Lovato DME D122MID Installation Manual
PDF
Document
Advertisement
Advertisement
31100384 GB SINGLE-PHASE DIRECT CONNECTION ENERGY METER WITH M-BUS INTERFACE Installation manual I545 GB I 08 18 LOVATO ELECTRIC S.P.A. 24020 GORLE (BERGAMO) ITALIA VIA DON E. MAZZA, 12 TEL. 035 4282111 TELEFAX (Nazionale): 035 4282200 TELEFAX (International): +39 035 4282400 E-mail [email protected] Web www.LovatoElectric.com I CONTATORE DI ENERGIA MONOFASE A INSERZIONE DIRETTA CON INTERFACCIA M-BUS Manuale di installazione DME D122MID UE declaration: http://www.lovatoelectric.com/DMED122MID/DMED122MID/snp Dichiarazioni UE: http://www.lovatoelectric.com/DMED122MID/DMED122MID/snp WARNING! – Carefully read the manual before the installation or use. – This equipment is to be installed by qualified personnel, complying to current standards, to avoid damages or safety hazards. – Remove eventual dangerous voltage from the product before any maintenance operation on it. – The manufacturer cannot be held responsible for electrical safety in case of improper use of the equipment. – Products illustrated herein are subject to alteration and changes without prior notice. Technical data and descriptions in the documentation are accurate, to the best of our knowledge, but no liabilities for errors, omissions or contingencies arising therefrom are accepted. – A circuit breaker must be included in the electrical installation of the building. It must be installed close by the equipment and within easy reach of the operator. It must be marked as the disconnecting device of the equipment: IEC/EN 61010-1 § 6.11. – Fit the instrument in an enclosure or cabinet with minimum IP51 degree protection. – Clean the instrument with a soft dry cloth, do not use abrasives, liquid detergents or solvents. ATTENZIONE!! – Leggere attentamente il manuale prima dell’utilizzo e l’installazione. – Questi apparecchi devono essere installati da personale qualificato, nel rispetto delle vigenti normative impiantistiche, allo scopo di evitare danni a persone o cose. – Prima di qualsiasi intervento sull’apparecchio, rimuovere eventuali tensioni pericolose dall’apparecchio – Il costruttore non si assume responsabilità in merito alla sicurezza elettrica in caso di utilizzo improprio del dispositivo. – I prodotti descritti in questo documento sono suscettibili in qualsiasi momento di evoluzioni o di modifiche. Le descrizioni ed i dati a catalogo non possono pertanto avere alcun valore contrattuale. – Un interruttore o disgiuntore va compreso nell’impianto elettrico dell’edificio. Esso deve trovarsi in stretta vicinanza dell’apparecchio ed essere facilmente raggiungibile da parte dell’operatore. Deve essere marchiato come il dispositivo di interruzione dell’apparecchio: IEC/EN 61010-1 § 6.11. – Installare lo strumento in contenitore e/o quadro elettrico con grado di protezione minima IP51. – Pulire lo strumento con panno morbido, non usare prodotti abrasivi, detergenti liquidi o solventi. INTRODUCTION The DME D122MID is a single-phase active and reactive energy meter for direct connection, for currents up to 63A, equipped with a built-in M-BUS serial interface. The energy accuracy is compliant with standard EN50470-3 class B. Apart from energy metering, it can measure additional indications, for a total of 14 measurements that can be visualized on the backlighted LCD display. The DME D122MID has a standard 2U (36mm wide) modular housing and is supplied with sealable terminal blocks. INTRODUZIONE Il DME D122MID è un contatore di energia monofase per inserzione diretta, per correnti fino a 63A, dotato di interfaccia seriale M-BUS. La misurazione dell’energia è conforme alla norma EN50470-3 classe B. Oltre alla misurazione dell’energia, è in grado di fornire ulteriori indicazioni, per un totale di 14 misure, che possono essere visualizzati sull’ampio display LCD