- Industrial & lab equipment
- Electrical equipment & supplies
- Power generators
- NORTHSTAR
- PTO Generator
- Owner's manual
advertisement
M165951G.5
ITEM NUMBER: 165951
SERIAL NUMBER: _____________
Owner’s Manual
Instructions for Installation/Set-up, Operation, Servicing, & Storage
Portable Outdoor Use-Only, Power Take-Off (PTO) Generator
7,200 Watt Continuous (7,800 Watt Surge) Capacity
Can be used to power individual appliances plugged directly into the generator’s outlets, or as a back up
connection to a building’s power supply (via a professionally installed UL-approved transfer switch).
WARNING
READ and UNDERSTAND this manual completely before using the generator! Failure to properly set up, operate, and maintain this generator could result in serious injury or death from carbon monoxide poisoning, electric shock, entanglement, fire, or burns . In addition, PTO shaft and generator can become airborne and cause severe injury if improperly secured. In particular, be aware of the following hazards:
CO Poisoning
The running tractor engine gives off carbon monoxide, a poisonous gas that can kill you. You CANNOT smell it, see it, or taste it.
•
ONLY run tractor and generator OUTDOORS and AWAY from building air intakes. NEVER run inside any enclosed or semienclosed spaces, including homes, basements, garages, sheds, and boxes. These spaces can trap poisonous gases, EVEN if you run a fan or open windows.
•
Install carbon monoxide alarms inside nearby structures/buildings (battery-operated, or plug-in with battery backup).
Electric shock / Electrocution
•
High voltage electricity from generator can kill. DO NOT operate in wet locations. Be sure generator is properly grounded. Use only
UL-listed, outdoor-rated grounded GFCI-equipped extension cords of proper size.
• NEVER plug the generator directly into a wall outlet. ANY connection to a building’s electrical system MUST ISOLATE THE
GENERATOR FROM UTILITY POWER via a UL-approved transfer switch installed by a licensed electrician. Otherwise, back feed from the generator into the power grid could kill utility workers.
Fire
•
DO NOT overload generator (per rated capacity), and OPERATE ONLY in an area with adequate cooling ventilation so generator does not overheat and possibly cause fire. Keep all objects at least 7’ from generator vent openings. Refer to tractor manual for minimum safe clearance distance between hot tractor exhaust and nearby combustible materials and structures.
•
ALWAYS keep a fire extinguisher rated “ABC” nearby.
Power Take-Off (PTO)
•
Failure to properly mount and secure the generator may cause the unit to flip violently during use, which could cause severe injury to the operator or bystanders, or damage to surrounding objects.
•
Never operate the generator without proper PTO guarding, including a freely rotating shaft guard as well as tractor and generator shields at each end. Clothing or hair can become rapidly entangled in unguarded rotating PTO shaft or connections, resulting in serious injury or death.
•
•
Make sure PTO driveline shaft is securely locked at both ends. An unlocked PTO shaft can whip or become dangerously airborne.
STOP!
CHOOSE THE RIGHT GENERATOR FOR YOUR NEEDS.
See the “Power load Planning & Management” section of this manual to determine your power load requirements and then compare to the generator’s rated capacity.
INSPECT COMPONENTS : Closely inspect to make sure no components are missing or damaged. See the “Unpacking & Delivery
Inspection” section for instructions on whom to contact to report missing or damaged parts.
MOUNTING IS REQUIRED . You will need to mount this PTO generator to either a (reinforced?) concrete slab or a PTO trailer. See the “About Your Generator” and “Installation/Initial Set-Up” sections for more information on this requirement.
ARRANGE FOR PROFESSIONAL INSTALLATION of a transfer switch if you will be connecting the generator to your building’s electrical system.
See the “Installation/Initial Set-Up” section for more information about this requirement.
Any Questions, Comments, Problems, or Parts Orders
Call NorthStar Product Support 1-800-270-0810
Hazard Signal Word Definitions
2
Table of Contents
Hazard Signal Word Definitions ................................................................................................. 2
About Your Generator ................................................................................................................. 4
Specifications ................................................................................................................................. 6
Safety Label Locations .................................................................................................................. 7
Machine Component Identification ............................................................................................. 8
Power Load Planning & Management ........................................................................................ 10
Installation / Initial Set-Up:
1. Unpacking & Delivery Inspection .......................................................................................... 12
2. Planning the Power Load ........................................................................................................ 13
3. Set-up as a PORTABLE or BUILDING BACK-UP Power Source ...................................... 13
4. Selecting a Suitable Site ......................................................................................................... 16
5. Mounting the Generator ......................................................................................................... 18
6. Grounding the Generator ........................................................................................................ 20
Operation:
1. General Safety Rules for Operation ....................................................................................... 21
2. Preparing for Operation .......................................................................................................... 22
3. Connecting to the Tractor ....................................................................................................... 24
4. Starting the Generator ............................................................................................................. 25
5. Connecting Loads ................................................................................................................... 26
6. Stopping .................................................................................................................................. 28
7. Storage & Exercise ................................................................................................................. 28
Maintenance & Repair .................................................................................................................. 29
Troubleshooting ............................................................................................................................. 31
Summary of Important Safety Information for Operation ....................................................... 32
PTO Generator Exploded View ................................................................................................... 35
Wiring Diagram ............................................................................................................................. 36
PTO Gearbox Exploded View ...................................................................................................... 37
Limited Warranty ......................................................................................................................... 39
California Proposition 65 Information ........................................................................................ 40
3
About Your Generator
Thank you for purchasing your NorthStar PTO generator!
About Your Generator
This PTO-driven, portable generator is designed to provide up to 7200 Watts of electrical power (7200 watts continuous, 7800 watts Surge).
Connected to your tractor’s power take-off
(PTO)*, the generator can supply power:
1.
As a portable power source. You can plug appliances directly into the generator’s electrical outlets.
2.
As a back-up, standby power source for a building. A licensed electrician can connect the generator to your building’s electrical system via the installation of an UL-approved transfer switch.
(See the “Installation & Initial Set-up” section of this manual to learn more about specific requirements and precautions relating to wiring the generator to your building’s electrical system.)
* Your tractor’s PTO must produce a minimum of 14 HP at 540 RPM.
You must select a generator adequately sized for your power needs.
You need to determine the power needs of all the appliances/tools you wish to power at the same time and choose a generator rated to provide at least that power level. See the “Power Load Planning &
Management” section of this manual to determine your specific power load requirements and then compare them to this generator’s rated capacity. You must not overload the generator.
Overloading will cause damage to the generator and attached electrical devices, and may also result in fire.
This generator must be mounted on a reinforced concrete slab or a PTO generator trailer, so that the generator will not flip during use due to the rotational force of the PTO.
The slab or trailer must be of adequate size and strength to withstand operating torque without flipping or structural failure. A trailer designed specifically for use with PTO generators rated up to 60,000 Watts is available from NorthStar -- Item #165959. More detailed information about mounting can be found in the “Installation / Initial Set-Up” section of this manual.
Be sure to read about site selection and grounding requirements for running this generator.
More detailed information can be found in the “Installation & Initial Set-up, Steps
5 & 6” of this manual.
Optional accessories available from NorthStar include PTO drivelines, UL-approved transfer switches and extension cords. Contact NorthStar Product Support at 1-800-270-0810 with questions about optional accessories or to order.
Read this Manual
WARNING
Improper use or maintenance of this generator can result in serious injury or death from carbon monoxide poisoning, electric shock/electrocution, entanglement, flying objects,
fire, or burns. In addition, PTO shaft and generator can become airborne and cause severe injury if improperly secured.
Read this manual completely before using the generator and follow all instructions and safety rules.
4
About Your Generator (cont’d)
You must follow all instructions and safety precautions presented throughout this manual. A summary of important safety information can be found at the end of the manual. Keep this manual for reference and review.
Proper preparation, operation, and maintenance will result in operator safety as well as best performance and long life of the generator. Failure to follow the instructions in this manual for proper mounting, set-up, operation, and maintenance of the generator will void the manufacturer’s warranty.
Before using, the user shall determine the suitability of this product for its intended use and assumes liability therein. The purchaser and/or user shall assume liability for any modification and/or alterations of this equipment from original design and manufacture, or for any nonstandard application, or for use as a subcomponent in another piece of equipment.
NorthStar is constantly improving its products. The specifications outlined herein are subject to change without prior notice or obligation.
Contact NorthStar Product Support at 1-800-270-0810 for any questions about the appropriate use of this generator.
Warranty Registration
Please fill out and submit the warranty registration card so that we have your contact information for any future product literature or replacement parts you may need.
ATTENTION:
All Rental Companies and Private Owners who loan this equipment to others!
All persons to whom you rent/loan this generator must have access to and read this manual .
Keep this owner’s manual with the generator at all times and advise all persons who will operate the machine to read it. You must also provide personal instruction on how to safely operate the generator and remain available to answer any questions a renter/borrower might have.
5
Specifications – Item #165951
Gear Box
Gear Ratio
Gear Oil
Oil Capacity
Dimensions
Length
Width
Height
Gross Weight
SPECIFICATIONS
Item Number
Maximum Output
Continuous Output
Voltage
Phase
Frequency
Power Factor
Minimum PTO HP
Minimum Operating Torque
Input Shaft
120V Receptacle
120/240V Receptacle
Circuit Breaker
165951
7800 Watts (W)
7200 Watts (W)
120 / 240 Volt (V)
Single phase (4-wire)
60.0 Hertz (Hz)
1.0
14 HP at 540 RPM
101.7 pound-foot
13/8” Diameter, 6 spline
(2) 20 Amp (A) (NEMA 5-20R)
(1) 30 Amp (A) locking device (NEMA L14-30R)
(2) 20 Amp (A) thermal, push to reset style
(1) 30 Amp (A) thermal magnetic
1:7
SAE 90W
0.75 Qt. (.82 L)
25.25”
12.50”
17.25”
110 lbs.
6
Safety Label Locations – Item #165951
DANGER WARNING
Poisonous Gas Hazard
Tractor engines give off carbon monoxide, an odorless gas that can kill you in minutes.
ONLY run tractor & generator
OUTDOORS and AWAY from building
air intakes.
Never run inside homes, garages, or
sheds, EVEN if you run a fan or open
Electric Shock/Electrocution Hazard
High voltage from generator can kill.
NEVER connect generator directly into a wall outlet.
ANY connection to a building's electrical system MUST ISOLATE
GENERATOR FROM UTILITY
POWER via a transfer switch.
Be sure generator is properly grounded.
Use only outdoor-rated, grounded
GFCI extension cords of proper size.
A Fire Hazard can arise from:
Overloading the generator
Lack of cooling ventilation
Contact with hot tractor exhaust
DO NOT overload generator.
OPE RATE ONLY with adequate cooling ventilation. Keep all objects at least
7 feet from generator vent openings.
Keep tractor exhause away from all combustible objects.
ALWAYS keep a fire extinguisher nearby.
windows.
Install carbon monoxide alarms inside
nearby structures/buildings.
DO NOT operate in wet locations.
Read Owner's Manual completely before using. Serious injury or death can result if safety directions are not followed.
DANGER
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.
NEVER use inside a home or garage. EVEN IF doors and windows are open.
Only use OUTSIDE and far away from windows, doors, and vents.
DANGER!
Rotating Driveline/PTO Hazard
Contact with rotating driveline can cause death!
Driveline guard, plus tractor and generator shields must be in place. Driveline guard must turn freely and independently on driveline.
Accidental contact with rotating driveline will cause hair or clothing near
rotating shaft to become rapidly entangled.
Driveline must be securely locked at both ends.
An unlocked PTO shaft can whip or become dangerously airborne.
Generator must be properly mounted in accordance with instructions.
Improper mounting may cause generator to flip dangerously during use.
Always make sure safety labels are in place and in good condition. If a safety label is missing or not legible, order new labels or unsafe operation could result.
To order replacement safety labels, call NorthStar Product Support at 1-800-270-0810.
On-Product Warning Labels
Part numbers
779781
779770
779407
Description
General Warning
PTO Warning
Danger Carbon Monoxide
7
Machine Component Identification - Item #165951G.4
Ref. Description
4
5
6
7
1
2
3
8
Alternator
Grounding Screw
Isomounts
30A Circuit Breaker
120V Receptacle
20A Circuit Breaker
120/240V Locking Receptacle
Gearbox
Figure 1 (Ref 1-12)
Ref. Description
9 Filler/Breather Plug
10 Implement Shield
11 Fan Vents
12 Mounting Holes
13 Voltmeter
14 13/8” Diameter 6 Spline Input Shaft
15 Oil Fill Sight Glass
16 Oil Drain Plug
8 Figure 2 (Ref 13-16)
Machine Component Identification – Item #165951G.4 (cont’d)
REFERENCE GUIDE
Reference 1 – Alternator The generator head produces energy.
Reference 2
– Grounding Screw
Use to ground the generator to a copper pipe or rod that is driven into moist soil.
Reference 3
– Isomounts
Reduces vibrations transmitted to the control box.
Reference 4 – 30A Circuit Breaker Thermal magnetic breaker protects against over currents and short circuits.
Reference 5 – 120V Receptacles One 120V 20A straight blade receptacle duplex (two receptacles in a common housing). National Electrical Manufacturer’s
Association (NEMA) number 5-20R.
Reference 6
– 20A Circuit Breaker
(Qty 2) Push to reset style thermal breakers protect against over currents.
Reference 7 – 120/240V Locking 30A receptacle, NEMA L14-30R.
Receptacle
Reference 8 – Gearbox 1:7 gear ratio.
Reference 9 – Filler/Breather Plug Fill oil here; use SAE 90W gear oil.
Reference 10
– Implement Shield
Never operate generator without shield in
Reference 11
Reference 12
– Fan Vents
– Mounting Holes place.
Never block the vent slots or insert objects through the slots. The closest object should be at least 3 feet away from the vents.
Use these locations to mount the generator in place with 5/8” grade 5 bolts.
Reference 13 – Voltmeter Needle should be in green area during all generator load conditions. The black line in the center of the green area indicates 120V.
During no load conditions, the needle should
Reference 14 – 1-3/8” Diameter 6 be at or above the black line.
Requires 14 HP or greater at 540 RPM.
Spline Input Shaft
Reference 15 – Oil Fill Sight Glass When oil is even with the red dot, the oil level is correct. Check oil level daily.
Reference 16
– Oil Drain Plug
Remove to drain oil from gearbox.
9
Power Load Planning & Management
WARNING
NEVER exceed the rated wattage capacity of your generator.
OVERLOADING may cause SERIOUS DAMAGE to the generator and attached electrical devices, and may result in fire.
Your generator MUST BE SIZED PROPERLY to provide both the running and starting (surge) wattage of the devices you will be powering. Before using your generator, determine the running and starting wattage requirements of all the electrical devices you will be powering simultaneously.
The sum of the running and starting wattages of the devices being powered must not exceed the continuous output rating of your generator. (The continuous output rating of your generator is listed in the “Specifications” section of this manual.) Note that:
•
Devices without electric motors such as light bulbs, radios, and televisions have the same running and starting wattage.
•
Devices with electric motors such as refrigerators, compressors, and hand tools typically require a starting wattage that is 3 to 5 times greater than the running wattage.
The running and starting wattage requirements are often listed on a device’s nameplate. If wattage is not given on the device’s nameplate, the wattage may be calculated by multiplying the nameplate voltage by nameplate amperage, Watts = Volts X Amps.
Example conversion to watts:
120 Volts X 5 Amps = 600 Watts
If only the running voltage is given on the nameplate for a device with an electric motor, the starting wattage can be approximated to be three to five times the running wattage.
Estimates for the running wattage requirements for common devices are listed in Table 4 below.
Guidance for starting wattages is provided in the table’s footnotes.
Table 4
Device
Air conditioner (12.000 BTU)
Battery charger (20 Amp)
Belt sander (3”)
Chain saw
Circular saw (6½”)
Coffee maker
Compressor (1 HP)
Compressor (3/4 HP)
Compressor (1/2 HP)
Curling iron
Dishwasher
Edge trimmer
Electric nail gun
Electric range (1 element)
Electric skillet
Running
Watts Device
1700 (a,b) Jet pump
500 Lawn mower
1000 Light bulb (100 Watt)
1200 Microwave oven
2000 (a,b) Milk cooler
1800 (a,b) Oil burner on furnace
1400 (a,b) Oil-fired space heater (140,000 Btu)
1800 (a) Oil-fired space heater (85,000 Btu)
1400 (a) Oil-fired space heater (30,000 Btu)
700 Oven
1200 Paint sprayer, Airless (1/3 HP)
500 Paint sprayer, Airless (handheld)
1200 Radio
1500 Refrigerator
1250 Slow cooker
Running
Watts
800 (a)
1200
100
700
1100 (a)
300
400
225
150
4500
600 (a)
150
200
600 (b)
200
10
Power Load Planning & Management (cont’d)
Device
Furnace fan (1/3 HP)
Running
Watts Device
1200 (a) Submersible pump (1-1/2 HP)
Running
Watts
2800 (a)
Freezer
Hair dryer
Hand drill (1”)
Hand drill (1/2”)
Hand drill (3/8”)
Hand drill (1/4”)
800 (b)
1200
1100
875
500
Submersible pump (1 HP)
Submersible pump (1/2 HP)
Sump pump
Table saw
Television
2000 (a)
1500 (a)
600 (a)
2000 (a)
500
Hedge trimmer
Home computer
Impact wrench
250
450
150
500
Toaster
Vacuum cleaner
VCR
Water Heater
Weed trimmer
(a) Hard-starting motors require 3-5 times the rated running watts
1000
250
70
3000
500
(b) For extremely hard to start loads such as air conditioners and air compressors, consult the equipment dealer to determine maximum wattage
To calculate the running and starting wattage requirements for the devices you will be powering, follow these steps:
1.
Make a list of all electrical devices you will be powering at the same time with the generator.
2.
List the greater of the running or starting wattage next to each device as obtained from the devices’ nameplate or
Table 4 . If only the running wattage for a device with an electric motor is known, the starting wattage can be estimated to be at least 3 times the running wattage.
3.
Add the wattages for all devices on your list. This total must be lower than the continuous output rating of your generator.
Example:
Device to be Powered
Light Bulb
Refrigerator – 18 Cu. Ft.
Microwave
Window AC
Sump pump (1/3 hp)
Total
Greater of
Starting/Running Wattage
75 W
1600 W
700 W
1800 W
2100 W
6275W
In this example, the generator must have a continuous output of at least 6275 W in order to power all of the devices simultaneously.
STAGGERING LOADS
You can increase the number of devices your generator can power by staggering the load on the generator. For example, you could alternately power your refrigerator and air conditioner for limited periods of time -- powering only one of the devices at a time and never powering both at the same time.
11
Installation / Initial Set-Up
There are a number of important steps required to set up your generator for initial use. These steps are:
Steps for Installation / Initial Set-Up
1.
Unpacking & delivery inspection.
2.
Planning the power load to stay within the generator’s rated capacity.
3.
Setting up generator for the type of power generation you need: a.
portable power source, or b.
connected to a building as a back-up power source.
4.
Selecting a site for using the generator.
5.
Mounting the generator.
6.
Grounding the generator.
Each of these steps is discussed in detail below:
1. Unpacking & Delivery Inspection
1.
You should inspect the generator immediately after you receive delivery.
See the “Machine Component Identification” section of this manual for a diagram of the generator and its components.
•
If you have missing or damaged components, contact Product Support at 1-800-270-0810.
2.
The gearbox is shipped with oil and a temporary shipping plug.
Filler/Breather plug a.
Remove the temporary shipping plug and replace
Shipping plug with the metal breather/oil fill plug that is in the manual bag. b.
Make sure that the gear oil level is in the middle of the sight glass, at the red dot.
Add SAE 90W gear oil as required.
Sight glass
12
Installation / Initial Set-Up
2. Planning the Power Load
Plan your power load so that you do not exceed the generator’s rated capacity.
See the “Power Load Planning & Management” section of this manual to review how to plan and manage power loads for the generator.
3. Set-up either as a BUILDING BACK-UP or PORTABLE Power Source
This generator is designed to provide up to 7200W of continuous electrical power. It can supply electricity in two ways:
1.
As a back-up, standby power source for a building. For this application, you must arrange for a licensed electrician to connect the generator to your building’s electrical system via the installation of an UL-approved transfer switch. The transfer switch must be installed in accordance with building electrical code and guidelines supplied by your power company.
2.
As a portable power source
. You can plug appliances or tools directly into the generator’s electrical outlets.
Specific requirements for each are given below.
Note: Regardless of whether you use your generator as a back-up power source connected to a building or as a portable power source, you must not overload the generator. Overloading may cause serious damage to the generator and attached electrical devices.
Using as a
Back-up Power
Source for a
Building
Contact a licensed electrician to install an UL-approved transfer switch if you want to use your generator as a back-up power source for a building.
What does a transfer switch do? It: a) Safely connects the generator to your building’s electrical system by isolating your generator from your utility company’s power lines,
AND b) Connects your generator to a critical subset of your building’s circuits that are needed for emergency power needs.
If your generator will be connected to your building’s electrical system, it
MUST ALWAYS be isolated from the utility power grid with a UL-approved transfer switch installed by a licensed electrician in compliance with all applicable building and electrical codes, and in accordance with guidelines supplied by your power company.
DANGER:
A transfer switch must be installed in order to isolate your generator from the utility power grid. If your generator is NOT properly isolated from the utility system, serious hazards will arise:
When your generator is running, its output will back feed into the utility power line and transformer that are normally used to provide you with power. The transformer will step up the current to the normal line voltage. An unsuspecting utility line worker working on what he thinks is a deactivated line could be electrocuted.
13
Installation / Initial Set-Up
Using as a
Portable Power
Source
If your generator is connected (running or not) when utility power is restored, your generator will be destroyed. It could also explode or cause fire.
In addition to isolating your generator from the utility system, the transfer switch connects your generator to a limited set of circuits in your building that have been chosen as critical to operate during a power outage.
This generator can power up to 7200 watts, which may not power your entire home or farm outbuilding -- you must work with the installing electrician to determine which devices/appliances you wish to power during an outage.
The electrician can help you determine which circuits and devices can be powered simultaneously without overloading the generator.
(See the previous section of this manual entitled “Power Load Planning &
Management” for more information on load application and selection.)
When using the generator as a portable power source, you can plug electric devices and appliances directly into the generator’s electrical outlets.
There are two different kinds of electrical outlets on the generator:
1.
One 120/240 Volt, 30 Amp locking receptacle (NEMA L14-30R locking receptacle compatible with L14-30P mating plug).
2.
One 120 Volt, 20 Amp duplex straight-blade receptacle (NEMA 5-
20R duplex receptacle compatible with NEMA 5-20P or 5-15P mating plugs).
NEMA
5-20R
NEMA
L14-30R
Duplex
(See more technical detail about these receptacles and their associated circuit breakers in the “Machine Component Identification” section of this manual.)
Make sure you plug each electrical device/appliance into the correct generator outlet based on the device’s plug configuration and voltage/amperage rating. Never exceed the amperage rating of an outlet.
14
Installation / Initial Set-Up
Extension cords may be used to power devices that are located at a distance from the generator. However, use only UL-listed, outdoor-rated, grounded extension cords of the proper size. Additionally, if using the generator in damp or highly electrical conductive areas or on construction jobsites, always use ground fault circuit interrupter (GFCI)-equipped extension cords to prevent electrical shock. Use Table 5 below to choose an adequately sized extension cord according to the amperage of the device being used and the length of the cord.
Table 5
Current/Power Maximum Extension Cord Length
Amps at
240V
10
20
30
40
50
Load
(watts)
2400
4800
7200
9600
12000
#10 Ga.
Cord
250’
125’
60’
30’
15’
#12 Ga.
Cord
150’
75’
35’
15’
*
#14 Ga.
Cord
100’
50’
25’
10’
*
#16 Ga.
Cord
75’
25’
10’
*
*
WARNING:
Use of under sized extension cords can cause electric shock, fire, or damage to connected devices. Failure to use GFCI extension cords in damp or wet conditions can result in severe electric shock or electrocution.
All extension and appliance cords must be in good condition and not worn, bare, frayed, or otherwise damaged.
WARNING:
Use of damaged electric cords can cause electric shock or fire.
Note: If an extension cord becomes hot to the touch, it is overloaded or damaged and must be replaced.
Northern Tool is NOT responsible for damage or injury resulting from customer use of inadequate extension cords.
15
Installation / Initial Set-Up
4. Select a Suitable Site
Before using the generator, you must select a suitable OUTDOOR location for installation and operation of your generator.
•
If you will be mounting the generator to a concrete slab, you must choose the location of the slab according to all the criteria listed below.
•
If the generator will be mounted to a trailer, you should follow all the criteria listed below to select a suitable location each time you use the generator.
WARNING:
You must choose a suitable site for operating your generator to avoid equipment damage and/or injury and possible death from carbon monoxide poisoning, electric shock, or fire.
Choose a site that meets all of the criteria specified.
Site/Location Criteria:
Dry, level surface The generator should be positioned on a dry, firm, level surface.
Ensure that the generator will sit during operation. Apply the tractor’s parking brake, and if trailer-mounted block the trailer’s wheels to prevent sliding and shifting.
Outdoors only – dangerous carbon monoxide exhaust
WARNING: Carbon monoxide poisoning hazard
The exhaust from your tractor contains carbon monoxide (CO), a poisonous gas that can kill. You cannot smell it, see it, or taste it.
Follow the directions below for choosing a location to operate your generator in order to avoid carbon monoxide poisoning.
The location you choose to operate the generator must be OUTDOORS and away from all air intakes :
•
Never run the generator or tractor inside any closed or semi-enclosed spaces (even if outdoors), including homes, garages, basements, sheds, or boxes. These spaces can trap poisonous gases, even if you run a fan or open windows.
