Venmar 20-minute lighted push button Air Exchangers Accessory User guide
PDF
سند
تبلیغات
تبلیغات
USER GUIDE MAIN AND AUXILIARY WALL CONTROLS 22006 rev. 04 TABLE OF CONTENTS 1. GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . 2 2. MAIN CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . 3-19 2.1 ALTITUDE/PLATINUM . . . . 2.2 X-TOUCH/GOLD-TOUCH . . 2.3 DECO-TOUCH . . . . . . 2.4 SIMPLE-TOUCH . . . . . . 2.5 LITE-TOUCH . . . . . . . 2.6 CONSTRUCTO AND BRONZE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7 . 8-13 . 14-17 . . 18 . . 18 . . 19 3. AUXILIARY CONTROLS . . . . . . . . . . . . . . . . . . . . . 20-22 3.1 20/40/60-MINUTE PUSH BUTTON . 3.2 20-MINUTE LIGHTED PUSH BUTTON 3.3 DEHUMIDISTAT . . . . . . . . . . 3.4 60-MINUTE MECHANICAL TIMER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 20 21 22 4. TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . 23-24 1. GENERAL INFORMATION Although all main controls have their own characteristics, they share some common modes, such as ventilation in low speed, ventilation in high speed, etc. Following are what we suggest regarding the use of operating modes of you main wall control: Low speed ventilation: For normal daily operation. High speed ventilation: Use occasionaly, when excess pollutants and humidity are produced (parties, odors, smoke, etc.) Recirculation: Select this mode when you deem the inside air is too dry in heating season, or too humid during cooling season. In this mode, the unit stops exchanging with the outdoors and recirculates indoor air. Intermittent: (also called 20 min/h) Select this mode when you are away for a few days, or when you deem the indoor air is too dry in heating season, or too humid during cooling season. In this mode, the unit is OFF for 40 minutes per hour and ventilates at minimum speed the remaining 20 minutes of the hour. Dehumidistat An air exchanger is not a dehumidifier, neither a humidifier, but it can exhaust excess humidity produced by human activities such as showers, cooking, parties, etc. During the heating season, air from outdoors is drier than indoor air; when enabling the dehumidistat, if the relative humidity (RH) in the house exceeds the RH setting chosen, the ventilation unit will exchange in high speed until the target indoor RH setting is reached. Select a target RH between 30% and 55%. When outdoor relative humidity is high (e.g. in summer), turn off the dehumidistat. 2 2. MAIN CONTROLS 2.1 ALTITUDE/PLATINUM MODE PREF SET SMART VC0100 WALL CONTROL KEYS AND INDICATORS MODE/PREF KEY MODE PREF MODE PREF Press this key to select whether Ventilation mode (air exchange with the outdoors), Recirculation mode (air recirculation within the house) or Program mode (the operation of the ventilation unit is customized by the user. Refer to HOW TO SET PERIODS FOR PROGRAM MODE section). Press and hold this key for 3 seconds to access Preference setting menu. 3 SEC. ARROW KEYS Use the arrow keys to: OR • Select ventilation and recirculation speeds. • Review the programmed periods. • Select Preference and Program values. 8 SEC. Press on Up arrow key for 8 seconds to display interior relative humidity level (in percentage). SET SET KEY Press and hold this key for 3 seconds to access setting periods for Program Mode. Press this key to confirm the chosen option and go to the following setting. SMART KEY Press this key to enable and disable the SMART mode. SMART The SMART mode uses indoor relative humidity level, outdoor temperature, and minimum and maximum outdoor temperature chosen values to manage the air exchange with the outdoors, in order to enhance comfort in the house. POWER INDICATOR This indicator illuminates when the control powered on. 3 2. MAIN CONTROLS (CONT’D) 2.1 ALTITUDE/PLATINUM (CONT’D) WALL