YASKAWA Varispeed CIMR-V7AZ20P1 Quick Start Manual
PDF
Tài liệu
Quảng cáo
Quảng cáo
OMRON YASKAWA Motion Control B.V. Varispeed V7 Series QUICK START GUIDE COMPACT GENERAL-PURPOSE INVERTER (VOLTAGE VECTOR CONTROL) MODEL: CIMR-V7AZ 200 V CLASS SINGLE-PHASE 0.1 to 4.0 kW 200 V CLASS 3-PHASE 0.1 to 7.5 kW 400 V CLASS 3-PHASE 0.37 to 7.5 kW Upon receipt of the product and prior to initial operation, read these instructions thoroughly and retain them for future reference. YASKAWA MANUAL NO. TOEP C710606 06A General Precautions • Some drawings in this manual are shown with protective covers or shields removed in order to show detail with more clarity. Make sure all covers and shields are replaced before operating the product. • This manual may be modified when necessary because of improvements to the product, modifications, or changes in specifications. • To order a copy of this manual, or if your copy has been damaged or lost , contact your OMRON YASKAWA Motion Control B. V. (Hereinafter called the OYMC) representatives. • OYMC is not responsible for any modification of the product made by the user, since that will void the guarantee. Safety Information The following conventions are used to indicate precautions in this document. Failure to heed precautions provided in this document can result in serious or possibly even fatal injury or damage to the products or to related equipment and systems. Indicates precautions that, if not heeded, could possibly result WARNING in loss of life or serious injury. Indicates precautions that, if not heeded,could result in CAUTION relatively serious or minor injury, damage to the product, or faulty operation. Failure to heed a precaution classified as a caution can result inserious consequences depending on the situation. Precautions for UL/cUL Marking • Do not connect or disconnect wiring, or perform signal checks while the power supply is turned ON. • The Inverter internal capacitor is still charged even after the power supply is turned OFF. To prevent electric shock, disconnect all power before servicing the Inverter, and then wait at least one minute after the power supply is disconnected. Confirm that all indicators are OFF before proceeding. • Do not perform a withstand voltage test on any part of the Inverter. The Inverter is an electronic device that uses semiconductors, and is thus vulnerable to high voltage. • Do not remove the Digital Operator or the blank cover unless the power supply is turned OFF. Never touch the printed circuit board (PCB) while the power supply is turned ON. • This Inverter is not suitable for use on a circuit capable of delivering more than 18,000RMS symmetrical amperes, 250 volts maximum (200V class Inverters) or 480 volts maximum(400V class Inverters). 3 CAUTION Use 75 C copper wires or equivalent. Low voltage wires shall be wired with Class I Wiring. Precautions for CE Markings • Only basic insulation to meet the requirements of protection class I and over voltage category II is provided with control circuit terminals. Additional insulation may be necessary in the end product to conform to CE requirements. • For 400 V class Inverters, make sure to ground the supply neutral to conform to CE requirements. • For conformance to EMC directives, refer to section 3 in this document. For details, refer to the following document: Document No. EZZ008390 for English version Receiving CAUTION • Do not install or operate any Inverter That is damaged or has missing parts. Failure to observe this caution may result in injury or equipment damage. Mounting CAUTION • Lift the Inverter by the heatsink. When moving the Inverter, never lift it by the plastic case or the terminal covers. Otherwise, the main unit may fall and be damaged. • Mount the Inverter on nonflammable material (i.e., metal). Failure to observe this caution may result in a fire. • When mounting Inverters in an enclosure, install a fan or other cooling device to keep the intake air temperature below 122°F (45°C) for IP20 (open chassis type), or below 105°F(40°C) for NEMA1 (TYPE1). Overheating may cause a fire or damage the Inverter. • The VS-V7AZ generates heat. For effective cooling, mount it vertically. Refer to the figure in Mounting Dimensions on section 3. 