Extron MPA 601 Setup Guide
PDF
Документ
Реклама
Реклама
V C G CLASS 2 WIRING REMOTE NT: plete RTAfor the coomns, and O P m o M I tron.c instructi ng the .ex on ecti . www stallati e conn Go to uide, in s before er sourc g w n r o o e p ti s e u ica th if c to e sp uct prod MPA 601-70V and MPA 601-100V • Setup Guide This guide provides basic instructions for an experienced installer to install and configure the Extron MPA 601-70V and MPA 601-100V mini power amplifiers. See below for front and rear panels of the MPA 601-70V. INPUTS L LEVEL BASS TREBLE POWER 12V 1.3A MAX (SUMMED) G TIMER OFF L (SUMMED)R STANDBY 10V 50mA MPA 601-70V 70V OUTPUT R R MPA 601 V C G REMOTE MINI POWER AMPLIFIER CLASS 2 WIRING Step 1 — Turn all of the equipment off and disconnect all power sources. Step 2 — Mount the amplifier in either a plenum space, on a rack, under a desk, or on a projector. ATTENTION: • Although the amplifier is plenum rated, the power supply provided with it is not. The power supply must not be placed in the plenum space. Cables to and from the amplifier must be plenum rated. • Bien que l’amplificateur soit conforme à la norme relative aux faux plafonds, la source d’alimentation fournie avec ne l’est pas. La source d’alimentation ne doit pas être placée dans l’espace plenum. Les câbles depuis et vers l’amplificateur doivent aussi être classés plenum. • Use only the two round mounting holes for mounting the MPA 601. The other four (hexagonal) holes anchor stand-offs for the internal circuit boards. Using them may damage the amplifier and does not provide secure mounting for the unit. • Utilisez seulement les deux trous pour monter le MPA 601. Les autres quatre trous d’ancrage sont destinés aux cartes de circuit internes. Le fait de les utiliser pourrait endommager l’amplificateur et n’assurera pas un montage sécurisé pour l’unité. Step 3 — Attach the speakers to the MPA 601 using the 2-pole, 5 mm screw‑lock captive screw speaker receptacle on the rear panel. 70V OUTPUT ATTENTION: • Do not ground or short the speaker outputs as this will damage the amplifier. • Ne pas mettre à la terre ni créer de court-circuit dans les sorties de l’enceinte, afin d’éviter tout risque de détérioration de l’amplificateur. Step 4 — Attach sources to the MPA 601 unit from the audio source or projector. The three rear panel audio inputs can be used individually or together: • One pair of RCA receptacles (unbalanced) • One 3.5 mm stereo tip-ring-sleeve (TRS) receptacle (unbalanced) • One 3.5 mm, 5-pole captive screw receptacle (balanced or unbalanced) 3.5 mm TRS Connector RCA Connector L L Tip Sleeve Tip Ring Sleeve R R Balanced Stereo Input Sleeve ( ) Sleeve ( ) R R Unbalanced Stereo Input Tip Ring Sleeves Tip Ring Tip (L) Ring (R) Tip (+) L L Tip Sleeve Tip Sleeve Unbalanced Mono Input Balanced Mono Input NOTES: • • CLASS 2 WIRING The MPA 601 amplifier sums the left and right signals from both the TRS and RCA inputs to form Sum 1. Sum 1 is then weighted. At the same time, the amplifier sums the left and right signals from the captive screw input to form Sum 2. Sum 1 and Sum 2 are POWER 12V then summed together to form a single mono signal. Refer to the MPA 601 Series User 1.3A MAX Guide for more details regarding audio summing. INPUTS G L (SUMMED) L (SUMMED)R STANDBY 10V 50mA V C G REMOTE Ensure the audio output of the projector is set to variable. Multiple input options can be used simultaneously and be summed. 