CONTROL KEYS AND INDICATORS (CONT’D) FILTER MAINTENANCE INDICATOR This indicator illuminates when it is time to perform the ventilation unit filter maintenance (refer to the ventilation unit user guide). Once the filter maintenance is done, reset the filter maintenance indicator as follow: BOTH DURING 5 SEC. Press simultaneously on both MODE/PREF key and SET key for 5 seconds to turn off the filter maintenance indicator light. SET MODE PREF HOW TO SET PREFERENCES In order to benefit from all of the features of your wall control, the preferences must be set. Table below shows all available settings. SETTING AVAILABLE VALUES DEFAULT OPTION CURRENT DAY MON/TUE/WED/THU/FRI/SAT/SUN MON HOUR DISPLAY AM 12:00 PM OR 24:00 12:00 AM PM CURRENT HOUR CURRENT MINUTE TEMPERATURE UNIT INSIDE TEMPERATURE DISPLAY MINIMUM OUTDOOR TEMPERATURE FOR AIR EXCHANGE1 MAXIMUM OUTDOOR TEMPERATURE FOR AIR EXCHANGE1 FROM 0 TO 12 OR 24 12 FROM 00 TO 59 00 °C OR °F °C ON OR OFF ON -40°C TO 0°C -25°C OR OR -40°F TO 32°F -13°F 1°C TO 40°C 27°C OR OR 33°F TO 104°F 81°F 1IN PROG OR SMART MODE, THESE LIMIT VALUES ALLOW TO STOP AIR EXCHANGE WITH THE OUTDOORS FOR BETTER COMFORT IN THE HOUSE. BACKLIGHT COLOR BLUE OR GREEN BLUE BACKLIGHT DISPLAY2 AUTO OR ON AUTO 2AUTO: BACKLIGHT ACTIVATED 10 SECONDS WHEN ANY KEY IS PRESSED. ON: BACKLIGHT ALWAYS ON. OFF MODE FOR INTERMITTENT MODE3 VENTILATION/LOW SPEED RECIRC., VENTILATION/HIGH SPEED RECIRC., OR VENTILATION/OFF VENTILATION/OFF 3AFTER A VENTILATION PERIOD, DETERMINES THE SECOND PART OF THE CYCLE (OFF, RECIRCULATION ON LOW SPEED OR RECIRCULATION ON HIGH SPEED). NOTE: RECIRCULATION ON LOW SPEED IS NOT AVAILABLE TO SOME EARLIER VENTILATION UNIT MODELS. REFER TO COMPABILITY CHART INCLUDED WITH WALL CONTROL. 4 2. MAIN CONTROLS (CONT’D) 2.1 ALTITUDE/PLATINUM (CONT’D) SETTING PREFERENCES PROCEDURE NOTE: While setting Preferences, the corresponding setting value flashes (e.g.: while setting current hour, hour is flashing). Press and hold MODE/PREF key for 3 seconds to access the setting menu. MODE PREF 3 SEC. The software version will flash on screen alternally (2 set of digits). MODE PREF SET SMART SET Press SET key to start setting. The current day will be the first setting to be made: MON (for Monday) will flash on screen. MODE PREF SET SMART Use the arrow keys to select value. OR Press SET key to confirm the selected preference and go to next setting. SET NOTE: You can exit Preferences setting by pressing on MODE/PREF for 3 seconds any time in the process, or wait 60 seconds. The modified values will be kept in memory. POWER FAILURE After a power failure a booting sequence will occur, then the wall control returns to its original settings. However, if the power failure duration is more than 4 hours, the wall control looses only its day and time settings memory (these must be reprogrammed). The rest of the preferences and settings is kept in permanent memory. 5 2. MAIN CONTROLS (CONT’D) 2.1 ALTITUDE/PLATINUM (CONT’D) HOW TO SET PERIODS FOR PROGRAM MODE The Program Mode allows the user to customize the operation of his/her ventilation unit, for week and weekend days. All days are divided in 4 periods. The periods starting hour and ventilation speed are factory set (see below). PERIOD PERIOD 1 (MORNING) PERIOD 2 (DAY) PERIOD 3 (EVENING) PERIOD 4 (NIGHT) DAILY PERIODS DEFAULT SETTINGS STARTING HOUR 6:00 AM 9:00 AM 5:00 PM 11:00 PM MODE MIN 20 MIN/H MIN 20 MIN/H TO CHANGE THESE VALUES: SET Press SET key for 3 seconds. 3 SEC. PROG (for Program) will appear on screen and week days will flash. NOTE: If the week days were the first to be set, the weekend days will appear on screen; but if the weekend days were the first to be set, then the week days will appear on screen. MODE PREF SET SMART OR SET Use the arrow keys to select between week days or weekend days. Press SET key to confirm the choice and go to setting daily period 1. Period 1 will appear on screen and hour display will flash. MODE PREF SET SMART Use the arrow keys to select the period starting hour. OR NOTE: Time changes by 15-minute increments. 