Maximum Controls Max Megatron 1400HP Installation And Owner's Manual

Add to My manuals
52 Pages

advertisement

Maximum Controls Max Megatron 1400HP Installation And Owner's Manual | Manualzz
www.max.us.com
CONFORMS TO UL STD 325
UL CLASS - I, II, III, IV
SAFETY SENSORS REQUIRED FOR UL 325 2016
CERTIFIED TO CAN/CSA STD
C22.2 NO. 247
T
S
A
/F
14
0
0
0
0
H
2
P
/2
0
0
14
Residential / Commercial
Brushless DC
Swing Gate Operators
Made in USA
4009963
MAX MEGATRON
1400 / 1400HP / 2200 / FAST
Single or Bi-Parting Gates
Version 10
Single or Bi-Parting Gates
Single or Bi-Parting Gates
Bi-Parting Gates ONLY
Installation and Owners Manual
Table of contents
MAX Megatron Specifications
Important Safety Information
UL 325 Model Classifications
UL 325 Required Entrapment Protection
UL 325 Compliant Installation Requirements
Intended Use of Swing Gate Operator
2
2
3
3
4
5
Installation
Gate Operator Position
Recommended Gate Operator Layout
Layout and Arm Height of 1400/2200/FAST or 1400HP
Dual Gate Operators
Arm Position Options
Arm Connection to Gate
Optional Remote Power Supply Kit - MAX Magic Box
Compact Installation ONLY
Solar Optional
Entrapment Protection
In-Ground Loops
Install Warning Signs
6
7
8
9
10
10
11
12
12
13
14
15
Adjustments
Open and Close Limits
Release Handle Clamp
Reverse Sensor (ERD)
35
36
37
Maintenance
Qualified gate operator technician
End user/Home owner
MAX Megatron Primary Wiring Schematics
MAX Megatron Secondary Wiring Schematics
Manual Release
Electronic Gate Open / Close - Optional
Audible Alarm
Replacement Parts List
Warranty
38
38
39
40
41
42
42
43
44
Megatron options / unique features
Gate Tamper Feature
Gate Disable Feature
Event History Download
45
46
46
Wiring operator
Gate Operator System Overview
Entrapment Protection Wiring
Input AC Power
Optional Remote Power Supply Kit - MAX Magic Box
Solar Power Connection - Optional
Secondary Operator to Matrix 1
Turn ON / OFF Operator Power
15-16
17-18
19
20
21
22
23
matrix 1
Matrix 1 Overview
Wiring Overview
Primary Gate - Open Left / Open Right
Close Timer
Selectable Gate Speed Control
Battery Back-Up Mode
Anti-Tailgate
Single Pass Anti-Tailgate
Radio Receiver
Radio Safety Pause
Gate in Motion Alarms
OBD Port Black Box
Maglock
Loop Detectors
In-Ground Loop Connection
ID Plug
Gate Tamper
UL Entrapment LEDs
Emergency Vehicle / Max Open Inputs
Gate Disable
Partial Open
UL Alarm / Shut-Off Alarm
Gate Status Monitoring
OPEN / STOP / CLOSE Connection
External Alarm Reset Button (Shut-Off Alarm)
CLOSING Photocell Connection
Gate Operators Communication LEDs
24V Power for Matrix 1
Battery in Use LED
Motor Motion LEDs
External OPEN/CLOSE Key Switch - Optional
24
25
26
26
26
26
27
27
28
28
28
28
29
29
29
30
30
30
30
31
31
32
32
32
32
32
33
33
33
33
34
© 2015 Maximum Controls LLC.
All rights reserved. No part of this manual may be reproduced in any
means: graphics, electronics or mechanical, including photocopying
without the expressed written permission of the publisher. Materials
components and specifications are subject to change without notice.
1
max megatron specifications
25.2”
29.9”
26.6”
UL 325 Class of Operation - Class I, II, III, IV
1400HP
Gate Type - Vehicular Swing Gate
(High Profile)
Max Gate Weight / Length:
- MAX Megatron 1400/1400HP - 1400lbs @ 15 ft or 1200 lbs @ 20 ft
- MAX Megatron 2200 - 2200lbs @ 15 ft or 1500 lbs @ 20 ft
- MAX Megatron FAST - 1600lbs @ 12 ft gate per operator
1400HP
24.5”
NOTE: The MAX Megatron FAST is ONLY available for installation on bi-parting gates (dual operators).
A single gate operator CANNOT be used.
90° Opening Time:
- MAX Megatron 1400/1400HP/2200 - 16 selectable speeds from approximately
11.5 sec to 20 sec depending on the weight and length of the gate.
- MAX Megatron FAST - 16 selectable speeds from approximately
6 sec to 14 sec depending on the weight and length of the dual gates.
Cycles per Hour AC Input Power - Continuous
Battery Back-Up Cycles (BC-7 Battery Module-7 Amp/Hr Batteries fully charged):
- Approximately 450 cycles
1400HP
16.8”
24.5”
NOTE: The number of gate cycles using ONLY battery back-up power will vary depending on the
weight of the gate, the gate length, the operating condition of the gate hardware, temperature and
the amount of charge the batteries have at the beginning of the battery power only operation.
Input AC Power - Switchable: 115VAC or 230VAC single phase
Motor - 24VDC Brushless (equivalent to 1 HP AC motor)
Operating Temperature: -4°F to 158°F (-20°C to 70°C)
Entrapment Protection:
- UL 325 Type A Inherent (ERD sensor)
- Inputs for NORMALLY CLOSED (N.C.)
UL 325 Type B1 (photo cell)
and Type B2 (sensing edge)
18.3”
17”
18.5”
21.3”
important safety information
WARNING – To reduce the risk of injury or death:
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. Never let children operate or play with gate controls. Keep the remote control away from children.
3. Always keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE.
4. Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or stop when an object activates the
non-contact sensors. After adjusting the force or the limit of travel, retest the gate operator. Failure to adjust and retest the
gate operator properly can increase the risk of injury or death.
5. Use the emergency release only when the gate is not moving.
6. KEEP GATES PROPERLY MAINTAINED. Read the owner’s manual. Have a qualified service person make repairs to gate
hardware.
7. The entrance is for vehicles only. Pedestrians must use separate entrance.
8. SAVE THESE INSTRUCTIONS
2
ul 325 model classifications
AUTHORIZED
PERSONNEL
ONLY
CLASS I
CLASS III
Residential Vehicular Gate Operator - A vehicular gate operator
(opener or system) intended for use in a home of one to four
single family dwellings, or a garage or parking area associated
therewith.
Industrial/Limited Access Vehicular Gate Operator - A
vehicular gate operator (opener or system) intended for uses
in an industrial location, loading dock area or other location
not intended to service the general public.
SECURITY
CLASS II
CLASS IV
Commercial/General Access Vehicular Gate Operator - A
vehicular gate operator (opener or system) intended for use in
a commercial location or building such as a multi-family
housing unit (five or more single family units) hotel, garages,
retail store or other building servicing the general public.
Restricted Access Vehicular Gate Operator - A vehicular gate
operator (opener or system) intended for use in a guarded
industrial location or buildings such as airport security area or
other restricted access locations not servicing the general
public, in which unauthorized access is prevented via
supervision by security personnel.
ul 325 required entrapment protection
This vehicular gate operator must be installed with at least two independent entrapment protection means as specified in the table and
definitions below.
The same type of device shall not be used for both entrapment protection means. Use of a single device to cover both the opening and
closing directions is in accordance with the requirement, however, a single device is not required to cover both directions. This operator
has been provided with type A entrapment protection. The installer is required to install additional entrapment protection devices in each
entrapment area.
Gate Type
Class I & II
Class III & IV
Swing Gate
A, B1*, B2*, C, D
A, B1*, B2*, C, D, E
Slide Gate
A, B1*, B2*, D
A, B1*, B2*, D, E
A - Inherent entrapment protection system.
C - Inherent adjustable clutch or pressure relief device.
B1 - Provision for connection of a non-contact sensor
(photoelectric sensor or the equivalent).
D - Provision for connection of an actuating device
requiring continuous pressure to maintain opening
or closing motion of the gate.
B2 - Provision for connection of a contact sensor
(edge device or the equivalent).
E - An audio alarm.
* B1 and B2 means of entrapment protection must be MONITORED.
3
ul 325 compliant
installation requirements
A Install the gate operator only when:
1 The operator is appropriate for the construction of the gate and the usage Class of the gate,
2 All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 6 feet (1.83 m) above the
ground to prevent a 2-1/4 inch (57.2 mm) diameter sphere from passing through the openings anywhere in the gate, and in that
portion of the adjacent fence that the gate covers in the open position,
3 All exposed pinch points are eliminated or guarded, and
4 Guarding is supplied for exposed rollers.
B The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening. The
pedestrian access opening shall be designed to promote pedestrian usage. Locate the gate such that persons will not come in contact with
the vehicular gate during the entire path of travel of the vehicular gate.
C The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and
closing to reduce the risk of entrapment. Swinging gates shall not open into public access areas.
D The gate must be properly installed and work freely in both directions prior to the installation of the gate operator. Do not over-tighten the
operator clutch or pressure relief valve to compensate for a damaged gate.
E For gate operators utilizing Type D protection:
1 The gate operator controls must be placed so that the user has full view of the gate area when the gate is moving,
2 A gate operator shall additionally be provided with a placard that is marked in letters at least 1/4-in (6.4-mm) high with the word
“WARNING” and the following statement or the equivalent: “Moving Gate Has Potential of Inflicting Injury or Death - Do Not Start
Gate Unless Path is Clear”.
3 An automatic closing device (such as a timer, loop sensor, or similar device) shall not be employed, and
4 No other activation device shall be connected.
F Controls intended for user activation must be located at least six feet (6’) away from any moving part of the gate and where the user is
prevented from reaching over, under, around or through the gate to operate the controls. Outdoor or easily accessible controls shall have a
security feature to prevent unauthorized use.
G The Stop and/or Reset button must be located in the line-of-sight of the gate. Activation of the reset control shall not cause the operator to start.
H A minimum of two (2) WARNING SIGNS shall be installed, one on each side of the gate where easily visible.
I For gate operators utilizing a non-contact sensor:
1 See instructions on the placement of non-contact sensors for each Type of application,
2 Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle, trips the sensor while the gate is still moving, and
3 One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable
by a moving gate or barrier.
J For a gate operator utilizing a contact sensor:
1 One or more contact sensors shall be located where the risk of entrapment or obstruction exists, such as at the leading edge, trailing
edge, and post mounted both inside and outside of a vehicular horizontal slide gate.
2 One or more contact sensors shall be located at the bottom edge of a vehicular vertical lift gate.
3 One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate.
4 A hardwired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate
operator is not subjected to mechanical damage.
5 A wireless device such as one that transmits radio frequency (RF) signals to the gate operator for entrapment protection functions
shall be located where the transmission of the signals are not obstructed or impeded by building structures natural landscaping or
similar obstruction. A wireless device shall function under the intended end-use conditions.
6 One or more contact sensors shall be located on the inside and outside leading edge of a swing gate. Additionally, if the bottom edge
of a swing gate is greater than 6 inches (152 mm) above the ground at any point in its arc of travel, one or more contact sensors shall
be located on the bottom edge.
7 One or more contact sensors shall be located at the bottom edge of a vertical barrier (arm).
4
intended use of
swing gate operator
The operator is intended for use on a VEHICULAR slide gate ONLY. It is intended to be used WITH appropriate entrapment
protection safety devices and in-ground vehicle loop detection system. This operator has a inherent entrapment protection
system and requires additional external monitored entrapment protection devices (Non-contact Photocells or contact sensing
edges) for each entrapment area prior to gate operation.
Opening Direction Photocell: Helps
guard against the opening gate from
entrapment.
Opening/Closing Direction 10K Sensing Edge: Helps
protect against entrapment in hinge area.
Closing Direction Photocell: Helps protect the gate
operator from accidentally closing on vehicles in the gate’s
closing path and entrapment.
Warning Signs: Should be installed
on both sides of gate area and
easily visible.
M
Seovin
KE rio g
withEP CL us Ga
te
Do out prEAR! In
C
in not ior wa Gajury an
th let
te
Th e ga child rning may o Ca
r
Peis en te ar ren .
mov D us
de tra ea. op
e at ea e
str nc
er
th
ian e is
ate
an
s m fo
y tim
the
us r ve
ga
e
t us hic
te
e se les
or
pla
pa only.
y
rate
en
tra
nc
e.
ent
m
p
a
a
ntr Are
E
In-Ground Loops:
Help protect the gate
operator from accidentally
opening and/or closing on
vehicles in the gate’s path.
En
tra
pm
en
tA
rea
Opening/Closing Direction 10K Sensing Edge: Helps
protect the gate operator from accidentally opening
and/or closing on vehicles in the gate’s path.
(Wireless Option)
Pedestrians MUST use a separate entrance.
The gate operator IS NOT intended to be
used on a PEDESTRIAN gate.
Bottom of Gate
NOTE: sensors
MUST be
MONITORED
and NORMALLY
CLOSED (N.C.)
6” or More OPENING/CLOSING direction Gate Protection 10K Sensing Edge on Bottom of Gate: If the bottom of
gate is 6 inches or higher above the ground, then a sensing edge should be installed for safety.
5
installation
Read and understand this entire manual before installation. Check with the local building department prior to installing this gate
operator to comply with local building code requirements. The gate must be installed in a location so that enough clearance is
supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates
should not open into public access areas.
Gate Operator position
The gate must be properly installed and work freely in both directions prior to installation of the gate operator.
Closed Position
Gate Bracket Pivot Point
Hinge Pivot Point
Illustrations not to scale
A
Lock
Lon
ed P
g Ar
m
Measurement Guidelines
A Should be at least 1/4 the gate length.
B
Arm
Pivot
Point
ositi
on
D
Concrete Pad
15” Min
8”
Longer
than “E”
Sho
m
NOTE: Uphill or heavy gates should be at least
1/3 gate length.
5
JOG
JOG
LEFT RIGHT
4
LED ON
POWER
IN
POWER/SOLAR
IN
Shorter
than “D”
MATRIX
BATTERY
IN
1
TO MOTOR
CONTROLLER
BATTERY
BACK-UP MODE
PRIMARY
GATE
LEAVE
CLOSED
MADE
in
LEAVE
OPEN
USA
AUTOMATIC
ON
OPEN
LEFT
OPEN
1 TIME
OPEN/CLOSE
ANTI
TAILGATE
EXIT
POWER
Limit SW Edge PhotoCell
EXIT
BATTERY
PACK
MAGLOCK
DELAY
OPEN
RIGHT
OFF
1.5Sec
2Sec
MAG
LOCK
COM
NC
CONTROLS
CENTER
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
OFF
CENTER
PHOTOCELL
UL
SAFETY
MIN
OFF
CLOSE
ENTRAP
PARTIAL
OPEN
MOTOR
GND
EDGE
1
2
OBD PORT
BLACK BOX
24VDC
OPEN
MAX
GATE
STOP
CLOSE
REVERSE
SPEED
MIN
ALARM 12V
ALARM RET
RESET
GND
SENSITIVITY
MOTOR
OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
OPEN
COM
CLOSE
GATE
STATUS
BATTERY
IN USE
POWER
24V
GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCEL
GND
SEC
GATE
(+)
GND
(-)
FIRE DEPT
GND
MAX OPEN
GND
LIMIT
SWITCH
ON-LINE
MOTOR
ON-LINE
PRIMARY
GATE
(+)
GND
(-)
RADIO GND
GND
RADIO SIG.
30”
ID PLUG
ERROR
MOTION
UL
POSITION
RECORDER
12VDC
EDGE
MAX
TIMER
ID
PLUG
www.max.us.com
Made in USA
8”
and in the straight “locked” position when CLOSED.
12”
Maximum arm length is 71 inches.
24”
Open Position
Outside Property
Inside Property
5
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
OPEN
LIMIT
ERD
JOG
JOG
LEFT RIGHT
Sensitivity
Motor
OverLoad
CLOSED
LIMIT
2” Gate Frame
2” Min
od
MC-200
1
2
MAX
12
16
13 14 15
Motor Controller
MATRIX
ON-LINE Edge UL Entrap
3
ERD
Operator
Pivot
Point
14”
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
OPEN
LIMIT
ERD
Sensitivity
Motor
OverLoad
CLOSED
LIMIT
E
B 15” minimum for open gate clearance (2” thick gate).
C Distance “A” minus 17 inches (A - 17 = C).
D & E Arm should be 90° from gate when OPEN
Ho
C
rt Ar
4
MC-200
1
2
MAX
12
16
13 14 15
LED ON
BATTERY
IN
1
POWER
IN
TO MOTOR
CONTROLLER
BATTERY
BACK-UP MODE
PRIMARY
GATE
LEAVE
CLOSED
MADE
in
LEAVE
OPEN
USA
AUTOMATIC
ON
OPEN
LEFT
OPEN
1 TIME
OPEN/CLOSE
ANTI
TAILGATE
EXIT
POWER
Limit SW Edge PhotoCell
POWER/SOLAR
IN
MATRIX
Motor Controller
MATRIX
ON-LINE Edge UL Entrap
3
ERD
EXIT
BATTERY
PACK
MAGLOCK
DELAY
OPEN
RIGHT
OFF
1.5Sec
2Sec
MAG
LOCK
COM
NC
CONTROLS
CENTER
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
OFF
CENTER
PHOTOCELL
UL
SAFETY
MIN
OFF
CLOSE
ENTRAP
PARTIAL
OPEN
MOTOR
GND
EDGE
1
2
ID PLUG
ERROR
MOTION
UL
POSITION
RECORDER
12VDC
EDGE
MAX
TIMER
ID
PLUG
OBD PORT
BLACK BOX
24VDC
STOP
OPEN
MAX
GATE
CLOSE
REVERSE
SPEED
MIN
ALARM 12V
ALARM RET
RESET
GND
SENSITIVITY
MOTOR
OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
OPEN
COM
CLOSE
GATE
STATUS
BATTERY
IN USE
POWER
24V
GND
SEC
GATE
OPEN
STOP
CLOSE
COM
GATE DISABLE
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCEL
GND
FIRE DEPT
GND
MAX OPEN
GND
MOTOR
ON-LINE
(+)
GND
(-)
RADIO SIG.
LIMIT
SWITCH
ON-LINE
PRIMARY
GATE
(+)
GND
(-)
RADIO GND
GND
www.max.us.com
DO NOT allow arm to touch
hood in gate’s OPEN position.
TOO MUCH STRESS is put on
the arm in this position during
gate operation.
6
Preferred arm position
is 90° from open gate.
See page 10 for arm
position options and
connection to gate.
NOTE: If dimension between OPEN gate
and wall is 20” to 32” then compact
installation is necessary, see page 12.
Wall
Made in USA
installation
recommended Gate Operator layout
Use for VEHICULAR traffic ONLY. Pedestrians MUST use a separate
entrance. Install appropriate entrapment protection safety devices
for the OPENING direction and CLOSING direction of gate cycling.
Install in-ground SAFETY and CENTER loops. Install a GROUNDING
ROD within 10 ft of operator. An “Optional” EXIT loop can be
installed if desired.
GA Run
TE wi
OP ring
E
10
t
Mo K S RATO o
R.
un ens
t o in
g
n
and end o Edge
hin f ga
ge te
are
GA Run
a.
TE wi
r
OP ing
ER to
AT
OR
.
NOTE: ONE Entrapment protection
sensor MUST installed or operator
will NOT function. It MUST be
MONITORED and NORMALLY
CLOSED (N.C.)
Ma
xM
ini
Ed
ge
ERD
ity
sitiv
Sen
D
ER
tor ad
Mo Lo
er
Ov
5
4 3
12
13
14
15
16
LED
Su
pp
G
JO FT
LE
MA
X
ON
IX
Jo
Jo g
g LT
RT
Ed GN
Ed ge D
Ph ge 1
Ce oto 2
ll
G T
JO GH
RI
MA
TR
1
Pho
OFF
ort
0
NT
MAT
BOARIX
RD
CEN
TER
Ba
r
MAG
DELLOCK
AY
1.5Se
c
RO
LS
2Sec
MAG
LOC
K
SAF
ETY
COM
NC
OFF MAX
TIM
ER
ALARM
LIMIT
SWITC
H
PART
OPENIAL
GAT
TAM E
PER
Tam
PACK Y
BATTER
S
SE
ll
toCe
OPEN
RIGH
T
E CO
MIN
CLO
e
Edg
OP
EN
/CL
OS
EXIT
SAFET
Y
ID
PLU
G
-20
OPEN
LEFT
RS-485 (+) RS-485 (-) GND PWR 24V -
CENT
ER
UL
E
OFF
MC
er
oll
ntr
Co
tor WER
Mo ap PO
Entr
t SW
ON
e
Limi
ANT
TAIL I
GAT
EXIT
PRIM
GATARY
E
OPEN
1 TIME
1
Edg
ED
AU
TO
MA
TIC
2
RIX
ON-
BACBATTER
K-U Y
P MOD
LEAVE LEAVE
E
OPEN CLOS
in USA
MAT LINE
MADE
per
NO
COM
Tam GND
per
IN
INPUTR
MOTO
UL
GAT
STA E
TUS
SEC
GATE
BAT
TER
IN Y
USE
24V
GND
(+)
GND
(-)
Se
cu
to re ga
six conc te o
(6) rete per
1/2 pa ator
d
sle ” x 3” with
eve (m
anc in)
ho
rs.
ction
d prote
the
inue with
.
contonly
fuse
: For ce g of
pasre les
ne
NING repla
fire, ratin pour cont le
WARnst and
fusib
:
un es
ENT ction
agaie type
er stiqu
SEMla prote
sam
utilis
RTISettre e,caractéri
endiet
ALA
ALA RM
RM 12V
RET
RES
ET
GND
AVEprom
d’inc
com es type
es
risqu
mêm s.
de inale
nom
OPE
N
COM
CLO
SE
OPEN
STOP
CLOSE
COM
GATE DISABLE
RADIO SIG.
FIRE DEPT
GND
MAX OPEN
GND
RADIO GND
SENS
ITIVIT
MOTO
Y
R OVER
NO
LOAD
LIMIT
CLAM
SWIT
P SLIPPCH
ING/
ELL
EDG
E1
EDG
E2
ID
PLU
ERR G
OR
CLO
SE
REVE
RSE
PRIM ON-L R
INE
GATEARY
(+)
GND
(-)
STRIKE
GND
KEYPAD
/ RDR
GND
PHOTOCELL
GND
ENTR
AP
STO
P
ED
LIMIT
SWIT
ON-L CH
INE
MOTO
Pow
E SPE
MAX
R
o
ati
str
Illu
ION
GAT
PHO
TOC
UL
MOT
OPE
N
MAX
MIN
t
ot
nn
MOT
OR
POS
REC ITIO
ORD N
ER
OBD
BLAC POR
K BOXT
TO
C
C
er
In
GND
24VD
GND
le
ca
os
MO
12VD
POW
ER
p
7 AmE
x
ma
FUS On
3A
ER
VAC
POW
115
Off
Batt
ery
E
Volt
1/2
age
F
ON/O
BatteFF
ry Repla
Battece
ry
MA
X BC
Batte
ry
TEST
Batte
ry
Modu
-7
le
Batte
ry
Error IN
CL
PhOSIN
21 otoceG
” H ll
igh Bea
m
1/2
Su
Gr
Ro ound
d
pp
m
ll Bea
e
toc
G Pho
”
10
12
t
ui
nd a 5”
Co Are 8.
x
5”
5.
”
12
5”
ps
E
o
Lo
OP
C
S
”
24n
i
M
nte
Sa
fet
e
w
Po
oop
rL
oo
p
)
red
qui
l
cel
Ce
In
e
r (R
G
NIN
oto
Ph
r
yL
t
afe
m
Fro
5.
nd
ou
-Gr
tA
npu
6” ove
Ab und
Gro
”
2
Pa 4”x 3
d
0”
am
Be ght
i
He st
Ju ve
o
Ab te
Gaator
er
Op
Ba
ING
OS ll
CLotoce
Ph
PENIN
O
ort
I
yL
oo
p
E
(Op xit L
tio oop
na
l)
7
installation
layout and arm height of 1400/2200/FAST or 1400hp
The gate must be properly installed and work freely in both directions prior to the installation of the gate operator.
See “Gate Operator Position” on page 6 for operator position and “Arm Connection to Gate” on page 10.
Conduit Guidelines and Suggestions (See page 7)
• REQUIRED - AC input power wire.
• REQUIRED - Entrapment protection (photocell and/or sensing edge). See page 13.
• Normally open photocell. See page 13.
• In-ground loop wires. See page 14.
Illustration not to scale
Arm MUST be installed level.
Support Bar: See below
Secure gate operator
to concrete pad with
six (6) 1/2” x 3”
(min) sleeve anchors.
1/2
MATRIX 1
PRIMARY
GATE
BATTERY
BACK-UP MODE
LEAVE
CLOSED
LEAVE
OPEN
MADE in USA
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
MATRIX
BOARD
EXIT
ON
EXIT
CENTER
GATE
TAMPER
SAFETY
OFF
Tamper NO
COM
GND
Tamper IN
CENTER
PHOTOCELL
UL
SAFETY
MIN
EDGE 1
MAX
OFF
ENTRAP
EDGE 2
CLOSE TIMER
BATTERY LIMIT
PACK SWITCH
ALARM
GND
STOP
MAX
GATE SPEED
OBD PORT
BLACK BOX
MIN
24VDC
MOTOR
INPUTS
12VDC
ID PLUG
ERROR
MOTOR MOTION
OPEN
POSITION
RECORDER
Power In
PARTIAL
OPEN
ID
PLUG
CLOSE
UL ALARM 12V
ALARM RET
RESET
GND
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
MOTOR
19”=1400/2200/FAST
RS-485 (+) RS-485 (-) GND PWR 24V -
1400/2200/FAST = 25”
OPEN
COM
CLOSE
GATE
STATUS
1/2
POWER
MAX BC-7
Battery Voltage
E
BATTERY
IN USE
24V
GND
SEC
GATE
OPEN
STOP
CLOSE
COM
GATE DISABLE
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
MOTOR
ON-LINE
(+)
GND
(-)
RADIO SIG.
LIMIT
SWITCH
ON-LINE
PRIMARY
GATE
(+)
GND
(-)
27.5”=1400HP
RADIO GND
GND
1400HP = 33.5”
Battery Module
F
ON/OFF Replace
Battery Battery
TEST
Battery
Battery IN
Error
6” Above Ground
Ground Level
Check local building
codes in your area for
depth of concrete
before installation.
“Optional” Input Power Note:
24VDC low voltage power wires can be run
from a remote power supply (MAX Magic
Box) to power the gate operator if desired.
See page 11 for more information.
Conduit
Concrete Pad
Input Power
Concrete Depth Note: The heavier the gate, the deeper the concrete
pad should be. At least two feet recommended for heavier gate.
Support Bar
A support bar should be installed at the gate bracket height across the ENTIRE gate to keep the gate pickets from bending.
Support Bar
Gate Bracket
YES
Support Bar Too High & Not Long Enough
NO
8
installation
dual Gate Operators
The gates must be properly installed and work freely in both directions prior to the installation of the dual gate operators.
See “Gate Operator Position” on page 6 for operator positions and previous page for arm height.
Conduit Guidelines and Suggestions
• REQUIRED - Run AC input power wire to EACH gate operator.
• REQUIRED - Entrapment protection (photocell and/or sensing edge) to EACH Corresponding
GATE OPERATOR. (see below & page 13)
Secure EACH gate
operator to concrete pad
with six (6) 1/2”x 3” (min)
sleeve anchors.
• Normally open photocell to the PRIMARY OPERATOR. (page 13)
• In-ground loop wires to the PRIMARY OPERATOR. (page 14)
Illustration not to scale
Secondary
Operator
1/2
NO Matrix 1
Primary
Operator
Matrix 1
Arms MUST be installed level.
Support Bars: See bottom of page 8.