4 Wiring WARNING • Only begin wiring after verifying that the power supply is turned OFF. Failure to observe this warning may result in an electric shock or a fire. • Wiring should be performed only by qualified personnel. Failure to observe this warning may result in an electric shock or a fire. • When wiring the emergency stop circuit, check the wiring thoroughly before operation. Failure to observe this warning may result in injury. • Always ground the ground terminal according to the local grounding code. Failure to observe this warning may result in an electric shock or a fire. • For 400V class, make sure to ground the supply neutral. Failure to observe this warning may result in an electric shock or a fire. • If the power supply is turned ON during the FWD(or REV) RUN command is given, the motor will start automatically. Turn the power supply ON after verifying that the RUN signal is OFF. Failure to observe this warning may result in injury. • When the 3-wire sequence is set, do not make the wiring unless the multi-function input terminal parameter is set. Failure to observe this warning may result in injury. CAUTION • Verify that the Inverter rated voltage coincides with the AC power supply voltage. Failure to observe this caution may result in personal injury or a fire. • Do not perform a withstand voltage test on the Inverter. Performing withstand voltage tests may damage semiconductor elements. • To connect a Braking Resistor, Braking Resistor Unit, or Braking Unit, follow the Procedure described in this manual. Improper connection may cause a fire. • Always tighten terminal screws of the main circuit and the control circuits. Failure to observe this caution may result in a malfunction, damage or a fire. • Never connect the AC main circuit power supply to output terminals U/T1, V/T2 or W/T3. The Inverter will be damaged and the guarantee will be voided. • Do not connect or disconnect wires or connectors while power is applied to the circuits. Failure to observe this caution may result in injury. • Do not perform signal checks during operation. The machine or the Inverter may be damaged. • To store the constant with an ENTER command by communications, be sure to take measures for an emergency Stop by using the external terminals. Delayed response may cause injury or damage the machine. 5 Operation WARNING • Only turn ON the input power supply after confirming the Digital Operator or blank cover(optional) are in place. Do not remove the Digital Operator or the covers while current is flowing. Failure to observe this warning may result in an electric shock. • Never operate the Digital Operator or DIP the switches with wet hands. Failure to observe this warning may result in an electric shock. • Never touch the terminals while current is flowing, even if the Inverter is stopping. Failure to observe this warning may result in an electric shock. • When the fault retry function is selected, stand clear of the Inverter or the load. The Inverter may restart suddenly after stopping. (Construct the system to ensure safety, even if the Inverter should restart.) Failure to observe this warning may result in injury. • When continuous operation after power recovery is selected, stand clear of the Inverter or the load. The Inverter may restart suddenly after stopping. (Construct the system to ensure safety, even if the Inverter should restart.) Failure to observe this warning may result in injury. • The Digital Operator stop button can be disabled by a setting in the Inverter. Install a separate emergency stop switch. Failure to observe this warning may result in injury. WARNING • If an alarm is reset with the operation signal ON, the Inverter will restart automatically. Reset an alarm only after verifying that the operation signal is OFF. Failure to observe this warning may result in injury. • When the 3-wire sequence is set, do not make the wiring unless the multi-function input terminal parameter is set. Failure to observe this warning may result in injury. • If n001=5, a Run command can be received even while changing a constant. If sending a Run command while changing a constant, such as during a test run, be sure to observe all safety precautions. Failure to observe this warning may result in injury. • If the Bi-directional Function Selection (n145) is set to 1 (enabled), the motor can rotate in the reversed direction against the input command. Be sure to observe all safety precautions. Failure to observe this warning may result in injury. 6 CAUTION • Never touch the heatsinks, which can be extremely hot. Failure to observe this caution may result in harmful burns to the body. • It is easy to change operation speed from low to high. Verify the safe working range of the motor and machine before operation. Failure to observe this caution may result in injury and machine damage. • Install a holding brake separately if necessary. Failure to observe this caution may result in injury. • If using an Inverter with an elevator, take safety measures on the elevator to prevent the elevator from dropping. Failure to observe this caution may result in injury. • Do not perform signal checks during operation. The machine or the Inverter may be damaged. • All the constants set in the Inverter have been preset at the factory. Do not change the settings unnecessarily. The Inverter may be damaged. Maintenance and Inspection WARNING • Never touch high-voltage terminals on the Inverter. Failure to observe this warning may result in an electrical shock. • Disconnect all power before performing maintenance or inspection, and then wait at least one minute after the power supply is disconnected. Confirm that all indicators are OFF before proceeding. If the indicators