retroilluminato. Il DME D122MID ha un contenitore modulare standard di larghezza 2U (36 mm) ed è fornito di serie di coprimorsetti piombabili. DESCRIPTION – Modular DIN-rail housing, 2U (36mm wide). – Direct connection for currents up to 63A. – Active energy measure complies EN50470-3 class B. – LCD display with backlight. – Counter with 6+1 digits. – Button for measure selection and programming. – Total active and reactive energy meters. – Partial active and reactive energy meters, resettable. – Hour counter, total and partial. – Pulse LED for active energy consumption. – Indication of instantaneous consumption (active power). – M-BUS interface. DESCRIZIONE – Esecuzione modulare 2U (36mm) per guida DIN. – Inserzione diretta per correnti max 63A. – Misura energia attiva conforme a EN50470-3 classe B. – Display LCD retroilluminato. – Contatore con 6+1 cifre. – Tasto per la selezione delle misure e programmazione. – Contatori di energia attiva e reattiva totali. – Contatori di energia parziali azzerabili. – Contaore totale e parziale. – LED frontale a impulsi per energia attiva consumata. – Indicazione consumo istantaneo (potenza attiva). – Interfaccia M-BUS. SELECTION OF READINGS button it is possible to select the readings on the display, following the sequence in the table – Pressing briefly the reported below. – Each measure is indicated by the correspondent icon in the lower part of the display. – After one minute has elapsed after the last keystroke, the display moves automatically back to the total active energy screen. SELEZIONE MISURE è possibile selezionare le misure sul display dello strumento, secondo la – Premendo brevemente il pulsante sequenza indicata nella tabella riportata sotto. – A ciascuna selezione corrisponde un’icona nella parte bassa del display, con l’unità di misura selezionata. – Dopo un minuto senza premere il pulsante frontale, la misura si riposiziona sul contatore totale di energia attiva. Icon kWh kWh + Part kvarh kvarh + Part V A kW kvar PF Hz h∂ h + Part ∂ kW +d ∑ kW+d+▲∑ Measurement Total active energy Partial active energy Total reactive energy Partial reactive energy Voltage Current Active power Reactive power Power factor Frequency Hour counter (hhhhh.mm) Partial hour counter (hhhhh.mm) Average active power (15 min demand) Max avg. active power (max demand) ∂ These measurements are shown only enabling parameter P-08 ∑ These measurements are shown only enabling parameter P-09 Format 000000,0 000000,0 000000,0 000000,0 000,0 00,00 00,00 00,00 0,00 00,0 00000,00 00000,00 00,00 00,00 Icona kWh kWh + Part kvarh kvarh + Part V A kW kvar PF Hz h∂ h + Part ∂ kW +d ∑ kW+ d +▲∑ Misura Energia attiva totale Energia attiva parziale Energia reattiva totale Energia reattiva parziale Tensione Corrente Potenza attiva Potenza reattiva Fattore di potenza Frequenza Contaore (hhhhh.mm) Contaore parziale (hhhhh.mm) Potenza attiva media (demand su 15 min) Max potenza attiva media (max demand) ∂ Queste misure sono visibili solo abilitando il parametro P-08 ∑ Queste misure sono visibili solo abilitando il parametro P-09 Formato 000000,0 000000,0 000000,0 000000,0 000,0 00,00 00,00 00,00 0,00 00,0 00000,00 00000,00 00,00 00,00 METROLOGICAL LED – The red LED on the front emits 1000 pulses for every kWh of consumed Energy (that is, one pulse every Wh). – The pulsing frequency of the LED gives an immediate indication of the energy flowing in every moment. – The pulse duration, LED colour and intensity are compliant with the reference standards that define its utilization in order to verify the accuracy of the energy meter. LED METROLOGICO FRONTALE – Il LED rosso frontale emette 1000 impulsi per ogni kWh di energia consumata (ovvero 1 impulso per ogni Wh). – La frequenza di lampeggio del LED dà una immediata indicazione dell’entità della potenza richiesta in un determinato istante. – La durata del