MATRIX 1
BATTERY
BACK-UP MODE
PRIMARY
GATE
LEAVE
CLOSED
LEAVE
OPEN
MADE in USA
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
MATRIX
BOARD
MATRIX
BOARD
EXIT
ON
EXIT
CENTER
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
OFF
CENTER
RS-485 (+) RS-485 (-) GND PWR 24V -
RS-485 (+) RS-485 (-) GND PWR 24V -
PHOTOCELL
UL
SAFETY
EDGE 1
MAX
MIN
OFF
EDGE 2
ENTRAP
CLOSE TIMER
MOTOR
INPUTS
BATTERY LIMIT
PACK SWITCH
STOP
ALARM
MAX
GATE SPEED
OBD PORT
BLACK BOX
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
MOTOR OVERLOAD
MIN
MOTOR
INPUTS
Power In
MOTOR
BATTERY LIMIT
PACK SWITCH
ALARM
24VDC
Power In
GND
ID PLUG
ERROR
MOTOR MOTION
OPEN
POSITION
RECORDER
12VDC
MOTOR
PARTIAL
OPEN
ID
PLUG
OPEN
COM
CLOSE
GATE
STATUS
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
1/2
1/2
POWER
24V
GND
SEC
GATE
BATTERY
IN USE
OPEN
STOP
CLOSE
COM
GATE DISABLE
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
MOTOR
ON-LINE
(+)
GND
(-)
FIRE DEPT
GND
MAX OPEN
GND
E
TEST
Battery
PRIMARY
GATE
MAX BC-7
Battery Voltage
Battery Module
F
ON/OFF Replace
Battery Battery
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
RADIO SIG.
MAX BC-7
Battery Voltage
E
RADIO GND
GND
Battery Module
F
Battery IN
Error
ON/OFF Replace
Battery Battery
TEST
Battery
Battery IN
Error
6” Above
Ground
6” Above
Ground
To Matrix 1 SEC GATE input Conduit
Conduit
Input
Power
Check local building codes in your area for
depth of concrete before installation.
Concrete Depth Note: The heavier the gates, the deeper the concrete
pads should be. At least two feet recommended for heavier gates.
Conduit
Input
Power
“Optional” Input Power Note:
24VDC low voltage power wires can be run from a remote
power supply (MAX Magic Boxes) to power the gate
operators if desired. See page 11 for more information.
Each entrapment protection device MUST be connected to corresponding gate operator.
Dual Gates CLOSING direction Thru-Beam Photocell ONLY:
See separate wiring instruction sheet.
Reflector
Entrapment Area
CLOSING direction Photocell
To MC-200 EDGE 1 Input
OPENING/CLOSING direction Sensing Edges
Illustrations not to scale
MC-200
MATRIX
Motor Controller
ON-LINE Edge UL Entrap
1
2
MAX
LED ON
ERD
5
4
MC-200
1
2
MAX
12
16
13 14 15
LED ON
MATRIX
MADE in USA
1
POWER
IN
TO MOTOR
CONTROLLER
BATTERY
IN
BATTERY
BACK-UP MODE
LEAVE
CLOSED
OPEN
1 TIME
PRIMARY
GATE
OPEN
LEFT
LEAVE
OPEN
AUTOMATIC
OPEN/CLOSE
ANTI
TAILGATE
ON
OFF
EXIT
POWER
Limit SW Edge PhotoCell
POWER/SOLAR
IN
BATTERY
PACK
Motor Controller
MATRIX
ON-LINE Edge UL Entrap
3
ERD
POWER
IN
TO MOTOR
CONTROLLER
BATTERY
IN
JOG
JOG
LEFT RIGHT
Sensitivity
Motor
OverLoad
POWER
Limit SW Edge PhotoCell
POWER/SOLAR
IN
EXIT
BATTERY
PACK
MAGLOCK
DELAY
1.5Sec
2Sec
OPEN
RIGHT
OFF
MAG
LOCK
GATE
TAMPER
SAFETY
ENTRAP
Made in USA
NO Matrix 1
to Secondary Operator
MC-200 Edge 2 or Photo Cell
OPENING direction Photocell
Primary Operator
Matrix 1
SEC
GATE
EDGE 1
UL ALARM 12V
ALARM RET
RESET
GND
OPEN
COM
CLOSE
GATE
STATUS
OPEN
STOP
CLOSE
COM
GATE DISABLE
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
(+)
GND
(-)
RADIO GND
STOP
CLOSE
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
LIMIT
SWITCH
ON-LINE
MOTOR
ON-LINE
PRIMARY
GATE
www.max.us.com
EDGE 2
ID PLUG
ERROR
MOTOR MOTION
OPEN
MAX
GATE SPEED
MIN
MAX
(+)
GND
(-)
PARTIAL
OPEN
24VDC
GND
Secondary Operator
Tamper NO
COM
GND
Tamper IN
PHOTOCELL
UL
MIN OFF
MAX
CLOSE TIMER
POSITION
RECORDER
OBD PORT
BLACK BOX
12VDC
GND
Made in USA
COM
NC
CONTROLS
CENTER
CENTER
SAFETY
ID
PLUG
www.max.us.com
BATTERY
IN USE
POWER
24V
GND
4
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
OPEN
LIMIT
Entrapment Area
CLOSED
LIMIT
5
12
16
13 14 15
OPEN
LIMIT
JOG
JOG
LEFT RIGHT
Sensitivity
3
ERD
to Primary Operator
MC-200 Edge 2 or Photo Cell
Entrapment Area
ERD
Motor
OverLoad
to Secondary Operator
MC-200 Edge 2 or Photo Cell
OPENING/CLOSING
direction Mini
Sensing Edge
CLOSED
LIMIT
OPENING/CLOSING
direction Mini
Sensing Edge
to Primary Operator
MC-200 Edge 2 or Photo Cell
See page 13 for installation instructions.
See pages 17-18 for wiring instructions.
OPENING direction Photocell
9
installation
High Traffic Arm Option
arm position options
Gates in Closed Position
Retro-Fit Arm Option
Gate in Opened Position
Gate in Opened Position
When replacing an existing gate operator, the arm may not be able
to conform to the preferred arm position (90° from gate in open
position). The positions illustrated below can be acceptable as long
as the gate operator cycles smoothly and there is NO gate hesitation
when gate starts cycling in either direction.
90°
Arms are NOT installed in LOCKED position.
If a vehicle tries to push gates
open, arms will give when NOT
in the locked position and allow
gates to move without damaging
the gate operators.
The tamper relay will be
activated for a few seconds
which will trigger a camera or
alarm system if desired.
90°
arm connection to gate
After you’re satisfied testing the arm in the FULL OPEN and FULL CLOSED positions, weld gate bracket and arm.
Illustrations not to scale
Full Closed
JOG
JOG
LEFT RIGHT
4
MC-200
1
2
MAX
LED ON
PRIMARY
GATE
OPEN
LEFT
OPEN/CLOSE
ANTI
TAILGATE
ON
ERD
EXIT
OFF
ON
POWER
Limit SW Edge PhotoCell
POWER
IN
TO MOTOR
CONTROLLER
BATTERY
IN
PRIMARY
GATE
BATTERY
BACK-UP MODE
LEAVE
CLOSED
OPEN
1 TIME
OPEN
LEFT
OPEN/CLOSE
ANTI
TAILGATE
EXIT
BATTERY
PACK
MAGLOCK
DELAY
1.5Sec
2Sec
OPEN
RIGHT
OFF
MAG
LOCK
PHOTOCELL
UL
MAX
MIN
OFF
CLOSE TIMER
ENTRAP
PARTIAL
OPEN
mp
Arm MUST be installed level.
Limit pin MUST fit into slot in
bottom of release handle clamp
directly under the arm when
re-attaching arm to operator.
MATRIX 1
PRIMARY
GATE
BATTERY
BACK-UP MODE
LEAVE
CLOSED
LEAVE
OPEN
MADE in USA
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
MATRIX
BOARD
EXIT
ON
EXIT
CENTER
GATE
TAMPER
SAFETY
OFF
Tamper NO
COM
GND
Tamper IN
CENTER
RS-485 (+) RS-485 (-) GND PWR 24V -
PHOTOCELL
UL
SAFETY
MIN
EDGE 1
MAX
OFF
ENTRAP
EDGE 2
CLOSE TIMER
BATTERY LIMIT
PACK SWITCH
ALARM
GND
STOP
MAX
GATE SPEED
OBD PORT
BLACK BOX
MIN
24VDC
MOTOR
INPUTS
OPEN
POSITION
RECORDER
12VDC
ID PLUG
ERROR
MOTOR MOTION
Power In
PARTIAL
OPEN
ID
PLUG
CLOSE
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
UL ALARM 12V
ALARM RET
RESET
GND
OPEN
COM
CLOSE
GATE
STATUS
MAX BC-7
Battery Voltage
E
1/2
Battery Module
F
ON/OFF Replace
Battery Battery
Arm
Slot
Limit Pin
Limit Tabs
Gate Bracket
Assembly
Arm Elbow
Assembly
TEST
Battery
Battery IN
Error
BATTERY
IN USE
POWER
24V
GND
SEC
GATE
OPEN
STOP
CLOSE
COM
GATE DISABLE
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
MOTOR
ON-LINE
(+)
GND
(-)
RADIO SIG.
LIMIT
SWITCH
ON-LINE
PRIMARY
GATE
(+)
GND
(-)
RADIO GND
GND
CLOSE
1
2
ALARM 12V
ALARM RET
RESET
GND
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
LIMIT
SWITCH
ON-LINE
MOTOR
ON-LINE
PRIMARY
GATE
Made in USA
Re-Attach Arm to Operator:
EDGE
EDGE
ID PLUG
ERROR
MOTION
STOP
REVERSE SENSITIVITY
SPEED
SEC
GATE
OPEN
COM
CLOSE
GATE
STATUS
BATTERY
IN USE
POWER
24V
GND
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCEL
GND
RADIO GND
OPEN
MAX
GATE
MIN
MAX
www.max.us.com
OPEN
STOP
CLOSE
COM
GATE DISABLE
OBD PORT
BLACK BOX
24VDC
GND
RADIO SIG.
MOTOR
UL
POSITION
RECORDER
12VDC
GND
POWER
Made in USA
e Cla
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
SAFETY
ID
PLUG
OPEN
COM
CLOSE
BATTERY
IN USE
FIRE DEPT
GND
MAX OPEN
GND
1
2
ALARM 12V
ALARM RET
RESET
GND
GATE
STATUS
24V
GND
SEC
GATE
(+)
GND
(-)
CLOSE
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
LIMIT
SWITCH
ON-LINE
MOTOR
ON-LINE
PRIMARY
GATE
OPEN
STOP
CLOSE
COM
GATE DISABLE
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCEL
GND
FIRE DEPT
GND
MAX OPEN
GND
EDGE
EDGE
ID PLUG
ERROR
MOTION
STOP
REVERSE SENSITIVITY
SPEED
(+)
GND
(-)
RADIO GND
OPEN
MAX
GATE
MIN
MAX
(+)
GND
(-)
RADIO SIG.
MOTOR
UL
OBD PORT
BLACK BOX
(+)
GND
(-)
ENTRAP
PARTIAL
OPEN
POSITION
RECORDER
www.max.us.com
andl
COM
NC
CONTROLS
CENTER
OFF
CENTER
MAX
MIN
OFF
CLOSE TIMER
24VDC
GND
MOTOR
se H
MC-200
1
2
MAX
LED ON
POWER/SOLAR
IN
LEAVE
OPEN
AUTOMATIC
EXIT
Motor Controller
MATRIX
ON-LINE Edge UL Entrap
3
1
MADE in USA
COM
NC
Tamper NO
COM
GND
Tamper IN
PHOTOCELL
UL
SAFETY
12VDC
GND
weld completely around arm tubing and gate bracket.
Rele
a
4
12
16
13 14 15
MATRIX
MAG
LOCK
GATE
TAMPER
SAFETY
OFF
CENTER
ID
PLUG
Preferred arm position
is 90° from open gate.
10
5
ERD
BATTERY
PACK
MAGLOCK
DELAY
1.5Sec
2Sec
OPEN
RIGHT
CONTROLS
CENTER
JOG
JOG
LEFT RIGHT
Sensitivity
Motor
OverLoad
POWER
IN
TO MOTOR
CONTROLLER
BATTERY
IN
BATTERY
BACK-UP MODE
LEAVE
CLOSED
OPEN
1 TIME
LEAVE
OPEN
AUTOMATIC
EXIT
POWER
Limit SW Edge PhotoCell
POWER/SOLAR
IN
1
MADE in USA
Motor Controller
MATRIX
ON-LINE Edge UL Entrap
3
12
16
13 14 15
MATRIX
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
OPEN
LIMIT
5
ERD
n
CLOSED
LIMIT
ERD
Sensitivity
Motor
OverLoad
ositio
OPEN
LIMIT
Full Open
ed P
CLOSED
LIMIT
Lock
installation
optional remote power supply kit - max magic box
A remote power supply is for installations where it is too costly or difficult to trench a 115/230 VAC power line to the operator
but instead run a low voltage power line to the operator. A MAX Magic Box Kit (sold separately) is required to remotely install a
Remote MAX Megatron Toroid box.
Install the MAX Magic Box near the 115 VAC or 230 VAC input AC power source, up to 1000 ft away from gate operator.
NOTE: A MAX Magic Box kit is required for EACH gate operator when using dual gate operators.
Operator
MAX Magic Box
Near Power Source
115/230 VAC Power Source
Distance - See table below
2-Wires, 24VDC Low Voltage Power
Ca
bin
et
Re
mo
15 te
Am Tor
p B oid
ox
SU
ER
W
PO
ad
e
in
4
-2 LY
PS UPP
AX R S
M WE
SA
in
e
At Gate
Operator
MATRIX 1
ER
FF
IN
O
PO
W
N
O
230V
AC
t
or Volt
23 ag
0V e
AC :
wa
VOrran
if IDEty
la
RE be D
MO l is
VE
D
no Cond
t su ui
pp t
lied
PRIMARY
GATE
BATTERY
BACK-UP MODE
LEAVE
CLOSED
LEAVE
OPEN
MADE in USA
AC
it
Low
Voltage
ver
Se
lec
11 t In
5V pu
w
ne
se er
rvic be ct
ing fore
un
See page 20 for
MAX Magic Box
wiring instructions.
SE P
FU M
A
7
ad
M
230V
W
AR
NIN
G
!
H
VO IGH
LT
A
di
po scon GE
war
VO rant
if IDE y
la
REMbe D
l
OV is
ED
Co
Wi
Nure
ts
Re
m
15 ote
Am Tor
p B oid
ox
U
IN
AC
lect
11
To Operator
24 VDC
Po
Cower/S
nn ol
ect ar
or In
Se
5V Inpu
AC t
or Volt
23 ag
0V e:
AC
PO
SE P
FU
AM
7
F
OF
ON
!
we nn
se r ect
rvi be
cin for
g une
it
High
Voltage
-24
M
At MAX Magic Box
PO
WER
W
AR
NI
NG
H
VO IGH
LT
dis A
po co GE
Input Power
X PS
A
US
MA
Sold Separately
PP
LY
MAX Magic Box Kit
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
MATRIX
BOARD
EXIT
ON
EXIT
CENTER
GATE
TAMPER
SAFETY
OFF
Inp
Tamper NO
COM
GND
Tamper IN
CENTER
RS-485 (+) RS-485 (-) GND PWR 24V -
PHOTOCELL
UL
SAFETY
MIN
ut
A
Po C
we
r
EDGE 1
MAX
OFF
EDGE 2
ENTRAP
CLOSE TIMER
BATTERY LIMIT
PACK SWITCH
STOP
ALARM
MAX
GATE SPEED
OBD PORT
BLACK BOX
MIN
24VDC
MOTOR
INPUTS
GND
Power In
OPEN
POSITION
RECORDER
12VDC
ID PLUG
ERROR
MOTOR MOTION
CLOSE
UL ALARM 12V
ALARM RET
RESET
GND
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
MOTOR
PARTIAL
OPEN
ID
PLUG
OPEN
COM
CLOSE
GATE
STATUS
1/2
POWER
MAX BC-7
Battery Voltage
E
BATTERY
IN USE
24V
GND
SEC
GATE
OPEN
STOP
CLOSE
COM
GATE DISABLE
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
MOTOR
ON-LINE
(+)
GND
(-)
RADIO GND
LIMIT
SWITCH
ON-LINE
PRIMARY
GATE
(+)
GND
(-)
RADIO SIG.
GND
Battery Module
F
ON/OFF Replace
Battery Battery
TEST
Battery
Battery IN
Error
24
V
Lo DC
w
Vo
lt
Po age
we
r
Ground Level
Conduit
Gate Weight Max Wire Distance - Wire Gauge
1400 lbs
500 ft - 12AWG 1000 ft - 10AWG
2200 lbs
500 ft - 10AWG 1000 ft - 8AWG
24VDC Low Voltage Power
Concrete Pad
11
installation
compact installation only
Use compact installation arm measurements when area between the OPEN gate and wall is 20”min to 32”.
DO NOT use these arm measurements for a standard installation. (For standard installation, see page 6)
Hinge Pivot Point
Gate Bracket Pivot Point
Illustrations not to scale
33”
Closed Position
Open Position
Lon
26.5”
g Ar
m
OFF
1.5Sec
2Sec
MAG
LOCK
COM
NC
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
ENTRAP
PARTIAL
OPEN
MOTOR
POSITION
RECORDER
GND
1
2
ID PLUG
ERROR
MOTION
UL
12VDC
EDGE
EDGE
MAX
TIMER
OBD PORT
BLACK BOX
24VDC
OPEN
MAX
GATE
STOP
CLOSE
REVERSE
SPEED
MIN
SENSITIVITY
MOTOR
OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
ALARM 12V
ALARM RET
RESET
GND
OPEN
COM
CLOSE
GATE
STATUS
BATTERY
IN USE
POWER
24V
GND
SEC
GATE
OPEN
STOP
CLOSE
COM
GATE DISABLE
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCEL
GND
MOTOR
ON-LINE
(+)
GND
(-)
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
LIMIT
SWITCH
ON-LINE
PRIMARY
GATE
(+)
GND
(-)
RADIO GND
GND
www.max.us.com
Made in USA
4
ON-LINE Edge UL Entrap
1
2
3
MAX
12
16
13 14 15
LED ON
BATTERY
IN
1
POWER
IN
TO MOTOR
CONTROLLER
BATTERY
BACK-UP MODE
PRIMARY
GATE
LEAVE
CLOSED
MADE
in
LEAVE
OPEN
USA
AUTOMATIC
ON
OPEN
LEFT
OPEN
1 TIME
OPEN/CLOSE
ANTI
TAILGATE
EXIT
POWER
Limit SW Edge PhotoCell
POWER/SOLAR
IN
MATRIX
EXIT
BATTERY
PACK
MAGLOCK
DELAY
OPEN
RIGHT
OFF
1.5Sec
2Sec
MAG
LOCK
COM
NC
CONTROLS
CENTER
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
OFF
CENTER
PHOTOCELL
UL
SAFETY
MIN
EDGE
1
EDGE
2
MAX
OFF
CLOSE
ENTRAP
TIMER
PARTIAL
OPEN
MOTOR
ID PLUG
ERROR
MOTION
UL
POSITION
RECORDER
12VDC
GND
OBD PORT
BLACK BOX
24VDC
OPEN
MAX
GATE
STOP
CLOSE
REVERSE
SPEED
MIN
SENSITIVITY
MOTOR
OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
ALARM 12V
ALARM RET
RESET
GND
OPEN
COM
CLOSE
GATE
STATUS
GND
LIMIT
SWITCH
ON-LINE
MOTOR
ON-LINE
PRIMARY
GATE
SEC
GATE
BATTERY
IN USE
POWER
www.max.us.com
Made in USA
Cut the standard arms down to
meet the shorter measurements.
8”
18.3”
36”
Cut
20”min to 32”
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
5
ERD
ID
PLUG
24V
GND
BATTERY
PACK
MAGLOCK
DELAY
OPEN
RIGHT
CONTROLS
CENTER
PHOTOCELL
OFF
MC-200
Motor Controller
MATRIX
OPEN
STOP
CLOSE
COM
GATE DISABLE
PRIMARY
GATE
OPEN
LEFT
EXIT
OFF
UL
MIN
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCEL
GND
ON
OPEN
1 TIME
OPEN/CLOSE
ANTI
TAILGATE
CLOSE
(+)
GND
(-)
AUTOMATIC
CENTER
SAFETY
JOG
JOG
LEFT RIGHT
FIRE DEPT
GND
MAX OPEN
GND
POWER
IN
TO MOTOR
CONTROLLER
BATTERY
BACK-UP MODE
LEAVE
OPEN
USA
POWER
Limit SW Edge PhotoCell
BATTERY
IN
1
LEAVE
CLOSED
in
EXIT
RADIO GND
1
2
LED ON
POWER/SOLAR
IN
MADE
30”
ERD
Sensitivity
Motor
OverLoad
(+)
GND
(-)
ON-LINE Edge UL Entrap
MAX
12
16
13 14 15
MATRIX
rm
RADIO SIG.
4
3
ERD
ID
PLUG
25.5”
Operator Pivot Point
Wall
OPEN
LIMIT
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
CLOSED
LIMIT
5
MC-200
Motor Controller
MATRIX
rt A
Arm Elbow Pivot Point
OPEN
LIMIT
JOG
JOG
LEFT RIGHT
8”
Sho
CLOSED
LIMIT
ERD
Sensitivity
Motor
OverLoad
Entrapment Area
23”
10”
Long Arm
Cut
4”
22”
24”
Short Arm
It is necessary to protect against the entrapment
that could occur with this type of installation.
(See entrapment protection on page 13)
20”
Cut
4”
solar - Optional
Refer to Solar application guide.
MAX Solar Power Kit: MUST be used
when using solar power. Sold separately.
el
an
r P Volt
a
l
So 24
Solar Panel: must be mounted facing
south. It must get full sunlight throughout
the day, NO shadow obstructions.
MAX
Solar
Power
Kit
MAX Solar Kit
Po
Cower/S
nn ol
ect ar
or In
MATRIX 1
PRIMARY
GATE
BATTERY
BACK-UP MODE
LEAVE
CLOSED
LEAVE
OPEN
MADE in USA
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
ANTI
TAILGATE
MATRIX
BOARD
ON
EXIT
CENTER
MAG
LOCK
GATE
TAMPER
SAFETY
OFF
COM
NC
Tamper NO
COM
GND
Tamper IN
CENTER
PHOTOCELL
UL
SAFETY
MIN
EDGE 1
MAX
OFF
ENTRAP
EDGE 2
CLOSE TIMER
MOTOR
INPUTS
BATTERY LIMIT
PACK SWITCH
STOP
ALARM
MAX
GATE SPEED
OBD PORT
BLACK BOX
MIN
24VDC
Power In
GND
ID PLUG
ERROR
MOTOR MOTION
OPEN
POSITION
RECORDER
12VDC
CLOSE
UL ALARM 12V
ALARM RET
RESET
GND
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
MOTOR
PARTIAL
OPEN
ID
PLUG
OPEN
COM
CLOSE
GATE
STATUS
E
1/2
MAX BC-7
Battery Module
F
ON/OFF Replace
Battery Battery
TEST
Battery
Battery IN
Error
BATTERY
IN USE
POWER
24V
GND
SEC
GATE
OPEN
STOP
CLOSE
COM
GATE DISABLE
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
MOTOR
ON-LINE
(+)
GND
(-)
RADIO SIG.
LIMIT
SWITCH
ON-LINE
PRIMARY
GATE
(+)
GND
(-)
RADIO GND
GND
Battery Voltage
12
2Sec
AUTOMATIC OPEN/CLOSE CONTROLS
EXIT
RS-485 (+) RS-485 (-) GND PWR 24V -
Wi
Nure
ts
el
an
r Pnics
a
l
So ctro
Ele Box
Solar Panel
Electronics
Box
installation
entrapment protection
Install photocells and/or sensing edges to help protect against entrapment during cycling of the gate (entrapment protection).
ONE entrapment protection sensor MUST be installed and connected to “Edge 1 CLOSING direction” on MC-200 motor
controller or operator will NOT function. Entrapment protection sensors MUST be MONITORED and NORMALLY CLOSED (N.C.).
IMPORTANT: Sensing edges MUST be Monitored 10K Normally
Closed Type and a GEM-104 module MUST be installed.
Top View
Beam: 5” or LESS from CLOSED gate.
Wireless
Module
CLOSING direction photocell to
MC-200 EDGE 1 input, Monitored.
Normally CLOSED (N.C.)
Entrapment Area
Gate Closed
WIRELESS NOTE: Refer to the instruction sheet that
comes with the wireless module for wiring and
mounting instructions when using wireless option.
Max 10K Mini Sensing Edge (N.C.)
Clo
Clo
sed
Hinge Area
Entrapment
Area
End of Gate Options
Gate Open
Conduit
sed
Ga
te
Ga
te
ed
los
te
Ga
C
OPENING/CLOSING
Two Sided 10K Sensing Edge
to Edge 2 or Photo Cell input
MC-200 Edge 2 or Photo Cell input
CLOSING ONLY
One Sided
10K Sensing Edge
MC-200 Edge 1 input
IMPORTANT:
See pages 17-18 for wiring
instructions.
The hinge area may need protection
against entrapment. MAX 10K mini
sensing edge works well in this area.
(OPEN/CLOSE direction, MC-200
Edge 2 or Photo Cell input)
Dual Gate Operators NOTE: Run EACH entrapment
protection sensor to each corresponding GATE
OPERATOR’S MC-200 motor controller. See page 9.
Photocells MUST
be in alignment
or fault will occur.
Normally CLOSED (N.C.)
OPENING direction Photocell
OPENING/CLOSING or
Closing ONLY 10K (N.C.)
Sensing Edge
Bottom of Gate
IMPORTANT: Photocells
MUST be Monitored
Normally Closed Type.
Side View
then a 10K sensing edge should be installed.
Gate Open
OPEN/CLOSE Sensing Edge on Bottom of Gate: If
6” or More the bottom of gate is 6” or higher above the ground,
OPENING direction Photocell,
Install just above gate operator.
CLOSING direction Photocell
IMPORTANT: Photocells MUST
Beam Height:
21” Normal
27.5” Max.
be in alignment or fault will occur.
Entrapment Protection
10K Sensing Edge,
Install along entire
edge of gate.
13
installation
in-ground loops
Install in-ground loops to help
protect vehicles from a moving
gate. See pages 25 & 29 for
wiring instructions.
Refer to loop maunufacturer’s
instructions to determine specific
loop dimensions.
Safety
Loop
4 ft
Outside Property
4 ft
It is recommended that a
licenced installer perform
this work.
4 ft
Illustration not to scale
4 ft
Inside Property
Conduit
Lead Wires
Side View of
Saw Cut
Sealant
Backer Rod
Center
Loop
1 1/2”
Typical
Saw Cut
Loop Wire
1/4” Saw Cut
4 ft
Pavement
Safety Loops
Lead Wires
Safety
Loop
Are placed on each side of the gate to prevent
the gate from closing on a vehicle in it’s path.
They will stop or reverse the cycling of the
gate while a vehicle is in or near the gate’s
pathway.
Loop lead wires are
twisted 6 twists per
foot minimum inside
conduit.
4 ft min.
Center Loop
Will ONLY HOLD the gate in the Full Open
Position when a vehicle is on the center loop.
However, it WILL NOT stop or reverse the
gate once it starts to close.
Exit
Loop
4 ft
4 ft
Matrix 1 Wiring
Exit Loop
MATRIX 1
PRIMARY
GATE
EXIT
OPEN
LEFT
OPEN
1 TIME
LEAVE
OPEN
MADE in USA
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TTAILGATE
EXIT
ON
EXIT
CENTER
GATE
TAMPER
SAFETY
OFF
Tamper NO
COM
GND
Tamper IN
CENTER
CENTER
PHOTOCELL
Lead Wires
UL
SAFETY
MIN
EDGE 1
MAX
OFF
ENTRAP
EDGE 2
CLOSE TIMER
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
POSITION
RECORDER
12VDC
GND
OBD PORT
BLACK BOX
24VDC
OPEN
STOP
MAX
GATE SPEED
MIN
CLOSE
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
UL ALARM 12V
ALARM RET
RESET
GND
OPEN
COM
CLOSE
GATE
STATUS
BATTERY
IN USE
POWER
24V
GND
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
Outside Property
SAFETY LOOP
SAFETY LOOP
CENTER LOOP
RADIO GND
GND
RADIO SIG.
SAFETY
Safety loops need
to be wired in series.
EXIT LOOP
Inside Property
14
BATTERY
BACK-UP MODE
LEAVE
CLOSED
Automatically opens the gate for exiting
vehicles without having to use a radio
transmitter (remote control). The exit loop
can be placed a minimum of 4 feet away from
the safety loop or far enough away from the
gate so it has opened by the time the vehicle
approaches it.
installation
install warning signs
A minimum of two (2) WARNING SIGNS shall be installed,
one on each side of the gate where easily visible.
