SAJ R6 User Manual
PDF
Dokumen
Iklan
Iklan
V1.3 R6-15~50K-T2/T3/T4-32 1. SAFETY PRECAUTIONS ----------01 1.1 Scope of Application-----02 1.2 Safety-----02 1.2.1 Safety Instruction-----02 1.2.2 Explanations of Symbols-----03 4. ELECTRICAL CONNECTION----------21 4.1 Safety Instruction -----22 4.2 Speci cations for Electrical Inte ace-----22 4.3 AC Connection-----24 4.4 DC Side Connection-----26 1.2.3 Safety Instructions-----04 4.5 Ea h Fault Alarm-----27 4.6 Communication Connection-----28 2. PRODUCT OVERVIEW----------05 5. DEBUGGING INSTRUCTIONS----------29 2.1 Speci cation for Product Model-----07 5.1 Introduction of HMI-----30 2.2 Appearance-----07 5.2 Monitoring Operation-----31 2.3 Datasheet-----09 5.2.1 APP Introduction-----31 3. INSTALLATION INSTRUCTION----------13 3.1 Safety Instructions-----14 3.2 Pre-installation Check-----14 3.3 Determination the Installation method and Position-----15 3.4 Mounting Procedure-----18 5.2.2 Local Connection-----32 5.2.3 Account Login-----34 5.2.4 Inve er Setting Review-----36 5.2.5 Remote Monitoring-----36 5.3 Expo Limit Setting-----37 5.4 Self-test-----39 5.5 Setting Reactive Power Control-----41 6. FAULT CODE & Troubleshooting----------45 7. RECYCLING & DISPOSAL----------49 R6-15K-T2-32, R6-17K-T2-32, R6-20K-T2-32, R6-22K-T2-32, R6-25K-T2-32-B, R6-25K-T3-32, R6-25K-T3-32-B, R6-33K-T3-32 , R6-36K-T3-32, R6-36K-T4-32, R6-25K-T2-32 R6-30K-T3-32, R6-30K-T3-32-B R6-40K-T4-32, R6-50K-T4-32 R6 – XK – TX – 32 - B 5 5 B indicates this model is ONLY applicable to Belgium. Figure 2.2 Dimensions of R6-25~36K-T3-32,R6-25K/30K-T3-32-B Figure 2.2 Figure 2.4 Dimensions of Dimensions of R6-15~25K-T2-32,R6-25K-T2-32-B R6-36K/40K/50K-T4-32 R6-15K/17K/20K/22K/25K-T2-32,R6-25K-T2/T3-32-B Model R6-15K-T2-32 R6-17K-T2-32 R6-20K-T2-32 R6-22K-T2-32 R6-25K-T2-32-B R6-25K-T2-32 R6-25K-T3-32-B Mode Anti-islanding Protection Input (DC) AFCI Protection Max. PV Array Power [Wp]@STC 1100 MPPT Voltage Range [V] 180-1000 AC Connection Nominal Input Voltage [V] 600 DC Connection Sta -up Voltage [V] 200 Display Max. Sho -Circuit Current[A] R6-20K-T2-32 R6-22K-T2-32 R6-25K-T2-32-B 32/32 32/32/32 38.4/38.4 Number of MPP Trackers 2 38.4/38.4/38.4 3 Number of Strings per MPP Tracker 2/2 2/2/2 Communication Po Communication Mode Load Monitoring Optional Terminal Block MC4 LED+APP (Bluetooth) Rs232(USB)+RS485(RJ45)+DRM(RJ45) Wi-Fi/Ethernet/4G 24/7 (Optional) Transformerless Rated AC Output Power [W] 15000 17000 20000 22000 25000 25000 25000 Nighttime Power Consumption [W] Max. AC Output Power [VA] 16500 18700 22000 24200 25000 27500 25000 Operating Temperature Range Rated AC Output Current [A]@230Vac 21.7 24.6 29.0 31.9 36.2 36.2 36.2 Cooling Method Intelligent fan Cooling Max. AC Output Current [A] 25.0 28.3 33.3 36.7 37.9 41.7 37.9 Ambient Humidity 0%~100% non-condensing Nominal AC Grid Frequency/ Range [Hz] Total Disto ion Harmonic [THDi] Power Factor Feed-in Phases/AC Connection Phases 3+N+PE, 220/380, 230/400, 240/415; 180-280/312-485 50, 60/44-55, 54-65 < 3% 0.8 leading~0.8 lagging 3/3 Max. Operating Altitude [m] <0.6 -40℃~+60℃ 4000m (>3000m power derating) Noise [dBA] <50 Ingress Protection IP65 Mounting Dimensions [H*W*D] [mm] Weight [kg] E ciency R6-25K-T3-32-B General Data Topology Output (AC) Nominal AC Voltage/ Range [V] R6-25K-T2-32 AFD Inte ace Max. Input Voltage [V] Max. Input Current [A] R6-15K-T2-32 R6-17K-T2-32 Rear Panel 409*558*234.5 473*659.4*240 22.5 35.5 Max. E ciency 98.8% Warranty [Year] Refer to the warranty card Euro E ciency 98.5% Ce i cations IEC/EN62109-1/2, EN61000-6-1/2/3/4, IEC61683, IEC60068-2, IEC62116, IEC61727, PEA/MEA, VDE0126-1-1/A1, CEI 0-21, VDE-AR-N 4105, AS/NZS4777.2, CQC NB/T 32004, G98/G99, NBR 16149, NBR 16150, C10/11, RD1669, UNE206006, UNE206007, EN50438 Protection DCI Monitoring Integrated GFCI Monitoring Integrated Grid Monitoring Integrated AC Grounding Detection Integrated AC Sho -Circuit Protection Integrated DC Insulation Resistance Detection Integrated DC Surge Protection Type III AC Surge Protection Type III R6-25/30K/33K/36K-T3-32, R6- 36K/40K/50K-T4-32 R6-30K-T3-32-B Model R6-25K-T3-32 R6-30K-T3-32-B R6-30K-T3-32 R6-33K-T3-32 R6-36K-T3-32 R6-36K-T4-32 R6-40K-T4-32 R6-50K-T4-32 Input (DC) Max. PV Array Power [Wp]@STC 37500 45000 45000 49500 54000 Max. Input Voltage [V] 1100 MPPT Voltage Range [V] 180-1000 Nominal Input Voltage [V] 600 54000 60000 75000 Max. Input Current [A] Max. Sho -Circuit Current[A] Number of MPP Trackers 32/32/32/32 38.4/38.4/38.4 3 2/2/2 2/2/2/2 33000 36000 36000 40000 50000 Max. AC Output Power [VA] 27500 30000 33000 36300 39600 39600 44000 50000 Rated AC Output Current [A]@230Vac 36.2 43.5 43.5 47.8 52.2 52.2 58 72.5 Max. AC Output Current [A] 41.7 45.5 50 55 60 60 66.7 75.8 50, 60/44-55, 55-65 <3% 0.8 leading~0.8 lagging Wi-Fi/Ethernet/4G 24/7 (Optional) Topology 30000 3+N+PE , 220/380, 230/400, 240/415; 180-280/312-485 Rs232(USB)+RS485(RJ45)+DRM(RJ45) General Data 30000 Power Factor MC4 LED+APP (Bluetooth) Load Monitoring 4 25000 Total Disto ion Harmonic [THDi] Terminal Block Communication Mode Rated AC Output Power [W] Nominal AC Grid Frequency/ Range [Hz] Optional Inte ace Communication Po Output (AC) Nominal AC Voltage/ Range [V] AFCI Protection Display 38.4/38.4/38.4/38.4 Transformerless Nighttime Power Consumption [W] <0.6 Operating Temperature Range -40℃~+60℃ Cooling Method Intelligent fan Cooling Ambient Humidity 0%~100% non-condensing Max. Operating Altitude [m] 4000m (>3000m power derating) Noise [dBA] <50 Ingress Protection IP65 Mounting Rear Panel 3/3 Dimensions [H*W*D] [mm] Weight [kg] 35.5 Max. E ciency 98.8% Warranty [Year] Refer to the warranty card Euro E ciency 98.5% Feed-in Phases/AC Connection Phases E ciency Protection DCI Monitoring Integrated GFCI Monitoring Integrated Grid Monitoring Integrated AC Grounding Detection Integrated AC Sho -Circuit Protection Integrated DC Insulation Resistance Detection Integrated DC Surge Protection Type II AC Surge Protection Type III R6-50K-T4-32 AFD DC Connection 32/32/32 Number of Strings per MPP Tracker R6-25K-T3-32 R6-30K-T3-32-B R6-30K-T3-32 R6-33K-T3-32 R6-36K-T3-32 R6-36K-T4-32 R6-40K-T4-32 Anti-islanding Protection AC Connection 200 Sta -up Voltage [V] Model Ce i cations 473*659.4*240 37 IEC/EN62109-1/2, EN61000-6-1/2/3/4, IEC61683, IEC60068-2, IEC62116, IEC61727, PEA/MEA, VDE0126-1-1/A1, CEI 0-21, VDE-AR-N 4105, AS/NZS4777.2, CQC NB/T 32004, G98/G99, NBR 16149, NBR 16150, C10/11, RD1669, UNE206006, UNE206007, EN50438 37.5 3.1 Safety Instructions 3.2 Pre-installation Check 3.2.1 Check the Package Although SAJ’s inve ers have thoroughly tested and checked before delive , it is unce ain that the inve ers may su er damages during transpo ation. Please check the package for any obvious signs of damage, and if such evidence is present, do not open the package and contact your