Lindy IPower Switch Classic 8 (Power Management over IP) Manual

Add to My manuals
4 Pages

advertisement

Lindy IPower Switch Classic 8 (Power Management over IP) Manual | Manualzz
English Manual
1. Introduction
The LINDY IPower Switch Classic is an Internet ready device designed and is equipped with an
intelligent current-meter (True RMS) that will indicate the total power consumption of a power
strip. The LINDY IPower Switch Classic offers an easy set up and user-friendly communication
software. This software provides assistance to the network administrator to remotely monitor the
multiple PDU power consumption to realize the total current power consumption.
IPower Switch Classic 8
IPower Switch Classic 16
User Manual
English
Features
• Built-in web server, supports real time monitoring for the current
consumption of the power strip.
• Build-in true RMS current meter.
• Easy setup, the display shows the current IP address of the unit directly.
• Provides audio alarm when the power consumption exceeds the value setting
for overload warning.
• Sends email and SMNP traps when the power consumption exceeds the value
for overload warning.
• Software utility included, which monitors a number of IPower Switches Classic
simultaneously
• Supports the SNMP protocol and provides an MIB for the unit.
• Provides power protection by a circuit breaker.
• Slim size - suitable for a variety of rack environments.
• Real time control for each outlet.
• LED status indicator for every outlet.
• Power on switching sequence adjustable.
2. Package Content
The standard Amazing PDU package contains a Power Distribution Unit with supporting
hardware and software. The components of the package are:
• Power Distribution Unit.
• Rack mount Brackets.
• CD-ROM, containing:
User Manual.
Amazing PDU Software.
MIB: Management Information Base for Network. (AmazingMIB.mib)
Adobe Acrobat Reader.
LINDY No. 32657, 32658
For Home and Office Use
Tested to Comply with
FCC Standards
© LINDY ELECTRONICS LIMITED
www.LINDY.com
&
LINDY-ELEKTRONIK GMBH
-
FIRST EDITION (Jun 2009)
2
English Manual
English Manual
3. Function
4. Installation
This section will instruct you to quickly install the Amazing PDU.
Interface:
Function
Ethernet
Audible Alarm
Function Button
Meter
LED Indicator
Output LED
Description
Network connection for the built-in web server
1. Warning: 1 beep in 1 second
2. Overload: 3 beeps in 1 second
Note: the overload alarm will not stop until the current falls back to
0.5 Amps below the setting value for overload or warning.
1. Press and release this button to turn off the warning audible alarm.
The overload alarm can’t be stopped by this button.
2. Pressing the button and releasing it after two beeps will show up
the unit’s IP address
3. Pressinfg the button and releasing it after 4 beeps changes the IP
address mode from fixed to DHCP and vice versa
4. Pressing the button and releasing it after 6 beeps restarts the
network interface.
Displays the current or the IP address of the unit
Current:
Lights to indicate that the power consumtion is shown in the
display
IP Address: Lights to indicate that the IP Address is shown in the display
Indicates, wether a power output is switched on
Hardware Installation
1. Install mounting brackets.
The Unit comes with brackets for mounting in a rack. To mount the
device into a rack, please perform the following procedure:
I. Attach the mounting brackets to the unit, using the four retaining screws
provided for each of the brackets.
II. Choose a mounting position for the brackets (several options).
III. Align the mounting holes of brackets with the notched hole on the vertical rail
and attach with the retaining screws.
2. Connect the input and output power cables.
3. Connect your Ethernet cable to the unit.
4. Switch on the Ipower Switch Classic.
Note :
The default setting for the way to get an IP address is DHCP. If the unit can’t get an IP from a
present DHCP server, the IP address will remain 192.168.0.216
3
4
English Manual
English Manual
Network
