PREFACE

Thank you for purchasing AMICO diesel generators.

This operation manual will tell you how to operate and service your AMICO generation set correctly.

Please read this manual before using the generating set to ensure the proper operation.

Follow the instructions to keep your generating set in the best working condition and extend the life of it. If you have any commends or problem, please contact with our sales company or the authorized agent.

This manual deals with the general items of the AMICO diesel generating set. However, the manual may vary with the development of the products in the future.

Please give special attentions to warnings and cautions.

!

WARNING

Failure to properly follow these precautions can result in property damage, serious injury or DEATH!

Read all labels and the owner's manual before operating this generator.

Operate only in well ventilated areas. Exhaust gas contains poisonous carbon monoxide, and can be deadly. Always stop engine before refueling. Wait 5 minutes before restarting.

Check for spilled fuel or leaks. Clean and/or repair before use.

Keep any sources of ignition away from fuel tank, at all times.

!

WARNING

Indicates that the severe personal injury even death will result if the instructions are not followed.

!

CAUTION

Indicates that the serious personal injury or equipment damage will result if the instructions are not followed.

AMICO diesel generating set will meet your requirement if you operate it according to the manual instruction. Otherwise serious personal injury and equipment damage will result.

So, AMICO reconfirms that ou must to read and understand this manual before operating the generating set.

ST

OP

WARNING:

!

CAUTION

1. TO PREVENTTHE FIRE

Never add fuel to the fuel tank while the engine is running.

Wipe off the overflowed fuel oil with a clean cloth. Keep explosives and other

flammable products away from the generating set.

To prevent the fire and to I~rovide adequate ventilation, keep the generating set at

least one meter away from buildings and other equipment during operation.

Operate the generating set on a level surface,

Do not put the generating set indoors while the engine is hot.

2. TO PREVENT FROM INHALING THE EXHAUST

Exhaust gas contains poisonous carbon monoxide, which is harmful to the health.

Never use the generating set at the confined places or poor ventilated locations,

If it's necessary to run the generating set indoors, be sure to provide the ad-

equate ventilation.

3. BE CARE NOT TO BE SCALDED

The muffler and the engine body are very hot while the engine is running or just

after running, do not touch these parts to prevent from being scalded.

4. ELECTRIC SHOCKS, SHORT CIRCUITS

To avoid electric shocks or short circuits, do not touch the generating set when

your hands are wet. This generating set is net waterproof, so it should not be

used in a place exposed to rain snow or water sprays. Use of the generating set

tor in a wet place can cause short circuits and electric shocks during operation.

The generating set should be grounded to prevent electrical shocks from faulty

appliances. Connect a length of heavy wires between the generating set s ground

terminal and an external ground source.

Do not hook up tools or other apparatus to generating set rator before it has been

started. If equipment is attached, generator starting may cause sudden move-

ments of the equipment and result in injuries and accidents. Be sure to discon-

nect any apparatus from the generating set or prior to starting.

!

CAUTION

Most appliance motors require more than their rated wattage for start-up.

Do not exceed the specified current limit of any socket.

Do not connect the generating set to a household circuit. This could cause damage to the generating set and to electrical appliances in the house.

CONTENTS

Main Technical Specifications and Data

Cofiguration

Preparation for Starting

Start the Generating Set

Operate the Generating Set

Load

Stop the Generating Set

Periodic Checks and Service

Long-term Storage

Troubleshooting and Remedy

Detail Diagram

Panel Detail Diagram

Wiring Diagram

LIMITED WARRANTY

PRODUCT REGISTRATIONCARD

18

19

20

10

14

14

24

26

27

28

3

7

9

1

2

1. MAIN TECHNICAL SPECIFICATIONS AND DATA

Model

Item

Rated frequency (Hz)

Rated power (kVA)

Rated voltage (AC)(V)

Rated current (AC)(V)

Rated revolution speed(r/min)

Power factor (cos )

Excitation mode

DC output

Operation mode

Coupling method

Engine Model

Gross weght(kg)

Overall dimensions(LxWxH)(mm)

AH4000LN

60

4.0

120/240

33/16.5

3600

1

Controlled silicon self excitation constant voltage

12V/8.3A

12 hour continuous running

Transmission rigid connection

AHD186

165

950x565x760

1

2.CONFIGURATION

2.1 Parts name

AC output

DC output

Engine starter switch

Exhaust

Lifting eye

Fuelfiller cap

Low oil pressureg lamp

Outlet fo cooling air

2

2.2 Control panel

AH6000LN

3. PREPARATION FOR STARTING

3.1 Selection and handling of the fuel oil

Selection of fuel oil

Only use the light diesel, which is most suitable for the engine,

Keep dust and water out of the fuel

When filling the fuel tank from drums, make sure that no dust or water is mixed in

the fuel. Otherwise the serious fuel injection pump and nozzle problems will result

Do not overdill

Overfilling is very dangerous, De not fill the tank beyond the top of the red plug

inside the fuel oil fillter.

!

WARNING

Refuel in a well-ventilated area with the engine stopped.

Do not smoke or allow flames or sparks in the area where the engine is refueled or where the fuel oil stored,

Do not overfill the tank, make sure the filler cap is securely closed after refueling.

Be careful net to spill fuel when refueling. If any fuel is spilled, make sure the area is dry before starting the engine.

3

3.2 Check and refill the engine oil

!

WARNING

Always check the engine oil level with the generating set on a level surface before starting and refill if necessary.

The engine may be damaged if operated with insufficient engine oil, it is also dangerous to refill too much engine oiI as sudden increase in engine speed may be caused by its combustion.

!

WARNING

AMICO series generating set are equipped with Iow oil warning system This system will stops the engine automatically when the oil level falls below the lower level. This prevents accidents such as bearing seizures, etc.

Select the most applicable engine oil

It is very important to select the applicable engine oil for keep up the performance and life of the generating set, If inferior engine oil is used, or it your engine oil is not replaced periodically, the risk of piston seizure, piston ring sticking and accelerated wear of the cylinder liner, bearing and other moving components increases significantly. So the generating set life will be shortened AMICO recommends

CC/CD oil classified by APl. Choose the applicable viscosity oil according to the local ambient temperature.

3.3 Service the air cleaner

1. Screw off the wing nut remove the air

cleaner cover and take out the element.

!

WARNING

Do not wash the element with detergent.

Replace the element when its output decrease or a bad exhaust color is noticed.

Never run the generating set without the element, otherwise the rapid engine wear will result.

Air cleaner inspection port cover

4

2. Reattach the air cleaner cover and screw

on the wing nut.

Elelment

3.4 Check the generating set

1. Turn off the main switch and any other

loads.

Low oil warning lamp

!

WARNING

Be sure to turn offthe main switch before starting.

The generating set should be earthed to prevent electric shocks.

AC output receptacle

!

WARNING

The generating set should be earthed to prevent electdc shocks.

Ground terminal

Ground terminal

5

2. Handling of dual voltage type generat-

ing sets

Be sure to place the changeover switch

in the correct position for the rated volt-

age of the working instrument.

Change-over switch

!

CAUTION

The main switch should always be kept in the "ON" position during operation.

Before starting the engine, be sure to turn the switches of the working instrument (lighting apparatus, motor, etc.) to their "OFF" position. If the switches are not "OFF", the sudden application of load when the engine is started could be very dangerous.

3-5 How to open the cabinet door and covers of AMICO LN series generating set

1. Open the cabinet door for daily inspection.

Tum the lever counter clockwise and raise

the door.

2. Loosen the bolt of the air cleaner check

port cover to check the air cleaner.

3. Screw off the wing nut to open the cover,

then check the nozzle cover.

3.6 Break-in period operation

The first 20hrs are the break-in period of the engine, the operator must obey to following items:

Warm up the engine 5 minutes after the initial starting. Run the engine at Iow speed and zero load before the engine becomes warm

6

Avoid applying any heavy loads during the break-in pedod AMICO recommends to run the engine at 3600 r/min with 50% load in break-in period.

Replace the engine oil on time.

Replace the engine oil while the engine is warm after 20-hours -running. the old engine oil will be drained out completely.

Approx. one month or 20hours Every 3 months or 100 hours

4. START THE GENERATING SET

!

WARNING

Do not hook up tools or other apparatus to the generating set before starting.

7

1. Starting

Open the fuel cock.

Set the engine speed lever at "RUN" position.

Engine speed lever

Engine speed aver

Turn the starting key clockwise to

"START" position.

Remove your hand from the key as soon as the engine starts.

If the starting motor does not start after

10 seconds, wait 15 seconds before starting it again.

Engine starter key

!

CAUTION

Run the starting motor for long time will cost the battery power greatly even burn out the molor.

Always leave the starting key at "ON" position while the engine is running.

8

2. Battery

1.when you install it,frist check batteryís polarity if it

is same with generatorís anode &cathode line,check

volt if it is 12.3V,otherwise must electricize,

2.every month check volt if it is right,free charge

maintenance batteryís charge,volt is 13.5V-14.5v

3.check electric systerm if it have creepage,otherwise

damage battery,

4.if batteryís volt is not enough,electrica energy is low,please remove of battery and

electricize, on time,only have 5-6hours is ok,

5.battery put on the place of low temperature,dryness,aeration,clean,three month or

six month must need electricize,

5. OPERATE THE GENERATING SET

5.1 Operate the generating set

1. Warm up the engine without load three

minutes.

2. Concerning the generating set with Low

Oil Warning System, check that the Oil

Alarm Lamp is net lit.

Fuel injection limiting bolt

9

!

CAUTION

For the generating set with Low Oil Warning System, the Oil Alarm Lamp will activated by Iow oil pressure or engine oil shortage, simultaneously, the engine will stop. The engine will stop immediately if restarted without refilling the engine oil Check the oil level and refill.

Do not loosen or readjust either the engine speed limiting bolt or fuel injection limiting bolt, otherwise, the performance will be affected.

5.2 Checks during the running

1. Whether there is abnormal sound or vibration;

2. Whether the engine misfires or runs rough;

3. Check the color of the exhaust. (Is it black or too white?)

If you notice any of the above-mentioned phenomenon happened, stop the eh-

gine and find out the fault cause or contact with AMICO agent.

!

CAUTION

If the engine has been running, the muffler will be very hot, Be careful not to touch the muffler.

Never refill the fuel tank while the engine is running.

6.LOAD

!

CAUTION

DO not start 2 or more machines simultaneously Start them one by one.

Do not use floodlights together with other machines.

10

6.1 AC application

1. Be sure to run the generating set at rated speed, otherwise capacitor will produce

the forced excitation. If the running is for a long time under such condition.

capacitor will be burned out,

2. After switching on the air switch, observe the voltmeter on the panel of the control

cabinet, the voltmeter should point to 120V + 5%(60Hz) for single-phase gener

ating set; 120V/240V + 5%(60Hz) for single-phase generating set, then the loading

can be carried out.

3. When the double voltage generating set changes over the voltage, the air sw.~,l

should be set at "OFF" position Otherwise the generating set and electric devices

will be burned out and damaged.

4. Connect the equipment to the generating set in order Forthematterofthemotor

load, firsPy the heavy-duty motor should be connected, then the light-duty motors

If the operation is false, the generating set will lag or stop suddenly It is neces-

sary to unload the generating set immediately and turn offthe main switch and do

checks.

!

NOTE

If overloading of the circuit trips the AC circuit protector, reduce the electrical load on the circuit, and wait a few minutes before resuming operation.

6.2 DC application

1. DC terminals are only for charging 12V battery,

2 Set the air switch at "OFF" position while charging. On the 12V output terminals,

a charge switch can be connected so the switch can be used for on-and-off

purpose

3. Loncerning the automatic type battery with the leads, be sure to disconnect the

negative leads of the battery while charging.

11

!

CAUTION

Connect the positive and negative poles of the battery with the positive and negative poles of DC terminals separately. Do not confuse them, otherwise the battery and generating set will burn out

Do not connect the positive pole of the battery with its negative pole, otherwise the battery damage will result,

Do not connect the positive pole of the DC terminal with its negative pole.

otherwise the generating set damage will result,

When a large capacity battery is charged, excessive current flows, the fuse for the direct current will burn out,

Do not run the generating set while it is still connected with the battery,

Do not use DC12V and AC at the same time.

!

CAUTION

Battery exhausts explosive gas. Keep sparks, flames, and cigarettes away form the battery. To prevent from creating a spark near the battery, always connect the charging cables to the battery first and only then to the generating set. When disconnecting, you should disconnect the cables at the generating set first.

Charge the battery at a well-ventilated place,

Before charging, remove the cap from each cell of the battery.

Stop charging if the electrolyte temperature exceed 45 C.

12

6.3 Electrical appliance particularly motor-driven equipment will produce very high current while starting, the below table provides the reference for connecting these apparatus to the generator set.

TYPE

WATTAGE

STARTING RATED

TYPICAL

APPLIANCE

EXAMPLE

APPLIANCE

STARTING RATED

Incandescent lamp

Heating appliance

Xl Xl

Incandescent lamp

TV

Incandescent lamp

100W

I00VA

(W)

I00VA

(W)

Fluorescent lamp

X2 Xl .5

Fluorescent lamp

40W

Fluorescent lamp

80VA

(W)

60VA

(W)

Motordriven equipment

X3~5 X2 Refrigerator

Electric fan

Refrigerator

150W

450-750VA

(W)

300VA

13

7.STOP THE GENERATING SET

1. Disconnect the load from the generating set.

2. Turn off the breaker of the generating set.

3. Set the speed lever at "RUN" position, run

the generating set without load for about 3

minutes. Do not stop the engine suddenly,

otherwise the temperature will increase

abnormally, the nozzle will blocked and the

generating set will be damaged

Press down the stop lever

Concerning the electric starter, turn the key to "OFF ",

Turn the fuel cock lever to"S"position stop lever

With engine speed lever at STOP position

!

WARNING

If the engine keep on running even after the speed lever is placed at the

"STOP'position, either turn the fuel cock to the "CLOSE"position or loosen the nut of high pressure fuel pipe on the pump side to stop the engine.

Do not stop the engine with the decompression lever.

Do not stop the generating set with load. Stop it after the load removed.

8. PERIODIC CHECK AND SERVICE

Periodic check and service are very important for keeping the engine in good condition and durable. The chart below indicates what checks to make and when to make them.

14

!

WARNING

Shut off the engine before performing any service. If the engine must be run, make sure the area is well ventilated. The exhaust contains poisonous carbon monoxide gas.

After the generating set has been used, clean it immediately with a cloth to prevent corrosion and to remove sedimenh.

Interals

Item

Check and refill fuel oil

Drain out fuel oil

Check and refill engine oil

Check for oil leakage

Check and tighten fastening parts

Every day

First month

or 20 Hrs

Third month

or 100 Hrs sixth month or 500 Hfs

Every year or

1000 Hrs

Tighten the

Cylinder head

bolts

Replace engine oil

(First time) (Secondtime)

Clean engine oil filter

(Replace if necessary

Replace air cleaner element

(Service more frequently when

used in dusty areas) (Replace)

Clean fuel oil filter

(Replace)

Check fuel injection pump

Check nozzle

Check fuel pipe

(Replace if necessary)

Adjust clearance of intake/ exhaust valves

Grind intake/exhaust valves

Replace piston ring

Check battery electrolyte

Check carbon brush and slip ring

Check insulation resistance

Fisrt time)

Every month

The generating set has been stored more than lOdays

Note:" " indicates that special tools are required, please contact with AMICO agent.

15

8.1 Replace engine oil

Remove the oil filler cap. Remove the drain plug and drain the old oil while the engine is still warm. The plug is located on the bottom of the cylinder block. Tighten the drain plug and refill with the recommended oil.

Drain plug

Oil fillercap/Dipstick

8.2 Clean the engine oil filter

Cleaning time

Every 6 months or 500 hours

Replace if necessary

Drain plug

Oil filter

8.3 Replace the air cleaner element

Do not clean the air cleaner element with detergent.

