarm information in the log.
When an alarm is triggered, the system sends alarm emails to all added receivers.
When an alarm is triggered, the system links
Local alarm output with the alarm output device to trigger the alarm.
IPC alarm output
When an alarm is triggered, the system links
Click Save . with the alarm output device to trigger the alarm.
Preconditions
Surveillance devices, such as IPC, are added.
—
—
—
Emails configuration completed.
The Device is connected with an alarm output device.
IPC is added and connected to the alarm output device.
108
User’s Manual
System
You can make configurations of the system such as general parameters, schedule, time and more.
9.5.1
Setting System Parameters
You can make configurations such as setting the system language, user logout time, and mouse moving speed.
Click on the homepage, and select SYSTEM > SYSTEM.
System
Set the parameters.
Parameter
Language
Table 9-14 Descriptions of system parameters
Description
Set the system language.
Select the video standard.
PAL is mainly used in China, Middle East, and Europe.
NTSC is mainly used in Japan, USA, Canada, and Mexico.
Video standard
User logout time
Live view control
Video standard is a technical standard used to process video and audio signals. PAL and NTSC vary in encoding and decoding methods, and field scanning frequency.
Set the user logout time. When you remains inactive for a specified period or the device exceeds the set value. After auto logout, the user needs to login again to operate.
If the User Log-out Time is set to Non cancellation, the system does not automatically log out.
After selecting this function, you can enter local live view without entering the username and password.
Mouse moving speed
Click Save .
Set the mouse moving speed ion the local interface.
109
User’s Manual
9.5.2
Setting time
Set the system time for the Device and select whether to enable NTP as necessary. After enabling
NTP, the Device automatically synchronizes time with the NTP server.
Select SYSTEM > TIME .
Time
Parameter
Parameter
Time
Table 9-15 Descriptions of system parameters
Description
Time and date Set the date and time of the system. You can manually set the system time, or set the Device to automatically synchronizes time with the NTP server.
Manual setting: Select Manual Setting and set the correct date and time.
Sync with the Internet time server: Select Sync with Internet Time
Server , enter the IP address or domain of the NTP server, and then set and then set Auto Sync Time Interval.
Time and date format
Time zone
Settings Time and date format.
Auto time synchronization
Select the Device time zone.
After enabling this function, the Device checks the system time of the camera after every preset time interval. If the local Device time and the camera time are not the same, the time of the camera is automatically corrected.
(Optional) Setting DST.
DST is a system to manually regulate local time, which is designed to save energy consumption. If the country or region where this Device is located adopts the DST, you can enable DST to ensure that system time is correct.
1) Click to to enable DST.
110
2) Select the DST type, including Week and Date.
3) Set the start time and end time of the DST.
Click Save .
9.5.3
Display Output
Enable the monitor, monitor resolution, refresh rate of the connected device.
Select SYSTEM > Display Output .
Display output
User’s Manual
Select the output port and the main and profile views.
It displays that output here corresponds to the video output interface on the rear panel of the device, display output 1 corresponds to DVI1, and display output 2 corresponds to
DVI2.
Set output mode and resolution.
Parameter
Output mode
Resolution
Image Setting
Table 9-16 Display output descriptions
Description
Security screening mode and Monitor mode are selectable.
Security screening mode : Display the process of baggage security screening and the AI analysis result of suspect items.
Monitor mode : Display the live view.
The default value is 1920× 1080@60FPS.
Set the image enhancement effect for the current output screen.
In automatic mode, the screen is displayed according to the enhancement effect of the actual operation.
Select image enhancement effects, including 13 image enhancement modes such as black and white and partial enhancement. If you select the black and white mode, the screen will display the black and white effect by default. In live view status, the image enhancement operation on will not take effect.
Set display area
111
User’s Manual
Mode
Security
Screening
Mode
When connected to the single-view devices, security screening mode and monitoring mode by default; when connected to the dual-view devices, both security screening mode by default.
Parameter
Table 9-17 Display area descriptions
Scanned Baggage
Description
After enabling the function, the live view interface displays scanned baggage images. Up to 100 baggage can be
Record
Add Tunnels
Operation Bar displayed.
Click Setting to set the danger level of the display item.
Add a video channel to the baggage security screening video to view real-time video at the same time.
Click , select the video channel, click OK .
After selecting the function, the live view interface displays operation bar. Click the corresponding Setting , and set the operation bar.
Drag the frequently used functions from the function list to the frequently used function area for daily use.
In the custom function area, click at the lower right corner and select the image enhancement effect. Click
OK . The settings correspond to the functions of F1, F2, and F3 keys on the keyboard.
Status Bar
After enabling the function, the live view interface displays the status bar.
Window Split Method
Monitoring
Mode
Add Tunnels
Select method.
to set the window split
Click in the window to select the corresponding video channel displayed on the live view interface.
Operation bar settings(1)
112
Operation bar settings(2)
User’s Manual
Click Save .
9.5.4
Setting Schedule
Create a schedule of valid range of time. This schedule can be directly used when you configure arm/disarm period of alarm and recording. The system only implements these settings during the valid period of the calendar.
