BFT ARGO Industrial Sectional Door Operator Installation Manual
विज्ञापन
विज्ञापन
8
027908 3 4 7 0 6 0
OPERATORS FOR INDUSTRIAL SECTIONAL DOORS
Attenzione! Leggere attentamente le “Avvertenze” all’interno! Caution! Read “Warnings” inside carefully! Attention! Veuillez lire attentivement les Avertissements qui se trouvent à l’intérieur! Achtung! Bitte lesen Sie aufmerksam die „Hinweise“ im Inneren! ¡Atención¡ Leer atentamente las “Advertencias” en el interior! Let op! Lees de “Waarschuwingen” aan de binnenkant zorgvuldig!
QUICK INSTALLATION
REMOVING THE COVER
M
230Volt
PHOT
TUBE ARRANG
EMENT
B
1
3
2
V1
1
V1
10 mm
V2
(Fig. C4)
10 mm
5 mm
20 mm
A
C
V2
4
2
5
6
7
8
ARGO -
3
D
ADJUSTING THE LIMIT SWITCHES
E
Power ON LED
Fuse
1,6 AT
Display plus programming keys
Courtesy lamp
Palmtop programmer connector,
1 2
3 4
5 6 7
8 9 10
11 12 13
14 15
17
16
Optional board connector
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
O ptional SCS-IO module
4 -
ARGO
1 2 3 4 5 6 7
F
OPENING-CLOSING TORQUE AUTOSETTING
A
MEMORIZING REMOTE CONTROLS
+
OK
OK
x 2
B
G
C
D
OK
OK
x 2
ARGO -
5
115
22
226.5
226.5 min
65.5 min.
180 max
341 max
H
Cable entry from above
Cable entry from wall
TO OPEN ( =OFF)
Cable entry from below
24V 230V
250
200
150
100
50
0
1
400
350
300
1,5 2
ø 250
ø 225
ø 200
ø 175
ø 150
ø 125
ø 100
Average pulley diameter [mm]
2,5 3 3,5
Door height [m]
4 4,5 5 5,5 6
6 -
ARGO
J
I
REMOTE TRANSMITTER PROGRAMMING
K
Connection of 1 untested device
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
1
2
T X 1
PHOT
R X 1
3
4
1
2
5
Connection of 1 tested device
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
1
2
T X 1
Connection of 2 tested devices
PHOT
R X 1
3
4
1
2
5
SCS - IO
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 3 4 5 6 7
1
2
1
2
TX1
TX2
PHOT
RX1
3
4
1
2
5
RX2
3
4
1
2
5
Serial Connection Via Scs1 Card
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 3 4 5 6 7
1
2
TX1
1
2
TX2
BAR
RX1
3
4
1
2
5
RX2
3
4
1
2
5
L
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
1
2
T X 1
BAR
R X 1
3
4
1
2
5
M
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
1
2
T X 1
BAR
R X 1
3
4
1
2
5
SCS - IO
N
O
ARGO -
7
Press the OK key
Control unit software version
N. total manoeuvres (in tens)
N. manoeuvres since latest maintenance (in tens)
N. radio control devices memorised
ACCESS TO MENUS
Scroll up
Scroll down
Cancel/return to main menu
Confirm/Switch on display
See PARAMETERS MENU
See LOGIC MENU
- +
- +
- +
- +
OK
OK
OK
OK
OK
+/-
OK OK
See RADIO MENU
OK
LIMIT SWITCH ADJUSTMENT
(Fig. F)
Logic Description
partial opening input activated
START input activated
STOP input activated
PHOT input activated
SAFETY EDGE input activated
CLOSE input activated
OPEN input activated opening limit switch activated closing limit switch activated reverse due to obstacle autoset function is running
WARNING! Obstacle detection function is not active
photocell test error safety edge test error mosfet test error shunt test error encoder test error thermal cutout error optional module communication error
35.40
Set torque threshold %
Maximum motor torque %
ARGO -
13
INSTALLATION MANUAL
WARNING! Important safety instructions. Carefully read and comply with the
Warnings booklet and Instruction booklet that come with the product as incorrect installation can cause injury to people and animals and damage to property. They contain important information regarding safety, installation, use and maintenance. keep them handy for future reference.