are not OFF, the capacitors are still charged and can be dangerous. • Do not perform withstand voltage test on any part of the VS-V7AZ. The Inverter is an electronic device that uses semiconductors, and is thus vulnerable to high voltage. • Only authorized personnel should be permitted to perform maintenance, inspections, or parts replacement. (Remove all metal objects (watches, bracelets, etc.) before starting work.) Failure to observe these warnings may result in an electric shock. CAUTION • The control PCB board employs CMOS ICs. Do not touch the CMOS elements. They are easily damaged by static electricity. • Do not connect or disconnect wires, connectors, or the cooling fan while power is applied to the circuit. Failure to observe this caution may result in injury. 7 Others WARNING • Never modify the product. Failure to observe this warning can result in an electric shock or injury and will invalidate the guarantee. CAUTION • Do not subject the Inverter to halogen gases, such as fluorine, chlorine, bromine, and iodine, at any time even during transportation or installation. Otherwise, the Inverter can be damaged or interior parts burnt. 8 CONTENTS 1. Installation. . . . . . . . . . . . . . . . . . 2. Wiring . . . . . . . . . . . . . . . . . . . . . 3. Control Circuit Terminals . . . . . . 4. Operator Use . . . . . . . . . . . . . . . 5. Start up Steps . . . . . . . . . . . . . . . 6. Parameter list . . . . . . . . . . . . . . . 7. Monitors . . . . . . . . . . . . . . . . . . . 8. Faults and alarms . . . . . . . . . . . . 10 13 14 16 18 22 30 33 9 1.5 (0.06) 1. Installation H2 H1 H 4-d W1 W Rated Voltage 8.5 (0.33) D Model V7AZ W H Dimesions (mm) D W1 H1 MCCB (A) Supply Recommendations 20P1 68 128 76 56 118 5 20P2 68 128 76 56 118 5 2 20P4 68 128 108 56 118 5 2 Wire (mm2) 2 Three 20P7 68 128 128 56 118 10 2 Phase 21P5 108 128 131 96 118 20 2 200 VAC 22P2 108 128 140 96 118 20 3.5 24P0 140 128 143 128 118 30 5.5 25P5 180 260 170 164 244 50 8 27P5 180 260 170 164 244 60 8 B0P1 68 128 76 56 118 5 B0P2 68 128 76 56 118 5 2 Single B0P4 68 128 131 56 118 10 2 Phase B0P7 108 128 140 96 118 20 3.5 200 VAC B1P5 108 128 156 96 118 20 5.5 2 B2P2 140 128 163 128 118 40 5.5 B4P0 170 128 180 156 118 50 8 40P2 108 128 92 96 118 5 2 40P4 108 128 110 96 118 5 2 40P7 108 128 140 96 118 5 2 Three 41P5 108 128 156 96 118 10 2 Phase 42P2 108 128 156 96 118 10 2 400 VAC 43P0 140 128 143 128 118 20 2 44P0 140 128 143 128 118 20 2 45P5 180 260 170 164 244 30 5.5 47P5 180 260 170 164 244 30 5.5 10 Input Filter Specifications φd XL H Model V7AZ Y W Dimensions Filter 3G3MV- W L H Y X d PFI2010-SE 82 194 50 62 181 5.3 20P1 20P2 20P4 20P7 21P5 22P2 24P0 25P5 27P5 PFI2020-SE 111 169 50 91 156 5.3 PFI2030-SE 144 174 50 120 161 5.3 PFI2050-SE 184 304 56 150 264 6.0 PFI1010-SE 71 169 45 51 156 5.3 91 156 5.3 B0P1 B0P2 B0P4 B0P7 B1P5 B4P0 40P2 40P4 PFI1020-SE 111 169 50 PFI1040-SE 175 174 50 PFI3005-SE 111 164 45 91 156 5.3 PFI3010-SE 111 169 45 91 156 5.3 PFI3020-SE 144 174 50 120 161 5.3 PFI3030-SE 184 304 56 150 264 6.0 40P7 41P5 42P2 43P0 44P0 45P5 47P5 11 EMC Installation and V7 L1 L2L3PE L N PE Shield Cable Control Panel Metal Mounting Plate L N L1 L2 L3 Filter V7 Series Inverter R S T Ground bonds (remove any paint) Shield Cable Ground Bonds (remove any paint) Ground bonds (remove any paint) Schaffner Filter U V W V7 Series Inverter R S Max.20 m Motor Cable Motor CIMR-V7AZB0P1 to B4P0 Mounting Dimensions 30 mm (1.18 in.) OR MORE 100 mm (3.94 in.)AIR OR MORE 100 mm (3.94 in.)AIR OR MORE 12 Ground bonds (remove any paint) Shield Cable Ground Bonds (remove any paint) Motor 30 mm (1.18 in.) OR MORE Metal Mounting Plate U V W Max.20 m Motor Cable CIMR-V7AZ40P2 to 47P5 CIMR-V7AZ20P1 to 24P0 Shield Cable Control Panel 2. Wiring DC Reactor (Optional) Thermal Overload Braking Resistor Relay (Optional) Short-circuit bar MCCB Power Supply For Single-phase. Use R/L1 and S/L2. FOR RUN/STOP REVERSE RUN/STOP Grounding FAULT RESET MUL TI-STEP SPEED REF 1 Multi-function FAULT Contact Output MULTI-STEP SPEED REF 2 JOG COMMAND Frequency Ref. Pulse Train Input Shield connection terminal Reference Pulse Train (Max. 33 kHz) Frequency Setting Power Supply (+12 V 20 mA) Frequency Reference 0 to +10 V (20 kΩ) 4 to 20 mA/0 to 20 mA (250 Ω) Digital Operator Frequency Setting Potentiometer MEMOBUS Communications RS-485/422 Max. 19.2 kbps Shielded Terminal Resistance (1/2 W, 120 Ω) FREQUENCY AGREED RUNNING Multifunction input EXTERNAL FAULT (NO CONTACT) 250 VAC 1 A or less* 2 30 VDC 1 A or less Multi-function Photocoupler Output +48 VDC 50 mA or less Analog Monitor Output 0 to +10 VDC (2 mA) Output Frequency Analog Monitor/Pulse Monitor Selectable P Shielded twisted-pair cable : Only basic insulation (protective class 1, overvoltage category II) is provided for the control circuit terminals. Additional insulation may be necessary in the end product to conform to CE requirements. *1. Short-circuit bar should be removed when connecting a DC reactor. *2. Minimum