lampeggio, il colore e l’intensità del LED sono conformi alle norme che prescrivono il suo utilizzo ai fini di una verifica metrologica della accuratezza dell’energy meter. ENERGY FLOW INDICATION – When the device detects a flow of active energy to the load, it shows a rotating icon in the top-right part of the display. – When there is no active energy consumption or when the load draws less than the starting current the rotating icon disappears. INDICAZIONE FLUSSO DI ENERGIA – Quando lo strumento sta rilevando un flusso di energia verso il carico, il display visualizza nell’angolo in alto a destra una icona rotante. – Quando il carico non richiede energia attiva oppure quando la corrente assorbita è inferiore alla corrente di avviamento, l’icona rotante scompare. M-BUS – DME D122MID supports two addressing ways: primary address from 1 to 250 and secondary address from 00000000 to 99999999. – Baud rates: 300, 600, 1200, 2400, 4800, 9600, 19200, 38400 bps. – Refer to the electrical schemes at the end of the manual to connect DME D122MID to the bus in the proper way. – For reference tables and application notes go to www.lovatoelectric.com to get the M-BUS guide (instruction number: I513). M-BUS – DME D122MID supporta due modi di indirizzamento: indirizzo primario da 1 a 250 e indirizzo secondario da 00000000 a 99999999. – Velocità impostabili: 300, 600, 1200, 2400, 4800, 9600, 19200, 38400 bps. – Consultare gli schemi in fondo al manuale per un corretto collegamento del DME D122MID al bus. – Per le tabelle di riferimento e note implementative fare riferimento alla guida M-BUS presente sul sito www.lovatoelectric.com (numero istruzione: I513). PROGRAMMABLE LIMIT THRESHOLD – Through parameters from P-02 to P-07 it is possible to define the behaviour of a programmable limit threshold, whose status can be read from the communication protocol (see modbus addresses table). – The activation of the programmable limit threshold is shown on the display through the icon. – Note: During parameter setting (setup) the status of the programmable limit threshold is not updated. SOGLIA LIMITE PROGRAMMABILE – Tramite i parametri da P-02 a P-07 è possibile definire il comportamento di una soglia limite programmabile, il cui stato può essere letto tramite il protocollo di comunicazione (vedere tabella indirizzi modbus). – L’attivazione della soglia limite programmabile è visualizzata tramite l’icona sul display. – Nota: Durante l’impostazione dei parametri (Setup) lo stato della soglia limite programmabile non viene aggiornato. INCORRECT WIRING INDICATION – In case of incorrect wiring, when the device detects a reverse energy flow, the display shows the blinking code Err 3. – This error is caused by either reverse connection of current wires (terminals L↑ and L↓) or reverse voltage wiring (terminals N - L↑). – In these conditions, the energy is not counted. INDICAZIONE DI COLLEGAMENTO ERRATO • In caso di collegamento errato, quando l’apparecchio rileva un flusso di energia di direzione contraria, viene attivata l’indicazione lampeggiante Err 3. • Questo errore può essere provocato dalla inversione del collegamento della corrente (morsetti L↑ e L↓) oppure dalla inversione dei morsetti della tensione (N - L↑). • In queste condizioni l’energia non viene conteggiata. 1 31100384 I545 GB I 08 18 NAVIGATION WITH FRONT KEY – To move through menus, use the following rules: – A short click of the front key, indicated by , changes the current selection, shown on the display, with a new one (the next). – Pressing the key for a long time (> 3s), indicated with symbol , is used to confirm the displayed selection. – Symbol indicates when the user must wait for the display to move to a new selection. – To quit a menu, select the --ESC-- option. NAVIGAZIONE TRAMITE TASTO FRONTALE – Per muoversi fra i menu si usano le seguenti regole: – Una breve pressione del tasto frontale, che indicheremo con , viene utilizzata per cambiare la selezione attualmente visualizzata con una diversa, successiva. – Una pressione prolungata (> 3s), che indicheremo con , viene invece utilizzata per confermare la selezione visualizzata. – Il simbolo indica quando è necessario attendere perché il display proponga una nuova scelta. – Per uscire da un menu, selezionare --ESC--. ADVANCED FUNCTIONS – To access the advanced functions, use the following procedure: 1. Starting from any visualization screen, press . If the password protection is disabled (factory default, password = 0000), display jumps directly to point 4, otherwise it will show PASS to inform that the access code must be entered first. 2. Release the button. The display now waits for the password and indicates 0000. The single digits are flashing sequentially. Pressing while a digit is flashing, that digit is incremented. Waiting for some seconds, the selection moves to the next digit. After having entered the right password code, press to confirm. 3. If the entered password is wrong, the display shows PASS Er and goes back to normal visualization. If instead the code is correct, it proceeds to next point. FUNZIONI AVANZATE – Per accedere alle funzioni avanzate utilizzare la seguente procedura: 1. Partendo da una qualsiasi visualizzazione, premere . Se la protezione da password è disattivata (default di fabbrica, password = 0000) il display salta direttamente al punto 4, altrimenti indica PASS per evidenziare la necessità di inserire la password. 2. Rilasciare il tasto. Il display ora attende l’inserimento della password e indica 0000. Le singole cifre lampeggiano a rotazione. Premendo mentre una cifra sta lampeggiando, essa viene incrementata. Attendendo qualche secondo, la cifra successiva inizia a lampeggiare. Dopo avere inserito la password premere il tasto per confermare. 3. Se la password inserita non è corretta il display mostra PASS Er e torna alla visualizzazione normale. Se invece è corretta, si passa al punto successivo. 4. The display shows the first item of the following list. To move through the list, click • CLEAR P = clearing of partial energy meters • CLEAR H = clearing of partial hour counter (if enabled) • CLEAR D = clearing of max demand values (if enabled) • SETUP = parameters programming (setup) • INFO = revision and checksum of internal software • --ESC-- = returns to normal operation while the desired function is displayed. 5. To select a function, press 6. If the button is never pressed for 60 consecutive seconds, the display goes back automatically to normal operation. 4. Il display indica la prima delle scelte nella seguente lista. Per passare da una scelta alla successiva premere • CLEAR P = azzeramento contatori di energia parziali • CLEAR H = azzeramento contaore parziale (se abilitato) • CLEAR D = azzeramento max demand (se abilitato) • SETUP = programmazione parametri • INFO = revisione software e checksum interno • --ESC-- = ritorno al funzionamento normale mentre viene visualizzata la funzione desiderata. 5. Per selezionare una funzione premere 6. Se non vengono premuti tasti per 60 secondi l’apparecchio ritorna automaticamente al funzionamento normale. LOST OR FORGOTTEN PASSWORD If password is lost or forgotten, after three consecutive faulty attempts to enter the password, the display shows a 6-digit unlock code. Please contact LOVATO Electric customer service reporting this unlock code. The right password will be provided. The user is then free to change setting it as desired in the usual way (parameter P.01). PASSWORD DIMENTICATA O PERSA Se la password viene dimenticata o persa, dopo tre tentativi consecutivi di inserimento password non corretta, il display visualizza un codice di sblocco di 6 cifre. Contattare il customer service LOVATO Electric comunicando il