Select SYSTEM > SCHEDULE > SCHEDULE .
Schedule
Add schedule
1) Click .
113
Add Schedule
User’s Manual
2) Set Schedule Name.
3) Click OK to save the settings.
Select the added schedule and click to delete the selected schedule.
Select the way of setting a valid range of time, from two options Always Effective and
Customize .
Set valid period of schedule.
Click the blue area and is displayed. Drag to adjust the start time and end time of the valid period.
Hold any of the vacant point on the time bar and drag rightward to add a new valid period.
Click Clear to clear all the valid periods in the current schedule.
Select a certain valid period and click Delete to delete the selected period.
This step is required only when Custom is selected.
Each schedule supports up to 50 effective time ranges.
Click Save .
The blue area on the time axis shows the effective time.
Account Management
User management of the Device includes the management of individual user and user group, whose basic information can be managed. To conveniently manage the user, we recommend the general user authorities shall be lower than high-level user authorities.
To guarantee the safety of the Device, operations (such as adding or deleting a user) on the
Account interface require entering the correct login password.
After a correct login password is entered on Account interface, if you do not close Account interface, you can do other operations directly. If you close the interface and enter it again, you shall enter the correct login password again. The actual interface shall prevail.
114
User’s Manual
9.6.1
User Group
Different users might have different authorities to access the Device. You can divide the users to different groups. It is easy for you to maintain and manage the user information.
The systemallows for creating up to 64 user groups. User group name supports maximum 64
characters.
In default settings, the system has these user accounts: maintainer, operator, and admin; the admin user group cannot be deleted.
New user group can only be created under the root.
9.6.1.1
Adding User Group
Create user groups to facilitate user management as needed.
Click on the homepage, and select Account .
Select a root from the list on the left and click
Input password
.
Enter the password of the admin user and click OK . The system creates a user group.
Attribute
Setting parameters.
115
User’s Manual
Parameter
Name
Group name
Table 9-18 User management parameters
Description
Set user group name.
A user group name can contain up to 64 characters consisting of letters, numbers, and special characters (including "_", "@",“”).
Shows the organization node of the user group. The system automatically recognizes the group name.
Set the email address of the user group. Email
Description
User list
Enter the descriptions of the user group.
Displays the user information under the user group.
Setting user group authority.
1) Click the AUTHORITY .
Authority
2) Set user group authority based on your actual needs.
indicates the corresponding authority is enabled.
Click the check box at the top of the authority list (such as and all authorities in this list are selected.
Click Save .
9.6.1.2
Deleting User Group
A user group can be deleted only when it has no users.
The admin user group can never be deleted.
On the Account interface, select a user group and click to delete the selected user group.
)
116
9.6.2
User Access
9.6.2.1
Admin
All permissions are enabled by default.
9.6.2.2
Operator
Operator permission
User’s Manual
9.6.2.3
Maintainer
117
Maintainer permission
User’s Manual
9.6.3
User
The Device user can access and manage the Device. The admin account is the default administration user of the system.
9.6.3.1
Adding User
You can add multiple users as needed and make sure that a user only has access to resources within own authority.
User authorities adopt the user group authority settings. It is read-only.
Click on the homepage, and select Account .
Select the admin user group or a new user group, and click .
118
Attribute
User’s Manual
Setting parameters.
Parameter
Name
Group name
Table 9-19 User management parameters
Description
Set user name.
A user group name can contain up to 31 characters consisting of letters, numbers, and special characters (including "_", "@”,“”).
Shows the organization node of the user. The system automatically recognizes the group name.
Password Set and confirm the User password.
The password can consist of 8 to 32 non-blank characters and contain at least two types of characters (excluding“'” 、 、 、 “&” ) according to the feedback on password strength. Confirm password Hold the mouse over and the password becomes visible. Release the left mouse button or move the mouse pointer elsewhere, and the password become invisible again.
Set the email address of the user. Email
Description Enter the descriptions of the user.
(Optional) Click the AUTHORITY and set user authority.
By default, the user inherits all authorities of its user group.
119
Authority
User’s Manual
Click Save .
9.6.3.2
Modifying User
A user account with user management authority can modify its own information and information of other users.
Select Account .
Select the target user for password modification.
Modify user password.
Another way to modify password is to click interface and select Modify Password.
at the lower-left corner of the
1) Click .
Input password
2) Enter the password of the admin user and click OK .
120
Changing password.
User’s Manual
3) Set and confirm the password.
4) Click OK .
Setting other user parameters.
The username and user group of this user cannot be modified.
Click Save .
9.6.3.3
Deleting User
On the Account interface, select a user, and then click to delete the selected user.
9.6.3.4
Resetting Admin Password
A lost admin login password can be reset by using the reserved email or security questions.
Go to the login interface.
Login Interface
Click Forgot Password?.
121
Prompt interface
User’s Manual
Click OK .
If you have reserved an email, use the email to retrieve the password.
If no email is reserved, set one and click Next .
Reset the login password.
Retrieving password with email Follow onscreen instructions to scan the QR code, get the security code sent to the email you reserved, and then enter this security code.
Scanning the same QR code can get two security codes at most. To get another security code, refresh the QR code interface.
The security code is valid for 24 hours.
Click the Reset Type drop-down box, and select Security Questions . The Security
Questions interface is displayed. Select a security question and enter the preset corresponding answer correctly in the Answer text box.
Click Next.
Setting parameters.
Parameter
User
Password
Confirm password
Table 9-20 Descriptions of password parameters
Description
The default username is admin.
The password should consist of 8 to 32 non-blank characters and contain at least two types of characters among upper case, lower case, number, and special characters ( excluding“'” 、 “"” 、 “;” 、 “:” 、 “&” )。 Please set a high-security password according to the password strength prompt.
Prompt question
Click OK .
After setting the Prompt Question , move the mouse pointer over on the login interface. The system displays the prompt question you have set to help you recall the password.
122
User’s Manual
Log in with the new password.
9.6.4
ONVIF User
When a camera is connected with the Device by the ONVIF protocol, you need to use the verified
ONVIF account.
By default, the system has three ONVIF user groups (admin, user, and operator) and does not allow manually creating an ONVIF user group.
Directly adding users to the Onvif user group is not allowed.
9.6.4.1
Adding ONVIF User
Click on the homepage, and select Account .
Select user groups under Onvif .
Attribute of ONVIF user group
Click .
Input password
123
Enter the login password of the current user, and then click OK .
Attribute of ONVIF user
User’s Manual
Set the parameters.
Parameter
Name
Group name
Password
Confirm password
Description
Click Save .
Table 9-21 Descriptions of ONVIF user parameters
Description
Set user name of ONVIF.
ONVIF A user group name can contain up to 31 characters consisting of letters, numbers, and special characters (including "_", "@”,“”).
Shows the organization node of the user. The system automatically recognizes the group name.
Set the password of ONVIF user.
The password can consist of 8 to 32 non-blank characters and contain at least two types of characters (excluding“'” 、 “"” 、 “;” 、 “:” 、 “&” ) ). Set a strong password according to the feedback on password strength.
Enter the descriptions of the ONVIF user.
9.6.4.2
Deleting ONVIF User
The admin user can never be deleted.
Click on the homepage, and select Account .
Click the ONVIF user and then click .
124
Input password
User’s Manual
Enter the login password of the admin user and click OK .
Click OK .
Security Management
9.7.1
Setting IP Access Authority
Set the IP host allowed to access the Device to enhance security for the network and data.
Click on the homepage and then select SECURITY > IP ACESS AUTHORITY .
IP access authority
Select the method to control IP access authority.
Click Allow all access , and all IP hosts in the same LAN can access the current Device.
Click Reject access list and add an IP host list. The IP host in the list is not allowed to access the current Device.
Click Allow access list and add an IP host list. Only the IP host in the list is allowed to access the current Device.
Adding IP host.
125
User’s Manual
The following steps are needed only when you clicked Reject access list or Allow access list .
1) Click Add.
Adding IP host
2) Select Add Type and set the IP address or MAC address of the IP host.
If selecting Single IP , enter the IP address of the IP host.
If selecting IPV6 addr , enter the IP range and add multiple IP hosts within this range to the list.
If selecting MAC , enter the MAC address of the IP host.
3) Click OK to add the IP host.
Click Add to add more IP hosts.
Click to edit IP host.
Select an IP and click Delete to delete the IP host.
IP host list
Click Save .
126
User’s Manual
9.7.2
Setting Safety Protection
You can set the login password lock strategy once the login password error has exceeded the specified threshold. System can lock current IP host for a period of time.
Select SECURITY > SAFETY PROTECTION .
Safety protection(1)
Click to to enable safety protection.
Remote: When you log in to device on web interface, once the login password error has exceeded the threshold, system locks the IP host for a period of time.
Local: When you log in to device on local interface, once the login password error has exceeded the threshold, system locks the IP host for a period of time.
Set the most suitable lockup strategy based on actual needs.
Click Save to save the settings.
Once the IP host has been locked, you can view the locked IP host on the list. Select an IP host, click Unlock or the corresponding to unlock this IP host.
9.7.3
Setting System Service
Select SECURITY > SYSTEM SERVICE .
127
System service
User’s Manual
System service
SSH
Password reset
CGI service
ONVIF service
Private protocol authentication mode
Enable or disable the system service based on the actual needs.
Table 9-22 System service
Description
After enabling this function, you can access the Device through the SSH protocol to complete system adjustment and IP settings. SSH is disabled by default.
After this function is enabled, a lost admin login password can be reset by using the reserved email or security questions. Password Reset is disabled by default.
If this is not enabled, the password can only be reset on local interface.
When CGI is enabled, a third-party platform can connect to this Device through the CGI protocol.
When ONVIF is enabled, other devices can connect to this Device through the
ONVIF protocol.
Set private protocol authentication mode, security mode and compatibility mode are selectable.
Security mode: System uses safer private protocol.
Compatibility mode: System is compatible with various private protocols.
Click Save .
9.7.4
Setting Firewall
Set different firewall types to guarantee the cyber security. Disable PING and half-open connection.
Disable PING: No reply to PING request.
Disable half-open connection: Enable the function to prevent the device from from being attacked by hackers and not working properly.
128
In the live view interface, click , select SECURITY>FIREWALL.
Click to disable PING and half-open connection as needed.
Firewall
User’s Manual
Click Save .
9.7.5
HTTPS
HTTPS guarantees the security of user information, device security, and data communication with reliable and stable technological means. After installing the certificate, you can use the HTTPS on the PC to access the Device.
9.7.5.1
Certificate Installation
The system provides two certificate installation methods as follows. Select the most suitable method based on your own needs.
Installing manually created certificate.
Installing signature certificate.
9.7.5.1.1
Installing Created Certificate
Install certificates by manually creating them, including creating certificates on the Device, and downloading and installing root certificates from PC.
For first-time use of HTTPS or after changing the IP address of the Device, you need to create server certificates and install root certificates.
After creating server certificate and installing root certificate, if you use another PC to log in to the Device web, download and install root certificate on the new PC, or copy the downloaded certificate to the new PC.
129
Select SECURITY > CREDENTIAL .
Credential(1)
User’s Manual
Create certificate on the Device.
1) Click Create Certificate.
Creating certificate
2) Set Country, IP/Domain, Term of Validity, and other information as needed.
Country, IP/Domain, Term of Validity are required; others are optional.
In IP/Domain, fill the IP or domain name of the Device.
3) Click OK .
The system starts creating certificate and displays information of the created
certificates. See Figure 9-82.
130
Credential(2)
User’s Manual
Download root certificate.
1) Click .
2) Click Save File and select the path to store files.
3) Click Save .
The system starts downloading certificate file.
Install the root certificate on the computer.
1) Double-click the certificate file.
2) Click Open .
3) Click Install Certificate.
4) Follow on-screen instructions to import certificate.
Click OK to complete certificate installation.
9.7.5.1.2
Installing signature certificate
Install signature certificates by uploading them.
Before installation, make sure you have obtained safe and valid signature certificate.
Procedures
Select SECURITY > CREDENTIAL .
Click Install Signature Certificate .
131
Installing signature certificate
User’s Manual
Click Browse to select the certificate and certificate key files.
Click Install .
Install the root certificate on the PC. For details, see Step 4 in Installing Created Certificate.
This root certificate is the one obtained with signed certificate.
9.7.5.2
Enabling HTTPS
After installing the certificate and enabling HTTPS, you can use the HTTPS on the PC to access the
Device.
Select SECURITY > CREDENTIAL .
Click to enable HTTPS.
Click Save to save the settings.
After saving the settings, you can use HTTPS to log in to the web interface.
Enter https:://IP address::port”, and then press Enter .The login interface is displayed.\
IP address is Device IP or the domain name.
Port refers to device HTTPS port number. If the HTTPS port is the default value 443, you can directly access Device by entering https:// IP address.
9.7.5.3
Uninstalling Certificate
Uninstall the installed certificate.
After uninstallation, the HTTPS function becomes unusable.
Select SECURITY > CREDENTIAL .
132
Credential(1)
User’s Manual
Click Uninstall .
Prompt interface
Click OK to uninstall the installed certificate.
133
User’s Manual
10
Operation and Maintenance Management
You can operate and maintain the Device running environment to guarantee proper operation.
Log Search
Logs record all kinds of system running information. To ensure normal operation of the system, regularly view the log and fix the problems in time.
Clear the logs may make it impossible to find out the cause of the system abnormality, please operate carefully.
10.1.1
System log
You can search or export the system log, including the running status log, file management log, hot spare HDD log, HDD detection log, and timed task log.
Click on the homepage, and select MAINTAIN > LOG > System .
Set the search conditions, including level, type, and date of the system log.
Click Reset if you want to restore the search conditions to default settings.
Click Search .
System log
Insert the USB storage device, and then click to export the log information
Click Clear all to clear all system logs.
134
User’s Manual
10.1.2
User Operation Log
You can search or export user operation log, including user operations or settings.
Select MAINTAIN > LOG > User Operation .
Set the search conditions, including type, username, and date.
Click Reset if you want to restore the search conditions to default settings.
Click
Click Search .
to set the devices you want to search.
User operation log
Insert the USB storage device, and then click to export the log information.
Click Clear all to clear all user operation logs
Clear the logs may make it impossible to find out the cause of the system abnormality, please operate carefully.
10.1.3
Event Log
You can search or export the alarm event log.
Select MAINTAIN > LOG > Event .
Set the search conditions, including type, username, and date.
Click Reset if you want to restore the search conditions to default settings.
Click Search .
135
Event log
User’s Manual
Choose the log and click to export the log information to the USB storage device.
Click Clear all to clear all event logs.
Clear the logs may make it impossible to find out the cause of the system abnormality, please operate carefully.
10.1.4
Link Log
Query or export linkage log, including user log-out, session hijacking, session blasting, and more.
Select MAINTAIN > LOG > Link .
Set the search conditions, including type, username, and date.
Click Reset if you want to restore the search conditions to default settings.
Click Search .
Link Log
136
User’s Manual
Choose the log and click Export to export the log information to the USB storage device.
Click Clear all to clear all link logs.
Clear the logs may make it impossible to find out the cause of the system abnormality, please operate carefully.
Online User
Search the information of the users who conducts remote access to the device. You can also block a user for a period of time. The blocked user will not be allowed to access the device during the block time.
Block own user or admin is not allowed.
Select MAINTAIN > ONLINE USER .
The user information is displayed in the list.
Online User
Select the user you want to block and click Block .
Block
Set block time, the default time is 30 minutes.
137
User’s Manual
Click OK to save the settings.
Maintenance
Device maintenance refers to operations such as rebooting the Device, restoring default settings, or system upgrades. These operations aim to clear failures or errors from the running system and make the Device work more efficiently.
10.3.1
Upgrade
You can upgrade the system version by importing upgrade files. Upgrades files in .bin format.
During upgrading, do not disconnect from power and network, and reboot or shut down the
Device.
Make sure the update file is right. Improper upgrade file might result in device error.
10.3.1.1
Host upgrade
The USB device with upgrade files is connected to the Device.
Procedures
Select MAINTAIN > DEVICE MAINTAIN > Upgrade > Host .
Host upgrade
Click Browse and select the upgrade file.
Version upgrade, module upgrade and keyboard need to be done separately.
Click Upgrade Now .
The system starts upgrading. After the upgrade, the Device automatically reboots.
138
10.3.1.2
Upgrading Cameras
The USB device with upgrade files is connected to the Device.
Procedures
Select MAINTAIN > DEVICE MAINTAIN > Upgrade > Camera Upgrade .
Camera upgrade
User’s Manual
Select the camera to be upgraded.
Click File upgrade.
Close recording before upgrade; otherwise the upgrade might fail.
Click Upgrade Now .
The system starts upgrading. The camera restarts automatically after the upgrade finishes.
10.3.2
Factory Default
If the Device runs slowly and has configuration errors, try restoring default settings.
All settings are lost if you restore default settings. Be careful.
Select MAINTAIN > DEVICE MAINTAIN > Reset Default .
Restoring default settings
Click Factory Default .
The system starts restoring default settings. After the restoration, the Device automatically reboots.
139
User’s Manual
10.3.3
IMP/EXP
You can export configuration files to a local PC or USB storage device for backup. When the configuration is lost due to abnormal operation, import a configuration backup to quickly restore system settings.
Importing Configurations
Select MAINTAIN > DEVICE MAINTAIN > IMP/EXP .
IMP/EXP
Click Browse and select the configuration files that you want to import.
Click Config Impor t.
Exporting Configurations
Click Configuration Export and you can export configuration files to a local PC or USB storage device. Saving path might vary according to interfaces you operate on, and the actual interface shall prevail.
On local interface, you can select where to save files.
On web interface, files are stored in the default path set up in the browser.
In local operations, connect the USB storage device to the Device.
Notification Center
Various unprocessed alarm massages are displayed in real time on the Notification Center interface.
There is an icon in front of each failure alarm.
Select MAINTAIN > Notification Center .
Perform operations on notifications.
Click Refresh to update alarm notifications.
Restore notifications: Click Restore , and the Device automatically attempts to restore from X-ray failure.
Restoring is only available for X-ray failure.
140
User’s Manual
Device Diagnosis
10.5.1
X-ray System Diagnosis
Detector Diagnosis
The detector diagnosis module displays the grayscale curve of detection points. You can click Start emission and Stop emission in X-ray Source Control to observe the curve amplitude, and determine whether the detector is in good quality and whether the position of each detection board is adjusted properly.
Click Start emission , the X-ray is generated and the curve rises. Click Stop emission , the
X-ray emission is stopped and the curve falls.
Click Left , Stop , and Right , the conveyor rotates forward, stops, or rotates backward.
Curve judgment standards:
The number of detection boards and the number detection points vary with the devices.
The curve amplitude shall be between 2000–6000. The whole curve is a relatively stable line chart.
The voltage and current of the X-ray generator emission are adjusted according to the factory settings.
X-ray Generator Diagnosis
Diagnose whether the voltage and current are normally displayed when X-ray is triggered normally for a preliminary judgment on the X-ray generator.
Click Start emission , the X-ray is generated, and the voltage and current start to be displayed.
Click Stop emission , the X-ray emission is stopped, and the voltage and current stop being displayed. The specific voltage and current vary from the settings of different models of
devices.
Click Left , Stop , and Right , the conveyor rotates forward, stops, or rotates backward.