permissible load: 5 VDC, 10 mA (as reference value) Control circuit terminals Main circuit terminals Ground terminals 13 3. Control Circuit Terminals Symbol Input Name Function S1 Multi-function input 1 Set by parameter n50 Forward/Stop S2 Multi-function input 2 Set by parameter n51 Reverse/Stop S3 Multi-function input 3 Set by parameter n52 Default external fault. S4 Multi-function input 4 Set by parameter n53 Default fault Reset. S5 Multi-function input 5 Set by parameter n54 Default Multi-step speed reference 1 S6 Multi-function input 6 Set by parameter n55 Default Multi-step speed reference 2 S7 Multi-function input 7 Set by parameter n56 Default JOG command SC Sequence input common Common for S1 through S7 Master speed reference train RP input Signal Level Photo-coupler Insulation, 8 mA art 24 VDC Note: NPN is the default setting for these terminals. No external power supply is required. Refer to connections shown below. Pulse train input signal Max. 33 kHz Frequency Reference power supply DC power supply for frequency reference setting 20mA at 12 VDC FR Frequency Reference Input Input terminal for frequency reference setting 0 to10VDC 20k FC Frequency Reference common Common for frequency reference use 4 to 20 mA 0 to 20 mA MB Multi-function output: NC Set by parameter n57 Factory setting: Fault MC Multi-function output common Common for MA and MB use Relay output 1A max. at 30 VDC and 250 VAC P1 Photo-coupler output 1 Set by parameter n58 Factory setting: RUNNING Output P2 Photo-coupler output 2 Set by parameter n59 Factory setting: FREQUENCY AGREED FS MA Multi-function output: NO Photo-coupler output , 50A max at +48VDC PC Photo-coupler output common Common for P1 and P2 14 AM Analogue Monitor output Set by parameter n65 (output frequency) AC Analogue Monitor common Common for AM use 2mA max. at 0 to 10VDC. Selecting Input Method Selecting Sequence Input Method By using SW1, NPN or PNP input can be selected as shown below. By using SW1, NPN or PNP input can be selected as shown below 24 V SW1 24 V SW1 24 V 24 V SW1 NPN GND (Default setting) 0.1 µ S1 to S7 3.3 k SW1 PNP (Default setting) 0.1µ 3.3k S1 to S7 GND S1 to 0.1 µ S7 3.3 k GND GND 360 0.1µ 360 S1 to S7 24 VDC +/−10 % 3.3k 360 360 24 V DC +/-10% SC SC SC SC GND GND GND GND 15 4. Operator Use Appearance MIN Data Display Indicators (Setting Monitor item indicators) Operation keys FREQUENCY adjuster Name Function Data display Displays relevant data, items, such as frequency reference, output frequency and parameter set values. FREQ adjuster Sets the frequency reference within a range between 0Hz and the maximum frequency. FREF Indicator The frequency reference can be monitored or set while this indicator is lit. MAX FOUT Indicator The output frequency of the inverter can be monitored while this indicator is lit. IOUT indicator The output current of the inverter can be monitored while this indicator is lit. MNTR indicator The values set in U-01 through U-19 are monitored while this indicator is lit. F/R indicator The direction of rotation can be selected while this indicator is lit when operating the inverter with the run key. LO/RE indicator The operating of the inverter though the Digital Operator or according to the set parameters is selected while this indicator is lit. Note: The status of this indicator can be only monitored while the inverter is in operation. Any RUN command input is ignored while this indicator is lit. PRGM indicator The parameter in n01 through to n179 can be set or monitored while this indicator is lit. Note: while the inverter is in operation, the parameters can be only monitored and only some parameters can be changed. Any RUN command input is ignored while this indicator is lit. Mode Key Switches the setting and monitor item indicator in sequence. Parameter being set will be cancelled if this key is pressed before entering the setting. Increment Key Increases multi-function monitor numbers, parameter numbers and parameters set values. Decrement Key Decreases multi-function monitor numbers, parameter numbers and parameters set values. Enter Key 16 Enters multi-function monitor numbers, parameter numbers and internal data values after they are set or changed. Appearance RUN STOP RESET Name Function RUN Key Starts the inverter running when the CIMZ-V7AZ is in operation with the Digital Operator. STOP/RESET Key Stops the inverter unless parameter n07 is not set to disable the STOP Key. 17 5. Start up Steps The following seven steps describe the recommended minimum operations to allow the V7 to control a connected motor in typical configuration, to allow simple operation in the quickest time: Step 1 – initial checks 1-1) Checkpoints before connecting the power supply. Check the power supply if it is of the correct voltage. CIMR-V7AZA2****: Three phase 200 to 230VAC CIMR-V7AZB****: Single phase 200 to 240VAC (Wire R/L1 and S/L2) CIMR-V7AZA4****: Three phase 380 to 460VAC 1-2) Make sure that the motor output terminals (U/T1, V/T2, W/T3) are connected to the motor. 