•
Place the tractor so that the exhaust fumes will not be directed towards people or building air intakes.
•
Ensure that working, battery-operated or battery back-up carbon monoxide alarms are used in any dwelling/structure that is in close proximity to the running generator.
Adequate cooling ventilation
The generator needs adequate, unobstructed flow of air to allow for proper cooling of generator head.
•
Situate so there is adequate clearance around generator to allow for cooling airflow so that heat does not build up. Never block vent slots.
The closest object should be at 7 feet away from vents.
16
Installation / Initial Set-Up
•
Do not run the generator in close proximity to other heat-generating equipment, such as another generator. The combined heat that is generated may raise air temperature in the immediate area and there will not be adequate cooling ventilation.
•
Do not allow debris to accumulate and block airflow.
•
Do not operate with a tarp, blanket, or cover surrounding the generator.
Hot tractor exhaust clearance
The exhaust gas from your tractor is extremely hot and can cause combustible materials to catch on fire.
•
Position tractor at a safe distance from all nearby combustible materials and buildings/structures. Refer to your tractor manual to determine the safe clearance distance required for hot tractor exhaust in particular.
• Keep a fire extinguisher rated “ABC” nearby. Keep it properly charged and be familiar with its use.
No wet conditions Choose a location where the generator will NOT be exposed to rain, snow, or direct sunlight.
Exposure to water can cause electric shock.
You may operate the generator under an outdoor, canopy-like structure of heat-resistant material that is open on all sides. Make sure that all parts of canopy are:
• at least 7’ from generator
• at an adequate safe clearance from hot tractor exhaust.
Allow for adequate clearance above generator so that heat from generator does not build up.
Away from dust/dirt
Hearing protection
Do not use the generator in extremely dusty or dirty conditions.
Excessive dust and dirt can cause premature failure of the machine.
Generators can produce noise levels of up to 95 dB in close proximity, which can be dangerous to human hearing with prolonged exposure.
(This is in addition to the noise produced by the tractor.)
Hearing protection may be required for persons working within 15-20 feet of the running generator for an extended period of time.
17
Installation / Initial Set-Up
5. Mounting the generator
This generator must be securely mounted on a reinforced concrete slab or a PTO generator trailer before it is connected to your tractor’s PTO.* This will prevent the generator from flipping due to the rotational torque of the PTO.
The slab or trailer you use must be of adequate size and strength to withstand up to
101.7 pound-foot of operating torque without flipping or structural failure.
WARNING: Failure to properly mount and secure the generator may cause the unit to flip violently during use, which could cause severe injury to the operator or bystanders, or damage to surrounding objects.
Failure to properly mount the generator is not only unsafe, but will void the manufacturer’s warranty.
* Instructions for connecting generator to tractor PTO is provided later in this manual in the Operation section, “Step 3. Connecting to the Tractor”.
Mounting to a trailer
Mount to a trailer if you plan to use the generator as a portable source of power.
WARNING:
Never mount to a trailer that is not wide enough or strong enough to handle the operating torque. An inadequate trailer may flip or fail due to generator’s operating torque, potentially causing injury or death.
1. Use only a wide base trailer that is specifically designed for mounting a
PTO generator.
•
A PTO generator trailer is designed to be of adequate size and strength to withstand the generator’s operating torque without flipping or structural failure. o The trailer wheelbase must be wide enough to prevent flipping. o The trailer base must be constructed of thick enough steel to prevent metal fatigue from the constant vibration of the generator.
•
A trailer specifically designed for use with PTO generators rated up to
60,000 Watts is available from NorthStar -- Item #165959.
2. Mount the generator on the trailer so it is: o Balanced forward of the trailer axle to prevent the trailer from tipping backward. o Centered side-to-side between the trailer’s wheels to minimize the possibility the trailer will flip due to operating torque.
If using the NorthStar PTO trailer (Item #165959), specific mounting bolt patterns are illustrated in the trailer’s Owner’s Manual for various
NorthStar PTO generator models.
3. Bolt the generator to the trailer base using four, 5/8” grade 5 bolts. See the next section: “Mounting to a concrete slab”, Figure 6.
18
Mounting to a concrete slab
Installation / Initial Set-Up
If you will be using the generator in a permanent location, you may mount the generator to a reinforced concrete slab.
1. Choose a location for the slab that is as close to the load as possible (to minimize voltage drop) and which also meets all the criteria specified in the previous section, “
4. Select a Suitable Location
”.
2. The slab must: o Be of adequate size and weight to properly anchor the generator and resist flipping under operating torque. Typically the slab will need to be at least 2 feet x 2 feet x 4 inches thick. o Be reinforced with rebar in a direction perpendicular to the PTO shaft.
Rebar will strengthen the concrete to resist cracking and breaking as a result of operating torque and vibration. o Provide adequate elevation to ensure that the PTO driveline angle between the generator and tractor will not exceed 15 degrees. Note:
The smaller the angle, the longer the driveline will last.
For technical guidance on the design and construction of reinforced concrete slabs, refer to the American Concrete Institute (ACI) web site at www.concrete.org. The ACI has published several Technical Committee documents concerning the design and construction of concrete slabs.
WARNING:
Never attempt to mount generator to a slab that is not large enough or strong enough to withstand the operating torque. Slab failure could result in the generator flipping violently and possibly causing injury or death to those nearby.
3. Mount the plates to the concrete slab using four, grade 5, size 5/8” bolts.
Mounting Holes Mounting Holes
Figure 6
19
Installation / Initial Set-Up
6. Grounding the generator
Always ensure the generator is properly grounded to prevent electrical shock.
You must always ground the generator by the following method when using the generator as a portable electrical source:
1)
Drive a ¾” or 1” copper pipe or rod into the ground close to the generator. The pipe/rod must penetrate moist earth – the depth required will be dictated by local soil conditions.
Consult with an electrician.
2) Connect an approved ground clamp to the pipe.
3) Run an 8 gauge wire from the clamp to the generator grounding screw located on the rear of the generator head.
4) Do not connect the generator grounding post to a water pipe or a ground used by a radio system.
Grounding Post
Ground
8 Ga. Wire
Copper
Pipe/Rod
5) The generator must be grounded every time it is moved.
If a licensed electrician installs the generator with a connection to your building’s electrical circuit for use as a back-up power system, grounding may alternatively be completed through the building’s grounding system. Ask your electrician. If the generator is not grounded through your building’s electrical system, follow the procedure above.
WARNING:
Operating the generator when it is not properly grounded can result in electrical shock.
20
Operation
Once you have set up your generator for use, it is time to start your generator. The following are the procedures necessary for safe, successful operation of your generator.
Operation Procedures
1.
General Safety Rules for Operation
2.
Preparing for Operation
3.
Connecting to the Tractor
4.
Starting the Generator
5.
Connecting Electrical Loads
6.
Stopping
7.
Storage & Exercise of Generator
Each of these procedures is discussed in detail below:
1. General safety rules for operation
Before starting the generator, review the following general safety rules for operation:
WARNING :
Failure to follow safety rules may result in serious injury or death to the operator or bystanders.
•
Know proper use/how to stop.
Be thoroughly familiar with proper use of the equipment and all generator controls, output receptacles, and connections. Know how to stop the generator quickly if needed.
•
Instruct operators . The generator owner must instruct all operators in safe generator set-up and operation. Only trained adults should set up and operate the generator – Do not let children operate.
•
Intended use . Carefully read about and understand the intended use of this generator. Do not use for other purposes, as unforeseen hazards or equipment damage may result.
•
Under the influence . Never operate, or let anyone else operate, the generator while under the influence of alcohol, drugs, or medication.
•
Safety guards / controls . Do not operate the generator unless all safety covers, guards, and barriers are in place and in good working order, and all controls are properly adjusted for safe operation
•
Damaged . Do not operate the generator with damaged, missing, or broken parts.
•
Modifications . Do not modify the generator in any way. Modifications can create serious safety hazards and will also void the warranty.
•
Malfunction during operation. Immediately turn off the generator if any of the following conditions arise during operation: o Excessive change in tractor engine speed, slow or fast o Overheating in load connecting devices o Sparking or arcs from generator o Loss of electrical output o Receptacle damage o Excessive vibration o Flame or smoke o Abnormal noise
21
Operation (cont’d)
•
Adjusting / repairing . Always turn off generator and remove PTO driveline before working on the generator.
Always discharge the capacitor before working on the generator head to prevent electrical shock. (See Maintenance & Repair section of this manual for instructions on how to do this.)
•
Carbon monoxide poisoning . The running tractor engine gives off carbon monoxide, a poisonous gas that can kill you. You CANNOT smell it, see it, or taste it. Follow all instructions for site selection and positioning the tractor and generator, and avoid inhaling the exhaust. If you start to feel sick, dizzy, or weak, shut off the tractor and get to fresh air RIGHT AWAY. See a doctor. You may have carbon monoxide poisoning.