6 2. MAIN CONTROLS (CONT’D) 2.1 ALTITUDE/PLATINUM (CONT’D) HOW TO SET PERIODS FOR PROGRAM MODE (CONT’D) SET Press SET key to confirm the choice and go to select the ventilation speed or type. Ventilation speeds and type will flash. MODE PREF SET SMART OR SET Use the arrow keys to select the ventilation speed or type. Press SET key to confirm the choice and go to setting Daily Period 2. Period 2 will appear on screen and hour display will flash. Proceed as for Period 1 for all daily periods. Once the ventilation speed or type for Daily Period 4 has been selected: SET Press SET key to confirm and go to weekend days. Weekend days and period 1 will appear on screen and hour will flash. MODE PREF SET SMART Set weekend days periods as for week days. TO EXIT SETTING PERIODS SET 3 SEC. Press SET key for 3 seconds. ALTITUDE AND PLATINUM RESET PROCEDURE VQ0048A BOTH DURING 8 SEC. The wall control must be reset if it was previously connected to another ventilation unit. To perform the reset: Press simultaneously on both arrow keys for 8 seconds. Unplug the ventilation unit for 30 seconds. Plug back the ventilation unit in power source. 7 2. MAIN CONTROLS (CONT’D) 2.2 X-TOUCH/GOLD-TOUCH LCD screen. Backlight: If the backlight is not illuminated, the first key pressed (no matter which key) will turn on the backlight. The backlight remains illuminated for 10 seconds after the last key is pressed. STANDBY mode* MODE key MODE % HUM key % HUM TURBO TURBO function key VC0166 * STANDBY mode is the factory set default mode. When the unit is on standby mode, it will only respond to override wall control (if present). Only the house icon appears on LCD screen. On other operation modes, the house icon is still there, and the label mode in which the unit operates appears at right of LCD screen. INDICATORS PROTECTION MODE INDICATOR This icon appears to show when the ventilation unit is in Protection Mode. This special mode has been created to protect the ventilation unit from specific conditions (e.g.: outdoor temperature colder than -25°C). There is no action to be taken when this icon appears, it will disappear by itself. AUXILIARY CONTROL IN USE INDICATOR When a 20/40/60 minute auxiliary control is activated, its operation overrides the X-Touch control operation and a chronometer icon is displayed. This icon disappears when the 20/40/60 minutes auxiliary control cycle is done. CONT MAINTENANCE INDICATOR MODE CONT AND TURBO This icon flashes when it is time to peform the ventilation unit maintenance. Refer to the ventilation unit user guide. Once the unit maintenance is done, press simultaneously on both MODE and TURBO keys to reset the maintenance indicator. This will erase the icon from the screen. 8 2. MAIN CONTROLS (CONT’D) 2.2 X-TOUCH/GOLD-TOUCH (CONT’D) OPERATING MODES MODE Press the Mode key to choose the operation mode of the ventilation unit (except TURBO mode). Operating Mode will then appear on LCD screen (STANDBY, RECIRC, 20 min/h, CONT, SMART). STANDBY Put the unit on stand-by mode, so it will only respond to override wall controls (if present). On LCD screen, only the House is visible showing the control is powered on. This is the factory set default mode. RECIRC Air is recirculated inside the house on high speed. 20 MIN/H The ventilation unit exchanges air intermittently on a one hour cycle as follows: OFF for 40 min. (or recirculation for 40 min. on low or high speed, see Settings) and then exchange air during 20 min. on low speed. Repeat cycle after the 20 min. of air exchange. CONT CONT Air is exchanged with the outdoors at the minimum blower speed. 