SAJ H2 User Manual
PDF
Documento
Pubblicità
Pubblicità
H2 Series H2 Series SAJ HYBRID SOLAR INVERTER Tel: (86)20 66608588 GUANGZHOU SANJING ELECTRIC CO.,LTD Fax: (86)20 66608589 Web: www.saj-electric.com Add: SAJ Innovation Park,No.9, Lizhishan Road,Science City, Guangzhou High-tech Zone , Guangdong, P.R.China V0.2 USER MANUAL H2-5~10K-S3 H2 Series Preface Thank you for choosing SAJ products. We are pleased to provide you first-class products and exceptional service. This manual includes information for installation, operation, maintenance, trouble shooting and safety. Please follow the instructions of this manual so that we can ensure delivery of our professional guidance and wholehearted service. Customer-orientation is our forever commitment. We hope this document proves to be of great assistance in your journey for a cleaner and greener world. Please check for the latest version at www.saj-electric.com. Guangzhou Sanjing Electric Co., Ltd. H2 Series TABLE OF CONTENTS 4.2 Installation Method and Position ...................................................................................................................... 15 4.2.1 Installation Position and Clearance ........................................................................................ 15 4.2.2 Mounting Method ....................................................................................................................... 16 4.3 Mounting Procedure ............................................................................................................................................. 17 4.3.1 Installation Tools.......................................................................................................................... 17 4.3.2 Mounting Procedure................................................................................................................... 18 5. ELECTRICAL CONNECTION .................................................................................................................21 5.1 Additional Grounding Cable ............................................................................................................................... 22 5.2 AC Grid Wire and Backup Output Connection .............................................................................................. 23 5.2.1 Multiple Inverter Combinations ............................................................................................... 25 1. SAFETY PRECAUTIONS .......................................................................................................................... 1 5.3 PV Side Connection............................................................................................................................................... 26 1.1 Scope of Application ...............................................................................................................................................2 5.3.1 PV Connector Assembly ............................................................................................................ 27 1.2 Safety Instructions ...................................................................................................................................................2 5.4 Communication Connection ............................................................................................................................... 30 1.3 Target Group .............................................................................................................................................................2 5.5 Connection Battery COMM Cable ..................................................................................................................... 31 5.6 Connecting Battery Power Cable ...................................................................................................................... 32 2. PREPARATION ......................................................................................................................................... 3 5.7 Battery Connection ............................................................................................................................................. 32 2.1 Safety Instructions ...................................................................................................................................................4 5.8 System Connection ............................................................................................................................................... 35 2.2 Explanations Of Symbols .......................................................................................................................................5 5.9 System Connection Diagram .............................................................................................................................. 37 5.10 AFCI (Optional) .................................................................................................................................................... 37 3. PRODUCT INFORMATION ...................................................................................................................... 