M
Seovin
KE rio g
EP u G
witho
CL s ate
Do ut priEAR! In
C
in not or wa Gajury an
the let
te
Th ga child rning ma o Ca
Peis en te are ren . y mor D use
de tra
ve ea
str nc a. opera
at
ian e is
an th
te
s mu for
y tim
the
ga
st vehic
e
us
te
e se les
or
pla
pa only.
y
rat
e en
tra
nc
e.
Moving Gate Can Cause
Injury or Death
Moving Gate Can Cause Serious
CLEAR! Gate may move at any time
Serious Injury or Death KEEP
without prior warning.
KEEP CLEAR! Gate may move at any time
without prior warning.
Do not let children operate the gate or play
in the gate area.
This entrance is for vehicles only.
Pedestrians must use separate entrance.
Do not let children operate the gate or play
in the gate area.
This entrance is for vehicles only.
Pedestrians must use separate entrance.
Wiring operator
Check with local building department prior to installing any permanent wiring on this gate operator. Make sure all wiring
complies with local code requirements.
Gate Operator Overview
1 MAX Megatron Toroid Box: AC power management for the
AC input power to the gate operator. See pages 19, 20 & 23.
2 Release Handle Clamp: Manually move the gate when
2
handle is raised. See page 41.
3 Audible Alarm: Sounds when there is a problem with cycling
8
D
R ty
E vi
iti
ns
Se
r d
oto oa
M rL
ve
O
D
R
E
5
4 3
12
13
14
15 16
X
A ON
M LED
GT
JO EF
L
7
G T
JO H
IG
R
4
5
1
it
En
ell
R
E
CO
LIM
SW IT
ON ITCH
-LI
NE
MO
ON TOR
PR
IMAR -LINE
PHOTOCELL
GND
GA
STATTE
US
(+)
GND
(-)
GA Y
TE
SE
GA C
TE
24V
GND
(+)
GND
(-)
tte
ry
E
ED
UL
OPEN
STOP
CLOSE
COM
GATE DISAB
LE
FIRE DEPT
GND
MAX OPEN
GND
STRIKE
GND
KEYPAD
/ RDR
GND
ITIVIT
Y
R OV
ER
NO
LO
AD
LIM
CLAM IT
SW
P SL ITC
IPP H /
ING
GE
TO
EN
TR
AP
NS
TO
OT
OC
ELL
R
ALA
RM
LIM
SW IT
ITC
H
BAT
RADIO SIG.
TER
PAC Y
K
MO
TO
INP R
UT
S
In
Ba
PH
1
MO
MAT
BO RIX
AR
D
RADIO GND
Tam
per
NO
CO
M
Tam GND
per
IN
er
ION
5
M
NC
CLOS
E
E SE
W
MOT
er
oll
4
MAG
LO
CK
GA
TAM TE
PER
UL
VERS
MO
tr
2Sec
SA
FETY
RE
O
P
oC
ot
Ph
EED
on
Sec
RO
STOP
SP
0
MAG
DE LOCK
LA
1.5 Y
OP
EN
GA
TE
MC
-20
C
ge
MAX
MIN
MA
X
r
Ed
OB
BLACD PO
K BORT
X
p
tra
24VD
C
GN
D
oto
OFF
LS
ER
MOT
OR
PO
RE SITION
CO
RD
ER
2
RS-485 (+) RS-485 (-) GND PWR 24V -
CO
NT
9
PART
OP IAL
EN
12VD
C
GN
D
UL
SE
MIN
CLOS OFF MAX
E TI
MER
M
SW
OP
EN
RIGH
T
LO
CENT
SA
FET
Y
ID
PLUG
1
OP
LE EN
FT
OP
EN
/C
EXIT
OFF
ge
Lim
PR
IM
GA ARY
TE
OP
EN
1 TIM
E
ON
CENT
ER
Ed
TAIL TI
GA
TE
ON
-LIN
E
X
EXIT
2
o
Ed Phot ll
Ce
RI
LEAV MOD
LEAV
E
OP E CLOS E
EN
ED
AU
TO
MA
TIC
AN
AT
BA BATT
CK ER
-UP Y
in US
A
M
MA
DE
Pow
MA
TR
IX
g LT
Jo g RT
Jo GND 1
ge
Ed ge
ED
GE
2
ID
PL
ER UG
RO
R
ALAR
ALAR
M 12
V
M RE
RE T
SE
GN T
D
on
cti
prote
ed the
nu th
nti ly wi
r co on fuse.
s
: Foplace g of
pa les
ne ntre e
NING , re ratin
ur
fire d
po on cofusibl
WAR st e an
T:
s
ain
EN otecti un ue
ag typ
me
EMla pr liser ristiq
sa
uti
TISSttre die, racté
ER
ca
AV romencene et
mp d’i
co es s typ
qu
ris me .
mê
de nales
mi
no
OP
EN
CO
CLOSM
E
BATT
ER
IN Y
US
E
PO
WER
p
7 Am
SE
FU
On ER
3A
W
AC
PO
5V
11
Off
max
6
1
7
Vo
lta
1/2
ge
F
ON
/O
Ba FF
tte
ry Repla
Ba ce
tte
ry
MA
XB
Ba
tte
ry
TE
ST
Ba
tte
ry
8
C-7
Mo
du
le
Ba
tte
ry
Error IN
6
3
9
the gate. Push the STOP button on the Matrix 1 or an
externally mounted Alarm Reset button to shut-off alarm.
Alarm can sound every time operator is cycled using ONLY
battery back-up power when turned ON, See page 32.
24VDC Brushless Motor (6 million cycles)
MAX MC-200 Motor Controller: Manages UL entrapment
protection devices and operator motor reversing ERD
sensitivity adjustment. See pages 19, 20, 22, 25 & 34.
MAX BC-7 Battery Module: Battery Back-Up and DC power
management for the gate operator. See next page.
Limit Tabs: Adjusts the OPEN and CLOSE gate positions.
See page 35.
Limit Switch Box: Contains the limit switches. Gate operator
will NOT function when limit switch box is not connected.
See page 35.
Matrix 1: Manages control panel operations. Manages
inputs/outputs, loops and reports problems with gate
operator. See Matrix 1 Section starting on page 24.
15
Wiring operator
MAX BC-7 Battery Module
1 BATTERY Plug: MUST be plugged into BATTERY IN port Before use.
2 POWER/SOLAR IN Port: MAX Megatron Toroid box connection.
3 Battery Voltage LEDs: Show amount of battery power available.
LEDs are always ON when using AC power. Test battery button must be
pressed to show battery power when using battery power ONLY.
R
WE
IN
PO
ry
tte
Ba Pack
4 ON/OFF Battery Button:
IMPORTANT: Battery power automatically turns ON when MAX Megatron
Toroid Box AC POWER Switch is turned ON.
w
w
w
.M
ax
.
U
S
.c
om
R
TO R
MO LLE
TO TRO
N
CO
AR
PO
OL
IN
R/S
WE
PO
R/S
IN
OL
AR
WE
2
-7
BCule
AX Mod
6
Y
ER
TT
IN
BA
Mttery
Ba
4
ge
lta
Vo F
ry
tte /2
Ba
1
BA
TT
IMPO
RTA
NT
co
“BA nnect to
TT
befo ERY IN
”
re u
se
ER
IN Y
E
IN
ry
tte
Ba rror
E
ST
TE ry
tte
To turn OFF ALL POWER to operator:
7
Ba
ce
pla
Re ery
FF Batt
/O
ON ery
tt
Ba
1. Turn OFF AC POWER Switch on MAX Megatron Toroid Box.
Battery power remains ON.
2. WAIT for 15 seconds.
3. Press and HOLD (approx. 5 seconds) the RED ON/OFF BATTERY
button until MAX BC-7 LEDs turn ON, then release button.
LEDs will turn OFF.
5
3
1
5 Replace Battery LED: Replace battery when lit.
6 TEST Battery Button: Press to show amount of battery power available when
using battery power ONLY (Battery voltage LEDs will light respectively).
7 Battery IN Error LED: Lights when there is a battery connection problem.
Make sure battery plug #1 is plugged into BATTERY IN port or there is no
damaged or loose wires.
-2
C
M
p
ra
E
L
U
ell
e
C
dg
ho
to
E
e
P
1
dg
2
T
US .
3 Mnsors 3 : be be
2 & R se 2 & UST can be
uts ITO uts rs M ey ST
Inp ON inp enso RE th MU
M RN
S FO puts
an
D E
to EA
ll c
RE B d in
L
Ce
to
ITO puts use
To
3
2
F INPUTS:
Jog LT/RT inputs: Can connect to an External Open/Close Key switch.
Connect a single key switch to control dual gate operators, See page 34.
GND input: Low Voltage Common connection.
1
r In
SW
M
AR
AL
-
P
G Matrix On Line LED: Gate operator is successfully communicating with
Matrix 1 when lit.
H Limit SW On Line LED: Limit Switch Sensors are successfully
communicating with MC-200 Motor Controller when lit.
I Edge 1 LED: Edge 1 sensor has been activated when lit.
J Edge 2 LED: Edge 2 sensor has been activated when lit. LED will light up
during “LEARNING” mode when sensor is connected, see page 18.
K Photocell LED: Photocell sensor has been activated when lit. LED will light
L
up during “LEARNING” mode when sensor is connected, see page 18.
M
UL Entrap LED: Edge1/Edge2/Photocell inputs have been activated when lit.
N
Power LED: Low voltage power is connected when lit.
RS-485 Input: Factory wired for Primary operator.
Wire to Matrix 1 “SEC GATE” for Secondary operator ONLY.
24V Power Input: 24V Power for Matrix 1 ONLY.
12V Entrapment Protection Sensor Power Out: 12V Power that ALL
Entrapment protection sensors MUST use PWR 12V power.
16
E Jog LEFT/RIGHT Buttons:
Push and HOLD buttons accordingly to move the gate (release the button to
stop gate). WARNING: Avoid moving gate while using Jog buttons.
we
O
P
C ERD Sensitivity Knob: 16 selectable sensitivity settings of ERD sensor.
D ERD Sensitivity LED: MAX sensitivity reached when lit.
Po
N
O
B ERD LED: ERD sensor has been activated when lit.
R
TO
MO
-
RS-485 (+) RS-485 (-) GND PWR 24V -
GND PWR 12V -
IX
un
A MOTOR OVERLOAD LED: Excessive current being drawn by motor when lit.
Entrapment Protection Sensor Inputs
S
MC-200 Swing
16
15
TR
MA
J
H
o
ON to in y un
P
Ph .
1.Mired . An
/or r 3 STO 1
nd 2 o
w ed .
e a put N & trix s.
rn d
lea pere Edg er in OPE n Ma egin
b
g h
jum ersin eit the me o ode
D
ev ed to OL me ti rn m
R
ir
.
H
2 e w nd
sa lea
b s a the ard, ON
t
res s a he MOTI
3.Putton ep is OTOR
M
b l be
ti
d
OSE
un
ate
CL
dic
OP . in
d
ST 5 min
cte
r
EN
ete ON
OP sts fo
h d be
la
ac ILL
e
e
r
d
fo s W al
mo .
ON LED du
arn ing
in.
Le eep L be 00. hen
5 m,
w
b
-2
hin ode
by s WIL MC 00s
wit
in rn m
ED r on C-2 d.
4.L nso TH M use aga lea
se BO are tton end
u
rs
d
for rato P b an
D.
O rs
e
RE
op s ST nso
ITO
e
res s ps. ON
5.P learng sto w M
to pin no
re
e
be ts a
u
Inp
LE
.
ns
tio .
D
uc
tor a
str ation
14
ll
MoerLo
n in
12 13
tio ’insta
lla
Ov
D
sta tice d
ER B
in
e
no
ed
Se
n
or
ir la
N:
tio
nit g
IO N: Vo
r
tec
Mo ersin
UT
ro es 1 o
v
CA NTIO
t P lin GE
Re e
en uide ED
TE
g
T
d
m
to
A
E
p G ed n.
ir o
tra or
En ens be wfuncti (N.C.)ach
OR
e tors
S UST OT
ED to
red
OS Y, era
rM N
ito
so ILL CL ONL al op
on
Y rs du
en r W
M
o
L
s
t
o
an
• Aperato RMALsensowhen
Ph
ll c
o
Ce
ell
NO RED -200
to
C
e
o
ir O C
.
h
r P puts to
• WONITtor’s M
d/o In sed
M ra .
an e 3
u
e
op used dge of th T be
E
.
GND
ed
are ing ANY MUS sors
us
ers d to
V sen
v
in
2
be
e
a
1
ST
• Re wire PWRORED T remcur.
MU
b
00 NIT MUS ill oc
2V
n
1
-2
O
w
C M
tio
ts
WR
tec
• Mower inpur fault
ro
0P
D o
p
t p 2V
-20
SE ED
en R 1
R
MC
NU ER
TO
pm PW
U
P
a
• UM
MO UTS
ntr 00
P
J
r e -2
IN
Y
ER
we MC
TT
po ith
BA CK
LY s w
PA
IT
ON sor
IM
L CH
n
IT
se
1
C
Ad
E
S
Lim
it
GND Edge 1
Jog LT Jog RT -
N
A
X
E
O
M
5 4 3
D
D
ity
R
tiv
E
si
en
1
M
K
n
ctio
ote
Pr per
nt jum
meUST
p
”
tra M
ED
En ts: puts
RN
3 Inpued in
EA
“L
2
us
be
W
M
O A
N TR
-L I
IN X
E
J
Jo og L
g
T
E G RT
E dg ND
P dge e 1
Ce hoto 2
ll
F
HT
Co
nt
I
G
G
JOIG
R
G
JO EFT
L
tor
MoL
Edge 2
Photo Cell
Continued on next 2 pages.
er
oll
ntr
R
WE
PO
00
MAX MC-200 Motor Controller
Edge 1-MONITORED CLOSING direction ONLY input: Connects to a
NORMALLY CLOSED (N.C.) Sensing Edge or Photocell.
Closing direction activation: gate will reverse to full open position and
reset close timer.
Opening direction activation: gate will NOT be monitored during
opening cycle.
Edge 2-LEARNED MONITORED OPENING/CLOSING direction input:
Connects to a NORMALLY CLOSED (N.C.) Sensing Edge or Photocell.
Input MUST be “LEARNED” before it can MONITOR a connected sensor
(see page 18).
Closing direction activation: gate will REVERSE to full open position but
will NOT reset close timer. Another command is required for gate to
resume operation.
Opening direction activation: gate will REVERSE 2 inches and STOP.
Another command is required for gate to resume operation.
Photo Cell-LEARNED MONITORED OPENING/CLOSING direction input:
Connects to a NORMALLY CLOSED (N.C.) Sensing Edge or Photocell.
Input MUST be “LEARNED” before it can MONITOR a connected sensor
(see page 18).
Closing direction activation: gate will STOP. Another command is
required for gate to resume operation.
Opening direction activation: gate will STOP. Another command is
required for gate to resume operation.
DUAL GATE OPERATORS NOTE: Connect EACH photocell/sensing
edge to the corresponding gate operator’s MC-200. See page 9.
Wiring operator
5
Jog LT
JOG
JOG
LEFT RIGHT
Sensitivity
Jog RT
ERD
Motor
OverLoad
GND
Edge 1
Edge 2
Photo
Cell
entrapment protection wiring
MC-200
MATRIX
4
1
2
1 2 3
MAX
12
16
13 14 15
Motor Controller
ON-LINE Edge UL Entrap
3
ERD
Jumper UNUSED Entrapment Protection Inputs
or a fault will occur.
LED ON
Normally Closed (N.C.)
POWER
Sensor Wire
Limit SW Edge PhotoCell
1
GN
D
EDGE 1: MONITORED CLOSE ONLY
Edge 2: LEARNED MONITORED OPEN/CLOSE
Photo Cell: LEARNED MONITORED OPEN/CLOSE
Typical Wiring For:
3
2
Example: Inputs 2 & 3
are NOT used and MUST
be jumpered to GND.
a 10K Normally Closed (N.C.) Sensing Edge ...... AND/OR ........ a Normally Closed (N.C.) Photo Cell
IMPORTANT Sensing devices MUST be powered by
MC-200 or they will NOT be MONITORED.
00
er
C C
on -2
tr 0
oll 0
er
M
E
or
ot
ap
O
W
M
ntr
E
P
Power
L
U
1
SW
to
E
P
ho
1
dg
e
2
M
O A
N TR
-L IX
IN
E
W
S
See next page for a specific
photocell’s N.C.- N.O. input.
Re
fle
Be ctive
am
R
TO
MO
Po
r
we
In
r
tte
IT
s
AL
e
do
D
GN olarity
P
2V
R1
-
RS-485 (+) RS-485 (-) GND PWR 24V -
M
AR
T
NO
ma
To MC-200 Power
To GND
To Edge 1
NORMALLY CLOSED
CLOSING direction Photocell
Max 10K Mini Sensing Edge (N.C.)
Wireless Option: See separate wiring instruction sheet.
Gate Edge Module (GEM-104)
OPENING/CLOSING
10K MAX Mini Sensing Edge
to Edge 2 or Photo Cell input
Entrapment
Area
CLOSING ONLY
One Sided
10K Sensing Edge
to EDGE 1 input
(to wireless module
when using Wireless
Option).
OPENING direction Photocell
Normally CLOSED (N.C.)
Gate Open
OPENING/CLOSING
Two Sided 10K Sensing Edge
to Edge 2 or Photo Cell input
(to wireless module when
using Wireless Option).
te
sed
tor
flec
Re
Polarity does NOT matter
Gate Closed
Ga
IMPORTANT: Photocells MUST
be in alignment or fault will occur.
Wireless
Module
Clo
s
it
T
un
US .
3 Mnsors 3 : be be
2 & R se 2 & UST can be
uts ITO uts rs M ey ST
Inp ON inp enso RE th MU
N
M
n
ts
to EAR ED SBEFOinpu
l ca
R
L
Cel
To NITOinputs used
to
Entrapment Area
End of Gate
Options
Tra
n
on
cti
PW
sed
am
Lim
3
4
3
LE
IX
GND
te
Be
Power
un
O to
P
Pho 3.
1.Mired Any
d/or 2 or STO 1
w ned.
e an put N & rix .
d.
learpere Edg er in OPE Mat gins
be
jum ersing eith the e onode
D
ev d to OL e timn m
2.R wire d H sam lear
be an the ard,
N
ress at he MOTIO
3.P ttonsep is MOTOR
bu be
E
til
OS
ted
un
CL
dica
OP . in
ST 5 min
ed
r
EN
tect ON
de
OP sts fo
ch L be
e la
r ea WIL
mod
N fo Ds al
arn ing. O LE du
in.
Le ep L be 00. hen
5m
be IL C-2 s w
in e,
by s W M 00
ith od
D on C-2 .
nw nm
4.LEnsorTH Me used agai lear
se BO ar tton end
s
for ator P bus and
D.
er
RE
op STOnsor
ITO
ress n se s. ON
5.P lear g stop w M
to in e no
ep
be ts ar
Inpu
2
-
TR
MA
GND PWR 12V -
-
RS-485 (+) RS-485 (-) GND PWR 24V -
.
ns
tio
16
uc o n .
15
str
ti
14
lla
n in
12 13
tio ’insta
lla
sta ce d
e in noti
d
Se
la
n
:
ore
ir
N
tio
nit g
IO N: Vo
r
tec
Mo ersin
UT
ro es E 1 o
v
CA NTIO
t P lin
Re e
en ide EDG
TE
g
to
AT
Ed
pm Gu
tra sor wiredtion. .)
n
R
c
h
.C
e
E en b fun
O
(N eac rs
S UST OT
D
d
SE , to rato
M N
ore
or ILL CLO NLY l ope
nit
O
ns
Mo to
LY rs dua
se r W
o
an
• Aperato RMALsensowhen
Ph
ll c
o
ll
Ce
NO ED 00
to
Ce
ire OR C-2
ho .
r P puts to
• WONITtor’s M
/o
d
In
d
e
M ra .
an e 3
us
e
op used dge of th T be
E
.
d
GND
are ing ANY MUS sors
se
ers
V sen
eu
ev d to 12
ain
Tb
• Re wire PWRORED T remcur.
US
b
VM
00 NIT MUS ill oc
n
12
w
C-2 MO
tio
R
ts
tec
• Mower inpur fault
PW
ro
p
00
ED o
t p 2V
C-2
en R 1
US RED
R
M
N
m
E
TO
p W
• UUMP
MO UTS
tra 0 P
en 0
J
INP
Y
er C-2
ER
ow h M
TT
BA CK
Y p wit
L
PA
IT
ON sors
LIM CH
n
se
1
IT
M
Ga
ru-
C
ell
dg
e
X
N
A
O
M
Edge 2
Photo Cell
Jog LT Jog RT -
1
J
LE OG
F
T
MC-200 Swing
R
TO
MO
r In
we
Po
PWR 12V
sed
Th
cr
te
ro r
t P pe
en jum
pm UST
”
tra M
ED
En ts: puts
RN
3 Inpued in
EA
“L
2
us
be
D
S E
en R
sit D
iv
ity
5
O M
ve o
rL tor
oa
d
D
R
E
un
O to
P
Pho 3.
1.Mired Any
d/or 2 or STO 1
w ned.
e an put N & rix .
d.
learpere Edg er in OPE Mat gins
be
jum ersing eith the e onode
D
ev d to OL e timn m
2.R wire d H sam lear
be an the ard,
N
TIO
ress at he MO
3.P ttonsep is MOTOR
bu be
E
til
OS
ted
un
CL
dica
OP . in
ST min
ed
EN r 5
tect ON
de
OP sts fo
ch L be
e la
r ea WIL
mod
N fo Ds al
arn ing. O LE du
in.
Le ep L be 00. hen
5m
be IL C-2 s w
in
e,
by s W M 00
ith od
D on C-2 .
nw nm
4.LEnsorTH Me used agai lear
se BO ar tton end
s
for ator P bus and
D.
er
RE
op STOnsor
ITO
ress n se s. ON
5.P lear g stop w M
to in e no
ep
be ts ar
Inpu
R JO
IG G
H
T
T
US .
3 Mnsors 3 : be be
2 & R se 2 & UST can be
uts ITO uts rs M ey ST
Inp ON inp enso RE th MU
N
M
n
ts
to EAR ED SBEFOinpu
l ca
R
L
Cel
To NITOinputs used
to
Polarity does NOT matter
Clo
Re
R
ell
C
to
P
ho
1
dg
e
2
un
E
-2
oll
tr
C
on
M
C
E
R
or
ot
ap
O
W
M
ntr
P
E
L
U
dg
e
3
2
1
SW
AR
AL
E
S
it
LE
1
GND PWR 12V -
IX
E
W
M
O A
N TR
-L IX
IN
E
Lim
GND Edge 1
X
N
A
O
M
D
D
iv
sit
R
O M
ve o
rL tor
oa
d
MC-200 Swing
E
R
D
S
5
4
3
en
E
ity
One Sided Edge
J
LE OG
F
T
Jog LT Jog RT -
1
.
ns
tio
16
uc on.
15
str
ti
14
lla
n in
12 13
tio ’insta
lla
sta ce d
e in noti
d
Se
la
n
:
ore
o
ir
N
ti
nit g
IO N: Vo
r
tec
Mo ersin
UT
ro es E 1 o
v
CA NTIO
t P lin
Re e
en ide EDG
TE
g
AT
Ed
pm Gu ed to .
ir on
tra or
R
En ens be wfuncti (N.C.)ach
O
e
rs
S UST OT
D
d
SE , to rato
M N
ore
or ILL CLO NLY l ope
nit
O
ns
Mo to
LY rs dua
se r W
o
an
• Aperato RMALsensowhen
Ph
ll c
o
ll
Ce
NO ED 00
Ce
oto
ire OR C-2
Ph uts.
• WONITtor’s M
/or Inp ed to
d
M ra .
an e 3
us
e
op used dge of th T be
E
.
GND
ed
are ing ANY MUS sors
us
ers
V sen
be
ev d to 12
ain
ST
• Re wire PWRORED T remcur.
MU
b
00 NIT MUS ill oc
2V
n
w
C-2 MO
tio
R1
ts
tec
• Mower inpur fault
PW
ro
p
00
ED o
t p 2V
C-2
en R 1
R
US R E D
M
N
m
E
TO
p W
• UUMP
MO UTS
tra 0 P
en 0
J
INP
Y
er C-2
ER
ow h M
TT
BA CK
Y p wit
L
PA
IT
ON sors
LIM CH
n
se
TR
MA
on
cti
rote r
t P pe
en jum
pm UST
tra M
D”
NE
En uts:inputs
R
3 Inp ed
EA
“L
2
us
be
Edge 2
Photo Cell
R JO
IG G
H
T
J
Jo og L
g
T
E G RT
E dg ND
P dge e 1
Ce hoto 2
ll
GEM-104
EDGE 1 (N.C.)
CLOSING
Direction
ONLY
J
Jo og L
g
T
E G RT
E d g ND
P dge e 1
Ce hoto 2
ll
ON = Obstruction
BLINKING = Fault
MON.
PWR
SAFETY
INPUT
C.) on
(N. recti
1
Di LY
GE
ED SING ON
O
CL
GND (C)
GEM - 104
C)
D(
GN
GND Edge 1
10K Edge
Normally
Closed
te
Ga
Clo
MUST be used with EACH Normally Closed
10K type Sensing Edge.
IMPORTANT:
To
Normally Closed
10K Sensing Edge
10K Edge
Normally
Closed
GEM - 104
To MC-200 Power
(Polarity does NOT matter)
ON = Obstruction
BLINKING = Fault
MON.
PWR
SAFETY
INPUT
To MC-200
GND
To MC-200
Edge 1, Edge 2,
or Photo Cell
NOTE: see next page
for sensor model #s
and Learning Edge 2
and Photo Cell inputs.
To GEM-104
To GEM-104
OPENING/CLOSING or
Closing ONLY 10K (N.C.)
Sensing Edge
(Hardwired)
Photocells MUST
be in alignment
or fault will occur.
To MC-200 Edge 2 or Photo Cell
To GND
To MC-200 Power
(Polarity does NOT matter)
DUAL GATE OPERATORS NOTE: Connect EACH photocell/sensing edge to the corresponding gate operator. See page 9.
17
GND
Edge 1
Edge 2
Photo
Cell
JOG
JOG
LEFT RIGHT
Sensitivity
5
Jog LT
ERD
Motor
OverLoad
Jog RT
Wiring operator
4
ERD
ON-LINE Edge UL Entrap
1
3
MC-200
1
2
2 3
MAX
12
16
13 14 15
Motor Controller
MATRIX
LED ON
POWER
Limit SW Edge PhotoCell
EDGE 1 Note: CLOSING direction ONLY.
Inputs 2 & 3 MUST be “LEARNED” to MONITOR OPENING/CLOSING direction sensors.
To LEARN inputs 2 & 3 :
1. MONITORED Sensors MUST be wired to inputs BEFORE they can be learned.
Any unused inputs MUST be jumpered, see previous page.
2. A Sensing Edge or Photo Cell can be wired to either input 2 or 3.
MATRIX 1
BATTERY
BACK-UP MODE
PRIMARY
GATE
LEAVE
CLOSED
OPEN
LEFT
OPEN
1 TIME
LEAVE
OPEN
MADE in USA
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
EXIT
3. Press and HOLD the STOP button & then the OPEN button
together on Matrix 1 until beep is heard, learn mode begins.
NOTE: DO NOT press the OPEN button before the
STOP button or learn mode will NOT function.
ON
EXIT
CENTER
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
OFF
CENTER
PHOTOCELL
MOTOR MOTION
EDGE 1
UL
SAFETY
MIN
MAX
OFF
EDGE 2
ENTRAP
CLOSE TIMER
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
OPEN STOP
CLOSE
OPEN
POSITION
RECORDER
12VDC
GND
STOP
MAX
GATE SPEED
GA
OBD PORT
BLACK BOX
CLOSE
REVERSE SENSITIVITY
MOTOR OVERLOAD
MIN
24VDC
UL ALARM 12V
ALARM RET
RESET
GND
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
OPEN
COM
CLOSE
GATE
STATUS
GND
Edge 1
Edge 2
Photo
Cell
Jog LT
Jog RT
4. LEDs WILL be ON for
each detected sensor on MC-200.
ERD
MC-200
JOG
Sensitivity
JOG
Motor Controller
Motor
MATRIX
LEDs WILL
be
ON
for
BOTH MC-200s
when
dual operators ON-LINE
LEFT RIGHT
Edge UL Entrap
OverLoad
5
4
1
3
P
POWER
are used. If an LED is not
on and it should be, wiring to1 2 3
MAX
2
ERD
sensor is bad,
photocells
are
out
of
alignment,
photocells
12
16
LED ON
PhotoCell
P
hotoCell
hotoCe
hotoCel
otoC
otoCe
Limit SW Edge PhotoCel
13 14 15
are wired wrong - N.C. or N.O. depending on which
photocells are used (see below) or sensor is bad etc. and
must be corrected. When all LEDs are ON that should be ON, proceed to next step.
POWER
24V
GND
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
BATTERY
IN USE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO GND
RADIO SIG.
GND
Example shows that sensors
are DETECTED on inputs
Edge 2 and Photo Cell.
MATRIX 1
BATTERY
BACK-UP MODE
PRIMARY
GATE
LEAVE
CLOSED
LEAVE
OPEN
MADE in USA
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
MOTOR MOTION
EXIT
ON
EXIT
CENTER
GATE
TAMPER
SAFETY
OFF
Tamper NO
COM
GND
Tamper IN
CENTER
PHOTOCELL
UL
SAFETY
MIN
EDGE 1
MAX
OFF
ENTRAP
EDGE 2
CLOSEE TIMER
CLOSE
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
POSITION
CORDER
RECORDER
12VDC
GND
OBD PORT
BLACK BOX
24VDC
OPEN
STOP
MAX
GATE SPEED
MIN
CLOSE
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
UL ALARM 12V
ALARM RET
RESET
GND
OPEN
COM
CLOSE
GATE
STATUS
BATTERY
IN USE
POWER
24V
GND
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO GND
GND
RADIO SIG.
5. Press STOP button again within 5 min. to learn sensors and
OPEN STOP
end learn mode, beeping stops.
Wired Inputs are now MONITORED.
If STOP button is not pressed within 5 min. learn mode terminates.
If no sensors are detected then factory default setting (Edge 2 and
UL 325 2016 Compliant MONITORED Normally Closed Entrapment Protection Devices:
Normally Closed Definition: When Power is off, relay contacts are OPEN. When Power is on, relay contacts are CLOSED.
Photo Cells:
Model RG Miller Edge Reflecti-GUARD Reflective-Beam Type (Normally Closed)
Model PG Miller Edge Prime-GUARD Thru-Beam Type with battery operated transmitter (Normally Closed)
Model EMX-IRB-MON EMX Thru-Beam Type (Normally Closed)
Model EMX-IRB-RET EMX Reflective-Beam Type (MUST be wired to Normally Open)
Model E3K-R10K4-NR OMRON Photo Electric Sensor Reflective-Beam Type (MUST be wired to Normally Open) will work with 12V
Model 60-2728-1 Allen Bradley Reflective-Beam Type (MUST be wired to Normally Open)
Direct-wired 10K Sensing Edge:
Model 10K Sensing Edge with GEM-104 Module Miller Edge (Normally Closed)
MAX 10K Mini Edge Maximum Controls (Normally Closed) Requires a Miller Edge GEM-104 module
MAX 10K Edge 1 Maximum Controls (Normally Closed) Requires a Miller Edge GEM-104 module
Sensing Edge Wireless Transmitter/Receiver:
Model MGL-K20 Miller Edge Monitored Gate Link Transmitter and Receiver
18
Wiring operator
input ac power
AC IN Power LED
Wire input AC power wire to the MAX Megatron Toroid box as shown.
Choose either 115V or 230V setting on input AC power selector switch.
NOTE: AC power wire is required for EACH gate operator
when using dual gate operators.
AC
230
V
IN
11
5
Input AC Power
Selector Switch
MA
X
CAUTION: Make sure circuit
breaker is OFF from incoming
AC input wire BEFORE wiring!
Me
Ba
ck
Tor Meg of M
oid atr AX
Bo on
x
Se
le
Vo ct In
lt
11 age put
5
23 VAC
0V or
AC
ga
tro
nT
or
o
id
ww
w.M
ax
.U
S.c
om
M
M AX
To eg
ro at
id ro
Bo n
x
CAUTION: If power selector
switch is set for 115V but
input power is actually 230 V,
7 Amp Fuse will blow.
n
tio
otec
d pr e
ue ith th
ntin w
co only se.
or
fu
s
: F ace of
s
pa le
ING repl ting
ne ntre e
RN fire, d ra
ur
po n cofusibl
WA nst an
s
ai pe
NT: ectio un
ag e ty
ME ot ser tique
m
SE la pr utili éris
sa
ct
TIS tre ie,
ER et nd cara
AV prom ince et
m d’
co es type
qu es
ris êm .
m es
de inal
m
no
Input AC Power Options
7 Amp Fuse
Single Phase 115VAC Only
AC Power
Gang Box
mp
7 ASE
x
ma
FU
On ER
3A
W
AC
PO
5V
11
Off
115VAC
Power
Terminal
DANGER
Set to 115V
!
Power Terminal
Line (Black)
115 OR 230VAC
Power Wire
GH E
HI AG
LT ect
VO connefore
DO NOT TURN POWER
ON AT THIS TIME.
HIGH VOLTAGE!
115V
NG
NI
AR
W
dis r b u
we g
po icin
rv
se
nit
Line (Black)
Neutral (White)
Neutral (White)
Chassis (Green)
Chassis (Green)
Single Phase 230VAC Only
IMPORTANT NOTE: Make sure there are NO exposed
bare wires at the power terminal connection.
ll
Ed
ge
Ph
oto
Ce
MA
1
2
SW
Lim
it
LT
g
Jo g RT
Jo GND 1
ge 2
Ed ge o
Ed ot l
Ph el
C
RI JO
G G
H
T
JO
LE G
FT
X
ON
MAD
TIC
MA
TO
AU
N
OPE
LEFT
I
ANT TE
LGA
TAI
OFF
G
MA K
LOC
COM
NC
1.5S
NO
per
Tam COM
GND
IN
per
Tam
OFF
N
OPEHT
RIG
E
GAT
PER
TAM
LS
RO
E
LEAVED OPEN
CLOS
1 TIME
E
LEAV
OPEN
NT
CO
SE
/CLO
EN
TER
OP
CEN
T
EXI
OR
MOT TS
INPU
E
Y
TER DE
BAT P MO
K-U
BAC
1
in USA
SAF
ETY
PHO
T
LIMICH
ERYSWIT
BATT K
PAC
TIO
MO
ER
12V
RM
ALA RET
ET
UL ALARM
RES
GND
CLO
SE
TIM
POR
OBDCK BOX
BLA
N
T
LIMITCH
SWI INE
ON-L
OR
MOT INE
SEC
ON-L
S.c
om
E
GAT
TUS
STA
Y
TER
BAT USE
IN
POW
ER
GATE
(+)
GND
(-)
ARY
PRIM
GATE
GND
STRIKE
GND
/ RDR
KEYPAD
GND
L
PHOTOCEL
C
24VD
x.U
TY
ITIVI
SENS
RSE
LOAD
REVE
OVER
/
OR
CH
MOT
T SWITPING
LIMI P SLIP
NO
CLAM
MIN
MAX
GND
ww
w.
Ma
FIRE DEPT
GND
MAX OPEN
GND
To
ro
id
RADIO GND
n
OPE
ED
X
MA E SPE
GAT
12VD
GND
ga
tro
SE
P
STO
TIAL
PAR N
OPE
N
ITIO
POSORDER
REC
T
RADIO SIG.
115
Me
CLO
ER
C
OPEN
STOP
CLOSE
COM
GATE DISABLE
X
TRI
MA ARD
BO
X
N
OPE
COM
SE
CLO
MO
MAX
MIN OFF
TY
SAFE
(+)
GND
(-)
RM
is
ass d
Ch roun
G
MA
E1
E2
EDG
G
PLU
ID OR
ERR
RAP
N
TOR
CENT
ID
G
PLU
IN
Se
lec
Vo t Inp
ltag
115 e ut
230VAC
VA or
C
ELL
EDG
ENT
ALA
RS-485 (+) RS-485 (-) GND PWR 24V -
AC
TOC
UL
ON
EXIT
24V
GND
M
A
4
3
LE
D
Se ER
ns D
itiv
ity
5
15 16
14
12
13
D
ER
O M
ve ot
rL or
oa
d
CK
GLO
MA AY 2Sec
DEL ec
RY
MA
PRI E
GAT
IX
TR
MA
Proper grounding of this gate operator is a
WARNING
requirement for LIGHTNING PROTECTION
connect chassis
in lightning prone areas. To be effective,
to ground rod for
ground connections should be made with a
lightning protection
minimum 12 AWG, 600 volt insulated wire
to a ground point within 10 feet of the gate operator. The ground
point must be at an electrical panel, a metallic cold water pipe that
runs in the earth, or a grounding rod.
LINE
ON-
Ed
ge
TR
IX
UL
En
tra
M
ot
or M
C
p Co
-2
PO
nt 0
ro 0
W
lle
ER
r
Any of the Chassis Grounds can be used. They are located next to
the gear reducer. DO NOT remove any existing green ground wires.
r In
Operator MUST be Properly GROUNDED
Ground
within 10 ft
of operator.
we
230V
Po
Set to 230V
R
TO
MO
230VAC
-7
X BCule
MAery Mod
Batt
BA
TT
ER
IN Y
Bat
E
tery
e
tag
Vol F
1/2
lace
Rep ery
OFF Batt
ON/ ery
Batt
T
TES
ery
Batt
ery
Batt r
Erro
IN
Grounding Rod
NOTE: Consult city codes for AC line wiring.
Beware of existing underground services.
19
Wiring operator
low voltage remote power supply kit - optional
A MAX Magic Box Kit (sold separately) is required to remotely install a Remote Toroid 15 Amp box at the AC power source.
Plug in Remote Toroid 15 Amp connector to Power In at MAX Magic Box. Wire input AC power to the Toroid 15 Amp box.
Choose either 115V or 230V setting on input AC power selector switch. Run 24V low voltage wires (not included) from the
MAX Magic Box connection to the gate operator and wire to POWER/SOLAR IN connector (Polarity Matters!).
Remove the Remote Toroid 15 Amp connector from the BC-7 battery module POWER/SOLAR IN port. Plug the Magic Box
POWER/SOLAR IN connector into the POWER/SOLAR IN port.
At MAX Magic Box
NOTE: A MAX Magic Box kit is required for EACH gate operator
when using dual gate operators.
DO NOT TURN POWER
ON AT THIS TIME.
Ground
within 10 ft
of Box
DANGER
HIGH VOLTAGE!
Tor Rem
Po
oi ot
we
Co d 15 e
nne Am
r
cto p
r
s+
IMPORTANT NOTE: Maximum Control’s remote
power supply technology does NOT utilize the
battery power from the MAX BC-7 Battery
Module during NORMAL gate operation.
Battery power is reserved for back-up power
ONLY when an AC power failure occurs. As a
result, battery life is NOT shortened.
This low voltage system can CONTINUOUSLY
cycle the gate during NORMAL gate operation,
perfect for high traffic gate applications.
20
Pos +
ww
w.M
T
O
T MO
R T
O O
L R
L
E
R
om
N
S.c
O
.U
C
ax
A
R
POWER/SOLAR IN
Connector
(Included in kit).
P
O
W
IN ER
POWER/SOLAR IN
Port
PO
WE
R/S
IN
OL
AR
-7
BCule
AX Mod
Y
r
E
R
/S
IN O
L
CAUTION: MAKE SURE CIRCUIT
BREAKER IS OFF AT POWER
SOURCE BEFORE WIRING
115
VA
Inp 230 VC or
ut AC
AC
Po
we
E
IN R
NOTE: Consult city codes for AC line wiring.
M tery
Bat
BA
TT
ER
IN Y
Ba
GND
ge
lta
Vo F
ry
tte /2
1
E
lace
Rep ry
FF Batte
/O
ON tery
Bat
ST
TE ry
te
tery
Bat rror
E
IN
Bat
C-7
X B odule
A
M M
ery
att
Polarity Matters!
2
in 4V L
Co ow
ndu Vo
it t lta
o G ge
ate Wir
Op e
era
tor
at
P ter
ac y
k
CAUTION: If power selector switch is
set for 115V but input power is actually
230 V, 7 Amp Fuse will blow.
B
Input AC Power Selector Switch
IMPORTANT: MAX Magic Box and Gate Operator
MUST EACH be Properly GROUNDED. Proper
grounding is a requirement for LIGHTNING
PROTECTION in lightning prone areas. To be
effective, ground connections should be made
with a minimum 12 AWG, 600 volt insulated
wire to a ground point within 10 feet of the MAX
Magic Box and gate operator. The ground point
must be at an electrical panel, a metallic cold
water pipe that runs in the earth, or a grounding
rod.
NOTE: Beware of existing underground services.
T
T
ut
Inp
MAX Magic Box MUST be
Properly GROUNDED
A
er
ow
P
AC
To Operator
24 VDC
wa
VOrran
if IDEty
l
RE abe D
MO l is
VE
D
V
24es
r
Wi WG
A
10 imum
n
i
M
O
W
ox
High Voltage
le
c
11 t In
5V pu
AC t
or Vol
23 tag
0V e
AC :
230V
Se
Po
d
P
un
pB
Grounding Rod
Low Voltage
Am
Input Power
Power Terminal
Wires
Line (Black)
Neutral (White)
Chassis (Green)
PO ON
OF WER
F
ow nn
se er ect
rvic be
ing fore
un
it
15
AC
W
AR
NI
NG
!
H
VO IGH
LT
dis A
p co GE
Gro
IN
id
In GN
D
B
SA
U
in
e
ad
M
Tor
o
7 A FUSE
MP
te
IMPO
R
M
mo
TANT
co
“BA nnect to
TT
befo ERY IN
”
re u
se
PO AX
WE
R S PS-2
UP
PLY 4
Re
B
At Gate Operator
Wiring operator
solar power connection - optional
Refer to Solar application guide.
R
WE
IN
w
w
w
.M
ax
.
U
S
.c
om
PO
R
TO R
MO LLE
TO TRO
N
CO
ry
tte
Ba Pack
AR
PO
WE
PO
R/S
Pos + Red
Polarity Matters!
IN
OL
AR
7
CX Bodule
MttAery M
Y
ER
IN
TT
BA
BA
TT
ER
IN Y
Ba
ge
lta
Vo F
ry
tte /2
Ba
1
E
ce
pla
Re ery
FF Batt
/O
ON ery
tt
Ba
ST
TE ry
tte
ry
tte
Ba rror
E
IN
Ba
IMPO
RT
ANT
co
“BA nnect to
TT
befo ERY IN
”
re u
se
NOTE: Cover solar panel from
sunlight BEFORE wiring plug to
solar panel to prevent a shock
from occurring.
OL
IN
R/S
WE
Connect to
POWER/SOLAR
IN
GND Black
MAX BC-7 Battery Module
Max Solar
Power Kit
(Sold separately)
(Approximately 450 cycles using only battery power)
21
Wiring operator
secondary operator to matrix 1
Primary
Gate Operator
Matrix 1
Unplug 4-Pin plug from the bottom of the
MAX MC-200 motor controller and connect
RS-485 wires as shown below.
MATRIX 1
BATTERY
BACK-UP MODE
PRIMARY
GATE
LEAVE
CLOSED
OPEN
LEFT
OPEN
1 TIME
LEAVE
OPEN
MADE in USA
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
ANTI
TAILGATE
EXIT
CENTER
SAFETY
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
OFF
D
R ity
E itiv
ns
5
CENTER
15 16
X
A ON
M LED
LEJOG
FT
PHOTOCELL
JO
RIGH
G
T
OFF
1
it
ge
Ed
Lim
Mot
or
2
UL
SW
p
tra
En
ge
Ed
Co
PO
ntro
WER
lle
EDGE 2
ENTRAP
ll
00
Ce
oto
Ph
PARTIAL
OPEN
-2
C
M
C-2
0
EDGE 1
MAX
MIN
CLOSE TIMER
-LIN
E
IX
TR
ON
MA
MA
XM
UL
SAFETY
Jo
Jo g
g LT
R
E GN T
E dg D
d e
P ge 1
h
C oto 2
ell
14
4 3
12
13
NOTE: The Alarm Shut-Off is
located on the Primary gate
operator ONLY. There is NO
alarm shut-off button on the
secondary gate operator.
ON
EXIT
Ov Mot
erLo or
ad
D
Se
ER
r
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
0
OPEN
MA
BOTRIX
AR
D
RS-485 (+) RS-485 (-) GND PWR 24V -
POSITION
RECORDER
12VDC
GND
STOP
MAX
GATE SPEED
not used not used GND PWR 12V -
OBD PORT
BLACK BOX
MIN
24VDC
CLOSE
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
UL ALARM 12V
ALARM RET
RESET
GND
BATTERY
IN USE
RM
TOR
INP
UTS
wer
R
In
LIM
SWI IT
TCH
BAT
MO
Po
TO
MO
L
O
/S
R
E IN
A
p
7 Am
SE
max
FU
On ER
3A
W
AC
PO
5V
11
Off
B
R
w
Y
R
E
T
T
A IN
w
ax
.M
w
om
.c
S
.U
ery
att k
B ac
P
Vo
1/2
lta
ge
R
E
W
O
P IN
R
O
T R
O E
M LL
O
T RO
T
N
O
C
E
Secondary
Gate Operator
ry
P
MC
To ER IN
OW
LIMIT
SWITCH
ON-LINE
F
ON
/OF
Ba F
tte
ry Repla
Ba ce
tte
ry
MAX
Ba
tte
ry
TE
ST
Ba
tte
ry
BC
Mo
-7
du
le
Ba
tte
ry
Err IN
or
MC k
To Pac
ry
te
Bat
Secondary
Operator
MAX MC-200
BATTERY
PACK
LIMIT
SWITCH
ALARM
3 Wires to Matrix 1
22
MOTOR
INPUTS
Secondary
Power In
3 Wires to Matrix 1
MOTOR
GND -
not used -
not used -
PWR 12V -
RS-485 (+) RS-485 (-) GND PWR 24V -
NO 24V
to
Matrix 1
PRIMARY
GATE
SEC
GATE
(+)
GND
(-)
(+)
GND
(-)
MOTOR
ON-LINE
(NO Matrix 1)
Connect (3) three RS-485 wires from the
SECONDARY operator’s MAX MC-200 motor
controller to the Matrix 1 - SEC GATE.
• Pos (+) to Pos (+)
• Neg (-) to Neg (-)
• Gnd to Gnd
• DO NOT connect PWR 24V.
22 AWG Min. 3-conductor
twisted pair, shielded cable
Primary
24V
GND
(+)
GND
(-)
POWER
SEC
GATE
(+)
GND
(-)
FIRE DEPT
GND
TER
PAC Y
K
RADIO SIG.
RADIO GND
ALA
MOTOR
ON-LINE
PRIMARY
GATE
n
tio
tec
pro
ed the
nu th
nti ly wi
r co on fuse.
Fo e
s
G: lac of
pa e les
IN rep ing
ne
RN fire, d rat
ur contr ible
WA st e an
: po tion fus
ain
ag typ MENT tec er uniques
me
SE la proutilis térist
sa
,
TIS re
ER ett die carac
AV rom ncene et
mp d’i typ
co es s
qu
ris me .
mê
de nales
mi
no
W
O
P
tte
4-Pin Plug
OPEN
COM
CLOSE
GATE
STATUS
GND
4-Pin Plug
Ba
MATRIX
BOARD
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
Wiring operator
turn on/off operator power
Operator should have Input AC power wired to Toroid Box, 24V & RS-485 wired between Matrix 1 and MC-200.
TURN POWER ON. Certain LEDs should normally turn ON accordingly:
A Located on back of box.
DO NOT CYCLE GATE OPERATOR
AT THIS TIME
MAX Megatron Toroid Box
A AC IN LED:
Normal - Turns ON.
Error - Not ON. Check AC power.
7 Amp Fuse blown. Replace fuse.
Input AC selector switch MUST be set to CORRECT input AC power.
Battery power automatically turns ON.
n
tio
ec
prot e
ed th th
ntinuly wi .
r co on fuse
s
: Fo ce of
Turn AC Power
Switch ON
M
o
P
L
U
e
ell
C
E
dg
P
ho
to
1
e
M
3
2
C
1
R
TO
MO
D
r In
we
Po
-
RS-485 (+) RS-485 (-) GND PWR 24V -
Matrix 1
PRIMARY
GATE
LEAVE
OPEN
OPEN
LEFT
OPEN
1 TIME
H
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
MAG
LOCK
2Sec
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
ON
Limit SW On-Line LED:
Normal - Turns ON.
Error - Not ON. Check LIMIT SWITCH plug.
SW
RM
LEAVE
CLOSED
EXIT
Matrix On-Line LED:
Normal - Turns ON.
Error - Not ON. Check RS-485 wiring to Matrix 1.
ALA
BATTERY
BACK-UP MODE
MADE in USA
T
US s.
3 Mnsor 3 : T be be
&
n
S
2 & se
ts ITOR ts 2 rs MU ey caST be
InpuON inpu enso RE th MU
M RN
n
ts
D S EFOinpu
to
A
l ca
RE B
LE
Cel
to
To NITOinputs used
-
GND PWR 12V -
MATRIX 1
E
dg
2
S
W
Lim
it
GND Edge 1
Jog LT Jog RT -
A
M
6
15 1
14
12
13
O M
ve o
rL tor
oa
d
D
E
MC-200 Swing
N:
IX
TR
MA
B POWER LED:
Normal - Turns ON.
Error - Not ON. Check POWER IN plug on bottom of MC-200.
D
un
un
O to
P
Pho 3.
1.Mired Any
d/or 2 or STO 1
w ned.
e an put N & rix .
d.
learpere Edg er in OPE Mat gins
be
jum ersing eith the e onode
ev d to OLD e timn m
2.R wire d H sam lear
be an the ard,
N
ress at he MOTIO
3.P ttonsep is TOR
MO
bu be
E
til
OS
ted
un
CL
ca
P . indi
STO 5 min
ed
r
EN
tect ON
de
OP sts fo
ch L be
e la
r ea WIL
mod
N fo Ds al
arn ing. O LE du
in.
Le ep L be 00. hen
5m
w
be
-2
in e,
by s WIL MC 00s
with mod
D on C-2 .
n
n
4.LEnsorTH Me used agai lear
se BO ar tton end
s
.
for ator P bus and
D
er
RE
op STOnsor
ITO
ress n seops. ON
P
5. lear g st w M
to in e no
ep
be ts ar
Inpu
LE
D
O
N
X
ity
iv
5
4
3
en
E
sit
R
D
J
LE OG
F
T
1
ns.
ctio .
stru tion
n in stalla
llatio d’in
e
sta
e in notic
d
Se
ore
on
ir la
o
ti
nit g
IO N: V
r
tec
Mo ersin
UT
ro es 1 o
v
CA NTIO
t P lin GE
Re e
en ide ED
TE
g
AT
Ed
pm Gu ed ton.
ir
tra or
En ens be wfunctio (N.C.)ach
OR
e tors
S UST OT
D
d
E , to
ore
r M L N LOSNLY opera
nit
C O
l
nso IL
Mo to
LY rs dua
se r W
n
o
• Aperato RMALsensowhen
Ph
ll ca
o
ll
Ce
NO ED 00
to
Ce
ire OR C-2
ho .
r P puts to
• WONITtor’s M
d/o In sed
M ra .
an e 3
u
e
op used dge of th T be
E
.
d
GND
are ing ANY MUS sors
se
rs
V sen
eu
eve d to 12
ain
Tb
• Re wire PWRORED T rem ur.
US
b
VM
00 NIT MUS ill occ
n
12
w
C-2 MO
tio
ts
WR
tec
• Mower inpur fault
0P
D o
p
pro V
-20
SE ED
nt 12
R
MC
NU ER
me WR
TO
p
U
P
a P
• UM
MO UTS
ntr 00
J
r e -2
INP
RY
we MC
TE
po ith
BAT CK
LY w
PA
IT
ON sors
M
LI CH
n
IT
se
1
R
2
MAX MC-200 Motor Controller
B
n
tio
tec
ro r
t P pe
en jum
pm UST
”
tra : M
ED
En ts puts
RN
3 Inpued in
EA
“L
2
us
be
Edge 2
Photo Cell
R JO
IG G
H
T
J
Jo og L
g
T
E G RT
E dg N D
P dge e 1
Ce hoto 2
ll
S
O A
N TR
-L IX
IN
E
C
E t
ntr o
ap r C
M
C
-
mp
7 ASE
max
FU
On ER
3A
W
AC
PO
5V
11
Off
on 2
tr 0
O
oll 0
W
er
E
R
1
pa les
NG pla g
ne ntre le
NI e, re ratin
ur
fir d
po n cofusib
WAR st e an
T: tio
s
ain
EN otec un ue
ag e typ
m
EMla pr iliser ristiq
sa
, ut cté
TISS tre
ER et die cara
AV prom ncene et
m d’i
co es typ
qu es
ris êm .
m
de inales
m
no
EXIT
CENTER
GATE
TAMPER
SAFETY
OFF
Tamper NO
COM
GND
Tamper IN
E POWER LED:
Normal - Turns ON.
Error - Not ON. Check 24V wiring from MC-200 Primary.
F
Normal - Turns ON.
Error - Not ON. Check RS-485 wiring to Primary MC-200.
CENTER
PHOTOCELL
UL
SAFETY
3
EDGE 1
MAX
MIN
OFF
EDGE 2
ENTRAP
CLOSE TIMER
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
OPEN
12VDC
GND
MAX
GATE SPEED
OBD PORT
BLACK BOX
24VDC
MIN
REVERSE SENSITIVITY
LIMIT
SWITCH
ON-LINE
MOTOR
ON-LINE
PRIMARY
GATE
SEC
GATE
(+)
GND
(-)
F
G
GATE
STATUS
OPEN
COM
CLOSE
I
BATTERY
IN USE
POWER
E
Limit SW On-Line PRIMARY LED:
Normal - Turns ON.
H
MOTOR OVERLOAD
(+)
GND
(-)
FIRE DEPT
GND
MAX OPEN
GND
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
G
RADIO GND
CLOSE
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
GND
RADIO SIG.
STOP
OPEN
STOP
CLOSE
COM
GATE DISABLE
POSITION
RECORDER
UL ALARM 12V
ALARM RET
RESET
GND
24V
GND
PARTIAL
OPEN
Motor On-Line PRIMARY LED:
PRIMARY GATE OPEN RIGHT OPEN LEFT LED:
Normal - Turns ON either LED according to switch setting.
Error - Not ON. Check LIMIT SWITCH plug on bottom of MC-200.
I
BATTERY IN USE LED:
om
.c
B
at
P ter
ac y
k
C
S
MAX BC-7 Battery Module
E
R
/S
IN O
L
A
R
w
w
w
.M
ax
.U
T
O O
N M
T O
R T
O O
L R
L
E
R
P
O
W
IN ER
Normal - Not ON.
Error - Flashes on and off. Battery not plugged in to BATTERY IN port on
BC-7 Battery Module.
R
IMPO
4
TANT
co
“BAT nnect to
TE
befo RY IN
re us ”
e
C-7
e
X Bodul
MAry M
O
W
A
T
T
E
IN R
Y
P
/SO
IN LAR
B
PO
WE
R
BA
TT
ER
IN Y
tte
Ba
Ba
ge
lta
Vo F
ry
tte 2
1/
E
J
lace
Rep ry
FF Batte
/O
ON ry
tte
Ba
ST
TE ry
tte
Ba
ry
tte
Ba ror
Er
IN
K
J BATTERY VOLTAGE LEDs:
Normal - 3 LEDs turn ON - Fully charged batteries.
Batteries need charging - LEDs will turn on in sequence until batteries are
fully charged. Batteries are NOT necessary when AC power is available.
K BATTERY IN ERROR LED:
Normal - Not ON.
Error - Turns ON. Battery not plugged in to BATTERY IN port.
To turn OFF ALL POWER:
1. Turn OFF AC POWER Switch on MAX Megatron Toroid Box. Battery power remains ON.
2. WAIT for 15 seconds.
3. Press and HOLD (approx. 5 seconds) the RED ON/OFF BATTERY button
until MAX BC-7 LEDs turn ON, then release button. LEDs will turn OFF.
23
matrix 1
matrix 1 Overview
1 Battery Back-Up Mode - Page 26
2 Primary Gate - Page 26
MATRIX 1
3 Maglock - Page 29
4 Gate Tamper - Page 30
MATRIX 1
PRIMARY
GATE
BATTERY
BACK-UP MODE
5 In-Ground Loop Connection - Page 29
1
LEAVE
CLOSED
LEAVE
OPEN
MADE in USA
6 Anti Tailgate - Page 27
OPEN
LEFT
OPEN
1 TIME
ANTI
TAILGATE
9 Close Timer - Page 26
EXIT
CENTER
EXIT
5
4
Tamper NO
COM
GND
Tamper IN
PHOTOCELL
8
9
UL
SAFETY
MIN
13 Partial Open - Page 31
EDGE 1
MAX
OFF
EDGE 2
ENTRAP
CLOSE TIMER
PARTIAL
OPEN
14
13
17 ERD & Motor Overload LEDs - Page 33
POSITION
RECORDER
12VDC
GND
OBD PORT
BLACK BOX
MAX
15
LIMIT
SWITCH
ON-LINE
MOTOR
ON-LINE
PRIMARY
GATE
SEC
GATE
GATE
STATUS
OPEN
COM
CLOSE
18
BATTERY
IN USE
POWER
24 OPEN/STOP/CLOSE Connection - Page 32
19
External Alarm Reset Connection - Page 32
20
21
22
23
24
25
26
25 Gate Disable - Page 31
26 Matrix 1 Power - Page 33
MATRIX 1 Back
27 Battery in Use - Page 33
B Single Pass Anti-Tailgate - Page 27
C Radio Safety Pause - Page 29
OFF
ON
A Gate in Motion Alarms - Page 28
Mode 0
OFF
A
Single Pass Anti-Tailgate
B
ON When turned “ON”; After a vehicle clears the Safety Loop, a closing
gate will PAUSE if a second vehicle attempts to tailgate. The second
vehicle must then back off the safety loop for the gate to continue
closing. A new radio signal will open the gate.
ON
Mode 1
OFF
Gate in Motion Alarms
Mode 0
ON Motion Alarm sounds before gate moves and continues until gate stops
OFF Motion Alarms OFF
Mode 1
ON Beeper Alert sounds in Battery Back-Up Mode while gate is in motion
OFF Beeper Alert OFF
Radio Safety Pause
OFF
ON
C
When turned "ON" a moving gate will pause if a radio input signal is
received. The next radio signal causes the gate to continue in the
original direction.
WWW.Max.US.com
24
11
17
MOTOR OVERLOAD
(+)
GND
(-)
23 Operators Communication LEDs - Page 22 & 33
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
22 Close direction Photocell (N.O.) - Page 25 & 32
FIRE DEPT
GND
MAX OPEN
GND
RADIO GND
RADIO SIG.
21 Normal Opening Devices - Page 25
CLOSE
NO LIMIT SWITCH /
CLAMP SLIPPING
16
20 Emergency Vehicle/Max Open Inputs - Page 30
UL ALARM 12V
ALARM RET
RESET
GND
REVERSE SENSITIVITY
MIN
24VDC
GND
STOP
OPEN
MAX
GATE SPEED
ID PLUG
ERROR
24V
GND
16 Selectable Gate Speed Control - Page 26
12
10
MOTOR MOTION
ID
PLUG
OPEN
STOP
CLOSE
COM
GATE DISABLE
10
(+)
GND
(-)
14 Stop Button (Alarm Shut-Off) - Page 30, 32 & 42
matrix 1
COM
NC
7
CENTER
12 Radio Power - Page 28
19 Radio Relay - Page 28
MAG
LOCK
2Sec
GATE
TAMPER
SAFETY
6 OFF
ON
10 ID Plug & ID Plug Error LED - Page 30
18 Gate Status - Page 32
OFF 1.5Sec
AUTOMATIC OPEN/CLOSE CONTROLS
8 UL Entrapment LEDs - Page 30
15 OBD Port Black Box - Page 28
MAGLOCK
DELAY
OPEN
RIGHT
3
7 Loop Detectors - Page 29
11 UL Alarm / Alarm Reset Input - Page 30, 32 & 42
2
MADE IN USA
27
matrix 1
ON
wiring Overview
1
3
4
5
6
7
I
8
480.
DE
FL 968.
5
EC
Loop Detectors
See page 29.
S
Lo afety
op
MATRIX 1
BATTERY
BACK-UP MODE
oo er
p
2
800
A1
LMS
N
SE
R
TE
ME
TO
EC
FL
DE
NS
SE
WER
T
EC
I
DET ED
PO
T
SE
RE
OPEN
LEFT
OPEN
1 TIME
OFF 1.5Sec
MAG
LOCK
2Sec
COM
NC
EXIT
ON
EXIT
CENTER
GATE
TAMPER
SAFETY
OFF
PHOTOCELL
UL
SAFETY
PARTIAL
OPEN
ID
PLUG
POSITION
RECORDER
12VDC
250 mA Max.
GND
OBD PORT
BLACK BOX
24VDC
OPEN
STOP
MAX
GATE SPEED
CLOSE
MOTOR OVERLOAD
MIN
OPEN
COM
CLOSE
GATE
STATUS
NO LIMIT SWITCH /
CLAMP SLIPPING
LIMIT
SWITCH
ON-LINE
MOTOR
ON-LINE
PRIMARY
GATE
SEC
GATE
BATTERY
IN USE
OPEN
STOP
CLOSE
COM
GATE DISABLE
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
See page 32.
REVERSE SENSITIVITY
MAX
RADIO GND
RADIO SIG.
Strobe Light
12VDC
250mA Max
UL ALARM 12V
ALARM RET
RESET
GND
GND
Normal
Opening
Device
ID Plug Error LED. See page 30.
EN
POWER
ire o
3-WRadi
TE
GA
Gate Status:
See page 32.
TE
GA
OP
OS
CL
ED
24V Power for Matrix 1 from
Primary operator ONLY. See page 33.
ire o
4-WRadi
ON
See page 28.
F
OF
Security Device
Gate Disable
Switch or Timer
See page 31.
Stop
(N.O.)
Emergency/Security Devices
T
3-Button
SE
RE
to
Station
See page 32. External Alarm
Reset Button
Normal
See page 32.
Opening
Device
Security Device
(N.O.)
See page 30.
S
ES
PR
MAX OPEN
(Overrides gate
disable switch)
Normal Opening Devices
Dry Contact (N.O.)
RS-485
External
Open/Close
Key Switch
with Dual
Gates
See page 34.
Normally Closed Photocell
See page 13 &17.
M
C C
on - 2
tr 0
oll 0
er
UL 325
Type B1
M
oto
a r
3
2
AR
M
ell
E
dg
ho
to
C
P
1
tio
dg
E
W
2
e
M
O
N
M
A
1
k
P
R
Lin
te
N
LE
AR
LE
D
SW
AL
-
Power
tec
n
S
ro r
t P pe
en jum
pm UST
”
tra M
ED
En ts: puts
RN
3 Inpued in
EA
“L
us
T be
un
US s.
3 Mnsor 3 : be be
2 & R se 2 & MUST can be
ts
ts
Lim
it
2
Edge 2
Photo Cell
GND Edge 1
Jog LT Jog RT -
J
L E OG
F
T
E
T
U
TP
U CT
O LE
SE
1
CH
2
M C.
CO N.
P/ K
10 M
C.
CO N.
P/ K
10
ER
W
2
PO
CH
CH
S
U
AT
ST
ER
MC-200 Swing
IX
TR
MA
-
Wireless
Sensing Edge
Radio Receiver
Refer to wireless
manual for more
information.
Normally
Closed
10K Sensing Edge
wiring, See
page 13 &17.
16
15
RS-485 (+) RS-485 (-) GND PWR 24V -
Normally Open Closing Photocell ONLY.
See page 32 (Typically Retro-fit).
NOT UL 325 entrapment protection.
1
CH
Photocell (N.O.)
W
PO
Separate power
for Devices.
M
M onit
G o
L-R re
20 d G
a
Keypad
.
ns
ctio
stru tion.
n in stalla
12 13
tio
alla e d’in
inst
tic
d
See la no
n
ore
N: Voir
tio
nit ng
c
IO
:
N
Mo ersi
UT
rote es E 1 or
CA NTIO
t P lin
Rev e
en ide EDG
TE
g
AT
Ed
pm Gu d ton.
ire
tra or
En ens be wfunctio (N.C.) ch
OR
ea ors
S UST OT
D
red
SE , to at
M N
ito
or ILL CLO NLY oper
n
ns
Y s O dual
Mo to
se or W
or n
n
o
ns
• A erat RMALL
l ca
Ph l
se whe
op
Cel
NO ED 00
to
Cel
ire OR C-2
Phoputs. to
• WONITor’s M
d/or In
ed
M at .
an e 3
us
er
op used dge of th T be
E
GND
ed
are sing ANY MUS ors.
us
er
V sens n
ev d to 12
ai
T be
• R wire PWRORED T remcur.
US
be 00
VM
NIT MUS ill oc
n
12
C-2 MO
tio
R
ts t w
• M wer inpu faul
PW
otec
po ED D or
t pr12V
-200
S E
R
MC
NU ER
menWR
TO
• U MP
MO TS
trap P
PU
en -200
JU
IN
Y
C
er
ER
w M
TT
po ith
BA CK
LY s w
PA
IT
ON or
M
LI CH
ns
IT
se
1
14
GND PWR 12V -
12 VDC OR 24 VDC
Photocell
Power
Card Reader
1
X
S E
en R
sit D
iv
ity
O M
ve o
rL tor
oa
d
5 4 3
R
D
ON = Obstruction
BLINKING = Fault
MON.
PWR
SAFETY
INPUT
R JO
IG G
H
T
UL 325
Type B2
GEM - 104
GEM-104
Key Switch
O A
N TR
-L IX
IN
E
10K Edge
Dry Contact
(N.O.)
LT
g T
Jo g R D
Jo GN e 1
2
dg e
E dg to
E ho ll
P e
C
e
U
L
P
E
ntr
p
Telephone Entry
E
R
Emergency OPEN
(Overrides gate
disable switch)
Secondary Operator
Connect to MC-200
See pages 22 & 33.
matrix 1
12 VDC
OR 24 VDC
Radio Power
ID PLUG
ERROR
MOTOR MOTION
(+)
GND
(-)
2200
ID Plug:
See page 30
Motion
Sensor
UL LED Indicators ONLY.
See page 30.
EDGE 2
ENTRAP
CLOSE TIMER
(+)
GND
(-)
MAX
MEGATRON
FAST
MAX
MEGATRON
2200
OFF
FAST
EDGE 1
MAX
MIN
MAX
MEGATRON
1400
Tamper NO
COM
GND
Tamper IN
CENTER
Safety Loops
Wired in series
Security
Camera
Gate Tamper:
See page 30.
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
1400
Power
MAGLOCK
DELAY
OPEN
RIGHT
24V
GND
Lo Exit
op
LEAVE
OPEN
MADE in USA
1
3
SW
4
ON 1 SW
5
6
ON ON 2
7
OF OF = Freque
8
OFF ONF = Low ncy
F
SW OF = Mediu
F Mediu mON 3
=
Lo
OF = Fa High m-Hi w
F
gh
SW = Fail Se
ON 4 SW il Sacure
ON ON 5 fe
OF OF = Outp
ut
OFF ONF = Pulse B
F
B sa on
SW OF = Pu
En
F = lseme as
try
ON 6
Lo on A
OF = 2
op Ex
Fa it
SWF = NoSeco
ult
ON 7
De nd De
OF = No lay lay
SWF = Infrmal
ini Pres
ON 8
te
Presence
OF = Se
F = ns
en
ce
No itivit
Se y Bo
nsiti os
vit t
y Bo
ost
PRIMARY
GATE
LEAVE
CLOSED
S
Lo afety
op
Maglock Connection:
Must be specifically
wired,
See page 29.
ON
= Op TO
64
= Inctim MET 07
= De reasum Se ER
cre e Se ns.
ase ns
D
PO INDI Sens.
ONWER CATO .
OF = No
RS
DEF= No rmal
ONTECT PowePowe
r r
OF = De
F=
2 Hz No tect
Lo Flash Detec
op
1 Fla Fa =Dela t
2 Fla sh ult y Tim
3 Flashes= Open ing
shes= Sh Lo
orted op
=25%
Both
ch Loop
Cu LED’sof Ind an
PW rrent Fla uctange
R
Lo sh
ce
PrevLED Flaop Faing=
iou sh ult
s Lo ing
op =
Fault
LE
O
W
In-Ground Loops
C
See page 29.
L ent
OPTIONS
2
ED
Tel:
ey T
s
TO
InpuONI inpu nsorRE th MUS
N
M
n
ts
D Se FO pu
to
AR
ll ca
RE BE in
LE
Ce
To NITOinputs used
oto
O to y un
Ph 3. OP
1.M red An
d/or or ST
wi ned.
an t 2 N & rix 1 .
d.
pu
learpere Edgeer in OPE Mat gins
be
g
jum rsin eith the e onode
ve d to LD e timn m
2.Re wire d HO sam lear
be s an the ard,
N
es at he MOTIO
3.Pr ttonsep is TOR
MO
bu be
E
til
OS
ted
un
CL
dica
OP . in
ST 5 min
ed
r
EN
tect N
de be O
OP sts fo
ch
ea ILL
e la
for W
mod
N Ds al
arn ing. O LE du
in.
Le ep L be200. en
5m
wh
be
by WIL MC- 0s
thin ode,
wi
20
Ds on C.
n nm
4.LEnsorTH Me used agai lear
se BO ar tton end
s bu d
r
or
fo at
D.
OP s an
er
RE
op s ST nsor
TO
es n se s. ONI
5.Pr lear g stop w M
to in e no
ep
be ts ar
pu
In
R
TO
MO
r In
we
Po
MC-200
Motor
Controller
page 17 &18
25
matrix 1
primary gate - open left / open right
Set the Primary gate operator with Primary Gate setting. Secondary operator will
automatically be set to the opposite opening direction as the primary gate operator
when using dual gates.
MATRIX 1
BATTERY
RY
ACK-UP MODE
BACK-UP
PRIMARY
GAT
GATE
LEAVE
CLOSED
LEAVE
OPEN
MADE in USA
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE
A
N/CLOSE CONTR
CONTROLS
ANTI
TAILGATE
EXIT
CENTER
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
EXIT
CENTER
PHOTOCELL
PRIMARY
GATE
OUTSIDE Property
EDGE 1
UL
SAFETY
EDGE 2
ENTRAP
CLOSE TIMER
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
PRIMARY
SECONDARY
OPEN
LEFT
OPEN
RIGHT
OPEN
POSITION
RECORDER
12VDC
GND
STOP
MAX
GATE SPEED
OBD PORT
BLACK BOX
CLOSE
REVERSE SENSITIVITY
MOTOR OVERLOAD
MIN
24VDC
UL ALARM 12V
ALARM RET
RESET
GND
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
OPEN
COM
CLOSE
GATE
STATUS
POWER
24V
GND
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
BATTERY
IN USE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO GND
RADIO SIG.
GND
INSIDE Property
OPEN RIGHT
LED turns ON for
MAX setting ONLY
MATRIX 1
PRIMARY
GATE
BATTERY
BACK-UP MODE
LEAVE
CLOSED
LEAVE
OPEN
MADE in USA
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
The Close Timer has 16 selectable settings for automatic gate close time.
Knob at OFF position: close timer OFF.
1st click clockwise - Knob at MIN position: 1/2 sec...
MIN
MAX
2nd click clockwise: 1 sec...
OFF
3rd click: 4 sec...
CLOSE TIMER
4th click: 8 sec...
5th click: 12 sec (4 sec increments for each successive click up to 60 sec MAX)
ANTI
TAILGATE
EXIT
ON
EXIT
CENTER
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
OFF
CENTER
PHOTOCELL
EDGE 1
UL
SAFETY
MIN
MAX
OFF
EDGE 2
ENTRAP
CLOSE TIMER
PARTIAL
P
OPEN
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
OPEN
POSITION
RECORDER
12VDC
GND
STOP
MAX
GATE SPEED
OBD PORT
BLACK BOX
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
MOTOR OVERLOAD
MIN
24VDC
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
OPEN
COM
CLOSE
GATE
STATUS
GND
BATTERY
IN USE
OPEN
STOP
CLOSE
COM
GATE DISABLE
POWER
24V
GND
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
RADIO SIG.
LIMIT
SWITCH
ON-LINE
FIRE DEPT
GND
MAX OPEN
GND
gate close timer
RADIO GND
OPEN LEFT
NOTE: 1/2 sec MIN position is recommended for High Traffic areas.
MATRIX 1
selectable gate speed control
OPEN
LEFT
OPEN
1 TIME
ANTI
TAILGATE
EXIT
MOTOR MOTION
ON
EXIT
CENTER
MAG
LOCK
COM
NC
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
OFF
PHOTOCELL
EDGE 1
UL
MIN
MAX
OFF
EDGE 2
ENTRAP
OPEN
STOP
MAX
CLOSE
PARTIAL
OPEN
ID
PLUG
REVERSE SENSITIVITY
GND
MOTOR OVERLOAD
OPEN
POSITION
RECORDER
12VDC
GATE SPEED
ID PLUG
ERROR
MOTOR MOTION
STOP
MAX
GATE SPEED
OBD PORT
BLACK BOX
24VDC
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
MOTOR OVERLOAD
MIN
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
OPEN
COM
CLOSE
GATE
STATUS
GND
SEC
GATE
POWER
24V
GND
MOTOR
ON
ON-LINE
PRIMARY
GATE
BATTERY
IN USE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
TRIKE
STRIKE
ND
GND
YPAD / RDR
KEYPAD
GND
D
PHOTOCELL
TOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
MAX
RADIO GND
NO LIMIT SWITCH /
CLAMP SLIPPING
(+)
GND
(-)
MIN
LED turns ON for
MAX setting ONLY
MATRIX
RIX 1
PRIMARY
GATE
BATTERY
BACK-UP MODE
DE
LEAVE
CLOSED
OPEN
LEFT
OPEN
1 TIME
LEAVE
OPEN
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC
AUT
MATIC OPEN/CLOSE
OPEN/C
CONTROLS
ANTI
TAILGATE
ON
EXIT
CENTER
GATE
TAMPER
SAFETY
OFF
Tamper NO
COM
GND
Tamper IN
PHOTOCELL
UL
SAFETY
EDGE 1
MAX
MIN
OFF
ENTRAP
EDGE 2
CLOSE TIMER
TIME
PARTIAL
OPEN
26
2Sec
CLOSE TIMER
LEAVE OPEN - The gate operator will continue to cycle the gate normally until the
battery power can no longer cycle the gate. When this happens, the gate will open
to OPEN position until power is restored, then gate will automatically close.
OPEN 1 TIME - The gate operator automatically OPENS gate and REMAINS in the
OPEN position. A open/close command or loop event is needed to close gate.
OFF 1.5Sec
AUTOMATIC OPEN/CLOSE CONTROLS
The Battery Back-Up Mode setting will determine how the gate operator will function during
an AC power failure. Gate operator with a full battery charge should cycle a 2000 lbs gate
(battery power ONLY) approximately 450 times.
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
POSITION
RECORDER
12VDC
LEAVE
OPEN
OPEN
STOP
MAX
GATE SPEED
MIN
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
OPEN
COM
CLOSE
GATE
STATUS
SEC
GATE
BATTERY
IN USE
POWER
24V
GND
MOTOR
ON-LINE
PRIMARY
GATE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
GND
FIRE DEPT
GND
MAX OPEN
GND
LEAVE
CLOSED
OBD PORT
BLACK BOX
24VDC
RADIO GND
BATTERY
BACK-UP MODE
GND
RADIO SIG.
LEAVE CLOSED - The gate operator will continue to cycle the gate normally until
the battery power can no longer cycle the gate. When this happens, the gate will
close if not already in the CLOSE position, where it will remain until power is
restored. Enough battery power is retained for a LIMITED time to operate
emergency vehicle entry (Using opening devices connected to FIRE DEPT and/or
MAX OPEN inputs to FULLY open gate).
MAGLOCK
DELAY
OPEN
RIGHT
(+)
GND
(-)
battery back-up mode
LEAVE
CLOSED
RADIO SIG.
The Gate Speed knob has 16 selectable settings to choose from.
MAX Megatron 1400/2200 speed varies approx. 11.5 sec to 20 sec.
MAX Megatron FAST speed of dual gates varies approx. 6 sec to 14 sec.
The speed will vary depending on the weight and length of the specific
gate(s). Make sure gate speed is appropriate for the size and length of
the gate(s).
NOTE: The Auto Gate Sync feature provides synchronous opening and
closing between bi-parting gates (dual gate operators).
PRIMARY
GATE
BATTERY
BACK-UP MODE
LEAVE
OPEN
MADE in USA
OPEN
1 TIME
FIRE DEPT/MAX OPEN Inputs
matrix 1
MATRIX 1
anti tailgate
BATTERY
BACK-UP MODE
PRIMARY
GATE
LEAVE
CLOSED
OPEN
LEFT
OPEN
1 TIME
LEAVE
OPEN
MADE in USA
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ON
CENTER
GATE
TAMPER
SAFETY
OFF
Tamper NO
COM
GND
Tamper IN
PHOTOCELL
EDGE 1
UL
SAFETY
MIN
MAX
OFF
EDGE 2
ENTRAP
CLOSE TIMER
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
OPEN
POSITION
RECORDER
12VDC
GND
STOP
MAX
GATE SPEED
OBD PORT
BLACK BOX
MIN
24VDC
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
OPEN
COM
CLOSE
GATE
STATUS
BATTERY
IN USE
POWER
24V
GND
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
GND
RADIO GND
is ON
EXIT
EXIT
CENTER
RADIO SIG.
Turned OFF - Close timer will close the gate. If an in-ground safety or exit loop
ANTI
gets activated during the close cycle, gate will REVERSE to the open position.
TAILGATE
Turned ON - (In-ground loops required) Gate will close after all the in-ground
ON
OFF
loops have been cleared no matter how long the close timer is set for. If an
in-ground safety loop gets activated during the close cycle, gate will REVERSE LED stays ON
to the open position.
when Anti Tailgate
ANTI
TAILGATE
Single pass anti-tailgate
Turned ON - (In-ground loops required) Gate will close after all the in-ground
loops have been cleared no matter how long the close timer is set for. When an
in-ground safety loop gets activated during the close cycle, gate will PAUSE and
NOT reopen. When loop is cleared, gate will continue to close preventing
UNAUTHORIZED entry.
MATRIX 1 Back
OFF
ON
OFF
ON
Mode 0
OFF
Single Pass Anti-Tailgate
ON When turned “ON”; After a vehicle clears the Safety Loop, a closing
gate will PAUSE if a second vehicle attempts to tailgate. The second
vehicle must then back off the safety loop for the gate to continue
closing. A new radio signal will open the gate.
ON
Mode 1
OFF
Gate in Motion Alarms
Mode 0
ON Motion Alarm sounds before gate moves and continues until gate stops
OFF Motion Alarms OFF
Mode 1
ON Beeper Alert sounds in Battery Back-Up Mode while gate is in motion
OFF Beeper Alert OFF
Radio Safety Pause
1
OFF
ON
When turned "ON" a moving gate will pause if a radio input signal is
received. The next radio signal causes the gate to continue in the
original direction.
WWW.Max.US.com
MADE IN USA
SAFETY LOOP
CENTER LOOP
SAFETY LOOP
AUTHORIZED Vehicle
UNAUTHORIZED Vehicle Approaches
VALID open command was given.
When last Safety Loop is cleared, gate will close.
NOTE: If a VALID open command is received at this
point, gate will stop and reopen.
NO VALID open command is given.
Vehicle is attempting to activate safety loop
before the gate’s close cycle is complete,
expecting gate to reopen.
INSIDE
Property
OUTSIDE
Property
2
SAFETY LOOP
CENTER LOOP
SAFETY LOOP
- Gate Pauses -
UNAUTHORIZED Vehicle
NO VALID open command.
Safety Loop gets activated and PAUSES the closing gate.
Gate will NOT reopen. Vehicle MUST back up for loop to
clear, then gate continues to close. NO unauthorized entry.
27
matrix 1
radio receiver
MATRIX 1
Connect a 3-wire or 4-wire radio receiver to Matrix 1.
Choose 12V or 24V, 250 ma max. power.
CLOSE TIMER ON - Each time the remote button is pressed
during the Close Timer countdown (gate is open) causes the
timer to reset and begin again. When close timer countdown
is complete, gate will close.
Choose 12 VDC
OR 24 VDC
(250 mA Max.)
BATTERY
BACK-UP MODE
PRIMARY
GATE
LEAVE
CLOSED
Removable
Terminal
LEAVE
OPEN
MADE in USA
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
ANTI
TAILGATE
EXIT
12VDC
ON
EXIT
CENTER
COM
NC
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
OFF
CENTER
GND
PHOTOCELL
EDGE 1
UL
SAFETY
MAX
MIN
OFF
EDGE 2
ENTRAP
CLOSE TIMER
24VDC
GND
MAG
LOCK
AUTOMATIC OPEN/CLOSE CONTROLS
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
OPEN
POSITION
RECORDER
12VDC
GND
STOP
MAX
GATE SPEED
OBD PORT
BLACK BOX
CLOSE
REVERSE SENSITIVITY
MOTOR OVERLOAD
MIN
24VDC
24VD
UL ALARM 12V
ALARM RET
RESET
GND
MAX
OPEN
COM
CLOSE
GATE
STATUS
NO LIMIT SWITCH /
CLAMP SLIPPING
OPEN
STOP
CLOSE
COM
GATE DISABLE
JO
LE G
FT
X
TIC
MA
I
ANT TE
LGA
TAI
LS
RO
1 TIME
NT
CO
SE
/CLO
EN
TER
OP
CEN
T
EXI
OR
MOT TS
INPU
OFF
COM
NC
NO
per
Tam COM
GND
IN
per
Tam
E
GAT
PER
TAM
SAF
ETY
PHO
ENT
RAP
T
LIMICH
ERYSWIT
BATT K
PAC
ALA
MO
ER
SE
CLO
TIM
RSE
REVE
T
C
x.U
S.c
om
(+)
GND
(-)
(+)
GND
(-)
Y
TER
BAT USE
IN
POW
ER
ire o
4-WRadi
(+)
GND
(-)
ARY
PRIM
GATE
GND
STRIKE
GND
/ RDR
KEYPAD
GND
L
PHOTOCEL
FIRE DEPT
GND
MAX OPEN
GND
ww
Ma
CLO
E
GAT
TUS
STA
GATE
C
24VD
w.
N
OPE
COM
SE
SE
TY
ITIVI
SENS
LOAD
OVER
/
CH
T SWITPING
LIMI P SLIP
NO
CLAM
OR
MOT
LIMITCH
SWI INE
ON-L
OR
MOT INE
SEC
ON-L
GND
RADIO GND
To
ro
id
N
MIN
MAX
12VD
GND
n
OPE
ED
X
MA E SPE
GAT
-7
X BCule
MAery Mod
Batt
BA
Bat
TTE
RY
E
tery
e
tag
Vol F
1/2
lace
Rep ery
OFF Batt
ON/ ery
Batt
T
TES
ery
Batt
ery
Batt r
Erro
IN
Radio Receiver Mounting Position
Existing holes are for Multi-Code radio receiver
or mount using velcro adhesive tape.
Radio safety pause
MATRIX 1 Back
OFF
ON
OFF
ON
O
Mode 0
Mo
gate will PAUSE if a second vehicle attempts to tailgate. The second
vehicle must then back off the safety loop for the gate to continue
closing.
A new radio signal will open the gate.
clos
ON
Mode 1
Turned ON - The radio transmitter (remote control) can PAUSE a MOVING
gate by pressing the remote button. Pressing the remote button again will
cause the gate to CONTINUE in the SAME direction. This process can be
repeated as many times as desired.
Single Pass Anti-Tailgate
ON When turned “ON”; After a vehicle clears the Safety Loop, a closing
OFF
OFF
Gate in Motion Alarms
ON Motion Alarm sounds before gate m
moves and continues until gate stops
Mode 0
larms OFF
OFF Motion Alarms
ON Beeper Alert sounds in Battery
attery Back-Up Mode while gate is in motion
Mode 1
OFF Beeper Alert OFF
OFF
Radio Safety Pause
WWW.Max.US.com
gate in motion alarms
MODE 0 - Turned ON - Alarm will sound BEFORE and DURING gate cycle
to alert surrounding area.
NOTE: A strobe light can be connected to UL ALARM connection that will
flash ON and OFF when the alarm is sounding. See page 32.
MODE 1 - Turned ON - Alarm will beep when using ONLY battery power
DURING gate cycling. This brings to attention that only battery power is
being used and NOT normal AC power.
MADE IN USA
MATRIX 1 Back
ON
Mode 0
OFF
OFF
ON
Mode 0
ON
Single Pass Anti-Tailgate
ON When turned “ON”; After a vehicle clears the Safety Loop, a closing
OFF
gate will PAUSE if a second vehicle attempts to tailgate. The second
vehicle must then back off the safety loop for the gate to continue
closing. A new radio signal will open the gate.
ON
Mode 1
OFF
Gate in Motion Alarms
Mode 1
ON Motion Alarm sounds before gate moves and continues until gate stops
Mode 0
OFF Motion Alarms OFF
ON Beeper Alert sounds in Battery Back-Up Mode while gate is in motion
Mode 1
OFF
OFF Beeper Alert OFF
OFF
Radio Safety Pause
ON
When turned "ON" a moving gate will pause if a radio input signal is
received. The next radio signal causes the gate to continue in the
original direction.
WWW.Max.US.com
MATRIX 1
MADE IN USA
PRIMARY
GATE
BATTERY
BACK-UP MODE
LEAVE
CLOSED
obd port black box
LEAVE
OPEN
MADE in USA
OBD PORT
BLACK BOX
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
EXIT
ON
EXIT
CENTER
GATE
TAMPER
SAFETY
OFF
Tamper NO
COM
GND
Tamper IN
CENTER
CE
PHOTOCELL
UL
SAFETY
MIN
EDGE 1
MAX
OFF
ENTRAP
EDGE 2
CLOSE TIMER
PARTIAL
P
OPEN
O
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
POSITION
RECORDER
12VDC
GND
OBD PORT
OPEN
STOP
MAX
GATE SPEED
MIN
24VDC
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
OPEN
COM
CLOSE
GATE
STATUS
USB Flash Drive
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO GND
GND
RADIO SIG.
On Board Diagnostics (OBD) port will download a simple .txt file to troubleshoot gate operator errors and to view normal transaction logs.
Plug a USB flash drive into port. LED will flash while file is downloading.
When LED stops flashing, remove flash drive and plug it into any computer
with an available USB port and simple text reader software (typical).
The operator’s event history is stored as a simple .txt file. Contained in
the file is a log of the most recent 1000 events. Quickly identify and
diagnose a complex or intermittent problem. The file can even be
e-mailed to the factory for on site diagnosis if necessary. The files will
be stored as an ongoing event history of the transactions that occur at
the gate operator.
ON
g gate will
ill pause if a radio
di input signal is
When turned "ON" a moving
received. The next radio signal causes the gate to continue in the
original direction.
BATTERY
IN USE
POWER
24V
GND
Se
lec
Vo t Inp
ltag
115 e ut
230VAC
ga
tro
P
STO
TIAL
PAR N
OPE
N
ITIO
POSORDER
REC
T
RADIO SIG.
115
Me
CLO
ER
POR
OBDCK BOX
BLA
VA or
C
X
N
MAX
MIN OFF
TY
SAFE
OPEN
STOP
CLOSE
COM
GATE DISABLE
X
TRI
MA ARD
BO
MA
TIO
TOR
MO
CENT
ID
G
PLU
IN
(+)
GND
(-)
RM
AC
Receiver Input
ELL
E1
EDG
E2
EDG
G
PLU
ID OR
ERR
12V
RM
ALA RET
ET
UL ALARM
RES
GND
ON
EXIT
TOC
UL
r In
CLOS
E
LEAV
OPEN
TO
AU
G
MA K
LOC
1.5S
24V
GND
A
ON
D
M
4
3
LE
Se ER
ns D
itiv
ity
5
15 16
14
12
13
D
ER
O M
ve ot
rL or
oa
d
CK
GLO
MA AY 2Sec
DEL ec
OFF
N
OPEHT
RIG
we
Po
1
USA
E in
N
OPE
LEFT
R
TO
MO
MAD
Y
TER DE
BAT P MO
K-U E
BAC LEAVED OPEN
IN
28
POWER
24V
GND
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
or M
Co C
-2
nt 0
ro 0
W
lle
ER
r
ot
tra
p
SEC
GATE
PO
M
MOTOR
ON-LINE
PRIMARY
GATE
BATTERY
IN USE
UL
En
LIMIT
SWITCH
ON-LINE
Ce
ll
Ed
ge
IX
oto
Ph
1
2
Lim
it
SW
Ed
ge
MA
TR
ire o
3-WRadi
RI JO
G G
H
T
LT
g
Jo g RT
Jo GND 1
ge 2
Ed ge o
Ed ot l
Ph el
C
LINE
ON-
RY
MA
PRI E
GAT
IX
TR
MA
RS-485 (+) RS-485 (-) GND PWR 24V -
CLOSE TIMER OFF - Sequence when
pressing remote button:
Press One Time - gate OPENS . . .
Press Again - gate STOPS . . .
Press Again - gate CLOSES . . .
Press Again - gate STOPS . . .
Sequence repeats when button is
pressed again.
RADIO GND
GND
NOTE: See page 46 for
more information about
this unique feature.
matrix 1
MAG
LOCK
MATRIX 1
Pos
COM
NC
LEAVE
OPEN
MADE in USA
Tamper NO
COM
PRIMARY
GATE
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
Neg
EXIT
-
ON
EXIT
CENTER
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
OFF
CENTER
PHOTOCELL
PHOT
EDGE 1
UL
SAFETY
MIN
MAX
OFF
EDGE 2
ENTRAP
CLOSE TIMER
Maglock
Dual Gate Operators: Primary gate
opens FIRST. Install maglock
accordingly to account for this.
+
-
OPEN
POSITION
RECORDER
12VDC
GND
STOP
MAX
GATE SPEED
OBD PORT
BLACK BOX
CLOSE
REVERSE SENSITIVITY
MOTOR OVERLOAD
MIN
24VDC
UL ALARM 12V
ALARM RET
RESET
GND
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
OPEN
COM
CLOSE
GATE
STATUS
GND
Maglock
Power
Matrix 1 will accept third party loop detectors in the 3 ports. Each loop detector has a
corresponding in-ground loop that must be connected for the loop system to operate
(see below). Power down Matrix 1 BEFORE connecting loop detectors. Refer to your
chosen loop detector’s instruction sheet for specific information about loop detector.
MATRIX 1
BATTERY
BACK-UP MODE
MOTOR
ON-LINE
PRIMARY
GATE
SEC
GATE
BATTERY
IN USE
POWER
PRIMARY
GATE
LEAVE
CLOSED
LEAVE
OPEN
MADE in USA
LIMIT
SWITCH
ON-LINE
24V
GND
Neg
ID
PLUG
OPEN
STOP
CLOSE
COM
GATE DISABLE
Pos
ID PLUG
ERROR
MOTOR MOTION
(+)
GND
(-)
Tamper IN
PARTIAL
OPEN
(+)
GND
(-)
GND
Loop Detectors
BATTERY
BACK-UP MODE
LEAVE
CLOSED
+
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
2Sec
FIRE DEPT
GND
MAX OPEN
GND
Maglock MUST be connected as shown.
MAGLOCK DELAY: You MUST select a time
delay when using a maglock.
Maglock power disengages 1.5 sec or
2 sec before gate starts opening.
MAGLOCK LED (Monitors Maglock):
ON - Locked OFF - Unlocked
Flashing - Problem with Maglock Power.
RADIO GND
OFF 1.5Sec
RADIO SIG.
MAGLOCK
DELAY
maglock
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC
UTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
EXIT
ON
EXIT
CENTER
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
OFF
CENTER
PHOTOCELL
Connect desired loop detector
to appropriate loop port
ON
1
OPTIONS
4
4
5
6
7
8
ON
00
A18
LM
NS
SE
MET
Tel:
DEF
480.
96
6
I
5 = LECT 8.
64
Op O
= In tim MET 07
= Decreaum Se ER
crease Se ns.
se ns.
D
Se
PO IND
ns.
ONWER ICAT
OR
OF = No
S
DEF= No rmal
ONTECT Pow Pow
er er
OF = De
2 HzF= No tect
Lo Flas Dete
op h=
1 Fl Fa Delact
2 Fl ash ult y Tim
3 Flashes== Open ing
ashe Sh Lo
s=25 orte op
Both
% chd Loop
Cu LED’ of In an
PW rrent s Flasducta ge
R
Lo hi nc
PrevLED Fl op Fang= e
ious ashi ult
Loop ng=
Faul
t
Loop Detector
(Plug-In)
MAX Part number:
MAX D-TEK
LE
ER
TO
EC
FL
DE
NS
SE
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
BATTERY
IN USE
POWER
7
8
ON
1
2
3
SW
4
ON 1 SW
5
6
ON ON 2
7
OF OF = Freque
8
OFF ONF = Low ncy
F
SW OF = Mediu
F Med m-L
ON 3
=
iu
OF = Fa High m-How
F
igh
SW = Fail Se
ON 4 SW il Sacure
ON ON 5 fe
OF OF = Outp
ut
OFF ONF = Pulse B
F
B sa on
SW OF = Pu
En
F = ls me as
try
ON 6
Loope on A
OF = 2
FaulExit
SWF = NoSeco
t
ON 7
De nd De
OF = No lay lay
SWF = In rmal
fin Pr
ON 8
ite es
Presence
OF = Se
F = ns
ence
No itivi
Se ty Bo
nsiti os
vity t
Bo
ost
800
A1
LMS
SE
N
ER
MET
EC
TO
Plug-In Loop Detector
FL
DE
NS
SE
R
WE
PO
CT
TE DI
DE
E
T
SE
RE
WER
T
EC
ET
PO
D
I
ED
T
SE
RE
External Loop Detectors
Third party external loop detectors can be used if
desired with the MAX External Loop Detector Cable
Adapter. (1) One is included with the operator but
more can be purchased if needed.
Com, Gnd (Black)
r
we
Po inal
m
r
Te
Wire to
al back of
n
r
e
Extoop r detector
L cto
te
De
Power 15 VDC (Red)
MAX External Loop
Detector Cable Adapter Power Terminal
Removable Terminal
MATRIX 1
BATTERY
BACK-UP MODE
PRIMARY
GATE
LEAVE
CLOSED
LEAVE
OPEN
MADE in USA
EXIT
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TTAILGATE
EXIT
ON
EXIT
CENTER
GATE
TAMPER
SAFETY
OFF
Tamper NO
COM
GND
Tamper IN
CENTER
CENTER
PHOTOCELL
UL
SAFETY
MIN
EDGE 1
MAX
OFF
ENTRAP
EDGE 2
CLOSE TIMER
PARTIAL
OPEN
SAFETY
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
POSITION
RECORDER
12VDC
Safety loops need
to be wired in series.
GND
OBD PORT
BLACK BOX
24VDC
OPEN
STOP
MAX
GATE SPEED
MIN
CLOSE
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
UL ALARM 12V
ALARM RET
RESET
GND
OPEN
COM
CLOSE
GATE
STATUS
GND
LIMIT
SWITCH
ON-LINE
MOTOR
ON-LINE
PRIMARY
GATE
SEC
GATE
BATTERY
IN USE
POWER
Lead
Wires
Outside Property
SAFETY LOOP
CENTER LOOP
SAFETY LOOP
EXIT LOOP
Inside Property
In-ground loop connection
Connect each in-ground loop wires to the appropriate input. Lead wires
should be twisted together 6 twists per foot
minimum.
See page 14 for in-ground loop installation.
Safety loop wires must be wired in series.
Each LED will light when the corresponding
loop detector get activated by a vehicle
passing over its in-ground loop.
LEDs will flash when
there is an error with the
corresponding loop
detector.
NOTE: Reno H2 detector
always blinks steadily
during normal operation.
Loop Detect
Output (White)
24V
GND
2
-LP
ED
FR
5
OPEN
STOP
CLOSE
COM
GATE DISABLE
1
3
SW
4
ON 1 SW
5
6
ON ON 2
7
OF OF = Freque
8
OFF ONF = Low ncy
F
SW OF = Mediu
F Med m-L
ON 3
=
iu
OF = Fa High m-How
F
igh
SW = Fail Se
ON 4 SW il Sacure
ON ON 5 fe
OF OF = Outp
ut
OFF ONF = Pulse B
F
B sa on
SW OF = Pu
En
F = ls me as
try
ON 6
Lo e on A
OF = 2
op Ex
Fa it
SWF = NoSeco
ult
ON 7
De nd De
OF = No lay lay
SWF = In rmal
fin Pr
ON 8
ite es
Presence
OF = Se
F
en
= Nonsiti
ce
Se vity Bo
nsiti os
vity t
Bo
ost
EQ
4
(+)
GND
(-)
I
3
T
CO
(+)
GND
(-)
7
6
5
4
3
Loop Detector
Low Current
Draw
(Plug-In)
96
ON
2
UN
EMX
LIMIT
SWITCH
ON-LINE
ETER
1
3
480.
FL
5 = EC
8.64
Op TO
= In tim MET 07
= Decreaum Se ER
crease Se ns.
LE
se ns
D
PO INDI Sens.
ONWER CATO .
OF = No
RS
DEF= No rmal
ONTECT PowePowe
r r
OF = De
2 HzF= No tect
LoopFlash Dete
1 Fl Fa =Delact
2 Flaash ult y Tim
3 Fl shes= Open ing
ashe = Sh Lo
s=25 orted op
Both
% ch Loop
Cu LED’ of In an
PW rrent s Flasducta ge
R
Lo hi nc
PrevLED Fl op Fang= e
ious ashi ult
Loop ng=
Faul
t
AM
ET
S
RE
OPEN
COM
CLOSE
GATE
STATUS
CT
WER
PO
I
ED
2
DE
TE
(+)
GND
(-)
TR
UL
WER
T
EC
PO
1
ED
Tel:
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
NS
SE
DET
ON
EDI
DE
FL
EPT
FIRE DEPT
GND
MAX OPEN
GND
ER
MET
TO
EC
DE
CLOSE
REVERSE SENSITIVITY
MIN
MAX
M
8
FAIL
STOP
MAX
GATE SPEED
SPE
SAFETY
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
EC
T
2
2
EC
ON 10
SEC
OFF
ON
5S
EC O
ON 10 N
SEC
OFF
ON
O
OFF N
FA OFF
IL
SA
M OFF FE
ED
OFF
HIG
ON
OFFH
SEN
O
0 SIT FF
IV
3
LO ITY
7 NO W
R
HIG M
H
1
LH
5S
ON
DE
WER
DET
CENTER
UL ALARM 12V
ALARM RET
RESET
GND
OPTIONS
MO
PO
EXIT
RADIO
DIO GND
NA&O
OPEN
N
SE
RADIO SIG.
RE
E
EX
T=
SW
0S
SW 8
EC
OFF 2
DLY7
SEC
OFF
SW =
OFF
0S
SW 6
EC ON
BO 5 OFF 2 S
O
EC
OFF
OFF
SWST
4
M
O
OD
ON N
SW E FA
O
FR 3
IL N
SEC
EQ
SW =
LO ON URE
SW 2
W
1 ON NO
RM
ON
O
N
VEH
OFF
IC
LE
8- DET
30
EC
VD TO
C
R
800
A1
LMS
2
OPTIONS
Loop Detector
(Plug-In)
LED always
blinks steadily
during
operation
Loop Detector
(Plug-In)
1
3
SW
4
ON 1 SW
5
6
ON ON 2
7
OF OF = Freque
8
OFF ONF = Low ncy
F
SW OF = Mediu
F = Med m-L
ON 3
iu
OF = Fa High m-How
F
igh
SW = Fail Se
ON 4 SW il Sacure
fe
5
ON ON
OF OF = Outp
ut
OFF ONF = Pulse B
F
B
SW OF = Pusamon En
F = ls e as try
ON 6
Lo e on A
OF = 2
op Ex
Faul it
SWF = NoSeco
t
ON 7
De nd De
OF = No lay lay
SWF = In rmal
fin Pr
ON 8
ite es
Presence
OF = Se
F = ns
ence
No itivi
Se ty Bo
nsiti os
vity t
Bo
ost
EDGE 2
ID PLUG
ERROR
ID
PLUG
OPEN/CLOSE CONTROLS
FIRE DEPT
GND
MAX OPEN
GND
Reno
8
RADIO GND
De se Sens
crea Se .
se ns
D
PO INDI Sens.
ONWER CATO .
OF = No
RS
DEF= No rmal
ONTECT PowePowe
r r
OF = De
F=
2 Hz No tect
LoopFlash Dete
1 Fl Fa =Delact
2 Flaash ult y Tim
3 Fl shes= Open ing
ashe = Sh Lo
s=25 orted op
Both
% ch Loop
Cu LED’ of In an
PW rrent s Flasducta ge
R
Lo hi nc
PrevLED Fl op Fang= e
ious ashi ult
Loop ng=
Faul
t
LE
EDI
7
ON
1 2 3 4
DE
0.
FL 968.
5 = EC
64
Op TO
= In tim MET 07
= creaum ER
ON DIP
Plug-In Loop Detectors
6
I
Tel:
48
EDGE 1
ENTRAP
MOTOR MOTION
RADIO SIG.
ED
5
MAX
OFF
24V
GND
3
MIN
CLOSE TIMER
OPEN
STOP
CLOSE
COM
GATE DISABLE
2
UL
SAFETY
29
matrix 1
MATRIX 1
MAX
MEGATRON
1400
2Sec
MAG
LOCK
MAX
MEGATRON
2200
EXIT
EX
CENTER
COM
NC
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
PHOTOCELL
EDGE 1
MIN
OFF
EDGE 2
ENTRAP
ID PLUG
ER
ERROR
PARTIAL
OPEN
ID
PLUG
GND
MAX
GATE SPEED
OBD PORT
BLACK BOX
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
MOTOR OVERLOAD
MIN
24VDC
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
OPEN
COM
CLOSE
GATE
STATUS
GND
SEC
GATE
POWER
24V
GND
MOTOR
ON-LINE
PRIMARY
GATE
BATTERY
IN USE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
Warning
Light
STOP
OPEN
POSITION
RECORDER
12VDC
12
RADIO GND
ID
PLUG
MAX
MEGATRON
FAST
Power
OFF 1.5Sec
CLOSE TIMER
FAST
Siren
MAGLOCK
DELAY
OPEN
RIGHT
SAFETY
2200
Security
Camera
Power
MATRIX 1
BATTERY
BACK-UP MODE
PRIMARY
GATE
LEAVE
CLOSED
OPEN
LEFT
OPEN
1 TIME
LEAVE
OPEN
MADE in USA
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
EXIT
ON
EXIT
CENTER
Tamper NO
Tamp
COM
GND
Tamper IN
GA
GATE
TAMPER
SAFETY
OFF
CENTER
PHOTOCELL
PHOTOC
MIN
MAX
OFF
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
OPEN
POSITION
RECORDER
12VDC
GND
STOP
MAX
GATE SPEED
OBD PORT
BLACK BOX
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
MOTOR OVERLOAD
MIN
24VDC
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
OPEN
COM
CLOSE
GATE
STATUS
GND
TAMPER IN/GND Input: Connect a sensor device to input. When
Tamper In/GND gets triggered, device that is wired to Tamper
relay (NO/Com) will activate.
Motion
Sensor
POWER
24V
GND
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
BATTERY
IN USE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
TAMPER NO/Com Relay: Connect a warning light, siren, camera
or an existing alarm system to relay.
EDGE 2
ENTRAP
CLOSE TIMER
FIRE DEPT
GND
MAX OPEN
GND
GATE
TAMPER
Tamper NO
COM
GND
Tamper IN
EDGE 1
UL
SAFETY
RADIO GND
Existing
The GATE TAMPER can be used for various
Building
Alarm
functions such as turning a warning light, siren or System
camera on when the gate is tampered with
(Vandalized Gate). The gate operator defines a
“Vandalized Gate” as UNAUTHORIZED movement
of the gate. This can occur if the red release
handle clamp is lifted and gate is manually moved
from the closed position or the gate is forced
open from the closed position without authorization.
ANTI
TAILGATE
RADIO SIG.
Gate Tamper
PRIMARY
GATE
OPEN
LEFT
OPEN
1 TIME
AUTOMATIC OPEN/CLOSE CONTROLS
AU
1400
ID PLUG ERROR LED: Will light when ID PLUG is missing.
LEAVE
OPEN
MADE in USA
(+)
GND
(-)
AN ID Plug comes standard on Matrix 1. It identifies the model of
gate operator and MUST be plugged in or the Matrix 1 WILL NOT
function.
Purple is for the MAX Megatron 1400.
Green is for the MAX Megatron 2200.
Orange is for the MAX Megatron FAST.
BATTERY
BACK-UP MODE
LEAVE
CLOSED
ID PLUG
ERROR
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
id plug
NOTE: See page 45 for
more information about
this unique feature.
UL entrapment LEDs
UL ENTRAPMENT LEDs will indicate when a OPENING DIRECTION
Photocell and/or Sensing Edge(s) have been activated. If alarm gets
triggered, press STOP button on Matrix 1 to turn alarm off.
MATRIX 1
LEAVE
CLOSED
PHOTOCELL
ANTI
TAILGATE
UL
OPEN
LEFT
OPEN
1 TIME
ON
EDGE 1
EXIT
CENTER
2Sec
MAG
LOCK
COM
NC
Tamper NO
COM
GND
Tamper IN
Tam
GATE
TAMPER
SAFETY
OFF
PHOTOCELL
EDGE 1
UL
SAFETY
EDGE 2
MIN
MAX
OFF
EDGE 2
ENTRAP
CLOSE TIMER
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
CLOSE
OPEN
POSITION
GND
ND
NOTE: UL safety approved devices are wired to the MC-200 motor
controllers ONLY. DO NOT wire them to the Matrix 1.
STOP
MAX
SPEED
GATE SP
ED
12VDC
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SEN
SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWIT
SWITCH /
CLAMP
CLAM SLIPPING
24VDC
OPEN
COM
CLOSE
GATE
STATUS
SEC
GATE
POWER
24V
GND
MOTOR
ON-LINE
PRIMARY
GATE
BATTERY
IN USE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
T
FIRE DEPT
GND
MAX OPEN
GND
REVERSE SENSITIVITY
RADIO GND
O SIG.
RADIO
GND
(+)
GND
(-)
STOP
OFF 1.5Sec
CENTER
ENTRAP
OPEN
MAGLOCK
DELAY
OPEN
RIGHT
AUTOMATIC OPEN/
OPEN/CLOSE CONTROLS
EXIT
MOTOR MOTION
PRIMARY
GATE
BATTERY
BACK-UP MODE
LEAVE
OPEN
MADE in USA
REVERSE SENSITIVITY LED: Will light when the gate encounters an
obstruction triggering the ERD sensor.
emergency vehicle/max open inputs
MATRIX 1
PRIMARY
GATE
BATTERY
BACK-UP MODE
LEAVE
CLOSED
LEAVE
OPEN
MADE in USA
FIRE DEPT
GND
MAX OPEN
GND
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
ANTI
TAILGATE
EXIT
ON
EXIT
CENTER
GATE
TAMPER
SAFETY
OFF
PHOTOCELL
UL
SAFETY
MIN
EDGE 1
MAX
OFF
ENTRAP
EDGE 2
CLOSE TIMER
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
30
Tamper NO
COM
GND
Tamper IN
CENTER
PARTIAL
OPEN
12VDC
GND
POSITION
RECORDER
OBD PORT
BLACK BOX
24VDC
DC
OPEN
STOP
MAX
GATE SPEED
MIN
CLOSE
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
UL ALARM 12V
ALARM RET
RESET
GND
OPEN
COM
CLOSE
GATE
STATUS
Knox
Box
Key
Switch
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
GND
FIRE DEPT
GND
MAX OPEN
GND
MAX OPEN Input: Can be connected to a key switch and used as an
ADDITIONAL input from the FIRE DEPT input. The input will override
the GATE DISABLE input and allow SECURITY personnel FULL 24/7
access. Gate fully opens.
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
IN USE
POWER
24V
GND
FIRE DEPT lnput: Should be connected to a knox box device to allow
the proper authorities to gain emergency access when necessary. The
input will override the GATE DISABLE input and allow EMERGENCY
personnel FULL 24/7 access. Gate fully opens.
matrix 1
GND
GATE DISABLE
gate disable
An ON/OFF switch or 7-Day timer devices can be connected to the GATE DISABLE
input. When these devices are turned ON, they will DISABLE normal opening
devices such as keypad, exit loop etc. The FIRE DEPT/ MAX OPEN and RADIO
inputs will remain enabled when GATE DISABLE has been turned ON. This is
useful when the gated area needs to be secured from ALL but emergency or
authorized vehicle entry. Some examples are: Residential home vacation period or
during closed hours of a business when no one can monitor the property.
MATRIX 1
PRIMARY
GATE
BATTERY
BACK-UP MODE
LEAVE
CLOSED
OPEN
LEFT
OPEN
1 TIME
LEAVE
OPEN
MADE in USA
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
MAG
LOCK
2Sec
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
EXIT
ON
EXIT
CENTER
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
OFF
CENTER
PHOTOCELL
EDGE 1
UL
SAFETY
MIN
IN
MAX
OFF
EDGE 2
ENTRAP
CLOSE TIMER
ER
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
OPEN
PEN
POSITION
RECORDER
12VDC
GND
STOP
MAX
GATE SPEED
OBD PORT
MOTOR
OTOR OVERLOAD
MIN
24VDC
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
SENSITIV
NO LIMIT SWITCH
WITCH /
CLAMP SLIPPING
PING
MAX
OPEN
COM
CLOSE
GATE
ST
STATUS
BATTERY
IN USE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
POWER
24V
GND
(+)
STRIKE
GND
DR
KEYPAD / RDR
GND
PHOTOCELL
ELL
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
ON
When GATE DISABLE is turned ON: The operator will beep for 3 minutes
BEFORE arming itself. This allows time to turn ON GATE DISABLE and
leave the property before it is armed.
RADIO GND
GND
F
OF
7-Day
Timer
ON/OFF
Switch
Enabled inputs when
GATE DISABLE is turned ON.
NOTE: See page 46 for
more information about
this unique feature.
When FIRE DEPT/MAX OPEN gets activated: Gate opens and GATE TAMPER
relay will activate immediately.
When RADIO Input gets activated: Gate opens and GATE TAMPER relay will activate after 3 min. This allows time to turn OFF
GATE DISABLE or disarm an existing building alarm system if connected.
IMPORTANT: It is NOT recommended activating the GATE DISABLE device while persons are present inside the property.
partial open
A gate can set to partially open by recording the PARTIAL OPEN gate cycle. LED will stay lit
when PARTIAL OPEN is ON.
MATRIX 1
PRIMARY
GATE
BATTERY
BACK-UP MODE
LEAVE
CLOSED
LEAVE
OPEN
MADE in USA
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
EXIT
IMPORTANT: Limit switches MUST be learned BEFORE Partial Open can be recorded.
ON
EXIT
CENTER
GATE
TAMPER
SAFETY
OFF
Tamper NO
COM
GND
Tamper IN
CENTER
PHOTOCELL
UL
SAFETY
MIN
EDGE 1
MAX
OFF
ENTRAP
EDGE 2
CLOSE TIMER
PARTIAL
OPEN
ID
PLUG
MOTOR MOTION
POSITION
RECORDER
12VDC
GND
OPEN
STOP
MAX
GATE SPEED
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
SLIP
OPEN
COM
CLOSE
GATE
STATUS
SEC
GATE
BATTERY
IN USE
POWER
24V
GND
MOTOR
ON-LINE
PRIMARY
GATE
OPEN
STOP
CLOSE
COM
GATE DISABLE
CLOSE
(+)
GND
(-)
STOP
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
OPEN
ND
RADIO GND
POSITION
RECORDER
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
GND
RADIO SIG.
1. With gate in CLOSED position, press and release PARTIAL OPEN
button to START recording. Blue LED starts flashing.