•
Electrical cords.
Use only UL-listed, outdoor-rated, three prong extension cords of the proper size. All extension and appliance cords must be in good condition and not worn, bare, frayed, or otherwise damaged. Use of inadequate or damaged electric cords can cause electric shock or fire.
•
GFCI extension cords.
Always use ground fault circuit interrupter (GFCI)-equipped extension cords in damp or highly electrical conductive areas and on construction jobsites to prevent electrical shock.
•
•
Avoid contact . Avoid contact with bare wires, terminals, connections, etc. while the unit is running.
Wet conditions.
Do not operate the generator or handle any electrical equipment while standing in water, while barefoot, while hands are wet or while in the rain or snow. Electric shock may result.
•
Electric shock accident.
If an electric shock accident occurs, immediately shut down the source of electrical power. If this is not possible, attempt to free the victim from the live conductor. Avoid direct contact with victim. Use a nonconducting implement, such as a dry rope or board, to free the victim from the live conductor. Apply first aid and get immediate medical help.
•
Smoking/sparks . Never smoke near the running generator, and never operate near sources of sparks or flames.
•
Hot parts. Parts of the generator are extremely hot during and after operation and can burn you. Never touch hot gearbox, and do not touch any other part of the generator unless you have first determined if it is hot. Wait a sufficient time for parts to cool before touching any part of the generator.
•
Moving parts . Keep hands, feet, and apparel away from PTO connections, drive shaft, belts, fans, and other moving parts. Never attempt to remove drive shaft or any guard or shield while the unit is operating.
Mount generator
2. Preparing for Operation
Make sure the generator is mounted in accordance with instructions given in “Installation / Initial Set-up section, Step 5: Mounting the Generator” of this manual.
WARNING:
Always ensure generator is properly mounted to prevent it from flipping during use, which could cause equipment damage and injury to nearby persons.
Position generator
Position tractor and generator in accordance with the instructions given in
“Installation / Initial Set-up section, Step 4: Select a Suitable Site” of this manual.
Operate outside only, on dry, level ground with adequate clearance and ventilation. Apply parking brake, and block trailer wheels if generator is trailermounted.
WARNING: Carbon monoxide poisoning hazard
The tractor engine gives off carbon monoxide exhaust, a poisonous gas that can kill. You CANNOT smell it, see it, or taste it. ONLY run
22
Operation (cont’d)
generator OUTDOORS and away from air intakes. NEVER run tractor and generator inside any enclosed or semi-enclosed spaces, including homes, garages, basements, sheds, boxes, pick-up truck beds, RVs, or boats. These spaces can trap poisonous gases, EVEN if you run a fan or open windows .
Ground generator
Make sure the generator is grounded in accordance with instructions given in “Installation / Initial Set-up section, Step 6: Grounding the Generator” of this manual.
WARNING: Electric shock hazard
Always ensure generator is properly grounded to prevent electrical shock.
IMPORTANT: The generator must be grounded every time it is moved.
Make sure that any regular maintenance has been performed as prescribed in this manual in the “Maintenance & Repair” section.
Perform regular maintenance
Check/add oil Check the gear box oil level and add oil as needed.
1.
First time use only: If you have not already done so, remove the temporary shipping plug from the oil port and replace with the metal breather/oil fill plug that is in the manual bag.
2.
Check oil level using the sight mounted on the gearbox. When oil level is even with the red dot, the oil level is correct.
3.
If oil needs to be added, remove the filler/breather plug at the top of the gearbox. Use SAE 90W gear oil to refill so that oil level is even with the red dot. Do not overfill. Overfilling can cause the oil to overheat and cause damage to generator.
WARNING: Burn hazard
Never open oil port while generator is running. Hot oil can spray over face and body.
˙
IMPORTANT:
Under long, continuous-run operating conditions, be prepared to:
•
Check gear oil level daily.
• Change gear oil monthly (see instructions in “Maintenance & Repair” section of this manual).
Personal
Protection
1) Hearing can be damaged from prolonged, close-range exposure to the type of noise produced by this generator. The use of ear plugs or other hearing protection device is recommended for persons working within 15-20 feet of the running generator for an extended period of time.
2) Loose or dangling apparel and long hair can become quickly entangled in moving/rotating parts. Metal jewelry can conduct electricity. Never wear jewelry or loose-fitting clothing such as neckties, scarves, or long-sleeved or untucked shirts when starting or adjusting the generator . Tie back and secure hair close to the head.
23
Operation (cont’d)
3. Connecting to the Tractor
Follow the instructions in this section to connect the generator to the tractor’s PTO via a driveline shaft (purchased separately).
Acquire PTO driveline shaft
Acquire a synchronized 1-3/8”, 6 spline PTO driveline rated at 24 HP minimum.
A suitable PTO driveline, available from Northern Tool ( Item #165936 ), includes the following advanced safety features:
•
A telescoping shaft o to provide flexible accommodation of mounting distance between tractor and generator o to allow for dynamic compression and stretching while turning or driving a trailer-mounted generator over uneven ground.
•
Protrusion-free end yokes with slide collars that lock into place.
•
An internal cable stop to prevent separation of driveline halves.
•
A non-rotating tubular shaft guard with anchoring chain, plus shield cones that cover the rotating yokes with a 2” overlap
•
Grease zerks to allow for proper lubrication of driveline joints.
It is strongly recommended that any driveline utilized have these safety features.
Attach PTO driveline shaft
Connect the PTO driveline shaft to the tractor and generator:
1.
Align the tractor and generator to minimize the driveline angle in both the horizontal and vertical planes; it should be as near to a direct line in all directions as possible. The angle should never exceed 15° in any direction.
Note: Proper alignment will increase the life of the power takeoff shaft, reduce wear on the bearings of the PTO and generator, and reduce vibration.
Max. 15
Top View
Driveline
Side View
Max. 15
24
Operation (cont’d)
2.
Ensure that the tractor PTO is disengaged and the tractor is turned OFF.
3.
Connect one end of the PTO driveline shaft to the generator’s input shaft.
4.
Connect the other end to the tractor PTO stub.
WARNING :
Make sure PTO driveline shaft is securely locked at both ends. Unlocked
PTO shafts can whip or become dangerously airborne.
Secure driveline guard
& check shields
1.
A driveline GUARD must ALWAYS be used with the driveline shaft.
Secure the driveline guard according to manufacturer’s instructions.
2.
Make sure the tractor and generator shields are in place at both ends of the driveline shaft: o On the tractor where the driveline connects to the PTO stub o On the generator where the driveline connects to the input shaft.
WARNING :
Never operate the generator without proper PTO guarding, including a freely rotating shaft guard as well as tractor and generator shields at both ends. Clothing or hair can become rapidly entangled in unguarded rotating PTO shaft or connections, resulting in serious injury or death.
4. Starting the Generator
To start the generator:
1.
Start the tractor with the PTO control in the “disengaged” position.
2.
While seated on the tractor and the engine at idle, engage the PTO.
3.
Slowly increase the throttle until the needle in the generator voltmeter is at or above the black line in the green area.
Red Green
25
Operation (cont’d)
5. Connecting Loads
You will want to be careful when connecting loads so as not to overload the generator, especially if you are powering devices with motors that require a higher starting power load.
Instructions are provided below for connecting loads when you are using the generator: o As a portable power source o Connected to a building as a back-up power source
WARNING :
Do not overload generator. Make sure that combined starting and running loads do not exceed rated capacity of generator. Overloading the generator can cause damage to the generator and attached electrical devices, and may result in fire.
Using as a
Portable Power
Source
Connect electrical loads one at a time according to the following instructions:
1.
Allow engine to reach operating speed by allowing it to warm up for approximately 5 minutes before connecting electrical devices.
2.
After engine is warmed up, begin connecting the loads one at a time.
WARNING : Stay clear of the rotating PTO driveline!
Start with those that require the highest wattage first. The recommended sequence is as follows: a.
Connect items with motors such as refrigerators, freezers, air conditioners, or small hand tools, one at a time. Let each motor stabilize before connecting the next device. b.
Connect any lights you are planning on powering. c.
Connect voltage sensitive equipment such as electronics via surge protectors. Plug devices such as TV’s, computers, and microwaves into a UL listed voltage surge protector, then plug the surge protector into the generator.
3.
After connecting each load, return to the driver’s seat. Readjust the throttle until the needle on the generator’s voltmeter is close to the black line in the green area. o If the needle will not rise to the green area no matter what the engine speed, the generator is either overloaded or there is a problem. o Shut off the tractor and refer to the Troubleshooting guide at the end of this manual for assistance with possible problems.
Also check your tractor’s PTO rating to make sure it is capable of producing a minimum of 24 HP at 540 RPM. This is not necessarily equivalent to the HP rating for the tractor itself.
