advertisement
Gigabit Ethernet Network
Adapters
AT-2916SX
AT-2916LX10/LC-901
AT-2931SX
AT-2972SX
AT-2972LX10/LC-901
AT-2972SX/2
AT-2972T/2
Installation Guide
613-001286 Rev. A
Copyright
2010 Allied Telesis, Inc.
All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc.
Microsoft and Internet Explorer are registered trademarks of Microsoft Corporation. Netscape Navigator is a registered trademark of
Netscape Communications Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners.
Allied Telesis, Inc. reserves the right to make changes in specifications and other information contained in this document without prior written notice. The information provided herein is subject to change without notice. In no event shall Allied Telesis, Inc. be liable for any incidental, special, indirect, or consequential damages whatsoever, including but not limited to lost profits, arising out of or related to this manual or the information contained herein, even if Allied Telesis, Inc. has been advised of, known, or should have known, the possibility of such damages.
Electrical Safety and Emissions Standards
This product meets the following standards.
Federal Communications Commission Interference Statement
Declaration of Conformity
Manufacturer Name: Allied Telesis, Inc.
Declares that the product: Gigabit Ethernet Adapters
Model Numbers: AT-2916SX, AT-2916LX10/LC-901, AT-2931SX, AT-2972SX, AT-2972LX10/LC-901, AT-2972SX/2,
AT-2972T/2
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio or television reception. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device must not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
IMPORTANT NOTE:
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
IEEE802.11b or 802.11g operation of this product in the U.S.A. is firmware-limited to channels 1 through 11.
Industry Canada
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
European Union Restriction of the Use of Certain Hazardous Substances
(RoHS) in Electrical and Electronic Equipment
This Allied Telesis RoHS-compliant product conforms to the European Union Restriction of the Use of Certain Hazardous
Substances (RoHS) in Electrical and Electronic Equipment. Allied Telesis ensures RoHS conformance by requiring supplier Declarations of Conformity, monitoring incoming materials, and maintaining manufacturing process controls.
3
4
RFI Emissions
Immunity
Electrical Safety
Laser Safety
FCC Class B, EN55022 Class B, VCCI Class B, C-TICK, CE
EN55024
EN60950 (TUV), UL 60950 (
C
UL
US
)
EN60825
Translated Safety Statements
Important: The indicates that a translation of the safety statement is available in a PDF document titled “Translated Safety Statements” on the Allied Telesis website at
www.alliedtelesis.com/support/software.
Contents
5
Contents
6
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
7
Contents
8
Figures
9
Figures
10
Preface
This guide contains instructions on how to install the AT-29xx Series
Gigabit Ethernet Network adapters. In addition, procedures are provided that describe how to install and configure the driver software.
The Preface contains the following sections:
“Safety Symbols Used in this Document” on page 12
“Where to Find Web-based Guides” on page 13
“Contacting Allied Telesis” on page 14
11
Preface
Safety Symbols Used in this Document
This document uses the safety symbols defined in Table 1.
Table 1. Safety Symbols
Symbol Meaning
Caution
Description
Performing or omitting a specific action may result in equipment damage or loss of data.
Warning Performing or omitting a specific action may result in electrical shock.
12
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
Where to Find Web-based Guides
The installation and user guides for all Allied Telesis products are available in portable document format (PDF) on our web site at
www.alliedtelesis.com/support/software. You can view the documents online or download them onto a local workstation or server.
13
Preface
Contacting Allied Telesis
This section provides Allied Telesis contact information for technical support as well as sales and corporate information.
Online Support
You can request technical support online by accessing the Allied Telesis
Knowledge Base: www.alliedtelesis.com/support/kb.aspx. You can use the Knowledge Base to submit questions to our technical support staff and review answers to previously asked questions.
Email and
Telephone
Support
For Technical Support via email or telephone, refer to the Support &
Services section of the Allied Telesis web site: www.alliedtelesis.com.
Select your country from the list displayed on the website. then select the appropriate menu tab.
Warranty
For hardware warranty information, refer to the Allied Telesis web site:
www.alliedtelesis.com/support/warranty.
Returning
Products
Products for return or repair must first be assigned a return materials authorization (RMA) number. A product sent to Allied Telesis without an
RMA number will be returned to the sender at the sender’s expense.
To obtain an RMA number, contact the Allied Telesis Technical Support group at our web site: www.alliedtelesis.com/support/rma. Select your country from the list displayed on the website. Then select the appropriate menu tab.
Sales or
Corporate
Information
Management
Software Updates
You can contact Allied Telesis for sales or corporate information through our web site: www.alliedtelesis.com. To find the contact information for your country, select Contact Us -> Worldwide Contacts.
New releases of management software for our managed products are available from either of the following Internet sites:
Allied Telesis web site: www.alliedtelesis.com/support/software
Allied Telesis FTP server: ftp://ftp.alliedtelesis.com
If you prefer to download new software from the Allied Telesis FTP server from your workstation’s command prompt, you will need FTP client software and you must log in to the server. Enter “anonymous” for the user name and your email address for the password.
14
Chapter 1
Introduction to the AT-29xx Series
Gigabit Ethernet Network Adapters
This chapter provides an introduction to the Allied Telesis AT-29xx Series
Gigabit Ethernet Network adapters and contains the following sections:
“Functional Description” on page 16
“AT-29xx Series Adapter Software Drivers” on page 19
15
Chapter 1: Introduction to the AT-29xx Series Gigabit Ethernet Network Adapters
Functional Description
The AT-29xx Series Gigabit Ethernet Network adapters target the increased congestion experienced at the backbone and server in today’s networks. These adapters provide a future upgrade path for high-end workstations that require more bandwidth than Fast Ethernet can provide.
The adapter connects a PCI compliant server or workstation to a Gigabit
Ethernet network. The adapter incorporates a technology that transfers data at a maximum rate of 2Gbps—20 times the rate of Fast Ethernet adapters. In addition, the adapters use fiber optic cabling and a connector that meets 62.5/125um or 50/125um multimode specifications. These adapters operate at 1000 Mbps full-duplex mode only.
The AT-29xxSX Series of Gigabit Ethernet adapters includes the following models:
AT-2916SX
AT-2931SX
AT-2972SX
AT-2972SX/2
The AT-2916 adapter is a 33/66Mhz 32-bit interface (PCI) card and is available in three versions:
AT-2916SX/SC adapter
AT-2916SX/LC adapter
AT-2916LX10/LC-901 adapter (suitable for long-haul fiber optic cables)
The AT-2931SX adapter is a 33/66/133Mhz 32/64-bit interface (PCI-X) card and is available in two versions:
AT-2931SX/SC adapter
AT-2931SX/LC adapter
The AT-2972SX/2, and AT-2972T/2 adapters are both PCI Express 4channel devices. The AT-2972SX is a PCI Express 1-channel device.
The AT-2972LX10/LC-901 adapter is suitable for long-haul fiber optic cables. The AT-2972SX has one port and the AT-2972SX/2 has two ports.
All ports have LC connectors. The AT-2972T/2 has two gigabit copper ports.
16
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
Contents of Your
Shipment
The adapter versions differ only in their PCI connector type. The SC version adapters have an SC connector, and the LC version adapters have an LC connector. The LEDs and software drivers are identical for all adapter models and versions.
Included with your adapter are the following items:
Antistatic bag (used for protecting the adapter when stored or shipped). Keep the adapter in its packaging until ready for installation.
Low-profile bracket
Inform your network supplier of any missing or damaged items. If you need to return the adapter, you must pack it in the original (or equivalent)
packing material or the warranty will be voided. See “Returning Products” on page 14.
17
Chapter 1: Introduction to the AT-29xx Series Gigabit Ethernet Network Adapters
LEDs
All fiber adapter models have two LEDs: LINK and ACT. The LINK LED indicates an active link and the ACT (Activity) LED indicates data transfer status. After the driver is loaded and the cables are connected properly.
The LINK LED is lit and the ACT LED is on if data traffic is present. See
Table 1.
Table 1. Fiber Optic Port LED Status
LED
LINK
ACT
Off
State
On
Off
Blinking
Description
Valid fiber link.
No fiber link.
Data traffic is present between the adapter and the switch.
Data traffic is not present.
The AT-2972T/2 has one copper port with a single LED. For a description, see Table 2.
Table 2. AT-2972T/2 LED
State
On
Off
Blinking
Valid link.
Description
No valid link.
Data traffic is present between the adapter and the switch.
18
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
AT-29xx Series Adapter Software Drivers
Supported
Operating
Systems
Software Driver
Features
An AT-29xx Series adapter is shipped from the factory with the default
Broadcom software driver installed. To update the software driver, you have two options:
If your system has an Internet connection, you can download the AT-
29xx software driver from the Microsoft’s Update Manager. This utility is accessed through the Start button. However, the Microsoft Update
Manager may not have the latest Allied Telesis software drivers.
You can download the latest version of the software driver from the
Allied Telesis website at www.alliedtelesis.com/support/software.
This manual provides instructions to download the software driver from the
Allied Telesis website and install it on your adapter.
The AT-29xx Series Adapters support software drivers on the following operating systems:
Windows Server 2003
Windows XP
Windows 2008 R2
Windows Vista
Windows 7
Linux
Novell NetWare
MS-DOS
The following is a list of the AT-29xx Series Gigabit Ethernet Network adapters features for all of the supported operating systems:
Flow Control (IEEE 802.3X)
Jumbo frames (9 KB)
Layer 2 Priority Encoding (802.1P)
Adaptive interrupt frequency
Integrated 96 KB Frame Buffer Memory
Support for PXE
Load balancing
Note
Novell NetWare 5.1 does not support Jumbo Frames.
19
Chapter 1: Introduction to the AT-29xx Series Gigabit Ethernet Network Adapters
Failover Teaming
Failover Teaming provides redundant adapter operation in the event that a network connection fails. When multiple Allied Telesis Gigabit Ethernet adapters are installed in the same server, they can be paired into Teams.
Each team must have at least one adapter, but can support up to eight adapters. The number of teams is limited by the number of adapters that are installed.
If the primary adapter in a team is disconnected because of failure of the adapter, cable, or switch port, the secondary team member becomes active, redirecting both inbound and outbound traffic originally assigned to the primary adapter. Sessions are maintained, causing no impact to the user.
The AT-29xx Series adapters have advanced server features for teaming and failover. For more information, see the Broadcom Advanced Control
Suite 3 User’s Guide which you can download from the Allied Telesis website at www.alliedtelesis.com/support/software.
Note
Allied Telesis recommends disabling STP when using the teaming and fault tolerance features.
Note
Failover Teaming is available with the Broadcom Advanced Control
Suite 3 (BACS 3) utility.
20
Chapter 2
Installing the Hardware
The AT-29xx Series adapters can be installed in a server or a workstation.
This chapter describes how to install the adapters.
This chapter contains the following sections:
“Reviewing Safety Precautions” on page 22
“Pre-Installation Checklist” on page 24
“Installing a Network Adapter Card” on page 25
“Connecting the Network Cables” on page 29
“Warranty Registration” on page 30
21
Chapter 2: Installing the Hardware
Reviewing Safety Precautions
Please review the following safety precautions before you begin to install the network adapter card.
Note
The indicates that a translation of the safety statement is available in a PDF document titled “Translated Safety Statements” on the Allied Telesis website at www.alliedtelesis.com/support/
software.
Warning
This is a “Class 1 LED product”. L1
Warning
Do not stare into the laser beam. L2
Warning
Warning: Do not look directly at the fiber optic cable ends or inspect the cable ends with an optical lens. E29
Warning
Do not work on this equipment or cables during periods of lightning activity. E2
Warning
Operating Temperature: This product is designed for a maximum ambient temperature of 40 degrees C. E7
Note
All Countries: Install this product in accordance with local and
National Electric Codes. E8
22
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
Warning
The adapter is being installed in a system that operates with voltages that can be lethal. Before you remove the cover of your system, you must observe the following precautions to protect yourself and to prevent damage to the system components.
- Remove any metallic objects or jewelry from your hands and wrists.
- Use only insulated or nonconducting tools.
- Verify that the system is powered OFF and unplugged before accessing internal components.
- Installation or removal of adapters must be performed in a staticfree environment. The use of a properly grounded wrist strap or other personal antistatic devices and an antistatic mat is strongly recommended. E39
23
Chapter 2: Installing the Hardware
Pre-Installation Checklist
1. Check that your system has an appropriate open PCI slot.
2. Verify that your system is using the latest BIOS.
3. If your system is active, shut it down.
4. When system shut down is complete, power OFF and unplug your system.
5. Holding the adapter card by the edges, remove it from its shipping package and place it on an antistatic surface.
6. Check the adapter for visible signs of damage, particularly on the card’s edge connector.
Never attempt to install any damaged adapter. If the adapter is
damaged, report it to Allied Telesis. See “Contacting Allied Telesis” on page 14.
24
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
Installing a Network Adapter Card
The following instructions apply to installing an AT-29xx Series Gigabit
Ethernet Network adapter in most systems. Refer to the manuals that were supplied with your system for details about performing these tasks on your particular system.
To install the network adapter card, perform the following procedure:
1. Review the “Pre-Installation Checklist” on page 24 and “Reviewing
Safety Precautions” on page 22.
Before installing the adapter, ensure the system power is OFF and unplugged from the power outlet, and that proper electrical grounding procedures have been followed.
Warning
High voltage inside the system presents a safety hazard. Make sure the power is off before removing the cover.
2. Remove the system cover and select any appropriate empty PCI slot.
If you do not know how to identify an appropriate PCI slot, refer to your system documentation.
Figure 1. Removing the PC Cover
25
Chapter 2: Installing the Hardware
3. Select an empty, non-shared PCI slot and remove the faceplate.
Keep the faceplate in a safe place. You may need it for future use. See
Figure 2. Removing the Faceplate From PCI Slot
Note
If you cannot locate or know how to find an appropriate PCI slot, refer to the documentation that came with your system.
4. Remove the network adapter card from the shipping package and store the packaging material in a safe location.
Caution
Wear a grounding device and observe electrostatic discharge precautions when installing the network adapter card in a system.
Failure to observe this caution could result in damage to the card.
5. Applying even pressure at both corners of the card, push the adapter card until it is firmly seated in the appropriate PCI slot.
26
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
Make sure the card is securely seated. See Figure 3.
Figure 3. Inserting the Network Adapter Card
Note
The connector dock in a 32-bit PCI slot is shorter than in a 64-bit PCI slot. Although the AT-2931SX adapter is designed to fit in either slot type, when installed in a 32-bit PCI slot, part of the adapter’s connector edge remains undocked. This is part of normal operation.
Note
When you install an AT-2931SX adapter in a 32-bit slot, the adapter operates in 32-bit mode only.
Caution
Do not use excessive force when seating the card, because this may damage the system or the adapter. If the card resists seating, remove it from the system, realign it, and try again.
27
Chapter 2: Installing the Hardware
6. Secure the network adapter card to the chassis with a Phillips-head
screw (not provided) as shown in Figure 4.
Figure 4. Securing the Adapter Card
7. Replace the system’s cover and secure it with the screws removed in
8. Disconnect any personal antistatic devices.
9. Power the system on.
Note
If you installed the adapter card in a Microsoft Windows Operating system before installing the driver software, the Found New
Hardware Wizard launches automatically. For more information, refer to the chapter for your Windows Operating system.
Once the system returns to proper operation, the adapter hardware is fully
installed. Next, connect the network cables. See “Connecting the Network
28
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
Connecting the Network Cables
All the fiber Gigabit Ethernet network adapters have two fiber optic connectors for attaching the system to a compatible link partner, or an
IEEE 802.3z compliant gigabit switch. After connecting the system to the network and power is supplied, the adapter performs auto-negotiation and attempts to establish the connection at 1000 Mbps full-duplex only.
To connect a network cable to the adapter, perform the following procedure:
1. Prepare a fiber optic cable according to the specifications in Table 3.
Table 3. 1000BASE-SX Fiber Optic Cable Specifications
Port Type
1000BASE-SX
1000BASE-SX
1000BASE-LX
Connector
Fiber Optic
Fiber Optic
Fiber Optic
50 µm multimode
850 nm
62.5 µm multimode
850 nm
9.125 µm single mode
1310 nm
Media
Maximum
Distance
550 meters
(1,804 feet)
275 meters
(853 feet)
10 kilometer
(6.213 miles)
Warning
The fiber optic ports contain a Class 1 laser device. When the ports are disconnected, always cover them with the provided plug.
Exposed ports may cause skin or eye damage
.
2. Connect one end of the cable to the adapter.
3. Connect the other end of the cable to the appropriate Ethernet network port or fiber optic port.
Note
After the cable is properly connected at both ends, the adapter port
LEDs should be functional. See Table 1 on page 18 for a description of adapter port LED operation. For driver installation and configuration instructions, refer to the software configuration for a specific driver.
The AT-2972T/2 has two copper connectors for attaching the system to a compatible link partner. After you connect to the network and power is supplied, the adapter performs auto-negotiation and attempts to establish the connection at the appropriate speed and duplex mode.
29
Chapter 2: Installing the Hardware
Warranty Registration
Allied Telesis hardware products are covered under limited warranties.
Some products have a longer coverage than others.
All Allied Telesis warranties are subject to and provided only on the terms and conditions set out in the Allied Telesis Limited Warranties listed on the
Allied Telesis website at http://alliedtelesis.com/support/warranty.
30
Chapter 3
Installing Windows Server 2003 and
Windows XP Driver Software
This chapter describes how to install the Windows Server 2003 and
Windows XP driver software. This chapter contains the following sections:
“Installing the Driver Software” on page 32
“Uninstalling the Driver Software” on page 41
After you install the driver software, you can modify the configuration
properties as described in see Chapter 5, “Setting Advanced Properties” on page 53.
31
Chapter 3: Installing Windows Server 2003 and Windows XP Driver Software
Installing the Driver Software
When a Windows Server 2003 or Windows XP system first boots up after installing a new Allied Telesis Gigabit Ethernet adapter, the system automatically detects the new hardware and prompts you to install the driver software for that device.
There are three installation procedures:
“Using the Driver Installer” on page 32
“Updating the Adapter Software” on page 35
“Modifying Configuration Properties” on page 39
Note
The adapter must be physically installed in your system before installing the driver software. See Chapter 2, “Installing the
Hardware” on page 21 for details.
Note
If the Windows Server 2003 or Windows XP system detects an adapter and installs a default driver, update the driver as described
in “Updating the Adapter Software” on page 35.
Note
If there is an onboard Broadcom network interface, the native
Broadcom driver may load. You can use this driver, or the latest driver supplied by Allied Telesis.
Using the Driver
Installer
When you boot up either operating system after installing the adapter card, a series of Found New Hardware windows are displayed. You must have Administrator privileges to install the driver software.
Note
Before beginning this procedure, verify that the Windows Server
2003 or Windows XP system has been upgraded to the latest version with the latest service pack applied.
Note
If you have a Windows XP system, the window in Figure 5 on page
33 opens. Start with step 1. If you have a Windows Server 2003
system, the window in Figure 6 on page 34 opens. Start with step 3
on the same page.
32
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
To install the adapter software on a Windows Server 2003 or Windows XP system, do the following:
1. Click Install from a list or specific location (Advanced).
Figure 5. Welcome to the Found New Hardware Wizard Window
2. Click Next.
The second Welcome to the Found New Hardware Wizard Window is
33
Chapter 3: Installing Windows Server 2003 and Windows XP Driver Software
Figure 6. Found New Hardware Wizard Window: Search and Installation
Options
3. Click Include this location in the search.
4. Click Browse and locate the path of the software driver.
5. Click Next.
6. When the software installation is complete, click Finish to close the wizard and complete the software installation.
34
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
Updating the
Adapter Software
This section provides a procedure for updating the adapter software for the
Windows Server 2003 or Windows XP systems. To obtain the latest version of an AT-29xx Series adapter software drivers, download it from the Allied Telesis website at www.alliedtelesis.com/support/software.
Note
You may need to reboot your system after completing the driver update to properly load the new drivers.
When you update the adapter software on existing devices, the Advanced
Property settings may not be updated unless you remove the existing
manager followed by reinstalling the device with the current adapter
software as described in “Installing the Driver Software” on page 32.
Note
Before uninstalling a device, capture all of the Advanced Property settings because the properties will be lost.
Updating the Windows Server 2003 or Windows XP Driver Software
To update the adapter software on a Windows Server 2003 or a Windows
XP system, perform the following procedure.
Note
Update all adapters by repeating the following steps on each device.
1. Start either a Windows Server 2003 or a Windows XP system and log in.
You must have Administrator privileges to update the driver software.
2. On the desktop, open the Start menu.
See Figure 7 on page 36 for an example of the Start menu.
35
Chapter 3: Installing Windows Server 2003 and Windows XP Driver Software
Figure 7. Windows Server 2003 Start Window
3. Select Run from the menu and enter the following command: devmgmt.msc
See Figure 8 for an example of the Run Window.
Figure 8. Run Window
36
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
The Device Manager Window is shown in Figure 9.
Figure 9. Device Manager Window (Network adapter folder is collapsed)
4. In the Device Manager window, click the + next to the Network adapters folder.
The selection expands to show the list of installed network adapter cards.
5. Right click on the adapter whose driver you want to update and select
Update Driver.
37
Chapter 3: Installing Windows Server 2003 and Windows XP Driver Software
The Hardware Update Wizard Window opens, as shown in Figure 10.
Figure 10. Welcome to Hardware Update Wizard Window
6. For a Windows Server 2003 system, skip to step 10. For a Windows
XP system, click No, not this time to copy the driver software from your PC.
7. Click Next.
The Second New Found Hardware Wizard Window opens, as shown
38
Figure 11. Hardware Update Wizard Window
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
Modifying
Configuration
Properties
8. Click Install from a list or specified location (Advanced).
9. Click Next.
10. If you are prompted to specify the location of the software driver, click
Browse (do not use the text field) and locate the path.
After you install the driver software, you can modify the configuration
properties. See Chapter 5, “Setting Advanced Properties” on page 53.
Although the default values are appropriate in most cases, you can change any of the available options to meet the requirements of your specific system. After the adapter driver software has been installed, you can use this procedure to access the System Property Dialog box which provides access to the Advanced Properties on the Advanced Tab.
To access the System Properties Dialog box, perform the following procedure:
1. Start either a Windows Server 2003 or a Windows XP system and log in.
You must have Administrator privileges to update the driver software.
2. On the desktop, right click My Computer.
The My Computer window opens.
3. Select Properties from the menu.
The System Properties Dialog box opens, as shown in Figure 12 on page 40.
39
Chapter 3: Installing Windows Server 2003 and Windows XP Driver Software
40
Figure 12. System Properties Dialog Box
For instructions that describe how to set the Advanced Properties, see
Chapter 5, “Setting Advanced Properties” on page 53.
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
Uninstalling the Driver Software
Before physically removing an adapter from your system, you must uninstall the adapter driver software.
Caution
Before uninstalling the Allied Telesis device, be sure to capture all
Advanced Property settings because the properties are lost during the uninstall process.
To uninstall the adapter software from your system, perform the following procedure:
1. Start Windows Server 2003 or Windows XP and log in.
Note
You must have Administrator privileges to remove the driver software.
2. Choose from the following:
If you have a Windows Server 2003 Server system, click Start.
Then select the Control Panel from the menu. Double-click the
System icon.
If you have a Windows XP system, right click on My Computer
Then select Properties from the menu.
The Device Manager Window opens. It is shown in Figure 9 on page
3. In the Device Manager window, click the + next to the Network adapters folder.
The selection expands to show the list of installed network adapter cards.
4. Right-click on the adapter to be removed and select Uninstall.
A Confirm Device Removal window opens.
5. Click OK to complete the uninstall.
Note
Not all driver files are removed as part of this procedure.
41
Chapter 3: Installing Windows Server 2003 and Windows XP Driver Software
42
Chapter 4
Installing the Windows 2008 R2, Windows
Vista, and Windows 7 Driver Software
This chapter describes how to install the Windows 2008 R2, Windows
Vista, and Windows 7 driver software on an AT-29xx Series adapter. The installation procedures are identical for both the 32-bit and 64-bit Windows
Operating Systems.
This chapter contains the following sections:
“Installing the Driver Software” on page 44
“Uninstalling the Driver Software” on page 51
Note
To set Advanced Properties, see Chapter 5, “Setting Advanced
43
Chapter 4: Installing the Windows 2008 R2, Windows Vista, and Windows 7 Driver Software
Installing the Driver Software
Selecting the
Device Manager
After you install an AT-29xx Series adapter, the system detects the new hardware and creates an entry in the Device Manager when the Windows operating system first boots up. Shortly after you log in, you need to install the driver software for the AT-29xx Series adapter. To install or update the driver software, you must have administrative privileges.
This section provides the following procedures:
“Selecting the Device Manager” on page 44
“Installing the Windows 2008 R2, Windows, Vista, and Windows 7
You must access the Device Manager during the both the install and uninstall procedures. Each operating system has its own method of selecting the Device Manager. See the following procedures:
“Selecting the Device Manager in Windows 2008 R2 and Windows 7” on page 44
“Selecting the Device Manager in Windows Vista” on page 46
Selecting the Device Manager in Windows 2008 R2 and Windows 7
To select the Device Manager in Windows 2008 R2 or Windows 7, do the following:
1. Select the Start button. See Figure 13 on page 45.
44
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
Figure 13. Windows 2008 R2 and Windows 7 Search Box
2. Enter the following command: mmc compmgmt.msc
The Device Manager window is displayed. For an example of the
Device Manager window, see Figure 9 on page 37.
45
Chapter 4: Installing the Windows 2008 R2, Windows Vista, and Windows 7 Driver Software
Selecting the Device Manager in Windows Vista
To select the Device Manager in the Windows Vista Operating System, do the following:
1. Select the Start menu.
See Figure 14 for an example of the Windows Vista Start menu.
46
Figure 14. Windows Vista Start Menu
2. From the Start Menu, select Run.
The Windows Vista Run window is displayed. See Figure 15.
Figure 15. Windows Vista Run Window
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
3. Enter the following command in the Run window: mmc devmgmt.msc
4. From the Computer Management Window, select Device Manager in
the left panel. The Device Manager window is displayed. See Figure
On the Device Manager window, “Allied Telesis AT-2972SX Gbps
Fiber Ethernet” is listed under “Network adapters.”
The Device Manager window for an AT-2972SX adapter is shown in
Figure 16. Device Manager Window
47
Chapter 4: Installing the Windows 2008 R2, Windows Vista, and Windows 7 Driver Software
Installing the
Windows 2008
R2, Windows,
Vista, and
Windows 7
Driver Software
To obtain the latest version of an AT-29xx Series adapter software drivers, download it from the Allied Telesis website at www.alliedtelesis.com/
support/software.
To install the Windows 2008 R2, Windows Vista, or Windows 7 Operating
System driver software, do the following:
Note
The adapter must be physically installed in your system before you install the driver software. See Chapter 2, “Installing the Hardware” on page 21 for instructions.
1. Start a Windows operating system and log in.
2. Open the Device Manager.
For instructions on how to open the Device Manager, see one of the following procedures:
– “Selecting the Device Manager in Windows 2008
– “Selecting the Device Manager in Windows Vista” on page 46
3. In the Device Manager window, click the + next to the Network adapters folder.
The selection expands to show the list of installed network adapter cards installed on your PC. An AT-29xx Series adapter is listed either by its Allied Telesis name or “Broadcom NetExtreme.”
4. Right click Ethernet Controller and select Update Driver Software.
See Figure 17 for an example of the Device Manger window with
Ethernet Controller selected.
Figure 17. Device Manager Window: Ethernet Controller
48
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
The Update Driver Software - Ethernet Controller Window is displayed.
Figure 18. Update Driver Software - Ethernet Controller Window
5. Click Browse my computer for driver software.
The Update Driver Software - Ethernet Controller: Browse for Driver
Software Window is displayed. See Figure 20 on page 50.
49
Chapter 4: Installing the Windows 2008 R2, Windows Vista, and Windows 7 Driver Software
6. Click Browse to search your computer for the location of the driver
Figure 19. Update Driver Software: Ethernet Controller: Browse
7. Click Next. A confirmation message is displayed. See Figure 20.
50
Figure 20. Update Driver Software - Confirmation Window
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
Uninstalling the Driver Software
Before physically removing an adapter from your system, you need to uninstall the driver software first. The procedure in this section describes how to uninstall the driver software.
Note
You must have Administrator privileges to remove the driver software.
Caution
Before uninstalling the Allied Telesis device, be sure to capture all of the Advanced Property settings because the properties are lost during the uninstall process.
To uninstall the driver software from your system, do the following:
1. Start a Windows 2008 R2, Windows Vista, or Windows 7 Operating
System on your laptop and log in.
2. Open the Device Manager.
For instructions on how to open the Device Manager, see the following:
– “Selecting the Device Manager in Windows 2008
– “Selecting the Device Manager in Windows Vista” on page 46
The Device Manager Window is shown in Figure 16 on page 47.
3. In the Device Manager window, click the + next to the Network adapters folder.
The selection expands to show the list of installed network adapter cards.
4. Right-click on the adapter you want to remove and select Uninstall.
A Confirm Device Removal window opens.
5. Click OK to complete the uninstall.
51
Chapter 4: Installing the Windows 2008 R2, Windows Vista, and Windows 7 Driver Software
Note
Not all of the driver files are removed as a result of this procedure.
You can remove additional drivers and installation files by selecting the checkbox to remove these files.
52
Chapter 5
Setting Advanced Properties
The Windows Advanced Properties are accessible from the Advanced
Tab. For Windows Server 2003 and Windows XP systems, you access the
Advanced Tab through the System Properties Dialog Box. For the
Windows 2008 R2, Windows Vista, and Windows 7 Operating System software, you access the Advanced Tab through the Device Manager.
