EDR-8010 Series
Quick Installation Guide
Moxa Industrial Secure Router
Version 1.1, August 2023
Technical Support Contact Information
www.moxa.com/support
2023 Moxa Inc. All rights reserved.
P/N: 1802080100011
*1802080100011*
https://manual-hub.com/
Package Checklist
The EDR-8010 Series secure router is shipped with the items listed
below. If any of these items are missing or damaged, please contact
your customer service representative for assistance.
•
•
•
•
•
1 Industrial secure router
1 USB-C-to-DB9 cable
Quick installation guide (printed)
Protective caps for unused ports
Warranty card
Features
Advanced Industrial Networking Capability
•
•
•
•
•
•
•
•
•
All-in-one firewall/NAT/VPN/router/switch with 8 FE + 2 Gigabit
ports
Visualize OT security with the MXsecurity management software
Secure remote access tunnel with VPN
Examine industrial protocol data with Deep Packet Inspection (DPI)
technology
Easy network setup with Network Address Translation (NAT)
RSTP/Turbo Ring for enhanced network redundancy
Security features based on IEC 62443/NERC CIP
Supports secure boot for checking system integrity
-40 to 75°C operating temperature range (-T model)
-2https://manual-hub.com/
Panel Views of EDR-8010 Series
EDR-8010 Series
Front Panel
Front Panel:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
USB port for ABC-02-USB
1G SFP port speed LED
indicator
1G SFP ports
1G SFP port speed LED
indicator
100 Mbps copper port speed
LED indicator
10 Mbps copper port speed
LED indicator
10/100 Mbps copper ports
Power input PWR1 LED
indicator
Power input PWR2 LED
indicator
STATE LED indicator
MSTR/H.TC LED indicator
CPLR/T.TC LED indicator
VRRP/HA LED indicator
VPN LED indicator
USB LED indicator
Reset button
Top Panel:
Top Panel
1.
2.
3.
4.
5.
6.
-3https://manual-hub.com/
Grounding screw
Terminal block with latch for
Power 2 input
Terminal block with latch for
Power 1 input
Terminal block with latch for
digital input
Terminal block with latch for
relay output
Type-C serial console port
Rear Panel
Rear Panel:
1.
-4https://manual-hub.com/
DIN-rail mounting kit
Mounting Dimensions
EDR-8010 Series
DIN-rail Mounting (DNV-certified)
In the package, the metal DIN-rail mounting kit is fixed to the back
panel of the EDR-8010 Series with four screws (M3 x 6 mm). Mount the
EDR-8010 Series on a corrosion-free mounting rail that adheres to the
EN 60715 standard.
-5https://manual-hub.com/
Suggested Installation Method
STEP 1:
Place the upper lip of the DIN-rail
kit onto the mounting rail.
STEP 2:
Press the EDR-8010 Series towards
the mounting rail until it snaps into
place.
Suggested Removal Method
STEP 1:
Pull down the latch on the DIN-rail
kit with a screwdriver.
STEPS 2 & 3:
Slightly pull the EDR-8010 Series
forward and lift it up to remove it
from the mounting rail.
Wall Mounting
For some applications, you will find it convenient to mount the EDR8010 Series on the wall, as shown in the following illustrations.
STEP 1: Remove the aluminum DIN-rail attachment plate from the rear
panel of the EDR-8010 Series, and then attach both the wall-mounting
plates with four screws (M3 x 5 mm).
-6https://manual-hub.com/
STEP 2: Mounting the EDR-8010 Series on the wall requires four
screws. Use the EDR-8010 Series with the wall mount plates attached
as a guide to mark the correct location of the four screws. The head of
the screws should be less than 7.0 mm in diameter, and the shaft
should be less than 3.5 mm in diameter.
Wiring Requirements
WARNING
Do not disconnect modules or wires unless power has been
switched off or the area is known to be non-hazardous. The
devices may only be connected to the supply voltage shown on
the type plate. The devices are designed for operation with a
Safety Extra-Low Voltage. Thus, they may only be connected to
the supply voltage connections and to the signal contact with
the Safety Extra-Low Voltages (SELV) in compliance with
IEC 60950-1/VDE 0805.
ATTENTION
This unit is a built-in type. When the unit is installed in another
piece of equipment, the equipment enclosing the unit must
comply with fire enclosure regulation UL/IEC 62368-1 (or
similar regulation).
-7https://manual-hub.com/
ATTENTION
Safety First!
Be sure to disconnect the power cord before installing and/or
wiring your EDR-8010 Series.
Calculate the maximum possible current in each power wire
and common wire. Observe all electrical codes dictating the
maximum current allowable for each wire size.
If the current goes above the maximum ratings, the wiring
could overheat, causing serious damage to your equipment.
Please read and follow these guidelines:
•
•
•
•
•
Use separate paths to route wiring for power and devices. If power
wiring and device wiring paths must cross, make sure the wires are
perpendicular at the intersection point.
NOTE: Do not run signal or communications wiring and power
wiring through the same wire conduit. To avoid interference, wires
with different signal characteristics should be routed separately.
You can use the type of signal transmitted through a wire to
determine which wires should be kept separate. The rule of thumb
is that wiring sharing similar electrical characteristics can be
bundled together.
You should separate input wiring from output wiring.
We advise that you label the wiring to all devices in the system.
This product is intended for installation in Restricted Access
Location.
WARNING
Hot Surface. Do not touch.
ATTENTION
The SFP module only supports Laser Class 1 optical
transceivers.
Grounding the EDR-8010 Series
Grounding and wire routing help limit the effects of noise due to
electromagnetic interference (EMI). Run the ground connection from
the ground screw (M4 type) to the grounding surface prior to
connecting devices.
ATTENTION
This product is intended to be mounted to a well-grounded
mounting surface such as a metal panel. Use the green-andyellow cable type AWG (American Wire Gauge) min.18 (0.75
mm2) for grounding.
-8https://manual-hub.com/
Wiring the Redundant Power Inputs
The EDR-8010 Series has two sets of power inputs—power input 1 and
power input 2. The top and side views of the terminal block connector
are shown below.
The input terminal block (TB1) should be installed using 16-24 AWG
wires. The wiring for the input terminal block must be installed by a
skilled person. Wire Type: Cu
The power cord adapter should be connected to a socket outlet with an
earthing connection. The power cord and adapter must comply with
Class I construction.
Instructions
This product is intended to be supplied by a UL Listed Power Adapter or
DC power source marked ‘L.P.S’ or ‘Limited Power Source’, rated 12 to
48 VDC, 0.53 A (min.), and Tma 75°C (min.). If you require further
assistance, please contact your Moxa representative.
Top View
Right View
STEP 1:
Use a small flat-blade screwdriver
to press a wire locker.
STEP 2:
Insert a positive/negative DC wire
into
the
V+/Vterminals
respectively.
STEP 3:
Release the wire locker and check
whether the wire is fixed.
Communication Connections
Each EDR-8010 Series has three types of communication ports:
•
•
•
1 Type-C console port (RS-232 interface, baud rate: 115200, 8-N1)
8 10/100BaseT(X) Ethernet ports
2 1G SFP ports
TYPE-C Console Port Connection
The EDR-8010 Series provides one Type-C console port located on the
top panel. Connect the industrial secure router to a PC COM port using
the Type-C-to-DB9 connection cable, and then launch a console
terminal software, e.g. Moxa PComm Terminal Emulator, to access the
EDR-8010 Series’ console configuration utility.
TYPE-C-to-DB9 Cable Wiring
-9https://manual-hub.com/
P1
P2
2
A5
B5
A6
B6
A7
B7
3
5
BROWN
GREEN
RED
BLUE
ORANGE
PURPLE
PIN Definition
Description
TXD
RXD
GND
P1
2
3
5
P2
A5, B5
A6, B6
A7, B7
10/100BaseT(X) Ethernet Port Connection
The 10/100BaseT(X) ports located on the EDR-8010 Series front panel
are used to connect to Ethernet-enabled devices. Most users will choose
to configure these ports for Auto MDI/MDI-X mode, in which case the
port’s pinouts are adjusted automatically depending on the type of
Ethernet cable used (straight-through or cross-over), and the type of
device (NIC-type or HUB/Switch-type) connected to the port. No matter
which case you are connecting, we share pinouts for both MDI (NICtype) ports and MDI-X (HUB/Switch-type) ports.