26
Using as a
Back-up Power
Source for a
Building
Operation (cont’d)
WARNING :
The generator must be run at the correct speed in order to produce the proper electrical voltage and frequency. Failure to do so could result in damage to equipment powered by the generator and possible injury to the individual.
Note: All engines have a tendency to slow down when a load is applied.
When electrical loads are connected to the generator, the engine is more heavily loaded and as a result the speed drops slightly.
This slight decrease in speed, together with the voltage drop within the generator itself, results in a slightly lower voltage when the generator is loaded to its full capacity than when it is running with no load. Additionally, there may be small brief surges and drops in voltage as motors connected to the generator cycle on or off.
The slight variation in voltage, as long as the needle remains in the green area, has no appreciable effect in the operation of motors, lights, and most appliances.
Each transfer switch installation will be unique. Proper instructions for how to safely bring the generator online with the building’s electrical system should be provided by the installing electrician, who should also provide personal instruction to the owner/operator.
Failure to follow the proper procedure as provided by the electrician could expose persons to the hazards noted above.
Note: After you have brought the generator online with the transfer switch, you will need to adjust the tractor’s throttle speed to maintain correct output voltage under load. Adjust the throttle until the needle on the generator’s voltmeter is close to the black line in the green area. (See more detail about maintaining proper voltage in the instructions given above for using the generator as a portable power source.)
27
Operation (cont’d)
6. Stopping
Stop the generator using the following steps:
1.
Disconnect all loads to generator. (Never reduce throttle with electrical loads connected.
Damage to generator and loads will occur.)
2.
After all loads are disconnected, slowly reduce PTO speed to a minimum and then disengage
PTO.
3.
Shut OFF the tractor engine.
4.
Remove the PTO driveline shaft from generator and tractor.
7. Storage & Exercise
When you are finished using the generator, you must: o Disconnect all loads and PTO driveline o Store the generator properly o Plan on exercising the engine regularly
Detailed instructions are provided below.
Disconnect loads &
PTO
When you are finished using the generator:
1.
Make sure all loads are disconnected from generator’s outlets.
2.
Make sure the generator is disconnected from the PTO.
Store in appropriate location
1.
Let generator cool for at least five minutes before storing.
Hot equipment can be a fire hazard near combustible materials.
2.
Store the generator in a location that is: o Clean and dry. It is important to keep the generator windings free of moisture. o Away from extreme high or low temperatures.
Exercise generator every 4 weeks
The generator should be exercised regularly.
At least every four weeks, start the generator and let it run for 10 to 15 minutes.
Monthly exercising of the generator will: o Dry out any moisture that has accumulated in the windings. If left, this moisture can cause corrosion in the winding. o Ensure that the unit is operating properly should it be needed in an emergency.
Perform regular maintenance
Perform periodic maintenance as directed in this manual to keep the generator in safe working condition.
28
Maintenance & Repair
Inspect and maintain your generator as specified below in order to keep it in safe and optimal working order. Follow all safety rules and recommended maintenance steps.
WARNING
ALWAYS shut off the engine, remove PTO driveline and discharge the capacitor before cleaning, adjusting, or servicing the generator. Make sure all guards and shields are replaced before using.
Note: The generator head is brushless and maintenance free. The bearing is a heavy-duty sealed ball bearing which requires no maintenance or lubrication.
Maintenance & Repair
Follow safety rules Read and follow these safety rules whenever you will be servicing the generator:
•
Turn off generator.
Always stop tractor engine and remove PTO driveline before working on the engine or generator to prevent accidental starting.
•
Discharge capacitor. When the generator is shut down, the capacitor may maintain a charge. Always discharge the capacitor before working on the generator head to prevent electrical shock. Discharge using a screwdriver with an insulated handle. While wearing safety glasses, touch opposite terminals of the capacitor together with the tip of the screwdriver. If there is stored charge in the capacitor, a spark will be generated thereby discharging the capacitor.
•
Replace guards.
Make sure all guards and shields are replaced after servicing the generator.
•
Repair.
Major service, including the installation or replacement of parts, should be performed only by a qualified electrical service technician. Obtain factory approved parts from Northern Tool Product Support at 1-800-270-0810.
•
Replacement parts . If a part needs replacement, only use factory approved repair parts. Replacement parts that do not meet specifications may result in a safety hazard or poor operation of the generator and will void the warranty.
Maintain gear oil Check the gear oil level before each use and add oil as needed. Change gear oil every year.
WARNING: Burn hazard
Never open oil port while generator is running. Hot oil can spray over face and body.
1. Check/add oil before each use: a.
Check oil level using the sight mounted on the gear box. When oil level is even with the red dot, the oil level is correct. b.
If oil needs to be added, remove the filler/breather plug at the top of the gearbox. Use SAE 90W gear oil to refill so that oil level is even with the red dot. Do not overfill. Overfilling can cause the oil to overheat and cause damage to generator.
29
Maintenance & Repair (cont’d)
2. Change oil every year: a.
Drain oil from gearbox (drain plug is underneath gearbox). b.
Replace drain plug. c.
Refill with SAE 90W gear oil. Refill so that oil level is even with the red dot.
IMPORTANT:
Under long, continuous-run operating conditions, be prepared to add and change oil more frequently:
•
Check gear oil level daily.
•
Change gear oil monthly.
Check receptacles Check receptacles before each use to make sure they are not cracked or broken.
If a receptacle is cracked or otherwise damaged, do not use until replaced with an authorized factory part. Using cracked or damaged receptacles can be both dangerous to the operator and destructive to the equipment.
Keep generator clean
Keep generator clean.
If dust or debris accumulates on the generator, clean the generator with a damp cloth or soft bristle brush. Do not allow air intakes to become blocked.
Note: Do not spray generator with a garden hose or pressure washer.
Water may enter the generator and cause damage to the rotor, stator, or internal windings.
IMPORTANT:
If a part needs replacement, only use parts that meet the manufacturer’s specifications. Replacement parts that do not meet specifications may result in a safety hazard or poor operation of the generator.
Contact NorthStar Product Support at 1-800-270-0810 for any questions, problems, or parts orders.
30
Troubleshooting
Problem
Voltage too low
Circuit breaker trips a) Defective load connected to generator b) Defective receptacle c) Generator is overloaded d) Defective circuit breaker
Voltage too high a) Tractor throttle set too high
Generator overheating a) Generator is overloaded
No output voltage
Excessive gearbox noise
TROUBLESHOOTING
Possible Causes
a) Tractor throttle set too low b) Generator is overloaded a) Defective load connected to generator b) Broken or loose wire c) Defective receptacle d) Defective stator e) Defective rotor f) Defective capacitor g) Defective circuit breaker h) Tractor throttle set too low i) PTO not engaged j) Gearbox malfunctioning k) Circuit breaker tripped. a) Defective bearing b) Defective gear c) No or low gear oil d) PTO driveline is operating at an angle of greater than 15
e) Unsynchronized PTO driveline
Possible Remedies
a) Increase tractor RPMs. b) Reduce the load (See Power Load Planning &
Mgt. section of this manual). a) Disconnect load. b) Replace receptacle – Contact Product Support for the nearest service center. c) Reduce the load (See Power Load Planning &
Mgt. section of this manual). d) Contact Product Support for nearest service center. a) Decrease tractor RPMs. a) Reduce the load (See Power Load Planning &
Mgt. section of this manual). a) Disconnect load. b) Replace or tighten wire – Contact Product for the nearest service center. c) Replace receptacle – Contact Product Support for the nearest service center. d) Contact Product Support for the nearest service center. e) Contact Product Support for the nearest service center. f) Contact Product Support for the nearest service center. g) Contact Product Support for the nearest service center. h) Increase tractor RPMs. i) Engage PTO. j) Contact Product Support for the nearest service center. k) Reset circuit breaker and reduce loads connected to the generator. a) Contact Product Support for the nearest service center. b) Contact Product Support for the nearest service center. c) Fill gearbox to middle of oil level sight glass. d) Reposition the tractor or generator so the angle is reduced to less than 15
both vertically and horizontally. e) Disassemble PTO driveline and reassemble with CV joints synchronized.
31
Summary of Important Safety Information for Operation
This section provides a summary of the various safety procedures and measures that have been presented throughout the manual. Keep this summary handy and refer to it to refresh your memory about how to safely use your generator.
WARNING
Carefully read and make sure you understand the following safety information before using the generator.
Improper use or maintenance of the generator can result in serious injury or death from
carbon monoxide poisoning, electric shock, entanglement, fire, or burns. In addition,
PTO shaft and generator can become airborne and cause severe injury if improperly secured.
General
•
Read manual.
