Information Sheet for Builders and Architects

For further information or specifications, visit the technical section of our website www.escea.

com to view the latest product Installation Manual.

Appliance Information

Product Dimensions

All outside dimensions taken from the appliance are with the standoffs attached.

735mm*

Specifications

Heat Output

Star Rating

5-5.6 kW

3-4 stars

Gas Input/Consumption 22-25 MJ/hr

Gas Connection

Gas Type

Weight

Room fan

Flue Type

Flue Size

Power Requirement

Smart Heat App lower right, 1/2” BSP female thread

Natural Gas / ULPG / Propane (Aus)

45 kg

Yes

Simpson Duravent Direct Vent (False Chimney)

Flexi Flue (Masonry)

6” Outer, 4” Inner (Direct Vent)

4” and 3” Flexi Flue (Masonry)

3 pin earthed 230/240V power outlet +isolating switch to be within 1.0m of rear right hand corner of the appliance.

Yes

124mm

*Not including Lid Overhang

505mm

381mm

753mm

368mm* 368mm*

Flue Installation

The freestanding unit and flue system should be installed prior to the AF-Series fireplace being installed (for horizontal termination for FS730: see next page).

□ Place the freestanding unit in the correct location, complying with the clearances specified in the previous section.

□ Remove 2 screws on each side of the fascia just below the top panel and pull towards you to remove the fascia.

Rigid flue

Duravent 4x6”

Rigid Direct-vent flue

□ Fix the FS730 unit to the floor using the four securing holes in each corner of the unit.

□ Refer to Section B3 in the Install Manual for flexi flue and converter box clearances.

□ Refer to section C of the Install manual for minimum and maximum flue lengths, restrictor settings for your installation, and all other flue information.

□ Run the black Ø230mm flue liner lengths from the top of the freestanding unit until it penetrates the Ø265mm ceiling hole.

Flue Liner

Rodent Guard

Ø265 mm

Ceiling hole

□ Use the supplied Ceiling plate for tidying the internal termination point of the

Ø230mm flue liner.

□ Run the 2x flexible flues down through the

Ø230mm flue liner and attach it to the Flue

Spigot Plate as per section C of the install manual

AF700

Fireplace

□ Open the flue liner rodent guard and close around the flexi flue. Rivet, screw or cable tie the open end to prevent it from opening.

Bend the two perpendicular tabs down and screw into the flue liner using a short self tapping screw. Note: Take care when installing the rodent guard to not cause damage to the flexi flue.

□ Install flue termination as per section C of the Install manual

Note: Ensure a power supply is within 1m of the rear of the appliance.

Coaxial to Colinear conversion box

Ceiling Ring

225mm

Flue liner

2x Flexible flue inner

Flexible flue clamped to Flue Spigot Plate

FS730 Freestanding

Unit

630346_1 FS730 Builders and Architects Sheet

Flue Information

Vertically terminating flue diagram Inroom horizontal flue kit

IMPORTANT : Refer to the installation manual for mandatory clearances from the terminal.

Clearances

Flueing Clearances

=

Minimum distance to combustibles

25mm

50mm

25mm

25mm

50mm 0mm*

50mm

50mm ntake

>45°**

Ø75mm I

Ø100mm Exhaust

50mm

50mm

300mm t o

* Note: Underside of converter box can be fixed straight onto wooden joists.

** Note: Flexi-Flue must not be run at an angle greater than 45 degrees from vertical; excluding all appliance built into a freestander kit.

Converter Box Dimensions

78 mm

Hearth and Clearances

A Hearth is not required, however it may be used for decorative purposes or for protection of sensitive flooring. The hearth should not obscure the front face of the fire.

Do not place items or furnishings ontop of the freestanding fireplace, and ensure soft furnishings do not come in contact with the freestanding fireplace.

315mm

175mm

50mm 50mm 50mm

630346_1FS730 Builders and Architects Sheet