OBD PORT
BLACK BOX
24VDC
GND
MAX OPEN
GND
To RECORD PARTIAL OPEN:
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
2. Press 3-button station OPEN button to start gate’s open cycle.
3. Press 3-button station STOP button when gate is in desired partial open position (Beyond center loop).
4. Press PARTIAL OPEN button AGAIN to STOP recording. Blue LED stops flashing,
open position has been recorded. LED remains ON.
To ERASE PARTIAL OPEN recording:
Press and HOLD PARTIAL OPEN button for 5 sec. LED turns OFF.
CENTER LOOP
NOTE: The FIRE DEPT and/or MAX
OPEN connected devices will always
FULLY open gates even when the
partial open is being used.
CAUTION: Gates partial OPEN
position MUST be outside the
Center Loop when in-ground
loops have been installed.
31
matrix 1
UL alarm / Alarm shut-off
MATRIX 1
A UL ALARM (strobe light) can be connected. It will turn
ON when the GATE IN MOTION - Mode 0 and/or Mode 1
are turned ON (see page 28).
BATTERY
BACK-UP MODE
PRIMARY
GATE
LEAVE
CLOSED
UL ALARM 12V
ALARM RET
RESET
GND
OPEN
LEFT
OPEN
1 TIME
LEAVE
OPEN
MADE in USA
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
EXIT
ON
EXIT
CENTER
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
OFF
PHOTOCELL
EDGE 1
UL
Strobe
Light
Press STOP BUTTON to Shut-OFF activated strobe light.
MIN
OFF
EDGE 2
ENTRAP
EN
CLOSE TIMER
ID PLUG
ERROR
MOTOR MOTION
MOTOR MOTION
OPEN
POSITION
STOP
MAX
GATE SPEED
12VDC
GND
MOTOR OVERLOAD
MIN
MI
24VDC
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIV
SENSITIVITY
VITY
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
OPEN
COM
CLOSE
GATE
STATUS
POWER
24V
GND
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
BATTERY
IN USE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
CLOSE
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
STOP
FIRE DEPT
GND
MAX OPEN
GND
OPEN
RADIO SIG.
Press STOP BUTTON to Shut-OFF an activated alarm.
RADIO GND
GND
STROBE LIGHT NOTE: 12VDC - 250 mA max.
MATRIX 1
gate status monitoring
BATTERY
BACK-UP MODE
PRIMARY
GATE
LEAVE
CLOSED
GATE
STATUS
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
EXIT
ON
EXIT
CENTER
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
OFF
CENTER
PHOTOCELL
EDGE 1
UL
SAFETY
MAX
MIN
OFF
EDGE 2
ENTRAP
CLOSE TIMER
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
GND
N
PE
O
TE
GA
STOP
MAX
GATE SPEED
OBD PORT
BLACK BOX
UL ALARM 12V
ALAR
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
Y
MOTOR OVERLOAD
OVERL
MIN
24VDC
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
OPEN
COM
CLOSE
CL
GATE
STATUS
POWER
24V
GND
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
BATTERY
IN USE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
FIRE DEPT
GND
MAX OPEN
GND
ED
OS
CL
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
GND
RADIO GND
TE
GA
OPEN
POSITION
RECORDER
12VDC
Remote Gate
Monitoring Device
in Remote Location
RADIO SIG.
GATE STATUS LEDs will turn ON when gate is in the OPEN or
CLOSED position.
Connect a gate monitoring device to GATE STATUS relays to show
if gate is in the OPEN or CLOSED position.
OPEN/COM Relay: Activates when gate gets to the OPEN position.
CLOSE/COM Relay: Activates when gate gets to the CLOSED
position.
OPEN
COM
CLOSE
OPEN
LEFT
OPEN
1 TIME
LEAVE
OPEN
MADE in USA
open / stop / close Connection
MATRIX 1
PRIMARY
GATE
BATTERY
BACK-UP MODE
LEAVE
CLOSED
The OPEN/STOP/CLOSE inputs will allow a standard 4-wire 3-Button
Station and a External Alarm RESET Button to be connected.
Corresponding LEDs will light when each button is activated.
OPEN
STOP
CLOSE
COM
GATE DISABLE
OPEN
LEFT
OPEN
1 TIME
LEAVE
OPEN
MADE in USA
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
EXIT
ON
EXIT
CENTER
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
OFF
CENTER
PHOTOCELL
EDGE 1
UL
SAFETY
MAX
MIN
OFF
EDGE 2
ENTRAP
CLOSE TIMER
TIM
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
OPEN
OPEN
POSITION
ON
RECORDER
12VDC
GND
STOP
MAX
GATE SPEED
OBD PORT
BLACK BOX
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE
REVERS SENSITIVITY
MOTOR OVERLOAD
OVERL
MIN
24VDC
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
OPEN
COM
CLOSE
GATE
STATUS
to
Com
MOTOR
ON-LINE
PRIMARY
GATE
SEC
GATE
POWER
24V
GND
ET
S
RE
BATTERY
IN USE
OPEN
STOP
CLOSE
COM
GATE DISABLE
PR
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
S
ES
(+
(+)
GND
G
(-)
STOP
Com
FIREE DEPT
ND
GND
MAX OPEN
GND
STOP
CLOSE
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
PHOT
GND
GND
O GND
RADIO
An external Alarm Reset button needs to be installed in
a secure place and connected as shown to quickly
SHUT-OFF a sounding alarm. Otherwise alarm can only
be shut-off by the STOP BUTTON on the Matrix 1 (see
Alarm Shut-Off above).
PARTIAL
OPEN
RADIO SIG.
External Alarm Reset Button
3-Button
Station
External Alarm
Reset Button
closing photocell connection
MATRIX 1
CLOSING
GATE
DIRECTION
OUTSIDE Property
32
12V or 24V
Photocells
PRIMARY
GATE
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
ANTI
TAILGATE
EXIT
12VDC
ON
EXIT
CENTER
COM
NC
OFF
Tamper NO
COM
GND
Tamper IN
CENTER
PHOTOCELL
UL
EDGE 1
MAX
MIN
OFF
ENTRAP
EDGE 2
CLOSE TIMER
24VDC
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
POSITION
RECORDER
12VDC
GND
OBD PORT
BLACK BOX
24VDC
24VD
OPEN
STOP
MAX
GATE SPEED
MIN
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
OPEN
COM
CLOSE
GATE
STATUS
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO GND
GND
RADIO SIG.
Power
GND
N.O.
GND
MAG
LOCK
GATE
TAMPER
SAFETY
SAFETY
GND
2Sec
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
IN USE
POWER
PHOTOCELL
GND
INSIDE Property
LEAVE
OPEN
MADE in USA
GND
NOTE: This input is typically used when an existing normally open
photocell needs to be retro-fitted to this operator when this
operator is replacing an obsolete operator.
BATTERY
BACK-UP MODE
LEAVE
CLOSED
Choose 12 VDC OR 24 VDC
(250 mA Max.)
24V
GND
The Normally OPEN PHOTOCELL input will allow a CLOSING DIRECTION
Normally OPEN PHOTOCELL to be connected. 12V or 24V power can be
supplied for the photocells.
IMPORTANT: This input is NOT UL 325 entrapment protection.
Additional CLOSING Cycle
Photocells can be connected.
matrix 1
gate operators communication leds
MATRIX 1
BATTERY
BACK-UP MODE
PRIMARY
GATE
LEAVE
CLOSED
PRIMARY operator’s MC-200 has been wired to the
PRIMARY GATE (Factory Wired).
LIMIT
SWITCH
ON-LINE
OPEN
LEFT
OPEN
1 TIME
LEAVE
OPEN
MADE in USA
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
EXIT
ON
EXIT
CENTER
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
OFF
CENTER
PHOTOCELL
MOTOR
ON-LINE
OFF
O
EDGE 2
ENTRAP
PARTIAL
OPEN
PRIMARY
GATE
SEC
GATE
ID PLUG
ERROR
MOTOR MOTION
PLUG
OPEN
O
POSITION
RECORDER
12VDC
GND
STOP
MAX
GATE SPEED
OBD PORT
ACK BOX
BLACK
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
MOTOR OVERLOAD
MIN
24VDC
NO LIMIT
LIM SWITCH /
CLAMP SLIPPING
S
MAX
OPEN
STOP
CLOSE
COM
GATE DISABLE
POWER
24V
GND
(+)
GND
(-)
KEYPAD / RDR
GND
PHOTOCELL
GND
SEC
GATE
(+)
GND
(-)
MAX OPEN
FIRE DEPT
D
RADIO GND
RADIO SI
SIG.
MOTOR
ON-LINE
PRIMARY
GATE
BATTERY
IN USE
MOTOR
Power In
MOTOR
INPUTS
BATTERY LIMIT ALARM
SWITCH
PACK
MATRIX
BOARD
GND -
not used -
not used -
MOTOR
RS-485
LIMIT
SWITCH
ON-LINE
Secondary
MAX MC-200
PWR 12V -
RS-485 (+) RS-485 (-) GND PWR 24V -
Power In
MOTOR
INPUTS
BATTERY LIMIT ALARM
SWITCH
PACK
MATRIX
BOARD
GND -
not used -
not used -
Factory Wired
RS-485
24V power for matrix 1
MATRIX 1
POWER
PRIMARY
GATE
BATTERY
BACK-UP MODE
LEAVE
CLOSED
OPEN
LEFT
OPEN
1 TIME
LEAVE
OPEN
MADE in USA
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
24V
GND
24VDC POWER from PRIMARY operator ONLY.
POWER LED: Will light when 24V low voltage power is
connected.
ANTI
TAILGATE
EXIT
ON
EXIT
CENTER
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
OFF
CENTER
PHOTOCELL
EDGE 1
UL
SAFETY
EDGE 2
ENTRAP
ID PLUG
ERROR
MOTOR MOTION
MOTO
ID
PLUG
Primary
MAX MC-200
OPEN
STOP
MAX
GATE SPEED
12VDC
GND
24VDC
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT
IT SWITCH /
CLAMP SLIPPING
LIPPING
MAX
OPEN
COM
CLOSE
GATE
STATUS
BATTERY
BATTER
IN USE
GAT
GATE DISABLE
POWER
24V
GND
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELLL
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO GND
RADIO SIG.
GND
MOTOR
Power In
MOTOR
INPUTS
BATTERY LIMIT ALARM
SWITCH
PACK
MATRIX
BOARD
GND -
not used -
not used -
PWR 12V -
RS-485 (+) RS-485 (-) GND PWR 24V -
NOTE: DO NOT power any external devices using this
connection. This power is reserved for Matrix 1 ONLY.
OPEN
COM
CLOSE
GATE
STATUS
GND
Primary
MAX MC-200
PWR 12V -
RS-485 (+) RS-485 (-) GND PWR 24V -
MOTOR ON-LINE LEDs: will light for
each gate operator’s MC-200 Motor
Controller that the Matrix 1 is
successfully communicating with.
MAX
MIN
CLOSE TIMER
TIME
(+)
GND
(-)
LIMIT SWITCH ON-LINE LEDs: will light for each gate
operator’s limit switch that the Matrix 1 is successfully
communicating with.
EDGE 1
UL
SAFETY
(+)
GND
(-)
SECONDARY operator’s MC-200 gets connected to the
SEC GATE (+, GND, -). See page 22.
24V
Factory Wired
MATRIX 1
PRIMARY
GATE
BATTERY
BACK-UP MODE
LEAVE
CLOSED
LEAVE
OPEN
MADE in USA
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
EXIT
BATTERY
IN USE
ON
EXIT
CENTER
Tamper NO
COM
GND
Tamper IN
GATE
TAMPER
SAFETY
OFF
CENTER
C
PHOTOCELL
EDGE 1
UL
SAFETY
MIN
MAX
OFF
EDGE 2
ENTRAP
CLOSE TIMER
POWER
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
OPEN
POSITION
RECORDER
12VDC
GND
STOP
MAX
GATE SPEED
OBD PORT
BLACK BOX
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
MOTOR
TOR OVERLOAD
MIN
24VDC
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
OPEN
COM
C
CLOSE
GATE
STATUS
POWER
24V
GND
SEC
GATE
(+)
GND
(-)
MOTOR
OTOR
ON-LINE
PRIMARY
GATE
BATTERY
IN USE
OPEN
STOP
CLOSE
COM
GATE DISAB
DISABLE
LIM
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
FIRE DEPT
GND
MAX OPEN
GND
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
GND
RADIO GND
BATTERY IN USE LED will light when operator is using ONLY battery
back-up power. The GATE IN MOTION Alarm can be set up to sound alarm
when operator is using ONLY battery power DURING gate cycling. This
brings to attention that only battery power is being used and NOT normal
AC power. See page 28.
LED Flashing NOTE: BATTERY IN USE and POWER LEDs flash together
when the battery is not plugged into the BATTERY IN port of the MAX BC-7
Battery Module. Make sure battery plug is correctly installed and there is no
damaged or loose wires.
RADIO SIG.
battery in use led
motor motion leds
REVERSE SENSITIVITY LED: Will light when the gate encounters an obstruction triggering
the ERD sensor.
MATRIX 1
PRIMARY
GATE
BATTERY
BACK-UP MODE
LEAVE
CLOSED
OPEN
LEFT
OPEN
1 TIME
LEAVE
OPEN
MADE in USA
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
MAG
LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
EXIT
ON
REVERSE SENSITIVITY
EXIT
CENTER
GATE
TAMPER
SAFETY
OFF
CENTER
CEN
PHOTOCELL
MOTOR OVERLOAD
UL
SAFETY
MIN
PARTIAL
OPEN
EDGE 2
ID PLUG
ERROR
MOTOR MOTION
MOT
ID
PLUG
POSITION
RECORDER
12VDC
GND
OBD PORT
BLACK BOX
24VDC
OPEN
N
STOP
MAX
GATE SPEED
MIN
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
OPEN
COM
CLOSE
GATE
STATUS
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
RADIO GND
GND
RADIO SIG.
NO LIMIT SWITCH/CLAMP SLIPPING LED: Will light when the release handle clamp is
slipping on the output shaft. The learned gate OPEN and CLOSE positions will NOT be correct
when the limit tabs keep changing position.
ENTRAP
CLOSE TIMER
FIRE DEPT
GND
MAX OPEN
GND
NO LIMIT SWITCH /
CLAMP SLIPPING
EDGE 1
MAX
OFF
NO LIMIT SWITCH/CLAMP SLIPPING LED: Will light when either limit switch
does NOT activate from it’s learned positions.
Tamper NO
COM
GND
Tamper IN
BATTERY
IN USE
POWER
24V
GND
MOTOR OVERLOAD LED: Will light when excessive current is being drawn
by motor caused by damaged gate hardware or gate is too heavy.
ANTI
TAILGATE
33
matrix 1
external Open/Close key switch - optional
An Optional External Open/Close Key Switch can be connected that allows dual gate operators to be electronically moved
open or closed at the same time by wiring both operators to the external key switch.
Connect (3) three wires from each MAX MC-200 Motor Controllers to an External Open/Close Key Switch depending on your
specific installation, see below.
Key Switch
Close
Terminal
Gnd
Gnd
OUTSIDE Property
OUTSIDE Property
PRIMARY
SECONDARY
PRIMARY
SECONDARY
INSIDE Property
INSIDE Property
OPEN LEFT
OPEN RIGHT
Primary Open RIGHT
Primary Open LEFT
C C
o n -2
tr 0
oll 0
er
M
R
E
oto
r
ap
O
W
M
P
E
ntr
U
L
e
C
ell
E
dg
ho
to
P
1
e
W
2
E
dg
O A
N TR
-L IX
IN
E
R JO
IG G
H
T
J
LE OG
F
T
D
M
A
X
S E
en R
sit D
iv
ity
S
it
LE
TO pu us
oto
ONI to in y un
Ph 3. OP
1.M red An
d/or or ST
wi ned.
an t 2 N & rix 1 .
d.
pu
learpere Edgeer in OPE Mat gins
be
g
jum rsin eith the e onode
ve d to LD e timn m
2.Re wire d HO sam lear
be s an the ard,
N
es at he MOTIO
3.Pr ttonsep is TOR
MO
bu be
E
til
OS
ted
un
CL
dica
OP . in
ST 5 min
ed
r
EN
tect ON
de
OP sts fo
ch L be
la
e
r ea WIL
mod
N fo Ds al
arn ing. O LE du
in.
Le ep L be200. en
5m
wh
be
by WIL MC- 0s
thin ode,
Ds on C-20 .
n wi n m
4.LEnsorTH Me used agai lear
d
n
se BO ar tto en
s
for ator P bus and
D.
O
er
RE
op s ST nsor
TO
es n se s. ONI
5.Pr lear g stop w M
to in e no
ep ar
be ts
Inpu
3
2
R
TO
MO
1
O M
ve o
rL tor
oa
d
D
R
E
MC-200 Swing
N
Jo
Jo g
g LT
R
E GN T
E dg D
d e
P ge 1
ho 2
C to
ell
Jog LT Jog RT -
GND Edge 1
ey T
s
TO
InpuONI inpu nsorRE th MUS
N
M
n
ts
D Se FO pu
to
AR
ll ca
RE ts BEed in
LE
Ce
To
r In
we
Po
SW
AR
AL
M
-
M
IX
TR
MA
n
tio
tec
ro r
t P pe
en jum
pm UST
”
tra : M
ED
En ts puts
RN
3 Inpued in
EA
“L
us
T be
un
MUSors. :
3
be be
3
ns
2 & R se 2 & MUST can be
ts
ts
-
Secondary
r
2
16
15
RS-485 (+) RS-485 (-) GND PWR 24V -
MO
TO
R
ry
ma
Pri -200
C r
X Mtrolle
A
M on
rC
oto
14
GND PWR 12V -
r In
Se
c
MA onda
X r
Mo MC y
tor -20
Co 0
ntr
oll
e
.
ns
ctio
stru tion.
n in stalla
tio
alla e d’in
inst
tic
d
See la no
ore
on
ir
N:
nit ng
cti
IO N: Vo
Mo ersi
UT
rotenes E 1 or
P
CA NTIO
t
li
Rev e
en ide EDG
TE
g
AT
Ed
pm Gu d ton.
ire
tra or
En ens be wfunctio (N.C.) ch
OR
S UST OT
D to ea ors
d
E
at
re
,
S
M N
o
or ILL CLO NLY oper
nit
ns
Y s O dual
Mo to
se or W
or n
n
o
ns
• A erat RMALL
l ca
Ph l
se whe
op
Cel
NO ED 00
to
Cel
ire OR C-2
Phoputs. to
• WONITor’s M
d/or In
ed
M at .
an e 3
us
er
op used dge of th T be
E
GND
ed
are sing ANY MUS ors.
us
er d to
V sens n
ev
ai
12
T be
• R wire PWRORED T remcur.
US
be 00
VM
NIT MUS ill oc
n
12
C-2 MO
tio
R
ts t w
• M wer inpu faul
PW
otec
po ED D or
t pr12V
-200
S E
R
MC
NU ER
menWR
TO
• U MP
MO TS
trap00 P
PU
en -2
JU
IN
Y
ER
wer MC
TT
po ith
BA CK
LY s w
PA
IT
ON or
LIM CH
ns
IT
se
1
12 13
R
we
E
W
Po
O
-
MO
IN TOR
PU
TS
2.Re pere y BE s
ve d. unus FOREMUS
be rsin
T
ed
inputhey be
3.Pr wire g Ed
ts can
es d to ge
MUS be
bu s an eith and/
tto
T be
un ns d HO er in or Ph
til at
be the LD thput 2 oto
ep
Ce
is hesam e OPEor 3. ll ca
n
ard,e tim N
MO
leare on & ST
TO
R MO
n m Mat OP
rix
TIO
od
N
e be 1
Le
gins
ar OP
.
by n m EN
4.LE beep ode STOP
Ds in lasts
CL
OS
se W g.
for
E
ns IL
5m
for or on L be
in.
op BOTH MC- ON
indi
ca
5.Pr erator M 200. for ea
ted
Ces s
20 LE ch
to s ST are 0s Ds de
us wh W te
le
ed
be arn OP
IL ct
ep se bu . en du L beed
tto
Inpu ing nsor n
al
ON
ts stop s an agai
are s.
d en n wi
no
d le thin
wM
arn 5 m
ONI
mod in.
TO
RE
e,
D.
P
-
PW
R 12
ON
VM
US
se LY po
T be
ns
ors wer
us
with en
ed
tr
MC apm
-200 en
t
PW prot
R 12ectio
AL
V n
AR
p
r
GND PWR 12V -
RS-485 (+) RS-485 (-) GND PWR 24V -
00
En
tra
00 er
-2 ll
C tro
M Con
Edge 2
Photo Cell
5 4 3
UL
oto
GND
1 2 3
LI
SWMIT
ITCH BA
TT
PA ERY
CK
Ed
ge
Ed
ge
En
Ph
otoC
Inptrap
ell
un uts men
us : M t P
ed U
inpuST rote
ts jumpectio
Inpu
r n
to ts 2
M
To ONI & 3
LE TO MUS
1.M AR R se T
N in ns be
O
wireNITO pu ors. “LEA
ts
RN
lear d to RED
2&
ED
in
jum ned. putsSens 3 :
”
An
or
O
Mo
R
Ph nitore
o
Cel to d
l
MC
-2
M
ONMAT
-LINRIX
E
2
Lim
it SW
3
M
2
1
Mo
Revnitore
Ed ersi d
ge ng
1
1
O
G T
JO H
IG
R
fu to
er O ALL
are ator RED Y C nctio EDG
’s M se LO
n.
E1
C-2 nsor SE
or
00 s O D (N
be ersing
whe NLY .C
w
n du , to .)
• M ired toEdg
al each
e
C
op
po -200 ANY and/
erat
w
or
P
ors
• UN er MOWR 12of the Photo
3 In C
NIT V
JU USE
el
MP D in ORE MUS puts l ca
n
D se T be .
ER pu
ED ts M
ns us
ors. ed
or US
faul T
to
t w rem
ill oc ain
cu
r.
M
• Revused.
1
N
E
OP
Jog LT Jog RT -
GT
JO EF
L
LE
X
A N
M DO
tio
ir la
n
En
no instru
tra
tice
ct
p
•A
d’in ions
se Se me
.
stal
op nsor nso nt P
latio
er
MU r G rote
n.
• W ator W
ST uid
cti
ire
MO NO ILL Nbe w elin on
OT ired es
op NIT RM
Lim
15 16
U
AT TION
TE
:
NT See
IO
inst
N:
Vo alla
AT
RIX
LT
g T
Jo g R D
Jo GN e 1
2
dg e
E dg to
E ho ll
P e
CM
5 4 3
MC-200 Swing
D
e
D ity
R iv
E nsit
R
S
E
r d
oto oa
M rL
ve
14
E
OS
CL
O
12
13
IMPORTANT:
The External Open/Close Key Switch WILL override
GATE DISABLE switch/timer device when turned
ON but the GATE TAMPER relay WILL be activated.
MAX External Open/Close
Key Switch
22 AWG Min.
3-conductor twisted
pair, shielded cable
OPEN RIGHT
Edge 2
Photo Cell
OPEN LEFT
CA
Close
Terminal
Open
Terminal
GND Edge 1
Open
Terminal
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
Primary
MAX MC-200
Motor Controller
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
Key Switch
Secondary
MAX MC-200
Motor Controller
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
Secondary
MAX MC-200
Motor Controller
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
Primary
MAX MC-200
Motor Controller
Primary
MAX External
Open/Close
Key Switch In a
Secure Place
3 Wires to Key Switch
3 Wires to Key Switch
34
Adjustments
Approximate OPEN and CLOSED
limit tab positions.
open and close limits
The limit tabs need to be set BEFORE the gate can be cycled or DAMAGE could occur.
IMPORTANT: Manually Release arm and move the
gate to the desired OPEN and CLOSED positions to
adjust the limit tabs. Make sure power is ON.
CLOSED LED
n
itio
Pos
sed
lo
mC
Ar
CLOSED Tab
Activated
Position
Breather Pin
E
ity
itiv
ns
4 3
5
Se
or d
ot oa
M rL
ve
O
D
R
E
R
D
12 13
14
16
15
GT
JO F
LE
X
A ON
M LED
G T
JO H
IG
R
ON-L
ge
oto
2Se
MA
LO G
CK
c
CO
M
NC
Y
GA
TAM TE
PER
Tam
per
NO
CO
M
Tam GND
per
IN
MA
TR
BO IX
AR
D
ERY
PACK
ALAR
M
LIMIT
SWIT
CH
BATT
MOT
OR
INPU
TS
ED
GE
1
ED
GE
2
ID
PL
ER UG
RO
R
CL
OS
ERS
E
E SEN
SITI
MOT
VITY
OR
OVE
RLO
NO
AD
LIM
CLA IT
MP SWI
SLIP TCH
PIN /
G
UL
GA
STA TE
TU
S
ALAR
ALAR
M
M 12V
RE RET
SE
GN T
D
OP
EN
CO
CLOSM
E
(+)
GND
(-)
E
ry
Vo
1/2
Off
11
AC
5V
3A
n
itio
en
Pos
Ar
nom
WE
R
OPEN LED
OPEN Tab
Activated
Position
p
mO
x
ma
CLOSED
LOSE
LIMIT
lta
ge
F
MA
X
tery BC
Arm
OPEN
LIMIT
O p e n i n g D ir e ct
ion
Bat
Mod
TES
Bat T
tery
Open LEFT
-7
ule
LED
lights
Bat
tery
Erro IN
r
lig
ON
/OF
Bat F
tery Rep
lace
Bat
tery
IMPORTANT:
Remove breather
pin from gear
reducer BEFORE
cycling operator.
tion
tec
pro
ed the
tinu with
con only e.
fus
: Forlace of
pas les
ING rep ng
r ne treible
RN fire, rati
pou con
WA inst e and
tion fus
aga e typ MENT: tec r un es
tiqu
SE la proutiliseéris
sam
TIS ttre die, act
ER
car
AV prome cene et
d’in
comues s typ
risq me .
mê
de inales
p
7 Am
SE
FU
On R
WE
PO
BATTE
IN RY
US
E
PO
24V
GND
(+)
GND
(-)
SEC
GAT
E
OPEN
STOP
CLOSE
COM
GATE DISABLE
RADIO SIG.
RADIO GND
STRIKE
GND
KEYPAD
/ RDR
GND
PHOTOC
ELL
GND
FIRE DEPT
GND
MAX OPEN
GND
ENT
RAP
STOP
REV
LIM
SW IT
ON- ITCH
LIN
E
MO
ON- TOR
PRI
LIN
MAR
E
GAT Y
r In
TIO
N
EN
SP
EED
we
ELL
MO
TO
R
X
GA
TE
Po
PH
OT
OC
UL
OP
MA
MIN
MAX
E
R
E
W
ll
Ce
FET
O
P
Ph
TO
R MO
OBD
BLA POR
CK T
BOX
Ba
tte
p
Ed
1.5S
ec
MO
PO
RE SITION
CO
RD
ER
24V
DC
tra
SA
ER
00 r
-2 le
C trol
M Con
En
MA
GL
DE OCK
LAY
LS
PAR
OPETIAL
N
or
ot
RO
12V
DC
GND
GND
2
OFF
NT
OFF MAX
E TIM
UL
CO
MIN
CLOS
ID
PLUG
M
SW
SE
RS-485 (+) RS-485 (-) GND PWR 24V -
ETY
1
/CLO
EXIT
OFF
TER
OPE
RIG N
HT
CENT
ER
SAF
ge
it
Lim
OPE
LEF N
T
RE ION
MO
BE VE
OP FORE
ER
AT
ION
Ed
ON
CEN
PR
IM
GA ARY
TE
OPE
1 TIMN
E
OP
EN
IX
INE
LEA MODE
LEA
VE
OPEVE CLOSED
N
TO
MAT
IC
AN
TAI TI
LG
ATE
TR
BA BATTE
CK
-UP RY
USA
AU
UT
MA
MAD
E in
CA
Jo
Jo g
g LT
R
E GN T
E dg D
dg e
P e 1
ho
C to 2
el
l
MAT
RIX
1
EXIT
Limit Tab unti
l LE
tate
Ro
D
ADJUST LIMITS:
Manually Release Arm
1. Move gate to OPEN position.
2. Loosen open limit tab screw.
3. Rotate open limit tab until open
LED lights.
Arm
s
ht
CLOSED LED
Clo
sed
CLOSED Limit
switch contact
point.