1-3) Ensure that the control circuit terminals and the control device are wired correctly. 1-4) Make sure that all control terminals are turned off. 1-5) Set the motor to no-load status (i.e. not connected to the mechanical system) Step 2 – Connecting the power supply and check the display status 1-1) After conducting the checks in step-1, connect the power supply. 1-2) If the display is normal when the power is connected it will read as follows; RUN indicator: flashes ALARM indicator: off Setting/monitor indicators: FREF, FOUT or IOUT is lit. Data display: displays the corresponding data for the indicator that is lit. When fault has occurred, the details of the fault will be displayed. In that case, refer to user’s manual and take necessary action. 18 Step 3 – Initializing parameters To initialize the drive parameters to factory defaults, set parameter n001 = 12. This will set the V7 to accept start/stop commands in what in termed “2-wire control”, i.e. 1 wire for a motor forward/stop command, and 1 wire for a motor reverse/stop command. Key Indicator sequence Display Explanation example Power On Press the Mode Key repeatedly until the PRGM indicator is lit. Press the Enter Key. The data of n001 will be displayed. Use the Increment or Decrement Key to set n001 to 12. The display will be lit. Press the Enter Key so that the set value will be entered and the data display will be lit. The parameter number will be displayed. In approx. 1 s. Step 4 – Set the motor rated current This parameter is used for the electronic thermal function for motor overload detection (OL1). By correctly setting this, the V7 will protect an overloaded motor from burning out. Read the rated current (in amps) on the motor nameplate, and enter this into parameter n036. The example to the below shows entering a value of 1.8Amps. Key sequence Indicator Display Explanation example Displays the parameter number. Use the Increment or Decrement Key until n036 is displayed. Press the Enter Key. The data of n036 will be displayed. Use the Increment or Decrement Key to set the rated motor current. The display will flash. Press the Enter Key so that the set value will be entered and the data display will be lit. In approx. The parameter number will be displayed. 1 s. 19 Step 5 – Set the motor rated frequency This is the maximum frequency the motor can run and allows the V7 to properly control the motor. Read the rated frequency (in Hz) on the motor nameplate, and enter this into parameters n011. Step 6 – Set the operation command This is the method for motor run and stop commands (i.e. how the inverter will start and stop the motor). The two basic operations are for the RUN and STOP/RESET keys on the Digital Operator, or for one of multi-function inputs through the control circuit terminals. To set the operation command, enter the appropriate value into parameter n003: 0 = RUN and STOP/RESET keys on the Digital Operator are enabled. 1 = Multi-function inputs through the control circuit terminals. The diagram to the below shows how to connect a switch to start/stop the motor in the forward direction in “2-wire control”. Set parameter n003=1. To enable a separate switch for reverse rotation on control terminal S2, set parameter n051=2, parameter n050=1 (This is actually the factory default setting for n051 and n050). 20 Step 7 – Set the frequency reference This is the method for selecting the source for the motor speed command. The factory default is for the digital Operator. Frequency reference can also come from the potentiometer on the operator, an external potentiometer, an analog output from a PLC, or up to 8 pre-programmed speeds held in the inverter and selected via the multi-function inputs. For example, to accept frequency reference from an external potentiometer, or a 0-10V analog out from a PLC, set parameter n004=2. IM (0 TO +10 V) MASTER SPEED FREQUENCY REFERENCE FS FREQUENCY SETTING POWER +12 V, 20 mA FR 2 kΩ FC (0 V) 21 6. Parameter list Parameter No. 22 Description Factory Setting Parameter No. Description 1 n016 Min. Output Frequency 1.3Hz (Note 4) 0 (Note1, 4) n017 Min. Output Frequency Voltage 12.0V (Note 2,4) Factory Setting n001 Parameter Access n002 Control Mode Selection n003 RUN Command 0 n018 Selecting Setting Unit for Acceleration/deceleration Time n004 Frequency Reference Selection 1 n019 Acceleration Time 1 10.0s n005 Stopping Method Selection 0 n020 Deceleration Time 1 10.0s n006 Reverse Run Prohibit 0 n021 Acceleration Time 2 10.0s n007 Stop Key Selection 0 n022 Deceleration Time 2 10.0s n008 Frequency Reference Selection in Local Mode 1 n023 S-curve Selection n009 Frequency Reference Setting Method From Digital Operator 0 n024 Frequency Reference 1 (Master Frequency Reference) 6.00Hz n010 Detecting Fault Contact of Digital Operator 0 n025 Frequency Reference 2 0.00Hz n011 Max. Output Frequency 50.0Hz n026 Frequency Reference 3 0.00Hz n012 Max. Voltage 200V (Note 2) n027 Frequency