7 3.1 Application Scope of Products .............................................................................................................................8 6. COMMISSIONING ...................................................................................................................................39 3.2 Specification for Product Model ..........................................................................................................................8 6.1 Start Up and Shut Down the Energy Storage System ................................................................................ 40 3.3 Overview of Product ...............................................................................................................................................9 6.1.1 Start Up .......................................................................................................................................... 40 3.4 Terminals Description .............................................................................................................................................9 6.1.2 Shut Down ..................................................................................................................................... 40 3.5 Datasheet ................................................................................................................................................................ 11 6.2 Introduction of Human-computer Interface .................................................................................................. 40 6.3 Commissioning ....................................................................................................................................................... 42 4. INSTRUCTIONS FOR INSTALLATION..................................................................................................13 6.4 eSAJ APP Connection ........................................................................................................................................... 42 4.1 Unpacking and Inspection .................................................................................................................................. 14 6.4.1 Account Login .............................................................................................................................. 42 4.1.1 Checking the Package ............................................................................................................... 14 6.4.2 Local Connection ......................................................................................................................... 44 4.1.2 Scope of Delivery ........................................................................................................................ 14 6.4.3 Inverter Setting Review ............................................................................................................. 46 H2 Series 6.5 Working Modes ..................................................................................................................................................... 47 6.5.1 Selecting Working Modes Procedures .................................................................................. 47 6.5.2 Working Modes Instruction ...................................................................................................... 47 6.6 Export Limit Setting ............................................................................................................................................. 48 6.6.1 APP Setting ................................................................................................................................... 49 6.7 Self-test (For Italy)................................................................................................................................................ 50 6.8 Setting Reactive Power Control (For Australia) ............................................................................................ 52 6.8.1 Setup Fixed Power Factor Mode ............................................................................................ 52 6.8.2 Setup V-Watt and Volt-Var Mode ......................................................................................... 53 7. TRANSPORTATION and DISPOSAL ....................................................................................................57 7.1 Transportation ....................................................................................................................................................... 58 7.2 Recycling and Disposal ........................................................................................................................................ 58 8. ROUTINE MAINTENANCE.....................................................................................................................59 9. TROUBLESHOOTING and WARRANTY ..............................................................................................61 H2 Series 1.1 Scope of Application 1. This User Manual describes instructions and detailed procedures for installing, operating, maintaining, and troubleshooting of the following SAJ products: H2-5K-S3; H2-6K-S3; H2-7K-S3; H2-8K-S3; H2-10K-S3 1.2 Safety Instructions DANGER · DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING ·WARNING indicates a hazardous situation which, if not avoided, can result in death or serious injury or moderate injury. CAUTION · CAUTION indicates a hazardous condition which, if not avoided, can result in minor or moderate injury. SAFETY PRECAUTIONS 1 NOTICE · NOTICE indicates a situation that can result in potential damage, if not avoided. 