9 2. MAIN CONTROLS (CONT’D) 2.2 X-TOUCH/GOLD-TOUCH OPERATING MODES (CONT’D) SMART Air exchange is managed according to indoor humidity measured by the wall control and outdoor temperature. In SMART mode, the SMART icon appears as well as the current operating mode called by SMART (see below). TURBO CONT TURBO mode called by SMART mode CONT mode called by SMART mode 20 min/h mode called by SMART mode ECO mode STANDBY called by mode SMART mode called by (see NOTE) SMART mode NOTE: The ECO mode set the unit operation to STANDBY for 50 minutes (or in RECIRC mode for 50 minutes; see settings section) and then exchange air during 10 minutes on low speed. This mode is exclusively activated by SMART mode. The chart below shows the operating modes called by SMART mode, according to the indoor humidity percentage and the outdoor temperature. OUTDOOR TEMPERATURE 80% From -35°C From -25°C From -15°C to -25°C to -15°C to -5°C From -5°C to 5°C From 5°C to 15°C From 15°C to 25°C From 25°C to 35°C * INDOOR HUMIDITY LEVEL 70% TURBO 60% 50% CONT 40% 30% 20% * THIS AREA REPRESENTS STANBY MODE. 10 2. MAIN CONTROLS (CONT’D) 2.2 X-TOUCH/GOLD-TOUCH (CONT’D) FUNCTIONS TURBO FUNCTION TURBO TURBO Press the TURBO function key to turn the unit on air exchange in high speed during 4 hours, then, the unit will get back to its previous operation mode. The TURBO icon is flashing during the 4-hour cycle. To exit this function before the end of its 4-hour cycle, press on TURBO or MODE key; the unit will get back to its previous operation mode. 3 sec. TURBO TURBO Press and hold the TURBO function key during 3 seconds to turn the unit on air exchange in high speed continuously. The TURBO icon appears and stay continuously. To exit this TURBO mode, press on TURBO or MODE key; the unit will get back to its previous operation mode. DEHUMIDISTAT FUNCTION CONT The dehumidistat function has been created to manage the indoor relative humidity excess. When the actual home Relative Humidity percentage (RH %) detected is over the set value, drops appears on screen and the control overrides the current mode, turning on the unit on high speed exhange until the indoor relative humdity % set is reached. The unit then returns to its previous operation setting. Refer below to find out how to set the indoor relative humidity %. HOW TO ENABLE AND DISABLE THE DEHUMIDISTAT FUNCTION: CONT In all modes except STANDBY and SMART, press the % HUM key to enable the dehumidistat function. % HUM % HUM The actual home RH % level appears on screen (enabled). CONT 11 Press once more on the % HUM key to disable the dehumidistat function. The actual home RH% level disappears from screen (disabled). 2. MAIN CONTROLS (CONT’D) 2.2 X-TOUCH/GOLD-TOUCH (CONT’D) SETTINGS HOW TO SET THE INDOOR RELATIVE HUMIDITY (RH %) LEVEL 3 sec. % HUM % HUM Press and hold the % HUM key for 3 seconds. Press the % HUM key to change the value. Lower value: 30%. Higher value: 56%. The actual RH% level appears on screen. Default value: 44% 3 sec. % HUM The value changes by 2% increments. To exit this seting menu, press and hold the % HUM key for 3 seconds OR wait 10 seconds. HOW TO SET THE UNIT OPERATION IN THE REMAINING 40 MINUTES ON 20 MIN/H MODE AND HOW TO SET THE UNIT DEFROST CYCLE TYPE 3 sec. MODE Press and hold the MODE key for 3 seconds. The LCD screen will show one of these configurations: TURBO CONT OR OR The small triangle and two lines flash to show STANDBY (default configuration setting). Recirculation arrows turn while the small triangle, rE and CONT label flash to show RECIRCULATION on low speed. Recirculation arrows turn while the small triangle, rE and TURBO label flash to show