MAJOR TECH MT643 Temperature Datalogger User Manual
PDF
Document
Advertentie
Advertentie
Temperature Datalogger
User Manual
=== pa
- — ";_—_—
Contents Page
1. Features (oli meneame peonnanonconerentare on ee
2.Discription ......... ercoceovanvraresnececeneranevecocureraracoa e raca oceano eee
3.LED Status Guide....... Ennrnanane ne ARRERRBRKERTRARERKEKARARAEKTRARRERLTRTALT 5
4.Qperating Instructions es penirvenernrenermenenencerreccacaras O
5.Software Operation .............++1eseecercirecie iD
6.Specifications.....….….....….….…cscereerienseneenenenen canne „еее Э
7.Battery Replacement...........e.=m.c.e.eeznirverercercercea rad O
15
1.Features
* Memory for 31,808 readings
Status Indication
* USB Interface
*User-Selectable Alarm
* Analysis software
*Multi-mode to start logging
*Long battery life
*Selectable measuring cycle: _
*1s, 25, 55, 10s, 30s, Tm, 5m, 10m, 30m, 1hr, 2hr, 3hr, 6hr, 12hr
2.Discription
1-Protective cover
2-USB connector to PC port
3-Alarm LED(red)
4-Record LED(green)
5-Mounting clip
6-Type-K anode
7-Type-K cathode
8-Start Button.
LED Status Guide
LED GREEN
LED RED
3.LED Status Guide
LEDs
Indication Action
REC ALM
Both LED lights OFF
Logging not active
Or Low Battery
start logging Replace battery
and download the data
REC ALM
One green flash every
10 sec. *
Logging, no alarm
condition**
Green double flash
every 10 sec, *
Delayed start
To start, hold the start button
until Green flash 4 times
REC ALM
Red double flash every
30 sec. *
-Logging, low
Temperature alarm. — logging, it will stop automatically.
Red Triple flash every |No data will be lost. Replace
30 sec. * battery and download data
-Logging, high
temperature alarm.
Red single flash every
20 sec.
-Low Battery****
REC ALM
Red single flash every [It won't logging until the Type-K
2 sec. probe connect to the logger.
-Type-K not connect
to the logger
REC ALM
Red and green single |Download data
flash every 60 sec.
-Logger memory full
A.Operating Instructions
*Setup the DataLogger by software before use it.
* Under the Manual mode, press and hold the button for 2s,
Datalogger start to measure, and LED indicates the function at the
same time.( see LED FLASH INDICATION for details.)
«Under the Automatic mode, you can choose the delay start time,
if you choose to delay zero second, the DataLogger will start to
measure after setup in software immediately, LED indicate the
function at the same time.(see LED FLASH INDICATION for details.)
*During measurement, the green LED indicates the working state by
flashing with the frequency setup in the software.
if the Type-K probe is not connect to the logger, the red light will
single flash every 2 sec. it won't record the data, connect the Type-K
probe to the logger, it will start record the data normally.
*When datalogger memory full, Red LED and Green will flash every
60 sec.
* As the battery power is not sufficient, red LED will flash every 60
sec for indication.
* Press and hold the button for 2s untill Red LED sequencly flash four
times, and then logging will stop, or connect the datalogger to the
host and download the data, the datalogger will stop automaticlly.
*DataLogger data can be read time after time, the readings you are
checking are the real time measured ones.(1 to 32000 readings);
if set the datalogger the last data will be losed,
+1f the logger is logging, the Type-K probe is disconnected , the
foager will stop logging automaticly.
*Without battery, the latest 1 hours (the most) data will be lost,
Other data can be read in software after battery is installed.
. *When replacing the battery, turn off the meter and open the battery
cover. Then, replace the empty battery with a new 1/2AAA 3.6V
battery and replace the cover.
*To save power, the loggers LED flashing-cycle can be changed to
20s or 30s via the supplied software.
* To save power, alarm LEDs for temperature can be disabled via the
supplied software.
rer
*When the battery is low, all operations will be disabled automatically.
NOTE: Logging automatically stops when the battery weakens (loggec
data will be retained). The supplied software is required to restart
fogging and to download logged data.
5.Software Operation
1. Datalogger Setup
Click on the icon on the menu bar. The Setup window will appear
as shown below; descriptions for each field in the Setup window
are eli ted directly below for er
The se Sampling Setup field instructs the DATA LOGGER to log readings
at a specific rate. You can input specific sampling rate data at the
left Combo box and select the time unit at the right Combo box.
*The LED Flash Cycle Setup field can be set 105/205/30s by the user
depending on the requirement. By selecting “Noa Light” .option,
there will be no flash there by increase the battery life.
*The Alarm Setup field allows the user to set HIGH and LOW
temperature limits.
* There are two start methods at the Start Mehod field:
(1)Manual:Chose this item, the user need to click the logger button
to start data logging.
(2)Automatic:Choose this item the logger will start data logging
automatic after the delay time,
User can set a specific delay time, if the delay time is 0 second, the
logger will start logging immediately.
Click on the SETUP button to save changes, Press the DEFAULT button
to set the Logger to factory default condition. Press the CANCEL
button to abort the setup.
Notes:All stored data will be permanently erased when Setup 15
finished. To enable you to save the data before it is lost, click Cancel
and then you need to download data.
The battery might be exhausted before logger finish specified sample
points. Always ensure that the remaining power in the battery is
sufficient for completing your logging task, If in doubt, we recommend
that you always install a fresh battery before logging critical data.
2. Download Data v7
To transfer the readings stored in the Logger to the PC:
«Connect the DATA LOGGER to the USB port.
* Open the Datalogger software program if it is not still running
* Click the Download icon i
*The Window shown below will appear, Click DOWNLOAD to begin
transferring data.
“Press Download. to stop logging and
Da data from Jogger. or r Cancel to.
ex. DLE TS
Once the data is successfully downloaded, the window shown below
Range - to
-328 to 24
Accuracy +
overall Max.
to 24 hours
ta oto
to ‚6 10
Tt-5101 or
on rate,
ambient & use of Alarm
7.Battery Replacement
Only use 3.6V lithium batteries. Before replacing the battery, remove
the model from the PC. Follow diagrammatic and explaination steps
1 throught 4 below:
*With a pointed object(d.g. a small screwdriver or similar), open the
casing, Lever the casing off in the direction of the arrow.
«Pull the data logger from the casing.
*Replace/Insert the battery into the battery compartment observing
the right polarity. The two displays briefly light up for control
purposes{alternating, green, yellow, green).
*Slide the data logger back into the casing until it snaps into place.
Now the data logger is ready for programing.
Note;
Leaving the model plugged into the USB port for longer than necessary
will cause some of the battery capacity to be lost.
Warning: Handle lithium batteries carefully, observe warnings on
battery casing. Dispose of in accordance with local regulations.
">
/
Downloaden
Even een vriendelijke herinnering. U kunt het document hier bekijken. Maar het belangrijkste is dat onze AI het al heeft gelezen. Het kan complexe dingen in eenvoudige bewoordingen uitleggen, uw vragen in elke taal beantwoorden en u helpen snel te navigeren, zelfs in de langste of meest ingewikkelde documenten.