141
Profile view X-ray generator diagnosis
User’s Manual
Take 6550A series security screening machine as an example, currently the number of detector is 10, the interfaces might vary from different security screening machines according to its different number of detectors.
Single-view server: Only displays one view.
10.5.2
IR Sensor Diagnosis
Diagnose the working status of the two pairs of IR sensors at the entrance and the other two pairs at the exit.
Select MAINTAIN > Device Diagnosis > IR Sensor Diagnosis .
IR Sensor Diagnosis
Test IR sensors.
142
User’s Manual
Test method 1: Block the IR sensors at the entrance with an opaque object, and there will be a square wave at high level at A side. The longer the blocking, the wider the square wave, which is normal. Use the same method to test B side.
Method 2: Place an object to be inspected flat on the conveyor, and then click Right .
It is normal when there is a square wave at high level at A side. Click Left . It is normal when there is a square wave at high level at B side.
IR sensor diagnosis
A side represents the entrance direction, and B side represents the IR sensor position
(optional).
The green line indicates the power-saving IR sensor, and the red line indicates package sensor inside the tunnel.
Horizontal axis: Time.
Vertical axis: Connection status.
Low level without blocking and high level with blocking.
There is a high level pulse when an object passes.
10.5.3
One-Click Diagnosis
Exit or cancel is not available during diagnosis.
Use one-click diagnosis to determine whether the key components of the Device work normally.
Select MAINTAIN > Device Diagnosis > One-Click Diagnosis .
When one-click diagnosis is triggered for the first time, the system doesn’t display corresponding report.
One-Click Diagnosis
143
Click Start Diagnosis .
Confirmation information before starting diagnosis.
User’s Manual
Click OK to start diagnosis.
indicates diagnosing.
indicates to be diagnosed.
Diagnosis progress
After diagnosis is completed, click View Report to view the report details.
Related Operations
The list of one-click diagnosis reports is arranged in a reverse chronological order.
Each page can display 30 or 50 reports. When the maximum display number of the page is exceeded, you need to turn pages for check.
Logout/Rebooting/Shutting
You can log out from the current user account, and reboot or shut the Device.
You can only use the local key to shut down the Device.
144
User’s Manual
Logging out
On the homepage, click
Rebooting
and select Log Out .
On the homepage, click window. Click OK and the Device reboots.
, select Reboot , and the system prompts confirmation
Shutting
Directly plug off the power supply can result in the loss of unsaved files (recordings, pictures).
Method A as follows is recommended.
One-key shutdown, turn the key switch counterclockwise to the "OFF" state, the software exits, and the system power supply is disconnected.
145
User’s Manual
11
FAQ2
The conveyor works normally, but the baggage image is not generated
Possible cause
Abnormal scanning configuration of the device.
Expired device license.
Troubleshooting:
1.
Check whether the current scanning configuration is single direction scanning. If it is set as single direction scanning and the package is reversed, the images of scanned image are not generated;
2.
Configuration: Select MENU> BAGGAGE MANAGEMENT > SECURITY SCREENING , set the scanning mode, the default mode is double direction forward mode.
3.
If the device license expires, select MENU>MAINTAIN > DEVICE MAINTAIN>UPDATE to check the validity period of the license.
146
User’s Manual
If the errors cannot be eliminated according to the above steps, please contact professional maintenance personnel.
The conveyor suddenly stops during the working process.
Possible cause:
Power saving mode is on.
Abnormal damage of the motor.
Troubleshooting:
If the power saving mode is on, the conveyor will automatically stop if no package passes within 15 seconds; select MENU>BAGGAGE>MANAGEMENT>SECURITY SCREENING to confirm whether the power saving mode is on. If it is on, turn it off.
147
Mode switch
User’s Manual
If the errors cannot be eliminated according to the above steps, please contact professional maintenance personnel.
No AI overlay after scanning baggage.
Possible cause:
AI overlay is disabled.
Check the detection config, partial prohibited items recognition enables.
Expired device license.
Troubleshooting:
1.
Go back to the live view interface to enable AI overlay.
Live view interface
2.
Check the recognition switches of the prohibited items corresponded to the detection config enable or not. Each prohibited item can be recognized only when its recognition switch is on.
Select Menu > BAGGAGE MANAGEMENT > DETECTION CONFIG .
148
Configuring Detection Parameters
User’s Manual
3.
Expired device license. Select MENU>MAINTAIN > DEVICE MAINTAIN>UPDATE to check the validity period of the license.
Operation and Maintenance Management
If the faults can not be eliminated or not involved according to the above procedures, please contact professional maintenance personnel.
149
User’s Manual
Dimension Diagram of Applicable
Models
Appendix Figure 1-1 ISC-M5030A
150
Appendix Figure 1-2 ISC-M6550A
User’s Manual
151
User’s Manual
Terminologies and Abbreviations
Name
DDNS
DHCP
DNS
HDMI
HTTPS
IP
NTP
MTU
S.M.A.R.T
VGA
Appendix Table 2-1 Terminologies and Abbreviations
Description
Dynamic Domain Name System, where the dynamic IP addresses of the user are mapped to a fixed DNS server. Each time, when the user connects to the network, the client transmits the dynamic addresses of the host to the server application on the carrier host.
