Simrad IS70 / IS80 Reference Guide
Simrad SP70 - REV D offers crucial nautical information at a glance with its high-contrast display. It's ideal for powerboats and sailboats and provides accurate speed readings in knots. With adjustable backlighting, the display is easily readable in various lighting conditions, and its compact size ensures seamless integration into any helm.
Advertisement
Advertisement
Manual
Simrad IS70/IS80
RPM Indicators RPM70 and RPM80
Speed Indicators SP70 and SP80
English
www.simrad-yachting.com
A brand by Navico - Leader in Marine Electronics
Manual
Simrad IS70/IS80
RPM indicators RPM70 and RPM80
Speed indicators SP70 and SP80
English
Document no: 20243861
Revision:
Date:
A
April 2009
The original language for this document is English. In the event of any discrepancy between translated versions and the English version of this document, the English document will be the official version.
To the best of our knowledge, the content in this publication was correct at the time of printing.
As we are continuously improving our products we retain the right to make changes to the product and the documentation at any time. Updated manuals are available from our website www.simrad-yachting.com, and are free to download.
© Copyright 2009 by Navico Holding AS.
About this manual
This manual is a reference guide for installing and operating the Simrad RPM70/RPM80 indicators and SP70/
SP80 speed indicators.
The manual does not include installation procedures for sensors that can be connected to the system.
In this manual, names of modes and keys are written in boldface (e.g. User setup, Mode/Setup key).
In the illustrations throughout the manual the following symbols are used:
3 s Time indication (1, 3, 5 or 10 seconds)
3 s
SELECT
3 s
MODE
SETUP
+
SELECT
SELECT
Single key press with time indication
Combined key press with time indication
Repeated key presses on single key
Important text that requires special attention from the reader is emphasized as follows:
Used to draw the reader’s attention to a comment or some important information.
When necessary, used to warn personnel they should proceed carefully to prevent risk of injury and/or damage to equipment.
2 | RPM70/RPM80 and SP70/SP80 indicators
Contents
1 Introduction ............................................... 5
General information ......................................5
Instrument layout .........................................5
2 Installation ................................................. 7
Location of the unit .......................................7
Panel mounting .............................................7
Cable connection and interface .......................8
Securing the cables .......................................9
Interconnecting instruments ...........................9
Installation setup ........................................ 10
3 Operation ................................................. 11
Turning indicators on ................................... 11
Using the keys ............................................ 11
Backlighting ............................................... 12
Error Alarm ................................................ 12
Maintenance ............................................... 13
Operation flow chart .................................... 14
4 Changing the default settings ................... 15
General ..................................................... 15
Light bank selection .................................... 15
5 Spare parts ............................................... 17
Spares and auxiliaries .................................. 17
SimNet cables and accessories ..................... 17
RPM70/RPM80 and SP70/SP80 indicators | 3
6 Specifications ........................................... 19
Technical specifications ................................ 19
Dimensional drawing ................................... 20
4 | RPM70/RPM80 and SP70/SP80 indicators
1 Introduction
General information
The RPM70 and RPM80 instruments present you with the engine r/min.
The SP70 and SP80 instruments present you with the vessel speed in knots.
Adjustable backlight for night operation is provided as well as adjustable intensity for operation in sunshine.
Instrument layout
The RPM70 and RPM80 displays include a pointer and a circular scale with rpm indication.
The following scales are available:
•
•
0 - 3000 rpm
0 - 6000 rpm
The SP70 and SP80 displays include a pointer and a circular scale with speed indication.
The following scales are available:
•
•
0 - 25 knots
0 - 50 knots
The instrument is operated by 2 keys. These are used to switch between display modes, to set parameter values and to adjust background illumination.
Introduction | 5
6 | Introduction
Blank page
2 Installation
Location of the unit
The RPM70/RPM80 and SP70/SP80 instruments should be mounted with special regard to the unit’s environmental protection, temperature range and cable length. Refer to the Specifications chapter.
Avoid mounting the unit where it is easily exposed to sunlight, as this may unintendedly overheat the unit.
For RPM70 and SP70 a weather cover is included and the cover should be put on when the unit is not in use.
Panel mounting
The mounting surface must be flat and even to within
0.5 mm.
1
2
3
Drill 4 mounting holes and make a panel cut-out according to the drilling template included in the package
Use the supplied self tapping screws to secure the unit to the panel
Apply the front corners
Do not over-tighten the screws!
Installation | 7
1
Cable connection and interface
Signal input, network and power supply are wired to the enclosed terminal block that is to be plugged in on the rear side.
The instrument is delivered with a 0.3 m SimNet cable with a standard SimNet plug in both ends. One plug must be cut off and the wires connected to terminals 3 through 6 according to the color codes shown below.
TERMINAL
NO
1
2
5
6
3
4
7
8
9
SIGNAL TYPE
GND
VCC
-
Supply
+ Supply 12 - 24V DC
SimNet - H “High” signal line
SimNet - C Power source common
SimNet - L “Low” signal line
SimNet - S Power source positive
NC Not connected
NC
NC
Not connected
Not connected
COLOR
-
-
Yellow
Black
Blue
Red
-
-
-
Any voltages other than those specified in the product specification, page 19, may cause damage to the instrument.
8 | Installation
Securing the cables
Use the enclosed tie wrap to secure the cables to the instrument.
Interconnecting instruments
Interconnect a series of instruments by using a SimNet power cable with termination and T-joiners as illustrated below.
Instrument
Supply 12-24V
SimNet
Supply
(Red disk)
12V
SimNet
T-joiner
SimNet
T-joiner
SimNet
T-joiner
If the instruments are connected to other SimNet compatible products, refer to the manual for those products.
Use only 12V as SimNet supply!
Installation | 9
MAIN MODE
RPM70/RPM80:
RPM
INDICATION
SP70/SP80:
SPEED
INDICATION
Installation setup
After installation, the system must be configured to read the preferred input signal before the instrument is ready for use.
The Installation Setup is accessed as shown in the illustration.
10 s
MODE
SETUP
+
SELECT
5 s
MODE
SETUP
+
SELECT
INSTALLATION SETUP
SELECT
Pointer indication
SIGNAL
INPUT
SimNet
MODE
SETUP
Demo
Save selection
1 s
MODE
SETUP
+
SELECT
RESET
Refer also to the Operation flow chart in the Operation section.
Input signal type
SimNet and Demo mode are selectable inputs on the
RPM70/RPM80 and SP70/SP80.
In Demo mode the instrument simulates data to be distributed on the SimNet.
Use the right button to select signal type. The pointer position will change accordingly as shown in the table.
Press both keys simultaneously to save the input signal type.
Local SimNet reset
When SimNet is selected as Signal Input you can reset the SimNet input sources by pressing both keys simultaneously.
Press both keys for 5 seconds to return to Main mode.
10 | Installation
3 Operation
Turning indicators on
The indicators have no power key, and will be running as long as power is applied.
When power is applied to the system the instrument will operate in the main mode.
After approximately 3 seconds the instrument is operative.
Before the instrument is ready to operate the default settings should be checked and changed if other values are preferred. Refer to the Changing the default settings chapter.
KEY
MODE
SETUP
SELECT
MODE
SETUP + SELECT
Using the keys
The instrument is operated by the 2 keys on the front.
They are used to switch between display modes, to set values and to adjust the illumination as illustrated in the table below.
Key presses or key combinations not indicated in the table have no effect.
Refer also to Operation flow chart.
KEY
PRESS
MODE/ACTION
DISPLAY MODE SETUP MODES
3 sec.
Switch to User Setup Switch to main display
Short
Short
Increase light level
Select parameter
Adjust parameter
Save setting and return to
Setup parameter
5 sec Return to main display
Time out from User Setup is 10 sec. Time out from
Installation Setup is 5 min.
Operation | 11
SELECT
Backlighting
The backlighting is adjusted by pressing the Light key when the instrument is in normal operation.
The light setting affects the keys and the backlight as shown in the table:
LIGHT LEVEL
0
1-7
8
9
KEYS
Low
Steps
Medium
High
BACKLIGHT
Off
Steps
Off
Off
Level 8 and 9 are for bright daylight.
The instrument will return to normal operation 1 second after the last key press.
Range: 0 - 9 Default value: 2
If several instruments are connected via SimNet, the instruments can be grouped in different light banks. Changing the backlight settings on one of the instruments will affect all instruments in the group. Refer to Light bank selection in Changing the default settings chapter.
Error Alarm
In the event the error indicator is lit, the instrument is not operable and service/repair is required.
Error indicator
12 | Operation
Maintenance
The IS70/IS80 instruments are “repair by replacement” units, and the operator is therefore required to perform only a very limited amount of preventive maintenance.
If the unit requires any form of cleaning, use fresh water and a mild soap solution (not a detergent). It is important to avoid using chemical cleaners and hydrocarbons such as diesel, petrol etc.
If a weather cover is available this should be put on when the unit is not in use.
Operation | 13
14 | Operation
Operation flow chart
4 Changing the default settings
General
The factory default settings may all be changed in the
User setup, accessed as shown in the illustration.
Refer also to the Operation flow chart in the Basic
Operation chapter.
MAIN MODE
Light bank selection
The light bank function is used to globally control light settings for a group of units that are connected via the
SimNet network.
By assigning several units to the same group, the light adjustment on one unit will be effective on the rest of the members in the same group.
USER SETUP
3 s
Pointer Light bank Save selection
RPM70/RPM80:
RPM
INDICATION
MODE
SETUP
LIGHT
BANK
SELECTION
Simrad
Group 1
SP70/SP80:
SPEED
INDICATION
SELECT
When selecting a light bank a beep is heard
Group 2
Group 3
Group 4
Group 5
Group 6
None
1 s
MODE
SETUP
+
SELECT
Default value: Simrad
If you prefer one instrument to stay outside any group for independent light adjustment, you select “none”.
Changing the default settings | 15
16 | Changing the default settings
Blank page
5 Spare parts
Spares and auxiliaries
Part no.
27107655
27107663
27107671
27107689
27107697
27107705
27107713
27107721
Description
RPM80 instrument head, 0-3000 RPM
RPM80 instrument head, 0-6000 RPM
RPM70 instrument head, 0-3000 RPM
RPM70 instrument head, 0-6000 RPM
SP80 instrument head, 0-25 kts
SP80 instrument head, 0-50 kts
SP70 instrument head, 0-25 kts
SP70 instrument head, 0-50 kts
Mounting kit including:
- 4 screws
- 6 corners
22096515
22098495
- 1 terminal block
IS70 Weather cover
NMEA0183 Interface cable 2.5 m (8’)
SimNet cables and accessories
Part. no.
24005829
24005837
24005845
24005852
24005860
24006298
24006306
24005878
Description
0.3 m (1’) SimNet cable (SDC:0.3M)
2 m (6.6’) SimNet cable (SDC:02M)
5 m (16.6’) SimNet cable (SDC:05M)
10 m (33’) SimNet cable (SDC:10M)
SimNet T-joiner (SDJ) (3p)
SimNet Multijoiner (7p)
SimNet Bulkhead T-connector
SimNet cable gland
Spare parts | 17
18 | Spare parts
Part. no.
24005886
24005894
24005902
24005910
24005936
24005944
24005928
24005729
24006199
24006363
Description
SimNet protection plug
SimNet termination plug
2 m (6.6’) SimNet power w/termination
2 m (6.6’) SimNet power w/o termination
AT10 Universal NMEA0183 converter
AT15 Active T-connector, IS15
SimNet cable protection cap
SimNet to Micro–C male, 0,5 m cable that connects a SimNet product to a NMEA2000 network
SimNet to Micro-C female, 1 m cable that connects a NMEA2000 product to SimNet
SimNet cable, 5.5 m (18’), with 1 plug
6 Specifications
Technical specifications
Power supply ....................................12/24V DC (+30%, -10%)
Power consumption .......................................................< 5W
SimNet network load ...................................................... 1 NL
Input signals:
NMEA2000/SimNet ....................................... 1 can channel
Input mode selection: ..........................NMEA2000/SimNet,
Demo mode
Weight: ....................................................... 0.55 kg (1.21 lb)
Material: .......................................................ASA/PC Luran S
Color: .......................................................................... Black
Display:
Dial RPM70/RPM80: ...........0 - 3000 r/min. or 0 -6000 r/min.
Dial SP70/SP80: ............................ 0 - 25 kts or 0 - 50 kts.
Illumination:.................................... Adjustable in 10 steps
Environmental protection:
Front ....................................................................... IP66
Back: ...................................................................... IP20
Optional Back cover .................................................. IP66
Safe distance to compass:
Steering compass .................................... 0.40 m (1.32 ft.)
Stand-by/Emergency distance ................... 0.20 m (0.66 ft.)
Temperature:
Operating: ............................. -15 to +70°C (+5 to +158°F)
Storage: ...............................-40 to +80°C (-40 to +176°F)
Climate
Max 95% RH: ................................... Max 30 days per year
Max 85% RH: ........................................... Remaining days
Max 75% RH: ......................................... Average per year
Specifications | 19
Dimensional drawing
172 mm [6.78"]
21 mm [0.83"]
47 mm [1.86"]
10 mm [0.37"]
152 mm [5.98"]
136 mm [5.35"]
20 | Specifications
RPM80 and SP80 indicators
115 mm [4.5"]
97 mm [3.8"]
90 mm [3.5"]
21 mm [0.8"]
47 mm [1.9"]
80 mm [3.1"]
75 mm [3.0"]
With Optional IP66 Back Cover
RPM70 and SP70 indicators
21 | Specifications
22 | Specifications