Reference 4 0.00Hz n013 Max. Voltage Output Frequency 50.0Hz n028 Frequency Reference 5 0.00Hz n014 Mid. Output Frequency 1.3Hz (Note 4) n029 Frequency Reference 6 0.00Hz n015 Mid. Output Frequency Voltage 12.0V (Note 2,4) n030 Frequency Reference 7 0.00Hz 0 0 Parameter No. Description Factory Setting Parameter No. Description Factory Setting n031 Frequency Reference 8 0.00Hz n047 Frequency reference bias operation mode selection (UP/DOWN command 2) 0 n032 Jog Frequency 6.00Hz n048 Frequency reference bias value (UP/DOWN command 2) 0.0% n033 Frequency Reference Upper Limit 100% n049 Analog frequency reference fluctuation limit level (UP/DOWN command 2) 1.0% n034 Frequency Reference Lower Limit 0% n050 Multi-function Input Selection 1 (Terminal S1) 1 n035 Setting/displaying Unit Selection for Frequency Reference 0 n051 Multi-function Input Selection 2 (Terminal S2) 2 n036 Motor Rated Current (Note 3) n052 Multi-function Input Selection 3 (Terminal S3) 3 n037 Electronic Thermal Motor Protection Selection 0 n053 Multi-function Input Selection 4 (Terminal S4) 5 n038 Electronic Thermal Motor Protection Time Constant Setting 8min n054 Multi-function Input Selection 5 (Terminal S5) 6 n039 Selecting Cooling Fan Operation 0 n055 Multi-function Input Selection 6 (Terminal S6) 7 n040 Motor Rotation Direction 0 n056 Multi-function Input Selection 7 (Terminal S7) 10 n041 Acceleration Time 3 10.0s n057 Multi-function Output Selection 1 0 n042 Deceleration Time 3 10.0s n058 Multi-function Output Selection 2 1 n043 Acceleration Time 4 10.0s n059 Multi-function Output Selection 3 2 n044 Deceleration Time 4 10.0s n060 Analog Frequency Reference Gain 100% 0% n045 Frequency reference bias step amount (UP/DOWN command 2) 0.00Hz n061 Analog Frequency Reference Bias n046 Frequency reference bias accel/decel rate (UP/ DOWN command 2) 0 n062 Filter Time Constant for Analog Frequency Reference 0.10s 23 Parameter No. 24 Description Factory Setting Parameter No. Description Factory Setting n063 Watchdog Error Operation Selection (For SI-T/V7) 0 n079 Frequency Reference Bias (FBIAS) Value n064 Frequency Reference Loss Detection Selection 0 n080 Carrier Frequency Selection n065 Monitor Output Type 0 n081 Momentary Power Loss Ridethrough Method 0 n066 Monitor Item Selection 0 n082 Automatic Retry Attempts 0 n067 Monitor Gain 1.00 n083 Jump Frequency 1 0.00Hz n068 Analog Frequency Reference Gain (Voltage input from Operator) 100% n084 Jump Frequency 2 0.00Hz n069 Analog Frequency Reference Bias (Voltage input from Operator) 0% n085 Jump Frequency 3 0.00Hz n070 Analog Frequency Reference Filter Time Constant (Voltage input from Operator) 0.10s n086 Jump Frequency Range 0.00Hz n071 Analog Frequency Reference Gain (Current input from Operator) 100% n087 Cumulative operation time function selection 0 n072 Analog Frequency Reference Bias (Current input from Operator) 0% n088 Cumulative operation time 0H n073 Analog Frequency Reference Filter Time Constant (Current input from Operator) 0.10s n089 DC Injection Braking Current 50% n074 Pulse Train Frequency Reference Gain 100% n090 DC Injection Braking Time at Stop 0.5s n075 Pulse Train Frequency Reference Bias 0% n091 DC Injection Braking Time at Startup 0.0s n076 Pulse Train Frequency Filter Time Constant 0.10s n092 Stall Prevention During Deceleration n077 Multi-function Analog Input Function 0 n093 Stall Prevention Level During Acceleration 170% n078 Multi-function Analog Input Signal Selection 0 n094 Stall Prevention Level During Running 160% 10% (Note3) 0 Parameter No. Description Factory Setting Parameter No. Description 0.00Hz n111 Slip Compensation Gain 0.0s (Note4) 2.0s (Note4) Factory Setting n095 Frequency Detection Level n096 Overtorque Detection Function Selection 1 0 n112 Slip Compensation Time Constant n097 Overtorque/Undertorque Detection Function Selection 2 0 n113 Slip Compensation During Regenerative Operation 0 n098 Overtorque Detection Level 160% n114 Number of Transmission Cycle Error Detection (For SI-T/V7) 0 n099 Overtorque Detection Time 0.1s n115 Stall Prevention Above Base Speed During Run 0 n100 Hold Output Frequency Saving Selection 0 n116 Acceleration/deceleration Time during Stall Prevention 0 n101 Speed Search Deceleration Time 2.0s n117 Undertorque Detection Function Selection 1 0 n102 Speed Search Operation Level 150% n118 Undertorque Detection Level 10% n103 Torque Compensation Gain 1.0 n119 Undertorque Detection Time 0.1s n104 Torque Compensation Time Constant 0.3s (Note4) n120 Frequency Reference 9 0.00Hz n105 Torque Compensation Iron Loss (Note3) n121 Frequency Reference 10 0.00Hz n106 Motor Rated Slip (Note3) n122 Frequency Reference 11 0.00Hz n107 Motor Line-to-neutral Resistance (Note3) n123 Frequency Reference 12 0.00Hz n108 Motor Leakage Inductance (Note3) n124 Frequency Reference 13 0.00Hz n109 Torque Compensation Voltage Limiter 150% n125 Frequency Reference 14 0.00Hz n110 Motor No-load Current (Note3) n126 Frequency Reference 15 0.00Hz 25 Parameter No. 