This server application provides DNS service and realize dynamic domain name analysis.
In short, with DDNS, the user does not need to record the ever changing IP address. Just access or login to the Device or URL by the domain name.
Dynamic Host Configuration Protocol, a local area network protocol used to automatically assign IP addresses within a network or a network service provider. DHCP is a unified means for managing IP address of PC.
Domain Name System, used to store the domain names and IP addresses of all hosts in a network, and capable of transforming domain names to IP addresses.
High Definition Multimedia Interface, a proprietary digital interface for transmitting audio signals and video signals simultaneously.
Hyper Text Transfer Protocol over Secure Socket Layer, a HTTP channel for security purpose. HTTPS defines the rules for secure communication over browsers and Internet servers. Its communication protocol with webpages is encrypted.
Internet Protocol.
Network Time Protocol (NTP) is a protocol to synchronize computer time. It adopts wireless network protocol UDP, so that the computer time synchronizes with the server or the time source. It is to provide time correction of high accuracy.
Maximum Transmission Unit (MTU) refers to the maximum data packet amount (byte) on one layer of the communication protocol.
Self-Monitoring Analysis and Reporting Technology (S.M.A.R.T) is a technical standard to detect HDD drive status and report potential problems.
Video Graphics Array, a video transmission standard featuring high resolution, fast display, and diversified colors.
152
User’s Manual
RAID
RAID is an abbreviation for Redundant Array of Independent Disks. It is to combine several independent HDDs (physical HDD) to form a HDD group (logic HDD).
Comparing with one HDD, RAID provides more storage capacity and data redundancy. The different redundant arrays have different RAID level. Each RAID level has its own data protection, data availability and performance level.
Appendix Table 3-1 RAID level
RAID Level Description
RAID 0 is also known as Striping.
Min. HDDs
RAID 0
RAID 0 is to save the continued data fragmentation on several HDDs. It can process the read and write at the same time, so its read/write speed is N (N refers to the HDD amount of the RAID 0) times that of a single
HDD. RAID 0 does not have data redundant, so one HDD damage might result in data loss that cannot be restored.
2
RAID 1
RAID 5
RAID 6
RAID 10
RAID 1 is also known as Mirror or Mirroring.
RAID 1 data is written to two HDDs equally, which guarantee the system reliability and can be repaired. RAID 1 read speed is almost close to the total volume of all HDDs. The write speed is limited by the slowest HDD.
At the same time, the RAID 1 has the lowest HDD usage rate. It is only
50%.
RAID 5 stores data and the corresponding parity check information to each HDD of the RAID 5 group. The data and corresponding parity check information are stored in different HDDs. If one HDD of the RAID 5 is damaged, the system uses the residual data and corresponding parity check information to restore damaged data. This guarantees data intactness.
Based on the RAID 5, RAID 6 adds one parity check verification HDD. By adopting different algorithms, the two mutually independent parity systems guarantee high data reliability, to the point that even damages to two HDDs at the same time would not result in data loss. Compared to RAID 5, the RAID 6 needs to allocate larger HDD space for parity check information, so its read/write is even worse.
As the combination of RAID 1 and RAID 0, RAID 10 is strong in reading and writing data and guarantees data security. It uses the highly efficient reading and writing performance of RAID 0 and the powerful data protection and restoration capacity of RAID 1. However, RAID 10 is equally low in usage efficiency as RAID1.
2
3
4
4
RAID Capacity
The calculation of RAID capacity is shown as follows. capacityN refers to the HDD ( with Min capacity) used to create the corresponding RAID.
153
RAID Level
RAID 0
RAID 1
RAID 5
RAID 6
RAID 10
RAID 50
RAID 60
Appendix Figure 3-2 Calculation of RAID capacity
Total Capacity of N HDD
Total capacity of current RAID group
Min (capacityN)
(N-1) × min (capacityN)
(N-2) × min (capacityN)
(N/2) × min (capacityN)
(N-2) × min (capacityN)
(N-4) × min (capacityN)
User’s Manual
154
User’s Manual
Total HDD Capacity Calculation
HDD capacity calculation formula:
Total HDD capacity (M) = Number of channels× recording time (h) × Used HDD space each hour
(M/h)
The equation for calculating the recording time can be obtained through above equations.