1) GENERAL SAFETY
- The units making up the machine and its installation must meet the requirements of the following European Directives: 2004/108/EEC, 2006/95/EEC,
98/37/EEC, 89/106/EEC and later amendments. For all countries outside the
EEC, it is advisable to comply with the above-mentioned standards, in addition to any national standards in force, to achieve a good level of safety.
- The Firm disclaims all responsibility resulting from improper use or any use other than that for which the product has been designed, as indicated herein, as well as for failure to apply Good Practice in the construction of entry systems (doors, gates, etc.) and for deformation that could occur during use.
- Make sure the stated temperature range is compatible with the site in which the automated system is due to be installed.
- Do not install the product in an explosive atmosphere.
- Disconnect the electricity supply before performing any work on the system. nipolar thermal-magnetic circuit breaker with a contact separation of at least
3.0 mm.
- Make sure that upline from the mains power supply there is a residual current circuit breaker that trips at 0.03A.
- Make sure the earth system has been installed correctly: earth all the metal parts belonging to the entry system (doors, gates, etc.) and all parts of the system featuring an earth terminal.
- Installation must be carried out using safety devices and controls that meet standard EN 12978.
- Apply all safety devices (photocells, safety edges, etc.) required to keep the area free of crushing, dragging and shearing hazards.
- The motor cannot be installed on panels incorporating doors (unless the motor can be activated when the door is open)
- If the automated device is installed at a height of less than 2.5 m or is accessible, the electrical and mechanical parts must be suitably protected.
moving parts. Unless the control is key operated, it must be installed at a height of at least 1.5 m and in a place where it cannot be reached by the public attach a Warning sign to the structure.
- If there are no instructions already, attach a label near the operating device, in a permanent fashion, with information on how to operate the manual release.
- Make sure that nothing can be crushed between the guided part and sur-
- Once installation is complete, make sure the motor has the right settings and that the safety and release systems are working properly.
- Only use original spare parts for any maintenance or repair work. The Firm disclaims all responsibility for the correct operation and safety of the automated system if parts from other manufacturers are used.
less explicitly authorized by the Firm.
- Dispose of packaging materials (plastic, cardboard, polystyrene, etc.) in accordance with the provisions of the laws in force. Keep nylon bags and polystyrene out of reach of children.
Warning! For connection to the mains power supply, use a multicore cable with a cross-section of at least 4x1.5mm
2
of the kind provided for by the regulations mentioned above (by way of example, type H05 VV-F cable can be used with a cross-section of 4x1.5mm
2
). To connect auxiliary equipment, use wires with a cross-section of at least 1 mm
2
.
Have an omnipolar circuit breaker installed with a contact separation of at least 3 mm and featuring overload protection, suitable for cutting the
Only use pushbuttons with a capacity of 10A-250V or more.
any other mechanical hazards. All critical points must be protected by safety
devices in accordance with the provisions of the regulations in force.
CHECKING THE AUTOMATED DEVICE
checks meticulously:
Check the correct functioning of all safety devices (limit microswitches, photocells, sensitive edges etc.).
for by the standards in force.
Check the opening and closing operations with the control devices in use.
.
USE OF THE AUTOMATED DEVICE
Since the automated device can be remote controlled via a remote control or start button, hence with the door out of sight, it is vital that all safety devices be checked frequently to ensure they are in perfect working order. If there is any
You are strongly advised to keep children well out of range of the automated system. Depending on the type of control applied, the automated device must be used in compliance with the installer’s instructions in order to operate without endangering people, animals or property.
CONTROL
The purpose of using the automated device is to enable motorized door opening and closing. There are various options when it comes to the control system
(manual, remote control, access control with magnetic badge etc.) depending on the installation’s needs and characteristics. See the relevant instructions for the various control system options.
People due to use the automated device must be instructed how to control and use it.
MAINTENANCE
.
In the event of any anomalous functioning which cannot be resolved, disconnect the power supply and contact a specialised technician (installer). Whilst the automation is out of order, activate the manual release to allow manual opening and closing.
SCRAPPING
WARNING!
disposed of in accordance with the regulations in force. There are no particular hazards or risks involved in scrapping the automated system. For the purpose of recycling, it is best to separate dismantled parts into like materials (electrical parts - copper - aluminium - plastic - etc.).