1.3 Target Group Only qualified electricians who have read and fully understood all safety regulations in this manual can perform installation and maintenance. Operators must be aware of the high-voltage device. 2 H2 Series 2.1 Safety Instructions 2. For safety, be sure to read all the safety instructions carefully prior to any works, and please observe the appropriate rules and regulations of the country or region where you installed the energy storage system. DANGER · There is possibility of dying due to electrical shock and high voltage. · Do not touch the operating component of the inverter; it might result in burning or death. · To prevent risk of electric shock during installation and maintenance, please make sure that all AC and DC terminals are plugged out. · Do not touch the surface of the equipment while the housing is wet, otherwise, it might cause electrical shock. · Do not stay close to the equipment while there are severe weather conditions including storm, lighting, etc. · Before opening the housing, the SAJ inverter must be disconnected from the grid and PV generator; you must wait for at least five minutes to let the energy storage capacitors completely discharged after disconnecting from power source. WARNING ·The installation, service, recycling and disposal of the inverters must be performed by qualified personnel only in compliance with national and local standards and regulations. ·Any unauthorized actions including modification of product functionality of any form may cause lethal hazard to the operator, third parties, the units or their property. SAJ is not responsible for the loss and these warranty claims. ·The SAJ inverter must only be operated with PV generator. Do not connect any other source of energy to the SAJ inverter. ·Be sure that the PV generator and inverter are well grounded in order to protect properties and persons. PREPARATION CAUTION ·The inverter will become hot during operation. Please do not touch the heat sink or peripheral surface during or shortly after operation. ·Risk of damage due to improper modifications. NOTICE ·The inverter is designed to feed AC power directly to the public utility power grid; do not connect AC output of the inverter to any private AC equipment. 3 4 H2 Series 2.2 Explanations of Symbols Symbol Description Dangerous electrical voltage This device is directly connected to public grid, thus all work to the battery shall only be carried out by qualified personnel. No open flames Do not place or install near flammable or explosive materials. Danger of hot surface The components inside the battery will release a lot of heat during operation. Do not touch metal plate housing during operating. Attention Install the product out of reach of children An error has occurred Please go to Chapter 7 “Troubleshooting” to remedy the error. This device shall NOT be disposed of in residential waste This battery module shall NOT be disposed of in residential waste CE Mark Equipment with the CE mark fulfills the requirements of the Low Voltage Directive and Electro Magnetic Compatibility. Recyclable 5 6 H2 Series 3.1 Application Scope of Products 3. H2 series is a hybrid photovoltaic inverter and it is applicable to both on-grid and off-grid solar systems. The energy generated by PV system will be fed to loads first, and then the surplus energy can charge the battery for later use, if there is still excess more energy, it will be exported to the grid. H2 inverter can significantly improve the self-consumption rate of solar energy and lower the dependency on grid. 3.2 Specification for Product Model H2 – XK – S3 ① ② ③ ① H2 represents for product name. ② XK represents rated energy XkW of inverter, for example, 5K means 5kW. PRODUCT INFORMATION 7 ③ S3 means single phase with 3MPPT 8 H2 Series 3.3 Overview of Product Code Name A DC Switch B DC Input C DC Input D DC Input E Battery Input F BMS/ CAN/ EMS/ METER/ DRM G CT/ Inverter Parallel port H Release Valve I 4G/ Wi-Fi J Ground Connection K Grid L Backup Table 3.1 Figure 3.1 Terminals description Dimensions of inverter 3.4 Terminals Description Figure 3.2 Electrical interface of H2 Inverter 9 10 H2 Series 3.5 Datasheet Model Model H2-5K-S3 H2-6K-S3 H2-7K-S3 H2-8K-S3 H2-10K-S3 7500 9000 10500 12000 15000 DC Input Max. PV Array Power [Wp]@STC Max. DC Voltage [V] 600 MPPT Voltage Range [V] 360 Start Voltage [V] 100 Max. DC Input Current [A] Max. Charging/Discharging Current [A] Integrated Anti-islanding Protection Integrated LiFePO4 AFCI Protection Optional 85~450 RSD Protection Optional Interface 8000 10000 Max. Apparent Power [VA] 5500 6600 7700 8800 10000 Rated Current [A] 21.7 26.1 30.4 34.8 43.5 Max. AC Output Current to Utility Grid [A] 25 30 35 40 45.5 Current Inrush[A] 150 Max. AC Fault Current[A] 130 75 88 100 100 L+N+PE, 220, 230, 240/180~280 50,60/45~55,55~65 MC4/D4(Optional) AC Connection Plug-in connector Battery Connection Quick connector Display Communication <3% L+N+PE, 220, 230, 240/180~280 Rated Input Frequency [Hz] 50,60 Operating Temperature Range Natural Convection Ambient Humidity 0-100% Non-condensing 52.2 60.9 69.6 69.6 Max. Output Power [VA] 5000 6000 7000 8000 10000 Max. Output Current [A] 22.7 27.3 31.8 36.4 45.5 4000m (>3000m Power Derating) Noise [dBA] <35 Ingress Protection IP65 Weight [kg] 43.5 Non-isolated -40℃ to +60℃ (45℃ and above with derating) Cooling Method Dimensions [H*W*D] [mm] AC Output [Back-up] LED+APP Wi-Fi/Ethernet/4G(Optional) General Parameters Altitude 0.8 leading~0.8 lagging Rated AC Voltage/Range [V] 11 PV Connection Topology AC Input [On-grid] Max. Input Current [A]@230Vac 97.0% Integrated 7000 Total Harmonic Distortion [THDi] 97.6% Euro Efficiency AC Surge Protection 6000 Power Factor [cos φ] Max. Efficiency Integrated 5000 Rated Output Frequency/Range [Hz] <3% DC Surge Protection Rated AC Power [W] 63 50,60/45~55,55~65 Integrated 50/50 Rated AC Voltage/Range [V] 12000,60s L+N+PE, 220, 230, 240/180~280 AC Short Circuit Current Protection AC Output [On-grid] Max. AC Over Current Protection[A] H2-10K-S3 9600,60s Integrated Battery Parameters Battery Voltage Range [V] H2-8K-S3 8400,60s Over Load Protection 3 Battery Type Output THDv (@ Linear Load) H2-7K-S3 72000,60s Battery Input Reverse Polarity Protection 19.2/19.2/19.2 No. of MPPT Rated Output Frequency/Range [Hz] H2-6K-S3 6000,60s Protection 16/16/16 Max. DC Short Circuit Current [A] Rated AC Voltage/Range [V] H2-5K-S3 Efficiency 90~550 Rated DC Voltage [V] Peak Output Apparent Power [VA] Warranty [Year] Standard 430.5* 549 *223 26 Refer to the warranty policy CEI 0-21, VDE4105-AR-N, VDE0126-1-1, EN50438, G98, G99, EN50549, AS4777.2, IEC62109-1&-2, IEC62040-1 , EN61000-6-1/2/3/4 12 H2 Series 4.1 Unpacking and Inspection 4.1.1 Checking the Package 4. INSTRUCTIONS FOR INSTALLATION Although SAJ’s products have thoroughly tested and checked before delivery, there is possibility that the products may suffer damages during transportation. Please check the package for any obvious signs of damage, and if such evidence is present, do not open the package and contact your dealer as soon as possible. 4.1.2 Scope of Delivery Please contact after sales if there are missing or damaged components. Inverter Package Hexagon Philips bolt group M5*12 1PCS H2 Inverter*1 Sunk screw M4*10 Waterproof PV terminal 3*2 Documents AC terminal*6 Current transformer*1 120Ω resistor*1 Rear Panel*1 terminal block*1 12PCS Battery terminal 1*2 communication M6*50 screw suite*4 Communication module*1 Waterproof AC (Optional) terminal block*1 Smart meter*1 Meter COMM cable*1 (1000mm) The documents include the user manual and packaging list. 13 14 H2 Series 4.2 Installation Method and Position 4.2.2 Mounting Method 4.2.1 Installation Position and Clearance This device is cooled by natural convention and suggested an indoor installation or an installation under a sheltered place to prevent the product from exposure to direct sunlight, rain and snow erosion. Figure 4.1 Keep away from sunlight Keep dry Keep it clear of snow Sun Rain Accmulated snow Installation location Please reserve enough clearance around the product to ensure a good air circulation at the installation area. Because poor air ventilation will affect the working performance of internal electronic components and 50CM shorten the service life of the system. Figure 4.3 Mounting method ① The equipment employs natural convection cooling, and it can be installed indoor or outdoor. ② Mount vertically. Never install the device tilted forwards, sideways, horizontally or upside down. 30CM 50CM 50CM ③ When mounting the device, please consider the solidity of wall for product, including accessories, make sure the wall has enough strength to hold the screws and bear the weight of products. Please ensure the mounting bracket mounted tightly. Installation Environment Requirements 50CM • The installation environment must be free of inflammable or explosive materials. Figure 4.2 Installation clearance 15 • Install the device away from heat source. • Do not install the device at a place where the temperature changes extremely. • Keep the device away from children. 16 H2 Series • Do not install the device at daily working or living arears, including but not limited to the following areas: 4.3.2 Mounting Procedures bedroom, lounge, living room, study, toilet, bathroom, theater and attic. • When installing the device at the garage, please keep it away from drive way. 1. Mark the Positions of the Drill Holes on the Rear Panel • Keep the device from water sources such as taps, sewer pipes and sprinklers to prevent water seepage. The mounting position should be marked as shown in the following figure. • The product is to be installed in a high traffic area where the fault is likely to be seen. Note: When installing outdoors, the height of the device from the ground should be considered to prevent the device from soaking in water. The specific height is determined by the site environment. 360 165 4.3 Mounting Procedure 8 4.3.1 Installation Tools Installation tools include but are not limited to the following recommended ones. Please use other auxiliary tools on site if necessary. 16 Figure 4.4 Marker Measuring tape Utility knife Multimeter Measurement range: 1100Vdc Mark positions Insulated shoes 2. Drill Holes and Place the Expansion Tubes 17 Protective gloves Dust mask Earplugs Goggles Phillips screwdriver Wrench Heat shrink tubing Heat gun Hammer drill Drill bit: Φ10 Rubber mallet Drill 4 holes in the wall (in conformity with the position marked in Figure 4.4), and then place expansion tubes in the holes using a rubber mallet. 