BURG secuENTRY Set ENTRY 7601 PIN Pincode-Set Instruction manual
Burg secuENTRY Set ENTRY 7601 PIN Pincode-Set empowers you with the convenience and security of keyless entry to your home or office. This advanced system combines the ENTRY 7600 CYL cylinder and ENTRY 7711 Keypad PIN to offer a seamless and protected access solution.
Advertisement
Advertisement
Contents index English Initial setup secuENTRY easy ENTRY 7601 PIN 2 Further languages at: www.burg.biz Foreword Dear Customer, Thank you very much for deciding on the secuENTRY Set ENTRY 7601 PIN, consisting of the ENTRY 7600 CYL cylinder and the ENTRY 7711 Keypad PIN. The system was developed in Germany according to the most modern technical capabilities and fulfils the latest high safety requirements. Setup with app BURGsmart The ENTRY 7600 CYL electronic cylinder can be easily installed in any door with a mortise lock, up to a door thickness of 118 mm (59/59 mm, measured in the centre of the forend screw). No drilling or laying of cables is required and it is ideally suited for both new installations and retrofitting. The ENTRY 7600 CYL can be fitted to house and interior doors. Using the ENTRY 7711 Keypad PIN, you can unlock and lock the door with a 6-digit user code. The ENTRY 7711 Keypad PIN can be installed up to approx. four metres from the locking unit, depending on preference and conditions. The ENTRY 7600 CYL is setup and operated using the free smartphone app BURGsmart*. The transmission is wireless, the cylinder uses the modern Bluetooth 5.2 standard. * Video instructions Simple instructions on the setup and operation of your secuENTRY components. Follow the QR code or go to... BURG-WÄCHTER KG Altenhofer Weg 15 58300 Wetter Germany Alternatively, the cylinder can also be operated by keypad (e.g. ENTRY 7712 Keypad FP), the radio key ENTRY sE-Key 7713, as well as other add-on products (all items available separately. For a complete list of all compatible products, please refer to page 13 of these instructions). The BURGsmart app is however always required for the setup. https://t1p.de/burgsmart-app www.burg.biz ! Important: Please read the entire operating instructions before you start the installation. We hope you enjoy your new locking system! Set contents Technical data - ENTRY 7600 CYL Cylinder II I I ENTRY easy 7600 CYL Cylinder II ENTRY 7711 Keypad PIN III Adapter 1 incl. 2x M2x10 screws V IV Adapter 2 incl. 1x 2.9x13 screw IV III V Emergency lock cover (2x) VI Emergency key VII Forend screw XI VI VIII Adhesive pads (4x) XIV VII Cylinder unit power supply 2x Mignon LR6 AA Alkaline Permitted ambient conditions -15 °C/+50 °C / up to 95 % relative humidity (non-condensing) Radio standard Bluetooth 5.2 LE Transmission power ≤ 10 dBm Frequency range 2.4 - 2.483 GHz Range Approx. 4 m Number of access media Up to 2,000 user codes (incl. one administrator code)*, sE keys** or BURGsmart connections, of which max. 45 fingerprints*** when using a fingerprint keypad or 300 when using the PC software****. Blocking times After 3x incorrect entries of an opening media 1 minute, thereafter 3 minutes each time IX Dowels (3x) XII X Screws (3x) VIII IX XI Hexagon spanner SW2 XIII XII Screwdriver TX8 XIII QR-Code sticker X XIV Quick Start Guide plus warranty and disposal instructions Fig. 1 ! Note: The integrated manipulation protection in the cylinder ensures that the cylinder is blocked for one minute after three incorrect entries of an opening media. From the fourth incorrect entry, the cylinder is blocked for three minutes each time. QR code/Administrator code The QR codes (I) are required later when setting up the set using the BURG-WÄCHTER BURGsmart app (Fig. 1). The sets are delivered from the factory with a random administrator code (II) (Fig. 1), consequently a code change is not mandatory. ! Attention: Neither the QR codes nor the factory-gen- erated administrator code are stored by BURG-WÄCHTER. Recovery is not possible if the codes are lost. It is important to keep the QR code stickers enclosed with the set in a safe place. We further recommend that you photograph the stickers and also archive them digitally. 2 I English Technical data - ENTRY 7711 Keypad PIN I Keypad power supply Permitted ambient conditions I QR QR Radio standard Transmission power Frequency range Range Weather protection class (IP class) II 2x Mignon LR6 AA Alkaline -15 °C/+50 °C / up to 95 % relative humidity (non-condensing) Bluetooth 5.2 ≤ 10 dBm 2.4 - 2.483 GHz Approx. 4 m IP53 The user code can only be used as an opening media in conjunction with the ENTRY 7711 keypad PIN, ENTRY 7712 keypad FP or ENTRY 7722 keypad FP (available as an option. ENTRY 7711 PIN included in the set). Radio key ENTRY sE-Key 7713 available as an option. *** The fingerprint can only be used as an opening media in conjunction with the fingerprint keypad ENTRY 7712 Keypad FP or ENTRY 7722 Keypad FP (available as an option). **** Additional input of fingerprints is possible using Windows software ENTRY 7783 Pro and the programming device ENTRY 7073 Enrolment (both available as an option). * ** Cylinder QR code sticker Keypad QR code sticker Fig. 1 secuENTRY easy | ENTRY 7601 PIN Set the keypad to programming mode ENTRY 7711 Keypad PIN The ENTRY 7711 Keypad PIN can be used to operate electronic secuENTRY cylinders from BURG-WÄCHTER. Communication between the keypad and the profile cylinder is 128-bit AES encrypted. Operation on the illuminated keypad is carried out via push-buttons. Consequently, the keypad can be easily operated even in poor lighting conditions. The ENTRY 7711 Keypad PIN enables the door to be opened and closed with the aid of a 6-digit PIN code (= 1 million number combinations). The keypad is splash-proof on all sides according to IP53 certification. Please refer to this chapter if the keypad has to be set to programming mode in the course of the setup. Position the smartphone and keypad within Bluetooth range of each other and carry out the following steps. Fig. 2 1 When you reach the view shown in the illustration (Fig. 1), briefly lay the smartphone aside and set the keypad to programming mode using the following steps. Fig. 3 In order for the data transfer ! Attention: between smartphone and keypad to occur, the smartphone must be in direct proximity to the keypad for the following step (Bluetooth range) ON button Entry prompt 2 Activate the keypad with the ON button (Fig. 2). Status LED CLOSE button Status LED Fig. 4 Fig. 5 Fig. 6 The security code can be found ! Note: on the enclosed QR code sticker (Fig. 3). The security code (SCD) serves as ! Note: manipulation and theft protection Cylinder status Fig. 1 Activates the keypad. An entry "Opened" (ON button) or "Closed" (CLOSE button) is generated in the secuENTRY cylinder history. This allows for the "Open" and "Close" operations to be differentiated CLOSE button in the history. The two LEDs next to the X symbol will illuminate if an invalid number Error message combination is entered or if general errors occur. The system monitors the keypad and cylinder battery voltage. The user is alerted as soon as the battery voltage reaches a critical Battery status range. Batteries must be changed as soon as possible after the battery status symbol illuminates. When the number combination entered is correct, the cylinder status Cylinder status symbol will illuminate and the door can be unlocked or locked. The LEDs illuminate one after the other in a clockwise direction when Status LED the keypad is in programming mode (see chapter below). 3 I English Fig. 1 3 Enter the security code (SCD) provided using the keypad. Battery status ON button 5 seconds 4 Press and hold the CLOSE button for five seconds (Fig. 4) until the signal LEDs on the keypad illuminate one after the other in a clockwise direction (Fig. 5). 5 The keypad is now in programming mode. Perform the further steps using the smartphone again (Fig. 6). secuENTRY easy | ENTRY 7601 PIN ENTRY easy 7601 PIN activation I - User 1 First of all, download the BURGsmart app in order to be able to set up your new locking system. This can be found in the iOS App Store and Google Play Store (Fig. 1). BURGsmart Fig. 1 The Android version of the ! Note: BURGsmart app has been used for these 4 I User data 5 3 Enter your name and a mail address (Fig. 3). 3 An overview of the user data appears. If you have created a new user, first enter the first name and surname of the user (I) (Fig. 3). Access data This section allows you to enter ! Note: the desired opening media (e.g. user 6 Fig. 2 Fig. 3 5 Read through and agree to the terms of use and privacy policy (Fig. 3). code or fingerprint) for the user (II) (Fig. 3). The lock opening by smartphone is automatically stored in the administrator's user profile. Access data | User code 6 Tap on "Register" (Fig. 3). ! II To do so, tap the "+" in the top righthand corner (II) (Fig. 2). 