Ascon tecnologic K3 V Series Quick Manual
PDF
ஆவணம்
விளம்பரம்
விளம்பரம்
2.4 K85V Series KxxV 3.3 Keyboard functions during parameters modification 0... 50/60 mV; 0... 1 V; 0/1... 5 V; 0/2... 10 V 0/4... 20 mA active Indicators with independent Timer option A short pression allows to exit the current parameter group and select a new parameter group. A long pression allows to close the configuration parameter procedure (the instrument returns to the “standard display”). Ext. gen. 4... 20 mA active 4... 20 mA passive (2 wires) OUT 10VDC (max. 20 mA) DI1 Power supply PTC-NTC Pt100 TC DI2 A B GND RS485 Digital input Relays: Out-1, 2: 8A-AC1 (3A-AC3)/250VAC Out-3: 5A-AC1 (2A-AC3)/250VAC To check the out of span Error condition, proceed as follows: When the display is showing a group, the key allows to enter in the selected group. When the display is showing a parameter, the key allows you to store the value shown and go to the next parameter within the same group. INPUT SSR: 20mA/10VDC Increases the value of the selected parameter. OUT1 www.ascontecnologic.com Ascon Tecnologic S.r.l Via Indipendenza, 56 27029 Vigevano (PV) - ITALY Tel.: +39 0381 69871 FAX: +39 0381 698730 http:\\www.ascontecnologic.com [email protected] 2.5 Mounting requirements This instrument is intended for permanent installation, for indoor use only, in an electrical panel which encloses the rear housing, exposed terminals and wiring on the back. Select a mounting location having the following characteristics: 1. It should be easily accessible; 1 - OUTLINE DIMENSIONS (mm) 1.1 K3_V Series 2. There is minimum vibrations and no impact; 3. There are no corrosive gases; 28 64 35 5.5 Brackets 29 Panel + Gasket 12 mm max. 4. There are no water or other fluid (i.e. condensation); 48 Sometimes, e.g. when you reconfigure an instrument previously used for other works or from other people or when you have made too many errors during configuration and you decided to reconfigure the instrument, it is possible to restore the factory configuration. This action allows you to put the instrument in a defined condition (in the same condition it was at the first Power ON). The default data are the typical values loaded in the instrument prior to shipping from factory. To load the factory default parameter set, proceed as follows: 1. Press the button for more than 5 seconds; 3. Using and 6. The relative humidity is in accordance with the instrument specifications (20... 85 %) 4. Push button; 1. Do not run input wires together with power cables; 98 2. External components (like zener barriers, etc.) connected between sensor and input terminals may cause errors in measurement due to excessive and/or not balanced line resistance or possible leakage currents; 44.5 9.5 3.4 Factory reset - Default parameters loading procedure 2. The display will show alternately “PASS” and “0”; 2.6 Genereal notes about wiring 1.2 K4_V Series Decreases the value of the selected parameter. Note: The group selection is cyclic as well as the selection of the parameters in a group. 5. The ambient temperature is in accordance with the operative temperature (0... 50 °C) The instrument can be mounted on panel with a maximum thick of 15 mm. When the maximum front protection (IP65) is desired, the optional gasket must be monted. 71 48 OUT2 Note: The complete manual is available, free of charge, at: Quick Guide -Code: FKxxVENG 78 OUT3 buttons, set the value -481; 5. The instrument will turn OFF all LEDs then it will show “dFLt” messages and than it turn ON all LEDs of the display for 2 seconds and than it will restart as at the first power ON. The procedure is complete (the default value of each parameter is listed in the “Parameters Tables” paragraph). 4 - ERROR MESSAGES 4.1 Out of Range Signals The display shows the OVER-RANGE and UNDERRANGE conditions with the following indications: 1. Check the signal source and the connecting line. 2. Make sure that the input signal is in accordance with the instrument configuration. Otherwise, modify the input configuration (see section 4). 3. If no error is detected, send the instrument to your supplier to be checked. 4.2 List of possible errors ErEP- Possible problem of the instrument memory. The message desappears automatically. If the error continues, send the instrument to the supplier. 5 - GENERAL NOTES 5.1 Proper Use Every possible use not described in the complete manual (www.ascontecnologic.com) must be considered as a improper use. This instrument is in compliance with EN 61010-1 "Safety requirements for electrical equipment for measurement, control and laboratory use"; for this reason it coud not be used as a safety equipment. Ascon Tecnologic S.r.l. and its legal representatives do not assume any responsibility for any damage to people, things or animals deriving from violation, wrong or improper use or in any case not in compliance with the instrument's features. 5.2 Warranty and repairs This product is under warranty against manufacturing defects or faulty materials that are found within 12 months from delivery date. The warranty is limited to repairs or to the replacement of the instrument. The tampering of the instrument or an improper use of the product will bring about the immediate withdrawal of the warranty's effects. In the event of a faulty instrument, either within the period of warranty, or further to its expiry, please contact our sales department to obtain authorisation for sending the instrument to our company. The faulty product must be shipped to Ascon Tecnologic with a detailed description of the faults found, without any fees or charge for Ascon Tecnologic, except in the event of alternative agreements. Before supplying tension to the instrument, make sure that it is perfectly dry. 3. When a shielded cable is used, it should be connected at one point only; 4. Pay attention to the line resistance; a high line resistance may cause measurement errors. Panel + Gasket 9 mm max. Bracket type 2 Bracket type 1 6. The power supply input is NOT fuse protected. Please, provide a T type 1A, 250 V fuse externally. 1.3 K85V Series 70 1 2 3 4 5 6 7 27 8 21 5. Before connecting the instrument to the power line, make sure that line voltage is equal to the voltage shown on the identification label. 12 60 45 84 e) The power supply input is NOT fuse protected. Please, provide a T type 1A, 250 V fuse externally. 2 - CONNECTIONS DIAGRAMS 2.1 K31V Series 3 - CONFIGURATION PROCEDURE 3.1 How to enter the configuration mode 0... 50/60 mV; 0... 1 V; 0/1... 5 V; 0/2... 10 V 0/4... 20 mA active 4... 20 mA active 1. Push the button for more than 3 seconds. The display will show alternately 0 and PASS; 4... 20 mA passive (2 wires) OUT 12VDC (max. 20 mA) PTC-NTC Pt100 TC/mV DI1 DI2 B WARNING! Whenever a failure or a malfunction of the device may cause dangerous situations for persons, things or animals, please remember that the plant must be equipped with additional safety devices which will guarantee safety. 4 - PARAMETERS TABLES ] InP Group (parameters relative to the inputs) no. Parameter 1 HcFG 2. Using and/or buttons set the programmed password. RS485 GND A INPUT Power supply OUT4 OUT3 SSR: 10mA/10VDC OUT2 OUT1 2.2 K38V Series RELAY: 8A-AC1 (3A-AC3)/250VAC SSR: 8mA/8VDC NC NO C C OUT1 NC NO INPUT TC/mV Pt100 PTC-NTC OUT2 Out 10VDC max. 20mA 4...20 mA passive (2 wires) 4...20 mA active Ext. gen. 0/4...20 mA active 0...50/60 mV; 0...1 V; 0/1...5 V; 0/2...10 V 2.3 K4_V Series DI1 DI2 Out1, Out2: Relay 8A-AC1 (3A-AC3)/250VAC Out3: Relay 5A-AC1 (2A-AC3)/250VAC SSR: 8mA/8VDC INPUT OUT3 Power supply OUT2 Out 12 VDC max. 20 mA 4...20 mA passive (2 wires) Ext. 4... 20 mA active gen. 0/4...20 mA active 0... 50/60 mV; 0... 1 V; 0/1... 5 V; 0/2... 