18 H2 Series 360 4. Mount the Inverter 4-∅8 Carefully mount the inverter into the rear panel as shown in Figure 4.7. Make sure that the rear part of the equipment is closely mounted into the rear panel. 165 Figure 4.5 Drill holes for installation 3. Secure the Screws and the Rear Panel Figure 4.7 Mount the inverter The panels should be secured onto the mounting position by screws as shown in Figure 4.6. Figure 4.6 Secure the panel 19 20 H2 Series 5.1 Additional Grounding Cable 5. ELECTRICAL CONNECTION 21 Electrical connection must only be operated by professional technicians. Before connection, necessary protective equipment must be employed by technicians, including insulating gloves, insulating shoes and safety helmet. WARNING · Connect this additional grounding cable before other electrical connection. Note: The additional cable and OT/DT terminal should be prepared by user themselves. 1 2 Figure 5.1 Preparing additional grounding cable 1. Heat shrink tubing 2. OT/DT terminal Remove the screw of grounding terminal and secure the additional grounding cable by insert a screw into the screw hole in the OT/DT terminal. Connect the grounding cables as the following diagram. Note: A 6 mm2 conductor cross-sectional area of cable is recommended for additional grounding cable. 22 H2 Series Figure 5.2 Connecting the additional grounding cable Figure 5.3 5.2 AC Grid Wire and Backup Output Connection Thread the cables Step 2: Fix the cables according to conductor marks of L, N and PE. Cable cross-sectional area(mm²) Range Recommend 13~21 16 Additional grounding cable cross-sectional area (mm²): 6 Table 5.1 Recommended specifications of AC cables Note: If the grid-connection distance is too far, please select an AC cable with larger diameter as per the actual condition. Procedure: Step 1: Open the waterproof cover, feed the AC cable through the AC waterproof hole. Figure 5.4 Connect the Cables 23 24 H2 Series Step 3: Secure all parts of the grid and backup connector tightly. 5.2.2 Earth Fault Alarm This inverter complies with IEC 62109-2 clause 13.9 for earth fault alarm monitoring. If an Earth Fault Alarm occurs, the ring light will be lit up in red and error code <31> will be displayed on LED panel 1 until the error being solved and inverter functioning properly. Note:The inverter cannot be used with functionally earthed PV Arrays. 5.2.3 External AC Circuit Breaker and Residual Current Device Please install a circuit breaker to ensure the inverter is able to disconnect from grid safely. The integrated leakage current detector of inverter is able to detect the real time external current leakage. When a leakage current detected exceeds the limitation, the inverter will be disconnected from grid quickly. The inverter does not require an external residual current device, as it has integrated with a RCMU. If local regulations require the application of external residual current device, either type A or type B RCD is compatible with the inverter. The action current of external residual current device should be 300mA. Figure 5.4 Screw the Connector Step 4: During off grid operation time, PE line at the BACK-UP end will remain to be connected with the PE line at the power grid end inside the inverter. (Only applicable to market in Australia) Inverter type Recommended breaker specification H2-5~10K-S3 100A Notice: Do not connect multiple inverters to one AC circuit breaker. Table 5.2 Recommended circuit breaker specification 5.2.1 Multiple Inverter Combinations Inverter 1 Phase Inverter 1 Phase A B C N Test Circuit Connection 3 Phase 5.3 PV Side Connection The inverter should not be installed in multiple phase combinations. If any such multiple inverter WARNING combination is not tested,it should not be used or · Make sure the PV array is well insulated to ground before connecting it to the inverter. external devices should be used in accordance with the requirements of AS/NZS 4777.1 Conductor cross-sectional area of cables(mm²) Inverter 1 Phase Scope Recommended value 4.0~6.0 4.0 Conductor material Outdoor multi-core copper wire cable, complying with 600Vdc Table5.3 Recommended specifications of DC cable 25 26 H2 Series 5.3.1 PV Connector Assembly 3. Assembly the positive and negative cables with corresponding crimping pliers. WARNING Dangerous to life due to electric shock when live components or DC cables are touched. · The PV panel string will produce lethal high voltage when exposed to sunlight. Touching live DC cables results in death or lethal injures. · DO NOT touch non-insulated parts or cables · Disconnect inverter from voltage sources. · DO NOT disconnect DC connectors under load. · Wear suitable personal protective equipment for all work. Figure 5.7 Inserting cables to lock screws DC connector is made up of positive connector and the negative connector 4. Insert the positive and negative cable into positive and negative connector. Gently pull the cables backward to ensure firm connection. Figure 5.5 Positive connector & Negative connector NOTICE · Please place the connector separately after unpacking in order to avoid confusion for connection of cables. · Please connect the positive connector to the positive side of the solar panels, and connect the negative connector to the negative side of the solar side. Be sure to connect them in right position. Connecting Procedures: 1. Loosen the lock screws on positive and negative connector. 