codice di sblocco. Verrà restituita la password per l’accesso. L’utente è poi libero di re-impostarla a piacimento (tramite il parametro P.01). PARAMETER SETTING (SETUP) – While display is showing SETUP, press . – The display shows the first parameter code P-01. – Short-click to move to next parameters P-02, P-03…, etc use . – When the display indicates the code of the parameter that needs to be modified, press . • If it is a numeric parameter (password, thresholds, delays), the display shows its present value. The single digits are flashing sequentially. Pushing while a digit is flashing, that digit is incremented. Waiting some seconds, the selection moves to the next digit. • If instead, the parameter provides selection among different functions (e.g. output functions, measure etc), pressing , it is possible to sequentially select the desired one. • Confirm with to go back to parameter code selection. – After last parameter code, display shows --ESC--. Pressing button in this moment, parameters are saved and system goes back to normal operation. IMPOSTAZIONE PARAMETRI (SETUP) – Con il display che indica SETUP, premere . – Il display indica il codice del primo parametro P-01. – Per selezionare i parametri successivi P-02, P-03 … usare . – Quando il display indica il codice del parametro che si desidera modificare, premere . • Se si tratta di un parametro numerico (password, soglie, ritardi), il display indica il valore attuale dell’impostazione del parametro. Le singole cifre lampeggiano a rotazione. Premendo mentre una cifra sta lampeggiando, essa viene incrementata. Attendendo, comincia a lampeggiare la cifra successiva. • Se invece il parametro prevede la scelta fra diverse opzioni (funzione uscita, misura) premendo si può selezionare a rotazione la funzione voluta. • Confermando con si può tornare alla selezione parametri. – Dopo l’ultimo codice parametro il display visualizza --ESC--. Premendo il tasto in questo momento, i parametri vengono salvati e si torna al funzionamento normale. 2 TABELLA PARAMETRI DI SETUP Code P-01 P-02 P-03 Description Password Programmable limit threshold enable Threshold measure Default 0000 OFF kW P-04 P-05 P-06 P-07 P-08 P-09 P-20 P-21 P-22 P-23 ON threshold ON delay OFF threshold OFF delay Hour counter enable Enable demand measures Primary address Secondary address HIGH Secondary address LOW Serial speed 100.00 5s 50.00 5s OFF OFF 001 Serial n. Serial n. 2400 Range 0000 - 9999 OFF - THR 01=kW - 02=kvar - 03=V 04=A - 05=Hz - 06=kWh Part 07=h Part – 08 kW demand 0.00 – 999.99 0 – 9999 sec. 0.00 – 999.99 0 – 9999 sec. OFF-ON-THR OFF-ON 001-250 0000-9999 0000-9999 300 600 1200 2400 4800 9600 19200 38400 Codice P-01 P-02 P-03 Descrizione Password Abilitazione soglia limite programmabile Misura per soglia Default 0000 OFF kW P-04 P-05 P-06 P-07 P-08 P-09 P-20 P-21 P-22 P-23 Soglia ON Ritardo soglia ON Soglia OFF Ritardo soglia OFF Abilitazione contaore Abilitazione misure demand Primary address Secondary address HIGH Secondary address LOW Serial speed 100,00 5 sec. 50,00 5 sec. OFF OFF 001 Serial n. Serial n. 2400 Range 0000 - 9999 OFF - THR 01=kW - 02=kvar - 03=V 04=A - 05=Hz - 06=kWh Part 07=h Part – 08 kW demand 0,00 – 999,99 0 – 9999 sec. 0,00 – 999,99 0 – 9999 sec. OFF-ON-THR OFF-ON 001-250 0000-9999 0000-9999 300 600 1200 2400 4800 9600 19200 38400 P-01 – If set to 0000 (default) the password protection is disabled. P-02 – Defines the function of the programmable limit threshold: OFF – Programmable threshold disabled. THR – The programmable threshold is activated by a maximum or minimum limit, depending on values programmed in P-04 and P-06. If P-04 > P-06, then the limit threshold activates when the measure defined by P-03 is higher than P-04, end de-activates when its value becomes less than P-06 (maximum limit with hysteresis). If P-04 < P-06, then the limit threshold activates when the measure defined by P-03 is lower than P-04, end activates when its value becomes higher than P-06 (minimum limit with hysteresis). P-03 – Selection of measure to compare with thresholds. P-04 and P-05 – Threshold and delay for output activation. Note: The measurements are updated every 1 second, that means that the variability of this delay is in the range from 0 to + 1 second. P-06 and P-07 – Threshold and delay for output de-activation. P-08 – Defines the hor counter operation: OFF – hour counter disabled. It is not shown on the display. ON – The hour counter is incremented as long as the energy meter is supplied. THR – The hour counter is incremented as long as the threshold defined with previous parameter ( P-02, P-03, P-04 e P-05) is active. P-09 – Enable of calculation and visualization of active energy demand and max demand. P-20 – Primary address. P-21 – Secondary address, first half (4 digits). P-22 – Secondary address, second half (4 digits). The complete secondary address can be got by concatenating the content of parameter P-21 with the one of parameter P-22. Example: secondary address 12345678, set P-21=1234 and P-22=5678. P-23 – Baud rate. P-01 – Se impostato a 0000 (default) la protezione da password è disabilitata. P-02 – Definisce la funzione della soglia limite programmabile: OFF – Soglia programmabile disabilitata. THR – La soglia programmabile è attivata massima oppure di minima, a seconda dei valori impostati in P-04 e P-06. Se P-04 > P-06, allora la soglia limite si attiva con la misura di P-03 > P-04, e si disattiva quando ritorna ad essere < P-06 (funzione di soglia massima con isteresi). Se P-04 < P-06, allora la soglia limite si attiva con la misura di P-03 < P-04, e si disattiva quando ritorna ad essere > P-06 (funzione di soglia minima con isteresi). P-03 – Selezione misura alla quale vengono applicate le soglie. P-04 e P-05 – Soglia e relativo ritardo per attivazione uscita. Nota: le misure vengono aggiornate ed integrate 1 volta al secondo, quindi questo ritardo ha una variabilità da 0 a + 1 secondo. P-06 e P-07 – Come sopra, per disattivazione uscita. P-08 – Definisce il funzionamento del contaore: OFF – Contaore disabilitato, non viene visualizzato. ON – Il contaore si incrementa fintanto che l’energy meter è alimentato. THR – Il contaore si incrementa fintanto che la soglia definita con i parametri precedenti ( P-02, P-03, P-04 e P-05) è attivata. P-09 – Abilitazione misura e visualizzazione potenza attiva integrata attuale e massima (max demand). P-20 – Indirizzo primario. P-21 – Indirizzo secondario, prime 4 cifre. P-22 – Indirizzo secondario, ultime 4 cifre. L’indirizzo secondario completo si ottiene concatenando il contenuto del parametro P-21 con quello del parametro P-22. Esempio: indirizzo secondario 12345678, occorre impostare P-21=1234 e P-22=5678. P-23 – Velocità. MECHANICAL DIMENSIONS AND WIRING DIAGRAMS DIMENSIONI MECCANICHE E SCHEMI DI COLLEGAMENTO N N M1 M2 N Energy meter 92.5 90 DME D121 44.7 31100384 I545 GB I 08 18 SETUP PARAMETER TABLE LINE LOAD 220...240V 50/60Hz 100...120V 50/60Hz 0.5-10 (63)A CI. 1 1000 Imp/kWh L 35.8 L 43.7 5 L 63 M-BUS CONNECTION L CONNESSIONE M-BUS Max 1000m Max 25Ohm - 180pF M1 M2 M1M2 M1 M2 M1M2 M-Bus M-Bus DME D122MID n°250 * DME D122MID n°1 M1 M2 M-Bus M-Bus Master NOTE: The number of connected devices depends on the Master unit load capacity 3 31100384 GB I TECHNICAL CHARACTERISTICS CARATTERISTICHE TECNICHE I545 GB I 08 18 Voltage Tensione Nominal voltage Us 230V~ Tensione nominale Us 230V~ Operating voltage range 187 – 264V~ Limiti di funzionamento 187 - 264V~ Nominal frequency 50Hz Frequenza nominale 50Hz Operating frequency range 45 - 66Hz Limiti di funzionamento 45 - 66Hz Power consumption/dissipation 1VA / 0.4W Potenza assorbita/dissipata 1VA / 0,4W Current Corrente Minimum current (Imin) 0.5A