5. Web Interface
Index
1. Provides network information for the
IPowerSwitch.
2. The network setting can be changed
here.
3. The default ID is “snmp”, the password
is “1234”.
System Information
Provide the General Information
for the IPower Switch, including:
• Model No.
• Name
• Location
• Contact
• Firmware Version
• MAC Address
Treshold
Shows the warning and overload value
setting
ID
Status:
Indicates the IPower Switch’s power
consumption and status.
Change the ID and password.
The default ID is “snmp”,
The password is ‘”1234”.
Control
Status:
1. Indicates the Ipower Switch’s power
consumption and status.
2. Select the outlet by check box first and
click the on or off button to control the
IPower Switch power output.
Email
• In case of an SMNP-event or warning ,
the unit can send out an email
message to a pre-defined account.
• Only support the input of anemail
server with a domain name.
• The message in the email will show as
below:
Control:
The default ID is “snmp” and
password is “1234”.
• Indicate OutletA~H status order
0 : means the power off.
1 : means the power on.
5
6
English Manual
English Manual
Trap
FCC Warning
Defines the IP address, to send event traps to.
The default ID is “snmp”, the Password is
“1234”.
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired
operation.
CE Statement, EMC Compatibilty
This device complies with EN Standards EN55022 and EN55024 according to the relevant EC EMC
Directive. It must be used with shielded cables only to maintain EMC compatibility.
Dieses Produkt entspricht den einschlägigen EMV Richtlinien der EU und darf nur zusammen mit
abgeschirmten Kabeln verwendet werden.
6. Technical Specifications
Interface
RJ45
Ethernet
Nominal Input Frequency
47~63 Hz Full Range
LED Indicators
Indicator
(1)yellow LED (1) red LED
Current Meter
Range
Resolution
Precision
3 digits
0A~20A (True RMS)
0A~20A: 0.1A
0A~20A: +/-2%+/-0.1AMP
Alarm
Audible
Seven Segment
Operation & Environment
Operating Temperature
Relative Humidity
Storage Temperature
1. Warning- 1 beep per second
2. Overload- 3 beeps per second
Warning and Overload - Meter flashes once per second
-5 - 45 degree C
0 - 95%
-25 - 65 degree C
LINDY Herstellergarantie
LINDY gewährt für dieses Produkt über die gesetzliche Regelung hinaus eine zweijährige
Herstellergarantie ab Kaufdatum. Die detaillierten Bedingungen dieser Garantie finden Sie auf der
LINDY Website aufgelistet bei den AGBs.
WEEE (Waste of Electrical and Electronic Equipment),
Recycling of Electronic Products
In 2006 the European Union introduced regulations (WEEE) for the collection and recycling of all waste
electrical and electronic equipment. The wheelie bin symbol shown indicates that this product must not
be disposed of with household waste. Instead the product must be recycled in a manner that is
environmentally friendly. For more information on how to dispose of this product, please contact your
local recycling centre or your household waste disposal service. Each individual EU member state has
implemented the WEEE regulations into national law in slightly different ways. Please follow your
national law when you want to dispose of any electrical or electronic products.
More details can be obtained from your national WEEE recycling agency.
Germany / Deutschland
Die Europäische Union hat mit der WEEE Direktive umfassende Regelungen für die Verschrottung und
das Recycling von Elektro- und Elektronikprodukten geschaffen. Diese wurden von der Bundesregierung
im Elektro- und Elektronikgerätegesetz – ElektroG in deutsches Recht umgesetzt. Dieses Gesetz
verbietet vom 24.März 2006 an das Entsorgen von Elektro- und Elektronikgeräten über die
Hausmülltonne! Diese Geräte müssen den lokalen Sammelsystemen bzw. örtlichen Sammelstellen
zugeführt werden! Dort werden sie kostenlos entgegen genommen. Die Kosten für den weiteren
Recyclingprozess übernimmt die Gesamtheit der Gerätehersteller.
LINDY No 32657, 32658
1st Edition, September 2008
www.lindy.com
7
8

advertisement

Related manuals

Download PDF

advertisement