Black Box LE1601A manual
Black Box LE1601A AUI to BNC Transceiver enables you to connect an Ethernet device to thin Ethernet coaxial cable over distances up to 606.8 feet (185 meters) without a repeater. It supports a data rate of 10 Mbps and complies with IEEE 802.3 transceiver specifications.
விளம்பரம்
விளம்பரம்
© Copyright 2003. Black Box Corporation. All rights reserved.
1000 Park Drive • Lawrence, PA 15055-1018 • 724-746-5500 • Fax 724-746-0746
MAY 2003
LE1601A
AUI to BNC Transceiver
CUSTOMER SUPPORT INFORMATION
Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)
FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746
Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018
Web site: www.blackbox.com • E-mail: [email protected]
FCC AND IC STATEMENTS
FEDERAL COMMUNICATIONS COMMISSION
AND
INDUSTRY CANADA
RADIO FREQUENCY INTERFERENCE STATEMENTS
This equipment generates, uses, and can radiate radiofrequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in
Subpart B of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment.
Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference
Regulation of Industry Canada.
1
AUI TO BNC TRANSCEIVER
FEDERAL COMMUNICATIONS COMMISSION
AND
INDUSTRY CANADA
RADIO FREQUENCY INTERFERENCE STATEMENTS
(continued)
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de classe
A prescrites dans le Règlement sur le brouillage radioélectrique publié par Industrie Canada.
2
TRADEMARKS USED IN THIS MANUAL
TRADEMARKS USED IN THIS MANUAL
Any trademarks mentioned in this manual are acknowledged to be the property of the trademark owners.
3
AUI TO BNC TRANSCEIVER
Contents
Chapter Page
1. Specifications . . . . . . . . . . . . . . . . . . 5
2. Introduction . . . . . . . . . . . . . . . . . . . 7
2.1 Description. . . . . . . . . . . . . . . . . 7
2.2 What the Package Includes. . . . 7
2.3 Features . . . . . . . . . . . . . . . . . . . 8
3. Installation. . . . . . . . . . . . . . . . . . . . 10
3.1 Disabling SQE Test . . . . . . . . . 10
3.2 Installing the Transceiver . . . . 11
4. Troubleshooting . . . . . . . . . . . . . . . 13
4.1 Calling Black Box . . . . . . . . . . 13
4.2 Shipping and Packaging . . . . . 14
Appendix. AUI (DB15) Connector
Pinout. . . . . . . . . . . . . . . . . . . . 15
4
CHAPTER 1: Specifications
1. Specifications
Standards:
IEEE 802.3
User Controls:
SQE switch
Maximum Coaxial Cable Segment
Distance:
Up to 606.8 ft. (185 m)
Speed:
10 Mbps
Connectors:
(1) DB15 AUI M, (1) BNC F
Indicators:
LEDs: (1) Power, (1) SQE
Temperature Tolerance:
Operating: 32 to 122°F (0 to 50°C);
Storage: -40 to +212°F (-40 to +100°C)
Relative Humidity:
Operating: 8 to 80%, noncondensing;
Storage: 5 to 98%, noncondensing
5
AUI TO BNC TRANSCEIVER
Power:
From the AUI interface
Size:
0.8"H x 1.6"W x 3.8"D
(2 x 4.1 x 9.7 cm)
Weight:
0.2 lb. (<0.1 kg)
6
CHAPTER 2: Introduction
2. Introduction
2.1 Description
The AUI to BNC Transceiver lets you connect an Ethernet device (such as a LAN card installed in a PC, or a bridge, router, hub, or repeater) to thin Ethernet coaxial cable. It connects either directly to the AUI port on the Ethernet device or via a standard AUI cable. The transceiver complies with IEEE 802.3 transceiver specifications.
2.2 What the Package Includes
Your package should include the following items:
• (1) AUI to BNC Transceiver
7
AUI TO BNC TRANSCEIVER
• (1) BNC T-connector
• This users’ manual
If anything is missing or damaged, please contact Black Box at 724-746-5500.
2.3 Features
• Provides a complete AUI to thin
Ethernet (10BASE2) interface, including transmit, receive, collision, and jabber functions, and SQE
(signal quality error) test.
• Supports message traffic at a data rate of 10 Mbps.
• Extends a coaxial cable segment up to 606.8 feet (185 m) without a repeater.
8
CHAPTER 2: Introduction
• Supports system configurations using the CSMA/CD access mechanism defined in the IEEE Local Area
Network specifications.
9
AUI TO BNC TRANSCEIVER
3. Installation
3.1 Disabling SQE Test
When the transceiver is attached to a LAN card, bridge, or router, the SQE switch
(located on the bottom of the transceiver) should be ON.
When the transceiver is attached to a hub or repeater, the SQE switch should be
OFF.
NOTE
The transceiver is shipped from the factory with the SQE (heartbeat) test enabled (ON).
10
CHAPTER 3: Installation
3.2 Installing the Transceiver
1. Turn the power to the network device off.
2. Connect a BNC T-connector to the transceiver’s BNC female connector, then connect thin coax cable to the
T-connector. If only one end of the
T-connector is connected, install a
50-ohm BNC terminator on the other end.
3. Use a standard AUI cable (50 ft.
[15.2 m] long) to connect an
Ethernet device to the transceiver’s
DB15 AUI connector, or directly mount the transceiver to a DTE.
4. Turn the power to the network device back on. Verify that the Power
LED on the transceiver is on.
11
AUI TO BNC TRANSCEIVER
Once the transceiver is installed, it operates automatically in half-duplex mode. When the SQE LED lights, a collision is detected on the AUI port.
12
CHAPTER 4: Troubleshooting
4. Troubleshooting
4.1 Calling Black Box
If you determine that your AUI to BNC
Transceiver is malfunctioning, do not attempt to alter or repair the unit. It contains no user-serviceable parts. Contact
Black Box at 724-746-5500.
Before you do, make a record of the history of the problem. We will be able to provide more efficient and accurate assistance if you have a complete description, including:
• the nature and duration of the problem.
• when the problem occurs.
13
AUI TO BNC TRANSCEIVER
• the components involved in the problem.
• any particular application that, when used, appears to create the problem or make it worse.
4.2 Shipping and Packaging
If you need to transport or ship your AUI to BNC Transceiver:
• Package it carefully. We recommend that you use the original container.
• If you are shipping the transceiver for repair, make sure you include everything that came in the original package. Before you ship, contact
Black Box to get a Return
Authorization (RA) number.
14
APPENDIX: AUI (DB15) Connector Pinout
Appendix. AUI (DB15)
Connector Pinout
Pin
1
2
Symbol
CI-S
CI-A
Name/Function
Control-In Shield: The shield for the
CI twisted pair in the AUI cable.
Control-In Circuit A: The positive signal for the CI circuit. With CI-B,
CI-A is an output current driver pair to the CI circuit. This output pair is activated when a collision is detected on the network, either during self-test
(heartbeat) as the SQE test sequence or after the watchdog timer has expired to indicate that the transmitter is disabled.
15
4
5
6
7
8
AUI TO BNC TRANSCEIVER
Pin
3
Symbol
DO-A
DI-S
DI-A
VC
NC
NC
Name/Function
Data-Out Circuit A: The positive signal for the DO circuit. With DO-B,
DO-A is a differential receiver input pair from the DO circuit. This input pair receives 10-Mbps Manchesterencoded data from the AUI transceiver cable, which is driven by the DTE (terminal or computer).
Data-In Shield: The shield for the DI twisted pair in the AUI cable.
Data-In Circuit A: The positive signal for the DI circuit. With DI-B, DI-A is an output current driver pair to the DI circuit. This output pair drives the
AUI transceiver cable with 10-Mbps
Manchester-encoded data received from the coaxial cable wire of the network.
Voltage Common
Not Connected
Not Connected
16
Pin
APPENDIX: AUI (DB15) Connector Pinout
Symbol Name/Function
9
10
11
CI-B
DO-B
DO-S
Control-In Circuit B: The negative signal for the CI circuit. With CI-A,
CI-B is an output current driver pair to the CI circuit. This output pair is activated when a collision is detected on the network, either during self-test
(heartbeat) as the SQE test sequence or after the watchdog timer has expired to indicate that the transmitter is disabled.
Data-Out Circuit B: The negative signal for the DO circuit. With DO-A,
DO-B is a differential receiver input pair from the DO circuit. This input pair receives 10-Mbps Manchesterencoded data that is driven by the
DTE (terminal or computer).
Data-Out Shield: The shield for the
DO twisted pair in the AUI cable.
17
AUI TO BNC TRANSCEIVER
Pin
12
Symbol
DI-B
13 VP
14
15
Shell
VS
NC
PG
Name/Function
Data-In Circuit B: The negative signal for the DI circuit. With DI-A, DI-B is an output current driver pair to the DI circuit. This output pair drives the
AUI transceiver cable with 10-Mbps
Manchester-encoded data received from the coaxial cable wire of the network.
Voltage Plus: The power supply to the transceiver.
Voltage Shield
Not Connected
Protective Ground: Chassis ground from the DTE. This circuit is connected to the outer shell of the transceiver.
18