dealer as soon as possible 3.2.2 Scope of Delive Please contact after sales if there is missing or damaged components. Rear Panel*1 (T2 series) Inve er*1 Screw-secured bracket* 4 Big gasket* 4 M6*50 * 4 Terminals*5 M4*12 screw*8 (T2 series) Communication module*1 (Optional) M4*10 screw*8 (T3 series) (T4 series) M5*12 screw (T2 series*1) (T3 series*2) (T4 series*2) Rear Panel*1 (T3 series) (T4 series) AC waterproof cover*1 PV connector (T2 series*4) (T3 series*6) (T4 series*8) Documents The documents include the user manual, quick installation guide and packaging list. 3.3 Determine the installation method and position Installation Environment Requirements The installation environment must be free of in ammable or explosive materials. Install the device away from heat source. Do not install the device at a place where the temperature changes extremely. Keep the device away from children. Do not install the device at daily working or living arears, including but not limited to the following areas: bedroom, lounge, living room, study, toilet, bathroom, theater and attic. When installing the device at the garage, please keep it away from drive way. Keep the device from water sources such as taps, sewer pipes and sprinklers to prevent water seepage. The product is to be installed in a high tra c area where the fault is likely to be seen. Note: When installing outdoors, the height of the device from the ground should be considered to prevent the device from soaking in water. The speci c height is determined by the site environment. R6-36K/40K/50K-T4-32 R6-25K/30K-T3-32-B 3.4 Mounting Procedure ,R6-25K-T2-32-B ,R6-25K-T2-32-B R6-36K/40K/50K-T4-32 R6-25K/30K-T3-32-B R6-25K-T2-32-B R6-15~25K-T2-32,R6-25K-T2-32-B R6-25~36K-T3-32,R6-25K/30-T3-32-B R6-36~50K-T4-32 R6-25K/30K-T3-32-B R6-36K/40K/50K-T4-32 External AC Circuit Breaker and Residual Current Device Please install a 4P circuit breaker to ensure the inve er is able to disconnect from grid safely. The inve er is integrated with a RCMU, however, an external RCD is needed to protect the system from tripping, either type A or type AC RCD is compatible with the inve er. The integrated leakage current detector of inve er is able to detect the real time external current leakage. When a leakage current detected exceeds the limitation the inve er will be disconnected from grid quickly, if an external leakage current device is connected, the action current should be 300mA. Table 4.3 Recommended AC circuit breaker speci cations Type Recommended AC circuit breaker speci cations R6-15~25K-T2-32,R6-25K-T2-32-B 40A R6-25~36K-T3-32,R6-25K/30K-T3-32-B 60A R6-36~50K-T4-32 100A 4.6 Communication Connection 4.5 Ea h Fault Alarm 6 This inve er complies with IEC 62109-2 clause 13.9 for ea h fault alarm monitoring. If an Ea h Fault Alarm occurs, the second LED indicator will be lit up until the error being solved and inve er functioning properly. Note:The inve er cannot be used with functionally ea hed PV Arrays. 