This chapter contains the following section:
“Opening Advanced Properties” on page 54
53
Chapter 5: Setting Advanced Properties
Opening Advanced Properties
In most cases, the default property values available on the Advanced Tab are appropriate although you can change any of the available options to meet the requirements of your system. You must have Administrator privileges to modify the driver software. After the driver software has been installed, you can use the following procedures to verify or change the adapter properties:
“Ethernet@Wirespeed™ (AT-2972/T2 only)” on page 57
“Interrupt Moderation” on page 59
“Large Send Offload Property” on page 61
“Receive Side Scaling” on page 64
“Speed & Duplex Mode” on page 65
“Wake Up Capabilities” on page 68
Note
After you upgrade the driver software, the Advanced Properties may change.
Note
The procedures in the sections listed above may differ slightly if the
“Classic Start Menu” is set on your computer.
54
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
802.1p QOS
The 802.1p QOS property is a standard that enables Quality of Service
(QOS). It is responsible for the QOS provisions on the local segment, and the avoidance of the “all packets are treated equally” issue, which falls onto the hub or switch servicing segment. The 802.1p QOS property provides prioritization of packets traversing a subnet. Thus, when the local segment becomes congested and the hub or switch workload results in the delay (dropping) of packets, those packets with flags that correspond to higher priorities receive preferential treatment and are serviced before packets with lower priorities.
To enable or disable the 802.1p QOS property, perform the following procedure:
1. For Windows Server 2003 and Windows XP systems, access the
System Properties Dialog Box. See “Modifying Configuration
Properties” on page 39.
For Windows 2008 R2, Windows 7, and Windows Vista systems, access the Device Manger for your operating system:
To access the Device Manager window in Windows 2008 R2 or
Windows 7, see “Selecting the Device Manager in Windows 2008
To access the Windows Vista Device Manager, see “Selecting the
Device Manager in Windows Vista” on page 46.
2. Click the Advanced tab.
The Advanced tab is shown in Figure 21 on page 56.
55
Chapter 5: Setting Advanced Properties
56
Figure 21. Advanced Tab
3. From the Properties list, select 802.1p QOS.
4. From the Values list, select one of the following:
Enable - Enables the 802.1p QOS property.
Disable - Disables the 802.1p QOS property. This is the default.
Note
Enabling 802.1p QOS requires an 802.1p-aware switch.
5. Click OK.
6. If prompted to restart your computer, click Yes.
Although it is not necessary to reboot the system for new adapter properties to take effect, rebooting is recommended to reinitialize all registers.
7. Verify that the adapter port LEDs operate as described in “LEDs” on page 18.
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
Ethernet@Wirespeed
™
(AT-2972/T2 only)
The Ethernet@Wirespeed property enables a Gigabit Ethernet adapter to establish a link at a lower speed when only two pairs of wires are available in the cabling plant. This property is available on the AT-2972/T2 adapter only. By default, the Ethernet@Wirespeed property is enabled.
To change the Ethernet@Wirespeed property, perform the following procedure:
1. For Windows Server 2003 and Windows XP systems, access the
System Properties Dialog Box. See “Modifying Configuration
Properties” on page 39.
For Windows 2008 R2, Windows 7, and Windows Vista systems, access the Device Manger for your operating system:
To access the Device Manager window in Windows 2008 R2 or
Windows 7, see “Selecting the Device Manager in Windows 2008
To access the Windows Vista Device Manager, see “Selecting the
Device Manager in Windows Vista” on page 46.
2. Click the Advanced tab.
The Advanced tab is shown in Figure 21 on page 56.
3. From the Properties list, select Ethernet@Wirespeed.
4. From the Values list, select one of the following:
Enable - Enables Ethernet@Wirespeed. This is the default.
Disable - Disables Ethernet@Wirespeed.
5. Click OK.
6. If prompted to restart your computer, click Yes.
Although it is not necessary to reboot the system for new adapter properties to take effect, rebooting is recommended to reinitialize all registers.
7. Verify that the adapter port LEDs operate as described in “LEDs” on page 18.
Flow Control
The Flow Control property allows you to enable or disable the receipt or transmission of PAUSE frames which allow the adapter and the switch to control the transmit rate. The port side that receives the PAUSE frame momentarily stops transmitting. The recommended selection is Disable, which configures the adapter to ignore PAUSE frames. By default, the
Flow Control property is disabled.
57
Chapter 5: Setting Advanced Properties
To change the Flow Control property, do the following:
1. For Windows Server 2003 and Windows XP systems, access the
System Properties Dialog Box. See “Modifying Configuration
Properties” on page 39.
For Windows 2008 R2, Windows 7, and Windows Vista systems, access the Device Manger for your operating system:
To access the Device Manager window in Windows 2008 R2 or
Windows 7, see “Selecting the Device Manager in Windows 2008
To access the Windows Vista Device Manager, see “Selecting the
Device Manager in Windows Vista” on page 46.
2. Click the Advanced tab.
The Advanced tab is shown in Figure 21 on page 56.
3. From the Property list on the Advanced tab, select Flow Control.
4. From the Value list on the Advanced tab, select one of the following:
Auto - (default) PAUSE frame receipt and transmission is optimized.
Disable - PAUSE frame receipt and transmission is disabled
(recommended).
Rx PAUSE - PAUSE frame receipt is enabled.
Rx/Tx PAUSE - PAUSE frame receipt and transmission is enabled.
Tx PAUSE - PAUSE frame transmission is enabled.
5. Click OK.
6. If prompted to restart your computer, click Yes.
Although it is not necessary to reboot the system for new adapter properties to take effect, rebooting is recommended to reinitialize all registers.
7. Verify that the port LED operates as described in “LEDs” on page 18.
Jumbo Mtu
The Jumbo Mtu property allows the adapter to transmit and receive oversized Ethernet frames that are greater than 1,514 bytes but less than
9,000 bytes in length. Note that this property requires a switch that is able to process large frames.
By default, the Jumbo Mtu property is set to 1500 bytes.
58
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
Interrupt
Moderation
To increase the size of the received frames, do the following:
1. For Windows Server 2003 and Windows XP systems, access the
System Properties Dialog Box. See “Modifying Configuration
Properties” on page 39.
For Windows 2008 R2, Windows 7, and Windows Vista systems, access the Device Manger for your operating system:
To access the Device Manager window in Windows 2008 R2 or
Windows 7, see “Selecting the Device Manager in Windows 2008
To access the Windows Vista Device Manager, see “Selecting the
Device Manager in Windows Vista” on page 46.
2. Click the Advanced tab.
The Advanced tab is shown in Figure 21 on page 56.
3. From the Properties list, select Flow Control.
4. From the Values list, increment the byte quantity in 500-byte increments.
5. Click OK.
6. If prompted to restart your computer, click Yes.
Although it is not necessary to reboot the system for new adapter properties to take effect, rebooting is recommended to reinitialize all registers.
7. Verify that the adapter port LEDs operate as described in “LEDs” on page 18.
Interrupt moderation enables adaptive interrupt coalescing, which limits the rate of interrupt to the CPU during packet transmission and packet reception. The disabled option allows one interrupt for every packet transmission and packet reception. The default value is Enabled.
To change the Interrupt Moderation setting, do the following:
1. For Windows Server 2003 and Windows XP systems, access the
System Properties Dialog Box. See “Modifying Configuration
Properties” on page 39.
59
Chapter 5: Setting Advanced Properties
For Windows 2008 R2, Windows 7, and Windows Vista systems, access the Device Manger for your operating system:
To access the Device Manager window in Windows 2008 R2 or
Windows 7, see “Selecting the Device Manager in Windows 2008
To access the Windows Vista Device Manager, see “Selecting the
Device Manager in Windows Vista” on page 46.
2. From the Advanced tab under Property, select Interrupt Moderation.
For an example of the Advanced tab, see Figure 21 on page 56.
3. From the Value list on the Advanced tab, select one of the following:
Enabled
Disabled
4. Click OK.
5. If prompted to restart your computer, click Yes.
Although it is not necessary to reboot the system for new adapter properties to take effect, rebooting is recommended to reinitialize all registers.
6. Verify that the port LED operates as described in “LEDs” on page 18.
IPSec Offload
Traditionally, IPSec has been used for remote connections, but this feature has moved into the Local Area Network (LAN) to secure local network traffic against eavesdropping.
Vista’s Next Generation TCP/IP stack provides APIs for accessing brackets to allow advanced granularity to filter both inbound and outbound traffic.This was not possible with Microsoft’s XP Operating system. In addition, Vista’s security management now closely ties the firewall and
IPSec features together by using a snap-in called Windows Firewall with
Advanced Security. The onboard encryption engine on an AT-29xx Series adapter off-loads this task to the network controller instead of the host
CPU, thereby freeing the host CPU for other important tasks. The offloading feature is unique in the industry and enables you to set tight security efficiently within your network at a minimal cost.
Microsoft’s Technet website, www.technet.microsoft.com, offers several technical publications and online seminars that describe Vista’s advanced
IPSec and Firewall features as well as their implementation. These topics are beyond the scope of this chapter. Instead, Allied Telesis recommends that you consult Technet for additional information.
By default, the IPSec Offload property is set to Disabled.
60
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
Note
The IPSec Offload feature applies only to Windows Vista and
Windows 7.
Large Send
Offload Property
To change the IPSec Offload setting, do the following:
1. For Windows Server 2003 and Windows XP systems, access the
System Properties Dialog Box. See “Modifying Configuration
Properties” on page 39.
For Windows 2008 R2, Windows 7, and Windows Vista systems, access the Device Manger for your operating system:
To access the Device Manager window in Windows 2008 R2 or
Windows 7, see “Selecting the Device Manager in Windows 2008
To access the Windows Vista Device Manager, see “Selecting the
Device Manager in Windows Vista” on page 46.
2. From the Advanced tab under Property, select IPSec Offload.
For an example of the Advanced tab, see Figure 21 on page 56.
3. From the Value list on the Advanced tab, select one of the following:
Auth Header & ESP Enabled
Auth Header Enabled
Disabled
ESP Enabled
4. Click OK.
5. If prompted to restart your computer, click Yes.
Although it is not necessary to reboot the system for new adapter properties to take effect, rebooting is recommended to reinitialize all registers.
6. Verify that the port LED operates as described in “LEDs” on page 18.
Normally, the protocol stack performs TCP segmentation. When you enable the Large Send Offload property, the network adapter does the
TCP segmentation. There are several Large Send Offload properties to choose from, depending on the TCP/IP version you are using on your PC.
You can select IPV4, IPV4 version 2, or IPv6 version 2. By default, the
Large Send Offload Property is disabled.
61
Chapter 5: Setting Advanced Properties
To change the Large Send Offload property, do the following:
1. For Windows Server 2003 and Windows XP systems, access the
System Properties Dialog Box. See “Modifying Configuration
Properties” on page 39.
For Windows 2008 R2, Windows 7, and Windows Vista systems, access the Device Manger for your operating system:
To access the Device Manager window in Windows 2008 R2 or
Windows 7, see “Selecting the Device Manager in Windows 2008
To access the Windows Vista Device Manager, see “Selecting the
Device Manager in Windows Vista” on page 46.
2. Click the Advanced tab.
The Advanced tab is shown in Figure 21 on page 56.
3. From the Property list on the Advanced tab, select one of the following:
Large Send Offload (IPv4)
Large Send Offload v2 (IPv4)
Large Send Offload v2 (IPv6)
4. From the Value list on the Advanced tab, select one of the following:
Enable - Enables the Large Send Offload property.
Disable - Disables the Large Send Offload property. This is the default.
5. Click OK.
6. If prompted to restart your computer, click Yes.
Although it is not necessary to reboot the system for new adapter properties to take effect, rebooting is recommended to reinitialize all registers.
7. Verify that the port LED operates as described in “LEDs” on page 18.
Network Address
The Network Address is a user-defined address that is used to replace the
MAC address that was originally assigned to the adapter. In some operating systems, this property is called Locally Administered Address.
The network address consists of a 12-digit hexadecimal number.
62
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
To change the Network Address property, do the following:
1. For Windows Server 2003 and Windows XP systems, access the
System Properties Dialog Box. See “Modifying Configuration
Properties” on page 39.
For Windows 2008 R2, Windows 7, and Windows Vista systems, access the Device Manger for your operating system:
To access the Device Manager window in Windows 2008 R2 or
Windows 7, see “Selecting the Device Manager in Windows 2008
To access the Windows Vista Device Manager, see “Selecting the
Device Manager in Windows Vista” on page 46.
2. Click the Advanced tab.
The Advanced tab is shown in Figure 21 on page 56.
3. From the Property list on the Advanced tab, select Network Address.
4. In the Value list on the Advanced tab, enter the Locally Administered
Address. Here are some guidelines:
The range is 0000 0000 0001 to FFFF FFFF FFFD.
Do not use a multicast address (least significant bit of the high byte = 1).
Do not use all 0's or all F's.
5. Click OK.
6. If prompted to restart your computer, click Yes.
Although it is not necessary to reboot the system for new adapter properties to take effect, rebooting is recommended to reinitialize all registers.
7. Verify that the port LED operates as described in “LEDs” on page 18.
Priority & VLAN
Priority allows you to prioritize traffic or limit bandwidth instead of treating all traffic in the same manner. A Virtual Local Area Network (VLAN) is a logical area network that extends beyond a traditional LAN to a group of logical LANs.
By default, this property is set to Priority & VLAN Enabled.
To set the port priority and assign a VLAN ID, do the following:
1. For Windows Server 2003 and Windows XP systems, access the
System Properties Dialog Box. See “Modifying Configuration
Properties” on page 39.
63
Chapter 5: Setting Advanced Properties
Receive Side
Scaling
For Windows 2008 R2, Windows 7, and Windows Vista systems, access the Device Manger for your operating system:
To access the Device Manager window in Windows 2008 R2 or
Windows 7, see “Selecting the Device Manager in Windows 2008
To access the Windows Vista Device Manager, see “Selecting the
Device Manager in Windows Vista” on page 46.
2. Click the Advanced tab.
The Advanced tab is shown in Figure 21 on page 56.
3. From the Property list on the Advanced tab, select “Priority & VLAN.”
4. In the Value list on the Advanced tab, select one of the following:
Priority & VLAN Disabled
Priority & VLAN Enabled
Priority Enabled
VLAN Enabled
5. Click OK.
6. If prompted to restart your computer, click Yes.
Although it is not necessary to reboot the system for new adapter properties to take effect, rebooting is recommended to reinitialize all registers.
7. Verify that the port LED operates as described in “LEDs” on page 18.
The Receive Side Scaling (RSS) feature configures RSS queues from 1 to
4. The available options are RSS 1 Queue, RSS 2 Queue, and RSS 4
Queue. By default, RSS is set to Enabled.
To set Receive Side Scaling, do the following:
1. For Windows Server 2003 and Windows XP systems, access the
System Properties Dialog Box. See “Modifying Configuration
Properties” on page 39.
For Windows 2008 R2, Windows 7, and Windows Vista systems, access the Device Manger for your operating system:
To access the Device Manager window in Windows 2008 R2 or
Windows 7, see “Selecting the Device Manager in Windows 2008
To access the Windows Vista Device Manager, see “Selecting the
Device Manager in Windows Vista” on page 46.
64
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
Speed & Duplex
Mode
2. Click the Advanced tab.
The Advanced tab is shown in Figure 21 on page 56.
3. From the Property list on the Advanced tab, select “Receive Side
Scaling.”
