- Industrial & lab equipment
- Electrical equipment & supplies
- Batteries & accessories
- Rechargeable batteries
- Bacharach
- PGM-IR
- Instructions
advertisement
▼
Scroll to page 2
of 4
Battery Pack For Gas Monitors User Guide 3015-5848 Rev. 0 – December 2015 Product Leadership • Training • Service • Reliability Battery Pack For Gas Monitors Introduction Thank you for selecting Bacharach products for your gas monitor needs. To ensure safe operation of this equipment, please read and follow the information contained in this manual. Technical Specifications Model: Capacity: Battery Cell: Input Charging Port: Output Port (III) to Monitor: Charging Time: Size: Weight: Power Indicator: Built-in Protection Circuit: BP90 87 Watt-Hour Lithium-Ion Acceptable Input Voltage Range DC 12-24V Connector Size 5.5 x 2.1mm Port III: 16V, 19V, 24V selectable Connector Size: 5.5 x 2.5mm Maximum Output Current: 3A ~3.5 A 4-6 Hours 7.5” x 4.5” x 0.9” (or 186 x 114 x 22.5mm) 1.4lb (621g) 4 level LED indicator Over-charge – Over-discharge Over current – Over temperature Short circuit protection Components 2 P/N:3015-5848 Rev. 0 Battery Pack For Gas Monitors Operation 1. Charge the Battery: This battery can be charged from any 110V or 220V AC power source with the provided AC charger. Plug the AC charger into the battery input port to charge the battery. CAUTION: DO NOT connect any device to the battery output port when the battery is under charging. The port III output voltage will be ~ 12.6V when the battery is charging. The LED on the right will light up red. The remaining three LEDs will light up green and indicate the charge level of the battery. One green LED indicates 30-60% battery charge, two green LEDs indicate 6090% battery charge, and all three green LEDs indicate a full charge. NOTE: New batteries may stop charging before they are fully charged. If your battery stops charging, remove the charger from the battery and reinsert it, reinitiating the charge cycle. This may happen several times during the first few charges and is normal. Battery may become warm during charging process. It is recommended to recharge the battery before it is fully exhausted. 2. Set Output Voltage: Output port III can output three different voltages: 16V, 19V and 24V. When you plug an output cord into the port, a LED will light up to indicate the current active output voltage. The LEDs from right to left are 16V, 19V and 24V. NOTE: Bacharach PGM-IR and H25-IR PRO dual-power instruments are designed to run at 16V. To change the output voltage, first remove the output cable from the port (voltage locks whenever an output cable is present.) Press and hold the “CHECK” button for three seconds. The LED that represents the currently selected voltage will begin to flash. Press the check button again to switch to the next voltage. When the desired voltage is reached, wait five seconds for the LED to stop flashing and the voltage will be selected. 3. Connect To Monitor: Once the battery is charged and the correct voltage is selected, connect the battery to your monitor as described in the user manual. 3 P/N:3015-5848 Rev. 0 Battery Pack For Gas Monitors Safety Information • • • • • • • • • • • • Do not connect this battery directly with any other battery, neither in serial nor in parallel. This battery is designed to provide power independently only. Do not disassemble or modify the battery. The battery contains safety and protection devices which if damaged may cause the battery to heat, ignite or explode. Never puncture, drop, crush, throw, hit, open or modify the battery or casing. Do not submerge the battery in water. Do not expose the battery to heat above 60°C (140°F) or incinerate. Do not place the battery in microwave ovens, high-pressure containers or on induction cookware. Do not place the battery in or near fire, or in direct sunlight. Heating the battery can damage the safety circuitry, which can cause additional heating, rupture, or ignition. Do not insert any foreign objects into the charging port. Immediately discontinue use of the battery if while storing, charging or using, the battery emits an unusual smell, feels hot to touch, changes color or shape or appears abnormal in any other way. In the event the battery leaks and the fluid gets into one’s eye, do not rub the eye. Rinse well with water and immediately seek medical attention. If left untreated, the battery fluid could cause damage to the eye. Always dispose of used batteries in accordance with local regulations. If this battery is misused or abused, it can result in personal injury from heat, smoke, fire or explosion. Website: www.mybacharach.com • E-mail: [email protected] United States Bacharach, Inc. 621 Hunt Valley Circle New Kensington, PA 15068 USA Phone: 724-334-5051 Fax: 724-334-5723 Ireland Bacharach - Europe 114A Georges Street Lower Dun Laoghaire, Dublin Ireland Phone: +353 1 284 6388 Fax: +353 1 284 6389 Canada Bacharach - Canada 20 Amber St. Unit #7 Markham, Ontario L3R SP4 Canada Phone: 905-470-8985 Fax: 905-470-8963 Printed in U.S.A. 4 P/N:3015-5848 Rev. 0
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement