TM40 Touch Interface
Module
Quick Install Guide
TM40-EI01
2.
Mount the back plate to the wall by securing a M3.5 or #6 screw in each of the dedicated mounting holes and tamper hole. Ensure that the UP arrow on the back plate is in the up position.
Installation
1.
Using a screwdriver, pry the front housing assembly from the back plate.
3.
Assemble both items by joining the hooks on the back plate to their respective slots on the front housing assembly.
Hooks on back plate
Front housing assembly
Printed in Canada | 09/2011
NOTE: Make sure to connect the unit’s 5-pin connector before proceeding to the next step.
TM40 Quick Install Guide
4.
Secure the front housing assembly to the back plate by snapping it into place.
The installation process is complete.
TM40 to Panel Connections
As shown in the Wiring Diagram, the red, black, green, and yellow
wires on the TM40 must be connected to their corresponding labeled terminals on the control panel’s PCB. The blue wire is connected to either a keypad zone or external temperature sensor.
TM40 Quick Install Guide
Wiring Diagram
Kpd 1 or Kpd 2
N.C
.
BLUE
COM
ZONE/TEMP
RED
BLK
GRN
YEL
CONTROL PANEL
AUX+ AUX- GRN YEL
Technical Specifications
Power Input 9 to 16 Vdc
Consumption 110 mA
Display 16-bit, color LCD; 5.4 x 9.5 cm (2.1 x 3.7 in.)
Resolution 480 x 272 pixels
Dimensions 12.4 x 8.1 x 1.6 cm (4.9 x 3.2 x 0.7 in.)
Weight 0.15 kg (0.33 lbs.)
Humidity 5-90%
Sensors Indoor temperature sensor
Standards Complies with EN 50131 Security Grade 3 Class II
Warranty : For complete warranty information on this product, please refer to the Limited Warranty Statement found on the Web site www.paradox.com/terms. Your use of the Paradox product signifies your acceptance of all warranty terms and conditions.
© 2011 Paradox Ltd. All rights reserved. Specifications may change without prior notice. www.paradox.com