Viessmann Main Documentation Vitocal 100-AW Operating instructions
PDF
Dokument
Oglas
Oglas
Installation, Service and Operating Instructions viesmann b for use by heating contractor Vitocal 100-AW AM2V Models 020028, 0340043 and 051078 Outdoor Air to Water Heat Pump Indoor Distribution and Control Unit Heating Capacity: 20.5 to 58 MBH 6 to 17 kW Cooling Capacity: 1.4 to 4.3 Ton 5 to 15 kW VITOCAL 100-AW Product may not be exactly as shown IMPORTANT Read and save these instructions for future reference. 6221389 - 02 03/2024 Please file in Service Binder Safety Vitocal 100-AW AM2V Installation, Service and Operating About these Instructions Take note of all symbols and notations intended to draw attention to potential hazards or important 1 product information. These include “WARNING”, “CAUTION”, and “IMPORTANT”. See below. 1 WARNING uWarnings draw your attention to the presence of potential hazards or important product information. Indicates an imminently hazardous situation which, if not avoided, could result in death, serious injury or substantial product/property damage. 1 CAUTION uCautions draw your attention to the presence of potential hazards or important product information. Indicates an imminently hazardous situation which, if not avoided, may result in minor injury or product/property damage. IMPORTANT u uHelpful hints for installation, operation or maintenance which pertain to the product. uThis symbol indicates that additional, pertinent Information is to be found. 6221389 - 02 uThis symbol indicates that This symbol indicates that other instructions must be referenced. 2 Vitocal 100-AW AM2V Installation, Service and Operating Safety Safety, Installation and Warranty Requirements Please ensure that these instructions are read and understood before commencing installation. Failure to comply with the instructions listed below and details printed in this manual can cause product/property damage, severe personal injury, and/or loss of life. Ensure all requirements below are understood and fulfilled (including detailed information found in manual subsections). HHProduct documentation Read all applicable documentation before commencing installation. Store documentation near heat pump in a readily accessible location for reference in the future by service personnel. HHLicensed professional heating contractor The installation, adjustment, service and maintenance of this equipment must be performed by a licensed professional heating contractor. u For a listing of applicable literature, please see section entitled “Important Regulatory and Safety Requirements”. HHWarranty Information contained in this and related product documentation must be read and followed. Failure to do so renders the warranty null and void. 6221389 - 02 HHAdvice to owner Once the installation work is complete, the heating contractor must familiarize the system operator/ ultimate owner with all equipment, as well as safety precautions/requirements, shutdown procedure, and the need for professional service annually before the heating season begins. u Please see section entitled “Important Regulatory and Installation Requirements”. 3 Safety Vitocal 100-AW AM2V Installation, Service and Operating Safety, Installation and Warranty Requirements Fiberglass wool and ceramic fiber materials 1 WARNING Inhaling of fiberglass wool and/or ceramic fiber materials is a possible cancer hazard. These materials can also cause respiratory, skin and eye irritation. The state of California has listed the airborne fibers of these materials as a possible cancer hazard through inhalation. When handling these materials, special care must be applied. First aid measures ––If eye contact occurs, flush eyes with water to remove dust. If symptoms persist, seek medical attention. ––If skin contact occurs, wash affected areas gently with soap and warm water after handling. Operating and Service Documentation It is recommended that all product documentation such as parts lists, operating and service instructions be handed over to the system user for storage. Documentation is to be stored near the heat pump in a readily accessible location for reference by service personnel. 6221389 - 02 Suppliers of ceramic fiber products recommend the following first aid measures: ––Respiratory tract (nose and throat) irritation: If respiratory tract irritation develops, move the person to a dust free location. ––Eye irritation: If eyes become irritated, flush Immediately with large amounts of lukewarm water for at least 15 minutes. Eyelids should be held away from the eyeball to ensure thorough rinsing. Do not rub eyes. ––Skin irritation: If skin becomes irritated, remove soiled clothing. Do not rub or scratch exposed skin. Wash area of contact thoroughly with soap and cold water (as warm or hot water may worsen the irritation). Using a skin cream or lotion after washing may be helpful. ––Gastrointestinal irritation: If gastrointestinal tract irritation develops, move the person to a dust free environment. Suppliers of fiberglass wool products recommend the following precautions be taken when handling these materials: ––Avoid breathing fiberglass dust and contact with skin and eyes. ––Use NIOSH approved dust/mist respirator. ––Wear long-sleeved, loose fitting clothing, gloves and eye protection. ––Wash work clothes separately from other clothing. Rinse washer thoroughly. ––Operations such as sawing, blowing, tearout and spraying may generate airborne fiber concentration requiring additional protection. 4 Vitocal 100-AW AM2V Installation, Service and Operating Safety Safety, Installation and Warranty Requirements The outdoor unit contains flammable refrigerant R32. If there is a leak, the escaping refrigerant may form a flammable or explosive atmosphere in the ambient air. 1 WARNING Risk of explosion: Escaping refrigerant may form a flammable or explosive atmosphere in the ambient air. Take the following measures to prevent fire and explosion: HHKeep ignition sources away, e.g. naked flames, hot surfaces, electrical devices not free of ignition sources, mobile devices with integrated batteries (e.g. mobile phones, fitness watches, etc.). HHPermissible tools: All tools for working must be designed and explosion protected in accordance with the applicable standards and regulations for refrigerant in safety groups A2L and A3, e.g. brushless machines (cordless screwdrivers), extraction equipment, disposal containers, installation aids, vacuum pumps, conductive hoses, mechanical tools of non-sparking material, etc. Note: The tools must also be suitable for the pressure ranges in use. Tools must be in good working order. HHDo not use flammable materials, e.g. sprays or other flammable gases. HHDischarge static: Before beginning work, touch earthed objects, such as heating or water pipes. HHDo not remove, block or bridge safety equipment. HHDo not make any changes: Do not modify the outdoor unit, inlet/outlet lines, electrical connections/cables or the surroundings. Do not remove any components or seals. Working on the system HHSwitch off the power supply to the indoor unit and outdoor unit, e.g. at a breaker. Check that the system is no longer live. Note: In addition to the control circuit there may be several power circuits. 6221389 - 02 1 WARNING Contact with live components can result in severe injuries. Some components on PCB’s remain live even after the power supply has been switched off. Prior to removing covers from the appliances, wait at least 4 minutes until the voltage has completely dropped out. 1 WARNING HHSafeguard the system against reconnection. HHWear suitable personal protective equipment when carrying out any work. 1 WARNING Hot surfaces and fluids can result in burns or scalding. Cold surfaces may cause frostbite. HHPrior to servicing or maintenance tasks, switch off and allow the equipment to cool down or warm up. HHDo not touch hot or cold surfaces on the appliance, fittings or pipework. Note: Electronic assemblies can be damaged by electrostatic discharge. Before beginning work, touch earthed objects, such as heating or water pipes, to discharge any static. R32 refrigerant is an air displacing, colorless, flammable gas which forms explosive mixtures with air. Refrigerant drained must be properly disposed of by authorised contractors. Perform the following measures before beginning work on the refrigerant circuit: HHCheck the refrigerant circuit for leaks. HHEnsure very good ventilation especially in the floor area and sustain this for the duration of the work. HHSecure the area surrounding the work area. HHInform the following persons of the type of work to be carried out: – All maintenance personnel – All persons in the vicinity of the system. HHInspect the area immediately around the heat pump for flammable materials and ignition sources: Remove all flammable, movable materials and any ignition sources from the safety zone. HHBefore, during and after the work, check the surrounding area for escaping refrigerant using an explosion-proof refrigerant detector suitable for R32. This refrigerant detector must not generate any sparks and must be suitably sealed. HHA CO2 or powder extinguisher must be to hand in the following cases: – Refrigerant is being drained. – Refrigerant is being topped up. – Soldering or welding work is being carried out. HHDisplay signs prohibiting smoking. 5 Safety Vitocal 100-AW AM2V Installation, Service and Operating Safety, Installation and Warranty Requirements 1 WARNING Escaping refrigerant can lead to fire and explosions that result in very serious injuries or death. HHDo not drill or apply heat to a refrigerant circuit filled with refrigerant. HHDo not operate Schrader valves unless a fill valve or extraction equipment is attached. HHTake measures to prevent electrostatic charge. HHNo smoking! Prevent naked flames and sparks. Never switch lights or electrical appliances on or off. HHComponents that contain or contained refrigerant must be labelled, and stored and transported in well ventilated areas in accordance with the applicable regulations and standards. 1 WARNING Direct contact with liquid and gaseous refrigerant can cause serious damage to health, e.g. frostbite and/or burns. There is a risk of asphyxiation if it is breathed in. HHPrevent direct contact with liquid and gaseous refrigerant. HHWear personal protective equipment when handling liquid and gaseous refrigerant. HHNever breathe in refrigerant vapors. 1 WARNING Refrigerant is under pressure: Mechanical loading of lines and components an cause leaks in the refrigerant circuit. Do not apply loads to the lines and components, e.g. by supporting or placing tools. 1 WARNING Hot and cold metallic surfaces of the refrigerant circuit may cause burns or frostbite if skin contact is made. Wear personal protective equipment to protect against burns or frostbite. 1 WARNING Damage to the refrigerant circuit can cause refrigerant to enter the hydronic system. After completion of the work, vent the hydronic system Damage to the refrigerant circuit can cause refrigerant to enter the hydronic system. After completion of the work, vent the hydronic system correctly. When doing so, ensure the area is sufficiently ventilated. Installation Frost protection. Note: Freezing can cause damage to the heat pump. HHThermally insulate all the hydronic lines. HHIn order to activate the frost protection function, electrically connect the heat pump before filling the secondary circuit. Switch on the power supply. Switch on the ON/OFF switch on the indoor unit. 1 WARNING With short electrical cables, should there be leakage in the refrigerant circuit, gaseous refrigerant may reach the inside of the building. Min. length of the electrical connecting cables between the indoor and the outdoor unit: 3 m Note: Repairing components that fulfil a safety function can compromise the safe operation of the system. HHReplace faulty components only with genuine Viessmann spare parts. HHDo not undertake any repairs on the inverter. Replace the inverter if there is a defect. Note: Spare and wearing parts that have not been tested together with the system can compromise its function. Installing non-authorised components and making non-approved modifications or conversions can compromise safety and may invalidate our warranty. For replacements, use only original spare parts supplied or approved by Viessmann. 6221389 - 02 Note: When refrigerant is being removed, hydronic components may freeze. Drain heating water from the heat pump beforehand. 6 Vitocal 100-AW AM2V Installation, Service and Operating Safety Safety, Installation and Warranty Requirements 1 WARNING Escaping refrigerant can lead to fire and explosions that result in very serious injuries or death. HHEnsure very good ventilation especially in the floor area of the outdoor unit. HHNo smoking! Prevent naked flames and sparks. Never switch lights or electrical appliances on or off. HHEvacuate any people from the danger zone. HHFrom a safe position, switch off the electricity supply for all system components. HHRemove ignition sources HHLet the system user know that no ignition source may be brought into area for the duration of the repair. HHRepair work must be carried out by an authorised contractor. HHOnly recommission the system after it has been repaired. 1 WARNING Direct contact with liquid and gaseous refrigerant can cause serious damage to health, e.g. frostbite and/or burns. Prevent direct contact with liquid and gaseous refrigerant. 1 WARNING Breathing in refrigerant may cause suffocation. Never breathe in refrigerant vapors. 1 WARNING If water escapes from the appliance there is a risk of electric shock. Switch off the heating system at the external isolator (e.g. fuse box, domestic distribution board). 1 WARNING Note: A build-up of ice in the condensate pan and in the fan area of the outdoor unit can cause damage to the equipment. Please note the following: HHDo not use mechanical items/aids for the removal of ice. HHBefore using electrical heating appliances, check the refrigerant circuit for leaks with a suitable measuring device. HHThe heating appliance should not be a source of ignition. HHIf ice regularly builds up on the outdoor unit (e.g. in areas where frost and heavy fog occur frequently), install fan ring heating (accessories) that is suitable for refrigerant R32 and/or an electric ribbon heater in the condensate pan (accessories or factory-fitted). HHThe outdoor unit is charged at the factory with refrigerant R32. 1 WARNING Escaping refrigerant can lead to fire and explosions that result in very serious injuries or death. There is a risk of asphyxiation if it is breathed in. Store the outdoor unit in the following conditions: HHAn explosion prevention plan must be in place for storage. HHEnsure there is sufficient ventilation at the storage location. HHTemperature range for storage: -13°F to 158°F (–25°C to 70°C) HHOnly store the outdoor unit in its factory protective packaging. HHProtect the outdoor unit against damage. HHThe maximum number of outdoor units that may be stored in one place is determined by local conditions. 6221389 - 02 If water escapes from the appliance, there is a risk of scalding. Never touch hot heating water. 7 Table of Contents Vitocal 100-AW AM2V Installation, Service and Operating Index Safety About these Instructions.................................................................... 2 Safety, Installation and Warranty Requirements.................................... 3 Table of Contents Index............................................................................................... 