4. In the Value list on the Advanced tab, select one of the following:
Enabled
Disabled
5. Click OK.
6. If prompted to restart your computer, click Yes.
Although it is not necessary to reboot the system for new adapter properties to take effect, rebooting is recommended to reinitialize all registers.
7. Verify that the port LED operates as described in “LEDs” on page 18.
The speed and duplex mode property allows you to set the speed of the adapter as well as the change the duplex mode from full to half. By default, the duplex mode is set to a speed of 100 Mb in full duplex mode.
To change the speed and duplex mode of an adapter, do the following:
1. For Windows Server 2003 and Windows XP systems, access the
System Properties Dialog Box. See “Modifying Configuration
Properties” on page 39.
For Windows 2008 R2, Windows 7, and Windows Vista systems, access the Device Manger for your operating system:
To access the Device Manager window in Windows 2008 R2 or
Windows 7, see “Selecting the Device Manager in Windows 2008
To access the Windows Vista Device Manager, see “Selecting the
Device Manager in Windows Vista” on page 46.
2. Click the Advanced tab.
The Advanced tab is shown in Figure 21 on page 56.
3. From the Property list on the Advanced tab, select “Speed & Duplex.”
4. In the Value list on the Advanced tab, select one of the following:
10 Mb Full
10 Mb Half
65
Chapter 5: Setting Advanced Properties
Checksum
Offload
100 Mb Full
100 Mb Half
Auto
5. Click OK.
6. If prompted to restart your computer, click Yes.
Although it is not necessary to reboot the system for new adapter properties to take effect, rebooting is recommended to reinitialize all registers.
7. Verify that the port LED operates as described in “LEDs” on page 18.
Usually, the Checksum Offload function is computed by the protocol stack.
By selecting one of the Checksum Offload properties, the adapter can compute the checksum.
To change the Checksum Offload setting, do the following:
1. For Windows Server 2003 and Windows XP systems, access the
System Properties Dialog Box. See “Modifying Configuration
Properties” on page 39.
For Windows 2008 R2, Windows 7, and Windows Vista systems, access the Device Manger for your operating system:
To access the Device Manager window in Windows 2008 R2 or
Windows 7, see “Selecting the Device Manager in Windows 2008
To access the Windows Vista Device Manager, see “Selecting the
Device Manager in Windows Vista” on page 46.
2. Click the Advanced tab.
The Advanced tab is shown in Figure 21 on page 56.
3. From the Property list under the Advanced tab, select TCP/UDP
Checksum Offload v4, or TCP/UDP Checksum Offload v6.
4. From the Value list on the Advanced tab, select one of the following:
None - Disables checksum offloading.
Rx TCP/IP Checksum - Enables receive TCP, IP, and UDP checksum offloading.
Tx TCP/IP Checksum - Enables transmit TCP, IP, and UDP checksum offloading.
Tx/Rx TCP/IP Checksum (default) - Enables transmit and receive
TCP, IP, and UDP checksum offloading.
66
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
5. Click OK.
6. If prompted to restart your computer, click Yes.
Although it is not necessary to reboot the system for new adapter properties to take effect, rebooting is recommended to reinitialize all registers.
7. Verify that the port LED operates as described in “LEDs” on page 18.
VLAN ID
The VLAN ID specifies the VLAN identifier. It is the number of the VLAN where the port is an untagged member. You must assign a VLAN ID to a
VLAN. The range is 1 to 4094. The default VLAN has a VLAN ID of 0.
To assign a VLAN ID, do the following:
1. For Windows Server 2003 and Windows XP systems, access the
System Properties Dialog Box. See “Modifying Configuration
Properties” on page 39.
For Windows 2008 R2, Windows 7, and Windows Vista systems, access the Device Manger for your operating system:
To access the Device Manager window in Windows 2008 R2 or
Windows 7, see “Selecting the Device Manager in Windows 2008
To access the Windows Vista Device Manager, see “Selecting the
Device Manager in Windows Vista” on page 46.
2. Click the Advanced tab.
The Advanced tab is shown in Figure 21 on page 56.
3. Under Property list on the Advanced tab, select VLAN ID.
4. From the Value list on the Advanced tab, choose a VLAN ID from 1 to
4094.
Note
The default VLAN has a VLAN ID of 0.
5. Click OK.
6. If prompted to restart your computer, click Yes.
Although it is not necessary to reboot the system for new adapter properties to take effect, rebooting is recommended to reinitialize all registers.
7. Verify that the port LED operates as described in “LEDs” on page 18.
67
Chapter 5: Setting Advanced Properties
Wake Up
Capabilities
The Wake Up Capabilities property enables the network adapter to wake up from a low-power mode when it receives a network wake-up frame.
There are two types of wake-up frames: Magic Packet and Wake Up
Frame. The default setting is Both - which implements both the Magic
Packet and Wake Up Frame.
To change the Wake Up Capabilities property, do the following:
1. For Windows Server 2003 and Windows XP systems, access the
System Properties Dialog Box. See “Modifying Configuration
Properties” on page 39.
For Windows 2008 R2, Windows 7, and Windows Vista systems, access the Device Manger for your operating system:
To access the Device Manager window in Windows 2008 R2 or
Windows 7, see “Selecting the Device Manager in Windows 2008
To access the Windows Vista Device Manager, see “Selecting the
Device Manager in Windows Vista” on page 46.
2. Click the Advanced tab.
The Advanced tab is shown in Figure 21 on page 56.
3. From the Property list on the Advanced tab, select Wake Up
Capabilities.
4. From the Value list on the Advanced tab, select one of the following:
Both - Implements Magic Packet and Wake Up Frame.
Magic Packet - Selects Magic Packet as the Wake Up frame.
None - Selects no wake-up frame.
Wake Up Frame - Selects Wake Up Frame as the wake-up frame and allows the network adapter to wake up the system when an event, such as a ping or an ARP request, is received.
5. Click OK.
WOL Speed
The WOL Speed property sets the speed at which the network adapter connects to the network while the adapter is in Wake on LAN (WOL) mode. On Windows 2008 R2, Windows Vista, and Windows 7 systems, the default speed for WOL mode is 100 Mb. This is the only speed available for an AT-29xx Series adapter running the Windows 2008 R2,
Windows Vista, and Windows 7 operating systems.
68
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
On the Windows Server 2003 or Windows XP systems, this property is available on the AT-2972/T2 adapter only. By default, the WOL Speed property is set to Auto. However, there are several additional settings available.
To specify the WOL speed on a Windows Server 2003 or Windows XP system, perform the following procedure:
1. For Windows Server 2003 and Windows XP systems, access the
System Properties Dialog Box. See “Modifying Configuration
Properties” on page 39.
2. Click the Advanced tab.
The Advanced tab is shown in Figure 21 on page 56.
3. From the Properties list, select WOL Speed.
4. From the Values list, select one of the following:
10 Mb. Sets the speed to 10 Mbit/s. This is the network speed when the system is in a standby mode awaiting a wake-up frame.
100 Mb. Sets the speed to 100 Mbit/s.
Auto (default). Sets the speed for optimum network connection.
5. Click OK.
6. If prompted to restart your computer, click Yes.
Although it is not necessary to reboot the system for new adapter properties to take effect, rebooting is recommended to reinitialize all registers.
7. Verify that the adapter port LEDs operate as described in “LEDs” on page 18.
69
Chapter 5: Setting Advanced Properties
70
Chapter 6
Installing the Linux Driver Software
This chapter describes the Linux driver for the AT-29xx Series Gigabit
Ethernet Network adapters and includes the following sections:
“Installing the Linux Driver Software” on page 72
“Network Installation” on page 74
“Removing the Linux Driver from a TAR Installation” on page 75
“Module Parameters” on page 76
71
Chapter 6: Installing the Linux Driver Software
Installing the Linux Driver Software
The section describes the following Linux driver installations:
“Building a Driver from a TAR File” on page 72
“Removing the tg3 Driver” on page 72
Note
On some newer Distributions and Kernels, it may be necessary to remove the tg3 driver before loading the tg3 driver supplied on the
CD. Follow the instructions in the “Removing the tg3 Driver” on page 72.
Building a Driver from a TAR File
To build a driver from a TAR file, perform the following procedure.
1. Create a directory and extract the TAR files: tar xvzf tg3-<version>.tgz
2. Build the driver tg3.o as a loadable module for the running kernel: cd tg3-
<version>
/src make
3. Test the driver by loading it: insmod tg3.o
4. Install the driver and man page: make install
5. To configure network protocol and address, refer to the manuals supplied with your operating system.
Removing the tg3 Driver
Many various Linux distributions may load the native tg3 driver by default for the Allied Telesis Gigabit Ethernet Network adapters. It may be necessary to unload the native tg3 driver first, before installing the tg3.o driver from this installation.
Note
On some Distributions and Kernels, it may be necessary to remove the native tg3 driver before loading the Allied Telesis tg3.o driver.
72
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
Although tg3 is a fully functioning driver, Allied Telesis recommends that you use the newer tg3 driver provided by Allied Telesis. Use ifconfig to bring down all eth# interfaces used by tg3 and enter the following command to unload the tg3 driver: rmmod tg3
For more detailed Linux specific information on ifconfig, rmmod, or modules.conf, refer to the respective man pages.
73
Chapter 6: Installing the Linux Driver Software
Network Installation
For network installations through NFS, FTP, or HTTP (using a network boot disk or PXE), a driver diskette that contains the tg3 driver may be needed. The driver diskette images for the most recent Red Hat versions are included. Boot drivers for other Linux versions can be compiled by modifying the Makefile and the make environment. Further information is available from Red Hat's website, http://www.redhat.com
.
To create the driver diskette, select the appropriate image file and do the following: dd if=dd.img of=/dev/fd0H1440
74
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
Removing the Linux Driver from a TAR Installation
If the driver was installed using make install from the tar file, you must manually delete the tg3.o driver.
75
Chapter 6: Installing the Linux Driver Software
Module Parameters
Optional parameters for the driver can be supplied as command line arguments to the insmod command. Typically, these parameters are set in the file /etc/modules.conf (see the man page for modules.conf). These parameters take the following form:
<parameter>
=value[,value,...] where the multiple values for the same parameter are for multiple Allied
Telesis Gigabit Ethernet Network adapters installed in the system.
Note
The default or other meaningful values are used when invalid values are selected. Some combinations of parameter values may conflict and lead to failures. The driver cannot detect all such conflicting combinations.
The module parameters are listed below:
line_speed
Selects the line speed of the link. This parameter is used together with full_duplex and auto_speed to select the speed and duplex operation of the link and the setting of Auto-Negotiation. Choose from the following selections:
– 0 - Autonegotiate for highest speed supported by link partner (default)
– 10 - 10 Mbps
– 100 - 100 Mbps
– 1000 - 1000 Mbps
If line_speed is set to 10, 100, or 1000 and the auto_speed is set to 1, the NIC autonegotiates for the selected speed (and selected duplex mode). If auto_speed is set to 0, the selected speed and duplex mode are set without Auto-Negotiation. Note that 1000 Mbps must be negotiated for copper twisted pair links.
auto_speed
Enables or disables Auto-Negotiation. Choose from the following selections:
– 0 - Auto-Negotiation disabled
– 1 - Auto-Negotiation enabled (default)
76
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
Note
This parameter is ignored and assumed to be 1 if the line_speed parameter is set to 0.
full_duplex
This parameter is used together with line_speed to select the speed and duplex mode of the link. Note that this parameter is ignored if line_speed is 0. Choose from the following selections:
– 0 - half duplex
– 1 - full duplex (default)
rx_flow_control
Enables or disables receiving flow control (pause) frames. This parameter is used together with auto_flow_control. Choose from the following selections:
– 0 - pause receive disabled
– 1 - pause receive enabled if auto_flow_control is set to 0, or pause receive advertised if auto_flow_control is set to 1 (default)
tx_flow_control
Enables or disables transmitting flow control (pause) frames. This parameter is used together with auto_flow_control. Choose from the following selections:
– 0 - pause transmit disabled
– 1 - pause transmit enabled if auto_flow_control is set to 0, or pause transmit advertised if auto_flow_control is set to 1 (default)
auto_flow_control
Enables or disables Auto-Negotiation of flow control. This parameter is used together with rx_flow_control and tx_flow_control to determine the advertised flow control capability. Choose from the following selections:
– 0 - flow control Auto-Negotiation disabled
– 1 - flow control Auto-Negotiation enabled with capability specified in rx_flow_control and tx_flow_control (only valid if line_speed is set to 0 or auto_speed is set to 1) (default)
77
Chapter 6: Installing the Linux Driver Software
mtu
Enables jumbo frames up to the specified MTU size. The valid range for this parameter is 1500 to 9000. The default is 1500 which is the standard Ethernet (non-jumbo) MTU size. Note that the MTU size excludes the Ethernet header size of 14 bytes. Actual frame size is
MTU size + 14 bytes.
The MTU size can also be changed using ifconfig after the driver is loaded. See the ifconfig man page for details.
tx_checksum
Enables or disables hardware transmit TCP/UDP checksum. Choose from the following selections:
– 0 - checksum disabled
– 1 - checksum enabled (default)
rx_checksum
Enables or disables hardware receive TCP/UDP checksum validation.
Choose from the following selections:
– 0 - checksum disabled
– 1 - checksum enabled (default)
scatter_gather
Enables or disables scatter-gather and 64-bit DMA on x86. This option is only useful when running on TUX-enabled kernels or kernels with zero-copy TCP. Choose from the following selections:
– 0 - scatter-gather and 64-bit DMA on x86 disabled
– 1 - scatter-gather and 64-bit DMA on x86 enabled
(default)
tx_pkt_desc_cnt
Configures the number of transmit descriptors. Default is 100. The valid range is from 1 to 600. Depending on kernel and system architecture, the driver may require up to 268 bytes per descriptor.
Note that the driver may not be able to allocate the required amount of memory if this parameter is set too high. This parameter should not be set less than 80 if adaptive_coalesce (see below) is enabled.
rx_std_desc_cnt
Configures the number of receive descriptors for frames up to 1528 bytes. Default is 200. The valid range is from 1 to 511. This parameter should not be set less than 80 on systems with high network traffic.
78
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
Setting this parameter higher allows the NIC to buffer larger bursts of network traffic without dropping frames, especially on slower systems.
Note that the driver may not be able to allocate the required amount of memory if this parameter is set too high. This parameter should not be set less than 50 if adaptive_coalesce (see below) is enabled.
rx_jumbo_desc_cnt
Configures the number of receive descriptors for jumbo frames larger than 1528 bytes. The default is 128 and the valid range is from 1 to
255. When jumbo frames larger than 1528 bytes are used, do not set this parameter to lower than 60 on systems with high network traffic.
Setting this parameter higher allows the NIC to buffer larger bursts of jumbo traffic without dropping frames, especially on slower systems.
Depending on kernel and system architecture, the driver may require up to 268 bytes per descriptor. Note that each descriptor also requires a buffer the size of a maximum jumbo frame. On systems with insufficient memory, it may be necessary to reduce this parameter.