10 V OUT1 a) The factory default password for configuration parameters is 30. b) The parameter changes are protected by a time out. If no key is pressed for more than 10 seconds the instrument automatically returns back to the Standard display, the new value of the last selected parameter will be lost and the parameter modification procedure closed. Sometimes can be useful to enter the parameter configuration procedure with no timeout (e.g. for the first time an instrument is configured). In this case, use a password equal to the previously set password + 1000 digits (e.g. 1000 + 30 [default] = 1030). It is always possible to manually end the parameter configuration procedure (see the next paragraph). c) During parameter modification the instrument continues to perform the Alarms and timer functions. In certain conditions, when a configuration change can produce a bump to the process, it is advisable to temporarily stop the alarm functions during the programming procedure (its alarms output will be Off). A password equal to 2000 + the programmed value (e.g. 2000 + 30 = 2030). The alarms will restart automatically when the configuration procedure will be manually closed 3. Push the button If the password is correct the display will show the acronym of the first parameter group preceded by the symbol . In other words the display will show . The instrument is in configuration mode. 3.2 How to exit the configuration mode Push button for more than 5 seconds. The instrument will come back to the “standard display”. Description Parameter available by serial link nIt shows the current hardware Range TC/RTD TC/PTC Current Volt Default Vis. Promo. According Not to the displayed Hardware Sensor selection (according to the hw) Notes: RELAYS: Out-1, 2: 8A-AC1 (3A-AC3)/250VAC RELAYS: Out-3, 4: 5A-AC1 (2A-AC3)/250VAC TC Pt100 PTC-NTC b) For supply connections use No. 16 AWG or larger wires rated for at last 75°C; d) Before connecting the instrument to the power line, make sure that line voltage is equal to the voltage shown on the identification label. 13 14 15 16 17 18 19 20 21 22 23 24 Power supply Note: When an over-range or an under-range is detected, the alarms operate as in presence of the maximum or the minimum measurable value respectively. c) Use copper conductors only; Out3 Ext. gen. Under-range Notes:Safety precautions. 9 10 11 12 a) To avoid electrical shock, connect power at last; Out1 Out2 Over-range The sensor break will be signalled as an out of range: 2 3 SEnS dP TC, Pt100 input J, crAL, S, r, t, ir.J, ir.cA, Pt1, 0... 50 (mV), 0... 60 (mV), 12... 60 (mV) J TC, PTC, NTC input J, crAL, S, r, t, Ir.J, Ir.cA, Ptc, ntc, 0... 50 (mV), 0... 60 (mV), 12... 60 (mV) Ptc Current input 0... 20 (mA), 4... 20 (mA) 4.20 Voltage input 0... 5(V), 1... 5(V), 0... 10(V), 2... 10(V), 0... 1 (V) 0.10 Decimal figures 0... 3 0 A-5 A-4 4 SSc Initial scale readout From -1999 to FSC (E.U.) -1999 A-6 5 FSc Final scale readout From SSc to 9999 (E.U.) 9999 A-7 6 0.Pot Offset value (to shift the zero readout) From SSc to Fsc (E.U.) 0 = °C 7 unit Engineering unit °C or °F 0 = °C A-8 FiL Digital filter on the measured value From 0 (oFF) 20.0 (s) 1.0 C-0 8 9 diF1 Digital input 1 function 10 diF2 Digital input 2 function oFF AAC ASi HoLd r.Pic 0.Pot r.PoP t.rHr t.run t.rES t.rH uP.du = No function = Alarm Reset nonE = Alarm acknowledge (ACK) = Hold of the measured value = Peaks reset = Start of the 0.Pot procedure = Start of the 0.Pot proc. and Peaks reset = Timer Run/Hold/Reset [transition] = Timer Run [transition] nonE = Timer reset [transition] = Timer run/hold [Status] = Digital inputs in parallel to and keys A-13 A-14 ] ] Out Group (parameters relative to the outputs) no. Parameter 11 o1F Description Out 1 function Range nonE AL t.out t.HoF or.bo P.FAL bo.PF diF.1 diF.2 12 13 o1AL o1Ac = Output not used. = Alarm output = Timer output = Tiemer out - OFF in Hold = Out-of-range or burn out indicator = Power failure indicator = Out-of-range, burn out and Power failure indicator = The output repeats the digital input 1 status = The output repeats the digital input 2 status Vis. Default Promo. H.reg Alarms linked to output 1 0... 