8 General Information Important Regulatory and Installation Requirements............................... 10 Mechanical Room.............................................................................. 10 Applicability..................................................................................... 11 Product Information........................................................................... 12 Intended Use.................................................................................... 14 System Examples.............................................................................. 14 Fittings and Sealing Points................................................................. 14 Prior to Installation............................................................................ 14 Indoor Unit Installation Dimensions...................................................................................... 15 Recommended Minimum Service Clearances......................................... 16 Mounting the Indoor Unit................................................................... 16 Accessing the Indoor Unit.................................................................. 17 Piping Connections............................................................................ 18 Domestic Hot Water.......................................................................... 19 Safety Valve.................................................................................... 20 Installation Fittings............................................................................ 21 Electrical Connections........................................................................ 22 Power Supply Indoor Unit................................................................... 23 Outdoor Unit Installation Dimensions...................................................................................... 24 Recommended Minimum Service Clearances......................................... 26 Outdoor Unit Sound Pressure.............................................................. 28 Prior to Installation............................................................................ 29 Mounting on a Concrete Pad.............................................................. 30 Mounting using a Mounting Curb........................................................ 31 Mounting on Stand............................................................................ 32 Safety Valve.................................................................................... 33 Piping Connections............................................................................ 34 Accessing the Outdoor Unit................................................................ 35 Power Supply Outdoor Unit................................................................ 36 Communication................................................................................. 37 Installation Examples Installation Examples......................................................................... 38 System Example 1............................................................................ 39 System Example 2............................................................................ 40 System Example 3............................................................................ 41 User Interface................................................................................... 42 Display Symbols and Indications......................................................... 43 Initial Start-up................................................................................... 44 Diagnostics Menu............................................................................. 44 Settings Menu.................................................................................. 44 Setting the Room Temperature........................................................... 45 Setting the DHW Temperature............................................................ 45 8 6221389 - 02 Operating Vitocal 100-AW AM2V Installation, Service and Operating Table of Contents Index Setting a Time Schedule.................................................................... 46 DHW Tank Hygiene Function.............................................................. 49 Setting Time and Date....................................................................... 50 Adjusting the Interface...................................................................... 50 Setting the Language......................................................................... 51 System Information........................................................................... 51 Time Schedule Override..................................................................... 52 Service/Configuration Menu................................................................ 53 Adjusting the Heating Curve............................................................... 58 Service Troubleshooting................................................................................ 60 Fault Codes Indoor Unit..................................................................... 62 Fault Codes Outdoor Unit................................................................... 62 Preparing for Service......................................................................... 66 Check Sensors.................................................................................. 66 Checking Fuses................................................................................ 67 Maintenance..................................................................................... 68 Wiring Indoor Unit Wiring Diagram................................................................ 72 Outdoor Unit Wiring Diagram.............................................................. 74 Parts Parts List......................................................................................... 77 Technical Data Indoor Unit Technical Data................................................................. 88 Outdoor Unit Technical Data............................................................... 89 Water Quality 6221389 - 02 Filling the System............................................................................. 90 9 General Information Vitocal 100-AW AM2V Installation, Service and Operating Important Regulatory and Installation Requirements Codes In Canada all electrical wiring is to be done in accordance with the latest edition of CSA C22.1 Part 1 and/or local codes. In the U.S., use the National Electrical Code ANSI/NFPA 70. Instructing the system user The installer of the system is responsible to ensure the system operator/ultimate owner is made familiar with the system functioning, its activation, and its shut-down. Initial start-up Initial start-up must be performed by a qualified heating contractor. Proper completion of the Maintenance Record by the heating contractor is also required. Working on the equipment The installation, adjustment, service, and maintenance of this heat pump must be done by a licensed professional heating contractor who is qualified and experienced in the installation, service, and maintenance of heat pumps. There are no user serviceable parts on the heat pump. Ensure main power supply to equipment, the heating system, and all external controls has been deactivated. Take precautions in all instances to avoid accidental activation of power during service work. Technical literature Leave all literature at the installation site and advise the system operator/ultimate owner where the literature can be found. Contact Viessmann for additional copies. This product comes with several safety instruction labels attached. Do not remove! Contact Viessmann immediately if replacement labels are required. Literature for the Vitocal 100-AW AM2V Series: ––Technical Data Manual ––Installation, Service and Operating Instructions ––Instructions of other products utilized and installed ––Installation codes mentioned in this manual and as locally applicable The completeness and functionality of field supplied electrical controls and components must be verified by the heating contractor. These include flow switches (if used), staging controls, pumps, motorized valves, air vents, thermostats, etc. Leave all literature at the installation site and advise the system operator/ultimate owner where the literature can be found. Contact Viessmann for additional copies. This product comes with several safety instruction labels attached. Do not remove! Contact Viessmann immediately if replacement labels are required. Mechanical Room During the early stages of designing a new home, we recommend that proper consideration be given to constructing a separate mechanical room dedicated to the heat pump equipment and domestic hot water storage tank(s). The indoor unit must be located in a heated indoor area, near a floor drain. Whenever possible, install the unit near an outside wall so that it is easy to connect the indoor unit to the outdoor unit. Locate the indoor unit on a wall capable of supporting 100 lb. (45 kg) [the weight of the indoor unit]. 6221389 - 02 The maximum room temperature of the mechanical room where the indoor unit is located must not exceed 95°F (35°C). 10 General Information Vitocal 100-AW AM2V Installation, Service and Operating Applicability 1 CAUTION The serial number must be provided when ordering replacement parts. Some replacement parts are not reverse compatible with previous versions of the Vitocal 100-AW AM2V. 4 5 IMPORTANT When ordering replacement parts, provide the 16-digit serial number which is found on either the indoor unit rating plate or outdoor unit rating plate. Indoor Unit: Model No. AM2V 020028 AM2V 034043 AM2V 051078 Serial No. 7228973jjjjjjjjj 7228974jjjjjjjjj 7228975jjjjjjjjj Outdoor Unit: Model No. AM2V 020028 AM2V 034043 AM2V 051078 Serial No. 7986309jjjjjjjjj 7986310jjjjjjjjj 7986311jjjjjjjjj 1 2 3 Product may not be exactly as shown 1 Integrated resistive heating element 2 Integrated Space Heating/DHW Production diverting valve 3 Integrated system pump 4 Integrated system expansion tank 5 Monochrome digit interface Certifications Indoor Unit S 1 4 3 Outdoor Unit 2 Product may not be exactly as shown 6221389 - 02 1 Coil 2 Fan 3 Compressor 4 Brazed plate heat exchanger 11 General Information Vitocal 100-AW AM2V Installation, Service and Operating Product Information The Vitocal 100-AW AM2V heat pump is designed for heating/cooling of a building and heating domestic hot water. The unit consists of two modules: Outdoor Unit Indoor Unit The working principle of the unit is to capture heat from the environment and to transfer it to the heating circuit in the building. The low-temperature heat of the air is transferred through an evaporator to the heat pump system filled with a refrigerant, which turns into a gas as it evaporates. From the evaporator, the gas is drawn in by the compressor, which raises its temperature during its compression and directs it to the condenser. In the condenser, heat is transferred to the refrigerant, which fills the central heating system, and the cooled liquid flows through the expansion valve and returns to the evaporator, after which the whole process starts again. In the case of cooling, this cycle is reversed and the heat is extracted from the building and discharged outside. The working principle of the unit is based on the demand-dependent capacity control of the heat pump compressor with an activation of the electrical auxiliary heater via the controller of the indoor module. The indoor module controller regulates the heating output according to a preset heating curve. If the heat pump is not able to cover the building’s heating demand on its own, the controller automatically activates the electrical auxiliary heater which, together with the heat pump produces the desired heating medium temperature. Outdoor temperature ranges for air-to-water heat pumps All the components of the refrigeration circuit are located in the outdoor module, including the refrigeration circuit controller with an electronic expansion valve. Depending on the operating conditions, the compressor power is adjusted by means of an inverter. When the space cooling function is activated, the refrigeration circuit is reversed. Air-to-water heat pumps use the outdoor air as the heat source. Operation is only efficient within certain outdoor temperature ranges, e.g. between -13°F and 113°F (-25°C and +43°C). If the upper temperature limit is exceeded or the lower temperature limit has been reached, heat pumps switch off periodically. A corresponding notification appears on the heat pump controller. To cover the heat demand for space heating and tap water heating beyond the temperature limits, the heat pump controller automatically switches on the available auxiliary heating equipment, e.g. electric auxiliary heating, if necessary. Plumbing system Required equipment The indoor and outdoor modules are connected to each other via heating medium hydronic lines. A high-efficiency circulation pump (secondary pump) built into the indoor module supplies the heating medium to the secondary circuit. A central 3-way diverter valve: “space heating/DHW heating DHW” is responsible for switching between space heating and hot tap water heating. A communication bus cable between the outdoor module and the indoor module. Recommended: LiYY 2 x 0.34mm2 max: 2 x 1.5mm2 Refrigeration circuit Heat pump controller HHSpace heating The heat pump may heat up to 2 heating/cooling circuits: 1 heating/cooling circuit without a mixer and 1 heating/cooling circuit with a mixer. HHSpace cooling The heat pump may cool via up to 2 heating/ cooling circuits. 6221389 - 02 The entire heating system is monitored and controlled by the heat pump controller. The heat pump controller is integrated into the indoor module. Communication between the indoor and outdoor modules takes place via a communication bus. Installation with heating/cooling buffer storage tank 12 Vitocal 100-AW AM2V Installation, Service and Operating General Information Product Information Wall mounted indoor unit in combination with air to water outdoor unit heat pump, with the following integrated components: HHHeating or cooling operation HHHydronics with 3-way diverter valve and variable speed high efficiency circulation pump HHWeather-compensated or constant temperature control unit HHDHW production Heat pump model must be selected based on an accurate heat loss calculation of the building. Ensure heat pump model is compatible with connected radiation. A The rating plate of the Vitocal 100 AW contains extensive product information and is heat pumpspecific. Access code with the marking “i” for direct access to product-specific information and product registration on the internet. The access code contains the credentials for the registration and product information portal, as well as the 16-digit serial number. 6221389 - 02 A Rating plate for indoor unit registration 13 General Information Vitocal 100-AW AM2V Installation, Service and Operating Intended Use The Vitocal 100 is only intended to be installed and operated in sealed unvented heating systems with due attention paid to the associated installation, service and operating instructions. The heat pump is only designed for: HHSpace Heating HHSpace Cooling HHDHW Heating Commercial or industrial use for a purpose other than the heating of heating water shall be deemed inappropriate. Intended use presupposes that a permanent installation in conjunction with permissible components designed for this purpose has been carried out. All other use is deemed inappropriate. Any resulting losses are excluded from the manufacturer’s liability. Any usage beyond this must be approved by the manufacturer in each individual case. Intended use also includes adherence to maintenance and inspection intervals. System Examples System examples with hydronic and electrical connection schemes and function descriptions are available to help setting up the heating system, refer to “Installation Examples” on page 38. Fittings and Sealing Points All connections must be fitted with new gaskets/ seals after opening or loosening. 