This parameter should not be set to less than 50 if adaptive_coalesce
(see below) is enabled. When the maximum frame size is less than
1528 (MTU size less than 1514), this parameter is not used and is always 0.
adaptive_coalesce
Enables or disables adaptive adjustments to the various interrupt coalescing parameters. Enabling it allows the driver to dynamically adjust the interrupt coalescing parameters to achieve high throughput during heavy traffic and low latency during light traffic. Do not set rx_std_desc_cnt (and rx_jumbo_desc_cnt if using jumbo frames) to less than 50. Also, do not set tx_pkt_desc_cnt to less than 80 when this parameter is enabled. Choose from the following selections:
– 0 - disabled
– 1 - enabled (default)
rx_coalesce_ticks
Configures the number of 1 usec ticks before the NIC generates receive interrupt after receiving a frame. This parameter works in conjunction with the rx_max_coalesce_frames parameter. Interrupt is generated when either of these thresholds is exceeded. A value of 0 means this parameter is ignored and an interrupt is generated when the rx_max_coalesce_frames threshold is reached. The valid range is from 0 to 500 and default is 80. This parameter is not used and is adjusted automatically if adaptive_coalesce is set to 1.
79
Chapter 6: Installing the Linux Driver Software
rx_max_coalesce_frames
Configures the number of received frames before the NIC generates receive interrupt. The valid range is from 0 to 100 and the default is 15.
This parameter and rx_coalesce_ticks cannot both have a value of 0. If both parameters are set to 0, no receive interrupts are generated. It should also be set significantly lower than rx_std_desc_cnt (and rx_jumbo_desc_cnt if using jumbo frames). This parameter is not used and is adjusted automatically if adaptive_coalesce is set to 1.
tx_coalesce_ticks
Configures the number of 1 usec ticks before the NIC generates transmit interrupt after transmitting a frame. This parameter works in conjunction with the tx_max_coalesce_frames parameter. Interrupt is generated when either of these thresholds is exceeded. A value of 0 means this parameter is ignored and an interrupt is generated when the tx_max_coalesce_frames threshold is reached. The valid range is from 0 to 500 and the default is 400. This parameter is not used and is adjusted automatically if adaptive_coalesce is set to 1.
tx_max_coalesce_frames
Configures the number of transmitted frames before the NIC generates transmit interrupt. The valid range is from 0 to 100 and the default is 40. This parameter and tx_coalesce_ticks cannot both have a value of 0. If both parameters have a value of 0, no transmit completion interrupt is generated. This parameter should always be set lower than tx_pkt_desc_cnt. This parameter is not used and is adjusted automatically if adaptive_coalesce is set to 1.
stats_coalesce_ticks
Configures the number of 1 usec ticks between periodic statistics block DMAs. The valid range is from 0 to 3600000000, and the default is 1000000 (1 sec.). Set this parameter to a value of 0 to disable statistics updates. This parameter is not used and is set to default if rx_adaptive_coalesce is set to 1.
enable_wol
Enables or disables magic packet Wake-On-LAN when the system is shutdown. Note that not all systems support Wake-On-LAN. Choose from the following selections:
– 0 magic packet Wake-On-LAN disabled (default)
– 1 magic packet Wake-On-LAN enabled
80
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
enable_tso
Enables or disables TCP Segmentation Option (TSO) when using kernels that support it. Choose from the following selections:
– TSO disabled (default)
– TSO enabled
81
Chapter 6: Installing the Linux Driver Software
82
Chapter 7
Installing the Novell NetWare Driver
Software
This chapter provides procedures for installing the Novell NetWare driver software and contains the following sections:
“Driver Installation” on page 84
“Pre-Installation Requirements” on page 85
“Installing Novell NetWare Server 5.x or 6.0 Driver Software” on page 86
“Verifying or Modifying Adapter Parameters” on page 88
“Removing Drivers from Autoexec.ncf” on page 93
83
Chapter 7: Installing the Novell NetWare Driver Software
Driver Installation
This chapter describes how to perform the following tasks:
Verify that the required OS support files are installed on the server and the NetWare pre-installation parameters are set correctly.
Install the driver software in the Novell NetWare environment.
If necessary, reconfigure the driver software after installation.
For an adapter installation with an existing NetWare server, NetWare automatically detects the new adapter and attempts to load the appropriate driver. You can download the latest version of the software driver from the Allied Telesis website at www.alliedtelesis.com/
support/software.
A commonly used method to install a driver on a NetWare server running
5.x or 6.0 and higher is through NWCONFIG.
84
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
Pre-Installation Requirements
A network device driver must be installed before the AT-29xx Series
Gigabit Ethernet network adapters can be used with your Novell NetWare system.
Before you can successfully install the adapter driver for Novell NetWare, the adapter card must be physically installed in the server and, typically, the NetWare OS software must already be running on the server. Make sure that your server meets the hardware and operating system software requirements described Chapter 2, “Installing the Hardware” on page 21.
To enable the Allied Telesis AT-29xx Series Gigabit Ethernet network adapters to function correctly, you need to install the latest Novell NetWare support pack files. The NetWare support pack or patch file(s) needed for
the operating system running on your server are indicated in Table 4.
Table 4. NetWare Support Files
NetWare OS Support Pack or Patch
NetWare 5.1
Latest NetWare 5.1
Support Pack
NetWare 6.0
Latest NetWare 6.0
Support Pack
Files to be Installed
The latest support pack can be found at http:// support.novell.com/ patlst.htm
Note
If you are installing NetWare 5.x or 6.0 for the first time on a system, the process to install the adapter driver occurs during the OS installation procedure. Install the NetWare 5 support pack after you have successfully installed the operating system on the server.
To obtain the latest support pack files, go to the Novell support website and click on the Minimum Patch List option in the navigation bar. Scroll
down the page and, using Table 4 above as a guide, select and download
the latest support pack or patch file(s) for the operating system running on your server.
85
Chapter 7: Installing the Novell NetWare Driver Software
Installing Novell NetWare Server 5.x or 6.0 Driver Software
Check that the server has the latest support pack available installed. The latest support packs can be found at: http://support.novell.com/misc/ patlst.htm
. In addition, you can download the latest version of the software driver from the Allied Telesis website at www.alliedtelesis.com/support/
software
To install the Novell NetWare Server 5.x or 6.0 driver software, perform the following procedure:
1. From the NetWare Server console, type LOAD NWCONFIG (or just
NWCONFIG) and press Enter.
2. From the Configuration Options screen, select Driver options and press Enter.
3. Select the Configure network drivers option and press Enter.
4. Choose the Load an additional driver option and press Enter.
5. Press Enter to select the highlighted driver.
A copy the driver prompt appears.
6. Select Yes and press Enter.
7. Select Yes and press Enter to copy the .LDI file. This is the installation script for the driver.
8. Follow the instructions for the installation.
9. Select Save parameters and load driver to continue.
10. Choose Exit to return to the server console prompt.
Note
If you are performing an initial installation of NetWare 5.x or 6.0 and have more than two adapters installed, the install program allows you to allocate the actual number of packet receive buffers needed by the adapter. During installation, make sure the RxBuffers value is set to 32 which is the minimum number of buffers the driver requires for each adapter. While this setting affects adapter performance, it allows installation of the operating system and up to eight adapters during the initial installation. After installation is complete, increase the number of buffers allocated to the driver as described in
“Verifying or Modifying Adapter Parameters” on page 88.
86
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
11. 5.x or 6.05.x or 6.0 NetWare 5.x or 6.0 has been successfully installed, set the minimum packet receive buffers parameter in the startup.ncf file to 1500 for each adapter in the system.
Set the maximum packet receive buffers to three times the minimum packet receive buffers. Typically 4 MB of RAM is required per 1000
receive buffers. For more information, see “Verifying or Modifying
Adapter Parameters” on page 88.
12. In the autoexec.ncf file, delete the packet receive buffers parameter
(RxBuffers=32) in the load statement for this adapter. Deleting the receive buffers phrase from the load statement resets the receive buffers parameter to the default value of 200 for this adapter.
Note
The server needs to be restarted for the new configuration.
Example: The default maximum number of receive buffers for the system is 500; the default minimum is 128. Edit the startup.ncf file to have the following entries. The actual numbers will be a function of the number of ports in the system. The following is an example for a system with 8 ports installed: set maximum packet receive buffers = 36000 set minimum packet receive buffers = 12000
87
Chapter 7: Installing the Novell NetWare Driver Software
Verifying or Modifying Adapter Parameters
When an adapter configuration is saved, the NetWare install program adds load and bind statements to the autoexec.ncf file. By accessing this file, you can verify the parameters configured for each adapter, modify them, or enter additional parameters.
Note
The Novell monitor program and the config command are also useful for verifying driver configuration. For information on how to use these programs, see the Utilities Reference in your Novell
NetWare online documentation.
The parameters that can be defined in the load statements are described below:
Configuration Parameters for B57.LAN driver:
TxDescriptors=
This is to initialize Descriptor resources on the adapter for transmits.
Min = 100
Max = 512
Default = 120
RxBuffers=
This is to pre-allocate receive ECBs & Receive adapter resources. This setting may be affected by the NetWare server maximum/minimum packet receive buffer settings.
Min = 32
Max = 1000
Default = 200
RxTicks=
This is to enable the use of batching receives within a specific time period.
Min = 0, disabled
Max = 5000000, 5 seconds
Units are in micro seconds
Default value is 300
TxTicks=
This is to enable the use of a transmit "tick" threshold interrupt within a specific time period.
Min = 0, disabled
Max = 5000000, 5 seconds
Units are in micro seconds
Default is 200
88
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
TxPacketsPer=
This is to enable the use of allowing an interrupt to occur after a specific amount of packets are transmitted.
Min = 0, disabled
Max = 100
Default is 20
RxPacketsPer=
This is to enable the use of allowing an interrupt to occur after a specific amount of packets are received.
Min = 0, disabled
Max = 100
Default is 75
CheckSum=
This is to enable or disable the transmit & receive checksum off loading feature.The checksum off loading support is only for TCP/IP packets, for that reason it is defaulted to OFF.
Choices are:
OFF, ON, TX, RX
Default value is OFF
TxFlow=
This keyword allows enabling/disabling of TxFlow control.
Choices are:
ON, OFF
Default value is OFF.
RxFlow=
This keyword allows enabling/disabling of RxFlow control.
Choices are:
ON, OFF
Default value is OFF.
PDriver=
Allows for the driver to operate in persistent driver mode. Only use if adapter is placed in a Hot Plug PCI slot and only if required to swap with an exact same board.
Choices are:
OFF, ON
Default value is OFF.
NODE=
This is a Novell NetWare keyword.
This keyword will allow an input Ethernet node address to replace the adapter factory programmed Ethernet node address until a subsequent reboot.
Choices are:
NODE=nnnnnnnnnnnn
89
Chapter 7: Installing the Novell NetWare Driver Software
FRAME=
This is a Novell NetWare keyword.
String specifying the frame type.
Choices are:
ETHERNET_II
ETHERNET_802.3
ETHERNET_802.2
ETHERNET_SNAP
Default value is ETHERNET_802.2
SLOT=
This is a Novell NetWare keyword.
System-wide unique Hardware Instance Number (HIN) that may be the physical slot number on a slot based bus such as PCI.
SLOT=n
Jumbo=
Keyword to enable Jumbo frame support. When enabled, jumbo packets of up to 9000 bytes are supported.
Choices are:
Jumbo=1536-9100
Default is no jumbo packets
Note
Jumbo frames are only supported on NetWare 6.0 and above. Plus the first frame loaded must be ETHERNET_II
Note
Jumbo frame support must have the following text in the Startup.ncf file: "Set maximum physical receive packet size = 18000".
P3=
This keyword is used when running perform3.exe tests and may increase performance on networks running with many ipx clients.
Set P3=1, when running the perform3 test back to back to a single client.
Set P3=2, when running the perform3 test with many clients.
Default: P3=0.
Spuriousfix=
When this keyword is set to 1 (spurious fix is on), the spurious interrupts count that is sometimes displayed on the NetWare console monitor, may be reduced. By setting this keyword to 0 (spurious fix is OFF), performance of the driver may be enhanced.
90
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
The Default is spurious fix = 1 (spurious fix is on).
Choices are:
Spuriousfix=0
Spuriousfix=1 (default).
Poll=
To disable interrupt driven mode in the driver set Poll=1 and the driver will not use interrupts, but will be polled by the NetWare OS. This is a common feature supported in NW. The poll mode may increase driver performance in some environments.
Choices are:
Poll=1 (ON)
Poll=0 (OFF) (default).
WireSpeed=
This feature provides adapter link & data integrity even when attached to a questionable cable and/or switch.
For example; an adapter trying to run 1000 speed on a cat3 cable ordinarily would not link. With the
WireSpeed=1, the link will occur at 100Mbs.
Choices are:
WireSpeed=1 (ON) (Default)
WireSpeed=0 (OFF).
Model=
This keyword is to allow the addition of a sub-system ID of a specific NIC so that the driver loads only on the first NIC found with a matching sub-system ID.
e.g., MODEl= 0x14e4
Default = 0
MagicP=
When the MagicP=1 the driver will enable the adapter to wake up the system when a magic packet is received after the system is shutdown. MagicP=0 is the default setting with the adapter having no wake up ability.
Choices are:
MagicP=0 (default)
MagicP=1
Fiber=
The driver has support for the 1000FD fiber adapter. The fiber autonegotiates link with a fiber switch even though it only supports 1000FD. In some cases the user may want to force the adapter to 1000FD.
Choices are:
Fiber=AUTO (default)
Fiber=FORCE
91
Chapter 7: Installing the Novell NetWare Driver Software
Note
If you modify any adapter parameters, you must reboot the system before the changes take effect. If you make changes and do not reboot, you may experience configuration problems.
A valid autoexec.ncf file is shown below. One set of load and bind commands (in bold) is added for each frame type the adapter is configured to support.
Set Time Zone = PST8PDT set Daylight Savings Time Offset = 1 set Start Of Daylight Savings Time = (APRIL SUNDAY FIRST
2:00:00 AM) set End Of Daylight Savings Time = (OCTOBER SUNDAY LAST
2:00:00 AM) set Default Time Server Type = SINGLE set Bindery Context = O=LAN
# WARNING!!
file server name NOVELLSERVER51
# WARNING!!
# If you change the name of this server, you must update
# all the licenses that are assigned to this server.
# Using NWAdmin, double-click on a license object and
# click on the Certificate Assignments button. If the
# old name of this server appears, you must delete it and
# then add the new server name. Do this for all license
# objects.
ServerID 1C8EE2C
LOAD ODINEB.NLM
LOAD TCPIP
LOAD B57 SLOT=2 FRAME=Ethernet_802.2 NAME=B57_1_E82
BIND IPX B57_1_E82 NET=FAFD3D25
LOAD B57 SLOT=2 FRAME=Ethernet_802.3 NAME=B57_1_E83
BIND IPX B57_1_E83 NET=5A2D8D6D
LOAD B57 SLOT=2 FRAME=Ethernet_SNAP NAME=B57_1_ESP
BIND IPX B57_1_ESP NET=477A35BD
LOAD B57 SLOT=2 FRAME=Ethernet_II NAME=B57_1_EII
BIND IPX B57_1_EII NET=C3C8F2E4
BIND IP B57_1_EII ADDR=172.16.1.1 MASK=ff.ff.ff.0
mount all
SEARCH ADD SYS:\JAVA\BIN
SEARCH ADD SYS:\JAVA\NWGFX
92
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
Removing Drivers from Autoexec.ncf
To remove the drivers from the Autoexec.ncf, locate the Load and Bind command lines associated with the Broadcom driver and remark them out by inserting the # symbol at the beginning of each command line, or by deleting the statement.