2. Strip the insulation of the positive and negative cables with 8-10mm length. Figure 5.8 Inserting crimped cables to connectors 5.Fasten the lock screws on positive and negative connectors. positive cable Figure 5.9 Securing the connectors negative cable Figure 5.6 Striping off the insulation skin of cables 27 28 H2 Series 5.4 Communication Connection 6.Make sure the DC switch is at OFF position Notes: 1. Confirm that the DC switch is OFF during installation to avoid short circuit caused by wrong operation during battery wiring. 2. Please use the battery cable in original package. Attention: The meter can only be connected to the RS485-A1+ and RS485-B1- signal ports. EMS/METER Figure 5.10 DC switch 7.Connect the positive and negative connectors into positive and negative DC input terminals of the inverter, a “click” should be heard or felt when the contact cable assembly is seated correctly. + PV+ - PV+ - PV- + PV- CT DRM 1 RS485-A1+ 1 R/CT.I+ 1 DRM1/5 2 RS485-B1- 2 R/CT.1- 2 DRM2/6 3 NC 3 NC 3 DRM3/7 4 NC 4 NC 4 DRM4/8 5 NC 5 NC 5 RefGen 6 NC 6 NC 6 Com/DRM0 7 RS485-A2+ 7 NC 7 V+ 8 RS485-B2- 8 NC 8 V- CAN/BMS PORT0 PORT1 1 NC 1 NC 1 NC 2 NC 2 NC 2 NC 3 NC 3 NC 3 NC Figure 5.11 4 CANH 4 NC 4 NC Plug in PV connectors 5 CANL 5 NC 5 NC 6 NC 6 NC 6 NC 7 NC 7 NC 7 NC 8 NC 8 NC 8 NC 29 30 H2 Series Thread the communication cable through the waterproof cable gland and connect to the corresponding port. Plug in the communication module to 4G/WIFI port and secure the module by rotating the nut. 1. 4G/Wi-Fi port could be externally connected with eSolar 4G module, eSolar Wi-Fi module or eSolar AIO3 module, for operation in details please refer to communication module Quick Installation Guide in https://www.saj-electric.com/ . 5.6 Connecting Battery Power Cable · · Power off the battery system before connecting the power cable to avoid high voltage danger The electrical connection of high voltage battery systems must be operated by qualified technicians in accordance with local and national power grid standards and regulations. Figure 5.12 Communication cable connection 5.7 Battery Connection 5.5 Communication Module Installation If lithium battery is connected, it is not required to install a breaker between battery and inverter. Cable Cross-sectional area(mm²) Range Recommend 8~10 8 Table 4.4 Recommended specifications of DC cables Figure 5.13 4G/WiFI port 31 32 H2 Series Procedure: 1. Open the waterproof cover, then feed the battery cable through the AC waterproof hole. Figure 5.14 3.Fix the battery cable on the battery copper terminal by positive and negative in order. Figure 5.15 Open the waterproof cover Connecting battery power cables 4. Follow the clause 5.4 communication connection to check or install the BMS connection between inverter and battery in proper port. 2.Strip off the insulation skin of DC cable, the core is exposed to 15mm, • Open the spring using a 3mm wide bladed screwdriver . • Carefully insert the stripped wire all the way in • The wire ends have to be visible in the spring. • Close the spring. Make sure that the spring is snapped in • Push the insert into the sleeve • Tighten the cable gland Inverter BMS/CAN BAT+ BAT- BATCOMM BAT+ Figure 5.16 communication connection Figure 5.15 Battery Terminal 33 34 H2 Series 5.8 System Connection 35 The system connection for grid system without special requirements is as below. The system connection in Germany, Australia and New Zealand is as below, the neutral cable of AC and Note:The backup PE line and earthing bar must be grounded properly. Otherwise, backup function may be backup side must be connected together for the safety reason. Note: DO NOT connect the PE terminal of BACKUP side. inactive during blackout. 36 H2 Series 5.9 System Connection Diagram Note: If the RS485 cable length between inverter and meter is longer than 20m, please install the 120Ω resistor in port 24&25 of the meter. 5.10 AFCI (Optional) The inverter is equipped with arc-fault circuit interrupter (AFCI). With AFCI protection, when there is an arc signal on the DC side due to aging of the cable or loose contact, inverter can quickly detect and cut off the power to prevent fire, making the PV system run more safely. 37 38 H2 Series 6. 6.1 Start Up and Shut Down the Energy Storage System 6.1.1 Start Up Step 1: Turn on the circuit breaker Step 2: Press and hold the main switch for 2-3s,until the display is on 6.1.2 Shut Down Automatically shut down, when the solar light intensity is not strong enough during sunrise and sunset or the output voltage of photovoltaic system is less than the minimum input power of inverter, inverter will shut down automatically. Shut down manually, disconnect AC side circuit breaker first, if multiple inverters are connected, disconnect the minor circuit breaker prior to disconnection of main circuit breaker. Disconnect the DC switch after inverter has reported grid connection lost alarm. 