Recording time (H) =
Total HDD capacity ( M )
Number of channels × Used HDD space each hour ( M / H )
For example: The recording of a single channel uses 200 M HDD space per hour. Use 4-channel device to make 24-hour continuous recording in every day of one month (30 days), the required
HDD space is: 4 channels× 30 days× 24 h× 200 M/h = 576 GB. Typically five 120 GB HDDs, or four
160 GB HDDs are needed.
According to the above formula, at different stream values, recording file size of 1 channel in 1 hour is shown as follows (for your reference):
Appendix Table 4-1 Recording file size
Max. Bit Stream
96 K
File Size
42 M
Max. Bit Stream
128 K
File Size
56 M
160 K
224 K
70 M
98 M
192 K
256 K
84 M
112 M
320 K
448 K
640 K
896 K
1280 K
1792 K
140 M
196 M
281 M
393 M
562 M
787 M
384 K
512 K
768 K
1024 K
1536 K
2048 K
168 M
225 M
337 M
450 M
675 M
900 M
155
User’s Manual
Cybersecurity Recommendations
Cybersecurity is more than just a buzzword: it’s something that pertains to every device that is connected to the internet. IP video surveillance is not immune to cyber risks, but taking basic steps toward protecting and strengthening networks and networked appliances will make them less susceptible to attacks. Below are some tips and recommendations from Dahua on how to create a more secured security system.
Mandatory actions to be taken for basic device network security:
1.
Use Strong Passwords
Please refer to the following suggestions to set passwords.
The length should not be less than 8 characters.
Include at least two types of characters; character types include upper and lower case
letters, numbers and symbols.
Do not contain the account name or the account name in reverse order.
Do not use continuous characters, such as 123, abc, etc.
Do not use overlapped characters, such as 111, aaa, etc.
2.
Update Firmware and Client Software in Time
According to the standard procedure in Tech-industry, we recommend to keep your device
(such as NVR, DVR, IP camera, etc.) firmware up-to-date to ensure the system is equipped
with the latest security patches and fixes. When the device is connected to the public network, it is recommended to enable the“auto-check for updates” function to obtain timely information of firmware updates released by the manufacturer.
We suggest that you download and use the latest version of client software.
"Nice to have" recommendations to improve your device network security:
1.
Physical Protection
We suggest that you perform physical protection to device, especially storage devices. For example, place the device in a special computer room and cabinet, and implement well-done access control permission and key management to prevent unauthorized personnel from carrying out physical contacts such as damaging hardware, unauthorized connection of removable device (such as USB flash disk, serial port), etc.
2.
Change Passwords Regularly
We suggest that you change passwords regularly to reduce the risk of being guessed or cracked.
3.
Set and Update Passwords Reset Information Timely
The device supports password reset function. Please set up related information for password reset in time, including the end user’s mailbox and password protection questions. If the information changes, please modify it in time. When setting password protection questions, it is suggested not to use those that can be easily guessed.
4.
Enable Account Lock
The account lock feature is enabled by default, and we recommend you to keep it on to guarantee the account security. If an attacker attempts to log in with the wrong password several times, the corresponding account and the source IP address will be locked.
5.
Change Default HTTP and Other Service Ports
We suggest you to change default HTTP and other service ports into any set of numbers between 1024–65535, reducing the risk of outsiders being able to guess which ports you are
156
User’s Manual using.
6.
Enable HTTPS
We suggest you to enable HTTPS, so that you visit Web service through a secure communication channel.
7.
MAC Address Binding
We recommend you to bind the IP and MAC address of the gateway to the device, thus reducing the risk of ARP spoofing.
8.
Assign Accounts and Privileges Reasonably
According to business and management requirements, reasonably add users and assign a minimum set of permissions to them.
9.
Disable Unnecessary Services and Choose Secure Modes
If not needed, it is recommended to turn off some services such as SNMP, SMTP, UPnP, etc., to reduce risks.
If necessary, it is highly recommended that you use safe modes, including but not limited to the following services:
SNMP: Choose SNMP v3, and set up strong encryption passwords and authentication
passwords.
SMTP: Choose TLS to access mailbox server.
FTP: Choose SFTP, and set up strong passwords.
AP hotspot: Choose WPA2-PSK encryption mode, and set up strong passwords.
10.
Audio and Video Encrypted Transmission
If your audio and video data contents are very important or sensitive, we recommend that you use encrypted transmission function, to reduce the risk of audio and video data being stolen during transmission.
Reminder: encrypted transmission will cause some loss in transmission efficiency.
11.
Secure Auditing
Check online users: we suggest that you check online users regularly to see if the device is logged in without authorization.
Check device log: By viewing the logs, you can know the IP addresses that were used to log in to your devices and their key operations.
12.
Network Log
Due to the limited storage capacity of the device, the stored log is limited. If you need to save the log for a long time, it is recommended that you enable the network log function to ensure that the critical logs are synchronized to the network log server for tracing.
13.
Construct a Safe Network Environment
In order to better ensure the safety of device and reduce potential cyber risks, we recommend:
Disable the port mapping function of the router to avoid direct access to the intranet devices from external network.
The network should be partitioned and isolated according to the actual network needs. If there are no communication requirements between two sub networks, it is suggested to use VLAN, network GAP and other technologies to partition the network, so as to achieve the network isolation effect.
Establish the 802.1x access authentication system to reduce the risk of unauthorized access to private networks.
Enable IP/MAC address filtering function to limit the range of hosts allowed to access the device.
157
User’s Manual
More information
Please visit Dahua official website security emergency response center for security announcements and the latest security recommendations.
158
User’s Manual
159
Pakua