DISMANTLING
WARNING!
If the automated system is being dismantled in order to be reassembled at another site, you are required to: to be damaged.
imity of the terminals, e.g. with cable clamps.
Also add more clips to the limit device wires, to the transformer primary or secondary wires, and to the wires connected to the printed circuit.
During installation, the power supply cable must be stripped in order for the earthing wire to be connected to the appropriate terminal, but the active wires must be left as short as possible. The earthing wire must be the last to
WARNING: extremely low safety voltage cables must be phisically separated from low voltage cables.
Access to the electrical compartment or to limit switches must be allowed to skilled personnel only.
Compliance with current safety rules with regard to people, animals and property
measures must be taken to avoid risks of injury due to crushing, in the area where the pinion and rack mesh, and
14 -
ARGO
INSTALLATION MANUAL
2) GENERAL INFORMATION
Actuator for motorizing residential and industrial sectional doors.
Its compact design and mounting versatility mean the drive can be applied in
3) TECHNICAL SPECIFICATIONS
P o
Max. power input:
L i w e m i
r s u p
t s w p l y : ti c h :
C o u r t e s y il g h :t
Operating temperature range:
M a x .
d o o r s i z e :
M a x .
t o r q u e :
L u b ir c a it o n :
2 3 0 V ± 1 0 % , 5 0 / 6 0 H z ( * )
70W
E l e c t r o n i c E N C O D E R m o d
Output shaft MAX. 18 rpm e l
2 4 V b u l b ~ m a x .
2 5 W , E 1 4
-15°C / +55°C
2 0
5 5 m
2
N m
L fi e it m e g r e a s e d
Manual operation:
Protection rating:
N o i s e l e v e :l
Knob-operated mechanical release
IP 40
< 7 0 d B A
10 kg Operator weight:
D i m e n s i o n s :
Accessories power supply:
Flashing light connection:
S e e F i g .
H
24V~ (180 mA)
24V max 25W
F u s e s : S e e F i g .
D
Built-in Rolling-Code radio-receiver: frequency 433.92MHz
(*) Special supply voltages to order.
Usable transmitter versions:
All ROLLING CODE transmitters compatible with .
4) REMOVING THE COVER Fig. A
5) TUBE ARRANGEMENT Fig. B
6) INSTALLING THE OPERATOR Fig. C
5) CABLE ENTRY FIG. I
6) MANUAL RELEASE (See USER GUIDE -FIG. Y-).
----------------------------------------------------------
7) WIRING
TERMINAL DESCRIPTION
JP2
Transformer wiring
JP10
1-2
Motor wiring
Antenna input for built-in radio-receiver board (1:BRAIDING 2:
SIGNAL)
3-4
3-5
3-6
3-7
8-9
10-11
START/OPEN INPUT (N.O.)
STOP input (N.C.) If not used, leave jumper inserted
PHOTOCELL input (N.C.) If not used, leave jumper inserted
SAFETY EDGE input (N.C.) If not used, leave jumper inserted
12-13
14-15
16-17
24V~ max. 180mA output - power supply to photocells or other devices.
24V~ Vsafe max. 180mA output - power supply to transmitters photocells with test.
(NO contact) / Output 1 height programmable
PARTIAL OPENING/CLOSE input (N.O.)
4-5 (SCS-IO)
(NO contact) / Output 2 Height programmable
6-7 (SCS-IO)
Gate open light/2nd radio channel output (NO contact)
7.1) SAFETY DEVICES
Note: only use receiving safety devices with free changeover contact.
Fig. L: Connection of 1 untested device (photocell or safety edge).
Fig. M: Connection of 1 tested device (photocell or safety edge).
Fig. N: Connection of 2 tested devices (photocells or safety edges). This connection is made possible via the SCS-IO optional module only.