15 +1 = Alarm 1 +2 = Alarm 2 +4 = Alarm 3 +8 = Alarm 4 +16 = Sensor break (burn out) AL1 Out 1 action dir rEU dir.r ReU.r dir = Direct action = Reverse action = Direct with reversed LED = Reverse with reversed LED A-17 C-0 o2F Out 2 function AL 1 A-19 o2AL Alarms linked up with out 2 Same range as [12] o1AL - Alarms linked to output 1 AL1 A-20 16 o2Ac Out 2 action Same range as [13] o1Ac - Out 1 action dir C-0 17 o3F Out 3 function Same range as [11] o1F - Out 1 function AL A-22 18 o3AL Alarms linked up with out 3 Same range as [12] o1AL - Alarms linked to output 1 AL2 A-23 19 o3Ac Out 3 action Same range as [13] o1Ac - Out 1 action dir C-0 20 o4F Out 4 function Same range as [11] o1F - Out 1 function AL A-24 21 o4AL Alarms linked up with out 4 See parameter [12] o1AL - Alarms linked to output 1 AL2 A-25 22 o4Ac Out 4 action dir C-0 ] AL1 Group (parameters relative to AL1 - alarm 1) no. Parameter 23 24 AL1t Ab1 Description Range Alarm 1 type nonE LoAb HiAb LHAb SE.br = Alarm not used = Absolute low alarm = Absolute high alarm = Absolute band alarm = Sensor break Alarm 1 function From 0 to 15 +1 = Not active at power up +2 = Latched alarm (manual reset) +4 = Acknowledgeable alarm LoAb Same range as [24] AB1 - Alarm 1 function 0 C-0 49 AL4L - For High and low alarms, it is the low limit Same range as [25] AL1L - Low limit of the of the AL4 threshold AL1 threshold/How AL1 threshold - For band alarm, it is low alarm threshold -1999 C-0 50 AL4H - For High and low alarms, it is the high Same range as [26] AL1L - High limit of the limit of the AL4 threshold AL1 threshold/High AL1 threshold - For band alarm, it is high alarm threshold 9999 C-0 51 AL4 AL4 threshold From AL4L to AL4H (E.U.) 0 C-0 52 HAL4 AL4 hysteresis From 1... 9999 (E.U.) 1 C-0 53 AL4d AL4 delay From 0 (oFF) to 9999 (s) oFF C-0 Alarm 4 at out of range indication No = Alarm NOT running when out-of-range no YES = Alarm enabled when out-of-range C-0 54 AL4o Tin Group no. Parameter 26 AL1H - For High and low alarms, it is the high limit of the AL1 threshold From AL1L to 9999 ( E.U.) - For band alarm, it is high alarm threshold 9999 A-49 27 AL1 AL1 threshold From AL1L to AL1H (E.U.) 0 A-50 28 HAL1 AL1 hysteresis 1... 9999 (E.U.) 1 A-51 29 AL1d AL1 delay From 0 (oFF) to 9999 (s) oFF C-0 Alarm 1 at out of range indication No = Alarm NOT running when out-of-range no YES = Alarm enabled when out-of-range C-0 tr.F Independent timer function 56 tr.u Timer unit hh.nn = Hours and minutes nn.SS = Minutes and seconds SSS.d = Second and tenth of seconds 57 tr.t1 Time 1 58 tr.t2 Time 2 tr.St Timer status Description Range Description C-0 uSrb = = = = = = = = = = No function Alarm reset Alarm acknowledge Hold of the measured value The display will shows the peaks Peaks reset Start the 0.Pot routine 0.Pot routine + Peaks reset Input calibration with self-learning procedure Timer run/hold/reset nonE A-94 63 diSP Display management nonE AL1 AL2 AL3 ti.uP ti.du = = = = = = Standard display Alarm 1 threshold Alarm 2 threshold Alarm 3 threshold Timer time up Timer time down nonE A-95 64 Edit Alarm editing enable AE AnE = Alarm thresholds can be modified = Alarm threshold can NOT be modified ?? ?? ] AL2L -1999 A-56 no. Parameter 34 AL2H - For High and low alarms, it is the high Same range as [26] AL1L - High limit of the limit of the AL2 threshold AL1 threshold/High AL1 threshold - For band alarm, it is high alarm threshold 9999 A-57 35 AL2 AL2 threshold From AL2L to AL2H (E.U.) 0 A-58 36 HAL2 AL2 hysteresis 1.... 