1 TIMER OFF G 70V O R R The captive screw, RCA and TRS inputs are buffered. INPUTS MPA 6 MPA 601-70V CLASS Step 5 — Connect power cords to the MPA 601 and other audio equipment. The MPA 601 ships with an Extron 50 W (12Vdc, 4.2A) desktop power supply. Connect the pre-wired captive screw connector into one of the two-pole, 3.5 mm captive screw outlets on the power supply and the other end into the power receptacle on the amplifier (see the figure to the right). The power cord connectors are correctly wired when shipped (see Attention below). MPA 601 series Amplifier 50W (12Vdc, 4.2A) Power Supply AC Power Cord Power Receptacle DC Power Outputs 12V 1.5A MAX ATTENTION: • See the attention notices in the Power Input section of the MPA 601 Series User Guide for important information about using power supplies. • Reportez-vous aux précautions d’emploi incluses dans la section sur l’entrée d’alimentation du MPA 601 Series User Guide pour des informations essentielles sur l’utilisation des sources d’alimentation. • When the 50 W (12Vdc, 4.2A) power supply is connected to the MPA 601, it must not be shared with any other devices. • Lorsque la source d’alimentation 50 W (12Vdc, 4.2A) est connectée au MPA 601, elle ne peut être partagée avec aucun autre appareil. DC Power Cord Captive Screw Connector Captive Screw Connector Tie Wrap Power Supply Output Cord LEVEL BASS TREBLE Step 6 — Adjust the MPA 601 input LEVEL, BASS, and TREBLE from the front panel (see figure at right). MPA 601 MINI POWER AMPLIFIER 1. If necessary, unplug the remote connector from the unit (see step 7, below). 2. If connecting the amplifier to a system with adjustable volume, set the volume to its lowest point. Then adjust the MPA 601 front panel LEVEL potentiometer fully counterclockwise. MPA 601-70V MPA 601-70V G INPUTS 3. 4. Set the system volume to its maximum volume level (no sound should come out). L POWER 12V ..A MAX L (SUMMED) G TIMER OFF TIMER OFF INPUTS L (SUMMED) R STANDBY 10V 50mA R 70V OUTPUT STANDBY 10V 50mA Return to the MPA 601 and raise the LEVEL until sound distortion first occurs, then(SUMMED) lower slightly untilLthe POWER (SUMMED)R R 12V distortion disappears. This setting ensures that, whatever the system volume setting may be, no clipping 1.3A MAX V C G REMOTE occurs. 100V OUTPUT R CLASS 2 WIRING R 5. Adjust BASS and TREBLE to preference. V C G REMOTE CLASS 2 WIRING Step 7 — The rear panel lower 3-pole Remote captive screw receptacle on the amplifier can be used for remote control of 601-100V the MPA G volume by an Extron volume controller such as an Extron VCM 110 AAP, VC 50, MLA VC10 Plus, or select MLC controllers. These L controllers have a built-in VC module that can be used to control the amplifier. MediaLink controllers can also adjust the 100V audio OUTPUT INPUTS (SUMMED) POWER L (SUMMED) R R 12V or by IR remote (see the MPA volume at the source, rather than with the volume control port, via a network connection 601 Series ..A MAX User Guide). R TIMER OFF STANDBY 10V 50mA Step 8 — The rear panel upper 3-pole Remote captive screw receptacle on the amplifier affects standby. When the STANDBY REMOTE pin is shorted to ground, the MPA 601 goes into standby mode. The front panel power LED turns amber to indicate when the MPA 601 is in standby. When the TIMER OFF pin is shorted to ground, the standby timer will be disabled, and the amplifier does not go into standby after 25 min (±5 min) of inactivity. The MPA 601 can still be forced into standby mode using the STANDBY pin, even if the timer has been defeated. V C G CLASS 2 WIRING When the short is removed from the STANDBY pin, the unit may remain in standby mode, depending on certain conditions: • The input signal is below the input signal detection threshold. • The standby timer is enabled. • The timeout interval since the last detection of a signal has elapsed. NOTE: If the TIMER OFF pin is shorted to ground, the unit will always come out of standby when the short is removed from the STANDBY pin. © 2016-2018 Extron Electronics All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com 68-2512-50 Rev. B 01 19 2 ">
/
Изтегляне
Само приятелско напомняне. Можете да видите документа точно тук. Но най-важното е, че нашият AI вече го е прочел. Той може да обясни сложни неща на прости термини, да отговори на вашите въпроси на всеки език и да ви помогне бързо да навигирате дори в най-дългите или най-сложните документи.
Реклама