Corrente minima (Imin) 0,5A Transition current (Itr) 1A Corrente di transizione (Itr) 1A Reference current (Iref - Ib) 10A Corrente di riferimento (Iref - Ib) 10A Max current (Imax) 63A Corrente massima (Imax) 63A Start current (Ist) 40 mA Corrente di start (Ist) 40 mA Accuracy Active energy (EN50470-3) Accuratezza Class B LED pulse Energia attiva (EN50470-3) Classe B Impulso LED Integration constant 1000 pulses / kWh Costante di integrazione 1000 imp / kWh Pulse lenght 30ms Durata impulso 30ms M-BUS (Slave) M-BUS (Slave) Bus length According to M-Bus specification Lunghezza bus Secondo specifiche M-Bus Speed Programmable 300-38400 Baud Velocità Programmabile 300-38400 Baud Typical current consumption ≤3mA (2 unit load) Ambient operating conditions Assorbimento tipico ≤3mA (2 unit load) Condizioni ambientali di funzionamento Mounting Indoor use only Installazione Solo per uso interno Operating temperature -25 - +55°C Temperatura d’impiego -25 - +55°C Storage temperature -25 - +70°C Temperatura di stoccaggio -25 - +70°C Relative humidity <80% non-condensing (IEC/EN 60068-2-78) Umidità relativa <80% non condensante (IEC/EN 60068-2-78) Maximum pollution degree 2 Grado di inquinamento ambiente massimo 2 Overvoltage category III Categoria dì sovratensione III Altitude ≤2000m Climatic sequence Z/ABDM (IEC/EN 60068-2-61) Sequenza climatica Z/ABDM (IEC/EN 60068-2-61) Shock resistance 10g (IEC/EN 60068-2-27) Resistenza agli urti 10g (IEC/EN 60068-2-27) Altitudine ≤2000m Vibration resistance 0.7g (IEC/EN 60068-2-6) Resistenza alle vibrazioni 0,7g (IEC/EN 60068-2-6) Mechanical environment Class M1 Ambiente meccanico Classe M1 Electromagnetic environment Class E1 Ambiente elettromagnetico Classe E1 Insulation voltage Tensione di isolamento Rated insulation voltage Ui 250V~ Tensione nominale d’isolamento Ui 250V~ Rated impulse withstand voltage Uimp 6kV Tensione nominale di tenuta a impulso Uimp 6kV Power frequency withstand voltage 4kV Tensione di tenuta a frequenza d’esercizio 4kV Supply / measure connections Connessioni circuito alimentazione / misura Terminal type Screw (fixed) Tipo di morsetti A vite (fissi) Number of terminals 3 for Aux supply / measure N° morsetti 3 per alimentazione / misura Cable cross section (min… max) 2.5 - 16 mm2 Sezione conduttori (min e max) 2,5 - 16 mm2 Tightening torque 2 - 2.2 Nm Coppia di serraggio morsetti 2 - 2,2 Nm M-BUS interface connections Connessioni interfaccia M-BUS Type of terminals Screw (fixed) Tipo di morsetti A vite (fissi) Number of terminals 2 N° morsetti 2 Conductor cross section (min… max) 0.5…4 mm2 (20…11 AWG) Sezione conduttori (min…max) 0,5…4 mm2 (20…11 AWG) Tightening torque 1.3Nm (11.5lbin) Coppia di serraggio morsetti 1,3Nm (11,5lbin) Housing Contenitore Version 2 modules (DIN 43880) Esecuzione 2 moduli (DIN 43880) Mounting 35mm DIN rail (EN 60715) or by screw using extractible clips Montaggio Guida 35mm (EN 60715) o a vite a mezzo clip estraibili Polyamide RAL 7035 Materiale Poliammide RAL 7035 Material Degree of protection IP40 on front ∂ Weight 148g Certifications and compliance Grado di protezione IP40 sul fronte ∂ Peso 148g Omologazioni e conformità Certifications EAC Omologazioni EAC Comply with standards EN50470-1, EN50470-3, TR50579 Conformi alle norme EN50470-1, EN50470-3, TR50579 ∂ To comply with the protection requirements the meter must be mounted in a class IP51 enclosure or better. (IEC/EN 60529). ∂ Per garantire la protezione richiesta, lo strumento deve essere installato in contenitore con grado di protezione minimo IP51 (IEC/EN60529). 4 ">
/
Download
Just a friendly reminder. You can view the document right here. But most importantly, our AI has already read it. It can explain complex things in simple terms, answer your questions in any language, and help you quickly navigate even the longest or most compilcated documents.
Advertisement