1 WARNING Risk of electric shock from escaping heating water or DHW. When commissioning and after carrying out maintenance work, check all water side connections for leaks. Prior to Installation 1 CAUTION The indoor unit must be installed in such a way that the system components are protected from water (spraying, splashing, etc.) during operation and service. 6221389 - 02 Before placing Vitocal 100 AW in its installation location, ensure all necessary accessories are installed. 14 Indoor Unit Installation Vitocal 100-AW AM2V Installation, Service and Operating Dimensions A B C D E F F G H I J 5-b (138) 2 (48) 11-a (283) 7-b (190) 2-a (55) Legend A B C D E F G c in. Electrical Knockouts (2 per side) b in. Electrical Knockouts (8 per side) Return to Heat Pump (1-a in. NPT) Supply to Space Heating (1-a in. NPT) DHW/Space Heating Return (1-a in. NPT) Supply from Heat Pump (1-a in. NPT) DHW Tank Heating Supply (1-a in. NPT) 6221389 - 02 Dimensions in. (mm) A 16-a (416) B 28-b (723) C 12-c (323) D 28-a (717) E 11-a (285) G 15 Indoor Unit Installation Vitocal 100-AW AM2V Installation, Service and Operating Recommended Minimum Service Clearances Recommended minimum service clearances For typical installation, it is recommended to install the indoor unit with the clearances shown in the illustration. A - 12 in. (300 mm) B - 20 in. (500 mm) Front Clearance 39 in. (1000 mm) These dimensions reflect the recommended service clearance for the indoor unit only, ensure adequate clearance is left for the installation of piping and electrical connections. Minimum Clearances to Combustibles Top Front 0 0 AL, CL AL= Alcove CL= Closet Rear 0 Left 0 Right 0 Mounting the Indoor Unit The indoor unit can be wall-mounted on a concrete wall. Note: The enclosed screws and rawl plugs are only suitable for concrete. For other construction materials, use bolts and anchors that are suitable for 100 lb. (46 kg) loads. 2. 3. 4. 1 (406 in. 6m m) 1. Installation of mounting bracket on brick/concrete wall: 1. Mark out the rawl plug holes. 2. Drill holes ne in. (n10 mm) and insert the rawl plugs supplied. 3. Fit the wall mounting bracket with the screws supplied. 4. Mount the indoor unit on the wall mounting bracket. Ensure that both tabs have locked into the indoor unit. Note: Check the condition of the wall where the indoor unit is to be installed. For the suitability of the supplied rawl plugs for various building materials, see the manufacturer’s instructions. For other construction materials, use fixing materials with sufficient load bearing capacity. Whichever mounting method is used, ensure that the bracket is tightly and securely fastened to wall. Failure to secure indoor unit properly could cause indoor unit to loosen, posing a severe safety hazard. 16 6221389 - 02 1 CAUTION Vitocal 100-AW AM2V Installation, Service and Operating Indoor Unit Installation Accessing the Indoor Unit Accessing the Indoor Unit for Installation 1. Remove the two door retaining screws. 2. Swing the door open to the right. Note: If required the mid jacketing panel can be removed to offer addition clearance for installation, refer to “Preparing for Service” on page 66 for instructions on removing the mid panel. 2. 6221389 - 02 1. 17 Indoor Unit Installation Vitocal 100-AW AM2V Installation, Service and Operating Piping Connections 2 imperfect threads Use moderate amount of dope Leave 2 threads bare Proper piping practice Support piping by proper suspension method. Piping must not rest on or be supported by indoor unit. Connections on the heating water and DHW sides If the connections have not been fitted previously, make the connections on the heating water and DHW sides. Note: If no tank is connected, close off the DHW tank supply connection with a cap. Heating water connections 1. Thoroughly flush heating system (particularly before connecting the heat pump to an existing system). 2. Connect indoor unit to the heating system. Note: Use an approved pipe sealant or Teflon tape when connecting the installation fittings. Maximum allowable working pressure (MAWP): 30 psig (2 bar) 1 WARNING Exposing the Vitocal to pressures and temperatures in excess of those listed will result in damages, and will render warranty null and void. Legend A DHW tank heating return B Heating system return C Supply from the heat pump outdoor unit D Return to the heat pump outdoor unit E Heating system supply F DHW tank heating supply Note: All fittings shown are field supplied Note: Install temperature gauge (field supplied) anywhere in the supply piping near the indoor (not shown). 18 SUPPORT ALL PIPING USING HANGERS. DO NOT support piping by the indoor unit or its components. HHUse isolation valves to isolate system components. General A distance of 2 in. (50 mm) from uninsulated hot water pipes to combustible components must be maintained. If the pipes are provided with a suitable pipe insulation of sufficient thickness and insulation, the distance mentioned above is not necessary (see also local regulations). 6221389 - 02 D E A B FC HHUse a two-hand wrench method when tightening fittings or piping onto the indoor unit connectors. Use one wrench to prevent the indoor unit pipes from twisting and the second wrench to tighten the fitting or piping. Failure to support the indoor unit connection could damage the heat pump and its internal piping. HHAll plumbing must meet or exceed all local state and national plumbing codes. Vitocal 100-AW AM2V Installation, Service and Operating Indoor Unit Installation Domestic Hot Water The Vitocal-AW AM2V series can be used in conjunction with the stand-alone DHW storage tanks offered by Viessmann. For the connection of a stand-alone DHW tank, installation fittings (field supplied), and a DHW temperature sensor (supplied with heat pump) is required. Size and select the DHW storage tank based on the forecasted DHW consumption of the building in question. For further technical information on DHW storage tanks, see the Vitocell Technical Data Manuals. If no domestic hot water tank is being connected to the indoor unit, the domestic hot water tank port needs to be capped. DHW storage tank information The DHW sensor is required when using a standalone DHW storage tank with the heat pump. The heat pump is supplied with a DHW sensor (all other fittings are field supplied). Making the DHW connections 1. With a Vitocell tanks, locate the DHW temperature sensor well and install the DHW temperature sensor using the installation instructions provided with the DHW storage tanks. 1 IMPORTANT Follow the Installation Instructions supplied with the Viessmann DHW storage tank when mounting and securing DHW tank temperature sensor. 6221389 - 02 1 WARNING If a DHW storage tank other than a Viessmann Vitocell tank is used, the installer must verify proper operation of the Viessmann DHW tank temperature sensor with original manufacturer of the tank. Viessmann strongly recommends the installation of a temperature tempering valve in the DHW supply line. 19 Indoor Unit Installation Vitocal 100-AW AM2V Installation, Service and Operating Safety Valve Installing the pressure relief valve: 1. Use the supplied fittings to install the pressure relief valve on the Supply from Outdoor Unit Connection of the Indoor Unit refer to “Piping Connections” on page 18. Minimum connection diameters: Pressure relief valve������������������������������������� c in. Discharge pipe�������������������������������������������� c in. Maximum operating pressure: 30 PSI (2 bar) Minimum operating pressure: 8 PSI (0.5 bar) F E D A C B Legend A Supply from Outdoor Unit B 1-a X 1 X 1 Inch Brass Reducing Tee C 1 X 6 Inch Long Brass Nipple D 1 X c Inch Brass Reducing Elbow E c Inch Brass Close Nipple F 30 PSI Pressure Relief Valve Installing the discharge pipe: 1. Install discharge pipe on pressure relief valve in such a way that... - the end of the pipe is not threaded. - the pressure relief discharge pipe extends to a floor drain and ends approximately 6 in. (150 mm) above the drain. Ensure that... - there is no shutoff valve installed in the discharge pipe. - discharge pipe diameter is not reduced. - discharge is not piped to outdoors. 1 IMPORTANT Install the (approved) factory supplied pressure relief valve. Removal of air from the system must occur via use of air vent(s) in the system supply. To ensure the heat pump can be purged of all air, ensure supply/return water lines do not contain restrictive piping where air could be trapped. 1 WARNING 6221389 - 02 Do not install an isolation valve between heat pump and pressure relief valve. The discharge pipe for the pressure relief valve must be oriented to prevent scalding of attendants. Pipe pressure relief valve discharge pipe close to floor drain. Never pipe discharge pipe to the outdoors. 20 Vitocal 100-AW AM2V Installation, Service and Operating Indoor Unit Installation Installation Fittings Installation Fittings The indoor unit is supplied with the installation fittings described. F E D I A C J B G G H H 6221389 - 02 Legend A Supply from Outdoor Unit B 1-a X 1 X 1 Inch Brass Reducing Tee C 1 X 6 Inch Long Brass Nipple D 1 X c Inch Brass Reducing Elbow E c Inch Brass Close Nipple F 30 PSI Pressure Relief Valve G 1 Inch Brass Close Nipple H Drain/Fill/Isolate Ball Valve I Return to Outdoor Unit J 1-a X 1 Inch Brass Reducing Coupling 21 Indoor Unit Installation Vitocal 100-AW AM2V Installation, Service and Operating Electrical Connections A B C D E F H OUT G N I J K L Legend: Note: -120VAC outputs rated current 2FLA -Maximum output 5FLA shared between all 120V outputs. 22 6221389 - 02 A DHW Recirculation Pump (PHWC) B Glycol Circuit Pump (PGC) C Cooling/Heating Divertering Valve/Pump (VCH) D Heating Circuit 1 Pump (PHC1) E Heating Circuit 2 Pump (PHC2) F Heating Circuit 2 Mixing Valve (VMCH2) G MODBus Communication with ODU (EU) H Heating Circuit 2 Temperature Sensor (THC2) I Heating Circuit 1 Temperature Sensor (THC1) J DHW Tank Temperature Sensor (TCYL) K Room Temperature Sensor (TR) L Outdoor Temperature Sensor (TO) M Backup Heat Activation - Dry Contact (OUT) Vitocal 100-AW AM2V Installation, Service and Operating Indoor Unit Installation Power Supply Indoor Unit AM2V 020028/034043 Power Supply G L2 L1 N A 230 VAC-1Ph-60Hz AM2V 051078 Power Supply 230 VAC-1Ph-60Hz 1 WARNING Incorrectly executed electrical installations can lead to injuries from electrical current and result in appliance damage. 1 WARNING The control must be grounded. Ensure that ‘L1’, ‘L2’, ‘N’ and ‘G’ are not interchanged. 1 IMPORTANT Legend 6221389 - 02 A 230V/1Ph/60Hz Power Supply Connection Electrical installations must comply with the latest edition of: HHIn the U.S.A., the National Electrical Code (NEC), ANSI/NFPA 70 and any other state, local codes and/or regulations. HHIn Canada, the Canadian Electrical Code (CEC), CSA C22.1 Part 1 and any other province, territory, local codes and/or regulations. 23 Outdoor Unit Installation Vitocal 100-AW AM2V Installation, Service and Operating Dimensions AM2V 020028/034043 Outdoor Unit A B C AM2V 034043 50-c (1285) 36-b (928) 18-d (460) 18-b (470) 20 (500) 38-e (975) 8-f (220) 14-d (360) 4-f (118) Legend A - Electrical Connections B - Heat Pump Hydronic Supply (1 in. NPT Male) C - Heat Pump Hydronic Return (1 in. NPT Male) 6221389 - 02 Dimensions in. (mm) AM2V 020028 A 46 (1165) B 31-a (795) C 15-c (400) D 17 (428) E 17-c (450) F 32-f (830) G 9-d (232) H 13 (330) I 6-b (166) 24 Outdoor Unit Installation Vitocal 100-AW AM2V Installation, Service and Operating Dimensions AM2V 051078 Outdoor Unit J A B C F G H I J 31-b (800) 6-d (155) 37-c (983) 8-b (215) 10 (252) 6221389 - 02 Dimensions in. (mm) A 49-a (1250) B 52-e (1329) C 19-b (495) D 20-a (515) E 21-a (540) Legend A - Electrical Connections B - Heat Pump Hydronic Supply (1 in. NPT Male) C - Heat Pump Hydronic Return (1 in. NPT Male) 25 Outdoor Unit Installation Vitocal 100-AW AM2V Installation, Service and Operating Recommended Minimum Service Clearances AM2V 020028/034043 Outdoor Unit b b B d c a b A A B a AM2V 020028/034043 Outdoor Unit 59 (1500) 20 (500) 39 (1000) 20 (500) 6221389 - 02 Legend A - Air outlet B - Air inlet Dimensions in. (mm) a b c d 26 Outdoor Unit Installation Vitocal 100-AW AM2V Installation, Service and Operating Recommended Minimum Service Clearances AM2V 051078 Outdoor Unit b b B a d c b A B A a AM2V 051078 Outdoor Unit 59 (1500) 20 (500) 39 (1000) 20 (500) 6221389 - 02 Legend A - Air outlet B - Air inlet Dimensions in. (mm) a b c d 27 Outdoor Unit Installation Vitocal 100-AW AM2V Installation, Service and Operating Outdoor Unit Sound Pressure Distance from the noise source ft (m) Power level acoustic Lw [dB (A)] Directivity Factor Q 3.3 (1) AM2V 020028 60 2 52 46 42 40 38 36 34 32 30 28 4 55 49 45 43 41 39 37 35 33 32 8 58 52 48 46 44 42 40 38 36 35 AM2V 034043 63 2 55 49 45 43 41 39 37 35 33 31 4 58 52 48 46 44 42 40 38 36 35 8 61 55 51 49 47 45 43 41 39 38 2 56 50 46 44 42 40 38 36 34 32 4 59 53 49 47 45 43 41 39 37 36 8 62 56 52 50 48 46 44 42 40 39 Outdoor Unit AM2V 051078 64 6.6 (2) 9.8 (3) 13.1 16.4 19.7 26.2 32.8 39.4 49.2 (4) (5) (6) (8) (10) (12) (15) Sound pressure level [dB (A)] Q = 2: freestanding heat pump on the outside of the building. Q = 4: heat pump on the building’s wall. 6221389 - 02 Q = 8: heat pump on the building’s wall situated in the corner 28 Vitocal 100-AW AM2V Installation, Service and Operating Outdoor Unit Installation Prior to Installation Mounting: HHMount the outdoor module in a free-standing position on a fixed supporting structure. HHIn areas with snowfall, ensure the outdoor unit has been installed using a snow stand or wall mounting bracket that will elevate the outdoor unit above the anticipated snow load. HHThe weight of the outdoor unit must be taken into account: see “Outdoor Unit Technical Data” on page 89. Setting: HHDo not install the exhaust side upwind. HHCarry out wall ducts and protective conduits for plumbing and electrical connection lines without using bent pipes and without changing the direction of the lines. Impact of weather conditions: HHWhen installing in areas exposed to wind, pay attention to wind loads. When the outdoor unit is mounted on a flat roof, significant wind loads may arise depending on the wind load zone and the height of the building. Include the outdoor unit in the lightning protection system. HHWhen designing rain protection or canopy, pay attention to the heat input (heating mode) and heat output (cooling mode) of the unit. Condensate: HHEnsure free drainage of the condensate away from the outdoor unit. Damping of sound and vibration between the building and the outdoor unit: HHMake the hydronic connection to the outdoor unit using flexible connections. HHElectrical cables should be installed without tension. 1 IMPORTANT 6221389 - 02 Strong impacts may lead to a damage to the jacketing of the unit. Do not press against the outdoor unit jacketing. 