2 You will be shown licence provisions for the use of the app when you open it for the first time. Carefully read them and then confirm by clicking "OK" in the bottom right-hand corner (Fig. 2). 4 Select them the item: "BURG-WÄCHTER Cloud" this is not required for the setup and can therefore be ignored for the time being ( Fig. 3). An explanatory note on this subject can be found in the master operating instructions on our website (see link on the title page). 2 A list of the users that have already been created is displayed. A user profile with a lock opening via smartphone has already been automatically created for the administrator. Tap on this (I) (Fig. 2). Alternatively, a new additional ! Note: user profile can be created at this point. 3 instructions. The iOS version can be slightly different visually, but the work steps are identical. 1 Tap on the menu item "I - User" (Fig. 1). Fig. 1 Fig. 2 I II III 4 Enter a required 6 digit user code under "Enter 6-digit code" (III) (Fig. 3). Note: An e-mail window opens with a mail template which you can use to send the registration data to the specified e-mail address. This is necessary, for example, when using the secuENTRY Windows software. It is not required for the setup described here. The data can also be called up again in the app at a later time if required. Fig. 3 7 The BURGsmart app main screen appears. Open the "My System" menu at the bottom left (Fig. 4). Fig. 4 4 I English secuENTRY easy | ENTRY 7601 PIN If you wish to enter opening ! Note: media for other users, go back one Access data | Enter RFID tag 5 An RFID transponder ENTRY 7710 RFID (optionally available) can be entered at this point. Instructions on how to set this up can be found in the RFID transponder instructions (I) (Fig. 4). ! menu and select the respective user (Fig. 7). Repeat the steps in this chapter for this user. 8 You can now leave the menu (I - User). Return to the "My System" menu (Fig. 8). Attention: This cylinder in this set requires the add-on article ENTRY 7174 RFID Extender for the use of RFID transponders. For a complete list of all compatible products, please refer to page 14 of these instructions. I II III Access data | Enter sE-Key 6 A radio key ENTRY sE-Key 7713 (optionally available) can be stored at this point (II) (Fig. 4). Instructions on how this is setup can be found in the radio key instructions. Fig. 4 Fig. 7 Fig. 8 Access data | Smartphone as key The lock opening by smartphone ! Note: is automatically stored in the administrator's user profile (III) (Fig. 4). A different smartphone as the electronic key can be stored in this field for additional users. An instructions on this subject can be found in the master operating instructions on our website (see link on the title page). Manage fingerprint 7 If you have the optional fingerprint keypad (e.g. ENTRY 7712 FP), you can store then register a finger as the opening media in this section. Instructions on how to set this up can be found in the instructions for the respective item (Fig. 5). Fig. 5 Fig. 6 The ENTRY 7711 PIN pincode ! Note: keypad is included in this set. 5 I English secuENTRY easy | ENTRY 7601 PIN II - secuENTRY units 5 The capture window of the camera opens. Scan the QR code. 1 Tap on the second menu item "II - secuENTRY units" (Fig. 1). 6 A message appears containing data regarding your cylinder; confirm this with "OK" at the bottom right (Fig. 4). 2 The app displays a list of the cylinders that have already been registered. This is empty during the initial setup. Setup a new cylinder by tapping on the "+" in the top right-hand corner (Fig. 2). 7 In the following window, you will be prompted to assign a name for the cylinder. Where several cylinders and secuENTRY components are used, it is recommended to name the cylinder in such a way that you can directly identify what it is and where the cylinder is located or attached. In the example in these instructions, the cylinder is titled "Front door cylinder". Confirm the name with "OK" (Fig. 5). Fig. 1 3 A prompt will appear asking you to scan the cylinder QR code provided using your smartphone camera (Fig. 3). The QR code is on the sticker enclosed in the packaging (Fig 4.). Fig. 2 Fig. 5 Fig. 6 Fig. 7 Fig. 8 Note: The randomly generated ad! ministrator code can be found on the enclosed QR code sticker under “ADM”. (Fig. 9). The administrator code can be changed at any time at a later date. Refer to the master operating instructions on our website for an explanation on this subject (see link on the title page). QR The set comes with two ! Attention: QR code stickers, one for the cylinder and one for the keypad. You can identify the QR code required here for the cylinder by the administrator code at the bottom of the sticker, marked "ADM" (Fig. 3). 