8) ADJUSTMENTS
RECOMMENDED ADJUSTMENT SEQUENCE:
Adjusting the limit switches (Fig. E)
Autoset (Fig. F)
Programming remote controls (Fig. G)
Setting of parameters/logic, where necessary
8.1) PARAMETERS MENU
(TABLE “A” PARAMETERS)
(TABLE “B” LOGIC)
Logic Description
Add Start Key
associates the desired key with the Start command
Add 2ch Key
associates the desired key with the 2nd radio channel command
Read
Checks a key of a receiver and, if memorized, returns the number of the receiver in the memory location (from 01 to
64) and number of the key (T1-T2-T3 or T4).
Erase List
WARNING! Erases all memorized remote controls from the receiver’s memory.
Read receiver code
Displays receiver code required for cloning remote controls.
ON = Enables remote programming of cards via a previously memorized W LINK transmitter. It remains enabled for 3 minutes from the time the W LINK remote control is last pressed.
OFF=W LINK programming disabled.
- IMPORTANT NOTE: THE FIRST TRANSMITTER MEMORIZED MUST BE
IDENTIFIED BY ATTACHING THE KEY LABEL (MASTER).
KEY CODE: this code is required to subsequently clone the radio transmitters.
The Clonix built-in on-board receiver also has a number of important advanced features:
To use these advanced features, refer to the universal handheld programmer’s instructions and to the CLONIX Programming Guide, which come with the universal handheld programmer device.
Used to set the programmer’s language on the display.
Restores the controller’s default factory settings.
D panel.
the control unit commands the door to perform a full cycle (opening followed by closing), during which the minimum torque value required for the door to move is set automatically.
During this stage, it is important to avoid breaking the photocells’ beams and not to use the START and STOP commands or the display.
Once this operation is complete, the control unit will have automatically set the optimum torque values. Check them and, where necessary, edit them as described in the programming section.
WARNING: Check that the force of impact measured at the points provided for by standard EN 12445 is lower than the value laid down by standard EN 12453.
ARGO -
15
INSTALLATION MANUAL
Warning!! While the autoset function is running, the obstacle detection function is not active. Consequently, the installer must monitor the automated system’s movements and keep people and property out of range of the automated system.
Limit switch adjustment procedure:
2) The display reads CLOSE. Use the UP and DOWN keys to move the door to the
3) If prompted by the display, turn the adjustment ring: anticlockwise if the display reads UP; clockwise if the display reads DOWN. Once you have reached the reads PRG.
4) The display reads OPEN. Use the UP and DOWN keys to move the door to the
If the display reads KO, it means adjustment was not successful.
This may be caused by:
- the ESC key being pressed before adjustment was completed
- stored travel being too short
9) SCS OPTIONAL MODULES
9.1) SERIAL CONNECTION VIA SCS1 CARD (Fig. O)
The VENERE D control panel’s special serial inputs and outputs (SCS1) make the centralized connection of a number of automated devices possible. That way, all the automated devices connected can be opened or closed with a single command.
Connect all VENERE D control panels using twisted pair cabling only, proceeding as shown in the diagram in Fig. O.
When using a telephone cable with more than one pair, it is essential to use wires from the same pair.
The length of the telephone cable between one unit and the next must not be greater than 250 m.
starting by entering a MASTER control panel that will have control over all the others, which therefore have to be set as SLAVE units (see logic menu).
Also set the Zone number (see parameters menu) in the range 0 to 127.
The zone number allows you to create groups of automated devices, each of which answers to the Zone Master. Each zone can have only one Master: the Master of zone 0 also controls the Slaves of the other zones.
9.2) Interface with WIEGAND systems via SCS-WIE module.
Refer to the SCS-WIE module’s instructions.
9.3) Expanding inputs and outputs via the SCS-IO optional module.
The SCS-IO optional module can be used to add 2 inputs and 2 outputs to the
VENERE-D board (Fig. D).
To activate the connection between SCS-IO and VENERE-D, you need to plug the
SCS-IO module into the relevant connector and then set the ZONE parameter to 129.
At this point, the 2 boards are synchronized and the SCS-IO board’s inputs/outputs are managed by the VENERE-D board.
5
10
99
99
0 129
1
1
99
99
0
1
120
99
1
10
10
99
99
99
40
75
75
99
99
10
40
0
50
50
Automatic Closing Time
Opening motor torque
Closing motor torque
Speed during opening
Speed during closing
Slow-down distance
Partial opening
Zone
Output 1 height programmable
Output 2 height programmable
Automatic closing time [s]
Opening torque [%]
Sets sensitivity to obstacles during opening (1=max., 99=min.) The autoset feature sets this parameter automatically to a value of 10%. The user can edit this parameter based on how sensitive the door needs to be to obstacles.
