PC1864
Wiring Trikdis GT+ Cellular Communicator and
Programming the Panel
CAUTION • The communicator should be installed and maintained by qualified personnel.
• Prior to installation, it is advised to read full device installation manual carefully in order to
avoid mistakes that can lead to malfunction or even damage the equipment.
• Disconnect the power supply before making any electrical connections.
• Changes, modifications or repairs not authorized by the manufacturer shall void your rights
under the warranty.
Schematics for wiring the communicator
to the security control panel
Following the schematics provided below, wire the communicator to the control panel.
T-1 R-1 TIP RING EGND
Z8 COM Z7 Z6 COM Z5 Z4 COM Z3 Z2 COM Z1 4PGM 3 2PGM 1 GRN YEL BLK RED -BELL+
DSC PC1864
trikdis.com
- +
AUX
AC
PC1864
Wiring Trikdis GT+ Cellular Communicator and
Programming the Panel
DSC PC1864 panel do not need to be programmed.
LED indication of communicator operation
Indicator
Light status
NETWORK
Off
Yellow blinking
Green solid with yellow blinking
Off
Green solid
Green blinking
Off
Green solid
Yellow solid
Green solid and yellow blinking
No connection to cellular network
Connecting to cellular network
Communicator is connected to cellular network.
Yellow blinks count indicates signal strength, 10 blinks
max. Sufficient cellular signal strength for 4G network level 3 (three yellow flashes).
No unsent events
Unsent events are stored in buffer
(Configuration mode) Data is being transferred to/from
communicator
Power supply is off or disconnected
Power supply is on with sufficient voltage
Red blinking
Red solid
Power supply voltage is insufficient (≤11.5V)
Configuration mode) Communicator is ready for
configuration
(Configuration mode) No connection with computer
No operation problems
SIM card not found
SIM card PIN code problem (incorrect PIN code)
Programming problem (No APN)
Registration to GSM network problem
Registration to GPRS/UMTS network problem
No connection with the receiver
Lost connection with control panel
The entered ICCID number does not match the ICCID
number of the SIM card
(Configuration mode) Memory fault
(Configuration mode) Firmware is corrupted
1 green blink
None
2 green blinks
GSM
3 green blinks
GPRS
4 green blinks
EDGE
5 green blinks
HSDPA, HSUPA, HSPA+, WCDMA
6 green blinks
LTE TDD, LTE FDD
Yellow solid
Off
1 red blink
2 red blinks
3 red blinks
4 red blinks
5 red blinks
6 red blinks
7 red blinks
8 red blinks
trikdis.com
PC1864
Wiring Trikdis GT+ Cellular Communicator and
Programming the Panel
Setting up the GT+ communicator with the app
Download and launch the Protegus application or use the browser version: web.protegus.app.
The installer must connect to Protegus with an installer account.
Step 1
Step 2
Step 3
Step 4
Select security company
Press "DSC"
Station 1
Station 2
Click the "Add new system" Enter the IMEI number of
button
the communicator
Step 5
Step 6
Step 7
Step 8
Press "PC1864"
Enter "Object ID" and
"Module ID". Press "NEXT"
Wait while the
configuration is written
Press "Add to Protegus2"
trikdis.com
PC1864
Wiring Trikdis GT+ Cellular Communicator and
Programming the Panel
Setting up the GT+ communicator with the app
Step 9
Step 10
Step 11
Step 12
Enter system "Name".
Press "Next"
Press "Skip"
Press on system
Wait 1 minute and press
"Transfer"
Step 13
Step 14
After completing the setup and installation perform a
system check:
1. Create an event:
- by arming/disarming the system with the control
panel’s keypad;
- by triggering a zone alarm when the security
system is armed.
2. Make sure that the event arrives to the CMS
(Central Monitoring Station) and the Protegus app.
Enter the e-mail of the user
The system will appear in
to whom the installer will
Protegus on the user's
transfer the system. Press
phone
"Transfer"
trikdis.com
">