RECIRCULATION on high speed. OR TURBO 12 % HUM MODE Use MODE or TURBO key to see all 3 configurations. Press % HUM key fo accept chosen configuration and go to setting defrost cycle type. 2. MAIN CONTROLS (CONT’D) 2.2 X-TOUCH/GOLD-TOUCH (CONT’D) SETTINGS (CONT’D) HOW TO SET THE UNIT OPERATION IN THE REMAINING 40 MINUTES ON 20 MIN/H MODE AND HOW TO SET THE UNIT DEFROST CYCLE TYPE (CONT’D) The LCD screen will show one of these three defrost cycle types: OR Sd (Standard) appears over snowflake icon (default cycle setting). When needed, the unit will perform defrost cycle on high speed. NOTE: This is the defrost type used for the data published by HVI and ENERGY STAR®. OR PL (Plus) appears over snowflake icon. Use this cycle in cold region (outdoor temperature -27°C [-17°F] and lower). When needed, the unit will perform defrost cycle on high speed on a longer period of time. dI (Discretion) appears over snowflake icon. When needed, the defrost cycle will be performed on the same speed than the unit ventilation speed. (e.g.: if the unit is set on TURBO, the defrost cycle will be done on high speed, and if the unit is set on CONT, the defrost cycle will be done on low speed. OR TURBO % HUM MODE Use MODE or TURBO key to see all 3 defrost cycle types. Press % HUM key to accept chosen defrost cycle type and go to software version display. % HUM LCD screen alternates between the house with circling arrows and the house without arrow. The numbers under the house are the software version number. 13 Press % HUM key OR wait 10 seconds to exit user setting menu. 2. MAIN CONTROLS (CONT’D) 2.3 DECO-TOUCH VC0153 OR OR BACKLIGHT If the backlight is not illuminated, the first UP or DOWN arrow button pressed will turn on the backlight. The backlight remains illuminated for 10 seconds after the last button is pressed (no matter the button). OK BUTTON Press on OK button to enable or disable the dehumidistat override and to confirm settings. OPERATING MODES To change the operation mode of the ventilation unit, press the UP or DOWN arrow button. Operating mode label will then scroll up or down on LCD screen. OFF Put the unit on stand-by mode, so it will only respond to auxiliairy controls (if present). On LCD screen, only the House is visible showing the control is powered on. This is the factory default mode. RECIRC Air is recirculated inside the house. NOTE: Recirculation is not available on some ventilation unit models (refer to compability chart included with Deco-Touch wall control). 20 MIN/H The ventilation unit exchanges air intermittently on a one hour cycle as follows: OFF for 40 min. (or recirculation* for 40 min., see page 11) and then exchange air during 20 min. on low speed. Repeat cycle after the 20 min. of air exchange. * Recirculation is not available on some ventilation unit models (refer to compability chart included with Deco-Touch wall control). MIN Air is exchanged with the outdoors on low speed. MAX Air is exchanged with the outdoors on high speed. 14 2. MAIN CONTROLS (CONT’D) 2.3 DECO-TOUCH (CONT’D) DEHUMIDISTAT OVERRIDE SELECTION To engage the humidity override, press OK. The actual indoor RH and the %HUM label appear on LCD screen. NOTE: If the actual RH is less than 20%, then the humidity indicator will display “LO”, and if the actual RH is greater than 80%, then the humidity indicator will display “HI”. When the dehumidistat override is activated, the AUTO indicator will appear on LCD screen to show that the actual mode is being overridden. Also, the relative humidity appears (if it was not shown, see example at left). Once the target humidity level is reached, the unit goes back into its original operating mode and AUTO disappears from LCD screen. NOTE: If the actual mode is MAX, only the relative humidity level appears