6.2 Introduction of Human-Computer Interface System commissioning COMMISSIONING After the wiring is completed, please refer to the inverter manual for system commission and operation. Note: Turn on the circuit breaker and main switch when using battery. Figure 6.3 Human-computer interface 39 40 H2 Series LED indicator Description Status LED off Breathing Solid LED indicator Status Description Communication On 1s, off 3s Meter communication is lost, BMS communication is good Off Both meter and BMS communication are lost Solid Connected On 1s, off 1s Connecting Off Disconnected Inverter power off Inverter is at initial state or standby state Inverter running properly Cloud Table 6.1 Interface description Breathing System Battery Grid Solid Inverter is faulty Solid Importing electricity from grid On 1s, off 1s Exporting electricity to grid On 1s, off 3s Not importing and exporting at all Backup 6.3 Commissioning (1) Connect the AC circuit breaker (2) Connect the DC circuit breaker between inverter and battery (if applicable) (3) Turn ON the battery (if applicable) Off-grid Solid Battery is discharging On 1s, off 1s Battery is charging (5) Install the communication module into the inverter On 1s, off 3s SOC low (6) Setup the initial setting for inverter on eSAJ Home Off Battery is disconnected or inactive Solid Connected to grid (4) Turn ON the DC switch on the inverter (7) Observe the LED indicators on the inverter to ensure the inverter is running properly On 1s, off 1s Counting down to grid connection 6.4 eSAJ APP Connection On 1s, off 3s Grid is faulty 6.4.1 Account Login Off No grid Step 1: Log in to eSAJ Home, if you do not have an account, please register first. Solid PV array is running properly Step 2: Go to the “Tool” interface and select “Remote Configuration” PV array is faulty Step 3: Click on “Bluetooth” and activate the Bluetooth function on your phone, then click on “Next” Off PV array is not operating Solid AC side load is running properly On 1s, off 1s AC side load overload Off AC side is turned off Solid Both BMS and meter communication are good On 1s, off 1s 41 Note: One breathing cycle is 6 seconds. Off On 1s, off 1s PV Inverter is upgrading Step 4: Choose your inverter according to your inverter SN’s tail numbers Step 5: Click on the inverter to enter inverter setting Step 6: Select the corresponding country and grid code for Meter communication is good, BMS communication is lost 42 H2 Series 6.4.2 Local Connection Step 1: Open eSAJ APP and click on the dot icon on the top right corner Step 2: Select “Local Connection” Step 3: Enter password “123456” Step 4: Click on “Bluetooth” and activate the Bluetooth function on your phone, then click on “Next” Step 5: Choose your inverter according to your inverter SN’s tail numbers Step 6: Click on the inverter to enter inverter setting Step 7: Select the corresponding country and grid code for 43 44 H2 Series 6.4.3 Inverter Setting Review After commissioning, the device info including device basic info, running info and event info can be viewed. Country and grid code can be viewed from initial setting. 45 46 H2 Series 6.5 Working Modes 6.6 Export Limit Setting 6.5.1 Selecting Working Modes Procedures 6.5.2 Working Modes Introduction Self-consumption Mode: When the solar is sufficient, electricity generated by photovoltaic system will be supplied to load first, the surplus energy will be stored in battery, then the excess electricity will be exported to the grid. When the solar is Note: If the RS485 cable length between inverter and meter is longer than 20m, please install the 120Ω resistor in port 24&25 of the meter. insufficient, the battery will release electricity to supply load. Back-up Mode: Reserved Backup SOC setting value can be adjusted, when battery SOC is less than reserved SOC value, battery can only be charged, until SOC reaches reserved value, the battery will be stopped charging; when SOC is larger than SOC setting value, battery will behave as Self-use mode. Time-of-use Mode: Battery charging period and discharging period can be set , during charging period, battery can only be charged, while in discharging period, battery can only be discharged, the rest of the period, battery will behave as Self-use mode. 47 48 H2 Series 6.7 Self-test (For Italy) 6.6.1 APP Setting Italian Standard CEI0-21 requires a self-test function for all inverter that connected to utility grid. During the self-testing time, inverter will check the reaction time for over frequency, under frequency, overvoltage and undervoltage. This self-test is to ensure the inverter is able to disconnect from grid when required. If the self-test fails, the inverter will not able to feed into the grid. The steps of running Self-test are as followed: Step 1: Connect a communication module (Wi-Fi/ 4G/Ethernet) with inverter (connection procedure can refer to eSolar Module Quick Installation Manual) Step 2: Select Italy for Country and choose your corresponding Grid Code from Initial Setting. There are two methods to control the export limit, the two methods are alternative to each other. Method 1: Export limitation setting is to control the export electricity to the grid. Method 2: Generation limit is to control the electricity generated by the inverter. Step 3: You can choose self-test item required. Individual self-test time is approx. 5 minutes. All self-test time is approx. 40 minutes. After the self-test is completed, you can save the test report. If self-test is failed, please contact with SAJ or your inverter supplier. 49 50 H2 Series 6.8 Setting Reactive Power Control (For Australia) 6.8.1 Setup Fixed Power Factor Mode & Fixed Reactive Power Mode Fixed Power Factor Mode Step 1: Select Power Adjustment and enter password “201561”. Step 2: Select Capacitive Power Factor or Inductive Power Factor according to your local grid regulation. The power factor range is from 0.8 leading ~ 0.8 lagging. 51 52 H2 Series Fixed Reactive Power Mode Figure 6.2 Curve for a Volt-Watt response mode (AS4777 Series) Figure 6.3 Curve for a Volt-Var control mode (AS4777 Series) Step 1: Select Inductive Adjustment Var or Capacitive Var according to your local grid regulation. The power range is from -60%Pn ~ 60%Pn. Setting procedure: 1. AS4777 grid compliance has been set during production, please select corresponding grid compliance according to state regulation during installation. You can choose a state regulation compliance with your local grid via eSAJ Home. 6.8.2 Setup V-Watt and Volt-Var Mode This inverter complies with AS/NZS 4777.2: 2020 for power quality response modes. The inverter satisfies different regions 2. Log in to eSAJ Home, click “Local Connection”, for connection procedure please refer to chapter 5.3 for Nearby monitoring. 3. Click “V-Watt/V-Var” to enter DNSPs settings, choose a suitable state regulation from the drop down list. of DNSPs' grid connection rules requirements for volt-watt and volt-var Settings. e.g.: AS4777 series setting as below Fig 6.2&6.3. 53 54 H2 Series Note: With regard to the Power rate limit mode, SAJ sets the product WGra to 16.67%Pn by default in the following cases according to the requirements of 3.3.5.2 as 4777.2: 2020. 1. Soft ramp up after connect. 2. Reconnect or soft ramp up/down following a response to frequency disturbance. 55 56 H2 Series 7.1 Transportation 7. TRANSPORTATION &DISPOSAL 57 Take care of the product during transportation and storage, keep less than 4 cartons of inverter in one stack. 7.2 Recycling and Disposal This device should not be disposed as residential waste. An inverter that has reached the end of its life and is not required to be returned to your dealer, it must be disposed carefully by an approved collection and recycling facility in your area. 58 H2 Series Inverter Cleaning 8. Clean the enclosure lid and LED indicator of the inverter with moistened cloth with clear water only. Do not use any cleaning agents as it may damage the components. Heat Sink Cleaning Clean the heat sinks with dry cloth or air blower. Do not clean the heat sink with water or cleaning agents. Make sure there is enough space for ventilation of inverter. ROUTINE MAINTENANCE 59 60 H2 Series Troubleshooting 9. TROUBLESHOOTING & WARRANTY 61 Code Fault Information Code Fault Information 37 Master Islanding Error 38 Master HW Bus Voltage High 39 Master HW PV Current High 40 Master Self-Test Failed 41 Master HW Inv Current High 42 Master AC SPD Error 43 Master DC SPD Error 44 Master Grid NE Voltage Error 45 Master Fan1 Error 46 Master Fan2 Error 47 Master Fan3 Error 48 Master Fan4 Error 1 Master Relay Error 2 Master EEPROM Error 3 Master Temperature High Error 4 Master Temperature Low Error 5 Lost Communication M<->S 6 GFCI Device Error 7 DCI Device Error 8 Current Sensor Error 9 Master Phase1 Voltage High 10 Master Phase1 Voltage Low 11 Master Phase2 Voltage High 12 Master Phase2 Voltage Low 13 Master Phase3 Voltage High 49 Lost Communication between Master and Meter 14 Master Phase3 Voltage Low 50 Lost Communication between M<->S 15 Grid Voltage 10Min High 16 OffGrid Output Voltage Low 51 Lost Communication between inverter and Grid Meter 17 OffGrid Output Short Circuit 52 HMI EEPROM Error 18 Master Grid Frequency High 53 HMI RTC Error 19 Master Grid Frequency Low 54 BMS Device Error 21 Phase1 DCV High 55 BMS Lost.Conn 22 Phase2 DCV High 56 CT Device Err 23 Phase3 DCV High 57 AFCI Lost Err 24 Master No Grid Error 58 Lost Com. H<->S Err 27 GFCI Error 28 Phase1 DCI Error 59 Lost Communication between inverter and PV Meter 29 Phase2 DCI Error 61 Slave Phase1 Voltage High 30 Phase3 DCI Error 62 Slave Phase1 Voltage Low 31 ISO Error 63 Slave Phase2 Voltage High 32 Bus Voltage Balance Error 64 Slave Phase2 Voltage Low 33 Master Bus Voltage High 65 Slave Phase3 Voltage High 34 Master Bus Voltage Low 66 Slave Phase3 Voltage Low 35 Master Grid Phase Lost 67 Slave Frequency High 36 Master PV Voltage High 68 Slave Frequency Low 62 H2 Series Code Fault Information 73 Slave No Grid Error 74 Slave PV Input Mode Error 75 Slave HW PV Curr High 76 Slave PV Voltage High 77 Slave HW Bus Volt High 81 Lost Communication D<->C 83 Master Arc Device Error 84 Master PV Mode Error 85 Authority expires 86 DRM0 Error 87 Master Arc Error 88 Master SW PV Current High 89 Battery Voltage High 90 Battery Current High 91 Battery Charge Voltage High 92 Battery OverLoad 93 Battery SoftConnet TimeOut 94 Output OverLoad 95 Battery Open Circuit Error 96 Battery Discharge Voltage Low Warranty Please go to SAJ website for warranty conditions and terms https://www.saj-electric.com/ Please contact your supplier for troubleshooting and remedy. 63 64 ">
/
Scarica
Solo un promemoria. Puoi visualizzare il documento qui. Ma soprattutto, la nostra IA l''ha già letto. Può spiegare cose complesse in termini semplici, rispondere alle tue domande in qualsiasi lingua e aiutarti a navigare rapidamente anche nei documenti più lunghi o complicati.
Pubblicità