1 IMPORTANT Tilting the outdoor module sharply may lead to the oil from the compressor entering the refrigeration circuit and to a consequent failure during the startup. Maximum tilt angle: 45° for approximately 4 min., otherwise 30° Placement of the outdoor unit: HHSelect a location with good air circulation so that cooled air can flow out and warm air can flow in. HHDo not install in corners, recesses or between walls. This may lead to a recirculation of exhaust air. 1 IMPORTANT Restricting the free flow of air may lead to cooled air (or heated in the cooling mode) being drawn back in and lead to disruptions in the operation of the unit, a loss of efficiency and a consequent increase in electrical consumption. HHIf set up in an area exposed to strong winds, prevent the wind from affecting the fan area. Strong winds may disrupt the air flow through the evaporator. HHSelect the installation location so that the evaporator is not clogged by leaves, snow, etc. HHConsider sound propagation and reflection when selecting the mounting location. Design guidelines HHDo not mount the device under windows or next to bedroom windows. HHDo not install the device in basement sumps or depressions in the ground. HHMaintain a min. 10 ft. (3 m) distance from basement sumps and windows. HHMaintain a distance from terraces, gutters or surfaces with a protective coating of min. 10 ft. (3 m). At outdoor temperatures below 50°F (10°C), cooled air blown out causes a risk of icing. HHAvoid “short circulating” of air streams with ventilation equipment. Maintain a min. 10 ft. (3 m) distance from the intake area of ventilation units. HHThe installation location must be easily accessible, e.g. for service work 29 Outdoor Unit Installation Vitocal 100-AW AM2V Installation, Service and Operating Mounting on a Concrete Pad A A A A Concrete Pad Mounting 1. A concrete pad cast in place or a single piece pre-cast concrete or composite slab may be used. Select the size of the pad based on the dimensions provided 2. Center the outdoor unit on the pad 3. Place the rubber vibration isolators provided under the mounting feet. 4. Anchor the unit to the concrete pad. Legend A - Outdoor Unit B - Concrete anchor bolt C - Rubber vibration isolator D - Concrete pad Note: Ensure that the condensate drains freely. B Dimensions in. (mm) A B 2 (50) 4 (100) A B C 6221389 - 02 D 30 Vitocal 100-AW AM2V Installation, Service and Operating Outdoor Unit Installation Mounting using a Mounting Curb Curb Mounting 1. Slide two mounting bolts into each channel. 2. Align the mounting screws with the retaining tabs on the outdoor unit, place the outdoor unit over the bolts and secure in place. Legend A - Curb mounting bracket B - Gravel bed to facilitate condensate absorption C - Concrete foundation (if required) 2. Note: Ensure that the condensate drains freely. A 1. B 6221389 - 02 C 31 Outdoor Unit Installation Vitocal 100-AW AM2V Installation, Service and Operating Mounting on Stand Stand Mounting A 1. Assemble and secure stand (field supplied), ensure that spacing aligns with mounting feet of the outdoor unit. 2. Secure outdoor unit to the stand. Legend A - Outdoor Unit B - Mounting Stand B Note: Ensure that the condensate drains freely. 1 IMPORTANT Ensure that the stand or wall mount bracket is rated to support the weight of the outdoor unit. Follow the manufactures instructions for assembly and mounting requirements. A 6221389 - 02 B 32 Vitocal 100-AW AM2V Installation, Service and Operating Connections Safety Valve A D C B A E F G I H Legend A Supply from Outdoor Unit B 1 Inch Brass 90 Degree Elbow C 1 X 8 Inch Long Brass Nipple D Microbubble Air Separator E 1 X 1 X c Inch Brass Reducing Tee F c Inch Brass 90 Degree Street Elbow G c Inch Brass Close Nipple H 30 PSI Pressure Relief Valve I Return to Outdoor Unit Installing the pressure relief valve: 1 WARNING Installing the discharge pipe: 1. Install discharge pipe on pressure relief valve in such a way that... - the end of the pipe is not threaded. - the pressure relief discharge pipe approximately 6 in. (150 mm) above the ground. Ensure that... - there is no shutoff valve installed in the discharge pipe. - discharge pipe diameter is not reduced. Do not install an isolation valve between heat pump and pressure relief valve. The discharge pipe for the pressure relief valve must be oriented to prevent scalding of attendants. Pipe pressure relief valve discharge pipe close to floor drain. Never pipe discharge pipe to the outdoors. 6221389 - 02 1 IMPORTANT Install the (approved) factory supplied pressure relief valve. Removal of air from the system must occur via use of air vent(s) in the system supply. To ensure the heat pump can be purged of all air, ensure supply/return water lines do not contain restrictive piping where air could be trapped. 1. Use the supplied fittings to install the pressure relief valve on the Supply from Outdoor Unit. Minimum connection diameters: Pressure relief valve������������������������������������� c in. Discharge pipe�������������������������������������������� c in. Maximum operating pressure: 30 PSI (2 bar) Minimum operating pressure: 8 PSI (0.5 bar) 33 Connections Vitocal 100-AW AM2V Installation, Service and Operating Piping Connections Connection between Indoor and Outdoor Unit 6221389 - 02 This is a simplified schematic of the connection points between the Indoor Unit and the Outdoor Unit, and does not represent all the required components. 34 Vitocal 100-AW AM2V Installation, Service and Operating Connections Accessing the Outdoor Unit Accessing the Outdoor Unit 1. Remove the two access panel retaining screws and set aside. 2. Slide the access panel down and pull out to remove. 2. 1. Connection Overview A - Outdoor unit electrical connections board B - Grommet for low voltage connections C - 3/4 Inch knockout for power supply A 6221389 - 02 B C 35 Vitocal 100-AW AM2V Installation, Service and Operating Power Supply Outdoor Unit Power Supply 240 VAC-1Ph-60Hz L1, L2, G Power Supply Requirements AM2V 020028 208/230V-1Ph-60Hz Maximum 25 Amp Breaker AM2V 034043 208/230V-1Ph-60Hz Maximum 45 Amp Breaker AM2V 051078 208/230V-1Ph-60Hz Maximum 70 Amp Breaker 1 WARNING Incorrectly executed electrical installations can lead to injuries from electrical current and result in appliance damage. 1 WARNING The control must be grounded. Ensure that ‘L1’, ‘L2’, ‘N’ and ‘G’ are not interchanged. 1 IMPORTANT 6221389 - 02 Electrical installations must comply with the latest edition of: HHIn the U.S.A., the National Electrical Code (NEC), ANSI/NFPA 70 and any other state, local codes and/or regulations. HHIn Canada, the Canadian Electrical Code (CEC), CSA C22.1 Part 1 and any other province, territory, local codes and/or regulations. 36 Vitocal 100-AW AM2V Installation, Service and Operating Communication A Communication A - End of Line Resistor The indoor unit communicates with the outdoor unit through Modbus protocol. Using a two wire twisted pair, shielded 22 AWG cable connect the following terminals; Indoor Unit terminal EU ‘A’ to Outdoor Unit DIN rail terminal 1. Indoor Unit terminal EU ‘B’ to Outdoor Unit DIN rail terminal 2. 6221389 - 02 Install the supplied end of line resistor A across terminals EU A and B with communnication wires to the outdoor unit. 37 Installation Examples Vitocal 100-AW AM2V Installation, Service and Operating Installation Examples Connection to the hydronic system The Vitocal 100-AW AM2V series heat pump can operate in a closed-loop hydronic system (the minimum heating medium pressure is 8 PSI [0.5 bar]). The hydronic installation must be carried out in compliance with the applicable standards. The pipes connecting the heat pump to the indoor unit must have an internal diameter to ensure an adequate flow of the heating medium (see technical data table). Flexible piping must be used to connect the heat pump to the hydronic system to prevent the transmission of vibrations to the system. The heating medium pipes and connections must be thermally insulated. Do not switch off the unit when the outdoor air temperature is below freezing. This will protect the condenser of the outdoor unit from damage. If there is a risk of power failure, the heat pump heating circuit must be isolated from the hydronic module by means of an additional exchanger and the heat pump heating circuit must be filled with an antifreeze. A prerequisite for the warranty is an installation of a solids separator at the unit inlet. WARNING 1 If a DHW storage tank other than a Viessmann Vitocell tank is used, the installer must verify proper operation of the Viessmann DHW tank temperature sensor with the original manufacturer of the tank. Viessmann strongly recommends the installation of a temperature tempering valve in the DHW supply line. 1 IMPORTANT The examples on the following pages depict possible piping layouts of the Vitocal 100 AW heat pump equipped with Viessmann System Technology. For heat pump and tank combinations, please install only feasible combinations listed in the Viessmann Price List. Please note that the following examples are simplified conceptual drawings only! Piping and necessary componentry must be field verified. 1 IMPORTANT DHW supply and return piping between Vitocal DHW connections and the Viessmann DHW tank connections, shall be a minimum of 1b in. nominal pipe diameter connection outlet sizes provided on the Vitocal and the DHW tank). This will ensure the residual head of the field supplied pump is fully utilized to overcome the resistance of the DHW heat exchanger coil and to provide sufficient water flow to the Vitocal. In non-Viessmann DHW tank applications, perform, in addition to the above, accurate calculations for DHW tank coil pressure drop versus Vitocal internal pump residual head to ensure sufficient water flow to the Vitocal heat exchanger. Failure to heed the above instructions may inadequate DHW supply. 6221389 - 02 The hydronic installation must be made in such a way that the indoor unit can be operated in the heating circuit without the outdoor unit (according to the following installation diagrams). This will ensure the operation of the heating system in the event of a failure of the outdoor unit. Please note that in the following piping layout examples all pumps are field supplied. 38 Installation Examples Vitocal 100-AW AM2V Installation, Service and Operating System Example 1 Vitocal 100-AW AM2V with: - One direct-connected heating circuit - One heating circuit with a mixing valve - Combination System Buffer/DHW Storage Tank M O N S A P T Q U C L R J I B H K F D 6221389 - 02 E Legend: A Indoor Unit B Outdoor Unit C Outdoor Temperature Sensor D System Feed E Expansion Tank F Wye Strainer H DHW Temperature Sensor I Combination System Buffer/DHW Storage Tank J Temperature and Pressure Relief Valve K Potable Water Inlet L DHW Recirculation Pump M DHW Outlet N Room Temperature Sensor O Low Temperature Heating Circuit P Heating Circuit Temperature Sensor Q Heating Circuit Pump R Heating Circuit Mixing Valve S High Temperature Heating Circuit T Heating Circuit Temperature Sensor U Heating Circuit Pump 1 IMPORTANT System separation is required of underfloor heating systems employing non-oxygen diffusion barrier tubing. All components on the secondary side of the heat exchanger must be made of corrosionresistant materials. 39 Installation Examples Vitocal 100-AW AM2V Installation, Service and Operating System Example 2 Vitocal 100-AW AM2V with: - One direct-connected heating circuit - One heating circuit with a mixing valve - Vitocell System Buffer Tank - Vitocell DHW Storage Tank O N S M A C P T Q U R L J I B F V H K D E Q Heating Circuit Pump R Heating Circuit Mixing Valve S High Temperature Heating Circuit T Heating Circuit Temperature Sensor U Heating Circuit Pump V Vitocell MSCA 20USG (75L) Buffer Tank 1 IMPORTANT System separation is required of underfloor heating systems employing non-oxygen diffusion barrier tubing. All components on the secondary side of the heat exchanger must be made of corrosionresistant materials. 6221389 - 02 Legend: A Indoor Unit B Outdoor Unit C Outdoor Temperature Sensor D System Feed E Expansion Tank F Wye Strainer H DHW Temperature Sensor I DHW Storage Tank J Temperature and Pressure Relief Valve K Potable Water Inlet L DHW Recirculation Pump M DHW Outlet N Room Temperature Sensor O Low Temperature Heating Circuit P Heating Circuit Temperature Sensor 40 Installation Examples Vitocal 100-AW AM2V Installation, Service and Operating System Example 3 Vitocal 100-AW AM2V with: - One direct-connected heating circuit - One heating circuit with a mixing valve - One fan coil - Vitocell System Buffer Tank - Vitocell DHW Storage Tank O W N S M A C P T Q U R L J I B F V H K D E Q Heating Circuit Pump R Heating Circuit Mixing Valve S High Temperature Heating Circuit T Heating Circuit Temperature Sensor U Heating Circuit Pump V Vitocell MSCA 20USG (75L) Buffer Tank W Fan Coil 1 IMPORTANT System separation is required of underfloor heating systems employing non-oxygen diffusion barrier tubing. All components on the secondary side of the heat exchanger must be made of corrosionresistant materials. 6221389 - 02 Legend: A Indoor Unit B Outdoor Unit C Outdoor Temperature Sensor D System Feed E Expansion Tank F Wye Strainer H DHW Temperature Sensor I DHW Storage Tank J Temperature and Pressure Relief Valve K Potable Water Inlet L DHW Recirculation Pump M DHW Outlet N Room Temperature Sensor O Low Temperature Heating Circuit P Heating Circuit Temperature Sensor 41 Operating Vitocal 100-AW AM2V Installation, Service and Operating User Interface Use the mode selection dial C to set one of the modes: z + Winter (Space heating + DHW) A 9:37 Tu 04.02.2020 5,1° 24.2 ° Standby (Frost Protection Active) 55° B C Legend A - Display B - Navigation Dial C - Mode Selector Dial + Summer (Space Cooling + DHW) 9 Turning the navigation dial B (left or right), with the winter or summer mode being active, switches the function screens on the display A. To select the desired menu item press on the navigation dial B. HHHome Screen: indicates the basic parameters of the heat pump (see the table for details), HHDiagnostics Menu: allows the input and output signals of the heat pump to be viewed. HHSettings Menu: allows the heat pump parameters to be adjusted to the user’s preferences. HHService Menu: allows for heating system configuration to object’s conditions (available to the installer and service contractors though an access code) and preview of input and output heat pump’s signals and current parameters. HHTime Schedule Override: Allows the homeowner to override the active heating/cooling function without needing to adjust the time schedule Pressing and holding the navigation dial when in any menu will return you to the home screen. 6221389 - 02 The individual functions are accessed by selecting the relevant menu screen and pressing the navigation dial. If an error or warning in the system occurs, the home screen will display either a Eerr or 1. By pressing on dial B, a list of detected errors and warnings will be displayed. 42 Operating Vitocal 100-AW AM2V Installation, Service and Operating Display Symbols and Indications E G Indication of the running program m Disinfection of the storage tank 9:37 Tu 04.02.2020 5,1° C A 24.2 ° B D According to a pre-set daily/weekly schedule F Legend A - Signalling of heat take-up B - Heating Program ‘ON’ Indication C - Heater ‘ON’ Indication D - Compressor Operation Indicator E - Set Room Temperature F - Actual Room Temperature G - Outdoor Temperature H - DHW Tank Temperature 55° H Defrost cycle running PARTY - maintaining a comfortable temperature in the room and the cylinder HOLIDAYS - maintaining an economic or j frost-free temperature in the room and the storage tank Implementation of the frost protection program MANUAL - maintaining the desired h temperature in the room Indication of realized Room Temperature Signalling of heat take-up > central heating Signalling of heat take-up > hot tap water Cooling operation indication Other Symbols Eerr Error indication 1 Warning indication Indicates that the compressor is active. Flashing symbol indicates bivalent mode. Back-up Heating On 6221389 - 02 A Electric heat element is active 43 Operating Vitocal 100-AW AM2V Installation, Service and Operating Initial Start-up When first powering up the indoor unit, you will be prompted to select the operating language, and the model of connected outdoor unit. Language English 1. Scroll with the navigation dial to select the desired language and press the dial to select. 2. Scroll with the navigation dial to select the connected outdoor unit and press the dial to accept Espanol Francais Polski Type 020028 034043 051078 Diagnostics Menu This menu displays the current operating conditions of the heat pump indoor and outdoor units. Parameters displayed are based on the configuration of the system Settings Menu 9:37 Thu 22.04.2021 This menu provides access to the user adjustable settings of the heat pump. These settings include room temperature setpoint, DHW temperature setpoint, time schedules, etc. Available menu items may change depending on system configuration. 6221389 - 02 Settings 44 Vitocal 100-AW AM2V Installation, Service and Operating Operating Setting the Room Temperature There are four different programmable room temperature setpoints for heating, these are used when configuring the time schedule. The four temperature setpoints are: HHEconomy Temp. HHCom. Minus Temp. HHComfort Temp. HHCom. Plus Temp. The ‘Temporary Hold’ temperature setpoint uses the selected comfort temperature setting for space heating when the party mode is active. DHW Recirc. Sched. The ‘Holiday Override’ temperature setpoint uses the selected economy or frost protection temperature setting for space heating when the program is active. DHW Hygiene Settings Cooling Sched. The ‘Cooling’ temperature setpoint is for space cooling (only available with panel cooling). Scroll through the menu with the navigation dial and press the navigation dial to select. When complete select ‘End’ to return to the settings menu. Note: Frost protection ( ) in the standby and summer modes, if the room temperature falls below 45°F (7°C), the central heating circuit will be activated. A room temperature sensor is required to activate the function. Setting the DHW Temperature There are two different programmable DHW temperature setpoints for heating, these are used when configuring the time schedule. The two temperature setpoints are: HHEconomy Temp. HHComfort Temp. DHW Recirc. Sched. Scroll through the menu with the navigation dial and press the navigation dial to select. When complete select ‘End’ to return to the settings menu. DHW Hygiene Settings 6221389 - 02 Cooling Sched. 45 Operating Vitocal 100-AW AM2V Installation, Service and Operating Setting a Time Schedule The control allows for a maximum of 8 space heating time schedules, Sched. 1 through Sched. 8, which and be applied to each day of the week. Each of the 8 time schedules has five editable time frames, which can have different temperature setpoints. For space heating, there are four selectable room temperature setpoints ( , , , or ). The default setting of the space heating schedule is the economy temperature setpoint ( ). For DHW, there are two selectable DHW temperature setpoints ( , or ). The default setting and times between temperature setpoints of the DHW heating schedule is the economy temperature setpoint ( ). For DHW recirculation, only a start time and end time for DHW recirculation are programmable. For space cooling, only a start time and end time for space cooling are programmable. DHW Recirc. Sched. The ‘Weekly Sched.’ setting option assigns one of the eight daily time schedules to a selectable day of the week, each day of the week can have a different time schedule. DHW Hygiene Settings 6221389 - 02 Cooling Sched. 46 Vitocal 100-AW AM2V Installation, Service and Operating Operating Setting a Time Schedule Space Heating Time Schedule C D A Heating Sched. E F Sched. 1 1 6:00 - 9:15 B 2 15:20 - 22:15 Save Koniecand End Legend A - active time frame (max 5) B - no. of time frame according to schedule (max 5) C - starting time of the selected temperature D - finishing time of the selected temperature E - temperature selection ( , , , , or ) F - command (active when editing): HH R accept HH T delete HH add DHW Time Schedule C D DHW Sched. A E F Sched. 1 1 6:00 - 9:15 B 2 15:20 - 22:15 Save Koniecand End Legend A - active time frame (max 5) B - no. of time frame according to schedule (max 5) C - starting time of the selected temperature D - finishing time of the selected temperature E - temperature selection ( , or ) F - command (active when editing): In daily schedule the heating circuits have a defined starting time C and finishing time D of maintaining selected temperature value E in the room. Outside defined time frames economy temperature will be maintained in the room temperature. In buffer mode there is an automatic adjustment of start time C and finish time D which takes into consider the buffer tank charging time. In daily schedule the DHW heating has a defined starting time C and finishing time D of maintaining selected temperature value E in the room. Outside defined time frames economy temperature will be maintained in the reduced temperature. Adjusting the time schedule 1. Select chosen program number and press navigation dial. The first parameter flashes (start time). 2. Use the navigation dial to set the new time frame value (hour and minutes separately) by turning the dial, and confirm it by pressing the dial. 3. Repeat the process for finishing time. 4. Use the navigation dial to set the new temperature selection by turning the dial, and confirm it by pressing the dial. 5. Use the navigation dial to select the command column. To save changes select R command and press the dial to finish editing. To delete selected time frame select command T and press the dial. 6. To add new time frame, select last defined time frame and by pressing the dial go to command position, select command and press the dial to add new time frame (edition of new time frames described above). The entire day program is saved in the controller’s memory when you exit the day program by pressing the “Save and end” command. HH R accept HH T delete add 6221389 - 02 HH 47 Operating Vitocal 100-AW AM2V Installation, Service and Operating Setting a Time Schedule In daily schedule the DHW Recirculation a defined starting time B and finishing time C of operating the DHW recirculation pump. Outside defined time frames the DHW recirculation pump will not be active. DHW Recirculation Time Schedule AB C DHW Recirc. Sched. Sched. 1 2 18:30 - 23:00 In daily schedule the Space Cooling has a defined starting time B and finishing time C of Space Cooling. Outside defined time frames the Space Cooling will not be active. Koniec Adjusting the time schedule 1 6:00 - 8:00 Legend A - no. of time frame according to schedule (max 5) B - start time of recirculation pump operation C - finish time of recirculation pump operation HH R accept HH T delete Space Cooling Time Schedule AB C Cooling Sched. 1 6:00 - 8:00 Sched. 1 1. Select chosen program number and press navigation dial. The first parameter flashes (start time). 2. Use the navigation dial to set the new time frame value (hour and minutes separately) by turning the dial, and confirm it by pressing the dial. 3. Repeat the process for finishing time. 4. Use the navigation dial to set the new temperature selection by turning the dial, and confirm it by pressing the dial. 5. Use the navigation dial to select the command column. To save changes select R command and press the dial to finish editing. To delete selected time frame select command T and press the dial. The entire day program is saved in the controller’s memory when you exit the day program by pressing the “Save and end” command. 2 18:30 - 23:00 Koniec Legend A - active time frame (max. 5) B - cooling function start time C - cooling function completion time 6221389 - 02 HH R accept HH T delete 48 Vitocal 100-AW AM2V Installation, Service and Operating Operating DHW Tank Hygiene Function DHW Hygiene function is only available in systems with installed indirect DHW storage tanks. You can heat the water in the DHW tank to above 140°F (60°C) once a week or for an hour every day. This function is regularly carried out at the specified time. DHW Recirc. Sched. The following parameters can be set for operation of the tank cleansing function; DHW Hygiene Settings Run Sched. DHW Recirculation Cooling Sched. HHDay of the week: the day of the week (Monday Sunday) hygiene function operates HHStart time: Time of the selected day of the week the hygiene function will run. HHDuration: runtime of the hygiene function in minutes HHRun Sched.: Select ‘Yes’ to have the hygiene function run automatically on the select time and day of the week. Select ‘No’ for no hygiene function. HHDHW recirculation: DHW recirculation pump is active during hygiene function HHManual Operation: Manual start of hygiene function, which will terminate when the working time has expired. Scroll through the menu with the navigation dial and press the navigation dial to select. When complete select ‘End’ to return to the settings menu. WARNING 1 High DHW temperatures can cause scalding, e.g. if 6221389 - 02 the DHW temperature is above 140°F (60°C). Mix with cold water at the draw-off points. 49 Operating Vitocal 100-AW AM2V Installation, Service and Operating Setting Time and Date The following parameters can be set for time and date; DHW Recirc. Sched. DHW Hygiene Settings Cooling Sched. HHDate HHYear HHMonth HHDay HHTime Format HHHour HHMinute HHDaylight Savings: When set to ‘Yes’ Controller automatically switches over for daylight savings, when set to ‘No’ Controller does not automatically switched over for daylight savings Scroll through the menu with the navigation dial and press the navigation dial to select. When complete select ‘Save and End’ to return to the settings menu. Adjusting the Interface The following parameters can be set for the interface; DHW Recirc. Sched. DHW Hygiene Settings Cooling Sched. HHBrightness Min: setting of the brightness of the display in stand-by mode. HHBrightness Max: setting of the brightness of the display while interacting with the IDU. HHSound: When set to ‘Yes’ rotating the dials will generate a sound, when set to ‘No’ there is no sound generated when rotating the dials. HHDial Sensitivity: sets how fast or how slow the cursor will scroll through menu items. 6221389 - 02 Scroll through the menu with the navigation dial and press the navigation dial to select. When complete select ‘End’ to return to the settings menu. 50 Vitocal 100-AW AM2V Installation, Service and Operating Operating Setting the Language The following languages are available; DHW Recirc. Sched. DHW Hygiene Settings Cooling Sched. HHEnglish HHFrench (Canadian) HHSpanish HHPolish Scroll through the menu with the navigation dial and press the navigation dial to select. System Information The following system information can be displayed; DHW Recirc. Sched. DHW Hygiene Settings Cooling Sched. HHS.W. Ver. HMI: shows the software version of the IDU interface HHS.W. Ver. PCB: shows the software version of the control board HHControl Reboot IDU: Restart of the IDU HHFactory Settings: Restores the heatpump to factory settings 6221389 - 02 Scroll through the menu with the navigation dial and press the navigation dial to select. When complete select ‘End’ to return to the settings menu. 51 Operating Vitocal 100-AW AM2V Installation, Service and Operating Time Schedule Override 8:38 THU 14.04.2020 Time Schedule Override modes override the set time schedule for a selectable amount of time. Note: The symbol of the activated mode is indicated on the home screen. Refer to “Display Symbols and Indications” on page 43 for description of symbols. Time Schedule Overide Time Schedule Override Manual activation of extended operating conditions; HHTemporary Hold: setting the duration of the mode (from 1 to 24 hours or until cancelled). HHHoliday Override: setting the duration of the mode (from 1 to 60 days or until cancelled). HHManual Temp. Hold: room temperature setting implemented by the control system: until cancelled. Note: If any of the modes above is activated, it is possible to deactivate it after entering “Time Schedule Override”. 6221389 - 02 Scroll through the menu with the navigation dial and press the navigation dial to select. 52 Vitocal 100-AW AM2V Installation, Service and Operating Operating Service/Configuration Menu Changes in the configuration menu are possible after entering an access code. When prompted for an access code, turn the navigation dial to the required code and confirm the code by pressing the dial. If you want to exit from the code request screen, hold the navigation dial or wait until automatic return to main function screen. 9:37 Thu 22.04.2021 Code: 987 Service Control Strat. Scroll through the menu with the navigation dial and press the navigation dial to select. When complete select ‘End’ to return to the Service menu. Heating: Control Strat.: HHHeating Curve Operation - Temperature in is calculated on the basis of outside temperature and room temperature based on schedule. HHConstant Temperature - Supply temperature MAN, set individual for Circuit 1 and Circuit 2. Glycol Loop Heat Exchanger: HHYes - there is an additional heat exchanger in the system HHNo - there is no additional heat exchanger in the system. Frost protection: Room Temp. Offset Air Vent Mode 6221389 - 02 Measuring Unit HHYes - if the temperature in the building drops below 45LF (7LC) in the stand-by mode and the outside temperature is lower than 36LF (2LC), heating will be turned on , HHNo - protection is disabled. Electric Heater Delay: 53 Operating Vitocal 100-AW AM2V Installation, Service and Operating Service/Configuration Menu This parameter defines the time after which the heat pump activates the internal heater of the indoor unit if the set values parameters. The time is counted from the moment the setpoint temperature is reached. Warm Weather Shtdn: In case of if the outside temperature is above the bivalent point temperature, the back-up heat source will not be turned on. In case of need for an additional heat source, the condition for its activation is the activation of the immersion heaters Outside temp. offset: setting of selected temperature above which circuit will be switched off. TO Calibration: calibration of the displayed outside temperature value. Depending on the sign, the parameter is added to or subtracted from the measured values. Circuit 1 and Circuit 2: Parameters in this menu allow the user to adjust the operating conditions of the connected heating circuits. used and degree building insulation can be carried out, among others, by to generate high operating costs. HHRecirculation: Yes - activation of the Circuit 1, No - turning off the circuit. HHValve time (only available for Circuit 2): time needed to switch the valve by 90 degrees. Adjustment range from 60 to 480 seconds, factory default 120 seconds. During configuration, please check the set value with the value of the valve drive used. HHDynamics of regulation: the response speed of the valve drive to achieve the corresponding parameter in the Circuit 2. Cooling: HHOff: cooling function inactive, Fan coil, Radiant Cooling. For radiant and slab cooling a third party controller is required. HHChilled water setpoint: temperature of the chilled water HHHeating curve no.: Selection of a heating curve (see “Adjusting the Heating Curve” on page 58 to for instructions on adjusting the slope). Note: The parameter is present when the control is set according to heating curve (Adjust regulation type to: Acc. curve). HHCurve offset: Heating curve shift (see “Adjusting the Heating Curve” on page 58 to for instructions on adjusting the shift) Note The parameter is present when the control is set according to heating curve (Adjust regulation type to: Acc. curve). HHMIN supply temperature system: flow temperature when operating with constants parameters (manual setting of the heating medium) [Configuration -> Heating -> Regulation type: Fixed parameters], HHTemp. MAX: maximum supply temperature of the heating circuit. ATTENTION: setting too high temperatures, not suitable for building parameters, type of heating 54 DHW Tank: 6221389 - 02 Note: Heating circuit 1 is intended for heating connection to a high temperature circuit; Vitocal 100-AW AM2V Installation, Service and Operating Operating Service/Configuration Menu HHElectric Heater Delay: the parameter defines the time after which the heat pump is supported it will be an additional source of heat (immersion heater) if it does not reach the set value water temperature in the tank. Time is counted from the moment of reaching temperature of bivalent point HHRoom Temperature Sensor: room temperature control. HHIn case the outside temperature is above temperature of the bivalent point, the additional heat source will not remain included. If there is a need for an additional heat, the condition for its activation is the activation of the immersion heaters. No - room temperature control switched off. The room temperature reading does not affect the central heating operation. HHFrost protection: Yes - activation of the storage tank frost protection in stand-by mode, No - function inactive. HHDHW Tank: Yes - DHW tank circuit activation No- DHW tank inactive. The heat pump: HHBivalent point: the limiting outdoor temperature up to which the heat pump operates autonomously. Below this point, an additional heat source (heater) is activated HHShut-down temperature: the limit outdoor temperature at which the heat pump will shut down. If heating is required for central heating or hot tap water, the heater will be the only heat source. HHType: Model of the connected ODU. Yes - heating will be switched off once the set room temperature read by the room temperature sensor has been reached HHHysteresis: room temperature hysteresis when Room Control is activated HHRoom Temp. Offset: calibrates the value of the indicated room temperature. The parameter is added or subtracted from the value measured depending on the sign. DHW Recirculation: Yes - DHW recirculation pump control system enabled, No - DHW circulation pump system turned off. Pumps: HHPumps exercise: brief pump operation to prevent pump seizing HHAir vent mode: During the venting procedure (10 min) the heat pump in the hydraulic module runs alternately at maximum and minimum speed and the pumps the respective circuits are on. Thanks to this, concentration occurs air bubbles, which makes it easier to remove them from the installation. Off - system air purging turned off, Circuit 1 - Heating circuit 1 purging enabled, Circuit 2 - Heating circuit 2 purging enabled, 6221389 - 02 Communication: - Device ID: device number on the communication system. Room temperature: 55 Operating Vitocal 100-AW AM2V Installation, Service and Operating Service/Configuration Menu Heat Pump Module: This menu provides access to view heat pump operating conditions. When prompted for an access code, turn the navigation dial to the required code and confirm the code by pressing the dial. If you want to exit from the code request screen, hold the navigation dial or wait until automatic return to main function screen. Code: 65 Scroll through the menu with the navigation dial and press the navigation dial to select. When complete select ‘End’ to return to the Service menu. Parameters Address Description S12 Duration of defrost cycle S13 Entering temperature of defrost water S14 Defrost intervals S90 Minimum compressor frequency S91 Maximum compressor frequency S94 Vitocal Model Default Setting 10 minutes 13°C (55°F) 45 Minutes 30 Hz 90 Hz Dependant on model Settings Range 1-12 Minutes 0-30°C (32-86°F) 30-90 Minutes Do Not Adjust Do Not Adjust Do Not Adjust 6221389 - 02 The default settings of addresses S12, S13, and S14 ensure reliable and economical operation of the heat pump, however in areas of heavy snow fall addresses S12 and S13 can be increased and S14 decreased when standard defrost settings are determined to not be sufficient. 56 Vitocal 100-AW AM2V Installation, Service and Operating Operating Service/Configuration Menu Service: This menu accesses the actuator test function for the IDU. When prompted for an access code, turn the navigation dial to the required code and confirm the code by pressing the dial. If you want to exit from the code request screen, hold the navigation dial or wait until automatic return to main function screen. Code: 45 6221389 - 02 Scroll through the menu with the navigation dial and press the navigation dial to select. When complete select ‘End’ to return to the Service menu. 57 Operating Vitocal 100-AW AM2V Installation, Service and Operating Adjusting the Heating Curve Setting the Heating Curve Slope Adjusting the Slope The purpose of the heat pump controller is to maintain the temperature in the central heating system depending on the outdoor temperature. When the temperature outside the building is low, the need for heat is greater, whereas if the temperature outdoors is high, there is no need to maintain a high temperature in the system. The relationship between the outdoor temperature and the temperature of the central heating system can be represented in the form of a graph, the so-called heating curve. The figure shows a family of heating curves for a room temperature set point of 72°F (22°C). Depending on the characteristics of the building, the climate zone and the heating system type, a suitable curve needs to be selected. From the Circuit 1 and Circuit 2 configuration menus: 1. Use the navigation dial to select the desired heating circuit and press the dial to select. 2. Use the navigation dial to select ‘Use of Immersion Heaters’ and press the dial to select ‘Yes’ Supply Water Temperature F (C) 158 (70) 140 (60) 4 n=1 2 n=1 0 n=1 n=8 n=6 n=4 122 (50) 104 (40) 86 (30) 50 (10) 32 (0) Outdoor Temperature F(C) 14 (-10) -4 (-20) 6221389 - 02 68 (20) 68 (20) 58 Operating Vitocal 100-AW AM2V Installation, Service and Operating Adjusting the Heating Curve Setting the Heating Curve Shift Adjusting the Shift If the curve needs to be shifted, change the [curve shift] parameter. The figure shows as an example curve no. 8 with a shift of -14°F and 50°F (-10°C and 10°C). From the Circuit 1 and Circuit 2 configuration menus: 1. Use the navigation dial to select the desired heating circuit and press the dial to select. 2. Use the navigation dial to select ‘Use of Immersion Heaters’ and press the dial to select ‘Yes’ Supply Water Temperature F (C) 158 (70) 140 (60) 122 (50) 104 (40) 86 (30) 68 (20) 68 (20) =10 p n=8, =0 p n=8, -10 p= n=8, 50 (10) 32 (0) Outdoor Temperature F(C) 14 (-10) -4 (-20) 6221389 - 02 Tips on setting the heating curve Course of heating During cold seasons, it is too cold indoors. During cold seasons, the rooms are too warm. During transitional and cold seasons, it is too cold indoors. During transitional and cold seasons, the rooms are too warm. It is too cool indoors in transitional seasons, yet it is warm enough in cold seasons. It is too warm indoors in transitional seasons, yet warm enough in cold seasons. Actions concerning the “heating curve” Set the ‘slope’ to the next higher value. Set the ‘slope’ to the next lower value. Set the ‘level’ to a higher value. Set the ‘level’ to a lower value. Set the ‘slope’ to the next lower value and the ‘level’ to a higher value. Set the ‘slope’ to the next higher value and the ‘level’ to a lower value. 59 Service Vitocal 100-AW AM2V Installation, Service and Operating Troubleshooting Rooms are too cold Cause Corrective Action The heat pump is switched HHSwitch on the power switch off. HHSwitch on the main switch (if installed, outside the mechanical room). HHSwitch on the fuse in the electrical switchboard (the house fuse). The settings on the heat HHSpace heating/cooling must be activated. Check and correct the following pump controller have been settings if necessary: altered or are incorrect. HHWork programme HHHeating curve HHRoom temperature HHTime HHTime program for space heating/cooling HHRun additional electric heating for space heating, if necessary Heating of water in the HHWait until the water in the hot tap water exchanger has warmed up. hot tap water exchanger in HHIf necessary, reduce the hot water intake or, temporarily, the normal hot progress water temperature. The display shows HHRead out the type of notification. Confirm the notification. “Warning” or “Fault”. HHIf necessary, contact an Authorised Service Centre Rooms are too hot Cause The settings on the heat pump controller have been altered or are incorrect. The display shows “Warning” or “Fault”. Corrective Action Space heating/cooling must be activated. Check and correct the following settings if necessary: HHWork programme HHRoom temperature HHHeating curve/cooling temperature HHTime HHTime program for space heating/cooling HHActivate the “active cooling mode” if necessary HHRead out the type of notification. Confirm the notification. HHIf necessary, contact an Authorised Service Centre Cause Corrective Action The heat pump is switched HHSwitch on the power. off. HHSwitch on the main switch (if installed, outside the mechanical room). HHSwitch on the fuse in the electrical switchboard (the house fuse). The settings on the heat DHW heating must be started. Check and correct the following settings if pump controller have been necessary: altered or are incorrect. HHSpace heating or cooling time program HHDHW Temperature setpoint. HHDHW Time Program HHTime setting HHRun additional electric heating, if necessary, to heat DHW The display shows HHRead out the type of notification. “Warning” or “Fault”. HHIf necessary, contact an contact heating contractor. 60 6221389 - 02 No Domestic Hot Water Vitocal 100-AW AM2V Installation, Service and Operating Service Troubleshooting Domestic Hot Water is too hot Cause The settings on the heat pump controller have been altered or are incorrect. Warning Corrective Action Check and, if necessary, correct the DHW setpoint temperature. Cause Corrective Action Warning concerning If necessary, contact heating contractor. special occurrence, operating condition of heat pump, heating system Fault Corrective Action If necessary, contact heating contractor. 6221389 - 02 Cause Fault in heat pump or in heating system 61 Service Vitocal 100-AW AM2V Installation, Service and Operating Fault Codes Indoor Unit Fault Code Temp. HC2 Cooling temp. DHW Tank Temp. Room Temp. Outlet Temp. Inlet Temp. Press. Sensor Temp. HC1 Cause Circuit 2 temperature sensor error Cold buffer temperature sensor error DHW tank temperature sensor error Room temperature sensor error Flow temperature sensor error Return temperature sensor error Pressure sensor error IDU Circuit 1 temperature sensor error Outside Temp. Low Battery PIU Pump Heat Pump Module Low Pressure Communication Thermal Cut-off HP Inlet Temp. HP Outlet Temp. Curves Config. Error Circuit Config. Error HP Low Pressure Outside temperature sensor error Battery to be replaced Circulation pump error in indoor unit Heat pump error - outdoor unit Low pressure of the heating medium Communication error IDU - ODU Thermal switch triggered Inlet temperature sensor error - ODU Outlet temperature sensor error - ODU Heating curves configuration error Error in the configuration of the heating circuits PC low refrigerant pressure Fault Code E10 E11 E12 E13 E14 E15 E16 E17 E18 E19 E110 E111 E112 E113 E114 E115 E20 E21 62 Cause Reserved Reserved Heating return temp sensor failure Heating outlet water temp sensor failure High pressure protection Reserved Low pressure protection Reserved Water flow protection Electric heating overload protection Winter first class anti-freeze protection Winter second class anti-freeze protection Anti-freeze protection Reserved Room temp failure Reserved Exhaust temperature overprotection Reserved 6221389 - 02 Fault Codes Outdoor Unit Vitocal 100-AW AM2V Installation, Service and Operating Service 6221389 - 02 Fault Codes Outdoor Unit Fault Code E22 E23 E24 E25 E26 E27 E28 E29 E210 E211 E212 E213 E214 E215 E30 E31 E32 E33 E34 E35 E36 E37 E38 E39 E310 E311 E312 E313 E314 E315 E40 E41 E42 E43 E44 E45 E46 E47 E48 E49 E410 E411 Cause Reserved Fan 1 overload speed limit Fan 2 overload speed limit The temp difference of inlet water and outlet water over large protection Outlet water over heat Mixing outlet water temp sensor failure Hot water return temp sensor failure Hot water outlet water temp sensor failure Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved High pressure protection 3 times Reserved Low pressure protection 3 times Reserved Water flow protection 3 times Electric heating protection 3 times Reserved Reserved Anti-freeze protection 3 times Reserved Reserved Reserved Discharge over heat protection 3 times Reserved The temp difference of inlet water and outlet water temp over large 3 times The outlet water temp too lower 3 times Outlet water over temperature protection 3 times Reserved Reserved Reserved Reserved Reserved Reserved Reserved 63 Service Vitocal 100-AW AM2V Installation, Service and Operating Fault Code E412 E413 E414 E415 E50 E51 E52 E53 E54 E55 E56 E57 E58 E59 E510 E511 E512 E513 E514 E515 E60 E61 E62 E63 E64 E65 E66 E67 E68 E69 E610 E611 E612 E613 E614 E615 E70 E71 E72 E73 E74 E75 E76 64 Cause Reserved Reserved Reserved Reserved Inlet water temp failure Outlet water temp failure Coil temp failure Ambient temp failure Suction temp failure Anti- freeze temp failure The coil outlet water temp sensor failure Reserved Reserved EVI inlet temp failure EVI outlet temp failure Discharge temp failure Reserved System 1 pressure sensor failure Low ambient temp failure Outlet temp too low protection Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Hot water temp failure Reserved Reserved Fan 1 failure Fan 2 failure Communication failure(main board with fan motor module board) Reserved Communication failure(main board with fan motor 2 module board) IPM overheat Compressor start failure Compressor over currents Input voltage phase loss IPM current sampling fault Overheat protection of drive board devices Pre-charge failure 6221389 - 02 Fault Codes Outdoor Unit Vitocal 100-AW AM2V Installation, Service and Operating Service Fault Codes Outdoor Unit Cause DC bus bar over voltage DC bus under voltage AC input voltage under voltage AC input over current shutdown Input voltage sampling fault DSP and PFC communication failure Drive plate temperature fault DSP and communication board communication failure Mainboard communication failure IPM overheat stop Reserved Reserved 15VDC undervoltage Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Voltage electromechanical current down frequency alarm Compressor weak magnetic protection alarm Power unit overheating alarm Reserved AC input current down alarm EEPROM failure warning Reserved Reserved Reserved Reserved Reserved Reserved Reserved 6221389 - 02 Fault Code E77 E78 E79 E710 E711 E712 E713 E714 E715 E80 E81 E82 E83 E84 E85 E86 E87 E88 E89 E810 E811 E812 E813 E814 E815 E90 E91 E92 E93 E94 E95 E96 E97 E98 E99 E910 E911 E912 65 Service Vitocal 100-AW AM2V Installation, Service and Operating Preparing for Service Preparing for Service The mid panel of the jacketing can be remove to provide additional access of the internal components for service and maintenance. To remove the mid panel; 2. 1. 2. 3. 4. Remove the two door retaining screws. Swing the door open to the right. Remove the four mid panel retaining screws Slide the mid panel forward to remove 4. 1. When service has been completed reassemble in reverse order. 3. Check Sensors Sensors Resistance in k ohms All sensor connection are made to indoor unit, all sensors are NTC 10 kΩ. The temperature sensors are connected to a low-voltage printed circuit board. HHDHW Tank Temperature sensor HHSystem supply water temperature sensor HHRoom temperature sensors Temperature Temperature 66 6221389 - 02 Resistance in k ohms HHOutdoor temperature sensor Vitocal 100-AW AM2V Installation, Service and Operating Service Checking Fuses F3 Fuse F3 of the indoor unit is located on the main board of the indoor unit. Fuse type: - T 5.0 A H, 250 V~ 1. Switch off the power supply 2. Check the fuse, replace if necessary. 1 IMPORTANT Incorrect or improperly installed fuses may lead to an increased risk of fire. 1 IMPORTANT 6221389 - 02 Removing the fuses does not result in the load circuit being disconnected from voltage. Contact with any live parts may lead to electrocution. When working on the unit, it is essential that the load circuit is also disconnected. 67 Service Vitocal 100-AW AM2V Installation, Service and Operating Maintenance Cleaning Note: Commercially available cleaners and special cleaners for heat exchangers (evaporators) may cause damage to the heat pump. HHClean the surfaces of the unit with a damp cloth only. HHIf necessary, clean the shutters of the heat exchanger (evaporator) with a long bristle brush. Operating module of the heat pump controller The surface of the operating module can be cleaned with the microfibre cloth. Technical inspection and maintenance of the heating system. Regular maintenance ensures trouble-free, energy-efficient and environmentallyfriendly operation in the heating/cooling mode. For this purpose, it is best to contract a specialist company for inspection and maintenance. Damaged connection wires If the connection wires of the unit or of outdoor accessories are damaged, they must be replaced with specific connection cables. Only use the cables recommended by the manufacturer for replacement. Notify a specialist company for this purpose. Refrigerant The unit contains fluorinated greenhouse gases (a refrigerant) listed in the Kyoto Protocol. The refrigerant type which the device operates with is indicated on the rating plate. The Global Warming Potential (GWP) of the refrigerant is given as a multiple of the GWP of carbon dioxide (CO2). The GWP of carbon dioxide CO2 is 1. Refrigerant R32 Global Warming Potential GWP 675*1/677*2 According to the Fourth Assessment Report adopted by the Intergovernmental Panel on Climate Change (IPCC) *2 According to the Fifth Assessment Report adopted by the Intergovernmental Panel on Climate Change (IPCC) 6221389 - 02 *1 68 Vitocal 100-AW AM2V Installation, Service and Operating Service Maintenance 6221389 - 02 For systems with flammable refrigerants HHAnyone working on a refrigeration system is required to submit a proof of qualification issued by an accredited body authorised to issue industry certifications. The proof of qualification is a certificate of competence in the safe handling of refrigerants as prescribed in industry standards. HHMaintenance work must always be carried out in accordance with the manufacturer’s requirements. If assistance by other persons is required during maintenance and repair work, then a person trained in the safe handling of flammable refrigerants is required to supervise the work being carried out at all times. HHIn order to minimise the risk of fire, it is necessary to carry out safety checks before working on equipment where flammable refrigerants are used. Before working on a refrigeration circuit, the following measures must be taken: General: place of work HHInform the persons listed below of the work to be carried out: - All maintenance staff - All persons who are in the vicinity of the installation. HHClose off the area near the heat pump. HHCheck the surroundings of the heat pump for combustible materials and sources of ignition. Remove all combustible materials and sources of ignition. Monitoring the presence of refrigerant HHTo identify flammable atmosphere in good time: Before, during and after the work, check the surroundings for refrigerant leaks using an ignition-protected refrigerant detector designed for R32. The refrigerant detector must not cause any sparks and must be properly sealed. Fire extinguisher A CO2 or powder extinguisher must be available in the cases described below: HHFilling the system with refrigerant. HHPerforming welding or soldering work. Sources of ignition HHDuring any work carried out on a refrigeration circuit that contains or contained a refrigerant, ignition sources that could ignite the refrigerant must not be used. Any possible sources of ignition, including cigarettes, must be removed from the area where installation, repair, dismantling or disposal work is to be carried out that involves a hazard of the refrigerant leak. HHBefore starting work, check that there are no combustible materials or sources of ignition around the heat pump. Remove all combustible materials and sources of ignition. HHPlace no-smoking signs Work area ventilation HHCarry out repairs in the open air or ventilate the work area well before working on the cooling system or carrying out welding or soldering work. HHVentilation must be in operation at all times. The purpose of the ventilation is to dilute the refrigerant in the event of a leak and to discharge it outdoors if possible. 69 Service Vitocal 100-AW AM2V Installation, Service and Operating Inspection of the refrigeration installation HHReplaced electrical components must be suitable for the application and comply with the specifications provided by the manufacturer. Replace any defective components with original spare parts only. HHReplace components according to the recommendations issued by the company of Viessmann. Contact Viessmann technical service if necessary. HHCheck the surroundings of the heat pump for combustible materials and sources of ignition. Remove all combustible materials and sources of ignition. Carry out the following checks HHCheck the operation of the ventilation. Ventilation openings must not be blocked or obstructed. HHIf a system with hydronic decoupling is used, check the secondary circuit for the refrigerant. HHInscriptions and symbols must be clearly visible and legible. Replace any illegible inscriptions or symbols. HHRefrigerant lines or components must be fitted in such a way that they do not come into contact with corrosive substances. Exception: refrigerant lines are made of a corrosion-resistant material or are reliably protected against corrosion. Inspection of electric components HHWhen carrying out maintenance and repair work on eclectic parts, safety checks must be carried out: see below. HHIf a safety-critical fault occurs, do not connect the installation until the fault has been rectified. If it is not possible to rectify the fault immediately, a suitable interim solution for the operation of the installation must be found if possible. Notify the user of the installation Carry out the following safety checks: HHDischarging of capacitors: ensure that no sparks are generated during the discharge process. HHWhen filling or draining the refrigerant, as well as when flushing the refrigeration circuit, do not place any electrical parts or live wires near the device. HHCheck the earthing connection. Repairs to sealed casings HHDuring work on sealed components, the device must be powered off before the sealed cover is removed. HHTo warn of a potentially hazardous situation, a permanently operating refrigerant detector should be placed at critical locations. HHParticular care must be taken when working on electrical parts so as not to modify the casing in a way that weakens its protective effect. This applies to a damage to cables, the creation of too many connectors on one connection terminal, the creation of connectors that do not meet the manufacturer’s requirements, damage to seals and incorrect installation of cable restraints. HHEnsure that the unit is installed correctly. HHCheck that the seals are properly installed. Thereby, check that the seals reliably protect the device against the penetration of a flammable atmosphere. Replace any damaged hoses. ! Attention Silicone as a sealing agent may affect the performance of a leak detection devices. Do not use silicone as a sealing agent. HHSpare parts must comply with the manufacturer’s guidelines. HHWork on components that are suitable for flammable atmospheres: these components do not need to be powered off. 70 6221389 - 02 Maintenance Vitocal 100-AW AM2V Installation, Service and Operating Service Maintenance 6221389 - 02 Repairs to parts that operate in a combustible atmosphere HHUnless it can be established that the permissible voltage and current values will not be exceeded, no capacitive or inductive loads must be connected to the device. HHOnly those components that meet the requirements for operation in a flammable atmosphere may be connected to voltage in a flammable atmosphere. HHUse only original spare parts or parts approved by the Viessmann. In the event of a leak, all other parts may ignite the refrigerant. Wiring HHCheck that the wiring is not exposed to wear, corrosion, stretching, vibration or any adverse environmental conditions and that it is not located near sharp edges. HHWhen inspecting, also consider the effects of ageing and the effects of continuous vibration on the compressors and fans. Refrigerant detectors HHUnder no circumstances use ignition sources to detect the refrigerant and refrigerant leaks. HHNo flame detectors may be used to detect leaks. Leak detection The methods described below are suitable for detecting leaks in systems filled with a flammable refrigerant: Leak detection with electronic refrigerant detectors: HHElectronic leak detectors may not be adequately sensitive or need to be calibrated for a specific detection range. Calibrate the detector in a refrigerant-free environment. HHThe refrigerant detector must be suitable for detecting R32. HHThe refrigerant detector must contain no potential ignition sources. HHCalibrate the refrigerant detector for the refrigerant used. Set the trip threshold < 3 g/a, which is suitable for R32. Leak detection using leak detection fluids, Leak detection fluids are suitable for most of refrigerants. Note: Chlorine-containing leak detection fluids may react with the refrigerant. As a result, rust may form. Do not use any leak detection fluids that contain chlorine. Procedure when leaks are found in the refrigeration circuit: HHImmediately extinguish any fire in the vicinity of the heat pump. HHDo not solder leaks on the refrigeration circuit. Refrigerant suction and evacuation Perform the steps described in the “Refrigerant suction” section. Perform the steps described in the “Vacuum generation in refrigerant lines and indoor unit” section. Refrigerant filling Follow the steps described in the “Filling the refrigerant lines and indoor unit” section. Marking (inscriptions on the heat pump) A plate with the date and signature and the following information must be placed in a clearly visible position on the heat pump which has been decommissioned: HHFlammable refrigerant HHInstallation is not working. HHRefrigerant has been removed. 71 Wiring Vitocal 100-AW AM2V Installation, Service and Operating Indoor Unit Wiring Diagram AM2V 020028/034043 Indoor Unit F2 T5A > Legend E1 - Heating Box A1 - Main Board CP - Control Panel F1 - Fixed High Limit F2 - Automatic Reset High Limit CB1 - Circuit Breaker 72 K1 - Contactor M1 - Internal Diverting Valve M2 - Internal Circulation Pump Tin - Return Tempurature Sensor Tout - Flow Sensor P - Pressure Sensor 6221389 - 02 MCU Vitocal 100-AW AM2V Installation, Service and Operating Wiring Indoor Unit Wiring Diagram AM2V 051078 Outdoor Unit F2 T5A > 6221389 - 02 MCU Legend E1 - Heating Box A1 - Main Board CP - Control Panel F1 - Fixed High Limit F2 - Automatic Reset High Limit CB1 - Circuit Breaker K1 - Contactor M1 - Internal Diverting Valve M2 - Internal Circulation Pump Tin - Return Tempurature Sensor Tout - Flow Sensor P - Pressure Sensor 73 Wiring Vitocal 100-AW AM2V Installation, Service and Operating Outdoor Unit Wiring Diagram AM2V 020028 Outdoor Unit 74 Description Anti-freeze Temperature Ambient Temperature Compressor Coil Temperature Crankcase Heater EVI Inlet Gas Temperature EVI Outlet Gas Temperature Electronic Expansion Valve Electronic Expansion Valve for EVI Exhaust Temperature Fan Motor Flow Switch High Pressure Protection Inlet Water Temperature Relay of Circulation Pump Relay of Hot Water Pump Relay of 3-Way Valve Relay of Pan Heater Designation LP LPS OT OHP PH RT SUT SPS 4V TT Description Low Pressure Protection Low Pressure Sensor Outlet Water Temperature Overheat Protection Pan Heater Room Temperature Suction Temperature Switching Power Supply 4-Way Valve Tank Temperature 6221389 - 02 Designation AFT AT COMP CT CH EIT EOT EEV EVIV ET FM FS HP IT K4 K5 K9 K11 Wiring Vitocal 100-AW AM2V Installation, Service and Operating Outdoor Unit Wiring Diagram 6221389 - 02 AM2V 034043 Outdoor Unit Designation AFT AT COMP CT CH EIT EOT EEV EVIV ET FM FS HP IT K4 K5 K9 K11 Description Anti-freeze Temperature Ambient Temperature Compressor Coil Temperature Crankcase Heater EVI Inlet Gas Temperature EVI Outlet Gas Temperature Electronic Expansion Valve Electronic Expansion Valve for EVI Exhaust Temperature Fan Motor Flow Switch High Pressure Protection Inlet Water Temperature Relay of Circulation Pump Relay of Hot Water Pump Relay of 3-Way Valve Relay of Pan Heater Designation LP LPS OT OHP PH RT SUT SPS 4V TT Description Low Pressure Protection Low Pressure Sensor Outlet Water Temperature Overheat Protection Pan Heater Room Temperature Suction Temperature Switching Power Supply 4-Way Valve Tank Temperature 75 Wiring Vitocal 100-AW AM2V Installation, Service and Operating Outdoor Unit Wiring Diagram AM2V 051078 Outdoor Unit 76 Description Anti-freeze Temperature Ambient Temperature Compressor Coil Temperature Crankcase Heater EVI Inlet Gas Temperature EVI Outlet Gas Temperature Electronic Expansion Valve Electronic Expansion Valve for EVI Exhaust Temperature Fan Motor Flow Switch High Pressure Protection Inlet Water Temperature Relay of Circulation Pump Relay of Hot Water Pump Relay of 3-Way Valve Relay of Pan Heater Designation LP LPS OT OHP PH RT SUT SPS 4V TT Description Low Pressure Protection Low Pressure Sensor Outlet Water Temperature Overheat Protection Pan Heater Room Temperature Suction Temperature Switching Power Supply 4-Way Valve Tank Temperature 6221389 - 02 Designation AFT AT COMP CT CH EIT EOT EEV EVIV ET FM FS HP IT K4 K5 K9 K11 Vitocal 100-AW AM2V Installation, Service and Operating Parts Parts List Indoor Unit Model No. Serial No. AM2V 020028 7228973999999999 AM2V 034043 7228974999999999 AM2V 051078 7228975999999999 Ordering Replacement Parts: Please provide Model and Serial Number from rating plate when ordering replacement parts. Order replacement components from your Viessmann distributor. 