Albeo AHH Series Heavy Industrial High Bay Lighting is designed for use in a variety of industrial settings. The luminaire is constructed for durability and features a heavy-duty construction to withstand harsh environments. The AHH Series provides high lumen output, making it ideal for use in warehouses, factories, and other applications where high light levels are required. The luminaire is also designed for energy efficiency, reducing your energy consumption and saving you money on operating costs.
advertisement
▼
Scroll to page 2
of
3
Albeo® AHH Series Installation Guide ALB082 Albeo® AHH2 LED Luminaire Heavy Industrial Bay Lighting ALB082 BEFORE YOU BEGIN Read these instructions completely and carefully. Save these instructions for future use. WARNING/ADVERTISSEMENT/ADVERTENCIA RISK OF ELECTRIC SHOCK Turn power off before inspection, installation or removal. Properly ground electrical enclosure. RISK OF FIRE Follow all NEC and local codes for the required wiring systems for the specific Hazardous Locations involved. RISQUES DE DÉCHARGES ÉLECTRIQUES Coupez l’alimentation avant d’inspecter, installer ou déplacer le luminaire, installer ou déplacer le luminaire. Assurez-vous de correctement mettre à la terre le boîtier d’alimentation électrique. RISQUES D’INCENDIE Respectez tous les codes NEC et codes locaux. This device complies with Part 15 of the FCC Rules, not part of UL Certification. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAN ICES-005 (A) / NMB-005 (A) Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules, not part of UL Certification. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Save These Instructions Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. Prepare Electrical Wiring Electrical Requirements The LED luminaire must be supplied with 120-277 VAC or 347/480 VAC, 50/60 Hz per electrical ratings on product label and connected to an individual properly grounded branch circuit. Grounding Instructions The grounding and bonding of the overall system shall be done in accordance with the national electric code (NEC) Article 600 and local codes. LED.com Page 1 of 3 (Rev 10/05/23) © 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change without notice. All values are design or typical values when measured under laboratory conditions. ALB082-Albeo-AHH-Series-Heavy-Industrial-High-Bay-Lighting-Installation-Guide_R02 Albeo® AHH2 LED Luminaire Installation Guide ALB082 Section 1: Unit Installation Provide at least 12” of clearance from the top of the fixture to any ceiling or surface above. A B Carefully unpack unit and properly inspect for defects before installing. Wear work gloves to prevent dirt and oil from being transferred to the luminaire. C AHH2 is suitable for pendant mount only. Max. Weight (lbs.) AHH2-Series Configuration 120-277V 347/480V Single 21 23 Dual 45 49 Luminaire Input Power Dimming Circuit Black Live White Neutral Green Safety Ground Purple 0-10V (+) Pink 0-10V (-) NOTE: For applications requiring the “R” corrosion resistant finish, use mounting hardware appropriate for the environment. Section 2: Pendant Mounting Attach pendant mount cover to ¾” NPT conduit with at least 3 full threads of engagement. Determine rotation of luminaire and lock orientation in place with provided set screw. Lift luminaire up and hang on pendant mount cover using hinge piece. Feed the AC power lead wire through the conduit and into the junction box. Pink Swing luminaire closed ensuring power lead wires are not pinched and are fully enclosed in pendant mount cover. Secure with the slide clip and lock in place with screw. LED.com Connect the green (ground), black (line) and white (neutral) wires of the AC line to the similarly colored wires of the luminaire’s lead wire using UL listed wire connectors. Close junction box. For dimming options, connect purple and pink leads to dimming control that is certified and suitable for the hazardous locations involved, rated 0-10V min. A 10V signal corresponds to 100% lumen output. A 0V signal corresponds to ~10% lumen output. Cap purple and pink leads separately when not used. Page 2 of 3 (Rev 10/05/23) © 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change without notice. All values are design or typical values when measured under laboratory conditions. ALB082-Albeo-AHH-Series-Heavy-Industrial-High-Bay-Lighting-Installation-Guide_R02 Albeo® AHH2 LED Luminaire Installation Guide ALB082 Secure pendant mount cover to luminaire by fully tightening the captive screws on the sides of the pendant mount box to the fixture. NOTE: Safety chains (installer provided) can be used in mounting slots at end of fixture. Section 3: Trouble Shooting Symptom Solution Luminaire will not turn on • Check that the color of the supply side wires match the color of the wires they are connected to. • Check that all wire connectors are properly connected. • Verify that your input voltage is within specs. • If you are using any additional controls (i.e. dimming wires, motion sensors), please also verify that those are working properly and that the unit is setup to interface with the controllers. Section 4: Maintenance • Product should not be disassembled during installation process and/or while installed. • Lens should be cleaned periodically for maximum lumen output. • Inspect and clear any build-up on cooling fins periodically for maximum performance. Questions: Web: LED.com Phone: 1-866-855-8629 These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to be met in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, the matter should be referred to Current. Ces instructions ne prétendent pas couvrir tous les détails ou variantes de l’équipement ni couvrir toutes les conditions possibles à satisfaire en rapport avec l’installation, l’opération ou l’entretien. Si des informations supplémentaires sont souhaitées sur des aspects qui ne sont pas suffisamment couverts pour satisfaire les besoins du client, ou sides problèmes particuliers se présentent, veuillez addresser ces questions à Current. Estas instrucciones no pretenden cubrir todos los detalles o variaciones en el equipo ni para prever cualquier contingencia que debe cumplir en relación con la instalación, la operación o el mantenimiento. De ser deseada más información o se surgieran problemas particulares que no están cubiertos suficientemente para los propósitos del comprador, favor de remitirse a Current. LED.com Page 3 of 3 (Rev 10/05/23) © 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change without notice. All values are design or typical values when measured under laboratory conditions. ALB082-Albeo-AHH-Series-Heavy-Industrial-High-Bay-Lighting-Installation-Guide_R02
advertisement
Key Features
- Heavy-duty construction
- High lumen output
- Energy efficient
- Pendant mount
- Dimming options
- Corrosion resistant finish
Related manuals
Frequently Answers and Questions
How do I install the Albeo AHH Series luminaire?
The luminaire is designed for pendant mount only. You will need to attach the pendant mount cover to a ¾” NPT conduit and then hang the luminaire on the cover. You will then need to connect the AC power lead wire to the junction box and secure the luminaire in place with the slide clip and lock.
What are the dimming options for the Albeo AHH Series luminaire?
The luminaire can be dimmed using a 0-10V dimming control. A 10V signal corresponds to 100% lumen output. A 0V signal corresponds to ~10% lumen output.
What are the electrical requirements for the Albeo AHH Series luminaire?
The luminaire must be supplied with 120-277 VAC or 347/480 VAC, 50/60 Hz per electrical ratings on product label and connected to an individual properly grounded branch circuit.