- Sports & recreation
- Fitness, gymnastics & weight training
- Sport watches
- Bolt Watches
- ELECTRON
- User manual
advertisement
◉
Touch to zoom
Electron LIGHT (A Key) UP/BARO (E Key) COMP (D Key) MODE/SET (B Key) BOLT WATCHES The Alarm will sound for 20 second with a BELL SYMBOL on the screen, when your set time is reached. • Any Key on the watch will silence the alarm. • Long press the B Key for 3s to exit ALARM mode. • You have the option to set 2 alarms if needed VI. Stopwatch • You will be able to measure up to IV. Data History Query 99:59:59:59. • Your watch will record a full week of data • Enter stopwatch mode. In any mode, press A key to turn on EL history • Press C Key to zero your stopwatch when it backlight for 3s; press B key for 2s to enter • You cannot access data history that if you reaches its max time. its setting mode. have not stored any C Key and D Key can • Press E Key to start/stop your counter. be used to cycle through data history II. Normal Time Display • Long press the C Key to take the counter • The data will automatically reset after 7 days • Long press the B Key for 2s to enter time back to zero. setting mode. You will see the SECOND will • While the stopwatch is running you can press V. Setting the Alarm be flashing and ready to set. If you do not the C Key to create 1 of 99 laps. • To turn ALARM mode on you are going to set the time within one minute of entering press the E Key. Your screen should display this mode it will retain the original setting. a “CHIME” to let you know its been selected. By long pressing the B Key you can enter LAP query mode. This will be invalid if you • Press the E Key to increase seconds/ • Now press the C Key to turn the ALARM don’t have any laps saved. minutes/hours slowly. Long press the E Key mode on/off. • Press the E Key to search your laps in to rapidly increase seconds/minutes/hours. • To set the alarm time long press B Key for 3s ascending order. • Press the C Key to decrease seconds and the minutes will flash. Now a short press • Press the C Key to search your laps in /minutes/hours slowly. Long Press the C Key on B Key will cycle between hours and descending order. to rapidly increase seconds/minutes/hours. minutes. • Press A Key or B Key to exit LAP mode. • To set the LCD contrast you can increase • Use E Key to increases hours or minutes. contrast by pressing the E Key and you can • Use D Key to decrease hours or minutes. decrease by pressing the C Key. Long pressing will cycle through your contrast rapidly in either direction. Contrast is on a 1-10 scale. • Long press the B Key for 3 Seconds to leave time setting Mode. B. Function Display A. Button and Function Overview A Key: Backlight/Reset/Delete Data B Key: Short Press for Function Mode/Long Press for Settings C Key: Altitude Measurement D Key: Digital Compass DOWN/ALTI (Key) • Hour, Minute, Second, Month, Date and Week display ( From 2000 to 2099) • Dual Time Display • Double Alarms • Stopwatch ( Measuring Capacity 99:59:59) • Countdown (Measuring Capacity 99:59:59) • Pedometer Mode • Pace Counter • 12/24 Hour Display • LCD Contrast Setting • EL Backlight (3s display) III. PEDOMETER • Press E Key to cycle through pedometer data (STEP/CALORIE/DISTANCE/SPORT TIME) • Long press the C Key to start and stop the pedometer. • Long press the B Key to enter pedometer settings (Unit of Measure/Footstep/ Weight/) VII. Countdown • You will be able to countdown from 99:59:59 • It will ring 30s when the countdown time is 00:00:00 Setting the Countdown • Long press the B Key for 3s to enter Countdown Mode. • Press the B Key again to enter setting mode. • Press E Key to increase the countdown time. • Press C Key to decrease the countdown time. • Long Press B Key for 3s to Confirm your countdown setting. Using the Countdown • Use the E Key to start/pause and restart your countdown. • To restart your current countdown simply press the E Key to pause and then C Key to return the countdown to its original data. IX. Dual Time • You can run two separate times. T1 and T2. • In T2 mode long press the B Key for 3s and the second will begin flashing. • E Key will increase second and D Key will decrease seconds. • By pressing the B key again, the hours will begin flashing. • Use the same keys to increase or decrease. • Long press the B Key again to leave T2 setting mode X. Monitoring Weather, Temperature and Barometer • In Metronome Mode press C Key to turn on/off the Press the E Key to enter Barometer Mode. It is called BARO Mode. Press E Key in the mode of Barometer, Temperature and Weather Forecast Mode. The measurements will be displayed as follows VIII. Pacer Metronome EXAMPLE OF METRICS • In Metronome Mode press C Key to turn • In this mode you can enter barometer and on/off the metronome. temperature manual calibration mode by long • Long press the C Key for 2s to return to zero pressing B Key for 3s. when the mode is paused. • The calibration items show as below: • The metronome will reset, if its not stopped, AIRP TEMP F.DEF when the counter reaches 99999. • In Temperature mode press the E Key to • In the metronome mode long press, the B Key increase and C Key to decrease temperature. for 2s to enter the beat frequency setting. • To modify pressure, enter the Mode of Input • Press the E Key to increase your setting data. Present Pressure Data. • Press the C Key to decrease your setting data. • Use the E Key to increase pressure and C • Long press the B Key to exit setting mode Key to decrease. • Long press B Key for 3s to confirm and back to standard measurement mode. 5 6 Any issues? Reach out! [email protected] www.BoltWatches.com/Pages/Support-Center Bolt Smartwatch Model: Electron
advertisement
Related manuals
advertisement