5.2.2 Local connection Step 1: Open eSAJ APP and click on the dot icon on the top right corner Step 2: Select “Local Connection” Step 3: Enter password “123456” ● R6 series products could be monitored through eSolar APP. ● This equipment is standardly equipped with a USB inte ace which could transfer AIO3/4G module and Wi-Fi module to monitor running state of the equipment. Step 4: Click on “Bluetooth” and activate the Bluetooth function on your phone, then click on “Next” Step 5: Choose your inve er according to your inve er SN's tail numbers Step 6: Click on the inve er to enter inve er setting Step 7: Select the corresponding count eSAJ could achieve communication with the equipment via Bluetooth, Cellular network and Wi-Fi and it is an APP for nearby and remote monitoring. Download eSAJ Home APP iOS system: search for “eSAJ Home” in App Store and download this App.. Android system: search for “eSAJ Home” in Google play and download this App. Account---Please use the installer account to login. and grid code for 5.2.3 Account Login Step 1: Log in to eSAJ Home, if you do not have an account, please register rst. Step 2: Go to the “Tool” inte ace and select “Remote Con guration” Step 3: Click on “Bluetooth” and activate the Bluetooth function on your phone, then click on “Next” Step 4: Choose your inve er according to your inve er SN's tail numbers Step 5: Click on the inve er to enter inve er setting Step 6: Select the corresponding count and grid code for 5.2.4 Inve er Setting Review After commissioning, the device info including device basic info, running info and event info can be viewed. Count and grid code can be viewed from initial setting. 5.2.5 Remote Monitoring Connect the internet via the eSolar/4G/WiFi module, and upload the inve er data onto the se er and customers could monitor running information of the inve er remotely via the eSolar Web Po al or their mobile customer terminals. 5.3 Expo 5.3.1 Limit Setting APP Setting Enter the main page of local connection and click on Expo limitation setting, enter the password “201561”. Main Mete Solar inve er On-grid Load There are two methods to control the expo limit, the two methods are alternative to each other. Method1: Expo limitation setting is to control the e xpo elec tricity to the grid. Method 2: Generation limit is to control the electricity generated by the inve er. CT installation: The arrow direction points to the inve er Sma Meter Figure 5.4 Expo limit wiring schematic 37 38 5.4 Self-test (For Italy) Step 3: Sta Self-test You can choose self-test item required. Individual self-test time is approx. 5 minutes. All self-test time is approx. 40 minutes. After the self-test is completed, you can save the test repo . If self-test is Italian Standard CEI0-21 requires a self-test function for all inve er that connected to utility failed, please contact with SAJ or your inve er supplier. grid. During the self-testing time, inve er will check the reaction time for over frequency,under frequency, ove oltage and unde oltage. This self-test is to ensure the inve er is able to disconnect from grid when required. If the self-test fails, the inve er will not able to feed into the grid. Step 1: Connect a communication module (Wi-Fi/ 4G/ Ethernet) with inve er (connection procedure can refer to eSolar Module Quick Installation Manual) Step 2: Select Italy for Count and choose your corresponding Grid Code from Initial Setting. 39 40 5.5 Setting Reactive Power Control Fixed Reactive Power Mode (For Australia) 5.5.1 Setup Fixed Power Factor Mode & Fixed Reactive Power Mode Fixed Power Factor Mode Step 1: Select Inductive Adjustment Var or Capacitive Var according to your local grid regulation. The power range is from -60%Pn~ 60%Pn. Step 1: Select Power Adjustment and enter password “201561”. Step 2: Select Capacitive Power Factor or Inductive Power Factor according to your local grid regulation. The power factor range is from 0.8 leading ~ 0.8 lagging. 