Read this Owner’s Manual and the engine Owner’s Manual completely before attempting to set-up and use the generator . Serious injury or death can result if safety instructions are not followed.
•
Instruct operators . The generator owner must instruct all operators in safe generator set-up and operation.
Do not allow anyone to operate the generator who has not read the Owner’s Manual and been instructed on its safe use.
•
Adults only.
Only trained adults should set up and operate the generator. Do not let children operate.
•
Under the influence . Never operate, or let anyone else operate, the generator while under the influence of alcohol, drugs, or medication.
•
Intended use . Carefully read about and understand the intended use of this generator. Do not use for other purposes, as unforeseen hazards or equipment damage may result.
Prohibition Against Modifications
•
Modifications prohibited.
Never modify or alter the generator in any way. Modifications can create serious safety hazards and will also void the warranty.
•
Guards . Do not operate generator unless all guards and cover shields, which prevent access to moving parts and pinch points, are in place. Failure to guard the power transmission mechanisms may result in serious injury or death.
Safety – Installation & Set-up
•
Mount generator.
Failure to properly mount and secure the generator may cause the unit to flip violently during use, which could cause severe injury to the operator or bystanders, or damage to surrounding objects.
•
The generator must be securely mounted to either a reinforced concrete slab or a trailer.
•
Slab or trailer must be of adequate size and strength to withstand operating torque without flipping or structural failure.
• See the “Installation / Initial Set-Up” section of this Owner’s Manual for mounting requirements and instructions.
•
Dry, level surface . Situate generator on a dry, firm, level surface. Ensure generator sits level and will not slide or shift during operation. Apply parking brake, and block trailer wheels if generator is trailer-mounted.
•
Operate OUTSIDE only – dangerous carbon monoxide exhaust ! The running tractor gives off carbon monoxide exhaust, a poisonous gas that can kill. You CANNOT smell it, see it, or taste it. ONLY run generator OUTDOORS and away from building air intakes. NEVER run generator inside homes, garages, sheds, or other semi-enclosed spaces. These spaces can trap poisonous gases, EVEN if you run a fan or open windows
•
Cooling ventilation . The generator needs adequate, unobstructed flow of air to allow for proper cooling of engine and generator head so it does not overheat and possibly cause fire. Situate so there is adequate clearance around generator to allow for cooling airflow. Do not allow debris to accumulate and block airflow.
Keep all objects at least 7 feet away from vent slots.
•
Grounding . Always ensure generator is properly grounded to prevent electrical shock. This generator is equipped with a grounding post. Always complete the grounding path from the generator to a copper pipe/rod driven into moist earth to a sufficient depth. Check with an electrician for local grounding requirements. If a licensed electrician installs the generator with a connection to your building’s electrical circuit for use as a standby power system, grounding will be complete through the building’s grounding system.
32
Summary of Important Safety Information for Operation (cont’d)
•
Isolate connection to building’s electrical circuit . Never plug the generator directly into a wall outlet.
ANY connection to a building’s electrical system MUST ISOLATE THE GENERATOR FROM UTILITY
POWER via an UL-approved transfer switch installed by a licensed electrician in compliance with all applicable local building and electrical codes. If the generator is not isolated from the utility power system by such means, generator output will back feed into the utility power grid. This may result in injury or death to utility power workers or others who contact the lines during a power outage. It may also cause the generator to explode or cause fires when utility power is restored.
•
Wet conditions . Water conducts electricity. Do not operate generator where it is wet. Operate on a dry surface under an open, canopy-like structure.
•
CO alarms . Ensure that working, battery-operated or battery back-up carbon monoxide alarms are used in any dwelling/structure that is in close proximity to the running generator.
•
Hot tractor exhaust . Tractor exhaust can be extremely hot and cause fire. Refer to your tractor manual to determine safe clearance distance required between hot tractor exhaust and nearby combustible objects.
•
Fire extinguisher
. Keep a fire extinguisher rated “ABC” by the National Fire Protection Association nearby.
Keep it properly charged and be familiar with its use.
Safety – Before Use
Know how to operate
•
Review safety rules
. Before each use of this generator, review the “Rules for Safe Operation.” Failure to follow these rules may result in serious injury or death.
•
Know how to operate. Be thoroughly familiar with all controls and with the proper use of the equipment.
Know how to stop the generator quickly if needed.
Personal protective equipment
•
Hearing protection . The use of earplugs or other hearing protection device is recommended for those in close proximity to the generator while it is operating.
•
No loose / dangling apparel . Loose or dangling apparel and long hair can become entangled in moving/rotating parts. Metal jewelry can conduct electricity. Never wear jewelry or loose-fitting clothing such as neckties, scarves, or long-sleeved or untucked shirts when operating the generator. Tie back hair and secure close to head.
Safety – During Use
•
Safety equipment / controls . Always operate the generator with all safety covers, guards, and barriers in place and in good working order, and all controls properly adjusted for safe operation.
•
Know how to stop . Be thoroughly familiar with proper use of the equipment and all generator controls, output receptacles, and connections. Know how to stop the generator quickly if needed.
•
Damaged . Do not operate the generator with damaged, missing, or broken parts.
•
Carbon monoxide exhaust . The running tractor engine gives off carbon monoxide, a poisonous gas that can kill you. You CANNOT smell it, see it, or taste it. If you start to feel sick, dizzy, or weak while using the generator, shut off the tractor and get to fresh air RIGHT AWAY. See a doctor. You may have carbon
•
Smoking/sparks . Never smoke near the running generator, and never operate near sources of sparks or flames.
•
PTO shaft secured.
Make sure PTO driveline shaft is securely locked at both ends. An unlocked PTO shaft can whip or become dangerously airborne.
•
PTO guards.
Never operate the generator without proper PTO guarding, including a freely rotating shaft guard as well as tractor and generator shields at each end. Clothing or hair can become rapidly entangled in unguarded rotating PTO shaft or connections, resulting in serious injury or death.
•
Driveline angle.
Never operate the generator continuously when the PTO driveline shaft is at an angle greater than 15° either horizontally or vertically.
•
Check output voltage . Check output voltage to ensure the generator is working properly before connecting loads to the generator. Failure to do so could result in damage to equipment powered by the generator and possible injury to the individual. Do not adjust output speed of engine to change voltage. If voltage is not within specified range, have generator repaired by factory-authorized personnel.
•
Stabilize before connecting loads. Start generator and let engine stabilize before connecting electrical loads.
•
Do not overload . Do not overload the generator. Make sure that combined starting and running loads do not exceed rated capacity of generator or damage will result.
33
Summary of Important Safety Information for Operation (cont’d)
•
Protect sensitive electronics . Some electronic equipment, such as computers and audio/video equipment, can be damaged by small fluctuations in the flow of power. Use a surge suppressor for any voltage-sensitive electronic equipment you will be powering with the generator.
•
Electrical cords.
Use only UL-listed, outdoor-rated, three prong extension cords of the proper size. All extension and appliance cords must be in good condition and not worn, bare, frayed, or otherwise damaged.
Use of inadequate or damaged electric cords can cause electric shock or fire.
•
GFCI extension cords.
Always use ground fault circuit interrupter (GFCI)-equipped extension cords to prevent electrical shock in damp or highly electrical conductive areas and on construction jobsites.
•
Wet conditions.
Do not operate the generator or handle any electrical equipment while standing in water, while barefoot, while hands are wet or while in the rain or snow. Electric shock may result.
•
Avoid contact . Avoid contact with bare wires, terminals, connections, etc. while the unit is running.
•
Electric shock accident.
If an electric shock accident occurs, immediately shut down the source of electrical power. If this is not possible, attempt to free the victim from the live conductor. Avoid direct contact with victim. Use a nonconducting implement, such as a dry rope or board, to free the victim from the live conductor. Apply first aid and get immediate medical help.
•
Hot parts. Parts of the generator are extremely hot during and after operation and can burn you. Never touch hot gearbox, and do not touch any other part of the generator unless you have first determined if it is hot. Wait a sufficient time for parts to cool before touching any part of the generator.
•
Moving parts . Keep hands, feet, and apparel away from PTO connections, drive shaft, belts, fans, and other moving parts. Never attempt to remove drive shaft or any guard or shield while the unit is operating.
•
Malfunction during operation. Immediately turn off the generator if any of the following conditions arise during operation: o Excessive change in tractor engine speed, slow or fast o
Overheating in load connecting devices o
Sparking or arcs from generator o Loss of electrical output o Receptacle damage o Excessive vibration o Flame or smoke o Abnormal noise
•
Adjusting / repairing . Always turn off generator and remove PTO driveline before working on or cleaning the generator.
Safety – After use
•
Driveline removed.
Always stop tractor engine and remove driveline after use.
•
Cool before storing. Let generator cool for at least five minutes before storing. Hot equipment can be a fire hazard near combustible materials.