Closing torque [%]
Sets sensitivity to obstacles during closing (1=max., 99=min.) The autoset feature sets this parameter automatically to a value of 10%. The user can edit this parameter based on how sensitive the door needs to be to obstacles.
Running speed during opening [%]
Sets the running speed that the door must reach during opening, as a percentage of the maximum speed the actuator can reach. Should this parameter be edited, it will be followed by a complete opening/closing cycle for setting purposes (reported by the message “SET” appearing on the display), during which obstacle detection is not enabled.
Running speed during closing [%]
Sets the running speed that the door must reach during closing, as a percentage of the maximum speed the actuator can reach. Should this parameter be edited, it will be followed by a complete opening/closing cycle for setting purposes (reported by the message “SET” appearing on the display), during which obstacle detection is not enabled.
Slow-down distance [%]
Sets the approach distance to reach the travel limit. This distance is travelled at low speed.
Partial opening [%]
Adjusts partial opening percentage compared to total opening in “Partial open” mode.
Zone []
Sets the zone number of the door included in the serial connection for commands via central controllers. Zona=128 not used.
Zone=129 Use of optional SCS -I0 module.
The output between terminals 14-15 is activated when the door exceeds the opening percentage set with this parameter (1% = door closed, 99%
= door open).
The output between terminals 4-5 on the SCS-IO optional module is activated when the door exceeds the opening percentage set with this parameter (1% = door closed, 99% = door open).
16 -
ARGO
INSTALLATION MANUAL
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
OFF
OFF
Automatic
Closing Time
Block Pulses
ON Switches automatic closing on
OFF 3 Step
door closed: opens
door open: closes
during closing: stops and opens again
door closed: opens
door open: closes
during closing: stops and does not switch on tca (stop)
OFF Pre-alarm
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
Deadman
ON Deadman mode during closing: opening operation performed in automatic mode; closing operation continues as long as the control key is held down. (CLOSE).
OFF Pulse operation (standard)
Photocells during opening
Photocell test
Safety edge testing
Master/Slave
closing, movement is reversed immediately.
OFF: When beam is broken, photocells are active during both opening and closing. When beam is broken during closing, movement is reversed only once the photocell is cleared.
ON Switches photocell testing on
If disabled (OFF), it inhibits the photocell testing function, enabling connection of devices not equipped with supplementary test contacts.
ON Switches safety edge testing on
If disabled (OFF), it inhibits the safety edge testing function, enabling connection of devices not equipped with supplementary test contacts
ON Control panel is set up as the Master unit in a centralized connection system.
OFF Control panel is set up as a Slave unit in a centralized connection system.
Fixed code
Remote control programming
Gate open light or
2nd radio channel
Selection
START - OPEN
Selection
PEDESTRIAN -
CLOSE
ON Enables wireless memorizing of transmitters: (Fig. K)
1- Press in sequence the hidden key (P1) and normal key (T1-T2-T3-T4) of a transmitter that has already been memorized in standard mode via the radio menu.
2- Press within 10 sec. the hidden key (P1) and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new transmitters.
This mode does not require access to the control panel.
OFF Disables wireless memorizing of transmitters.
Transmitters are memorized only using the relevant Radio menu.
ON The output between terminals 6-7 on the optional SCS-10 module is set as Gate open light: in this case, the 2nd radio channel controls pedestrian opening.
OFF The output between terminals 6-7 on the optional SCS-10 module is set as 2nd radio channel
ON Input between terminals 3-4 works as OPEN.
OFF Input between terminals 3-4 works as START
ON Input between terminals 16-17 works as CLOSE.
OFF Input between terminals 16-17 works as PEDESTRIAN
Reversing motion
ON Reverses motion of standard rotation (See Fig.I).
OFF Standard rotation (See Fig.I).
ARGO -
17
USER’S MANUAL: MANUAL OPERATION-
FIG. Y
A B
C
38 -
ARGO
Green
Red