Truma B 10 / B 14 Boiler Operating instructions

The Truma B 10 / B 14 Boiler is a L.P. gas and electric storage water heater designed to provide hot water in caravans, mobile homes, and other vehicles. It's also possible to use it in other situations after consultation with Truma.

PDF
Document
Truma B 10/14 Manual: AI Support & PDF | Manualzz

Advertisement

Advertisement

/

Advertisement

Key features

  • LP gas and electric operation

  • 10 or 14 liters water tank

  • Pressure relief valve

  • Red indicator lamp

  • 12V and 230/240V connection

Frequently asked questions

To drain the water heater, disconnect power for the water pump, open hot water taps, and open the safety/drain valve. The water heater will drain directly to the outside via the drain valve. Check that the water contents have been completely drained (10 liters or 14 liters).

The operating pressure for the gas supply is 2.75 kPa (AUS – Propane, NZ – LPG).

Always remove the cowl cover before operating the water heater. Open the gas cylinder and the stop cock valve in the gas supply line. Switch on the water heater at the switch on the control panel.

The red indicator lamp lights up if there is a failure. To unlock, switch off the appliance, wait 10 minutes, and switch on again.

To operate the electrical heating element, insert the plug into the socket and then turn it on with the switch. The electric heating element is operational when you can see the mark on the switch.