•
Storage location.
Store the generator in a dry location.
•
Exercise regularly.
Exercise generator every four weeks to dry out moisture that accumulates in the windings. If generator cannot be exercised on a regular basis, prepare generator for long-term storage.
•
Periodic maintenance.
Perform periodic maintenance as directed in this manual to keep the generator in safe working condition.
Safety - Inspection/Maintenance
Inspect and maintain your generator on a regular basis and repair as needed to keep it in safe working condition:
•
Generator off & driveline detached . Always stop tractor engine and remove PTO driveline before working on or cleaning the generator.
•
Discharge capacitor. When the generator is shut down, the capacitor may maintain a charge. Always discharge the capacitor before working on the generator head to prevent electrical shock.
•
Clear debris/deposits.
Keep generator head and moving parts clean. This will ensure the generator is in safe working condition.
•
Replace guards / shields.
Make sure all guards and shields are replaced after servicing the generator.
•
Replacement parts.
If a part needs replacement, only use parts that meet the manufacturer’s specifications.
Replacement parts that do not meet specifications may result in a safety hazard or poor operation of the generator and will void the warranty
34
PTO Generator Exploded View Rev – G.5
Item Part# Description
22
23
24
25
26
8
9
10
11
12
13
14
4
5
6
7
1
2
3
39138
38541
31727
779781 Warning decal
82070 1/420 x .5” Serrated flange bolt
82005
306422
39137
82004
39074
Control box top
NorthStar decal
Voltmeter
#8-32 Keps nut
120/240V, 30A receptacle
Control box
#8-32 Button head cap screw
Control panel decal
305587 Isolation mount
82158 M5-.8 x 14mm Pan Phillips screw
82243 M5-.8 Hex nut
82161 Grounding screw
15
17
38280 Bracket securing stud
38271 End cover plug
18 788185 End cover
19 MA38279 Capacitor
20 82091 5/1618 x 1” Hex head cap screw
21 39140 Base
82019 5/16-18 Serrated flange nut
82049 M10 Rib washer
82241 M10-1.5 x 20mm screw
38278 Non drive end bracket
779406 CO danger decal
4
1
1
1
1
1
5
16
8
1
1
1
1
1
1
8
8
1
1
8
1
4
2
2
1
41
44
45
46
47
48
49
50
51
52
34
35
36
37
38
39
40
27
28
29
30
31
32
33
Qty Item Part# Description
38276 Bearing
780143 Rotor securing stud
307479 Diode
307481 Varistor
780229 Rotor
780142 Stator
38270 Enclosing band
781479 Drive end bracket
779557 Fan
82102 3/816 x .75” Serrated flange bolt
779556 Fan bolt
780228 Mount plate
38890 Gearbox
82014 5/1618 x .5” Serrated flange bolt
780825 Control box mount plate
306459 Ground wire
31736 120V, 20A Duplex receptacle
30643 Circuit breaker, 125V-20A
777130 Circuit breaker mounting clip
31005 Thermal breaker, 125/250V-30A
39053 Implement shield
779770 PTO Warning decal
82201 M10 Flat washer
82137 M10-1.5 x 16mm Hex head cap screw
35
Qty
4
1
1
1
1
1
2
2
4
4
2
1
1
4
1
1
4
2
1
1
1
1
1
2
Wiring Diagram Rev – G.5
Ref #
1
2
3
4
5
6
7
B14
B15
B16
B44
B45
B46
Part # Description
31736 120V 20A Duplex Receptacle (NEMA 5-20R)
30643 20A Circuit Breaker
31005 Circuit Breaker, 30A
777130 Mounting Clip
306422 L14-30R Receptacle
39061 Lead Wire (V-)
39056 Wire Harness (B1, B4, G, G1, G2, W2, W3, W4, W5, W6)
39059 Lead Wire Assembly (B14, V+)
305608 Lead Wire Assembly (B15)
307500 Lead Wire Assembly (B16)
39060 Lead Wire Assembly (B44)
305609 Lead Wire Assembly (B45)
307501 Lead Wire Assembly (B46)
Qty
1
2
1
4
1
1
1
1
1
1
1
1
1
36
PTO Gearbox Exploded View Rev – G.5
Item Part# Description
1 BP2009168109 Housing
2 N/A Order Gear Box
3 N/A
#38890
Order Gear Box
#38890
4 BP2009169246 Flange
Qty Item
1
1
1
14
15
16
Part#
Note: Gearbox exploded view is shown upside-down when compared to its orientation on the
BP8575378000 Pin, 8x20mm
BP8600103000 Cap
BP8600142000
5 N/A Order Gear Box
#38890
6 BP2009109109 Housing
7 BP8025302000 Circlip
1 17 BP8600144000 Oil plug, 3/8”
1 18 BP8600146000
Drain plug, 3/8”
1 19 BP8600170000 Cap
1 20 BP8600580000 Cap
8 BP8050218000 Oil seal,
25x52x10mm
9 BP8050360000 Oil seal,
35x52x10mm
1 21 BP8625178000 Sight glass
1 22 BP8675186080 Screw, M8 x
20mm
10 BP8125300001 Key, 10x8x25mm 1 23 BP8675191000 Screw, M8 x
40mm
11 BP8200196000 Bearing 3 24 BP8675216000 Screw, M8 x
110mm
12 BP8200216000 Bearing
13 BP8225247000 Nut, M8
1 25 BP2070005682 Sleeve
8
Qty
2
3
Breather plug, 3/8” 1
1
1
1
2
1
2
6
2
2
37
This page has intentionally been left blank.
38
Limited Warranty
Dear Valued Customer:
The NorthStar Product you just purchased is built with the finest material and craftsmanship. Use this product properly and enjoy the benefits from its high performance. By purchasing a NorthStar product, you show a desire for quality and durability. Like all mechanical equipment this unit requires a due amount of care. Treat this unit like the high quality piece of machinery it is. Neglect and improper handling may impair its performance. Please thoroughly read the instructions and understand the operation before using your product. Always contact NorthStar Product Support at 1-800-
270-0810 prior to having any service or warranty work performed, as some services performed by parties other than
NorthStar approved service centers may void this warranty. This warranty is in lieu of any other warranty expressed or implied and NorthStar assumes no other responsibility or liability outside that expressed within this warranty.
Limited Warranty
NorthStar shall warranty any piece of equipment manufactured, or parts of equipment manufactured, to be free from defects in material or workmanship for a period of:
NorthStar Warranty
Item # Consumer Warranty Period Commercial Warranty Period
165951 2 years from date of purchase by user 2 years from date of purchase by user
“Consumer use” means personal residential household and/or recreational use by a consumer. “Commercial use” means all other uses, including use for commercial, income producing, primary power, off grid power, or rental purposes or when purchased by a business.
This warranty applies to the original purchaser of the equipment (verification of purchase, in the form of a receipt, is the responsibility of the buyer), is non-transferable, and covers parts and labor. Parts will be replaced or repaired at no charge, except when the equipment has failed due to lack of proper maintenance. If a part is no longer available, the part may be replaced with a similar part of equal function. Any misuse, abuse, alteration or improper installation or operations will void warranty. Determining whether a part is to be replaced or repaired is the sole decision of NorthStar.
NorthStar will not provide for replacement of complete products due to defective parts. Any costs incurred due to replacement or repair of items outside of a NorthStar approved facility is the responsibility of the buyer and not covered under warranty. Transportation costs to and from service center is the responsibility of the customer.
This warranty specifically excludes the following; failure of parts due to damage caused by accident, fire, flood, windstorm, acts of God, applications not approved by NorthStar in writing, corrosion caused by chemicals, use of replacement parts which do not conform to manufacturer’s specifications, damage to accessory parts such as starting batteries , damage related to rodent and/or insect infestation and damage caused by vandalism. Additional exclusions: loss of running time, inconvenience, loss of income, or loss of use, including any implied warranty of merchantability of fitness for a specific use. Also, Outdoor Power Equipment needs periodic parts and service to perform well, and this warranty does not cover instances when normal use has exhausted the life of a component or the engine.
This warranty does not cover any personal injury or damage to surrounding property caused by failure of any part.
Repair or replacement of parts does not extend the warranty period.
Please fill in the following information and have it on hand when you call in on a warranty claim.
Customer Number: ______________________________________________________________
Date of Purchase: _______________________________________________________________
NorthStar Serial Number: _________________________________________________________
Item Number: __________________________________________________________________
39
WARNING : This product can expose you to chemicals including gasoline engine exhaust, which is known to the State of California to cause cancer, and carbon monoxide, which is known to the State of
California to cause birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov
.
Manufactured by
Northern Tool + Equipment Co.,
2800 SouthCross Drive West
P.O. Box 1499 Burnsville, MN 55337-0499
40
advertisement
Related manuals
advertisement