Example:
# LOAD B57 SLOT=2 FRAME=Ethernet_802.2
NAME=B57_1_E82
# BIND IPX B57_1_E82 NET=FAFD3D25
# LOAD B57 SLOT=2 FRAME=Ethernet_802.3
NAME=B57_1_E83
# BIND IPX B57_1_E83 NET=5A2D8D6D
# LOAD B57 SLOT=2 FRAME=Ethernet_SNAP NAME=B57_1_ESP
# BIND IPX B57_1_ESP NET=477A35BD
# LOAD B57 SLOT=2 FRAME=Ethernet_II NAME=B57_1_EII
# BIND IPX B57_1_EII NET=C3C8F2E4
# BIND IP B57_1_EII ADDR=172.16.1.1 MASK=ff.ff.ff.0
Note
If you modify the Autoexec.ncf, you must reboot the system before the changes take effect.
93
Chapter 7: Installing the Novell NetWare Driver Software
94
Chapter 8
Installing the NDIS2 Driver Software for
MS-DOS Platforms
This chapter provides procedures for installing the NDIS2 driver software. and contains the following sections:
“Installing the NDIS2 Driver Software for Use on MS-DOS Platforms” on page 96
“Using Keywords for the B57.dos Drivers” on page 101
95
Chapter 8: Installing the NDIS2 Driver Software for MS-DOS Platforms
Installing the NDIS2 Driver Software for Use on MS-DOS Platforms
Pre-Installation
Requirements
Modifying the
Startup Disk
You can run the NDIS2 driver software from an MS-DOS startup disk using Microsoft Network Client 3.0.
Before you can successfully install the NDIS2 driver software, the
Allied Telesis AT-29xx Series Gigabit Ethernet Network adapter must be physically installed in the computer.
To modify the startup disk, perform the following procedure:
1. Edit A:\Net\Protocol.ini with Notepad or a similar text editor. a. Change DriverName=$ to DriverName=B57$. b. Remove all other parameter entries under the [MS$NE2CLONE] or equivalent section such as IOBASE=0x300 or INTERRUPT=3, and so on.
Example Protocol.ini for IP
[network.setup] version=0x3110 netcard=ms$ne2clone,1,MS$NE2CLONE,1 transport=tcpip,TCPIP lana0=ms$ne2clone,1,tcpip
[MS$NE2CLONE]
DriverName=B57$
[protman]
DriverName=PROTMAN$
PRIORITY=MS$NDISHLP
[tcpip]
NBSessions=6
DefaultGateway=0 ; SubNetMask=255 0 0 0
; IPAddress=192 168 0 1
DisableDHCP=0
DriverName=TCPIP$
96
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
BINDINGS=MS$NE2CLONE
LANABASE=0
Example Protocol.ini for IPX
[network.setup] version=0x3110 netcard=ms$ne2clone,1,MS$NE2CLONE,1 transport=ms$ndishlp,MS$NDISHLP transport=ms$nwlink,MS$NWLINK lana0=ms$ne2clone,1,ms$nwlink lana1=ms$ne2clone,1,ms$ndishlp
[MS$NE2CLONE]
DriverName=B57$
[protman]
DriverName=PROTMAN$
PRIORITY=MS$NDISHLP
[MS$NDISHLP]
DriverName=ndishlp$
BINDINGS=ms$ne2clone
[ms$nwlink]
DriverName=nwlink$
FRAME=Ethernet_802.2
BINDINGS=MS$NE2CLONE
LANABASE=0
Example Protocol.ini for NetBEUI
[network.setup] version=0x3110 netcard=ms$ne2clone,1,MS$NE2CLONE,1 transport=ms$ndishlp,MS$NDISHLP transport=ms$netbeui,MS$NETBEUI
97
Chapter 8: Installing the NDIS2 Driver Software for MS-DOS Platforms lana0=ms$ne2clone,1,ms$ndishlp lana1=ms$ne2clone,1,ms$netbeui
[MS$NE2CLONE]
DriverName=B57$
[protman]
DriverName=PROTMAN$
PRIORITY=MS$NDISHLP
[MS$NDISHLP]
DriverName=ndishlp$
BINDINGS=MS$NE2CLONE
[MS$NETBEUI]
DriverName=netbeui$
SESSIONS=10
NCBS=12
BINDINGS=MS$NE2CLONE
LANABASE=0
2. Edit A:\Net\System.ini. a. Change netcard= to netcard=b57.dos. b. Check for references to C:\NET and change C:\NET to A:\NET if necessary.
Example SYSTEM.INI
[network] sizworkbuf=1498 filesharing=no printsharing=no autologon=yes computername=MYPC lanroot=A:\NET username=USER1 workgroup=WORKGROUP
98
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide reconnect=yes dospophotkey=N lmlogon=0 logondomain= preferredredir=basic autostart=basic maxconnections=8
[network drivers] netcard=B57.dos
transport=ndishlp.sys,*netbeui devdir=A:\NET
LoadRMDrivers=yes
3. Copy B57.dos to A:\Net.
4. Create the appropriate Autoexec.bat file in drive A for the chosen protocol as shown below.
For TCP/IP
path=a:\net a:\net\net initialize a:\net\netbind.com
a:\net\umb.com
a:\net\tcptsr.exe
a:\net\tinyrfc.exe
a:\net\nmtsr.exe
a:\net\emsbfr.exe
a:\net\net start basic net use z: \\SERVERNAME\SHARENAME
For IPX
SET PATH=A:\NET
A:\NET\net initialize
A:\NET\nwlink
99
Chapter 8: Installing the NDIS2 Driver Software for MS-DOS Platforms
A:\NET\NET START BASIC net use z: \\SERVERNAME\SHARENAME
For NetBEUI
SET PATH=A:\NET
A:\NET\NET START BASIC net use z: \\SERVERNAME\SHARENAME
5. Create a Config.sys file on the startup disk in drive A as shown below. files=30 device=a:\net\ifshlp.syslastdrive=z
100
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
Using Keywords for the B57.dos Drivers
The Protocol.ini file contains certain keywords that are used by the
B57.dos drivers. These keywords are listed below:
BusNum. Specifies the PCI bus number on which the network controller is located. Requires a decimal number having a value ranging from 0 to 255.
DevNum. Specifies the device number assigned to the network controller when it is configured by the PCI BIOS. Requires a decimal number having a value ranging from 0 to 255.
FuncNum or PortNum. Specifies the PCI function or port number assigned to the network controller. Requires a decimal number having a value ranging from 0 to 7.
Note
The BusNum, DevNum, and FuncNum (or PortNum) keywords are needed when multiple controllers are installed in the computer and when a specific controller must be loaded in a certain order. These keywords are used concurrently and are included for manufacturing purposes. Do not use them unless you are familiar with how to configure PCI devices. A PCI device scan utility is needed to find this information.
NodeAddress. Specifies the network address used by the network controller. If a multicast address or a broadcast address is specified, the controller uses the default MAC address.
Example
[B57]
DriverName = "B57$"
BusNum = 3
DevNum = 14
PortNum = 2
LineSpeed = 1000
Fuplex = Full
NodeAddress = 001020304050
101
Chapter 8: Installing the NDIS2 Driver Software for MS-DOS Platforms
102
Chapter 9
Installing the PXE Boot Agent
This chapter describes the PXE Boot Agent and provides procedures for installing it on a server running Windows Server 2003, Windows XP, DOS
UNDI/APITEST, or Red Hat Linux system.
This chapter contains the following sections:
103
Chapter 9: Installing the PXE Boot Agent
Overview
The Allied Telesis AT-29xx Series Gigabit Ethernet network adapters provide PXE (Preboot Execution Environment) support.
PXE is enabled by default. To enable or disable PXE, refer to the b57udiag.pdf document located in the diagnostics directory.
Setup BIOS
To boot from the network with PXE, make PXE the first bootable device under BIOS. This procedure depends on server BIOS implementation.
Please refer to the server's user manual.
104
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
Server Setup
This section discusses how to set up a server on a Windows Server 2003,
Windows XP, DOS UNDI/APITEST, and Red Hat Linux systems.
Note
If pack 3 is installed, no modification to the inf file is necessary.
Windows Server
2003 and
Windows XP
The current version of Windows Server 2003 does not include network drivers for the Allied Telesis Gigabit Ethernet adapters. To do remote installation with PXE, include a network driver for the adapter as a part of the client's installation image on the server. Please refer to Microsoft
Article ID Q246184 - " How to Add Third-Party OEM Network Adapters to
RIS Installations.
" An example of this RIS installation to modify your inf file, refer to the troubleshooting section under Software Problems and
Solutions .
DOS UNDI/
APITEST
To boot in DOS and connect to a network for the DOS environment, download the Intel® PXE PDK from the Intel Web site. This PXE PDK comes with a TFTP/ProxyDHCP/Boot server. The PXE PDK can be downloaded from Intel at http://developer.intel.com/ial/WfM/tools/pxe/ index.htm
.
Red Hat Linux
Red Hat Linux 7.3 (or higher) distribution has PXE server support. It allows you to do a complete Linux installation over the network. Distribution also comes with boot images - boot kernel (vmlinuz) and initial ram disk (initrd).
The following images can be found on the Red Hat distribution CD-ROM disk#1:
/images/pxeboot/vmlinuz
/images/pxeboot/initrd.img
Refer to Red Hat documentation for how to install PXE server on Linux. In this version, it prompts you to insert a driver disk for drivers that are not part of the standard distribution. You can create a driver disk for the adapter from the image distributed on the Allied Telesis web site.
A remote boot does not require a standard Linux network driver for the adapter. After the PXE client downloads the Linux kernel and initial ram disk, the Linux universal driver that came with the Linux distribution binds with the UNDI code of the PXE to form a Linux network driver.
105
Chapter 9: Installing the PXE Boot Agent
106
Chapter 10
Troubleshooting
This chapter describes troubleshooting procedures and contains the following sections:
“Hardware Diagnostics” on page 108
“Checking Port LEDs on the Adapter” on page 109
“Troubleshooting Checklist” on page 110
“Verifying the Correct Drivers are Loaded” on page 111
“Testing Network Connectivity” on page 112
“Software Problems and Solutions” on page 115
107
Chapter 10: Troubleshooting
Hardware Diagnostics
Loopback diagnostic tests are available for testing the adapter hardware under Windows. These tests provide access to the adapter's internal or external diagnostics, where packet information is transmitted across the physical link.
108
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
Checking Port LEDs on the Adapter
The adapter has two LEDs: LINK and ACT. The LINK LED indicates an active link and the ACT (Activity) LED indicates data transfer status. Once the driver is loaded and the cables are connected properly. The LINK LED is lit and the ACT LED is on if data traffic is present.
Before the port LEDs can provide troubleshooting information, the adapter must be connected to the network (see Chapter 2, “Installing the
Hardware” on page 21) and the network drivers for your particular operating system must be installed.
1. Verify that the adapter driver software has been installed and that the adapter is connected to a network.
2. Check to see that the LEDs operate as described in Table 5.
Table 5. Fiber Optic Port LED Status
LED State
Description
LINK
ACT
On
Off
Blinking
Off
Valid fiber link.
No fiber link.
Data traffic is present between the card and the switch.
Data traffic is not present.
109
Chapter 10: Troubleshooting
Troubleshooting Checklist
The following checklist provides recommended actions to take to resolve problems installing the Allied Telesis AT-29xx Series Gigabit Ethernet
Network adapter or running it in your system.
Warning
Before opening the cabinet of your system for removing or inserting the adapter, please review all precautions outlined under “Reviewing
Safety Precautions” on page 22.
Inspect all cables and connections. Verify that the cable connections between the adapter and the switch are attached properly. Make sure that the cable length and rating are compliant with the requirements listed in “Connecting the Network Cables” on page 29."
Check the adapter installation by reviewing Chapter 2, “Installing the
Hardware” on page 21.
Make sure that the adapter board is properly seated in a PCI slot.
Check for specific hardware problems, such as obvious damage to board components or the PCI edge connector.
Check the configuration settings and change them if they are in conflict with another device.
Make sure that your system is using the latest BIOS.
Try inserting the adapter in another slot. If the new position works, the original slot in your system may be defective.
Replace the failed adapter with one that is known to work properly. If the second adapter works in the slot where the first one failed, the original adapter is probably defective.
Install the adapter in another functioning system and run the tests again. If the adapter passed the tests in the new system, the original system may be defective.
Remove all other adapters from the system and run the tests again. If the adapter passes the tests, the other adapters may be causing contention.
110
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
Verifying the Correct Drivers are Loaded
The following section describes how to check if the correct drivers are loaded for NetWare and Linux.
NetWare
To verify that the NetWare driver software is loaded correctly, perform the following procedure.
1. To verify that the driver is loaded properly, type:
LOAD B57.LAN FRAME_ETHERNET_II NAME=B57_1_EII
This command automatically verifies if the link is active. If the link is active, it displays "Link is up".
2. From the command line, type config then press Enter.
The following status information is displayed:
Broadcom NetXtreme Gigabit Adapter
Version:
Hardware Setting:
Node Address:
Frame Type:
Board Name:
Lan Protocol: ARP (see note)
LAN Protocol: IP Addr: (see note)
Note
The LAN protocol status appears after assigning an IP address to the adapter (that is, bind).
Linux
To verify that the Linux driver software is loaded correctly, perform the following procedure.
1. To verify that the tg3.o driver is loaded properly, run: lsmod
If the driver is loaded, a line similar to the one below appears, where
<size> is the size of the driver in bytes, and <n> is the number of
adapters configured. See Table 6.
Table 6. Linux Driver Software Information
Module
tg3
Size
<size>
Used by
<n>
111
Chapter 10: Troubleshooting
Testing Network Connectivity
The following section describes how to test network connectivity for
Windows Server 2003, NetWare, and Linux networks.
Note
When using forced link speeds, make sure that both the adapter and the switch are forced to the same speed. Or, make sure at least one link partner is configured for Auto-Negotiation.
Windows Server
2003
To test the network connectivity for the Windows Server 2003 driver software, perform the following procedure.
Use the ping command to determine if network connectivity is working.
1. Select Run from the Windows Control Panel
The Run command window opens, as shown in Figure 22.
Figure 22. Run Command Window
2. Type cmd and click OK.
3. Type ipconfig /all
The command window opens, as shown in Figure 23 on page 113.
112
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
Figure 23. Command Window with pconfig/all displayed
4. Type ping <IP address> from the command line, then press Enter.
The network connectivity information is displayed, as shown in
Figure 24. Command Window with ping displayed
113
Chapter 10: Troubleshooting
NetWare
To ping an IP host on the network to verify a connection has been established, perform the following procedure.
1. From the command line, type ping <IP address>, then press Enter.
This command displays the packet send/receive status.