8 A message appears informing you that you can change your administrator code. As you received a randomly generated administrator code at the time of delivery, this step is optional. You can bypass this with “Skip” (Fig. 6). 9 In order for the keypad to receive the information on which cylinder it is to control, this cylinder must be available and assigned within the app. Fig. 3 Cylinder QR code sticker 4 Tap on "Next" (Fig. 4). You may be asked to confirm the app's access to the camera. Fig. 4 The next menu (Fig. 8) offers you the following three options: • „Link to an existing keypad“: You have already setup a keypad in the app and want to link it again. • „Link to a new keypad“: You have another keypad and want to link it to the app. • „Skip“: Carry out this step at a later date. QR The keypad of the ENTRY 7601 ! Note: PIN set is already set up at the factory and connected to the locking cylinder. Consequently, you can skip this menu item and continue directly to the next chapter. 10 Tap on „Skip“ (Fig. 8). 6 I English Fig. 9 Cylinder QR code sticker secuENTRY easy | ENTRY 7601 PIN 6 Here you will be asked to verify yourself with your administrator code. Enter the code and confirm with “OK” (Fig. 5). III - Locking plan 1 Use this menu to define the locking plan, namely which user is allowed to open which lock. The data is then transferred to the cylinder. The factory administrator code ! Note: can be found on the QR code sticker of the cylinder under “ADM” (Fig. 9). 2 Open the “My System” menu (I) (Fig. 1). 3 Tap on the fourth menu item “III - Locking plan” (Fig. 1). I I II Fig. 1 Fig. 2 info: This table is of interest when ! For you have several cylinders and users. This allows you to clearly determine in one step who is allowed to access which cylinder. Fig. 3 provides an example of what a completed table with corresponding cylinders and users might look like. II 9 You will be asked to set the keypad to programming mode (Fig. 8). Instructions on how to do this can be found in the chapter “Setting the keypad into programming mode” on page 3. As soon as the keypad is in programming mode, indicated by the LEDs on the keypad flashing continuously, tap the “LEDs flashing continuously, continue” key in the app (Fig. 8). Fig. 5 Fig. 6 Fig. 7 Fig. 8 10 Nach einem kurzen Moment erhalten Sie eine Rückmeldung, dass die Daten übertragen wurden. Bestätigen Sie mit „OK“. The following step requires ! Attention: the smartphone, keypad and cylinder The setup is now completed. Repeat the steps in the respective chapters if you wish to integrate further components into your system at a later date, change access data or create additional users. to be in direct proximity to each other (Bluetooth range). 5 If any changes have been made to the locking plan, the display of the respective cylinder appears red and the „Program“ button is displayed. This indicates that the settings have not yet been transferred to the cylinder. To do this, tap the red „Program“ button for the respective cylinder (Fig. 4). I 8 Select the required keypad (Fig. 7). II 4 A table is displayed consisting of the existing cylinders (horizontal) and the configured users (vertical) (Fig. 2). Select the checkbox where you wish to authorise the respective user to use the corresponding lock (I) (Fig. 2) and then click on the button „Save changes“ (II) (Fig. 2). 