9999 (E.U.) 1 A-59 37 AL2d AL2 delay From 0 (oFF) to 9999 (s) oFF C-0 Alarm 2 at out of range indication No = Alarm NOT running when out-of-range YES = Alarm enabled when out-of-range no C-0 65 Add Address 66 bAud Baud rate ] C-0 ]CAL Group (User calibration) AL2L -1999 C-0 no. Parameter AL2H - For High and low alarms, it is the high Same range as [26] AL1L - High limit of the limit of the AL3 threshold AL1 threshold/High AL1 threshold - For band alarm, it is high alarm threshold 9999 AL3 threshold From AL3L to AL3H (E.U.) 0 HAL2 AL3 hysteresis From 1... 9999 (E.U.) 1 C-0 AL2d AL3 delay From 0 (oFF) to 9999 (s) oFF C-0 46 AL2o Alarm 3 at out of range indication No = Alarm NOT running when out-of-range YES = Alarm enabled when out-of-range no C-0 = Not used = Total worked days = Total worked hours Threshold of the worked hours/days From 0 (oFF) to 9999 (days/hours) 0 45 oFF dAY Hour 68 h.Job Same range as [24] AB1 - Alarm 1 function 44 Vis. Promo. C-0 C-0 Vis. Default Promo. Range Measurement type Alarm 3 function C-0 9600 67 co.ty - For High and low alarms, it is the low limit Same range as [25] AL1L - Low limit of the of the AL3 threshold AL1 threshold/How AL1 threshold - For band alarm, it is low alarm threshold AL2 1 Description Ab3 43 Default CON Group (worked time count) no. Parameter C-0 Range 0 (oFF)... 254 1200 (bit/s) 2400 (bit/s) 9600 (bit/s) 19.2 (kbit/s) 38.4 (kbit/s) Same range as [23] AL1t - Alarm 1 type 40 42 Description Alarm 3 type AL3t 41 SER Group Vis. Default Promo. C-0 LoAb 39 Vis. Default Promo. Range nonE AAc ASi HoLd button function during d.Pic r.Pic run time 0.Pot r.Pot t.Pot Str.t C-0 Range C-0 A-93 0 Description rES 30 Same range as [24] AB1 - Alarm 1 function no. Parameter A-65 3... 999 Alarm 2 function AL3 Group (parameters relative to AL3 - alarm 3) 1.00 From 0 (oFF) to 999 (oFF = Level 2 not protected by psw) 20 - For High and low alarms, it is the low limit Same range as [25] AL1L - Low limit of the of the AL2 threshold AL1 threshold/How AL1threshold - For band alarm, it is low alarm threshold AL2o A-64 Password level 3 Ab2 38 1.00 Password level 2 A-54 33 A-63 PAS3 LoAb 32 nn.SS PAS2 Same range as [23] AL1t - Alarm 1 type AL2t 00.01... 99.59 when tr.u = hh.nn 00.01... 99.59 when tr.u = nn.SS 000.1... 995.9 when tr.u = SSS.d 00.01... 99.59 when tr.u = hh.nn + iNF 00.01... 99.59 when tr.u = nn.SS + iNF 000.1... 995.9 when tr.u = SSS.d + iNF run = timer run HoLd = timer hold rES = timer reset A-62 61 Alarm 2 type 31 = Timer not used = Delayed start timer = Delayed start at power up nonE = Feed-through timer = Asymmetrical oscillator with start in OFF = Asymmetrical oscillator with start in ON Vis. Promo. 60 62 Vis. Default Promo. Default PAN Group AL2 Group (parameters relative to AL2 - alarm 2) no. Parameter Range 55 no. Parameter A-48 ] Description NonE i.d.A i.uP.d i.d.d i.P.L i.L.P ] -1999 ] Same range as [23] AL1t - Alarm 1 type Alarm 4 function A-47 - For High and low alarms, it is the low limit of the AL1 threshold From -1999 to AL1H ( E.U.) - For band alarm, it is low alarm threshold AL1o Alarm 4 type LoAb AL1L Vis. Promo. C-0 Ab4 59 C-0 Default AL4t Vis. Promo. 0 Range 48 Default 25 30 Description 47 ] 15 Same range as [13] o1Ac - Out 1 action no. Parameter A-16 14 Same range as [11] o1F - Out 1 function AL4 Group (parameters relative to AL4 - alarm 4) Description Range nonE A-97 oFF A-100 Vis. Default Promo. 69 A.L.P Adjust low Point From -1999 to AH.P-10 (E.U.) 0 A-9 70 A.L.o Adjust low Offset -300... +300 (E.U.) 0 A-10 71 A.H.P Adjust High Point From A.L.P +10 to 9999 (E.U.) 9999 A-11 72 A.H.o Adjust High Offset -300... +300 (E.U.) 0 A-12 ">
/
பதிவிறக்கு
ஒரு நட்பு நினைவூட்டல். நீங்கள் ஆவணத்தை இங்கே பார்க்கலாம். ஆனால் மிக முக்கியமாக, எங்கள் AI ஏற்கனவே அதைப் படித்துவிட்டது. இது சிக்கலான விஷயங்களை எளிய சொற்களில் விளக்கலாம், உங்கள் கேள்விகளுக்கு எந்த மொழியிலும் பதிலளிக்கலாம், மேலும் மிக நீளமான அல்லது சிக்கலான ஆவணங்களை விரைவாக செல்லவும் உதவும்.
விளம்பரம்