Linux
To verify that the Ethernet interface is up and running, run ifconfig to check the status of the Ethernet interface. In addition, you can also use the netstat -i command to check the statistics on the Ethernet interface. Consult the manual pages for more information about the ifconfig
and netstat commands.
To ping an IP host on the network to verify connection has been established, perform the following procedure.
1. From the command line, type ping <IP address>. Then press Enter.
This command displays the packet send/receive status.
114
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
Software Problems and Solutions
Microsoft Remote
Installation
Service (RIS)
Instructions
Problem: Microsoft Remote Installation Service (RIS) installation fails for
Windows XP.
Solution: Refer to Microsoft Article Q246184, "How to Add Third-Party
OEM Network Adapters to RIS Installations."
Windows XP Image
To deploy a Windows XP Image, follow the steps in the Microsoft Article
Q246184 at http://support.microsoft.com/default.aspx?scid=kb%3benus%3b246184 .
Windows Server
2003
This section lists known problems and solutions when Windows Server
2003.
Problem: IP address is configurable on a member of the team.
Solution: When a team is created, the TCP/IP properties for the adapters are unselected. Then you can select and configure TCP/IP properties of the adapters and configure an IP address manually.
Problem: When creating 64 VLANs, all virtual adapters show disconnected or one of the 64 VLANs show disabled.
Solution: The maximum VLAN configurations are 63 tagged and one untagged VLAN ID 0. If 64 tagged VLANs are created, they are disconnected. A reboot is required and only 63 tagged VLANs show links, while a 64th is disabled.
Miscellaneous
The following table lists known miscellaneous problems and solutions:
Problem: When the bus on the system is operating at PCI mode, the adapter performs at PCI mode if it is added by the Hot Plug application.
Solution: When the system is booted up without an adapter, the bus operates at the lowest mode which is PCI. This problem can be corrected by rebooting the system.
Problem: The adapter may not perform at optimal level when it is added by the Hot Plug application on some systems.
Solution: The system BIOS, in some systems, does not set the cache line size and the latency timer, after the adapter is added by the Hot Plug application. This problem can be corrected by rebooting the system.
Problem: The adapter cannot be seen on the PCI BUS.
115
Chapter 10: Troubleshooting
Solution: This is because some of the older servers are advertising themselves as PCI-X capable systems. This causes the adapter to operate in PCI-X mode; therefore; it is not seen by the PCI bus. This problem can be corrected by configuring the firmware to operate in forced pci mode. Refer to b57diag for configuration instructions.
116
Chapter 11
DOS Diagnostics
This chapter describes the DOS diagnostics and contains the following sections:
“DOS Prompt Commands” on page 119
“Diagnostic Tests” on page 120
117
Chapter 11: DOS Diagnostics
Introduction
This chapter describes how to use the DOS diagnostic utilities program on an Allied Telesis AT-29xx Series Gigabit Ethernet Network adapter. As a prerequisite, the AT-29xx DOS Diagnostics requires a bootable DOS partition.
You can enter a command from the DOS prompt or the command line interface (CLI) prompt. Otherwise, the parameter is used as an executable command and then exits the program.
For the latest DOS diagnostics and User Guide, visit the
www.alliedtelesis.com/support/software website.
118
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
DOS Prompt Commands
Table 7 lists the DOS prompt commands.
Table 7. DOS Prompt Commands
Command Description
-c <num>
-cmd
-w <value>
Specify adapter to be tested and/or modified
Enter command mode
Enable/Disable (value = 1/0) WOL in manufacture mode
-mba <value>
-mbap <value>
-mbas <value>
Option to select MBA protocol
0 = Disable
1 = Enable
Option to select MBA protocol
0 = PXE
1 = RPL
2 = BOOTP
Option to select MBA speed
0 = auto
1 = 10HD
2 = 10FD
3 = 100HD
4 = 100FD
6 = 1000FD (fiber)
-firm <file name> Update devices eeprom based on <file name> image match to HW
-ver Version of the current software/ eeprom.bin
-pxe <file name> Programming PXE firmware from file
-elog <file name> Output error to log file
119
Chapter 11: DOS Diagnostics
Diagnostic Tests
The tests are divided into four groups: Register Tests, Memory Tests,
Miscellaneous Tests, and Data Tests. They are named group ‘A’, ‘B’, ‘C’, and ‘D’.
Test Names
This section lists the groups and the names of the diagnostics tests.
Group A.
A1. Indirect Register Test
A2. Control Register Test
A3. Interrupt Test
A4. BIST
A5. PCI Cfg Register Test
Group B.
B1. Scratch Pad Test
B2. BD SRAM Test
B3. DMA SRAM Test
B4. MBUF SRAM Test
B5. MBUF SRAM via DMA Test
B6. External SRAM Test
Group C.
C1. EEPROM Test
C2. CPU Test
C3. DMA Test
C4. MII Test
C5. VPD Test
C6. ASF Test
C7. ROM Expansion Test
Group D.
D1. Mac Loopback Test
D2. Phy Loopback Test
D3. RJ45 Loopback Test
D4. MII Miscellaneous Test
D5. MSI Test
120
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
Test Descriptions
This section provides descriptions of the diagnostic tests.
A1. Indirect Register Test
Function: Using indirect addressing method, writing increment data into
MAC hash Register table and read back for verification. The memory read/ write is done 100 times while increment test data.
Default: Test Enabled
A2. Control Register Test
Function: Each Register specified in the configuration contents read only bit and read/write bit defines. The test writing zero and one into the test bits to insure the read only bits are not changed, and read/write bits are changed accordingly.
Default: Test Enabled.
A3. Interrupt Test
Function: This test verifies the interrupt functionality. It enables interrupt and waits for interrupt to occur. It waits for 500ms and reports error if could not generate interrupts.
Default: Enabled
A4. BIST
Function: Hardware Built-In-Self-Test (BIST). This test initiates BIST and waits for the test result returned by hardware.
Default: Due to the intermittent failure, this test is currently disabled by default.
A5. PCI Cfg Register Test
Function: This test verifies the access integrity of the PCI config registers.
B1. Scratch Pad Test
Function: This test tests the scratch pad SRAM on board. The following tests are performed:
Data Pattern Test: Writes test data into the SRAM and reads it back to ensure data is correct. The test data used is 0x00000000, 0xFFFFFFFF,
0xAA55AA55, and 0x55AA55AA.
Alternate Data Pattern Test: Writes test data into the SRAM. Writes complement test data into the next address. Reads back both to insure the
121
Chapter 11: DOS Diagnostics data is correct. After the test, the program reads back data one more time to insure the data stays correct. The test data used is 0x00000000,
0xFFFFFFFF, 0xAA55AA55, and 0x55AA55AA.
Address Test: Writes each address with unique increment data. Read back data to insure data is correct. After fill the entire data with the unique data, the program reads back data again to insure data stays the same.
WalkingOne bit Test: For each address, data one is written and read back for testing. Then shift the data left one bit, so the data becomes two and perform the same test again. It repeats for 32 times until the test bit is shifted out of test data. The same is test is repeated for entire test range.
Pseudo Random Data Test: A pre-calculated pseudo random data is used to write a unique data into each test RAM. After the first pass the test, the program reads back one more time to insure data stays correct.
Default: Enabled
B2. BD SRAM Test
Function: This test tests the BD SRAM. This performs exact the same way of testing as described in B1. Scratch Pad Test.
Default: Enabled
B3. DMA SRAM Test
Function: It tests DMA SRAM by performing the tests described in test
B1. The Scratch Pad Test.
Default: Enabled
B4. MBUF SRAM Test
Function: It tests DMA SRAM by performing the tests described in test
B1. The Scratch Pad Test.
Default: Enabled
B5. MBUF SRAM via DMA Test
Function: Eight test pattern data are used in the test. They are described below. A 0x1000 sized data buffer is used for this test. Before each pattern test, the buffer is initialized and filled with the test pattern. It then performs size 0x1000 transmit DMA from host buffer to NIC MBUF memory. Verify the data integrity in MBUF against host memory and repeat the DMA for the entire MBUF buffer. Then it performs receive DMA from NIC to host.
The 0x1000-byte test buffer is cleared to zero before each receive-DMA.
Verify the data integrity and test is repeated for the entire MBUF SRAM
range. See Table 8 on page 123.
122
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
Test Pattern
"16 00's 16 FF's"
"16 FF's 16 0's"
"32 00's 32 FF's"
"32 FF's 32 00's"
"00000000's"
"FFFFFFFF's"
"AA55AA55's"
"55AA55AA's"
Table 8. DMA Test Patterns
Description
Full the entire host DMA buffer with 16 bytes of 00’s and then 16 bytes of FF’s.
Full the entire host DMA buffer with 16 bytes of FF’s and then 16 bytes of 00’s.
Full the entire host DMA buffer with 32 bytes of 00’s and then 32 bytes of FF’s.
Full the entire host DMA buffer with 32 bytes of FF’s and then 32 bytes of 00’s.
Full the entire host DMA buffer with all zeros.
Full the entire host DMA buffer with all
FF’s.
Full the entire host DMA buffer with data
0xAA55AA55.
Full the entire host DMA buffer with data
0xAA55AA55.
Default: Enabled
B6. External SRAM Test
Function: It tests DMA SRAM by performing the tests described in test
B1. The Scratch Pad Test.
Default: Disabled
C1. EEPROM Test
Function: An increment test data is used in EEPROM test. It fills the test data into the test range and read back to verity the content. After the test, it fills data with zero to clear the memory.
Default: Enabled
C2. CPU Test
Function: This test opens the file cpu.bin. If file exists and content is good, it loads code to rx and tx CPU and verifies CPU execution.
Default: Enabled
123
Chapter 11: DOS Diagnostics
C3. DMA Test
Function: Both high and low priorities DMA are tested. It moves data from the host memory to NIC SRAM, verifies data, and then moves data back to the host memory again to verify data.
Default: Enabled
C4. MII Test
Function: The function is identical to A2. Control Register Test. The test writing zero and one into the test bits to insure the read only bits value are not changed, and read/write bits are changed accordingly.
Default: Test Enabled.
The test attempts to read the register configuration file ‘miireg.txt’ for the register defines. If the file does not exists, the following table is used. See
Table 9. Default Register
Offset R/O Mask R/W Mask
0x00 0x0000 0x7180
0x02 0xffff 0x0000
0x03 0xffff 0x0000
0x04 0x0000 0xffff
0x05 0xefff 0x0000
0x06 0x0001 0x0000
0x07 0x0800 0xb7ff
0x08 0xffff 0x0000
0x09 0x0000 0xff00
0x0a 0x7c00 0x0000
0x10 0x0000 0xffbf
0x11 0x3300 0x0000
0x19 0x001f 0x0000
0x1e 0x0000 0xffff
0x1f 0x0000 0xffff
124
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
C5. VPD Test
Function: It saves the content of VPD first before perform the test. Once it is done, it writes one of the five pattern test data, 0xFF, 0xAA, 0x55, increment data, or decrement data, into VPD memory. By default, increment data pattern is used. It writes and reads back the data for the entire test range, and then restores the original content.
Default: Disabled
C6. ASF Test
Function: m
1. Reset test.
Setting reset bit, poll for self-clearing. Verify reset value of registers.
2. Event Mapping Test
Setting SMB_ATTN bit. By changing ASF_ATTN LOC bits, verify the mapping bits in TX_CPU or RX_CPU event bits.
3. Counter Test
Clear WG_TO, HB_TO, PA_TO, PL_TO, RT_TO bits by setting those bits. Make sure the bits clear.
Clear Timestamp Counter. Writing a value 1 into each PL, PA, HB,
WG, RT counters. Set TSC_EN bit.
Poll each PA_TO bit and count up to 50 times. Check if PL_TO gets set at the end of 50 times. Continue to count up to 200 times. Check if all other TO bits are set and verify Timestamp Counter is incremented.
C7. ROM Expansion Test
Function: This function tests the ability to enable/disable/access the expansion ROM on the device.
D1. Mac Loopback Test
Function: This is internal loopback data transmit/receive test. It initializes the MAC into internal loopback mode and transmits 100 packets. The data should be routed back to the receive channel and received by the receive routine which verifies the integrity of data. One Gigabit rate is used for this test.
Default: Enabled
125
Chapter 11: DOS Diagnostics
D2. Phy Loopback Test
Function: This test is same as D1. Mac Loopback Test except, the data is routed back via physical layer device. One Giga bit rate is used for this test.
Default: Enabled
D3. RJ45 Loopback Test
Function: This is external loopback test. From the UUT point of view, no loopback mode is configured. The data expected to be routed back by
RJ45 loopback connector. 100M/s and 1000M/s are used for this test.
Default: Disabled
D4. MII Miscellaneous Test
Function: This function tests the auto-polling and phy-interrupt capabilities.
Default: Enabled
D5. MSI Test
Function:
Default: Disabled
126
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
Error Messages
/* 0 */ "PASS",
/* 1 */ "Got 0x%08X @ 0x%08X. Expected 0x%08X",
/* 2 */ "Cannot perform task while chip is running",
/* 3 */ "Invalid NIC device",
/* 4 */"Read only bit %s got changed after writing zero at offset 0x%X",
/* 5 */ "Read only bit %s got changed after writing one at offset 0x%X",
/* 6 */ "Read/Write bit %s did not get cleared after writing zero at offset 0x%X",
/* 7 */"Read/Write bit %s did not get set after writing one at offset 0x%X",
/* 8 */ "BIST failed",
/* 9 */ "Could not generate interrupt",
/* 10 */ "Aborted by user",
/* 11 */ "Tx DMA:Got 0x%08X @ 0x%08X. Expected 0x%08X",
/* 12 */ "Rx DMA:Got 0x%08X @ 0x%08X. Expected 0x%08X",
/* 13 */ "Tx DMA failed",
/* 14 */ "Rx DMA failed",
/* 15 */ "Data error, got 0x%08X at 0x%08X, expected
0x%08X",
/* 16 */ “Second read error, got 0x%08X at 0x%08X, expected
0x%08X",
/* 17 */ "Failed writing EEPROM at 0x%04X",
/* 18 */ "Failed reading EEPROM at 0x%04X",
/* 19 */ "EEPROM data error, got 0x08X at 0x04X, expected
0x%08X",
/* 20 */ "Cannot open file %s",
/* 21 */ "Invalid CPU image file %s",
/* 22 */ "Invalid CPU image size %d",
/* 23 */ "Cannot allocate memory",
127
Chapter 11: DOS Diagnostics
/* 24 */ "Cannot reset CPU",
/* 25 */ "Cannot release CPU",
/* 26 */ "CPU test failed",
/* 27 */ "Invalid Test Address Range\nValid NIC address is
0x%08X-0x%08X and exclude 0x%08X-0x%08X",
/* 28 */ "DMA:Got 0x%08X @ 0x%08X. Expected 0x%08X",
/* 29 */ "Unsupported PhyId %04X:%04X",
/* 30 */ "Too many registers specified in the file, max is
%d",
/* 31 */ "Cannot write to VPD memory",
/* 32 */ "VPD data error, got %08X @ 0x04X, expected %08X",
/* 33 */ "No good link! Check Loopback plug",
/* 34 */ "Cannot TX Packet!",
/* 35 */ "Requested to Tx %d. Only %d is transmitted",
/* 36 */ "Expected %d packets. Only %d good packet(s) have been received\n%d unknown packets have been received.\n%d bad packets have been received.",
/* 37 */ "%c%d is an invalid Test",
/* 38 */ "EEPROM checksum error",
/* 39 */ "Error in reading WOL/PXE",
/* 40 */ "Error in writing WOL/PXE",
/* 41 */ "No external memory detected",
/* 42 */ "DMA buffer %04X is large, size must be less than
%04X",
/* 43 */ "File size %d is too big, max is %d",
/* 44 */ "Invalid %s",
/* 45 */ "Failed writing 0x%x to 0x%x",
/* 46 */ "",
/* 47 */ "Ambiguous command",
/* 48 */ "Unknown command",
/* 49 */ "Invalid option",
128
AT-29xx Series Gigabit Ethernet Network Adapters Installation Guide
/* 50 */ "Cannot perform task while chip is not running.