0001 - Wall Mounting Bracket 0002 - Electrical Knockout Panel 0003 - Indoor Unit User Interface 0004 - Mid-panel 0005 - Door 0001 0002 0003 0004 6221389 - 02 0005 77 Parts Vitocal 100-AW AM2V Installation, Service and Operating Parts List Indoor Unit Model No. Serial No. AM2V 020028 7228973999999999 AM2V 034043 7228974999999999 AM2V 051078 7228975999999999 Ordering Replacement Parts: Please provide Model and Serial Number from rating plate when ordering replacement parts. Order replacement components from your Viessmann distributor. 0001 - DIN Rail 0002 - Fixed High Limit 0003 - Contactor 0004 - Control Board 0005 - Temperature Sensor 0001 0002 0003 0004 Other Items not Illustrated 0005 6221389 - 02 0006 - Immersion Temperature Sensor (System) 0007 - Strap-on Temperature Sensor System 0008 - Room Temperature Sensor 0009 - Outdoor Temperature Sensor 0010 - Fuse 5A 250VAC Time Delay 78 Parts Vitocal 100-AW AM2V Installation, Service and Operating Parts List Indoor Unit Model No. Serial No. AM2V 020028 7228973999999999 AM2V 034043 7228974999999999 AM2V 051078 7228975999999999 Ordering Replacement Parts: Please provide Model and Serial Number from rating plate when ordering replacement parts. Order replacement components from your Viessmann distributor. 0002 0015 0010 0003 0013 0012 0004 0014 0009 0006 0011 0005 0008 0007 6221389 - 02 0001 - Expansion vessel 0002 - Automatic Air Vent 0003 - Electric Heating Element 0004 - Gasket 0005 - DHW Heating Supply Pipe 0006 - Diverting Valve Body 0007 - System Supply Pipe 0008 - Diverting Valve Actuator 0009 - System Return Pipe 0010 - Pressure Sensor 0011 - Outdoor Unit Return Pipe 0012 - Manual Bleeder Screw 0013 - Circulation Pump 0014 - Outdoor Unit Supply Pipe 0015 - Auto Reset Temperature Limit 0001 79 Parts Vitocal 100-AW AM2V Installation, Service and Operating Parts List Outdoor Unit Model No. Serial No. AM2V 0200287986309999999999 Ordering Replacement Parts: Please provide Model and Serial Number from rating plate when ordering replacement parts. Order replacement components from your Viessmann distributor. 0011 0012 0013 0010 0014 0008 0009 0015 0016 0018 0017 0005 0020 0022 0023 0024 0021 0035 0037 0036 0041 0038 0040 0039 0042 0043 0019 0034 0025 0026 0027 0028 0033 0029 0030 0031 0032 6221389 - 02 0001 Fan Grill 0002 Front Panel 0003 Wind Deflector 0006 0004 Fan Blade 0007 0005 Fan Motor 0006 Left Panel 0007 Corner Panel 0004 0008 Air to Refrigerant Coil 0003 0009 Fan Motor Bracket 0002 0010 Electrical Box 0011 Top Panel 0001 0012 Top Rail 0013 Electrical Box Cover 0014 Rear Grill Panel 0015 Interior Separation Panel 0016 System Water Supply Pipe 0017 Refrigerant to System Water Plate Heat Exchanger 0018 System Water Return Pipe 0019 Reversing Valve 0020 System Water Flow Switch 0021 Electrical Grommet 0022 Rear Connection Panel 0023 Side Access Panel 0024 Support Bracket 0025 Low Pressure Switch 0026 High Pressure Switch 0027 Isolation Fill Valve 0028 One Way Safety Valve 0029 Electronic Expansion Valve 0030 Filter 0031 Electronic Expansion Valve 0032 Schrader Valve 0033 EVI Plate Heat Exchanger 0034 EVI Plate Heat Exchanger Bracket 0035 Refrigerant to System Water Plate Heat Exchanger Bracket 0036 Base Plate 0037 Compressor 0038 Transformer 0039 Compressor Cover 1 0040 Compressor Cover 2 0041 Transformer Housing 0042 Compressor Cover 3 0043 Compressor Cover 4 80 Parts Vitocal 100-AW AM2V Installation, Service and Operating Parts List Outdoor Unit Model No. Serial No. AM2V 0200287986309999999999 Ordering Replacement Parts: Please provide Model and Serial Number from rating plate when ordering replacement parts. Order replacement components from your Viessmann distributor. 0001 Fuse 0002 2 Pole Terminal 0003 Driver Board 0004 Switching Power Supply 0005 PC4003-G Board 0006 Electrical Enclosure 0007 Relay 0008 BHB21 Board 0009 DIN Rail 2 Pole 0010 Power Supply Terminal 0010 0008 0009 0007 0006 0005 0004 0003 0002 6221389 - 02 0001 81 Parts Vitocal 100-AW AM2V Installation, Service and Operating Parts List Outdoor Unit Model No. Serial No. AM2V 0340437986310999999999 Ordering Replacement Parts: Please provide Model and Serial Number from rating plate when ordering replacement parts. Order replacement components from your Viessmann distributor. 0011 0012 0013 0010 0014 0008 0009 0015 0016 0017 0020 0019 0005 0021 0038 0037 0041 0023 0024 0025 0022 0042 0040 0018 0039 0036 0043 0035 0026 0027 0028 0029 0030 0031 0032 0033 0034 6221389 - 02 0001 Fan Grill 0002 Front Panel 0003 Wind Deflector 0004 Fan Blade 0006 0005 Fan Motor 0007 0006 Left Panel 0007 Corner Panel 0008 Air to Refrigerant Coil 0009 Fan Motor Bracket 0004 0010 Electrical Box 0003 0011 Top Panel 0002 0012 Top Rail 0013 Electrical Box Cover 0001 0014 Rear Grill Panel 0015 Interior Separation Panel 0016 System Water Supply Pipe 0017 System Water Return Pipe 0018 Reversing Valve 0019 Refrigerant to System Water Plate Heat Exchanger Bracket 0020 Refrigerant to System Water Plate Heat Exchanger 0021 System Water Flow Switch 0022 Electrical Grommet 0023 Side Access Panel 0024 Rear Connections Panel 0025 Support Bracket 0026 Low Pressure Switch 0027 High Pressure Switch 0028 Schrader Valve 1 0029 Isolation Fill Valve 0030 One Way Safety Valve 0031 Electronic Expansion Valve 0032 Filter 0033 Electronic Expansion Valve 2 0034 Schrader Valve 2 0035 EVI Plate Heat Exchanger 0036 Fluid Reservoir 0037 Base Plate 0038 Compressor 0039 Compressor Cover 1 0040 Compressor Cover 2 0041 Transformer 0042 Compressor Cover 3 0043 Compressor Cover 4 82 Parts Vitocal 100-AW AM2V Installation, Service and Operating Parts List Outdoor Unit Model No. Serial No. AM2V 0340437986310999999999 Ordering Replacement Parts: Please provide Model and Serial Number from rating plate when ordering replacement parts. Order replacement components from your Viessmann distributor. 0001 Switching Power Supply 0002 Fan Speed Control Module 0003 Driver Board 0004 2 Pole Terminal 0005 PC4003-G Board 0006 Relay 0007 Fuse 0008 8 Pole Terminal 0009 BHB21 Board 0010 EMC Filter 0011 DIN Rail 2 Pole 0012 Power Supply Terminal 0011 0009 0008 0012 0010 0007 0006 0005 0004 0003 0002 6221389 - 02 0001 83 Parts Vitocal 100-AW AM2V Installation, Service and Operating Parts List Outdoor Unit Model No. AM2V 051078 Serial No. 7986311999999999 Ordering Replacement Parts: Please provide Model and Serial Number from rating plate when ordering replacement parts. Order replacement components from your Viessmann distributor. Large 0011 0012 0013 0010 0014 0006 0007 0008 0009 0016 0003 0017 0018 0004 0019 0021 0015 0022 0002 0005 0001 0044 0041 0020 0040 0046 0042 0037 0047 0048 84 0024 0025 0026 0023 0038 0039 0045 0028 0027 0029 0030 0043 0036 0031 0032 0033 0034 0035 6221389 - 02 0001 Fan Grill 0002 Front Panel 0003 Wind Deflector 0004 Fan Blade 0005 Fan Motor 0006 Left Panel 0007 Corner Panel 0008 Air to Refrigerant Coil 0009 Fan Motor Bracket 0010 Electrical Box 0011 Top Panel 0012 Top Rail 0013 Electrical Box Cover 0014 Rear Grill Panel 0015 Interior Separation Panel 0016 Refrigerant to System Water Plate Heat Exchanger 0017 System Water Supply Pipe 0018 System Water Return Pipe 0019 Refrigerant to System Water Plate Heat Exchanger Bracket 0020 Reversing Valve 0021 Transformer 0022 Schrader Valve 1 0023 Electrical Grommet 0024 Side Access Panel 0025 Rear Connections Panel 0026 Support Bracket 0027 Isolation Fill Valve 0028 High Pressure Switch 0029 Low Pressure Switch 0030 One Way Safety Valve 0031 Electronic Expansion Valve 0032 Filter 0033 Electronic Expansion Valve 0034 Schrader Valve 2 0035 Schrader Valve 3 0036 EVI Plate Heat Exchanger 0037 EVI Plate Heat Exchanger Bracket 0038 Bracket 0039 Compressor 0040 Compressor Cover 1 0041 Base Plate 0042 Compressor Cover 2 0043 Compressor Cover 3 0044 Compressor Cover 4 0045 Transformer 0046 Transformer Cover 0047 Transformer Base 0048 Mounting Bracket Parts Vitocal 100-AW AM2V Installation, Service and Operating Parts List Outdoor Unit Model No. Serial No. AM2V 0510787986311999999999 Ordering Replacement Parts: Please provide Model and Serial Number from rating plate when ordering replacement parts. Order replacement components from your Viessmann distributor. 0001 PC4003-G Board 0002 Switching Power Supply 0003 Fan Speed Control Module 0004 8 Pole Terminal 0005 Fuse 0006 Driver Board 0007 2 Pole Terminal 0008 Temperature Sensor 0009 Electrical Enclosure 0010 BHB21 Board 0011 EMC Filter 0012 Relay 0013 Power Supply Terminal 0014 DIN Rail 2 Pole 0014 0013 0012 0011 0010 0008 0009 0007 0006 0004 0005 0002 0003 6221389 - 02 0001 85 Parts Vitocal 100-AW AM2V Installation, Service and Operating Parts List Indoor Unit Model No. Serial No. AM2V 020028 7228973999999999 AM2V 034043 7228974999999999 AM2V 051078 7228975999999999 Ordering Replacement Parts: Please provide Model and Serial Number from rating plate when ordering replacement parts. Order replacement components from your Viessmann distributor. 0001 - Reducer 1-a to 1 in. Brass 0002 - 1 in. Close Nipple Brass 0003 - Isolation Valve 0004 - 1-a X 1 X 1 in. Reducing Tee Brass 0005 - Pressure Relief Valve 30 PSI 0006 - c in. Close Nipple Brass 0007 - 1 in. X 6 in. Long Nipple Brass 0008 - 1 to c in. Reducing Elbow Brass 0005 0001 0004 0002 0002 0006 0007 0008 0003 6221389 - 02 0003 86 Vitocal 100-AW AM2V Installation, Service and Operating Parts Parts List Outdoor Unit Model No. Serial No. AM2V 0200287986309999999999 AM2V 0340437986310999999999 AM2V 0510787986311999999999 Ordering Replacement Parts: Please provide Model and Serial Number from rating plate when ordering replacement parts. Order replacement components from your Viessmann distributor. 0001 - Pressure Relief Valve 30 PSI 0002 - c in. Close Nipple Brass 0003 - c in. Street Elbow Brass 0004 - 1 X 1 X c in. Reducing Tee Brass 0005 - Microbubble Air Separator 0006 - 1 in. Elbow Brass 0007 - 1 in. X 8 in. Long Nipple Brass 0006 0001 0002 0005 0007 0006 0003 6221389 - 02 0004 87 Technical Data Vitocal 100-AW AM2V Installation, Service and Operating Indoor Unit Technical Data Indoor Unit Electrical Data Power Supply Electric Heater Output Heating Elements Hydronic Data Hydronic connection Voltage Phase Hertz Amperage (FLA) Maximum Fuse (Amps) kW (BTU) AM2V 020028 AM2V 034043 AM2V 051078 230 VAC 1 60 31 230 VAC 1 60 31 230 VAC 1 60 43 40 40 50 6 (20500) 2 6 (20500) 2 9 (30700) 3 PSI (bar) PSI (bar) LF (LC) LF (LC) LF (LC) 1a NPT (Male Threads) 8 (0.5) 30 (2) 140 (60) 167 (75) 165 (74) 1a NPT (Male Threads) 8 (0.5) 30 (2) 140 (60) 167 (75) 165 (74) 1a NPT (Male Threads) 8 (0.5) 30 (2) 140 (60) 167 (75) 165 (74) LF (LC) USG (l) PSI (bar) 186 (86) 3.2 (12) 14 (1) 186 (86) 3.2 (12) 14 (1) 186 (86) 3.2 (12) 14 (1) GPM (m3/h) GPM (m3/h) ft. of hd (kPa) MBH 2.6 (0.6) 4.4 (1.0) 0.6 (2) 510 3.1 (0.7) 7.5 (1.7) 1.6 (5) 510 3.7 (0.85) 12.8 (2.9) 5.0 (15) 510 in. (mm) in. (mm) in. (mm) lbs (kg) 28-b (723) 16-a (416) 12-c (323) 64 (29) 28-b (723) 16-a (416) 12-c (323) 64 (29) 28-b (723) 16-a (416) 12-c (323) 64 (29) 6221389 - 02 Min. Operating Pressure Max. Operating Pressure Max. System Temperature Max. DHW Temperature Max. Operating Temperature Fixed High Limit Expansion vessel volume Expansion vessel precharge Minimum flow Maximum flow Pressure drop Minimum Relief Valve Capacity Dimensional Data Dimensions Height Width Depth Weight Model 88 Technical Data Vitocal 100-AW AM2V Installation, Service and Operating Outdoor Unit Technical Data Outdoor Unit Heating/Cooling Data Heating Capacity Cooling Capacity Range Model Low High Energy Efficiency Ratio (EER) COP Electrical Data Power Supply Total Electrical Load Compressor Load Rating Fan Motor Load Rating Minimum Circuit Ampacity Maximum Fuse Refrigerant Refrigerant Factory Charge Max. Allowable Pressure Heating Max. Allowable Pressure Cooling Max. Operating Pressure Low Side Max. Operating Pressure High Side Hydronic Data Hydronic connection Water Flow Rate Pressure drop Maximum temperature of heating medium Air and Noise Maximum DC power of fan Maximum air flow Minimum/maximum air temperature Maximum sound pressure level at 3.3 ft. (1m) distance Maximum sound power level Dimensional Data Dimensions (HXWXD) 20.5 (6.0) 1.4 (5.0) 1.5 (5.2) 16.81 4.927 34.0 (10.0) 2.8 (9.8) 3.0 (10.5) 16.75 4.909 58.0 (17.0) 4.2 (14.7) 4.3 (15.1) 14.46 4.238 Voltage Phase Hertz Amps Amps Amps Amps Amps 208/230 VAC 1 60 13.0 12.2 0.8 17 25 208/230 VAC 1 60 21.8 21.0 0.8 28 45 208/230 VAC 1 60 35.1 33.5 2 X 0.8 44 70 lbs (kg) PSIG (MPa) R32 2.43 (1.1) 725 (5.0) R32 3.97 (1.8) 740 (5.1) R32 4.41 (2.0) 972 (6.7) PSIG (MPa) 624 (4.3) 609 (4.2) 624 (4.3) PSIG (MPa) 305 (2.1) 305 (2.1) 305 (2.1) PSIG (MPa) 638 (4.4) 638 (4.4) 638 (4.4) GPM (m3/h) ft. of hd (kPa) LF(LC) 1 NPT (Male Threads) 3.7-8.8 (0.85-2.0) 3.3 (10) 149 (65) 1 NPT (Male Threads) 6.2-15.0 (1.4-3.4) 6.7 (20) 149 (65) 1 NPT (Male Threads) 11.4-25.5 (2.6-5.8) 15.0 (45) 149 (65) W CFM (m3/h) 85 1765 (3000) 170 2650 (4500) dB(A) -13/109 (-25/43) 52 -13/109 (-25/43) 55 2X75 2X1470 (2X2500) -13/109 (-25/43) 56 dB(A) 60 63 64 in. (mm) in. (mm) in. (mm) lbs (kg) 31-a (795) 46 (1165) 15-c (400) 198 (90) 36-b (928) 50-c (1285) 18-d (460) 291 (132) 52-e (1329) 49-a (1250) 19-b (495) 353 (160) 6221389 - 02 Weight MBH (kW) Tons (kW) Tons (kW) LF(LC) Height Width Depth AM2V 020028 AM2V 034043 AM2V 051078 89 Water Quality Vitocal 100-AW AM2V Installation, Service and Operating Filling the System Water quality Treatment for Vitocal 100 AW feed water should be considered in areas of known problems, such as where a high mineral content and hardness exist. In areas where freezing might occur, an antifreeze may be added to the system water to protect the system. Please adhere to the specifications given by the antifreeze manufacturer. Do not use automotive silicate based antifreeze. Please observe that an antifreeze/water mixture may require a backflow preventer within the automatic water feed and influence components such as diaphragm expansion tanks, radiation, etc. Maximum antifreeze content is 50% for the Vitocal 100 AW. Do not use sulphur-containing Vitocal feed water. Check pH-level after some operating time. It should be in the range from 8.2 to 9.5. If it is not, please take appropriate measures. Total permissible hardness of the fill and top-up water - 70 ppm. 6221389 - 02 Do not use antifreeze other than specifically made for hot water heating systems. System also may contain components which might be negatively affected by antifreeze. Check total system frequently when filled with antifreeze. Advise system operator/ultimate owner that system is filled with a glycol mix. The heating contractor must provide a SDS (Safety Data Sheet) for the antifreeze used to the system operator/ultimate owner. 90 6221389 - 02 Vitocal 100-AW AM2V Installation, Service and Operating 91 Printed on environmentally friendly F(recycled and recyclable) paper. Technical information subject to change without notice. Viessmann Manufacturing Company Inc. 750 McMurray Road Waterloo, Ontario · N2V 2G5 · Canada TechInfo Line 1-888-484-8643 1-800-387-7373 · Fax (519) 885-0887 www.viessmann.ca · [email protected] 6221389 - 02 Viessmann Manufacturing Company (U.S.) Inc. 45 Access Road Warwick, Rhode Island · 02886 · USA TechInfo Line 1-888-484-8643 1-800-288-0667 · Fax (401) 732-0590 www.viessmann-us.com · [email protected] ">
/
Preuzimanje
Samo prijateljski podsjetnik. Dokument možete pogledati ovdje. Ali što je najvažnije, naš AI ga je već pročitao. Može objasniti složene stvari jednostavnim riječima, odgovoriti na vaša pitanja na bilo kojem jeziku i pomoći vam da brzo navigirate čak i najdužim ili najkompliciranijim dokumentima.
Oglas