Replace time

Every 6 months or

500 hours

Elelment

!

CAUTION

Never run the engine without the element or with a defective element.

8.4 Clean and replace fuel oil filter

The fuel oil filter also has to be cleaned regularly to insure maximum engine output.

Clean time

Replace time

Every 6 months or 500 hfs

Every year or 1000 hrs

16

1. Drain out the fuel from the fuel tank.

Loosen the three small screws and remvoe the fuel filter

2. Drain out the fuel from the fuel tank.Screw off the small screw of the fuel cock

and pull out the filter from the filler port.

3. Wash the filter thoroughly with diesel fuel.Loosen the fastening nut, bottom cover

and delivery discs for cleaning the deposit carbon.

8.5 Tighten cylinder head bolt

Tightening the cylinder head bolt requires a special tool. Do not try yourself. Contact with AMICO agent.

8.6 Check the injection nozzle and fuel injection pump

1. Adjust the clearance of the intake/exhaust valves,

2. Grind the intake/exhaust valves.

3 Replace the piston ring.

All these operation require special tools and skills, contact with your AMICO agent.

!

WARNING

Do not perform the injection nozzle test near an open fire or any other kind of fire. The fuel spray may ignite. De not expose bare skin to the fuel spray The fuel may penetrate the skin and cause injury to the body. Always keep your body away from the nozzle.

17

8.7 Check the battery and charge the battery

1.when you install it,frist check batteryís polarity if it

is same with generatorís anode &cathode line,check

volt if it is 12.3V,otherwise must electricize,

2.every month check volt if it is right,free charge

maintenance batteryís charge,volt is 13.5V-14.5v

3.check electric systerm if it have creepage,otherwise

damage battery,

4.if batteryís volt is not enough,electrica energy is low,please remove of battery and

electricize, on time,only have 5-6hours is ok,

5.battery put on the place of low temperature,dryness,aeration,clean,three month or

six month must need electricize,

!

WARNING

The battery electrolyte contains sulfuric acid. Protect your eyes, skin and clothing. In case of contact, flush thoroughly with water and get prompt medical attention, especially if yur eyes are affected.

The battery exhaust hydrogen gas, which can be highly explosive. Do not smoke or allow flames or sparks near the battery, especially during charging.

8.8 Check the generating set carbon brush and slip ring

Often check the generating set carbon brush and slip dng. Readjust if there is spark.

9. LONG-TERM STORAGE

If store the generating set for long periods,

make the following preparations.

1. Operate the engine for about 3 minutes

and then stop.

2. Stop the engine. Drain the engine oil while

the engine is still warm and fill with fresh

oil.

Oil fillercap/distick

Drain plug

18

3. Remove the screw plug on the cylinder head cover and refill 2cc engine oil, then

put the plug in place,

4. Turn the engine 2~3 seconds with the decompression lever set at the non-com-

pression position, and the starting key at the "START" position.( (Do not start the

engine.)

5. Pull the decompression lever up. Pull the recoil starter slowly. Stop when you feel

resistance.( at this position, both intake/exhaust valves are closed to prevent the

engine from the rust.)