(need driver)",
/* 51 */ "Cannot open register define file or content is bad",
/* 52 */ "ASF Reset bit did not self-cleared",
/* 53 */ "ATTN_LOC %d cannot be mapped to %cX CPU event bit
%d",
/* 54 */ "%s Register is not cleared to zero after reset",
/* 55 */ "Cannot start poll_ASF Timer",
/* 56 */ "poll_ASF bit did not get reset after acknowledged",
/* 57 */ "Timestamp Counter is not counting",
/* 58 */ "%s Timer is not working",
/* 59 */ "Cannot clear bit %s in %cX CPU event register",
/* 60 */ "Invalid "EEPROM_FILENAME" file size, expected %d but only can read %d bytes",
/* 61 */ "Invalid magic value in %s, expected %08x but found
%08x",
/* 62 */ "Invalid manufacture revision, expected %c but found %c",
/* 63 */ "Invalid Boot Code revision, expected %d.%d but found %d.%d",
/* 64 */ "Cannot write to EEPROM",
/* 65 */ "Cannot read from EEPROM",
/* 66 */ "Invalid Checksum",
/* 67 */ "Invalid Magic Value",
/* 68 */ "Invalid MAC address, expected %02X-%02X-%02X-%02X-
%02X-%02X",
/* 69 */ "Slot error, expected an UUT to be found at location %02X:%02X:00",
/* 70 */ "Adjacent memory has been corrupted while testing block 0x%08x-0x%08x\nGot 0x%08x @ address
0x%08x. Expected 0x%08x",
/* 71 */ "The function is not Supported in this chip",
/* 72 */ "Packets received with CRC error",
129
Chapter 11: DOS Diagnostics
/* 73 */ "MII error bits set: %04x",
/* 74 */ "CPU does not initialize MAC address register correctly",
/* 75 */ "Invalid firmware file format",
/* 76 */ "Resetting TX CPU Failed",
/* 77 */ "Resetting RX CPU Failed",
/* 78 */ "Invalid MAC address",
/* 79 */ "Mac address registers are not initialized correctly",
/* 80 */ "EEPROM Bootstrap checksum error",
130
Appendix A
Specifications
Physical Specifications
This section lists the dimensions and weights of all of the AT-29xx Series adapters.
Dimensions: AT-2916SX: 11.98 cm x 6.4 cm (4.72 in x 2.53 in)
AT-2916LX10/LC-901: 11.98 cm x 6.4 cm (4.72 in x 2.53 in)
AT-2931SX: 16.75 cm x 6.4 cm (6.6 in x 2.53 in)
AT-2972SX: 16.75 cm x 6.8 cm (6.6 in x 2.67 in)
AT-2972SX/2: 16.8 cm x 6.8 cm (6.7 in x 2.7 in)
AT-2972T/2: 16.75 cm x 6.8 cm (6.6 in x 2.67 in)
AT-2972LX10/LC-901:16.75 cm x 6.8 cm (6.6 in x 2.67 in)
Weight: AT-2916SX: 70 g (.15 lb)
AT-2916LX10/LC-901: 70 g (.15 lb)
AT-2931SX: 60 g (.12 lb)
AT-2972SX: 64 g (.14 lb)
AT-2972SX/2: 70 g (.15 lb)
AT-2972T/2: 64 g (.14 lb)
AT-2972LX10/LC-901: 64 g (.14 lb)
Environmental Specifications
The following environmental specifications apply to all of the AT-29xx
Series adapters.
Operating Temperature:
Storage Temperature:
Operating Humidity:
0°C to 55°C (+32°F to +131°F)
-40°C to +85°C (-40°F to +185°F)
5% to 85% (noncondensing) 40°C, 16 hour dwells at extremes
Storage Humidity: 5% to 95% (noncondensing) 10°C/hour
Operating Altitude Range: 10,000
Storage Altitude Range 35,000 ft.
131
Appendix A: Specifications
Operating Shock:
Storage Shock:
Operating vibration, peak to peak displacement
Storage vibration, peak to peak displacement
Operating vibration, peak acceleration:
Storage vibration, peak acceleration
10g, 1/2 sine wave, 11 msec
60g, 1/2 sine wave, 11 msec
0.005 in. max (5 to 32 Hz)
0.1 in. max (5 to 17 Hz)
0.25g (5 to 500 Hz) (Sweep Rate = 1 octave/ min.)
0.25g (5 to 500 Hz) (Sweep Rate = 1 octave/ min.)
Power Specifications
The operating voltage specification in this section applies to all of the AT-
29xx Series adapters. The power consumption specifications apply to the individual adapter listed.
Operating Voltage: 3.3V +/-10%
Power Consumption: AT-2916SX: 3.86 Watts, 1.17A@ +3.3V
AT-2916LX10/LC-901: 4.19 Watts, 1.27A @ +3.3V
AT-2931SX: 3.86 Watts, 1.17A@ +3.3V
AT-2972SX: 6.6 Watts, 2A@ +3.3V
AT-2972SX/2: 7.26 Watts, 2A@ +3.3V
AT-2972T/2: 7.26 Watts, 2A@ +3.3V
AT-2972LX10/LC-901: 6.93 Watts, 2.1A@ +3.3V
Performance Specifications
The performance specifications in this section for PCI and PCI-X apply to all of the AT-29xx Series adapters. The PCI, PCI-X, and PCI-E specifications apply to the individual adapter listed.
PCI clock:
PCI-X clock:
33/66 MHz max
133 MHz
PCI or PCI-X Data/Address: AT-2916SX 32-bit only
AT-2916LX10/LC-901 32-bit only
AT-2931SX 32-bit and 64-bit
132
PCI-E
AT-29xx Series Gigabit Ethernet Adapters Installation Guide
AT-2972SX
AT-2972SX/2
4 channel
4 channel
AT-2972LX10/LC-901 4 channel
Operating Specifications
The following operating specifications apply to all of the AT-29xx Series adapters.
Output Optical Power:
Input Optical Power:
Receive Sensitivity:
-9.5 dBm minimum to -4 dBm maximum
-17 dBm to 0 dBm maximum
-12.5 dBm with 62.5 um fiber or
-13.5 dBm with 50 um fiber
133
Appendix A: Specifications
134
Appendix B
Cleaning Fiber Optic Connectors
The fiber optic connector consists of a fiber optic plug and its adapter. The end of the fiber optic cable is held in the core of the ferrule in the plug.
Light signals are transmitted through the core of the fiber. Even minor smudges or dirt on the end face of the fiber, completely invisible to the naked eye, can disrupt light transmission and lead to failure of the component or of the entire system. Therefore, it is of utmost importance to clean all fiber optic connectors before use.
Figure 25 shows the ferrule in an SC connector.
177
Ferrule
Figure 25. Ferrule in an SC Connector Plug
Figure 26 shows part of the end face of an unclean and clean ferrule.
156
Unclean Clean
Figure 26. Unclean and Clean Ferrule
This appendix provides the following procedures
“Using a Cartridge-Type Cleaner” on page 136
135
Appendix B: Cleaning Fiber Optic Connectors
Using a Cartridge-Type Cleaner
Fiber optic cartridge cleaners are available from many vendors and are
typically called “cartridge cleaners,” as shown in Figure 27.
TAPE A ing n ctio
Wip Dire
Figure 27. Cartridge Cleaner
Note
Do not use compressed air or aerosol air to clean a fiber optic connector.
To clean a fiber optic connector using a cartridge cleaner, perform the following procedure.
1. With one hand, hold the cartridge cleaner and push the lever on the cleaning cartridge in the direction of the arrow to expose the cleaning
surface, as shown in Figure 28.
2. Place the ferrule tip on the exposed cleaning surface and rub the
ferrule in a downward direction, as shown in Figure 28.
136
Figure 28. Rubbing the Ferrule Tip on the Cleaning Surface
AT-29xx Series Gigabit Ethernet Adapters Installation Guide
Note
Rub the ferrule tip on the cleaning surface in one direction only.
3. When you reach the end of the cleaning surface, pick up the ferrule tip, rotate and place it at the top and rub downwards at least 2 times.
Caution
Failing to pick up the ferrule tip when you reach the bottom of the cleaning surface can result in static electricity that can damage the fiber optic cable.
4. If desired, repeat steps 3 and 4.
5. If a fiber inspection scope is available, use the scope to inspect the ferrule end face to make sure that it is clean.
6. Reconnect the cable to the port or protect the ferrule tip with a dust cap.
Note
Always keep a dust cap on a fiber optic cable when it is not in use.
Note
Do not touch the end face of the ferrule in the connector.
Warning
Do not stare into the laser beam.
L2
Warning
Do not look directly at the cable ends or inspect the cable ends with an optical lens.
E29
137
Appendix B: Cleaning Fiber Optic Connectors
Using a Swab
Specially treated swabs (stick cleaners) are available for cleaning inside connector adapters or hard-to-reach ferrule tips. These swabs, often referred to as “lint free” or “alcohol free” swabs, are available from many
vendors, as shown in Figure 29. Stick cleaners are available in both 2.5
mm and 1.25 mm sizes for use on SC and MU connectors respectively.
Note
NEVER use a household cotton swab and/or alcohol to clean a fiber optic connector. This may leave a residue on the ferrule tip.
Figure 29. Lint-Free and Alcohol-Free Swabs
Note
Do not use compressed air or aerosol air to clean a fiber optic connector.
To clean a recessed ferrule using a swab, perform the following procedure.
1. Insert the swab into the adapter as shown in Figure 28 and rub the
ferrule tip with the swab.
157
Figure 30. Cleaning a Recessed Ferrule
2. If desired, repeat step 1.
138
AT-29xx Series Gigabit Ethernet Adapters Installation Guide
3. If a fiber inspection scope is available, use the scope to inspect the connector to make sure that it is clean and to check for scratches, pits, or other problems that may affect performance.
Note
Always keep a dust cap on a fiber optic cable when it is not in use.
Warning
Do not stare into the laser beam.
L2
Warning
Do not look directly at the cable ends or inspect the cable ends with an optical lens.
E29
139
Appendix B: Cleaning Fiber Optic Connectors
140
advertisement
Related manuals
advertisement
Table of contents
- 12 Safety Symbols Used in this Document
- 13 Where to Find Web-based Guides
- 14 Contacting Allied Telesis
- 14 Online Support
- 14 Email and Telephone Support
- 14 Warranty
- 14 Returning Products
- 14 Sales or Corporate Information
- 14 Management Software Updates
- 15 Introduction to the AT-29xx Series Gigabit Ethernet Network Adapters
- 16 Functional Description
- 17 Contents of Your Shipment
- 18 LEDs
- 19 AT-29xx Series Adapter Software Drivers
- 19 Supported Operating Systems
- 19 Software Driver Features
- 20 Failover Teaming
- 21 Installing the Hardware
- 22 Reviewing Safety Precautions
- 24 Pre-Installation Checklist
- 25 Installing a Network Adapter Card
- 29 Connecting the Network Cables
- 30 Warranty Registration
- 31 Installing Windows Server 2003 and Windows XP Driver Software
- 32 Installing the Driver Software
- 32 Using the Driver Installer
- 35 Updating the Adapter Software
- 39 Modifying Configuration Properties
- 41 Uninstalling the Driver Software
- 43 Installing the Windows 2008 R2, Windows Vista, and Windows 7 Driver Software
- 44 Installing the Driver Software
- 44 Selecting the Device Manager
- 48 Installing the Windows 2008 R2, Windows, Vista, and Windows 7 Driver Software
- 51 Uninstalling the Driver Software
- 53 Setting Advanced Properties
- 54 Opening Advanced Properties
- 55 802.1p QOS
- 57 Ethernet@Wirespeed™ (AT-2972/T2 only)
- 57 Flow Control
- 58 Jumbo Mtu
- 59 Interrupt Moderation
- 60 IPSec Offload
- 61 Large Send Offload Property
- 62 Network Address
- 63 Priority & VLAN
- 64 Receive Side Scaling
- 65 Speed & Duplex Mode
- 66 Checksum Offload
- 67 VLAN ID
- 68 Wake Up Capabilities
- 68 WOL Speed
- 71 Installing the Linux Driver Software
- 72 Installing the Linux Driver Software
- 72 Building a Driver from a TAR File
- 74 Network Installation
- 75 Removing the Linux Driver from a TAR Installation
- 76 Module Parameters
- 83 Installing the Novell NetWare Driver Software
- 84 Driver Installation
- 85 Pre-Installation Requirements
- 86 Installing Novell NetWare Server 5.x or 6.0 Driver Software
- 88 Verifying or Modifying Adapter Parameters
- 93 Removing Drivers from Autoexec.ncf
- 95 Installing the NDIS2 Driver Software for MS-DOS Platforms
- 96 Installing the NDIS2 Driver Software for Use on MS-DOS Platforms
- 96 Pre-Installation Requirements
- 96 Modifying the Startup Disk
- 101 Using Keywords for the B57.dos Drivers
- 103 Installing the PXE Boot Agent
- 104 Overview
- 104 Setup BIOS
- 105 Server Setup
- 105 Windows Server 2003 and Windows XP
- 105 DOS UNDI/ APITEST
- 105 Red Hat Linux
- 107 Troubleshooting
- 108 Hardware Diagnostics
- 109 Checking Port LEDs on the Adapter
- 110 Troubleshooting Checklist
- 111 Verifying the Correct Drivers are Loaded
- 111 NetWare
- 111 Linux
- 112 Testing Network Connectivity
- 112 Windows Server 2003
- 114 NetWare
- 114 Linux
- 115 Software Problems and Solutions
- 115 Microsoft Remote Installation Service (RIS) Instructions
- 115 Windows Server 2003
- 115 Miscellaneous
- 117 DOS Diagnostics
- 118 Introduction
- 119 DOS Prompt Commands
- 120 Diagnostic Tests
- 120 Test Names
- 121 Test Descriptions
- 127 Error Messages
- 131 Specifications
- 131 Physical Specifications
- 131 Environmental Specifications
- 132 Power Specifications
- 132 Performance Specifications
- 133 Operating Specifications
- 135 Cleaning Fiber Optic Connectors
- 136 Using a Cartridge-Type Cleaner
- 138 Using a Swab