on screen, AUTO label will not appear. To turn off the dehumidistat override, press OK again. The RH and %HUM display will disappear from LCD screen. POWER FAILURE After a power failure, the wall control returns to its original operation mode. All settings are kept in memory. MAINTENANCE INDICATOR Resetting Maintenance Indicator: Press simultaneously on both arrow buttons, maintenance indicator will disappear from LCD screen. The maintenance indicator is represented by an M in a rounded triangle, at the top of the house (see at right). If this indicator is flashing, perform the regular maintenance, and if it is not flashing, perform the annual maintenance (refer to the ventilation unit user guide). AND DECO-TOUCH RESET PROCEDURE The wall control must be reset if it was previously connected to another ventilation unit. To perform the reset: 8 sec. Unplug the ventilation unit for 30 seconds. Press simultaneously on DOWN arrow and OK buttons for 8 seconds. 0062 Plug back the ventilation unit in power source. 15 2. MAIN CONTROLS (CONT’D) 2.3 DECO-TOUCH (CONT’D) HOW TO SET THE RELATIVE HUMIDITY (RH) LEVEL AND CHOOSE BETWEEN OFF IN STANDBY OR RECIRCULATION IN STANDBY Setting the relative humidity level allows to select the maximum desired indoor humidity level (in percentage). This value will be used to start the dehumidistat override (air exchange in high speed). 3 sec. Press and hold OK for 3 seconds to access the settings menu. The backlight will be activated during all the procedure. The relative humidity arrow and value will flash (default setting: 45%). Use UP or DOWN arrow to change the value. The value changes by 1% increments. Lower value: 30%. Upper value: 55%. Still flashing. OR OR Press OK button to accept the new value and go to next settting. NOTE: Steps described in dotted square are not available to all units. Refer to compability chart included with Deco-Touch wall control. 16 2. MAIN CONTROLS (CONT’D) 2.3 DECO-TOUCH (CONT’D) HOW TO SET THE RELATIVE HUMIDITY (RH) LEVEL AND CHOOSE BETWEEN OFF IN STANDBY OR RECIRCULATION IN STANDBY (CONT’D) The LCD screen will show one of these configurations: OR Recirculation arrows are turning, rE flashes and MIN label appears to show that RECIRCULATION on low speed² is in standby. Two lines are flashing to show that OFF¹ is in standby (default configuration setting). OR OR 23 06 Recirculation arrows are turning, rE flashes and MAX label appears to show that RECIRCULATION on high speed² is in standby. Use UP or DOWN arrow to see all 3 configurations. Press OK button to accept chosen configuration. LCD screen alterates between the house wth all arrows and the house without arrow. The numbers under the house are the software version number. Press OK button to quit setting menu. ¹OFF IN STANDBY: On 20 min/h mode, the ventilation unit is OFF during 40 minutes and exchanges air with the outdoors on low speed during the remaining 20 minutes of the hour; this is the default value. 2RECIRCULATION IN STANDBY: On 20 min/h mode, the ventilation unit recirculates the indoor air for 40 minutes, on low speed or high speed, according to the setting made. During the remaining 20 minutes of the hour, the unit exchanges air with the outdoors on low speed. NOTE: Recirculation in low speed is not available to all units. Refer to compability chart included with Deco-Touch wall control. 