7 The data will be transferred. A confirmation will appear after a brief moment and at the same time a request to now assign the keypad. Tap on the confirmation message (Fig. 6). Fig. 3 Fig. 4 Please note: All changes and additions are carried out within the app and must then be transferred to the respective secuENTRY component. This last chapter, “Locking plan” (page 8) must be completed in each case in order to be able to use them in your components. QR Fig. 9 QR-Code Aufkleber Zylinder 7 I English secuENTRY easy | ENTRY 7601 PIN Opening the secuENTRY lock via the keypad (user code) Using the cylinder and keypad 1 Activate the keypad by pressing either the ON key or the CLOSE key (I) (Fig. 4). To use the cylinder (Fig. 1) and keypad (Fig. 2), remove the battery protection strips. Fig. 1 Fig. 2 Opening the secuENTRY lock The ENTRY 7601 PIN set enables you to open the lock via the BURGsmart app or the keypad using a user code, provided you have set up the corresponding opening media in accordance with these instructions. Opening the secuENTRY lock with the BURGsmart app Further details on the history ! Note: function can be found in the master operating instructions on our website (see link on the title page). 1 Open the BURGsmart app and press the "ACCESS" button in the middle (Fig. 1). DO NOT TAKE OUT SCREWS The BURGsmart app is pro! Note: grammed so that when more than one cylinder is used, it automatically adjusts to the cylinder that is within the shortest distance of the smartphone. Each cylinder can be opened by pressing the "ACCESS" button. ! Note: Further details on the subjects of administrator and user codes can be found in the chapters "QR code/administrator code" on page 2 and "I - User" on page 4, as well asin the in the master operating instructions on our website (see link on the title page). 3 When the number combination entered is correct, the cylinder status symbol ( ) will illuminate and the door can be unlocked (Fig. 5) or locked (Fig. 6). Low strength. ! I Fig. 4 Fig. 5 max. ca. 0,4 Nm Note: Depending on the door stop, the direction of rotation may be reversed. DO NOT TAKE OUT SCREWS 2 The cylinder is now released and the lock can be opened (Fig. 2) or locked (Fig. 3). II 2 Enter your 6-digit administrator code or programmed user code (II) (Fig. 4). Proceed as follows to open the ENTRY 7600 CYL cylinder and consequently also the door: ! I An entry "Opened" (ON button) or "Closed" (CLOSE button) is generated in the cylinder history. This allows for the "Open" and "Close" operations to be differentiated in the history. Fig. 6 Low strength. max. ca. 0,4 Nm Fig. 1 Note: Depending on the door stop, the direction of rotation may be reversed. DO NOT TAKE OUT SCREWS Low strength. max. ca. 0,4 Nm Fig. 2 8 I English Fig. 3 secuENTRY easy | ENTRY 7601 PIN Opening the secuENTRY lock with the emergency lock Assembly of the ENTRY easy 7600 CYL The installation of the ENTRY easy 7600 CYL is explained below. Prior to installation, please read the installation instructions carefully. Should the batteries in the locking cylinder be completely discharged, the lock can still be opened mechanically. The emergency lock is located on the outer side, below the knob attachment. ! 1 Remove the existing door lock cylinder by loosening the forend screw in the door and pulling out the cylinder with the key inserted (Fig. 1). Note: When the assembly steps in these instructions have been completed, the emergency lock is behind a cover and is not directly visible. 1 To open the lock, open the emergency key at the joint and then insert it through the indicated slot on the emergency lock cover (Fig. 11). 2 Turn the key 90 degrees clockwise. If required, move the outside knob slightly to the right and left in order to release the mechanism. The lock is open after at least two full turns of the cylinder knob. 3 After opening the door, turn the emergency key back to its original position (90 degrees counterclockwise) and remove it. 4 To return the locking cylinder to its regular locking position, turn the outside knob two complete turns in both directions. This engages the mechanism and the emergency lock is fully closed. When the emergency lock is ! Note: used, the keyhole indication on the emergency lock cover is torn. A second cover is included in the set so that it can be replaced for aesthetic reasons. 9 I English Fig. 11 Please note, the emergency ! Attention: lock is designed for emergency openings only. Please do not use it as a permanent alternative to the standard locking options. 2 The loosening and fixing of the outer and inner knob is achieved by means of an integrated grub screw in the rotary knob. Loosen the two grub screws in the two knobs with the enclosed hexagonal spanner (Fig. 2). ! Attention: Use the long side of the hexagonal spanner for this. Turn the screw four times anticlockwise. Do not remove the screws from the knob. 3 Pull off the knob on the outside completely and pull the knob on the inside as far back as possible (Fig. 3). ! Tip: The knob is in the inner side of the battery compartment. Pay attention to the battery compartment cover with the screw hole (see diagram). 