26 Description Factory Setting Parameter No. Description 0.00Hz n143 Read sequence input twice 0 0 n144 Stop Distance Enlarge Gain 1.00 Factory Setting n127 Frequency Reference 16 n128 PID Control Selection n129 PID Feedback Gain 1.00 n145 Bi-direction Selection n130 Proportional Gain (P) 1.0 n146 Frequency Offset Selection n131 Integral Time (I) 1.0s n147 Max. Voltage Output Frequency (2nd Motor) 50.0Hz n132 Derivative Time (D) 0.00 n149 Pulse Train Input Scaling 2500 (25kHz) n133 PID Offset Adjustment 0% n150 Pulse Monitor Output Frequency Selection 0 n134 Upper Limit of Integral Values 100% n151 MEMOBUS Timeover Detection 0 n135 Primary Delay Time Constant for PID Output 0.0s n152 MEMOBUS Frequency Reference and Frequency Monitor unit 0 n136 Selection of PID Feedback Loss Detection 0 n153 MEMOBUS Slave Address 0 n137 PID Feedback Loss Detection Level 0% n154 MEMOBUS BPS Selection 2 n138 PID Feedback Loss Detection Time 1.0s n155 MEMOBUS Parity Selection 0 n139 Auto-tuning Selection 0 n156 Transmission Waiting Time 10ms n140 Max. Output Frequency (2nd Motor) 50.0Hz n157 RTS Control n141 PTC Thermistor Selection 0 n158 Max. Voltage (2nd Motor) n142 Motor Temperature Filter Timer 0.25s n159 Mid. Output Frequency (2nd Motor) 0 0 200V (Note 2) 12.0V (Note 2,3) Parameter No. Description Factory Setting Parameter No. Description Factory Setting n160 Min. Output Frequency (2nd Motor) 12.0V (Note 2,3) n176 Constant Copy Function Selection rdy n161 Motor Rated Current (2nd Motor) (Note 2,3) n177 Constant Read Selection Prohibit 0 n162 Motor Rated Slip (2nd Motor) (Note 2,3) n178 Fault History - n163 PID Output Gain n179 Software Version No. - n164 PID Feedback Value Selection 0 n165 Externally-mounting type braking resistor overheat protection selection *8 0 n166 Input Open-phase Detection Level 0% n167 Input Open-phase Detection Time 0s n168 Output Open-phase Detection Level 0% n169 Output Open-phase Detection Time 0.0s n170 ENTER Command Operation Selection (MEMOBUS Communication) 0 n171 Frequency reference bias upper limit (UP/DOWN command 2) 0.0% n172 Frequency reference bias lower limit (UP/DOWN command 2) 0.0% n173 DC Injection Braking Proportional Gain 83 (0.083) n174 DC Injection Braking Integral Time Constant 25 (100ms) n175 Reducing Carrier Frequency Selection at Low Speed 0 (Note5) 1.0 Note: Refer to user‘s manual for complete list 1.Not initialized by constant initialization. 2.Upper limit of setting range and factory setting are doubled for 400V Class. 3.Depends on inverter capacity. Refer to user’s manual. 4.When control mode selection (n002) is changed, factory setting corresponds to the control mode. Refer to user’s manual. 5.Enabled (1) for 5.5kW and 7.5kW inverters 27 Multi-Function Inputs Value Function Multi-Function Outputs Value Function 2 Reverse/Stop 0 Fault output 3 4 5 6 7 8 External fault (NO) External fault (NC) Fault reset Multi-step reference 1 Multi-step reference 2 Multi-step reference 3 1 2 6 12 13 15 Running output Frequency agree Overtorque being Monitored (NO) Run mode Inverter ready Undervoltage in progress 10 JOG command Analogue Output Functions 12 13 17 External base block (NO) External base block (NC) Local/Remote selection Value 0 1 Function Output frequency Output current Note: Refer to user’s manual for full set value listings 28 Example of Parameter Settings PRGM PRGM PRGM PRGM Cancels set data PRGM In approximately 1s Key sequence Indicator Display example Explanation Power ON Press the Mode Key repeatedly until the PRGM indicator is lit. Use the Increment or Decrement Key to set the parameter number. Press the Enter Key. The data of the selected parameter number will displayed. Use the Increment of Decrement Key to set the data. At that time the display will flash. Press the Enter Key so that the set value will be entered and the data display will be lit. (see note 1) In approx. 1s The parameter number will be displayed. Note 1: To cancel the set value, press the Mode Key instead. The parameter will be displayed. Note 2: There are parameters that cannot be changed while the Inverter is in operation. Refer to the list of parameters. When attempting to change such parameters, the data display will not change by pressing the Increment or Decrement Key. 29 7. Monitors The V7AZ allows you to monitor various conditions, such as output current and status of multi-function inputs. This monitoring is performed via the “U” parameters. Key sequence Indicator Display example Explanation Power ON Press the Mode Key repeatedly until the PRGM indicator is lit. Use the Increment or Decrement Key to set the montior number. Press the Enter Key. The data of the selected montior number will displayed. Press the Enter or Mode Key. The monitor number will be displayed. 