41 42 5.5.2 Setup V-Watt and Volt-Var mode Setting procedure: This inve er complies with AS/NZS 4777. 2020 for power quality response modes. The inve er satis es di erent regions of DNSPs' grid connection rules requirements for voltwatt and volt-var Settings. e.g.: AS4777 series setting as below Fig 5.5&5.6. 1.AS4777 grid compliance has been set during production, please select corresponding grid compliance according to state regulation during installation. You can choose a state regulation compliance with your local grid via eSAJ Home. 2. Log in to eSAJ Home , click “Local Connection”, for connection procedure please refer to chapter 5.2.2 Nearby monitoring. 3. Click “V-Watt/V-Var” to enter DNSPs settings, choose a suitable state regulation from the drop down list. Figure 5.5 Cu e for a Volt-Watt response mode (AS4777 Series) Figure 5.6 Cu e for a Volt-Var control mode (AS4777 Series) 43 44 Troubleshooting Code Fault Information 1 Master Relay Error 2 Master EEPROM Error 3 Master Temperature High Error 4 Master Temperature Low Error 5 Lost Communica tion M<->S 6 GFCI Device Error 7 DCI Device Error 8 Current Sensor Error 9 Master Phase1 Voltage High 10 Fault Information 40 Master Self -Test Failed 41 Master HW Inv Current High 42 Master AC SPD Error 43 Master DC SPD Error 44 Master Grid NE Voltage Error 45 Master Fan1 Error 46 Master Fan2 Error 47 Master Fan3 Error 48 Master Fan4 Error Master Phase1 Voltage Low 49 Lost Communication between Meter 11 Master Phase2 Voltage High 50 Lost Communication between M< ->S 12 Master Phase2 Voltage Low 13 Master Phase3 Voltage High 51 Lost Communication between inve er and Grid Meter 14 Master Phase3 Voltage Lo w 52 HMI EEPROM Error Grid Voltage 10Min High 53 HMI RTC Error O Grid Output Voltage Low 54 BMS Device Error 17 O Grid Output Sho Circuit 55 BMS Lost.Conn 18 Master Grid Frequency High 56 CT Device Err Master Grid Frequency Low 57 AFCI Lost Err Lost Com. H< ->S Err 15 16 19 45 Code 21 Phase1 DCV High 58 22 Phase2 DCV High 61 Slave Phase1 Voltage High 23 Phase3 DCV High 62 Slave Phase1 Voltage Low 24 Master No Grid Error 63 Slave Phase2 Voltage High 27 GFCI Error 64 Slave Phase2 Voltage Low 28 Phase1 DCI Error 65 Slave Phase3 Voltage High 29 Phase2 DCI Error 66 Slave Phase3 Voltage Low 30 Phase3 DCI Error 67 Slave Frequency High 31 ISO Error 68 Slave Frequency Low 32 Bus Voltage Balance Error 73 Slave No Grid Error 33 Master Bus Voltage High 74 Slave PV Input Mode Error 34 Master Bus Voltage Low 75 Slave HW PV Curr High 35 Master Grid Phase Lost 76 Slave PV Voltage High 36 Master PV Voltage High 77 Slave HW Bus Volt High 37 Master Islanding Error 81 Lost Communication D< ->C 38 Master HW Bus Voltage High 83 Master Arc Device Error 39 Master HW PV Current High 84 Master PV Mode Error Master and 46 Code Fault Information 85 Authority expires 86 DRM0 Error 87 Master Arc Error 88 Master SW PV Current High Please contact your supplier for troubleshooting and remedy 47 48 49 50 ">
/
Unduh
Hanya pengingat ramah. Anda dapat melihat dokumen di sini. Tetapi yang paling penting, AI kami telah membacanya. Ia dapat menjelaskan hal-hal kompleks dengan istilah sederhana, menjawab pertanyaan Anda dalam bahasa apa pun, dan membantu Anda menavigasi dengan cepat bahkan dokumen terpanjang atau paling rumit.
Iklan