17 2. MAIN CONTROLS (CONT’D) 2.4 SIMPLE-TOUCH S-T MAX MIN RECIRCULATION VC0154 Push on the push button; the color of the indicator shows the unit operating mode. GREEN: Recirculation YELLOW: Minimum speed ventilation RED: High speed ventilation NO LIGHT: Unit is OFF After a power failure, the Simple-Touch wall control will be OFF. 2.5 LITE-TOUCH L-T MAX MIN INTERMITTENT VC0155 Push on the push button; the color of the indicator shows the unit operating mode. GREEN: Intermittent YELLOW: Minimum speed ventilation RED: High speed ventilation NO LIGHT: Unit is OFF After a power failure, the Lite-Touch wall control will be OFF. 18 2. MAIN CONTROLS (CONT’D) 2.6 CONSTRUCTO AND BRONZE 20% 5°C 41°F MF O R T Z O N E M FO R T Z ON E RE HUM ID MO OFF MIN MAX 25% -5°C 23°F CO CO 01/98 XXXX #X 5°C 41°F - -20°C -4°F LE S S H U MI D -5°C 30% 23°F -20°C -4°F -30°C -22°F MAX. OFF MIN. CONSTRUCTO VC0156 ADJUSTING AIR SUPPLY CONTROL Use the slide switch to control air supply. OFF MIN MAX MAX. OFF MIN. MIN. MAX. OFF OFF MIN MAX OFF MIN MAX MAX. OFF MIN. Minimum speed ventilation Maximum speed ventilation. (except if knob is set below the click, see NOTE below). NOTE: When “MIN” (minimum speed) is selected, if the knob is set below the click, the unit will exchange on high speed with the outdoors until the desired humidity level has been reached. Unit is OFF. ADJUSTING DEHUMIDISTAT Rotate knob to adjust humidity control. 5°C 41°F MF O R T Z O N E M FO R T Z ON E - RE HUM ID MO -5°C 23°F -20°C -4°F CO CO 01/98 XXXX #X 5°C 41°F LE S S H U MI D -30°C -22°F -5°C 23°F -20°C -4°F 1) Determine the humidity level in your house (bring the knob counterclockwise to its maximum position, then bring it back clockwise slowly until you hear a “click”). 2) Set the knob to one line under this temperature level or “click”. CAUTION Do not select a temperature below -20°C (-4°F). This could lead to excessive dryness in the air causing discomfort for the occupants. It is possible (and normal) to experience condensation on your windows when drastic changes in temperature happen (for example: -5°C [23°F] to -20°C [-4°F]). In that case, we suggest to wait a few days to allow the situation to stabilize. 19 3. AUXILIARY CONTROLS 3.1 20/40/60 MINUTE PUSH BUTTON • Within 2 seconds, push one time for 20 minutes, two times for 40 minutes, or three times for 60 minutes air exchange on high speed. Indicator then lights up. • Every 5 seconds, the indicator light flashes one time to indicate a 20-minute selection, two times for a 40-minute and three times for a 60-minute selection. • To stop activation, push one more time. Unit then returns to its to previous setting. VC0136 After a power failure, the 20/40/60 minute push-button settings will be erased. 3.2 20-MINUTE LIGHTED PUSH BUTTON • VC0127 Press once to activate air exchange on high speed for 20 minutes; the indicator will light up. NOTE: When this control is connected to some specific ventilation unit models, its indicator may be flashing instead of being lit on permanently during the 20-minute cycle; this situation is normal. • To stop activation before the end of the 20-minute cycle, push one more time. Unit then returns to its to previous setting. After a power failure, the 20-minute cycle will be erased. 20 3. AUXILIARY CONTROLS (CONT’D) 3.3 DEHUMIDISTAT % ATI VE HUM ID IT REL Y OFF 20% 25% 70% 30% CO M FO R T Z O N E 40% 60% 50% DURING FALL, WINTER AND SPRING, SET THE DIAL ACCORDING TO THE DESIRED MAXIMUM INDOOR HUMIDITY LEVEL. DURING SUMMER SET THE DIAL TO THE OFF POSITION. VC0157 % A TI VE HUM ID I TY REL F OF 20% 25% 70% 30% CO M FO R T Z O N E 40% Rotate knob to the desired maximum indoor humidity level. 60% 50% CAUTION Do not select a humidity level below 30%. This could lead to excessive dryness in the air causing discomfort for the occupants. 21 3. AUXILIARY CONTROLS (CONT’D) 3.4 60-MINUTE MECHANICAL TIMER OFF Turn Past HOLD 10 60 20 50 40 This control activates air exchange on high speed for periods varying from 10 to 60 minutes. 