10/100Base T(x) RJ45 Pinouts
MDI Port Pinouts
Pin
Signal
1
Tx+
2
Tx3
Rx+
6
Rx-
MDI-X Port Pinouts
Pin
Signal
1
Rx+
2
Rx3
Tx+
6
Tx-
8-pin RJ45
The Reset Button
Using a pointed object such as a straightened paperclip or toothpick,
depress the Reset button for five seconds to load the factory default
settings. When pressing down, the STATE LED will start to blink about
once per second. Continue to depress until the STATE LED begins
blinking more quickly, indicating that the device is resetting and you
can release.
NOTE
DO NOT power off the device when loading default settings.
LED Indicators
The front panel of the EDR-8010 Series has several LED indicators. The
function of each LED is described in the following table:
- 10 https://manual-hub.com/
LED
Color
State
On
PWR1
Amber
Off
On
PWR2
Amber
Off
On
Green
STATE
Blinking
Red
On
On
MSTR/
H.TC
Green
Blinking
Off
On
CPLR/
T.TC
Green
Blinking
Off
On
VRRP/HA
Green
Off
Green
VPN
USB
1G
10/100
Mbps
Amber
Green
Red
Green
Green
On
On
Off
On
Blinking
On
On
Off
On
Off
Description
Power is being supplied to power input
P1 on the main module.
Power is NOT being supplied to power
input P1 on the main module.
Power is being supplied to power input
P2 on the main module.
Power is NOT being supplied to power
input P2 on the main module.
The system passed the self-diagnosis
test on boot-up and is ready to run.
Device reset is in progress, blinking
once per second.
The system failed the self-diagnosis test
on boot-up.
The EDR-8010 is set as the Master of
the Turbo Ring, or as the Head of the
Turbo Chain.
The Turbo Ring or the Turbo Chain is
down.
The EDR-8010 is not set as the Master
of this Turbo Ring or is set as a Member
of the Turbo Chain.
The EDR-8010 Series’ coupling function
is enabled to form a backup path, or the
device is set as the Tail of the Turbo
Chain.
The Turbo Ring or the Turbo Chain is
down.
The EDR-8010 Series’ coupling function
is disabled, or the device is set as a
Member of the Turbo Chain.
The EDR-8010 is set as the Master of
the VRRP or HA.
The EDR-8010 is not set as the Master
of the VRRP or HA.
All VPN tunnels are working normally.
Only parts of the VPN tunnels are
working normally.
No active VPN connections.
USB drive successfully connected.
USB data is being transmitted.
USB dongle malfunction.
1G SFP link is up.
No link or the SFP link is down.
10 or 100 Mbps copper link is up.
No link or the copper link is down.
Specifications
Input Current
0.53 A @ 12 V
0.26 A @ 24 V
0.14 A @ 48 V
- 11 https://manual-hub.com/
Input Voltage
12/24/48 VDC, dual power input
DNV-certified for 24 VDC
Power Consumption
6.36 W (max.)
Operating Temperature
Standard models: -10 to 60°C (14 to 140°F)
Wide-temp. models: -40 to 75°C (-40 to
167°F)
DNV-certified for -25 to 70°C (-13 to 158°F)
Storage Temperature
-40 to 85°C (-40 to 185°F)
Compass Safety Distance 400 mm
WARNING
사 용 자 안 내 문
이 기기는 업무용 환경에서 사용할 목적으로 적합성 평가를 받은
기기로서
가정용 환경에서 사용하는 경우 전파간섭의 우려가 있습니다.
- 12 https://manual-hub.com/
">