Arm in CLOSED
position
Pos
itio
n
CLOSED Tab
Activated
Position
EXAMPLE:
Operator
Opens RIGHT
OPEN LED
4. TIGHTEN open limit tab screw.
Arm
5. Move gate to CLOSED position.
6. Loosen closed limit tab screw.
7. Rotate closed limit tab until closed
LED lights.
Limit
Tab Screw
8. TIGHTEN closed limit tab screw.
CAUTION
IMPORTANT: Manually Secure Arm (see page 36)
Cycle the gate OPEN and CLOSED after the limit
tabs have been set AND the arm is SECURE.
Operator will cycle slowly to LEARN the open and
closed gate positions. After the operator learns
the gate positions, it will cycle at the GATE SPEED
selected for normal operation.
ERD
JOG
JOG
LEFT RIGHT
Sensitivity
5
4
3
ERD
MAX
12
16
13 14 15
LED ON
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
“Fine Tune” Limits Adjustment
Motor
OverLoad
OPEN Limit
switch contact
point.
Make sure OPEN/CLOSE
limit rings are tightened
after adjustment or
slippage could occur.
O p e n i n g D ir e ct
Pos
itio
ion
n
Open RIGHT
LED Indicators
EN T
OP IMI
L
ED
OS IT
CL LIM
itch
t Sw
imi
L
pen
itch
t Sw
imi
Clo
Arm in Closed Position
Short Arm
Motor Controller
POWER
Limit SW Edge PhotoCell
en
Arm
L
sed
ON-LINE Edge UL Entrap
1
2
Op
O
MC-200
MATRIX
OPEN Tab
Activated
Position
Positive Stop
1/4” gap
on Long Arm
Push and HOLD the JOG LEFT or JOG RIGHT buttons
accordingly on the MAX MC-200 motor controller to
IMPORTANT: DO NOT allow
move the gate (release the button to stop gate). This
positive stop on long arm to
allows gate to be moved back and fourth without leaving touch short arm in closed
the operator to “fine tune” the open and close gate
position. Leave about a 1/4” gap.
positions if desired.
WARNING: Avoid the moving arm while “Fine Tune” adjusting.
Limit
Switch Box
IMPORTANT: LEDs MUST light up
when gate reaches OPEN and
CLOSE positions or operator WILL
NOT learn gate positions. If gate
positions are not learned, gate
cycling speed will remain slow
during normal operation.
35
Adjustments
release handle clamp
Adjustment:
factory set bolt
DO NOT adjust
Tighten the Adjustment bolt until desired result is achieved.
The release handle clamp has been factory adjusted and
SHOULD NOT need any adjustment.
lt
st bo ip
adjufirm gr
for
IMPORTANT: The red handle MUST BE FIRMLY secure in the
HORIZONTAL position.
Adjustment
Bolt
NO
Release Handle Clamp MUST be
HORIZONTAL when FIRMLY secured.
Rele
ase H
andl
e Cla
mp
IMPORTANT: The arm MUST NOT slip
when the gate is cycling or the gate OPEN
and CLOSE limit positions will NOT be
LEARNED. Gate speed will remain slow if
gate positions are NOT learned.
Re-Attach to Operator:
Limit pin MUST fit into slot in bottom of
release handle clamp directly under the
arm when reattaching arm to operator.
Arm
Slot
Limit Pin
Limit Tabs
36
After Release Handle Clamp is in the SECURE HORIZONTAL
position:
Pull the arm. NO slippage should occur.
If it does, readjust.
NOTE: When limit tabs are already set and the release handle is put
back in the secure position but the gate is NOT in the full open or close
position, the operator will automatically re-align the gate’s open and
close tabs. No readjustment is necessary.
Adjustments
reverse sensor (erd)
This operator is equipped with an ERD Sensor - Electronic Reversing Device (Type A) that functions as entrapment protection
according to UL 325 standards. The gate will reverse direction after encountering an obstruction in either the OPEN or
CLOSE gate cycle.
When the gate encounters an obstruction during the CLOSE cycle, it will reverse to the open position and PAUSE the gate. An
input command (press remote button or exit loop) is needed BEFORE the gate will reset and close again.
When the gate encounters an obstruction during the OPEN cycle, it will reverse approximately 6 inches and PAUSE the gate. An
input command (press remote button or exit loop) is needed BEFORE the gate will reset and open again.
For the ERD Sensitivity to function correctly:
ERD
JOG
JOG
LEFT RIGHT
Sensitivity
Motor
OverLoad
5
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
• THE RELEASE HANDLE CLAMP MUST NOT SLIP when the gate encounters an obstruction.
• Limit switches must be learned BEFORE adjusting the ERD Sensitivity.
4
MC-200
1
2
3
MAX
ERD
12
16
13 14 15
LED ON
TIP: While Adjusting ERD. . . . .
Motor Controller
MATRIX
ON-LINE Edge UL Entrap
POWER
1
Limit SW Edge PhotoCell
STOP Gate
Half-way
16 sensitivity setting positions.
NO mechanical hard stop for knob.
Adjusting ERD Sensitivity
ERD
Sensitivity
5
4
3
12
16
16
13 14 15
5
A. Turn knob until blue LED lights up.
Max sensitivity reached, Position 1.
“1” - Maximum sensitivity setting.
Too sensitive for most gates. (LED lights)
M
MAX
LED
LE
L
ED ON
E
“16” - Minimum sensitivity setting.
Not sensitive enough for most gates. (LED is off)
ERD
Sensitivity
5
3
2
CLOSE Gate
B. Turn knob counter-clockwise to reduce
sensitivity during ERD testing as needed.
(LED remains OFF for all but position 1)
4
Position gate half-way open and STOP gate.
This gate position will put the most amount of
resistance on the ERD sensor when gate cycles.
MAX
12
16
13 14 15
LED ON
CLOSE gate. If ERD sensor triggers, reduce
sensitivity. If sensor does NOT trigger,
sensitivity is set correctly.
Testing ERD Sensitivity
Allow the gate to strike an immobile object while OPENING and
CLOSING. The gate MUST reverse direction after striking the object.
Increase or decrease the ERD Sensitivity as needed. Repeat this
process until the correct sensitivity is achieved. If alarm sounds
External Alarm
while preforming this procedure,
Reset Button
Matrix
1
press STOP BUTTON on Matrix 1
MOTOR MOTION
or externally mounted Alarm
S
ES
Reset button to shut-off alarm.
PR
OPEN
STOP
CLOSE
IMPORTANT: When satisfied with ERD adjustment,
cycle the gate 3 or 4 times to make sure that the ERD
sensor does not falsely trigger during normal gate
operation. Readjust if this happens.
to
T
SE
RE
“Min” ERD Position 16 Setting
When solid gates are installed in:
• Unusually high wind areas
• Uphill opening gate
• Heavy gate
ERD sensor can be set to Min (position 16)
to keep the gate cycling normally in such
extreme conditions.
CAUTION: Minimum sensitivity setting
(position 16) results in gate exerting
MAXIMUM force before reversing direction.
37
maintenance
qualified gate operator technician
Maintenance and repair of the gate operator must be preformed by a qualified professional gate operator technician.
The following services need to be periodically performed:
• Check and adjust the gate operator’s force, speed, and sensitivity.
• Make sure all power (AC/DC) connections are corrosion free.
• Check all batteries for proper voltage.
• Check the incoming line voltage and confirm it is within 10% of its rating (115 or 230 volts).
• Verify battery backup functionality by turning off the power source (115 VAC and 230 VAC). Restore power after testing.
• Cycle gate system and lubricate with heavy-duty, high-performance lubricant where needed.
• Test all contact and non-contact sensors, in-ground vehicle loop detectors, keypad, telephone entry system or any other access
control devices that are used to control the gate operator.
• Test the manual release feature.
MAKE SURE END USER/HOME OWNER KNOWS HOW TO PROPERLY REMOVE GATE OPERATOR FROM SERVICE AND WHO TO
CONTACT FOR PROFESSIONAL ASSISTANCE.
Date Installed:
Installer/Company Name:
Phone Number:
Operator
Serial Number:
end user / homeowner
Any repairs and modifications must be preformed by a qualified professional gate operator technician. If the gate or gate
operator ever malfunctions, end user/home owner needs to immediately remove the gate operator from service (manually
position gate (see manual release) in a desired prolonged position and turn ALL power OFF to the gate operator). End
user/home owner must call a qualified professional gate operator technician for any repairs and modifications.
The gate operator is virtually maintenance free to an end user/home owner, minimal maintenance is recommended to ensure
reliable operation.
End user/home owner:
• Scheduled maintenance should be performed approximately every six months by a qualified professional gate operator
technician, or when unusual noises are heard from the gate hinges and/or gate operator arm.
• DO NOT remove the operator cover to perform any normal maintenance.
• Lubricate gate hinges and gate operator arm periodically with heavy-duty, high-performance lubricant and clean up all excess
lubricant.
• Make sure there are no vehicles or pedestrians in the path of the gate while performing maintenance.
• Make sure the person performing maintenance is the only person in control of all control devices in order to avoid possible
involuntary activation of the gate operator. Gate operator MUST be removed from service while maintenance is performed.
• Keep any water from landscape watering hoses or sprinkler systems away from the gate and gate operator area.
• Keep the area around the gate and gate operator as clean as possible.
• Keep any debris away from the gate’s swinging path.
• Test periodically (use caution) all safety sensors, in-ground vehicle loop detectors, keypad, telephone entry system or any
other access control devices that are used to control the gate operator. Make sure everything is working properly.
• Solar panel must be cleaned periodically if solar power is being used.
38
Maintenance
megatron primary wiring schematic
Matrix 1
MAGLOCK
DELAY
2Sec
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ON
EXIT
CENTER
GATE
TAMPER
SAFETY
OFF
Input AC Power
115VAC or 230VAC
Tamper NO
COM
GND
Tamper IN
MIN
UL
EDGE 1
ENTRAP
EDGE 2
Solar
Panel
Electronics
Box
MAX
OFF
CLOSE TIMER
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
POSITION
RECORDER
12VDC
OBD PORT
BLACK BOX
24VDC
STOP
MIN
CLOSE
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
OPEN
COM
CLOSE
GATE
STATUS
SEC
GATE
(+)
GND
(-)
BATTERY
IN USE
POWER
24V
GND
PRIMARY
GATE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LIMIT
SWITCH
ON-LINE
MOTOR
ON-LINE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO GND
GND
RADIO SIG.
WARNING: For continued protection
against fire, replace only with the
same type and rating of fuse.
REVERSE SENSITIVITY
to POWER/SOLAR IN
GND
OPEN
MAX
GATE SPEED
UL ALARM 12V
ALARM RET
RESET
GND
7 Amp
FUSE
AVERTISSEMENT: pour ne pas
compromettre la protection contre les
risques d’incendie, utiliser un fusible
de mêmes type et caractéristiques
nominales.
On
POWER
Off
115VAC 3A max
Black
SAFETY
“Optional”
MAX Solar
Power Kit
White
PHOTOCELL
Green
CENTER
MAX
Megatron
Toroid
Box
www.Max.US.com
POWER
IN
Battery
Pack
TO MOTOR
CONTROLLER
MAX BC-7
Battery Module
POWER/SOLAR
IN
BATTERY
IN
Motor
Alarm
5-Pin
4-Pin
3-Pin
MOTOR Power In
6-Pin
OPEN
LIMIT
2-Pin
3-Pin
CLOSED
LIMIT
MOTOR BATTERY LIMIT ALARM
PACK SWITCH
INPUTS
MAX MC-200
Motor Controller
GND PWR 24V -
ANTI
TAILGATE
EXIT
RS-485 (-) -
OFF 1.5Sec
MAG
LOCK
RS-485 (+) -
OPEN
RIGHT
Junction Box
OPEN
LEFT
OPEN
1 TIME
GND PWR 12V -
LEAVE
CLOSED
LEAVE
OPEN
MADE in USA
Solar Panel 24V
PRIMARY
GATE
BATTERY
BACK-UP MODE
not used not used -
MATRIX 1
MATRIX 1
Limit Switch Box
39
Maintenance
megatron secondary wiring schematic
Solar Panel 24V
Input AC Power
115VAC or 230VAC
Junction Box
to POWER/SOLAR IN
7 Amp
FUSE
AVERTISSEMENT: pour ne pas
compromettre la protection contre les
risques d’incendie, utiliser un fusible
de mêmes type et caractéristiques
nominales.
On
POWER
Off
115VAC 3A max
Black
WARNING: For continued protection
against fire, replace only with the
same type and rating of fuse.
White
Solar
Panel
Electronics
Box
Green
“Optional”
MAX Solar
Power Kit
MAX
Megatron
Toroid
Box
www.Max.US.com
POWER
IN
Battery
Pack
TO MOTOR
CONTROLLER
MAX BC-7
Battery Module
POWER/SOLAR
IN
BATTERY
IN
Motor
Alarm
Limit Switch Box
40
GND PWR 24V -
RS-485 (-) -
RS-485 (+) -
MAX MC-200
Motor Controller
GND PWR 12V -
MOTOR BATTERY LIMIT ALARM
PACK SWITCH
INPUTS
not used not used -
5-Pin
4-Pin
MOTOR Power In
3-Pin
OPEN
LIMIT
6-Pin
CLOSED
LIMIT
2-Pin
3-Pin
To “SEC GATE” input
on Matrix 1
MATRIX 1
maintenance
manual gate release
1
Make sure ALL power is OFF to operator.
Hood
2
Removable Key
Factory Installed Lock
OR
Optional Non-Lockable Latch
Unlock or unlatch
hood and remove it.
WARNING
Pinch Point
NEVER grasp the
Arm
arm to move gate!
3
Pull red handle up
and move gate.
DO NOT Lift Arm
OFF of Operator
Arm
ALWAYS grasp gate to move it.
olt
st b rip
adjufirm g
for
41
maintenance
electronic gate open / close - Optional
E
OS
The OPTIONAL external key switch device (sold separately) can open or close the
gate electronically if the switch has been wired to the MC-200 motor controller.
CL
Insert key on control box, turn and HOLD (in either direction) to MOVE gate.
CAUTION: Keep pedestrians and vehicles clear of the gate while it is moving.
EN
OP
audible alarm
If the Alarm Sounds During Normal Gate Operation: When the gate encounters
TWO consecutive obstructions before completing a gate cycle, the alarm will sound and
the gate will PAUSE in the position where the second obstruction occurred. CHECK THE
GATE AREA FOR ANY PROBLEMS BEFORE pressing the STOP button on the Matrix 1
or the externally mounted Alarm Reset button to shut off the alarm and reset the gate.
NOTE: Alarm will automatically shut-off after five minutes but will not allow gate to
operate until the STOP button is pressed.
Alarm Shut-OFF
MOTOR MOTION
STOP
OPEN
CLOSE
Matrix 1
STOP Button
Some reasons why the alarm sounds:
• HINGES are TOO TIGHT or BROKEN, gate CANNOT move freely.
• Gate is STUCK or BENT in an awkward position.
• A FOREIGN OBJECT is on the gate frame while the gate is moving.
• The gate is TOO HEAVY.
OUTSIDE Property
Externally Mounted
S Alarm Reset Button
ES
PR
shuts-off alarm.
ET
ES
R
to
INSIDE Property
Gate is Closing
• The gate operator tries to close the
gate but gate gets CAUGHT on an
object and cannot move.
42
Moving Vehicle is Entering
• The moving gate gets PUSHED by a moving VEHICLE.
maintenance
1
replacement parts list
Camlock Assembly with cover and key
Plastic Hood
Hood Latch Bracket
Output Clamp Assembly
Swing arm T-Bar
Operator cover - MAX Megatron 1400/2200/FAST
Door for cover
Output collar and rings
Output Shaft for MAX Megatron 1400 & HP
Output Shaft for MAX Megatron 2200/FAST
Double Gear Box MAX Megatron 2200 (Silver)
Double Gear Box MAX Megatron FAST (Yellow)
Double Gear Box MAX Megatron 1400 & HP (Gray)
DC Brushless Motor
Swing Arm Assembly
Limit Switch Box
Chassis MAX Megatron 1400/2200/FAST
MAX Megatron Toroid Box Power Supply
Alarm
MC-200 Motor Controller (Megatron)
Matrix 1 Control Board Assembly
BC-7 Battery Module (7Ahr)
Single Gang Box
Operator cover - MAX Megatron 1400HP
Chassis MAX Megatron 1400HP
3
15
4
5
6
7
8
9
10
12
13
11
14
24
16
nsi
20
D
ty
ER tivi
Se
or d
ot oa
M rL
ve
O
D
ER
5
14
4 3
12
13
15 16
G
JO FT
LE
X
A ON
M LED
Jo
Jo g
g LT
RT
Ed GND
Ed ge
Ph ge 1
Ce oto 2
ll
G
JO GHT
RI
MATR
-LIN
ON
IX
E
Edge
Limit
1
SW
ER
W
PO
00 r
-2 lle
C ro
M Cont
Entra
p
or
ot
Photo
Cell
M
2
UL
Edge
17
MA
BOTRIX
AR
D
RS-485 (+) RS-485 (-) GND PWR 24V -
MA
TR
ALAR
M
1
LIMIT
SWITC
H
BACBATTER
K-U Y
P
LEAV MODE
LEAV
OPENE CLOS E
ED
OPE
LEFTN
OP
EN
ON
EXI
OFF
CENT
r In
ANT
TAI I
LGA
TE
EXIT
21
ER
/CLO
OPE
RIG N
HT
SE
T
CEN
CO
OFF
NT
RO
TER
TY
ec
2Sec
MA
LOCG
K
SAF
ETY
COM
NC
OFF MAX
SE
TIM
GAT
TAM E
PER
ER
TIO
OBD
BLA POR
CK T
BOX
(+)
GND
(-)
OPEN
STOP
CLOSE
COM
GATE DISABLE
SEC
GATE
ALA
ALA RM
RM 12V
RESRET
ET
GND
OPE
N
COM
CLO
SE
GATE
on
ecti
prot
ed the
tinu with
.
con only
fuse
: For ace of
pas les
NG repl g
r ne treble
RNI fire, ratin
pou on con
WA inst and
fusi
aga e type MENT: ecti un ues
prot ser istiq
sam SSE la utili
RTI ettre die,caractér
AVEprom cen et
d’in
comues type
es
risq
mêmes.
de inal
nom
ww
w.M
ax.
US
.co
m
Bat
tery
E
ELL
EDG
E1
EDG
E2
ID
PLU
ERR G
OR
UL
GAT
STA E
TUS
BAT
TER
IN Y
USE
24V
GND
STRIKE
GND
KEYPAD
/ RDR
GND
PHOTOCEL
L
GND
RADIO SIG.
RAP
CLO
SE
SENS
ITIVI
MOT
TY
OR
OVER
NO
LOAD
LIMI
CLAM T
SWIT
P SLIP CH
PING/
LIMI
SWI T
ON-LTCH
INE
MOT
PRIM ON-L OR
INE
ARY
(+)
GND
(-)
RADIO GND
OPE
N
X
STO
P
GAT
E SPE
REVE
RSE
ED
TOC
Vol
1/2
tag
e
MC
To R IN
WE
PO
p
7 Am
SE
FU
F
MA
MIN
MAX
FIRE DEPT
GND
MAX OPEN
GND
ENT
N
ry
tte
Ba ck
Pa
MO
ER
W
PO IN
TOR
OR
OT ER
M LL
TO RO
NT
GND
PHO
UL
MO
POS
REC ITIO
ORD N
ER
CO
Tam
per
NO
COM
Tam GND
per
IN
PAR
TIAL
OPE
N
C
C
Y
ER
TT
BA IN
MIN
CLO
ID
PLU
G
12VD
GND
24VD
18
MA
GLO
DEL CK
AY
1.5S
LS
SAFE
AR
OL
/S
ER
W IN
PO
25
PRI
MA
GAT RY
E
OPEN
1 TIME
Po
we
USA
AU
TO
MA
TIC
MO
TO
R
E in
BATTE
RY
PACK
IX
MAD
INPU R
TS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
2
Description
MOTO
Item
ON/
OFF
Batt
ery Rep
lace
Batt
ery
On R
3A
WE
AC
PO
5V
11
Off
x
ma
MA
Batt X
ery
TES
Batt T
ery
BC
Mod -7
ule
Batt
ery
Erro IN
r
MC ck
To Pa
ry
tte
Ba
22
19
23
POW
ER
43
max megatron warranty
Maximum Controls LLC (“Manufacture”) warrants the original purchaser of this
product, for the purpose to which this product is originally installed, that the product is
free from defect in materials and/or workmanship for a period of 8 years for the
Brushless DC Motor and cover, 5 years for everything else with the exception of the
batteries which are limited to a 1 year warranty. The performance of this product is
dependent on compliance to the instructions, maintenance, operation, and testing
clearly outlined in the user manual. Failure to comply completely with those instructions
will void this warranty in its entirety. This warranty does not cover damage to the
product caused by vandalism, water damage, direct hit lightning strike, or installation
errors. This warranty does not include any labor charges that might be needed to
troubleshoot, replace, or repair a problem.
If, during the limited warranty period, one of the components exhibits a defect in
material and/or workmanship, please call 949-699-0220 before dismantling the product.
Shipping instructions and an RMA (Return Material Authorization) Number will be
issued by the factory service center when contacted. Do not send any product in for
service without an RMA number. Shipping charges to and from the factory service
center for warranty repairs are the responsibility of the customer. Repair or replacement
of any warranty items is made at the sole discretion of the Manufacturer.
ALL IMPLIED WARRANTIES FOR THE PRODUCT, INCLUDING BUT NOT LIMITED TO
ANY WARRANTIES OF MERCHANTABILITY AND SUITABILITY FOR A PARTICULAR
PURPOSE, ARE LIMITED TO 8 YEARS FOR THE BRUSHLESS MOTOR DC AND COVER,
5 YEARS FOR EVERYTHING ELSE WITH THE EXCEPTION OF THE BATTERIES WHICH
ARE 1 YEAR. NO IMPLIED WARRANTIES WILL EXTEND BEYOND THE WARRANTIES
LISTED ABOVE. Some states do not allow limitations on how long an implied warranty
last so this limitation might not apply to you.
This Limited warranty does not cover any problems with or relating to, the gate, the gate
hardware, including but not limited to hinges, rollers, brackets, entry devices etc. Any
service call that determines the cause of a problem to be external to the product could
result in a fee. Under no circumstances shall the manufacture be liable for
consequential, incidental or special damages arising in connection with the use, or
inability to use, this product. Under no circumstances will the Manufacture’s liability for
breach of warranty, breach of contract, negligence or strict liability exceed the cost of
the product covered other liability in connection with the sale of this product.
44
megatron options / unique Features
“Like NO other Gate Operator in the World”
gate tamper feature
The GATE TAMPER feature will activate the relay when a number of security circumstances occur, making illegal entry almost
impossible when the gate operator is connected to a existing building/home alarm system. The GATE TAMPER relay will activate
when:
The gate is PHYSICALLY moved from the
closed position with EXTREME force.
The red release handle clamp is lifted and
the gate is pushed open from the closed
position without authorization.
The FIRE switch is turned ONLY if
the GATE DISABLE has been turned ON.
45
megatron options / unique Features
“Like NO other Gate Operator in the World”
Gate disable feature
This unique GATE DISABLE feature is useful when the gated area needs to be secured from ALL but emergency and/or authorized vehicle entry. Some examples are:
• Residential home vacation period.
• During closed hours of a business.
The GATE DISABLE feature will allow the FIRE DEPT/MAX and
RADIO inputs to operate but nothing else. It helps with some
major security problems that can occur when no one is
available to monitor the property.
M
Pl etal
at
e
GATE DISABLE
prevents breaking into
a keypad box and
trying to trigger the
wires to get the gate
to open.
EX
IT
LO
OP
GATE DISABLE prevents trying to trigger
the exit loop to get the gate to open.
IMPORTANT: It is NOT recommended activating GATE DISABLE while persons are present inside the property.
event history download
Event History Text Document Sample
Event type clarificaon:
This unique EVENT HISTORY feature has an On Board Diagnostics (OBD)
port to download a simple .txt file to troubleshoot gate operator errors
and to view normal transaction logs. This file will log intermittent
problems with the gate operator that can be difficult to solve. This file
can even be e-mailed to the factory from out in the field at the job site for
additional technical support if necessary.
The event history can store up to 1000 transactions.
USB Flash Drive
MATRIX 1
PRIMARY
GATE
BATTERY
BACK-UP MODE
LEAVE
CLOSED
LEAVE
OPEN
MADE in USA
OPEN
LEFT
OPEN
1 TIME
MAGLOCK
DELAY
OPEN
RIGHT
OFF 1.5Sec
2Sec
ANTI
TAILGATE
ON
EXIT
CENTER
GATE
TAMPER
SAFETY
Fri 07/11/2014 10:59:41
INFO : Cycle Counter
Fri 07/11/2014 10:59:41
ENTRAP : SEC_MC: First ERD Detected
Fri 07/11/2014 10:59:37
INFO : Radio Input Deacvated
Fri 07/11/2014 10:59:36
INFO : Radio Input Acvated
Fri 07/11/2014 10:58:54
INFO : PRI_MC: Fully Open Posion Learned
Fri 07/11/2014 10:58:53
INFO : SEC_MC: Fully Open Posion Learned
Fri 07/11/2014 10:57:40
INFO : PRI_CIO: Communicaon Established
ENTRAP : PRI_MC: Photo Cell Deacvated
COM
NC
Fri 07/11/2014 10:57:34
ENTRAP : PRI_MC: Photo Cell Acvated
Tamper NO
COM
GND
Tamper IN
Fri 07/11/2014 10:57:21
INFO : Radio Input Deacvated
Fri 07/11/2014 10:57:21
INFO : Radio Input Acvated
MAG
LOCK
OFF
Event Report:
Fri 07/11/2014 10:57:38
AUTOMATIC OPEN/CLOSE CONTROLS
EXIT
INFO: informaonal message only
WARNING: unusual event but doesn't cause system malfuncon
ERROR: abnormal event, could cause system malfuncon
ENTRAP: entrapment detecon event
CENTER
PHOTOCELL
UL
SAFETY
MIN
EDGE 1
MAX
OFF
ENTRAP
EDGE 2
Fri 07/11/2014 10:56:46
WARNING: PRI_MC: Tamper Reported
Fri 07/11/2014 10:56:36
INFO : SEC_MC: Fully Open Posion Unknown
CLOSE TIMER
PARTIAL
OPEN
ID PLUG
ERROR
MOTOR MOTION
ID
PLUG
POSITION
N
RECORDER
12VDC
GND
OBD PORT
BLACK BOX
24VDC
OPEN
STOP
MAX
GATE SPEED
MIN
GATE
STATUS
Fri 07/11/2014 10:56:36
INFO : PRI_MC: Fully Open Posion Unknown
OPEN
COM
CLOSE
Fri 07/11/2014 10:56:36
WARNING: PRI_MC: Tamper Reported
BATTERY
IN USE
US
Fri 07/11/2014 10:56:33
ENTRAP : PRI_MC: Photo Cell Deacvated
Fri 07/11/2014 10:56:33
ENTRAP : PRI_MC: Photo Cell Acvated
POWER
24V
GND
SEC
GATE
(+)
GND
(-)
MOTOR
ON-LINE
PRIMARY
GATE
OPEN
STOP
CLOSE
COM
GATE DISABLE
LE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
STRIKE
GND
KEYPAD / RDR
GND
PHOTOCELL
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO GND
RADIO SIG.
GND
46
OBD PORT
BLACK BOX
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
UL ALARM 12V
ALARM RET
RESET
GND
CLOSE
REVERSE SENSITIVITY
Fri 07/11/2014 10:56:33
ENTRAP : PRI_MC: Photo Cell Deacvated
Fri 07/11/2014 10:56:33
ENTRAP : PRI_MC: Photo Cell Acvated
47
48
49
www.max.us.com
CONFORMS TO UL STD 325
UL CLASS - I, II, III, IV
SAFETY SENSORS REQUIRED
CERTIFIED TO CAN/CSA STD
C22.2 NO. 247
T
S
A
/F
14
0
0
0
0
H
2
P
/2
0
0
14
Residential / Commercial
Brushless DC
Swing Gate Operators
Made in USA
4009963
Maximum Controls LLC.
27211 Burbank
Foothill Ranch, Ca 92610
Tel: (949) 699-0220
Max Megatron Version 10.3.16

advertisement

Related manuals