6. Wipe off the oil and dirt from the engine and store in a dry place

10.TROUBLESHOOTING AND REMEDY

The diesel engine can not start

19

The generati n g s e t c a n not generate

11.DETAIL DIAGRAM

20

21

Number

25

26

27

28

29

20

21

22

23

24

16

17

18

19

13

14

15

33

34

35

36

30

31

32

42

43

44

45

37

38

39

40

41

6

7

4

5

1

2

3

8

9

10

11

12

Part Description

Silencer Cover

Silencer Bend

Left Board

Back Door

Fixing Sleeve For Observing Bore

Fixing Sleeve For Input Of Fule Tank

Main Cover

Swich

Air Filter Baffle

Accelerator Electomagnet

Right Board

Output Panel Assembly

Cover Of Observing Bore For Air Filter

Cover Of Fuel Tank

Buoy For Oil Leverl Indication

Fuel Tank

Lining

Shock Absorption Mat

Clip

Clip

Fuel Inlet Pipe

Fuel Filter Assembly

Fuel Inlet Pipe

Fuel Leak-off Pipe

Cover Of U Type Chamfer

U Type Chamfer

Support Of U Type Chamfer

Output pipe

Gasket Of Silencer

Upper Silencer

Low Silencer

Back Cover Of Alternator

Bracket

Shock Absorption Mat

Tow Structure Of Accelerator

Electomagnet

Bracket Of Electomagnet

Long Cover

Chassis

Rolling Wheel On Chassis

Flat Key

Pin

Motherboard Of Accumulator

Accumulator

Bolt

Quantity

1

4

1

1

4

1

1

4

4

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

22

Part Number

AH4000LN019

AH4000LN020

AH4000LN021

AH4000LN022

AH4000LN023

AH4000LN024

AH4000LN025

AH4000LN026

AH4000LN027

AH4000LN028

AH4000LN029

AH4000LN030

AH4000LN031

AH4000LN032

AH4000LN033

AH4000LN034

AH4000LN035

AH4000LN036

AH4000LN037

AH4000LN038

AH4000LN039

AH4000LN040

AH4000LN041

AH4000LN042

AH4000LN043

AH4000LN044

AH4000LN045

AH4000LN001

AH4000LN002

AH4000LN003

AH4000LN004

AH4000LN005

AH4000LN006

AH4000LN007

AH4000LN008

AH4000LN009

AH4000LN010

AH4000LN011

AH4000LN012

AH4000LN013

AH4000LN014

AH4000LN015

AH4000LN016

AH4000LN017

AH4000LN018

Number

C

D

E

57

58

A

B

F

G

H

I

J

K

L

M

N

50

51

52

53

54

55

56

46

47

48

49

Part Description

Pressingplate Of Accumulator

Pulling Wire For Throttle

Pulling Wire For Turn-off

Alternator

Output Wind Leading Shaft

Manostat

Gasket Of Output Bore

Cf Series Disel Engine

Pulling Role For Accelerator

Intake Wind Leading Shaft

Pressing Plate Of High Pressure Fuel Pipe

Shock Preventing Mat

Shock Preventing Holder

M6*16 Bolt,Flat Key

M6*8 Bolt

M4*8 Bolt

M6*12 Bolt

M10*45 Bolt

M6*16 Bolt

M8*25 Bolt

M6*12 Bolt

M5*8 Bolt

M6 Nut

M8 Nut*Flat Spring Washer

M10 Nut*Flat Spring Washer

M5*12 Bolt

M6*22 Bolt

Quantity

4

4

4

5

17

1

1

41

4

4

12

2

2

12

2

6

1

1

1

1

1

1

1

1

1

1

1

Part Number

AH4000LN046

AH4000LN047

AH4000LN048

AH4000LN049

AH4000LN050

AH4000LN051

AH4000LN052

AH4000LN053

AH4000LN054

AH4000LN055

AH4000LN056

AH4000LN057

AH4000LN058

AH4000LN059

AH4000LN060

AH4000LN061

AH4000LN062

AH4000LN063

AH4000LN064

AH4000LN065

AH4000LN066

AH4000LN067

AH4000LN068

AH4000LN069

AH4000LN070

AH4000LN071

AH4000LN072

23

12.PANEL DETAIL DIAGRAM

24

Number

8

9

10

11

12

13

14

6

7

4

5

1

2

3

15

16

17

18

19

20

21

Part Description

Panel

M6X12 Bolt

Starter Switch

M4X30 Bolt

3 Prong Socket

M4X15 Bolt

M5X25 Bolt

Positive DC Port

Negative DC Port

Grounded Bolt

Integrating

DC Fuse

Breaker

Breaker Bracket

4 Prong Socket

Current Adjusting Switch

Oil Alert Lamp

Voltmeter

Wiring Harness

Box

Hour meter

Quantity

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

4

2

1

6

2

2

Part Number

AH4000LN073

AH4000LN074

AH4000LN075

AH4000LN076

AH4000LN077

AH4000LN078

AH4000LN079

AH4000LN080

AH4000LN081

AH4000LN082

AH4000LN083

AH4000LN084

AH4000LN085

AH4000LN086

AH4000LN087

AH4000LN088

AH4000LN089

AH4000LN090

AH4000LN091

AH4000LN092

AH4000LN093

25

13.WIRING DIAGRAM

26

Limited Warranty