2. Fig. 1 1. 4x 2 mm DO NOT TAKE OUT SCREWS DO NOT TAKE OUT SCREWS Fig. 2 DO NOT TAKE OUT SCREWS The knob on the inside ! Attention: cannot be pulled off. Do not try to loosen it by force, as pulling the knob from the shaft will destroy the electronics. The grub screw in the knob serves as a pull-off protection. Fig. 3 secuENTRY easy | ENTRY 7601 PIN 4 Adapters may be required depending on the door thickness. Door outer side Door inner side If the distance between the forend screw and the outer side of the door (Fig. 4) is... Forend screw 6 Screw the cylinder into the door and push the inside and outside knobs up to the door (Fig. 9). • < 43 mm = no adapter required (Fig. 5) • 44 - 53 mm = Adapter 1 required (Fig. 6) Push adapter 1 onto the lock shaft and screw it tight with the two M2x10 screws provided. Distance in mm Fig. 4 Without adapter Fig. 9 • 54 - 59 mm = Adapter 1 and 2 required (Fig. 7) After adapter 1 has been attached (see above), then also push adapter 2 onto the lock shaft. Screw it tight with the 2.9x13 screw provided. Fig. 5 Adapter 1 DO NOT TAKE OUT SCREWS ! emergency lock cover is torn. A second cover is included in the set so that it can be replaced for aesthetic reasons. min. 1 mm Ensure that the ! ATTENTION: knob is at least one millimetre DO NOT TAKE OUT SCREWSDO NOT TAKE OUT SCREWS Attention: Use the long side of the hexagonal spanner for this. Turn the screw clockwise DO NOT TAKE with OUT(max. SCREWS minimal force torque approx. 0.4 Nm). Low strength. max. ca. 0,4 Nm DO NOT TAKE OUT SCREWS Adapter 2 Note: Before assembling the cover, the protective films of the adhesive pads on the back of the cover must be removed so that the three adhesive pads securely fasten the cover to the cut-out/door. When the emergency lock is ! Note: used, the keyhole indication on the min. 1 mm away from the door. Fig. 6 5 From inside the door, push the cylinder into the mortise lock. Push the emergency lock cover onto the outer side of the locking shaft (Fig. 8). 7 Screw the grub screws back into the two knobs (Fig. 10). 8 If you have not already done so, remove the battery protection strip from the battery compartment on the inside knob (Fig. 11). 2 mm Low strength. max. ca. 0,4 Nm Low strength. max. ca. 0,4 Nm Low strength. Fig. 10 max. ca. 0,4 Nm Low strength. max. ca. 0,4 Nm Fig. 7 OUTDOOR ! Fig. 11 INDOOR 1 3 2 < 43 mm = 1 44 - 53 mm = 2 54 - 59 mm = 3 10 I English Fig. 8 secuENTRY easy | ENTRY 7601 PIN ENTRY 7711 Keypad PIN installation - screw mounting The installation of the ENTRY 7711 Keypad PIN is explained below. There are two options to choose from for installation. The ENTRY 7711 Keypad PIN wall bracket can either be screwed or adhered directly to the wall. 2 Insert the dowels supplied into the holes and screw in the screws provided (Fig. 2). Prior to installation, please read the installation instructions carefully. ENTRY 7711 Keypad PIN installation - function test prior to installation 40 mm 1 Drill three holes according to the dimensions shown in the illustration. Use a 6 mm diameter drill bit (Fig. 1). 61 mm ENTRY 7711 Keypad PIN installation ! ATTENTION: The distance between the cylinder and the keypad can be up to a maximum of four metres. This distance may vary, however, depending on external conditions. In order to ensure that the keypad functions correctly in the desired position, we recommend testing it first before installation. Ø 6 mm Fig. 2 3 Remove the screw from the bottom of the keypad using the Tx8 screwdriver supplied with the keypad and pull the battery compartment downwards (Fig. 3). max. 4 m 1 Place the keypad in the desired installation location (Fig. 1). Fig. 1 2 Enter your administrator or user code and check that the cylinder is activated (Fig. 2). Fig. 3 The administrator code, if you ha! Note: ven't already changed it, can be found QR on the QR code sticker enclosed with the secuENTRY cylinder (Fig. 3). For information on how to create a user code, see the chapter "I - User" on page 4. 