30 Constant No. Name U-01 Frequency reference Description Hz Frequency reference can be monitored. Hz Output frequency can be monitored. (FREF)*1 U-02 Output frequency U-03 Output current (same as FREF) (FOUT)*1 (Same as FOUT) A (IOUT)*1 Output current can be monitored. (Same as IOUT) U-04 Output voltage V Output voltage can be monitored. U-05 DC voltage V Main circuit DC voltage can be monitored U-06 Input terminal status - Input terminal status of control circuit U-07 Output terminal status - terminals can be monitored. Output terminal status of control circuit terminals can be monitored. U-08 Torque monitor % The amount of output torque can be U-09 Fault history (last 4 faults) - Last four fault history is displayed. U-10 Software No. - Software No. can be checked. U-11 Output power*2 KW Output power can be checked. U-12 Frequency offsets monitor Hz Frequency offsets can be monitored. monitored. When V/f control mode is selected, “----“ is displayed. U-14 ASCII code from the PLC - ASCII code from the PLC is displayed. U-15 Data reception error - Contents of MEMOBUS communication data reception error can be checked. (contents of transmission register No. 003DH are the same) U-16 PID Feedback % Input 100(%) Max. output frequency or equivalen. U-17 PID input % ±100(%). Where Max. output U-18 PID output % ±100(%). Where Max. output U-19 Frequency reference bias % ±100(%). Where Max. output frequency=100% frequency=100% monitor frequency=100% *1 The status indicator LED is not turned ON. *2 When in the vector control mode,”---“ will be displayed. 31 Input / Output terminal status Input terminal status 1: Terminal S1 is closed. 1: Terminal S2 is closed. 1: Terminal S3 is closed. 1: Terminal S4 is closed. 1: Terminal S5 is closed. 1: Terminal S6 is closed. 1: Terminal S7 is closed. Not used Output terminal status 1: Terminal MA-MC is closed. 1: Terminal P1-PC is closed. 1: Terminal P2-PC is closed. Not used Data reception error display 1: CRC error 1: Data length fault Not used 1: Parity error 1: Over run error 1: Framing error 1: Timeover Not used 32 8. Faults and alarms Fault Display Fault name and meaning Possible cause and remedy OC Overcurrent Output current is higher than 250% of inverter rated current. Check output for shortcircuit or ground fault. The load is too large, reduce it or use larger inverter. Check motor FLA rating compared to inverter and V/f setting. OV Overvoltage DC bus voltage has exceeded detection level. Load inertia is too large and the motor is regenerating. Increase deceleration time (n020 or n022). Connect an external braking resistor and set n092 to 1. Check braking resistor and wiring. UV1 Main circuit undervoltage Check mains power supply voltage and conDC bus voltage is below detec- nections. Check correct supply for inverter tion level. beeing used. Monitor for mains dips or interruptions. OH Unit overheat Refer to manual for installation guidelines Temperature inside the inverter and recommendations. Check cooling fan (if has exceeded 110°C fitted). Check v/f characteristic or reduce carrier frequency. OL1 Motor overload The inverter is protecting the motor from overload, based on an internal I2t calculation using n036 setting. EF Check and reduce the load. Check V/f characteristic (Vmax and Fmax). Increase the running speed of motor. Increas acceleration/deceleration times. External fault Check your control terminal wiring. An external fault has been input. A multi-function digital input has been set to 3 or 4. Run signal has to be removed before this can be reset. SER Sequence error Inverter has to be stopped when Local / (flashing) Sequence input when inverter is Remote switching attempted. running. Inverter must be stopped when Comms / Remote switching attempted. bb External Baseblock (flashing) An external baseblock command has been input. Check your control terminal wiring. A multi-function digital input has been set to 12 or 13. EF Sequence error has occurred Forward and reverse run signal have been (flashing) applied simultaniously. Note: Refer to user’s manual for full fault code listings 33 英文 No.4-4 (A4) メカトロ製品用 TOE Varispeed V7 Series QUICK START GUIDE YASKAWA ELECTRIC CORPORATION YASKAWA In the event that the end user of this product is to be the military and said product is to be employed in any weapons systems or the manufacture thereof, the export will fall under the relevant regulations as stipulated in the Foreign Exchange and Foreign Trade Regulations. Therefore, be sure to follow all procedures and submit all relevant documentation according to any and all rules, regulations and laws that may apply. Specifications are subject to change without notice for ongoing product modifications and improvements. © 2005 OMRON Yaskawa Motion Control. All rights reserved. MANUAL NO. TOEP C710606 06A Printed in Japan June 2005 05-5 03-1 1 ">
/
Tải xuống
Chỉ là một lời nhắc nhở thân thiện. Bạn có thể xem tài liệu ngay tại đây. Nhưng quan trọng nhất, AI của chúng tôi đã đọc nó. Nó có thể giải thích những điều phức tạp bằng những thuật ngữ đơn giản, trả lời các câu hỏi của bạn bằng bất kỳ ngôn ngữ nào và giúp bạn nhanh chóng điều hướng ngay cả những tài liệu dài nhất hoặc phức tạp nhất.
Quảng cáo