AMICO provides a one-year limited warranty for AMICO generators. All products covered by this limited warranty which are used in commercial applications are warranted to be free of defects in material and workmanship for 90 days from the date of original purchase. AMICO warrants to the original purchaser that the alternator and engine for its portable generator will be free from the defects in materials or workmanship for the items and period set forth below from the date of original purchase.

During warranty period, AMICO will repair or replace any part that, upon examination by AMICO, is found to be defective under normal use and service. Starting batteries are not warranted by

AMICO. All transportation cost under warranty including return to the factory if necessary, are to be prepaid by the purchaser. All decisions of AMICO with regard to this limited warranty shall be final.

This warranty does not cover:

1.Merchandise sold as reconditioned, used as rental equipment, or floor or display models.

2.Merchandise that has become damaged or inoperative because of ordinary wear, misuse, cold, heat, rain, excessive humidity, freeze damage, use of improper chemicals, negligence, accident, over loading, over speeding, improper maintenance, the use of accessories or attachments not recommended by AMICO, or unauthorized repair or alterations.

3.Expendable parts or accessories supplied with the product which are expected to become inoperative or unusable after a reasonable period of use.

4.Any incidental, indirect or consequential loss, damage, or expense thatmay result from any defects, failure or malfunction of the products is not covered by this warranty.

For service, please e-mail to or fax to 562-908-1899, Warranty service can be performed only by

AMICO authorized service facility. This warranty will not apply to service at any other facility. At the time of requesting warranty service, evidence of original purchase date must be presented.

27

PRODUCT REGISTRATION CARD

For more efficient customer service, please fill out the information below and mail to our produce Warranty and Registration Division:

Amico International Corp.

4825 Gregg Road,

Pico Rivera, CA 90660, U.S.A

Tel: 562-908-0088 Fax: 562-908-1899

Website: www.amicousa.com

Model No.

Engine Serial No.

Purchase Date. / /

Purchased from:

Name

Address

[ ] Retail location [ ] Private Consumer [ ] Other

Telephone w/area code Purchase Price

Purchased: [ ] NEW or [ ] USED

Consumer information :

Name Telephone w/area code

Address Suite or Apt No.

City State Zip Code

Country

Are you a: [ ] Business or [ ] Residence

Product Usage Information :

How often will you use this product?

[ ] Everyday [ ] Periodically

[ ] Emergency use only [ ]Other

What type of application will you use this produce in ?

[ ]Heavy Commercial [ ]Moderate Commercial

[ ]Light Commercial [ ] Tradeshows

[ ] Heavy residential [ ] Moderate Residential

[ ]Light Residential [ ]Camping, backpacking

[ ]Other

IMPORTANT I NFORIJAT I ON

It is critical to your warranty that the original point of sales receipt be retained by current consumer, and in order to comply with our product Warranty Statement you must return this registration card within 15 days of original purchase. Product warranty is valid from original date of purchase.

28

List for comments from users

Name of user

Address of user

Place of purchase

Packaging conditions

Operating conditions

Parts Conditions

Malfunction problem

Opinions or suggestions

Note: Please mail the above card to:

Amico International Corp.

4825 Gregg Road,

Pico Rivera, CA 90660, U.S.A

Tel: 562-908-0088 Fax: 562-908-1899

Website: www.amicousa.com

Date of Manufacture

Model Number

Occupation

Appendix:

1. Attached list of tools, fittings, and subassemblies

Order No.

1

Name Qty Remarks

4-Stroke Air-cooled Diesel Generator Set

1

2 Kit 1

3 Plastic cover 1

4

Plug and power supply

1

2. Attached technical documents

Order No.

Name Qty Remarks

1 1

2

3

4

5

Air cooled diesel generator manual

Diesel engine instruction manual

Diesel engine parts listing

Certificate of Quality

Packing List