3 If the cylinder activates, the signal strength is sufficient and the keypad can be installed in the desired location. If not, try again with a shorter distance between cylinder and keypad. Fig. 1 Fig. 2 4 Place the keypad on the screw heads as shown in the illustration (Fig. 4). Fig. 3: QR code sticker for secuENTRY cylinder. Factory-assigned administrator code Fig. 4 5 Insert the battery compartment back into the housing and screw it tight (Fig. 5). Fig. 5 11 I English secuENTRY easy | ENTRY 7601 PIN ENTRY 7711 Keypad PIN installation - adhesive mounting Battery status display and replacing the batteries 1 Clean the surface to which the keypad is to be attached (Fig. 6). ENTRY 7600 CYL cylinder The battery status is shown on the display each time a secuENTRY cylinder is activated via the BURGsmart app (Fig. 1). When the batteries in the cylinder are running low, replace them as soon as possible. Fig. 6 2 Attach the enclosed adhesive pads to the positions shown in the illustration and peel off the backing strips (Fig. 7). The batteries are located in the ! Note: cylinder knob on the inside of the door. If the battery status is ignored and the batteries become completely discharged, you can only open the cylinder from the outside using the emergency lock. For further information, please refer to chapter "Opening the secuENTRY lock with the emergency lock" on page 9. Instructions on replacing the batteries are given below: Fig. 1 Fig. 7 TX8 1 Using the TX8 screwdriver provided, loosen the screw on the inner side of the door at the front end of the knob and open the cover. The screw can only be unscrewed up to the opening of the cover and will not fall out. (Fig. 2). 3 Mount the keypad on the wall in the desired position (Fig. 8). Fig. 2 2 Remove the old batteries and dispose of them appropriately. Fig. 8 Instructions for proper disposal ! Tip: can be found on page 14 of these instructions. 3 Insert two new batteries. Make sure that the polarity is correct according to the drawing (Fig. 3). 4 Press the keypad against the wall for approx. one minute (Fig. 9). ! Attention: Only press the outer edges of the hous- ing. To avoid damage to the electronics, do not press within the keypad area. Fig. 3 1 Min. 4 Replace the front cover and screw it on tightly (Fig. 4). ! Fig. 9 TX8 Fig. 4 12 I English secuENTRY easy | ENTRY 7601 PIN Compatibility with other secuENTRY products ENTRY 7711 Keypad PIN Whether for one front door, several doors or a complete locking system: Simply configure your individual unit with the secuENTRY modular system. The system monitors the keypad and cylinder battery voltage. The user is alerted as soon as the battery voltage reaches a critical range. Batteries must be changed as soon as possible after the battery status symbol illuminates on the keypad (Fig. 5). Your ENTRY 7600 CYL cylinder can be extended with the following components: secuENTRY Keypad ENTRY 7711 PIN / 7712 FP It is recommended that the ! Tip: batteries in the cylinder and keypad are always replaced at the same time. Nonetheless, the battery status of the cylinder can be checked separately at any time. The current battery status is displayed on the BURGsmart app main screen (Fig. 6). Instructions on replacing the batteries are given below: Fig. 1 Fig. 5 Fig. 6 A keypad ENTRY 7711 Keypad PIN is already included in this ENTRY 7601 PIN set. Further information can be found on our website: www.burg.biz ENTRY 7712 FP: 4003482507124 www.burg.biz ENTRY 7722 FP: 4003482507223 Further information can be found on our website: www.burg.biz Fig. 2 secuENTRY Radio key ENTRY sE-Key 7713 Tip: Instructions for proper disposal can be found on page 15 of these instructions. Fig. 7 Fig. 8 Fig. 3 3 Insert two new batteries. Make sure that the polarity is correct according to the drawing (Fig. 9). The cylinder is opened simply by pressing a button using the ENTRY sE-Key 7713 radio key. The transmission is encrypted at a high security level (AES encryption). secuENTRY Transponder ENTRY 7710 RFID Insert the battery compartment back into the housing and screw it tight (Fig. 10). Fig. 4 Fig. 9 13 I English Further information can be found on our website: The ENTRY 7722 FP display keypad enables opening with a 6-digit user code or fingerprint. 2 Remove the old batteries and dispose of them appropriately. ! Using the ENTRY 7711 Keypad PIN, you can unlock and lock the door with a 6-digit user code. In addition, with the ENTRY 7712 Keypad FP also with fingerprint. secuENTRY Keypad ENTRY 7722 FP 1 Remove the screw from the bottom of the keypad using the Tx8 screwdriver supplied (Fig. 7) with the keypad and pull the battery compartment downwards (Fig. 8). ENTRY 7711 PIN: 4003482507117 The modern passive transponder provides door opening with contactless data transmission. Attention: The ENTRY 7174 RFID Extender add-on is additionally required for use with the ENTRY 7600 CYL cylinder. Article number: 4003482507131 Further information can be found on our website: www.burg.biz Article number: 4003482568200 Further information can be found on our website: www.burg.biz Fig. 10 secuENTRY easy | ENTRY 7601 PIN secuENTRY Add-on ENTRY 7174 RFID-Extender RFID transponder reader. Can be used for cylinders or, in conjunction with an ENTRY 7171 Relay, for external electronic devices. Warranty Article number: 4003482501740 Further information can be found on our website: www.burg.biz When returning goods due to your right of withdrawal, all parts of the appliance must also be in their factory settings. Failure to comply with this will invalidate the warranty. Fig. 5 secuENTRY Add-on ENTRY 7171 Relay Fig. 6 Control unit for switching external electronic devices (shutters, barriers, light sources, etc.). secuENTRY Add-on ENTRY 5670 Bridge Fig. 7 Your new found freedom: Using the secuENTRY Bridge via the internet you can open your door even when you are out and about. secuENTRY Add-on ENTRY 7172 REMOTE For automatic remote activation. Control of electronic garage motors, alarm systems, etc. In order to deliver a flawless and high quality product to you and to better assist you in case of service or repair, it is necessary that faulty or defective devices along with the valid administrator code and the QR code(s) be presented to your dealer together with the original documentation. Article number: 4003482506707 Further information can be found on our website: Disposal of the device www.burg.biz Please help to reduce waste. Should you intend to dispose of this device at any time, please remember that many components of this device contain valuable materials that can be recycled. Article number: 4003482562802 Further information can be found on our website: www.burg.biz Article number: 4003482501726 Further information can be found on our website: Article number: 4003482507506 Provides convenient user management of up to 15 users and 8 locks. Further information can be found on our website: secuENTRY Windows-Software ENTRY 7783 Software Pro Article number: 4003482507834 lease note that electrical and electronic devices as well as batteries must not be P disposed of with household waste but rather apart from it or separately. Please obtain information on the collecting points for electrical waste from the responsible authority of your city/municipality. URG-WÄCHTER KG hereby declares that this device complies with the Directives B 2014/53/EU, (RED) and 2011/65/EU (RoHS). www.burg.biz The complete text of the EU Declaration of Conformity is available at the following Internet address https://burg.biz/pages/eu-konformitaetserklaerung. Fig. 8 secuENTRY Windows-Software ENTRY 7750 Software Light Dear customer, www.burg.biz Fig. 9 Fig. 10 Designed specifically for companies and public authorities. Allowing the management of up to 2,000 users and up to 1,000 doors per client (database) or up to 500 doors in hotel mode. Further information can be found on our website: www.burg.biz Printing and typesetting errors as well as technical changes reserved. 14 I English secuENTRY easy | ENTRY 7601 PIN BD Initial setup ENTRY easy 7601 PIN EN HBG/SWI 030723 secuENTRY easy ENTRY 7601 PIN BURG-WÄCHTER KG Altenhofer Weg 15 58300 Wetter Germany www.burg.biz www.burg.biz ">
Download
Advertisement
Key features
Keyless entry: Unlock your door with a 6-digit PIN code
Easy to install and use: No drilling or wiring required
Wireless: The cylinder uses the modern Bluetooth 5.2 standard
Up to 2,000 user codes: Share access with family and friends
Integrated manipulation protection: Blocks the cylinder after three incorrect entries
Splash-proof keypad: IP53 certified for outdoor use
Frequently asked questions
The system is easy to install and use, and it can be used on any door with a mortise lock, up to a door thickness of 118 mm. No drilling or wiring is required.
To unlock your door, simply enter your 6-digit PIN code on the keypad.
You can change the PIN code using the BURGsmart app.
The system can store up to 2,000 user codes.