BritTherm Domestic Pro Installation & Operating Instructions Manual
PDF
Dokument
Annons
Annons
DP15 Installation & Operating Instructions Please read these instructions carefully before installation Contents General Information..................................................................................3 Pump Liquid & Operating Conditions...................................................4 Pump Diagram............................................................................................5 Installation...................................................................................................6 Gaskets........................................................................................................7 Venting.........................................................................................................8 Control Panel.............................................................................................9 Pressure Curve.........................................................................................10 Operating Modes......................................................................................11 Fault Finding...............................................................................................12 Guarantees.................................................................................................13 General Information These instructions guide you through the installation and operation of this BritTherm™ Central Heating Circulator. The Domestic Pro is a high efficiency Circulator which is perfectly suited to operate in: • • • Single zone heating systems Multi zone heating systems Underfloor heating systems The Pump incorporates a permanent magnet motor with differential pressure control which enables its performance to be aligned with actual system demand. It has a connection size of 1 ½”, a maximum head of 6 metres and a port to port distance of 130mm making it perfect for domestic applications. Pump Liquid & Operating Conditions BritTherm™ Pumps require clean, thin, non-aggressive liquids to operate correctly and prevent damage to their internal components. The liquids used must not contain any solid Liquids running through circulation pumps used on heating systems must comply with the accepted standards of quality especially in domestic applications. Liquids that do not comply will void the warranty offered with the circulation Pump. Pump Diagram Installation Attention: Ensure the Pump is installed with the motor shaft in the horizontal position. Attention: The Pump liquid may be scalding hot and under pressure. Before removing head screws the system either requires draining, or the Pump needs to be isolated. Gaskets Attention: Fit the two gaskets when the Pump is mounted correctly between the flow and return pipes. Venting Attention: The Pump liquid may be scalding hot and under pressure so proceed with caution when bleeding the Pump. Control Panel Find Pressure Curve on next page. 1. Screen showing actual working power 2. Light field indicating AUTO mode 3. Lowest manual speed option 4. Middle manual speed option 5. Highest manual speed option 6. Light field indicating NIGHT mode 7. Button for selecting NIGHT mode 8. Button for selecting each pump setting 9. CP1: Min. constant pressure curve 10. CP2: Max. constant pressure curve 11. PP1: Min. proportion pressure curve 12. PP2: Max. proportion pressure curve Pressure Curve Operating Modes I - (Minimum) the Pump runs at a constant fixed speed and therefore on a constant curve. II - (Medium) the Pump runs at a constant fixed speed and therefore on a constant curve. III - (Maximum) the Pump runs at a constant fixed speed and therefore on a constant curve. *Quick venting of the Pump can be achieved using speed III for a short period. AUTO - the power rises and falls in line with the system flow rate. *Ex - factory setting. (Night Mode) - the Pump reduces power automatically, After 2 hours it drops to its minimum level (5-10 Watts). *After 7 hours the pump reverts to its original setting. PP1 - (Proportional Pressure 1) the duty point moves up/down on the lowest proportional pressure curve. Head pressure is then reduced and increased at falling and rising heating demand respectively. PP2 - (Proportional Pressure 2) the duty point moves up/down on thehighest proportional pressure curve. Head pressure is then reduced and increased at falling and rising heating demand respectively. CP1 - (Constant Pressure 1) the duty point of the Pump moves out or in the constant pressure curve depending on heating demand. Head pressure remains constant irrespective of heating demand. CP2 - (Constant Pressure 2) the duty point of the Pump moves out or in the constant pressure curve depending on heating demand. Head pressure remains constant irrespective of heating demand. Fault Finding Before starting any work on the pump please ensure the electricity supply is turned off and cannot be accidentally switched back on at any time Fault Control Panel Pump doesn’t run at all Light is off Noise in the system Noise in the Pump Insufficient Cause Remedy A) One fuse is blown Replace fuse B) The current/ voltage operated circuit breaker has tripped out Cut in the circuit break C) The Pump is defective Replace Pump Only shows power A) Failure of electricity supply, might be too low Check the supply falls within the specified range Light on for power and pump settings A) Air in the system Vent the system B) The flow is too high Reduce the suction head A) Air in Pump Let the Pump run, it vents itself over time B) Inlet pressure is too low Increase the inlet pressure. Check the air volume in the expansion tank if installed A) Pump perfomance is too low Increase the suction head Light on for power and pump settings Light on for power and pump setting Guarantee Registration This Pump is covered against manufacturing malfunction by a 6 year guarantee. The guarantee is only valid if the Pump has been installed correctly, the system is maintained adequately, and the guarantee is registered within 30 days of purchase. The Pump is covered for a free of charge replacement should malfunction occur within the first 3 years from the date of sale. From 3 years and up to 6 years the Pump is covered for a replacement at 50% of the original sale price. To register go to www.BritTherm.co.uk and click You will need: Register a Guarantee • Date of purchase • Address where pump is fitted • Name of supplier • Supplier invoice number Please retain your purchase invoice as it may be required in the event of a guarantee claim. To make a claim please contact BritTherm by email in the first instance: [email protected] ">
/
Ladda ner
Bara en vänlig påminnelse. Du kan visa dokumentet här. Men viktigast av allt, vår AI har redan läst det. Den kan förklara komplexa saker på ett enkelt sätt, svara på dina frågor på vilket språk som helst och hjälpa dig att snabbt navigera även de längsta eller mest komplicerade dokumenten.
Annons