30 MINUTES VC0017 22 4. TROUBLESHOOTING If the unit does not work properly, reset the unit by unplugging it for one minute and then replug it. If it still not working properly, refer to table below. CAUTION If the ventilation unit is equipped with an integrated control, turn off this control and wait until its LED is turned off before using a main wall control. PROBLEM YOU SHOULD TRY THIS 1. The error code E1 is • Check the compatibility with the ventilation unit (refer displayed on Altitude, to chart included with the control). Platinum or Deco-Touch wall • Ensure that the color coded wires have been control screen. connected to their appropriate place. • Inspect every wire and replace any that are damaged. • Ensure the wires are correctly connected. 2. The error code E3 is • Reset the wall control displayed on Altitude, (see Wall Control Reset Procedure below). Platinum or Deco-Touch wall control screen. 3. The error code E4 is • Reset the wall control displayed on Altitude or (see Wall Control Reset Procedure on next page). Platinum wall control screen. 4. The error code E7 is • Power supply problem between the unit and the wall displayed on Deco-Touch control. May be caused by wall control cable excess wall control screen. length. Contact your installer. 5. There is no outdoor NOTE: At its very start-up or after a power failure, it takes some minutes before the outdoor temperature displayed on temperature appears on screen. The delay Altitude or Platinum wall duration depends on which operation mode control screen (only a line the wall control is set. The shortest delay is ). appears obtained when the wall control is set on MIN or MAX in VENT mode. __ 6. There is no outdoor • The outdoor temperature is not shown when the temperature displayed on ventilation unit is in recirculation mode, this is normal. Altitude or Platinum wall control screen (no line). 7. An error code starting with E0 • Ensure that the color coded wires have been (E01, E02, etc.) is displayed connected to their appropriate place. on X-Touch or Gold-Touch • Ensure that the wires are correctly connected. • Press and hold simultaneously for 10 seconds on wall control screen). % HUM, MODE and TURBO keys to reset the wall control. The user preferences will have to be reset 8. An error code starting with E2 • Problem with the ventilation unit. (E21, E22, etc.) is displayed Contact your installator. on X-Touch or Gold-Touch wall control screen). 9. A 10-second countdown • Wait until the end of the countdown, is displayed on X-Touch without pressing any key. or Gold-Touch wall control screen. 23 4. TROUBLESHOOTING (CONT’D) ALTITUDE AND PLATINUM RESET PROCEDURE The wall control must be reset if it was previously connected to another ventilation unit. To perform the reset: BOTH DURING 8 SEC. VQ0048A 8 seconds. Unplug the ventilation unit for 30 seconds. Plug back the ventilation unit in power source. Press and hold simultaneously on both arrow keys for X-TOUCH AND GOLD-TOUCH RESET PROCEDURE The wall control must be reset if it was previously connected to another ventilation unit. To perform the reset: MODE 10 sec. Press and hold simultaneously for 10 seconds on % HUM, MODE and TURBO keys. NOTE: The user preferences will have to be reset. % HUM AND TURBO AND DECO-TOUCH RESET PROCEDURE The wall control must be reset if it was previously connected to another ventilation unit. To perform the reset: If the problem is not solved by the above, contact your installer. 24 8 sec. Press simultaneously on DOWN arrow and OK buttons for 8 seconds. Unplug the ventilation unit for 30 seconds. Plug back the ventilation unit in power source. 0062 ">
/
دانلود
فقط یک یادآوری دوستانه. می توانید سند را درست در اینجا مشاهده کنید. اما مهمتر از همه، هوش مصنوعی ما قبلاً آن را خوانده است. این می تواند موارد پیچیده را به زبان ساده توضیح دهد، به سوالات شما به هر زبانی پاسخ دهد و به شما کمک کند به سرعت حتی طولانی ترین یا پیچیده ترین اسناد را پیمایش کنید.
تبلیغات