Series Half-Rack Audio Power Amplifiers • Setup Guide

(XPA 1002, XPA 1002 Plus, XPA 1002-70V, XPA 1002-100V, XPA 2001-70V, XPA 2001-100V)

WARNING: Installation and service must be performed by experienced personnel only.

AVERTISSEMENT : L’installation et l’entretien doivent être effectués par le personnel autorisé uniquement.

This guide provides startup instructions for an experienced installer to set up and operate the XPA 1002 or XPA 2001 series audio power amplifiers. All references are to the XTRA Series Half-Rack user guide which can be found on www.extron.com

.

Step 1 — Powering Down Equipment

Be sure that power to the amplifier is turned off first.

NOTE: Adjust the audio level to = (full attenuation) prior to powering the amplifier in step 7.

Turn off all other equipment and disconnect the power cables. Verify that the amplifier is disconnected from the power source before proceeding.

Step 2 — Mounting and Applications

For diagrams of typical application examples, see Application Examples in the user guide. For further mounting instructions, see

Mounting the XTRA Series Amplifier in the user guide.

Step 3 — Captive Screw Audio Cable Wiring

NOTE: Control signal ground pins may be labeled as , , or “G”. Audio ground pins may be labeled as or .

The wiring and function are the same, whichever way your product is labeled.

Wire the source output to the amplifier input 3.5 mm captive screw connectors as shown in the following illustration.

NOTE: The output power of the XPA 1002 and XPA 1002 Plus can be effectively doubled by using only one source channel and bridging the output. The XPA 1002 and XPA 1002 Plus output 200 watts @ 8 ohms in bridged mode (see Bridged

Mono Output in the user guide for wiring instructions when bridging the XPA 1002 or XPA 1002 Plus).

Tip

Sleeve

Unbalanced Dual Mono Input

XPA 1002, XPA 1002 Plus

XPA 1002-70V/100V

Tip

Sleeve

Balanced Dual Mono Input

XPA 1002, XPA 1002 Plus

XPA 1002-70V/100V

Tip

Sleeve

Tip

Sleeve

Unbalanced Stereo Input

Tip

Ring

Sleeves

Tip

Ring

Balanced Stereo Input Do not tin the wires!

NOTE: For mono input on the XPA 1002-70V/100V and 2001-70V/100V models, only the left channel needs to be wired; no jumpering to the right channel is needed. The left and right inputs of these models are summed internally to mono.

Step 4 — Speaker Wiring

Wire the speakers to the output connector of the amplifier using the included 4 pole

(XPA 1002, XPA 1002 Plus, XPA 1002-70V/100V) or 2 pole (XPA 2001-70V/100V) captive screw connector as shown to the right.

1 2

XPA 1002,

XPA 1002 Plus

XPA 1002-70V/100V

XPA 2001 Series

Step 5 — Setting the High Pass Filter (HPF)

On XPA 1002-70V/100V and XPA 2001-70V/100V models, use a Tweeker to toggle the high pass filter switch between off (no filtering) and 80 Hz (default). Setting the switch to 80 Hz prevents the saturation of speaker input transformers by low frequency signals.

NOTE: The high pass filter switch may be labeled one of two ways (see the images to the right). The function is the same, whichever way your product is labeled.

HPF

80 Hz

OFF

Step 6 — Control Wiring

On the XPA 1002, XPA 1002 Plus, XPA 2001-70V, and the XPA 2001-100V models, the 3.5 mm 5-pin captive screw remote control port (shown to the right) is used to control volume and standby mode through contact closure. Standby mode turns off all output, although the XPA is still receiving power.

For detailed wiring instructions, see the user guide.

NOTES:

• Set the volume control on the connected control device to maximum and ensure that the amplifier is not forced into standby mode via the standby pin.

• The remote control port may be labeled one of two ways (see images to the right).

The wiring and function are the same, whichever way your product is labeled.

10V

REMOTE

50mA

V C G

G

On the XPA 1002-70V and XPA 1002-100V models, the 3.5 mm 2-pin captive screw remote control port

(shown to the right) controls the standby mode only.

Step 7 — Powering On Equipment

ATTENTION: The amplifier must be powered on last.

ATTENTION : L’amplificateur doit être mis sous tension en dernier.

Reconnect all power cables and switch on all other equipment before powering on the power amplifier.

The front panel power LED of the amplifier lights green.

Step 8 — Adjusting Attenuation

Adjust the audio attenuation using the rear panel adjustment potentiometers as shown below

(see Rear Panel Features and Operation in the user guide for more information).

NOTE: On some models, this adjustment is referred to as “level”. The function is the same, whichever way your product is labeled.

or

HPF

80 Hz

10V 50 mA

VOL/MUTE

1 2 3 4 5

G

OFF

STANDBY

REMOTE

ATTENUATION

1

14

12

18

26

10

8

0

2

6

2

4

14

12

10

8

0

6

2

4

ATTENUATION

14

12

18

26

10

8

0

6

2

4

XPA 1002 Series XPA 2001 Series

1

LEVEL

2

0

XPA 1002

0

LEVEL

0

XPA 2001 Series

Step 9 — Checking the LEDs

Check the limiter/protect and signal LEDs located on the front and rear panels if problems are encountered

(see Rear Panel Features and Operation in the user guide for more information).

Extron Headquarters

+ 800.633.9876 Inside USA/Canada Only

Extron USA - West

+1.714.491.1500 +1.919.850.1000

+1.714.491.1517 FAX

Extron USA - East

+1.919.850.1001 FAX

Extron Europe

+800.3987.6673

Inside Europe Only

+31.33.453.4040

+31.33.453.4050 FAX

Extron Asia

+65.6383.4400

+65.6383.4664 FAX

Extron Japan

+81.3.3511.7655

+81.3.3511.7656 FAX

Extron China

+86.21.3760.1568

+86.21.3760.1566

FAX

Extron

Middle East

+971.4.299.1800

+971.4.299.1880 FAX

Extron Korea

+82.2.3444.1571

+82.2.3444.1575 FAX

Extron India

1.800.3070.3777

Inside India Only

+91.80.3055.3777

+91.80.3055 3737

FAX

© 2014 Extron Electronics All rights reserved.

www.extron.com

68-2354-50 Rev. B

06 14

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement